Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016. macle GmbH GRAFENTHAL R2208 S2 Storage system

Similar documents
Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system

Certification Document bluechip STORAGEline R54300s NAS-Server 03/06/2014. bluechip STORAGEline R54300s NAS-Server system

Test Report Newtech Supremacy II NAS 05/31/2012. Newtech Supremacy II NAS storage system

Step-by-Step Guide. to configure Open-E DSS V7 Active-Active iscsi Failover on Intel Server Systems R2224GZ4GC4. Software Version: DSS ver. 7.

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

Fusionstor NAS Enterprise Server and Microsoft Windows Storage Server 2003 competitive performance comparison

LSI MegaRAID CacheCade Performance Evaluation in a Web Server Environment

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

10GbE Ethernet for Transfer Speeds of Over 1150MB/s

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

1000-Channel IP System Architecture for DSS

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

Cisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet

Qsan Document - White Paper. Performance Monitor Case Studies

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC b Test Report Date: 27, April

F600Q 8Gb FC Storage Performance Report Date: 2012/10/30

Linux NIC and iscsi Performance over 40GbE

I/O PERFORMANCE OF THE LENOVO STORAGE N4610

I/O Performance of Cisco UCS M-Series Modular Servers with Cisco UCS M142 Compute Cartridges

Implementing Enterprise Disk Arrays Using Open Source Software. Marc Smith Mott Community College - Flint, MI Merit Member Conference 2012

Appendix 3. Specifications for e-portal

ReadyNAS OS 6 Desktop & Rackmount Performance

Using Synology SSD Technology to Enhance System Performance Synology Inc.

CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS

TS500-E5. Configuration Guide

Pivot3 Reference Architecture for VMware View Version 1.03

StarWind iscsi SAN: Configuring Global Deduplication May 2012

How To Back Up A Computer To A Backup On A Hard Drive On A Microsoft Macbook (Or Ipad) With A Backup From A Flash Drive To A Flash Memory (Or A Flash) On A Flash (Or Macbook) On

Cisco Prime Home 5.0 Minimum System Requirements (Standalone and High Availability)

Performance Report Modular RAID for PRIMERGY

RAID 5 rebuild performance in ProLiant

LSI MegaRAID FastPath Performance Evaluation in a Web Server Environment

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

Cisco Unified Computing System Hardware

Step-by-Step Guide to Open-E DSS V7 Active-Active Load Balanced iscsi HA Cluster

Cisco Unified Computing System and EMC VNXe3300 Unified Storage System

High Performance Tier Implementation Guideline

ADVANCED NETWORK CONFIGURATION GUIDE

Microsoft SharePoint Server 2010

IncidentMonitor Server Specification Datasheet

How To Evaluate Netapp Ethernet Storage System For A Test Drive

SLIDE 1 Previous Next Exit

Step-by-Step Guide to Open-E DSS V7 Active-Active iscsi Failover

napp-it ZFS Storage principles for Video Performance Dual Xeon, 40 GB RAM Intel X540, mtu 9000 (JumboFrames) Server OS: Oracle Solaris 11.3 SMB 2.

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

1. Specifiers may alternately wish to include this specification in the following sections:

AlphaTrust PRONTO - Hardware Requirements

Using Synology SSD Technology to Enhance System Performance. Based on DSM 5.2

SMB Direct for SQL Server and Private Cloud

SYSTEM SETUP FOR SPE PLATFORMS

Building High-Performance iscsi SAN Configurations. An Alacritech and McDATA Technical Note

Synology High Availability (SHA)

Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000

Patriot Hardware and Systems Software Requirements

Microsoft Exchange Server 2003 Deployment Considerations

SEAGATE 600GB 15K 12GBPS SAS 2.5" ENTERPRISE PERFORMANCE HDD/ST600MP0065 SPC-1C V1.5

Mit Soft- & Hardware zum Erfolg. Giuseppe Paletta

Data Communications Hardware Data Communications Storage and Backup Data Communications Servers

Measuring Interface Latencies for SAS, Fibre Channel and iscsi

Introduction to MPIO, MCS, Trunking, and LACP

HP Z Turbo Drive PCIe SSD

Cloud Storage. Parallels. Performance Benchmark Results. White Paper.

D1.2 Network Load Balancing

PSAM, NEC PCIe SSD Appliance for Microsoft SQL Server (Reference Architecture) September 11 th, 2014 NEC Corporation

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

Multiple Public IPs (virtual service IPs) are supported either to cover multiple network segments or to increase network performance.

White paper. QNAP Turbo NAS with SSD Cache

Product Brief. R7A-200 Processor Card. Rev 1.0

Volume Replication INSTALATION GUIDE. Open-E Data Storage Server (DSS )

How To Write An Article On An Hp Appsystem For Spera Hana

HP ProLiant Gen8 vs Gen9 Server Blades on Data Warehouse Workloads

AIX NFS Client Performance Improvements for Databases on NAS

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

Balancing CPU, Storage

Outline. Introduction Virtualization Platform - Hypervisor High-level NAS Functions Applications Supported NAS models

Lab Evaluation of NetApp Hybrid Array with Flash Pool Technology

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Boost Database Performance with the Cisco UCS Storage Accelerator

Volume Performance and Configuration on ReadyDATA Platforms

MedInformatix System Requirements

AirWave 7.7. Server Sizing Guide

HP Proliant BL460c G7

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

IOmark- VDI. Nimbus Data Gemini Test Report: VDI a Test Report Date: 6, September

Overland 2 TB SnapServer 210 NAS Server. Overland 4 TB SnapServer 210 NAS Server Operating System GuardianOS GuardianOS

Analysis: Determining the Impact of Switching on VSAN Performance. Do budget network

Microsoft Private Cloud Fast Track Reference Architecture

Visual UpTime Select Server Specifications

Microsoft SharePoint Server 2010

UCS M-Series Modular Servers

NIVEO Network Attached Storage Series NNAS-D5 NNAS-R4. More information:

StarWind Virtual SAN Best Practices

Seradex White Paper. Focus on these points for optimizing the performance of a Seradex ERP SQL database:

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

Running Microsoft SQL Server 2012 on a Scale-Out File Server Cluster via SMB Direct Connection Solution Utilizing IBM System x Servers

Evaluation Report: Supporting Multiple Workloads with the Lenovo S3200 Storage Array

N5 NETWORKING BEST PRACTICES

EMC ISILON NL-SERIES. Specifications. EMC Isilon NL400. EMC Isilon NL410 ARCHITECTURE

Transcription:

macle GmbH GRAFENTHAL R2208 S2 Storage system

Executive summary After performing all tests, the macle GmbH GRAFENTHAL R2208 S2 has been officially certified according to the Open-E Hardware Certification Program Guide 2.1. During the tests, it was found that the system is functional and efficient. With the Open-E DSS V7 operating system installed, the macle GmbH GRAFENTHAL R2208 S2 is stable and performs well. In general, the system can be used for many different applications, but the following are recommended: Storage for database The following features make the macle GmbH GRAFENTHAL R2208 S2 great storage for databases: Two 1GbE interfaces for database connection. Hardware RAID10 for high performance, best I/Ops ratio and data safety. Eight SSD drives ensure fast random data access and reliability. NAS filer For this application the following can be used: Eight SSD drives provide a good amount of I/OPS for user files access. Hardware RAID5 for fault tolerance and the most efficient use of available disk space or RAID10 for increased IOPS. Two 1GbE interfaces for independent connection to different networks or link aggregation for improved throughput. iscsi storage The following features make macle GmbH GRAFENTHAL R2208 S2 good iscsi storage: Eight SSD drives provide high performance and random data access to storage. Two 1GbE interfaces for fast MPIO connection and flexible network topology. Redundant power supply for system reliability. Certification notes For link aggregation, it is recommended to use balance-alb bonding mode. 2

macle GmbH GRAFENTHAL R2208 S2 hardware components... 4 macle GmbH GRAFENTHAL R2208 S2 photos... 5 Auxiliary systems hardware components... 6 Administration functionality... 7 Network functionality... 8 Network test topology... 8 802.3ad bonding mode test... 9 Balance-alb bonding mode test... 10 Balance-rr bonding mode test... 11 Single NIC performance test... 12 RAID functionality... 13 RAID test topology... 13 Hardware RAID0 test... 14 Hardware RAID1 test... 15 Hardware RAID5 test... 16 Hardware RAID10 test... 17 NAS functionality... 18 NAS test topology... 18 SMB test... 19 iscsi functionality... 20 iscsi Initiator test topology... 20 iscsi Target test topology... 20 iscsi Initiator test... 21 iscsi Target test... 22 3

macle GmbH GRAFENTHAL R2208 S2 hardware components Technical specifications about the certified system are listed below: Model macle GmbH GRAFENTHAL R2208 S2 Operating system Open-E DSS V7 build 16323 Enclosure/chassis Grafenthal R2208 S2 CPU Intel Xeon Processor E5-2620 v3 2.40GHz Motherboard Inspur M3250 Memory 2x 8GB Crucial CT8G4RFS4213 DDR4 ECC REG Network Intel Ethernet Controller I350-AM2 HW RAID LSI MegaRaid SAS 9361-8i Hard disk drives 8x 256GB Toshiba THNSNJ256GCSU TABLE 1: Hardware components list of Certified System with Open-E DSS V7 4

macle GmbH GRAFENTHAL R2208 S2 photos FIGURE 1: Front photo FIGURE 2: Rear photo FIGURE 3: Top photo 5

Auxiliary systems hardware components Auxiliary systems with MS Windows or Open-E DSS V7 installed, used in Open-E Hardware Certification Process. Model Operating system Enclosure/chassis Motherboard CPU Memory Network Hard disk drives macle GmbH GRAFENTHAL T1004 MS Windows Server 2012 R2 GRAFENTHAL Compact Performance Server ASROCK E3C226D2I Intel Xeon Processor E3-1220 V3 3.10GHz 8GB Crucial CT8G4RFS4213 DDR4 ECC REG 2x Intel Ethernet Controller I210-AT 1TB HGST HTS721010A9E630 TABLE 2: Hardware components of first Workstation with MS Windows Model Operating system Enclosure/chassis Motherboard CPU Memory Network Hard disk drives macle GmbH GRAFENTHAL T1004 MS Windows Server 2012 R2 GRAFENTHAL Compact Performance Server ASROCK E3C226D2I Intel Xeon Processor E3-1220 V3 3.10GHz 8GB Crucial CT8G4RFS4213 DDR4 ECC REG 2x Intel Ethernet Controller I210-AT 1TB HGST HTS721010A9E630 TABLE 3: Hardware components of second Workstation with MS Windows Model macle GmbH GRAFENTHAL R2208 S2 Operating system Open-E DSS V7 build 16323 Enclosure/chassis Grafenthal R2208 S2 CPU Intel Xeon Processor E5-2620 v3 2.40GHz Motherboard Inspur M3250 Memory 2x 8GB Crucial CT8G4RFS4213 DDR4 ECC REG Network Intel Ethernet Controller I350-AM2 HW RAID LSI MegaRaid SAS 9361-8i Hard disk drives 8x 256GB Toshiba THNSNJ256GCSU TABLE 4: Hardware components of Workstation with Open-E DSS V7 6

Model Description Netgear ProSafe Plus XS708E 8x 100/1000/10000 Mbps ports with 1 combo port supporting 10GbE SFP TABLE 5: Network switch details for connection with 1GbE Administration functionality The following functionality has been tested. Drive identifier Power button Front and rear LEDs OK OK OK TABLE 6: Administration functionality test results 7

Network functionality Tests performed in this section check the functionality, performance and stability of the network solutions available in the Open-E DSS V7 product on the certified system. The tests rely on configuring the iscsi targets and copying the data from many Workstations with MS Windows through various network connections with big block size using appropriate testing tools. Network test topology Network topology for Network testing is shown below. FIGURE 4: Network topology for Network testing 8

802.3ad bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through an 802.3ad bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for 802.3ad bonding mode test performed on Intel Ethernet Controller I350-AM2 802.3ad bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM2 Write speed Read speed Performance test results 1 st Workstation 58.61 60.77 passed 2 nd Workstation 56.00 61.26 passed TABLE 7: 802.3ad bonding mode performance test results table for Intel Ethernet Controller I350-AM2 1st Workstation 2nd Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 5: 802.3ad bonding mode performance test results chart for Intel Ethernet Controller I350-AM2 9

Balance-alb bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-alb bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for Balance-alb bonding mode test performed on Intel Ethernet Controller I350-AM2 Balance-alb bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM2 Write speed Read speed Performance test results 1 st Workstation 112.96 112.90 passed 2 nd Workstation 112.99 112.92 passed TABLE 8: Balance-alb bonding mode performance test results table for Intel Ethernet Controller I350-AM2 1st Workstation 2nd Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 6: Balance-alb bonding mode performance test results chart for Intel Ethernet Controller I350-AM2 10

Balance-rr bonding mode test 1. Test description The test relies on configuring the iscsi targets and copying the data from many Workstations with MS Windows through a Balance-rr bonding mode network connection with a 4MB block size using the Iometer testing tool. 2. Test results for Balance-rr bonding mode test performed on Intel Ethernet Controller I350-AM2 Balance-rr bonding mode performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM2 Write speed Read speed Performance test results 1 st Workstation 54.68 102.87 passed 2 nd Workstation 53.77 99.95 passed TABLE 9: Balance-rr bonding mode performance test results table for Intel Ethernet Controller I350-AM2 1st Workstation 2nd Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 7: Balance-rr bonding mode performance test results chart for Intel Ethernet Controller I350-AM2 11

Single NIC performance test 1. Test description The test relies on configuring the iscsi targets and copying the data from Workstations with MS Windows through single NIC with a 4MB block size using the Iometer testing tool. 2. Test results for single NIC test performed on Intel Ethernet Controller I350-AM2 Single NIC performance test results NIC model Workstations with MS Windows Intel Ethernet Controller I350-AM2 Write speed Read speed Performance test results 1 st Workstation 112.99 112.89 passed TABLE 10: Single NIC performance test results table for Intel Ethernet Controller I350-AM2 1st Workstation Write speed Read speed 0 20 40 60 80 100 120 FIGURE 8: Single NIC performance test results chart for Intel Ethernet Controller I350-AM2 12

RAID functionality Tests performed in this section check the functionality, performance and stability of Open-E DSS V7 storage devices on the certified system. Tests in this section rely on the creation of the RAID units on 0, 1, 5, and 10 levels, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. RAID test topology Network test topology for RAID testing is shown below FIGURE 9: Network test topology for RAID testing 13

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 Hardware RAID0 test 1. Test description The test relies on creation of the RAID0 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for RAID0 and Intel Ethernet Controller I350-AM2 RAID0 performance test results Block size [KB] Write speed Read speed Performance test results 4 36.29 36.19 passed 32 112.75 112.66 passed 64 112.95 112.90 passed 128 112.96 112.91 passed 256 112.99 112.91 passed 512 112.98 112.92 passed 1024 112.98 112.90 passed 4096 112.93 112.84 passed TABLE 11: RAID0 performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 10: RAID0 performance test results chart for Intel Ethernet Controller I350-AM2 14

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 Hardware RAID1 test 1. Test description The test relies on creation of the RAID1 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for RAID1 and Intel Ethernet Controller I350-AM2 RAID1 performance test results Block size [KB] Write speed Read speed Performance test results 4 44.76 36.77 passed 32 112.74 112.41 passed 64 112.96 112.70 passed 128 112.96 112.74 passed 256 113.00 112.75 passed 512 112.99 112.73 passed 1024 112.98 112.79 passed 4096 112.90 112.73 passed TABLE 12: RAID1 performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 11: RAID1 performance test results chart for Intel Ethernet Controller I350-AM2 15

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 Hardware RAID5 test 1. Test description The test relies on creation of the RAID5 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for RAID5 and Intel Ethernet Controller I350-AM2 RAID5 performance test results Block size [KB] Write speed Read speed Performance test results 4 41.44 37.54 passed 32 112.75 112.51 passed 64 112.96 112.77 passed 128 112.96 112.84 passed 256 113.00 112.86 passed 512 112.99 112.89 passed 1024 112.98 112.88 passed 4096 112.93 112.84 passed TABLE 13: RAID5 performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 12: RAID5 performance test results chart for Intel Ethernet Controller I350-AM2 16

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 Hardware RAID10 test 1. Test description The test relies on creation of the RAID10 unit on all hard disk drives, configuring the iscsi target and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for RAID10 and Intel Ethernet Controller I350-AM2 RAID10 performance test results Block size [KB] Write speed Read speed Performance test results 4 36.07 37.14 passed 32 112.70 112.67 passed 64 112.96 112.91 passed 128 112.96 112.92 passed 256 113.00 112.85 passed 512 112.99 112.95 passed 1024 112.98 112.92 passed 4096 112.90 112.88 passed TABLE 14: RAID10 performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 13: RAID10 performance test results chart for Intel Ethernet Controller I350-AM2 17

NAS functionality Tests performed in this section check the functionality, performance and stability of the NAS protocols in the Open-E DSS V7 product on the certified system. The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. NAS test topology Network topology for NAS testing is shown below. FIGURE 14: Network topology for NAS testing 18

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 SMB test 1. Test description The tests rely on creating NAS shares and copying the data from a Workstation with MS Windows via network connection with various block sizes using the Iometer testing tool. 2. Test results for SMB and Intel Ethernet Controller I350-AM2 SMB performance test results Block size [KB] Write speed Read speed Performance test results 4 63.35 63.58 passed 32 112.65 112.68 passed 64 112.90 104.24 passed 128 112.82 110.96 passed 256 112.85 112.77 passed 512 112.88 112.78 passed 1024 112.88 112.66 passed 4096 112.79 112.76 passed TABLE 15: SMB performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 15: SMB performance test results chart for Intel Ethernet Controller I350-AM2 19

iscsi functionality Tests performed in this section check the functionality, performance and stability of the iscsi protocol in the Open-E DSS V7 product on the certified system. iscsi Initiator test topology Network topology for iscsi Initiator testing is shown below. FIGURE 16: Network topology for iscsi Initiator testing iscsi Target test topology Network topology for iscsi Target testing is shown below. FIGURE 17: Network topology for iscsi Target testing 20

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 iscsi Initiator test 1. Test description The test relies on using the storage connected via the built-in iscsi Initiator for NAS volumes, creating SMB shares on these NAS volumes and copying data from a Workstation with MS Windows to them with various block sizes using the Iometer testing tool. 2. Test results for iscsi Initiator and Intel Ethernet Controller I350-AM2 iscsi Initiator performance test results Block size [KB] Write speed Read speed Performance test results 4 43.35 36.62 passed 32 112.75 112.65 passed 64 112.96 112.90 passed 128 112.96 112.91 passed 256 113.00 112.91 passed 512 112.99 112.92 passed 1024 112.98 112.90 passed 4096 112.90 112.84 passed TABLE 16: iscsi Initiator performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 18: iscsi Initiator performance test results chart for Intel Ethernet Controller I350-AM2 21

Block size [KB] Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016 iscsi Target test 1. Test description The test relies on creating the iscsi target on the certified system and copying the data from a Workstation with MS Windows to it with various block sizes using the Iometer tool. 2. Test results for iscsi Target and Intel Ethernet Controller I350-AM2 iscsi Target performance test results Block size [KB] Write speed Read speed Performance test results 4 63.31 63.66 passed 32 112.66 112.69 passed 64 112.90 107.90 passed 128 112.84 110.22 passed 256 112.85 112.77 passed 512 112.87 112.79 passed 1024 112.89 112.36 passed 4096 112.84 112.79 passed TABLE 17: iscsi Target performance test results table for Intel Ethernet Controller I350-AM2 4 32 64 128 256 512 1024 4096 Write speed Read speed 0 20 40 60 80 100 120 FIGURE 19: iscsi Target performance test results chart for Intel Ethernet Controller I350-AM2 22