USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018



Similar documents
User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Online UPS. PowerWalker VFI 1000R/1U

Powerware 5110 UPS User s manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

User Manual 1K/2K/3K Online UPS

USER MANUAL Online UPS 1K/2K/3K Rack

350, 500, 650 and 1000 MODELS

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

USER MANUAL Online UPS 1K/2K/3K

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

10000HXL31/15000HXL31/20000HXL31

How To Use A Power Supply Unit (Upland)

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

SPL 2-00/-01 OPERATION INSTRUCTIONS

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

HP UPS R1500 Generation 3

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

3000W Power Inverter

Residential Gateway (RG) Battery Backup

Installation and Operating Instructions (for chargers shown below)

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Home Solar Kit Owner s Manual. Model: HS

Installation and Operating Instructions (for chargers shown below)

Installation and Operation Back-UPS 1250, 1300, 1500

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

EKOS Cart. Instructions for Use

Operating Guide Manuel de l utilisateur

Advantium 2 Plus Alarm

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Dehumidifier Users manual. For Models: DH45S DH65S

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

esata External Storage

BroadBand PowerShield. User Manual

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Achat 115MA full-range speaker. user manual

Manual for Fire Suppression & Methane Detection System

User Manual for CH-PFC76810

User s Manual Before using the inverter, you need to read and save the safety instructions.

BITMAIN. APW PSU Series User Guide

Uninterruptible Power Supply

Wine Cooler with Thermo-Electric Cooling & Heating Technology

LOXONE 12 Channel Amplifier

ADM1TE 5/30A DIN rail single phase two wire energy meter

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Li Battery Pack & Charger Safety & Operating Instructions

2013 VTech Printed in China US

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

=============================== WARNING

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Back-UPS Pro 1300/1500 Installation and Operation

Single Day Alarm Clock with. Bluetooth and USB Play-through

VLT Series 300 Watt True Sine Wave Inverter

Model 1756 Test Lead Kit

400 Amp Rechargeable Jump Start System RAC-HP082

ST Series POWER SUPPLIES USER INSTRUCTIONS

AIR-CONDITIONER SPLIT TYPE

HM-W536 Install Guide

Model 70A00-1. GSM Cellular Communications Center

TIG INVERTER INSTRUCTION MANUAL

Operating Instructions

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Congratulations! Thank you!

TMS TANK MANAGEMENT SYSTEM

Indoor Remote Controlled Power Points

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

UPS-2200R-HH/UPS-2200R-HHIP

Fire Alarm Control Panel. Family. Operating Manual

USER MANUAL Online UPS 6K/10K RACK

Spec. No. ICR C Version No. 0.0

±15 V Current-Limited Power Supply

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Operating Instructions

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Home Solar Kit Owner s Manual. Model: HS

CHARGING SYSTEMS INTERNATIONAL

Installation Instructions for Alarm Module Kit A043F059

YSmart Technology Co.,Ltd

Instructional & Operating Manual

Transcription:

USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and MaxPower 600 that should be followed during installation and maintenance of the UPS and batteries.

Safety CAUTION! This product is specially designed for PCs and it is not recommended for use in any life-supporting system and other specific important equipment. This equipment can be operated by any individual with no previous training. Do not plug household appliances such as hair dryers to UPS receptacles. This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. CAUTION: Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. The utility power outlet shall be near the equipment and easily accessible. To isolate UPS from AC input, remove the plug from the utility power outlet. If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the utility power to UPS, switch ON ), once a month for 24 hours to avoid a full battery discharge. Please do not use the UPS in excess of the rated load capacity. The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is required, please contact the distributor. The internal short circuiting of the UPS will lead to dangers such as electric shock or fire, therefore, no water containers (such as a water glass) shall be placed on the top of the UPS so as to avoid such dangers as electric shock. Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. on the rating label stands for phase symbol. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries : 1) Remove watches, rings, or other metal objects from the hand. 2) Use tools with insulated handles.

Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same type and number of the sealed lead-acid batteries. The maximum ambient temperature rating is 40. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. In case smoke is found coming out from the device, please cut off the power supply quickly and contact the distributor. Do not keep or use this product in any of the following environments: Any area with combustible gas, corrosive substance or heavy dust. Any area with extraordinarily high or low temperature (above 40 C or below 0 C) and humidity of more than 90%. Any area exposed to direct sunshine or near any heating apparatus. Any area with serious vibrations. Outdoor. In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use of liquid extinguishers may give rise to the danger of electric shock.

1. System Description Front panel: 1. Power Switch 2. UPS status Indicator AC Mode: Green lighting Battery Mode: Green flashing 3. Fault LED: Red flashing Back Panel 1. Output receptacles 2. Fuse 3. AC Input with AC fuse 4. AC Input 5 Modem/Phone Line Surge Protection (Option)

2. Installation and operation 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 10 hours with no load (no electrical devices such as computers, monitors, etc.) connected. 3. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high.

4. Computer Connection Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. 5. Modem/Phone Line Connection Plug incoming internet line into the In socket at the back of the UPS. Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS. Plug the other end to the modem input socket as shown. Incoming Internet Line 6. Turn On/Off Press the switch of the UPS continuously for 1 second and the UPS turns into its normal state (the green light is on and the beeper is off) after it performs a self-diagnosis (the beeper and the red and green indicator lights are on) for several seconds. At this time, user may turn on the PC and other loads. Press the switch of the UPS continuously for 1 second to turn off the UPS. Note: 1. For the convenience of maintenance, please turn on the UPS first before turning on the PC and the other loads, and turn off the UPS after the loads are turned off. 2. At ordinary times, we recommend to remain the UPS on with the battery charging (even if the loads are turned off), which is benefit to the maintenance of the battery.

3. Trouble Shooting Symptom Possible Cause Remedy No LED display 1. Battery Weak on the front 1. Re-charge battery up to 8 hours. panel. 2. Battery defect. 2. Replace with the same type of battery. 3. Power switch is not 3. Press power switch again. When power failure, backup time is short. pressed. 4. Battery connector loosed 4. Check the internal battery connection 1. Overload of the UPS. 1. Remove some non-critical load. 2. Battery voltage is too low. 2. Charge battery 8 hours or more. 3. Battery defect due to high temperature operation environment, or improper operation to battery. 3. Replace with the same type of battery. Mains normal but LED is flashing. 1. Fuse is blown. 2. Power cord is loose. 1. Replace the same type of fuse. 2. Reconnect the power cord properly. If any abnormal situations occur that are not listed above, please call service people immediately.

4. Specification MODEL MaxPower 400 MaxPower 600 CAPACITY VA/W 400VA/200W 600VA/300W INPUT Voltage 110/120VAC or 220/230/240VAC Voltage Range 90-145VAC / 170-280VAC OUTPUT Voltage 110/120VAC or 220/230/240VAC Voltage Regulation (Batt. Mode) ±10% Frequency 50Hz/60Hz Frequency Regulation (Batt. Mode) +/-1 Hz Output Waveform (Batt. Mode) Modified Sinewave BATTERY Battery Type & Number 12V/4.5Ah x 1pc 12V/7AH x 1pc Back up Time (at a PC load with 15" monitor) 6 9 minutes 13-20 minutes Recharge Time 10 hours to 90% after complete discharge TRANSFER TIME Typical 2-6ms, 12ms max INDICATOR AC Mode Green LED lighting Battery Mode Green LED flashing every 4 seconds Low Battery at Battery Mode Green LED flashing every second Fault Red LED lighting Battery Weak at AC Mode Red LED flashing every 2 seconds for 30 seconds Battery Fault at AC Mode Red LED flashing three times every 2 seconds AUDIBLE ALARM Battery Mode Sounding every 4 seconds Low Battery at Battery Mode Sounding every second Fault Continuously sounding Battery Weak at AC Mode Sounding every 2 seconds for 30 seconds Battery Fault at AC Mode Sounding three times every 2 seconds PROTECTION Full Protection Discharge, overcharge PHYSICAL Dimension, DXWXH (mm) 176.5x80x230 Net Weight (kgs) 2.5 3.1 ENVIRONMENT Operating Environment 0-40 C, 0-90 % relative humidity (non-condensing) Noise Level Less than 45dB