Midland Combustion Electric Line Heaters with Integral Panels



Similar documents
HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

HEAVY DUTY STORAGE GAS

Pressure regulating valve with modulating kit, type DRV


The Yachtmans Choice...

Oil and Coolant Circulating Heating System. Model - OCSM

INTEC Engineering GmbH Heating Solutions for the Marine Industry

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Electric Flow Boiler

Condensate water pump with neutralisation system

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

VAD. Variable Area Desuperheaters

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Drayton Digistat +2RF/+3RF

HFS and HFD Series. High Flow Single and Duplex Filters Max l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Engineered Solutions

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

VAD Variable Area Desuperheaters

SECTION MORTUARY REFRIGERATORS

MANTA Piston Distributor for Oil and Fluid Grease

Conlift1, Conlift2, Conlift2 ph+

Overheating limit control

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

1300 MAXTRAK SPECIFICATION

HL Series - Commercial Heaters Tankless Water Heating Solutions

Please also see 10 golden rules for correct Saniflo installation on

Flex separation systems, S-separators

The space saving solution.

Commercial Electric Water Heater

Screw Plug Immersion Heaters

Explosion-Proof Electric Unit Heaters

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

ELECTRIC CENTRAL HEATING FLOW BOILER

Automatic Self-Cleaning Strainers

Air Conditioner Water Heater Model ACWH18

Light Duty Commercial Electric Water Heater

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Arapahoe County Residential Water Heater Installation and Inspection Guide

Problem / Solution. The problem:

Installation & User Instructions

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Rotary screw compressors kw 5,5 7, , bar MODULO

Cooling Capacity CFM in. w.c. (125 Pa)

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

Oil, Gas and Dual Fuel Burners

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

SIOUX HYBRID WATER HEATER

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Marine Generating Sets 3.7 to 50 kva

3/2-way Solenoid Valve, direct-acting, NC or NO

Assisted lift operated 2/2-way solenoid valves Type EV250B

ECOCIAT. Domestic hot water heat recovery unit

How To Use A Flowmeter

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Commercial Electric Water Heater

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

FLASH TANK ECONOMIZER PRODUCT GUIDE

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Single- and Multi-circuit Pumps

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Oil - kerosene burners

TRANSLATION OF THE ORIGINAL MANUAL

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Commando Technical. plugs 16 and 32 amp. plugs 63 amp. plugs elv. wiring devices ingress protected C A

1. Description. 2. List of Accessories included A B C F G H

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Float and Thermostatic Traps Series H, C and X

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

G234X-55 Conventional Gas Boiler

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Industrial infrared heater IR For premises with large volumes and high ceilings

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

The kva RAnge

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Marine Boilers. From a world class boiler manufacturer

Electric Water Heater

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Transcription:

Midcom Electric Line Heaters are available to work with even the most difficult oils and process fluids when there is no other heating medium available. High viscosity crude oils as well as coal tar, bitumen, mineral oils, water and a host of process fluids can be heated to specific temperatures and controlled precisely either by traditional thermostat or the more up to date method of solid state electronic control offering more accurate temperature control and power saving. Long life low watts density removable ceramic core elements are designed for optimum trouble free service and ease of maintenance. All Midcom Horizontal Line Heaters from ELW range are fitted with adjustable temperature control thermostat and over temperature cut out thermostat. Depending on how the heating load is arranged multiple heating banks with multiple thermostats are designed for efficient heater control fitted into pockets and located within a weather tight enclosure. They are extensively used in small and large heating applications such as Diesel Engine Installations, light oil systems where there is a need to prevent waxing at low temperatures, combustion systems, furnace applications, all styles of heavy fuel oil ring main/power boiler systems where accurate temperature control is needed. With subtle design changes the heaters can be used for the heating of BIO Fuels, Animal fats, Waste oils and for heating process water. All heaters are compliant with European Legislation covering CE markings/ped approval with the basic design complying with PD5500 and/or ASME. The first design pressure range is 11.67 barg but heaters as high as 70 barg are designed and supplied for specific process conditions. One advantage of the Midcom Electric Line Heater is that a failed electric element can be replaced without the need to isolate and drain the heater. All heaters in the Midcom range have been supplied for Marine applications requiring rigorous inspections for the like of Lloyds Register of Shipping, Zurich, ABS etc. Electric Heaters as large as 2000kW have been supplied and packaged with Electric Control Gear by Midcom. Products are hydraulic and electrical tested before they leave the factory. Midland Combustion Limited Station Works, Four Ashes, Wolverhampton WV10 7BX, UK Tel: +44 (0)1902 790541 Fax: +44 (0) 791526 e.mail: sales@mid-com.co.uk - www.mid-com.co.uk

Midcom Load for Rating for Rating for Maximum Heating Code Heavy Fuel Oils Lubricating Oils Waste Oils Capacity for HFO. Through 45ºC kw kw kw kg / hr ELW 4-18 2.7 2.7 1.35 107 ELW 4-24 3.6 3.6 1.8 143 ELW 4-30 4.5 4.5 2.25 178 ELW 4-36 5.4 5.4 2.7 214 ELW 4-42 6.3 6.3 3.15 250 ELW 4-48 7.2 7.2 3.6 285 ELW 4-60 9.0 9.0 4.5 356 ELW 4-72 10.8 10.8 5.4 428 ELW 4-84 12.6 12.6 6.3 499 ELW 4-96 14.4 14.4 7.2 570 ELW 6-24 10.8 8.1 5.4 745 ELW 6-30 13.5 10.125 6.75 535 ELW 6-42 18.9 14.175 9.45 749 ELW 6-48 21.6 16.2 10.8 855 ELW 6-60 27.0 20.25 13.5 1069 ELW 6-72 32.4 24.3 16.2 1283 ELW 6-84 37.8 28.35 18.9 1497 ELW 6-96 43.2 32.4 21.6 1711

Midcom Load for Rating for Rating for Maximum Heating Code Heavy Fuel Oils Lubricating Oils Waste Oils Capacity for HFO. Through 45ºC kw kw kw kg / hr ELW 8-30 22.5 16.88 11.25 891 ELW 8-36 27.0 20.25 13.5 1069 ELW 8-42 31.5 23.63 15.75 1248 ELW 8-48 36.0 27.0 18.0 1426 ELW 8-60 45.0 33.75 22.5 1782 ELW 8-72 54.0 40.5 27.0 2139 ELW 8-84 63.0 47.25 31.5 2495 ELW 8-96 72.0 54.0 36.0 2851 ELW 10-36 48.6 36.45 24.3 1925 ELW 10-42 56.7 42.525 28.35 2246 ELW 10-48 64.8 48.6 32.4 2566 ELW 10-60 81.0 60.75 40.5 3208 ELW 10-72 97.2 72.9 48.6 3850 ELW 10-84 113.4 85.05 56.7 4491 ELW 10-96 129.6 97.2 64.8 5133 ELW 12-42 75.6 65.7 37.8 2994 ELW 12-48 86.4 64.8 43.2 3422 ELW 12-54 97.2 72.9 48.6 3850 ELW 12-60 108.0 81.0 54.0 4277 ELW 12-72 129.6 97.2 64.8 5133 ELW 12-84 151.2 113.4 75.6 5988 ELW 12-96 172.8 129.6 86.4 6844

Midland Combustion Electric Line Heater Dimensions M Flanged Inlet Control Wiring Conduit Entry Int/External Earth Stud Power Wiring Conduit Entry J A D Dia M Flanged Outlet B C L K Electric Element Withdrawal Distance (Dim A) 3/8'' BSPF for Pressure Relief Valve 1/2'' BSPF Drain (Plugged) 2 Holes 14ø in Each Leg H G E F End Elevation Elevation End Elevation Note: Standard heater flanged terminal connections can be supplied with either ANSI B16.5 CL.150 or BS EN 1092:1 2001 PN16 Customer to specify when ordering. Midcom mm mm mm mm mm mm Min mm Min mm NB Code D E F G H J K L M ELW 4 204 200 180 100 70 95 65 160 40 ELW 6 259 240 230 100 70 100 70 160 40 ELW 8 324 280 255 150 110 100 70 160 40 ELW 10 384 325 300 200 150 110 80 160 50 ELW 12 424 350 330 250 200 110 80 160 50 ins ins ins ins ins ins ins ins ins ins Length 18 24 30 36 42 48 60 72 84 96 mm mm mm mm mm mm mm mm mm mm A 500 650 805 955 1110 1260 1565 1870 2175 2480 B 200 320 475 465 620 770 935 1240 1385 1690 C 135 150 150 230 230 230 300 300 380 380

Midland Combustion Electric Line Heater 400 V 3 PH 50HZ 3 Wire 1 2 3 E 1 3 CF1 32/2A 10 11 TX1 400V 150VA 110V 12 13 CF3 20/2A CF2 32/2A LK1 C1 A1 BN B1 C1 GY BK Electrical Wiring Diagram Shown as one heating bank. Multi-bank available. 14 15 Line Heater 14 IL1 W C1 16 IL2 G IL3 18 14 SW1 A Off 2 CS1 14 XS1 Control 19 A1 C1 On 3 1 3 1 A2 Supply On Line Heater On Line Heater Overtemp Line Heater Contactor Last Wire No.19 2 1 3 5 4 Door Layout for Electric Line Heater IP65 Control Panel 1. Supply On Light (IL1) 2. Line Heater On Light (IL2) 3. Line Heater Overtemp Light (IL3) 4. Line Heater Off/On Selector Switch 5. Fuse Switch Handle