Upgrading VMware Identity Manager Connector



Similar documents
Upgrading Horizon Workspace

Reconfiguring VMware vsphere Update Manager

VMware Identity Manager Connector Installation and Configuration

Reconfiguration of VMware vcenter Update Manager

Reconfiguring VMware vsphere Update Manager

Installing and Configuring vcloud Connector

vrealize Air Compliance OVA Installation and Deployment Guide

VMware Identity Manager Administration

Active Directory Solution 1.0 Guide

Installing and Configuring vcenter Support Assistant

Installing and Configuring vcenter Multi-Hypervisor Manager

vsphere Upgrade vsphere 6.0 EN

VMware Identity Manager Administration

VMware vcenter Log Insight Getting Started Guide

Installing and Administering VMware vsphere Update Manager

Management Pack for vrealize Infrastructure Navigator

VMware Software Manager - Download Service User's Guide

Migrating to vcloud Automation Center 6.1

Installing and Configuring vcloud Connector

Managing Multi-Hypervisor Environments with vcenter Server

vsphere Replication for Disaster Recovery to Cloud

VMware vcenter Support Assistant 5.1.1

VMware vcenter Update Manager Administration Guide

vsphere Upgrade Update 1 ESXi 6.0 vcenter Server 6.0 EN

vsphere Replication for Disaster Recovery to Cloud

Setting Up Resources in VMware Identity Manager

Installing and Configuring VMware Workspace Portal

Getting Started with ESXi Embedded

vcenter Configuration Manager Backup and Disaster Recovery Guide VCM 5.3

VMware Mirage Web Manager Guide

VMware vcloud Air - Disaster Recovery User's Guide

VMware vcenter Configuration Manager Backup and Disaster Recovery Guide vcenter Configuration Manager 5.4.1

vrealize Operations Manager Customization and Administration Guide

Offline Data Transfer to VMWare vcloud Hybrid Service

VMware Data Recovery. Administrator's Guide EN

vsphere App HA Installation and Configuration Guide

Virtual Appliance Setup Guide

Request Manager Installation and Configuration Guide

vcloud Director User's Guide

vcenter Chargeback User s Guide

ACE Management Server Deployment Guide VMware ACE 2.0

ESX 4 Patch Management Guide ESX 4.0

VMware vcenter Log Insight Security Guide

Configuring Multiple ACE Management Servers VMware ACE 2.0

Using the vcenter Orchestrator Plug-In for vsphere Auto Deploy 1.0

VMware vcenter Log Insight Security Guide

VMware Horizon FLEX User Guide

Scenarios for Setting Up SSL Certificates for View

vcenter Operations Manager for Horizon Supplement

VMware Horizon FLEX User Guide

OnCommand Performance Manager 1.1

Administering View Cloud Pod Architecture

VMware vcenter Operations Standard Installation and Administration Guide

VMware vcenter Log Insight Getting Started Guide

Deploying Dell OpenManage Server Administrator on VMware ESXi Using Dell Online Depot and VMware Update Manager

VMware Horizon FLEX User Guide

VMware vcenter Update Manager Administration Guide

VMware vrealize Operations for Horizon Administration

VMware vrealize Operations for Horizon Security

VMware vcenter Log Insight Administration Guide

vcloud Suite Licensing

VMware vrealize Operations for Horizon Security

Installing and Configuring VMware Identity Manager

Obtaining SSL Certificates for VMware View Servers

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright Palo Alto Networks

VMware vcenter Configuration Manager Backup and Disaster Recovery Guide vcenter Configuration Manager 5.7

vcenter CapacityIQ Installation Guide

Virtual Managment Appliance Setup Guide

vcenter Support Assistant User's Guide

Integrating VMware Horizon Workspace and VMware Horizon View TECHNICAL WHITE PAPER

Specops Command. Installation Guide

VMware vsphere Data Protection Evaluation Guide REVISED APRIL 2015

Using the vcenter Orchestrator Plug-In for Microsoft Active Directory

F-Secure Messaging Security Gateway. Deployment Guide


vsphere Host Profiles

vcloud Automation Center Self-Service Portal Guide

VMware vsphere 5.0 Evaluation Guide

Virtual Web Appliance Setup Guide

Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1

VMware vcenter Operations Manager for Horizon Supplement

ACE Management Server Administrator s Manual VMware ACE 2.6

Obtaining SSL Certificates for VMware Horizon View Servers

VMware vcenter Discovered Machines Import Tool User's Guide Version for vcenter Configuration Manager 5.3

EMC Documentum Connector for Microsoft SharePoint

Configuring Single Sign-On from the VMware Identity Manager Service to Office 365

VMTurbo Operations Manager 4.5 Installing and Updating Operations Manager

vcenter Chargeback User s Guide vcenter Chargeback 1.0 EN

Setting Up a Unisphere Management Station for the VNX Series P/N Revision A01 January 5, 2010

VMware vcenter Operations Manager Administration Guide

How To Configure A Bomgar.Com To Authenticate To A Rdius Server For Multi Factor Authentication

Virtual Appliance Setup Guide

Copyright 2012 Trend Micro Incorporated. All rights reserved.

VMware vcloud Air Networking Guide

Advanced Service Design

Installation Guide. . All right reserved. For more information about Specops Inventory and other Specops products, visit

Installation and Configuration Guide

DocuShare Installation Guide

SOA Software API Gateway Appliance 7.1.x Administration Guide

Transcription:

Upgrading VMware Identity Manager Connector VMware Identity Manager This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document, see http://www.vmware.com/support/pubs. EN-001881-04

You can find the most up-to-date technical documentation on the VMware Web site at: http://www.vmware.com/support/ The VMware Web site also provides the latest product updates. If you have comments about this documentation, submit your feedback to: docfeedback@vmware.com Copyright 2015, 2016 VMware, Inc. All rights reserved. Copyright and trademark information. VMware, Inc. 3401 Hillview Ave. Palo Alto, CA 94304 www.vmware.com 2 VMware, Inc.

Contents Upgrading VMware Identity Manager Connector 5 1 About Upgrading VMware Identity Manager Connector 7 2 Preparing to Upgrade VMware Identity Manager Connector 9 Prerequisites for Upgrade 9 Check for the Availability of a VMware Identity Manager Connector Upgrade Online 10 Configure Proxy Server Settings for the VMware Identity Manager Connector Appliance 10 3 Performing an Online Upgrade of VMware Identity Manager Connector 11 4 Performing an Offline Upgrade of VMware Identity Manager Connector 13 Prepare a Local Web Server for Offline Upgrade 13 Configure the Connector and Perform Offline Upgrade 13 5 Configure Settings after Upgrading Connector 15 6 Troubleshooting Upgrade Errors 17 Checking the Upgrade Error Logs 17 Rolling Back to Snapshots of Connector 17 Collecting a Log File Bundle 18 Index 19 VMware, Inc. 3

4 VMware, Inc.

Upgrading VMware Identity Manager Connector describes how to upgrade your VMware Identity Manager Connector instance. If you would prefer to do a fresh installation, see VMware Identity Manager Connector Installation and Configuration. Remember that a new installation does not preserve your existing configurations. The following upgrade paths are supported: From version 2.3, 2.4, 2015.10.1, or later to the latest version available For information about using your updated connector instance, see the VMware Identity Manager Administrator's Guide. Intended Audience This information is intended for anyone who installs, upgrades, and configures VMware Identity Manager Connector. The information is written for experienced Windows or Linux system administrators who are familiar with virtual machine technology. VMware, Inc. 5

6 VMware, Inc.

About Upgrading VMware Identity Manager Connector 1 You can upgrade VMware Identity Manager Connector online or offline. By default, the connector uses the VMware Web site for the upgrade procedure, which requires the connector appliance to have Internet connectivity. You must also configure proxy server settings for the connector appliance, if applicable. If your connector instance does not have an Internet connection, you can perform the upgrade offline. For an offline upgrade, you download the upgrade package and set up a local Web server to host the upgrade file. The following upgrade paths are supported: From version 2.3, 2.4, 2015.10.1, or later to the latest version available VMware, Inc. 7

8 VMware, Inc.

Preparing to Upgrade VMware 2 Identity Manager Connector To prepare for the connector upgrade, you must perform a number of prerequisite tasks, such as checking for available upgrades and configuring the proxy server settings for the appliance, if applicable. This chapter includes the following topics: Prerequisites for Upgrade, on page 9 Check for the Availability of a VMware Identity Manager Connector Upgrade Online, on page 10 Configure Proxy Server Settings for the VMware Identity Manager Connector Appliance, on page 10 Prerequisites for Upgrade Before you upgrade the connector, perform these prerequisite tasks. Prerequisites for Online Upgrade Verify that the connector appliance can resolve and reach vapp-updates.vmware.com on port 80 over HTTP. Confirm that a connector upgrade exists. Run the appropriate command to check for upgrades. See Check for the Availability of a VMware Identity Manager Connector Upgrade Online, on page 10. Verify that at least 2 GB of disk space is available on the primary root partition of the appliance. Verify that the connector is properly configured. Take a snapshot of your connector appliance to back it up. For information about how to take snapshots, see the vsphere documentation. If an HTTP proxy server is required for outbound HTTP access, configure the proxy server settings for the connector appliance. See Configure Proxy Server Settings for the VMware Identity Manager Connector Appliance, on page 10. Prerequisites for Offline Upgrade Confirm that a connector upgrade exists. Check the My VMware Downloads site at my.vmware.com for upgrades. Verify that at least 2 GB of disk space is available on the primary root partition of the appliance. Verify that the connector is properly configured. Take a snapshot of your connector appliance to back it up. For information about how to take snapshots, see the vsphere documentation. VMware, Inc. 9

Configure the connector appliance to use a local Web server to host the upgrade file. See Chapter 4, Performing an Offline Upgrade of VMware Identity Manager Connector, on page 13. Check for the Availability of a VMware Identity Manager Connector Upgrade Online If your connector appliance has Internet connectivity, you can check for the availability of upgrades online from the appliance. Procedure 1 Log in to the connector appliance as the root user. 2 Run the following command. /usr/local/horizon/update/updatemgr.hzn updateinstaller 3 Run the following command to check for an online upgrade. /usr/local/horizon/update/updatemgr.hzn check Configure Proxy Server Settings for the VMware Identity Manager Connector Appliance The connector appliance accesses the VMware update servers through the Internet. If your network configuration provides Internet access using an HTTP proxy, you must adjust the proxy settings for the appliance. Enable your proxy to handle only Internet traffic. To ensure that the proxy is set up correctly, set the parameter for internal traffic to no-proxy within the domain. NOTE Proxy servers that require authentication are not supported. Prerequisites Verify that you have the root password for the connector appliance. Verify that you have the proxy server information. Procedure 1 Log in to the connector appliance as the root user. 2 Enter YaST on the command line to run the YaST utility. 3 Select Network Services in the left pane, then select Proxy. 4 Enter the proxy server URLs in the HTTP Proxy URL and HTTPS Proxy URL fields. 5 Select Finish and exit the YaST utility. 6 Restart the Tomcat server on the connector virtual appliance to use the new proxy settings. service horizon-workspace restart The VMware update servers are now available to the connector appliance. 10 VMware, Inc.

Performing an Online Upgrade of 3 VMware Identity Manager Connector You can upgrade your VMware Identity Manager Connector instance online. Prerequisites You have met the prerequisites listed in Chapter 2, Preparing to Upgrade VMware Identity Manager Connector, on page 9. Verify that the connector appliance is powered on and functioning. Procedure 1 Log in to the connector appliance as the root user. 2 Run the following command. /usr/local/horizon/update/updatemgr.hzn updateinstaller 3 Run the following command to check that on online upgrade exists. /usr/local/horizon/update/updatemgr.hzn check 4 Run the following command to update the appliance. /usr/local/horizon/update/updatemgr.hzn update Messages that occur during the upgrade are saved to the update.log file at /opt/vmware/var/log/update.log. 5 Run the updatemgr.hzn check command again to verify that a newer update does not exist. /usr/local/horizon/update/updatemgr.hzn check 6 Check the version of the upgraded appliance. vamicli version --appliance The new version is displayed. 7 Restart the connector appliance. reboot 8 Repeat the preceding steps for each connector appliance in your VMware Identity Manager deployment. The connector upgrade is complete. VMware, Inc. 11

12 VMware, Inc.

Performing an Offline Upgrade of 4 VMware Identity Manager Connector If your VMware Identity Manager Connector appliance cannot connect to the Internet for upgrade, you can perform an offline upgrade. You must set up an upgrade repository on a local Web server and configure the connector appliance to use the local Web server for upgrade. This chapter includes the following topics: Prepare a Local Web Server for Offline Upgrade, on page 13 Configure the Connector and Perform Offline Upgrade, on page 13 Prepare a Local Web Server for Offline Upgrade Before you start the offline connector upgrade, prepare the local Web server by creating a directory structure that includes a subdirectory for the connector appliance. Prerequisites Download the identity-manager-connector-versionnumber-buildnumber-updaterepo.zip file from My VMware. Go to my.vmware.com, navigate to the VMware Identity Manager Download page, and download the file listed under VMware Identity Manager Connector offline upgrade package. Procedure 1 Create a directory on the Web server at http://yourwebserver/vm/ and copy the downloaded zip file to it. 2 Verify that your Web server includes mime types for.sig (text/plain) and.sha256 (text/plain). Without these mime types your Web server fails to check for updates. 3 Unzip the file. The contents of the extracted ZIP file are served by http://yourwebserver/vm/. The extracted contents of the file contain the following subdirectories: /manifest and /package-pool. 4 Run the following updatelocal.hzn command to check that the URL has valid update contents. /usr/local/horizon/update/updatelocal.hzn checkurl http://yourwebserver/vm Configure the Connector and Perform Offline Upgrade Configure the connector appliance to point to the local Web server to perform an offline upgrade. Then upgrade the appliance. Prerequisites Prepare a Local Web Server for Offline Upgrade, on page 13. VMware, Inc. 13

Procedure 1 Log in to the connector appliance as the root user. 2 Run the following command to configure an upgrade repository that uses a local Web server. /usr/local/horizon/update/updatelocal.hzn seturl http://yourwebserver/vm/ NOTE To undo the configuration and restore the ability to perform an online upgrade, you can run the following command. /usr/local/horizon/update/updatelocal.hzn setdefault 3 Perform the upgrade. a Run the following command. /usr/local/horizon/update/updatemgr.hzn updateinstaller b Run the following command to check the version of the available upgrade. /usr/local/horizon/update/updatemgr.hzn check c Run the following command to update the connector. /usr/local/horizon/update/updatemgr.hzn update Messages that occur during the upgrade are saved to the update.log file at /opt/vmware/var/log/update.log. d Run the updatemgr.hzn check command again. /usr/local/horizon/update/updatemgr.hzn check e Check the version of the upgraded appliance. vamicli version --appliance The command should display the new version. f Restart the connector appliance. For example, from the command line run the following command. reboot 4 Repeat the preceding steps for each connector appliance in your VMware Identity Manager deployment. The connector upgrade is complete. 14 VMware, Inc.

Configure Settings after Upgrading 5 Connector After you upgrade to connector 2016.3.1.0, configure these settings. If you use ThinApps, Kerberos authentication, or Active Directory (Integrated Windows Authentication) directories, you must leave the domain and then rejoin it. This is required for all the connector virtual appliances in your deployment. a Click the Identity & Access Management tab. b c d Click Setup. In the Connectors page, for each connector that is being used for ThinApps integration, Kerberos authentication, or an Active Directory (Integrated Windows Authentication) directory, click Leave Domain. Click Join Domain to join the domain again. To join the domain, you need Active Directory credentials with the privileges to join the domain. See "Integrating with Active Directory" in Installing and Configuring VMware Identity Manager for more information about joining a domain. e f If you are using Kerberos authentication, enable the Kerberos authentication adapter again. To access the Auth Adapters page, in the Connectors page click the appropriate link in the Worker column and select the Auth Adapters tab. Verify that the other authentication adapters you are using are enabled. If you are using Active Directory (Integrated Windows Authentication), or Active Directory over LDAP with the This Directory supports DNS Service Location option enabled, save the directory's Domains page. a Click the Identity & Access Management tab. b c d In the Directories page, click the directory. Provide the password for the Bind DN user and click Save. Click Sync Settings on the left of the page and select the Domains tab. VMware, Inc. 15

e Click Save. NOTE In connector 2016.3.1.0 and later, a domain_krb.properties file is automatically created and autopopulated with domain controllers when a directory with DNS Service Location enabled is created. When you save the Domains page after upgrade, if you had a domain_krb.properties file in your original deployment, the file is updated with domains that you may have added subsequently and that were not in the file. If you did not have a domain_krb.properties file in your original deployment, the file is created and auto-populated with domain controllers. See "Integrating with Active Directory" in Installing and Configuring VMware Identity Manager for more information about the domain_krb.properties file. 16 VMware, Inc.

Troubleshooting Upgrade Errors 6 You can troubleshoot upgrade problems by reviewing the error logs. If the connector does not start, you can revert to a previous instance by rolling back to a snapshot. This chapter includes the following topics: Checking the Upgrade Error Logs, on page 17 Rolling Back to Snapshots of Connector, on page 17 Collecting a Log File Bundle, on page 18 Checking the Upgrade Error Logs Resolve errors that occur during upgrade by reviewing the error logs. Upgrade log files are in the /opt/vmware/var/log directory. Problem After the upgrade finishes, the connector does not start and errors appear in the error logs. Cause Errors occurred during upgrade. Solution 1 Log in to the connector appliance. 2 Go to the directory located at /opt/vmware/var/log. 3 Open the update.log file and review the error messages. 4 Resolve the errors and rerun the upgrade command. The upgrade command resumes from the point where it stopped. NOTE Alternatively, you can revert to a snapshot and run the update again. Rolling Back to Snapshots of Connector If the connector does not start properly after an upgrade, you can roll back to a previous instance. Problem After you upgrade your connector instance, it does not start correctly. You reviewed the upgrade error logs and ran the upgrade command again but it did not resolve the issue. VMware, Inc. 17

Cause Errors occurred during the upgrade process. Solution u Revert to one of the snapshots you took as a backup of your original connector instance. For information, see the vsphere documentation. Collecting a Log File Bundle You can collect a bundle of log files to send to VMware support. You obtain the bundle from the connector configuration page. The following log files are collected in the bundle. Table 6 1. Log Files Component Location of Log File Description Apache Tomcat Logs (catalina.log) Configurator Logs (configurator.log) Connector Logs (connector.log) /opt/vmware/horizon/workspace/logs/ca talina.log /opt/vmware/horizon/workspace/logs/co nfigurator.log /opt/vmware/horizon/workspace/logs/co nnector.log Apache Tomcat records messages that are not recorded in other log files. Requests that the Configurator receives from the REST client and the Web interface. A record of each request received from the Web interface. Each log entry also includes the request URL, timestamp, and exceptions. No sync actions are recorded. Procedure 1 Log in to the connector configuration page at https://connectorurl:8443/cfg/logs. 2 Click Prepare log bundle. 3 Download the bundle and send it to VMware support. 18 VMware, Inc.

Index C catalina.log 18 check 10 configurator.log 18 configure 10, 13 connector.log 18 upgrade 7, 11, 13 upgrade prerequisites 9 D domain_krb.properties file 15 E error log 17 G glossary 5 H HTTP proxy 10 I intended audience 5 J join domain 15 L local Web server 13 log bundle 18 log files 18 P post-installation errors 17 prepare 9, 13 proxy server 10 R roll back 17 S snapshot 17 T troubleshooting 17 U update.log 17 VMware, Inc. 19

20 VMware, Inc.