Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.



Similar documents
Control/Communicator Installation Manual

System Introduction S E C T I O N 1

NX-8V2 Control Panel Installation Manual

Reference & Installation Manual

Zone Assignment. PC5010 Zone 1-16 Assignment. System Parti- Zone Label Zone Zone Attributes Serial Number. Zone tion Type (Wireless)

NetworX NX-8 Control/Communicator Installation Manual

NetworX NX-6V2. LED Keypad User Manual

728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION series

NX-8 Installation manual Page 1 Date 13/03/04

SECURITY SYSTEM NOTES

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

INSTALLATION MANUAL PC2525. Version 1.1

TABLE OF CONTENTS FEATURES

SECURITY SYSTEM NOTES

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE Software Version 2.1

ICP-CC488. Installation Guide ICP-CC488 Control Panel

IDS X-Series User Manual D Issued July 2012

Using your LED Plus keypad

GE Concord 4 Quick User Guide

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

Security module CG2 User manual

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

Cerber C Zone and 2-Partition Burglary Control Panel For your home and office

FIRE DETECTION Note: Your installer must enable the fire detection portion of this equipment before it becomes functional.

Program Entry Guide. Control Panels

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

HILLS Series LED Code Pad User Manual

Magellan All-in-one Wireless Security System

Solution-16 Operators Manual ISSUE 1.60

User s Information Guide R1A

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

ABUS WIRELESS ALARM SYSTEM

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

HILLS Series LED Code Pad User Manual

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Installation Guide. Self Contained Wireless Alarm System v1.0

NetworX Series. NX-216E Zone Expander Module Installation and Startup

APR-PRT3 Printer Module: C-Bus Programming Instructions

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

How To Set A Timer On A Gg System

PK5500 v1.1 Installation Instructions

How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power

SPECIAL CONTROL BUTTON FUNCTIONS

First Alert FA140C/142C Installer Notes M. Leuck

LCD and 16-Zone LED Keypads. User s Manual

VISTA-100. Commercial Fire and Burglary 8VHU*XLGH. Partitioned Security System. N Rev B 4/99 FIRE FIRE PULL

MG5000 V2.40 MG5050 V2.40 SP5500 V2.40 SP6000 V2.40 SP7000 V2.40. Reference & Installation

Digiplex Control Panel (DGP-848) - V4.1

NetworX Series. NX-148E LCD Keypad. User Manual

AMAX 2100 / 3000 / en User Guide

Ademco Vista-20P/First Alert FA-168C Basic Commands

32 Zone Wireless Transceiver Security Systems MG5000 V4.0 MG5050 V to 32 Zone Expandable Security Systems SP5500 V4.0 SP6000 V4.0 SP7000 V4.

THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6

AC-115 Compact Networked Single Door Controller. Installation and User Manual


Microprocessor Home Security System

User's Manual. For use with ProSYS 16, ProSYS 40, and ProSYS 128

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

PRT-CTRL-SE. Protege System Controller Reference Manual

SECURITY SYSTEM MANUAL

System Programming Guide

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

PC4020 v3.3 Instruction Manual

Users Guide to Keypad Functions

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

PC1616/PC1832/PC1864 STANDARD INSTALLATION GUIDE

616, 626, 636 & 646 Keypads

SECTION DETECTION AND ALARM

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

Digiplex LCD Keypad DGP-641. User s Manual

VR8. User Guide Intruder Alarm System

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Series. NX-6-EUR Control Panel. Installation manual

XP-600 Programming Instructions

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

XR6/XR10 User s Guide

System Programming Guide (728ULT)

GE Simon XT Quick User Guide

32-Zone Wireless Transceiver Security Systems. 4 to 32-Zone Expandable Security Systems. Programming Guide. MG5000 Version 4.7 MG5050 Version 4.

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Magellan All-in-one Wireless Security System

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

Access Control & Burglar Alarm Integration with KT-300

Using Your. Security System With Icon Keypad S5020, S5021, S5022

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling

10-Zone Spectra LED Keypads

Using Your. Security System. With LED Keypad S5030, S5031, S5032

Destiny Destiny Owners Manual

SECURITY SYSTEM NOTES. Security System Configuration

CONTENTS 4. HOW TO UNSET THE PANEL...7

How To Control A Control Panel With A Pager And A Power Control Unit

VISTA-50P VISTA-50PUL

System Manager s Manual

Transcription:

Application Notes 1.21 Partition Programming (PC1616/1832/1864 V4.2) Panels: POWER SERIES (PC1616/1832/1864 V4.2) Overview: The PC1616 supports 2 true partitions. The PC1832 supports 4 true partitions. The PC1864 supports 8 true partitions. Each partition can have individual user codes, keypads, zones, entry and exit delay times, and account numbers if Contact ID or Pulse format is programmed. Sirens can be partitioned using PGMs or a common siren could be used for all partitions if it is connected to the Main Bell Output. Configuring partitions is a six-step process: - Program user codes to partition 1 8 - Program keypads to partition 1 8 - Program zones to partition 1 8 - Program entry/exit delay times to partition 1 8 - Program separate sirens to partition 1 8 (Optional) - Enter separate account numbers for partition 1 8 (Contact ID and Pulse Format Only) Step 1 Program User Codes to Partition 1 8 1. Enter Access Code Programming To enter Access Code Programming, perform the following: Enter [*][5][Master Code] Enter Access Code Programming LED keypads will turn ON the appropriate LED if the user code is programmed. PK5500 keypads will indicate which codes are programmed by displaying the letter P beside each. PK5501 keypads will flash the number of all access codes programmed. 2. Enter the Access Code Number Enter the Access Code Number: [01] [39] Regular User Codes [41] [95] Regular User Codes [40] Master Code 3. Enter the Arm/Disarm Code Enter the new four-digit code. To delete a code, press the [*] key instead of entering a 4-digit code. Page 42

4. Assign the User Codes to a Partition To assign a user to a partition, enter: [98] Switch to access code partition assignment [01] [95] Access code number The Master Code (User 40) is always assigned to all partitions. Toggle on or off the appropriate option: LED or PK5501 keypad: LED [1] LED [2] LED [3] LED [4] LED [5] LED [6] LED [7] LED [8] Partition 1 enable/disable Partition 2 enable/disable Partition 3 enable/disable Partition 4 enable/disable Partition 5 enable/disable Partition 6 enable/disable Partition 7 enable/disable Partition 8 enable/disable PK5500 keypad: Partition 1 Partition 2 Partition 3 Partition 4 Partition 5 Partition 6 Partition 7 Partition 8 Partition 1 enable/disable Partition 2 enable/disable Partition 3 enable/disable Partition 4 enable/disable Partition 5 enable/disable Partition 6 enable/disable Partition 7 enable/disable Partition 8 enable/disable 5. Assign User Codes Attributes (Optional) Each User Code has attributes assigned to it. To assign attributes to a User Code, enter: [99] Switch to access code attributes [01] [95] Access Code number This is not available for the Master Code (User 40). Toggle on or off the appropriate option: LED or PK5501 keypad: LED [1] LED [2] LED [3] LED [4] LED [7] LED [8] User can enter User Code Programming section with this code Duress Reporting Code is sent whenever this code is entered Zone Bypass enable/disable ESCORT5580 enable/disable Bell Squawk enable/disable Temporary Code Page 43

PK5500(Z) keypad: Master Duress Zone Bypass Phone Access Bell Squawk Temporary User can enter User Code Programming section with this code Duress Reporting Code is sent whenever this code is entered Zone Bypass enable/disable ESCORT5580 Access enable/disable Bell Squawk enable/disable (1 Squawk Arm, 2 Squawk Disarm) Temporary Code (One Time Use) When finished program access code attributes, press [#] to exit. Attributes [5] [6] are for future use. After the attributes are programmed for the user code and [#] is pressed, the keypad will go back to regular access code programming. Step 2 Program Keypads to Partition 1 8 1. Partition 2 8 Enable Partitions 2 through 8 must be enabled before keypads assigned to a partition 2 8 will operate. To enable partition 2 to 8, perform the following: Enter [*][8][Installer s Code] Enter Installer s Programming Enter [201] Enter Partition 1 to 8 Enable Press [2] to turn ON option [2] Enable Partition 2 Press [3] to turn ON option [3] Enable Partition 3 Press [4] to turn ON option [4] Enable Partition 4 Press [5] to turn ON option [5] Enable Partition 5 Press [6] to turn ON option [6] Enable Partition 6 Press [7] to turn ON option [7] Enable Partition 7 Press [8] to turn ON option [8] Enable Partition 8 2. Keypad Assignment Program the Partition Assignment and Slot of each keypad. To assign the keypad, perform the following: Enter [*][8][Installer s Code] Enter [000] Enter [0] Enter Installer s Programming Enter Keypad Assignment Section Enter Partition and Slot Section Enter a two-digit number. The first number represents the partition assigned to the keypad: Enter data [0] for Global Mode Enter data [1] for Partition 1 Enter data [2] for Partition 2 Enter data [3] for Partition 3 Enter data [4] for Partition 4 Enter data [5] for Partition 5 Enter data [6] for Partition 6 Enter data [7] for Partition 7 Enter data [8] for Partition 8 The second digit represents the supervisory slot. Each keypad MUST have a different slot number: Enter data [1] to [8] for supervisory slot #1 to #8 The same procedure must be performed on each keypad. Keypads must each be assigned to a specific slot for the keypads to be properly supervised. Page 44

If a PK5500Z keypad is connected to the panel, it must be assigned to slot #8 for downloading purposes. In addition, only one PK5500(Z) can be assigned to Slot 8. If LCD programming changes are made using the DLS software, the keypad assigned to slot #8 will transmit the changes to all the other PK5500Z keypads on the system after the download is complete. 3. Module Supervisory Reset Since all modules are automatically detected and supervised by the panel within the first minute after being connected, a Module Supervisory trouble condition may occur after keypad slot assignments are changed. After all keypads have been assigned to a Partition and Slot, perform the following to perform a Module Supervisory Reset: Enter [*][8][Installer s Code] Enter [902] Enter Installer s Programming Enter Module Supervision Reset Wait 1 minute. To verify what modules are present, perform the following: Enter [903] Enter Module Supervision Display The keypad will display the modules present. LED keypads will be limited to the number of modules it can display. To determine which LED represents which module, refer to the Installation Manual, Section [903]. Step 3 Program zones to partition 1 8 1. Programming Zone Definitions Zones must be defined before they will operate. On the POWER SERIES, 39 different zone definitions are available. Enter the correct section and program the 2-digit number corresponding to the required zone definition. Section [001] Zones 1 to 16 Section [002] Zones 17 to 32 Section [003] Zones 33 to 48 Section [004] Zones 49 to 64 2. Programming Zone Attributes (Optional) Zone attributes are used to customize the operation of each zone. There are 64 sections available, Section [101] for zone 1 to Section [164] for zone 64. Each Section has 9 toggle options. Turn the appropriate option ON or OFF depending on the required operation. Option [1] Zone audible/silent Option [2] Steady bell output/pulsing bell output Option [3] Door chime enable/disable Option [4] Manual bypass enable/disable Option [5] Force arm enable/disable Option [6] Swinger shutdown enable/disable Option [7] Transmission delay enable/disable Option [8] Wireless zone enable/disable Option [9] Cross Zone enable/disable Option [14] NC Zone Wiring loop Option [15] EOL Zone Wiring loop Option [16] DEOL Zone Wiring loop Options 14, 15, 16 apply to first 8 zones only. If more than one of these options are enabled then lowest numbered option is enabled. E.g., If Option 14 and option 15 are enabled then the zones are configured as normally closed loops. Page 45

The zone attributes for the zone will reset to the default settings if the zone definition is changed. A chart of the default settings for each zone definition is available in the Programming Worksheets. 3. Partition Zone Assignment Zones will not function until they are enabled. Enable all zones being used by turning ON the appropriate option in Section [202] to [265]. Section [202] [209] Section [210] [217] Section [218] [225] Section [226] [233] Section [234] [241] Section [242] [249] Section [250] [257] Section [258] [265] Partition 1 zones 1 to 64 enable/disable Partition 2 zones 1 to 64 enable/disable Partition 3 zones 1 to 64 enable/disable Partition 4 zones 1 to 64 enable/disable Partition 5 zones 1 to 64 enable/disable Partition 6 zones 1 to 64 enable/disable Partition 7 zones 1 to 64 enable/disable Partition 8 zones 1 to 64 enable/disable If zones are assigned to additional partitions, ensure the partitions are enabled in Section [201]. Step 4 Program entry/exit delay times to partition 1 8 1. Enter System Time Section On the POWER SERIES, each partition has its own entry and exit delay times. Enter the System Times section [005] followed by the 2-digit partition number corresponding to the required system times. [005] followed by [01] for Partition 1 [02] for Partition 2 [03] for Partition 3 [04] for Partition 4 [05] for Partition 5 [06] for Partition 6 [07] for Partition 7 [08] for Partition 8 2. Enter Entry/Exit Delay Times Enter 001 255 for Entry Delay#1 Enter 001 255 for Entry Delay#2, (000 if not used) Enter 001 255 for Exit Delay Press [#] to exit the section Step 5 Program separate sirens to partition 1 8 (Optional) 1. Program the PGM 1 14 definition On the POWER SERIES the BELL+/- terminals activate when any partition enters alarm however each partition can have its own siren output. To have separate sirens, wire the (+) of the siren to the AUX+ terminal and the negative of the siren to the PGM terminal. A DSC-RM1 Relay may be required if the siren current draw exceed the PGM current limit. PGM 1, 3-10 can provide 50mA of current. PGM 2 can provide 300mA of current. PGM 11-14 can provide 1amp of current. The PGMs will not function until they are programmed as [01 Burg and Fire]. Enter all PGMs being used for siren outputs as [01] in sections [009] [011]. Section [009] PGM 1 PGM 2 Section [010] PGM 3 PGM 10 (PGMs on a PC5208 Expander) Section [011] PGM 11 PGM 14 (PGMs on a PC5204 Expander) Page 46

2. Partition the PGM PGMs will activate on Partition 1 at default. To have the PGM activate on another partition you will need to disable Partition 1 (option 1) and enable another partition (option 2-8). Enter Section [551] [564] and toggle options 1-8 to partition the PGM to that partition. PGM1 Partition Assignment is Section [551] PGM2 Partition Assignment is Section [552] PGM3 Partition Assignment is Section [553] PGM4 Partition Assignment is Section [554] PGM5 Partition Assignment is Section [555] PGM6 Partition Assignment is Section [556] PGM7 Partition Assignment is Section [557] PGM8 Partition Assignment is Section [558] PGM9 Partition Assignment is Section [559] PGM10 Partition Assignment is Section [560] PGM11 Partition Assignment is Section [561] PGM12 Partition Assignment is Section [562] PGM13 Partition Assignment is Section [563] PGM14 Partition Assignment is Section [564] Step 6 Enter separate account # for partition 1 8 (Contact ID and Pulse format Only) 1. Program the Telephone Number Program the central station phone number in Section [301]. 2. Program the System Account Number Program the system account number in Section [310]. For Contact ID and Pulse, program a HEX digit [A] for any digit 0 in the account number. 3. Program the Partition Account Numbers (Contact ID and Pulse Only) Program the partition 1 to 8 account number in Section [311] [318]. For Contact ID and Pulse, program a HEX digit [A] for any digit 0 in the account number. 4. Program the Communication Format Program [01] [04] in Section [350] for telephone number 1. Enter [01] for Pulse format 1400Hz handshake format Enter [02] for Pulse format 2300Hz handshake format Enter [03] for DTMF Contact ID format Enter [04] for SIA-FSK format 5. Step 5 (Optional) Program the Communicator Call Direction Options Communicator Call Direction options are used to determine which events will be reported to which phone number. By default option [1] is ON in all Sections and all events will transmit using phone number 1. To disable the reporting of a group of codes (i.e. openings and closings) turn option [1] OFF in the correct Section. Section [351] [358] Alarm/Restoral for Partitions 1-8 Section [359] [366] Tamper Alarm/Restoral for Partitions 1-8 Section [367] [374] Opening/Closing for Partitions 1-8 Section [375] Maintenance Alarms/Restorals Section [376] Test Transmission Page 47

6. Program the Reporting Codes (Optional) The panel will automatically transmit the correct Contact ID reporting code for all events if the reporting code for the event is anything other than data [00]. By default, all reporting codes are programmed as data [FF], which means the panel will report all possible events. It is important to disable the reporting of unwanted events by programming data [00] for those events. Section [320] [349] Section [601] [608] Reporting Codes Reporting Codes Technical Tips: 1. Ensure all the partitions have been enabled in programming section [201]. Quick Test Procedure: First, violate/secure zone on specific partitions and verify on the keypad that the appropriate zone only show open on the appropriate partition keypads. Second, program user codes on specific partition and ensure they only arm the appropriate partition on the appropriate partition keypads. Page 48