1- Monitoring of Industrial Pollution



Similar documents
Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Ambient Air Monitoring at Deployment Locations in the Middle East

AMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better.

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015

How To Measure The Flow Rate Of A Cement Plant

Application Requirement

Mechanical Systems Competency 1.20

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Draeger-Tubes and accuro Pump

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009

Automotive Air Quality Sensors: industrial innovations to protect people s health

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Continuous Emissions Monitoring - Program 77

Oil and Gas Air Quality Regulations and Permitting

(a) Method 1 Sample and Velocity Traverses for Stationary Sources.

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

The photoionization detector (PID) utilizes ultraviolet

Manual stack emission monitoring Performance standard for organisations. Environment Agency November 2011 Version 7.2

Electronic Reporting to BTS

Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants

Laboratory analysis for wastewater treatment, industrial monitoring, and environmental protection

Advanced Solutions for Gas Monitoring

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

THE DETECTION OF GREENHOUSE GASES

Summer Holidays Questions

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

ETV Joint Verification Statement

COURSE TITLE COURSE DESCRIPTION

Standard Operating Procedure for Training for Staff Working on the PM 2.5 Chemical Speciation Program

Cartridge Change Schedule

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

QUEENSLAND FIRE AND RESCUE SERVICE SCIENTIFIC BRANCH

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Neutralizing an Acid and a Base

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

IB Chemistry. DP Chemistry Review

Source Apportionment Strategies for Atmospheric Particulate Matter in Mega-Cities

Department of Environmental Engineering

Lab facilities for School of Architecture and Built Environment

Study Plan. MASTER IN (Energy Management) (Thesis Track)

Hazardous Waste Procedures. Faculty of Science University of Ottawa

Experiment #5: Qualitative Absorption Spectroscopy

Environment-Laboratory Ambient Conditions

The Empirical Formula of a Compound

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Solubility Curve of Sugar in Water

Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test

Approved Methods. for the Sampling and Analysis of Air Pollutants in New South Wales

Pennsylvania Marcellus Shale Short- Term Ambient Air Sampling Project

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Solution. Practice Exercise. Concept Exercise

Multi-pollutant control solutions for coal based power plants

PROPOSAL AIR POLLUTION: A PROJECT MONITORING CURRENT AIR POLLUTION LEVELS AND PROVIDING EDUCATION IN AND AROUND SCHOOLS IN CAMDEN

Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH

Clean Up Your Fleet. Introducing a practical approach to cleaner, more efficient fleet operation

Quality Assurance for the Analysis of Steel by Gas Component Analysis

Pesticide Analysis by Mass Spectrometry

A Guide for Local Authorities Purchasing Air Quality Monitoring Equipment

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

World s Best Oil in Water Analyzers

GUIDELINES FOR ENVIRONMENTAL MANAGEMENT A GUIDE TO THE SAMPLING AND ANALYSIS OF AIR EMISSIONS AND AIR QUALITY

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

CHEMICAL SENSORS 1. DEFINITION

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Building Diagnostic Tests as Assessment Tools 診 斷 樓 宇 狀 況 的 測 試 : 樓 宇 檢 驗 的 評 估 工 具

TR SUPPLEMENTARY REQUIREMENTS FOR THE ACCREDITATION OF CONTINUOUS AMBIENT AIR QUALITY MONITORING STATIONS

Quality Assurance/Quality Control in Acid Deposition Monitoring

13C NMR Spectroscopy

National Environment Protection (Ambient Air Quality) Measure

Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers

sierra monitor corporation Fire and Gas Detection Systems

Environmental Automated Measuring Systems for Flue Gas

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

The Ambient Air Monitoring System

ABSTRACT INTRODUCTION

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

BP Texas City Refinery

Ambient Air Monitoring Work plan For National Core (NCore) Monitoring Station

Unit title: Chemical Laboratory Techniques

Continuous flow direct water heating for potable hot water

Measurement Systems for Diesel Exhaust Gas and Future Trends. Oxidation catalyst DPF Flow mete. Soft ionization mass spectrometer

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Table of Contents 1. INTRODUCTION... 1

Physical flow accounts: principles and general concepts

INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources

ngenieros Ingenieros Asociados De Control S.L.

Advanced Treatment of Hazardous Wastes(1) Advanced Treatment of Hazardous Wastes(2) Advanced Environmental Chemistry. Design of Solid Waste Landfill

Transcription:

$541 &I*\ ib3 - '+dl +I\ + Office of Research - Central Laboratories Unit m -4 Details on the Courses Offered 1. Lecturers: Professors, experts and technicians in the CLU 2. Language: English 3. Applied field: include the use of instruments, result treatment....... 4. Certificate: will be awarded by the university after passing an exam. Attendee who chose not to take the exam will be given certificate for attending the courses. However, they have to attend at least 80% of the courses (4 out of five days). 5. Place: Central Laboratories UnitfOffice of researcwqatar University. (Located in Art and Science building, corridor # 3) 1- Monitoring of Industrial Pollution Duration: 5 days. (December 21 (Sun) - 25 (Thu) 12008); (from 9:00 am - 2:00 pm) Activities: Lectures and Exercises Cost: RQ 2000 per participant Detailed Subjects (1 Air quality and pollution Air composition. Air pollution. Primary air pollutants Secondary air pollutants Nature and characteristics of air pollutants Sources of air pollutants Industrial activities and nature of their main emissions. Criteria for selecting pollutants and emission points to be monitor Formulation of a pollution monitoring plan. (2) Air and gas samplers Rotary Vane, dual, venture pumps and gas flow meters. Dioxin sampler Low volume air sampler High volume air sampler Tedlar gas bag sampler Green-Berg Smith impinger gas sampler Passive -diffusive air sampler Badge gas sampler Isokinetic stack sampler Vacuum glass tube gas sampler 9 LJ+f12713 :+* (+974) 4851 153 :@ - (+974) 4852510 :& Tel:(+974) 4852510 - Fax: (+974) 4851 153 - P.0 Box: 2713 Doha-Qatar e-mail: CLU@qu.edu.qa, wibsite: http://www.qu.edu.qa

$$psl &\$dl ih3 - &I\ +A Office of Research - Central Laboratories Unit m -b (3) Gas emission monitoring equipment Portable electrochemical gas monitors Flue gas monitors Nondispersive infrared gas monitors Flame ionization gas detectors (FID) Differential absorption gas monitors, Lidar (DIAL) Tunable diode laser absorption spectrometer gas monitor (TDLAS) Long-path absorption gas monitor (DOAS) High-resolution Fourier transform gas monitors Chemiluminescence gas monitors Surface acoustic wave gas sensors. Catalytic bead (Pellistors) gas sensors. Metal oxide semiconductor (MOS) gas sensors. Colorimetric gas detection tubes Smoke light reflectance monitors Workplace single and multi gas monitors Dust monitors Real-time particulate monitors Laser dust monitors Volatile organic monitors (4) Gas emission monitoring frequency Instant emission monitoring Occasional emission monitoring Regular emission monitoring Frequent emission monitoring Intensive emission monitoring Continuous emission monitoring On-line emission monitoring (5) Weather and climate metrology The weather and climate, source, factors, variability and change The impact of climate on the quality and homogeneity of pollution monitoring data. Weather station sensors( Barometers, rainfall-meters, dust fall-meters, solar - meters, hygrometers, tachometers, thermometers, light- meters, hot wire anemometer, rotating Vane anemometer, ultrasonic anemometer Metrological parameters measured for air pollution assessment. - ---- ---------- 9 LJA 2713 :+I.* (+974) 4851153 :&A - (+974) 4852510 Tel:(+974) 4852510 - Fax: 1(+974) 4851153 - P.0 Box: 2713 Doha-Qatar e-mail: CLU@qu.edu.qa, wibsite: http:/iwww.qu.edu.qa

Office of Research - Central Laboratories Unit m -b (6) Standard methods of analysis of gaseous emissions Determination of indoor and point source emissions: Sulfur dioxide and sulfur trioxide. Ozone. Nitrogen oxides Total particulates PMlO, PM 5, PM 2.5 Hydrogen chloride. Hydrofluoric acid. Metals. Carbon monoxide. Hydrogen sulfide Total hydrocarbons. Volatile organic hydrocarbons. Ammonia. Chlorine. Fluorine. Hydrocyanic acid. (7) Data recording, handling, treatment and reporting Pollution loads. Quality control/quality assurance for emission monitoring. Control charts. Interpretation of control charts. Data treatment and interpretation. Records, reporting and data handling. (8) National and international air quality standards Standards of ambient air quality according to the local law Standards of point source emissions according the local law Standards of emissions from workplace according to the local law Global, regional and national air quality standards. Air pollution control and cleaning systems. 9 L3111 2713 :u.@ (+97J) 4851 153 :& - (+974) 4852510 :a Tel:(+974) 4852510 - Fax: (+974) 4851153 - P.0 Box: 2713 Doha-Qatar e-mail: CLU@qu.edu.qa, wibsite: http://ww~v.qu.edu.qa

$$A\ &\*I Zhj - &d\ Office of Research - Central Laboratories Unit dw 2- Quality and IS0 Standards Duration: 5 days (April 12 (Sun) - 16 (Thu) 12009); (from 9:00 am - 2:00 pm) Activities: Lectures and Exercises Cost: RQ 2000 per participant Detailed Subjects (1) Concept of Quality Quality ControVQuality Assurance Quality Management Total Quality Management IS0 Standards General description of IS0 9000, 14000. 17000 and 18000 standards and detailed description of IS0 17025 (2) IS0 9000: Quality Management Systems (3) IS0 14000: Environmental Management Systems (4) OHSAS 18001: Occupational Health and Safety (5) IS0 17799: Information Security Management (6) IS0 17025: Competence of Testing and Calibration Laboratories What is IS0 17025? Management Requirements - Organization - Quality system - Document control - Review of requests, tenders and contracts - Subcontracting of tests and calibrations 9 L& 2713 :+# (+9?4) 4851153 :A - (+974) 4852510 Tel:(+974) 4852510 - Fax: (+974) 4351 153 - P.0 Box: 27 13 Doha-Qatar +mail: CLU@qu.tdu.qa, wibsitc: http:lhcww.qu.edu.qa

$jspjl &I* ;As, - + +4 Office of Research - Central Labsratories Unit d-w OATAR UNIVERSITY - Purchasing services and supplies - Service to client - Complaints - Control of nonconforming testing andlor calibration work - Corrective action - Preventive action - Control of records - Internal audits - Management reviews Technical Requirements - Personnel - Accommodation and environmental conditions - Test and calibration methods and method validation - Equipment - Measurement traceability - Sampling - Handling of test and calibration items - Assuring the quality of test and calibration results - Reporting the results Jhi k#i 2713 :+~p (t974) 4851 153 :&- (+974) 3852510 :A Tcl:(+974) 4852510 - Fax: (+974) 1851 153 - P.0 Box: 2713 Doha-Qatar e-mail: CLU@qu.edu.qrr, witmite: http://www.qu.edu.qa

&l*l 5h9 - &\ -1 +& Office of Research - central-~aboratories Unit m -4 3- Modern Methods of Industrial Analysis Duration: 5 days (April 19 (Sun) - 23 (Thu) 12009); (from 9:00 am - 2:00 pm) Activities: Lectures and Laboratory Practical Work Cost: RQ 2000 per participant Detailed Subjects (1) Quality and safety requirements of laboratories Laboratory quality management requirements: Laboratory organization and responsibilities, quality system, documents, records and reports control, control of non-conforming testing and calibration, corrective actions, preventive actions., internal audit, management review. Laboratory quality technical requirements: Standard operational procedures (SOP'S), method validation, calibration and maintenance of equipments, quality control/quality assurance plans, participation in proficiency testing. Laboratory Safety: Chemical hygiene responsibilities, chemical inventory, storage and handling, material safety data sheets (MSDS), chemical spills and spill clean up, hazardous waste disposal, protective equipments, fire types, safety and distinguishing, safety of electricity, water and gas lines and connections, handling and storage of compressed gas cylinders, emergency procedures, handling of laboratory accidents (2) Quality control/quality assurance Equipments: Calibration: methods and schedules. Control charts: Types (X-, R-, r- and D-charts), types of internal quality control samples, daily interpretation of control charts, long term use of control chart data. Type of analysis: Standard addition (spiking technique), analysis of blind samples, analysis of split samples, repeated (or duplicate) analysis, blank assessment, use of certified reference materials. (3) Assessment of data quality Nature and sources of errors: random errors, systematic errors, gross errors, Rounding errors Statistical evaluation: Measurement of data central tendency, measurement of data dispersion, standard deviation, within-batch standard deviation, between-batch, standard deviation, pooled standard deviation, reproducibility and repeatability, comparison of two standard deviations, confidence interval of a mean, comparison Lfi 2713 :+* (+974) 4851 153 :A - (+974) 4852510 :a Tel:(+974) 4852510 - Fax: (+974) 4851 153 - P.0 Box: 2713 Doha-Qatar e-mail: CLU@,qu.edu.qa, wibsite: http://www.qu.edo.qa

&\-I '.h, - '.+I\ -1 +GL Office of Research - Central Laboratories Unit of two mean values, outliers, lower limits of detection and quantification, F-test and t-test,graphing ( spatial-trend and time-history graphs), Results uncertainty. (4) Electrochemical methods of industrial analysis Introduction: How to construct your own low cost ion selective sensor. Potentiometry with ion selective electrodes: Types of membrane sensors, homogeneous solid state, heterogeneous solid state, liquid and gas sensors, potentiometric titration, Gran's plot, application for industrial analysis of cement, metals, detergents, fertilizers, food products, organic compounds.. (5) Molecular spectrochemical methods of industrial analysis Spectrophotometry: Theory, instrumentation, measurement techniques and applications for industrial analysis. Infrared spectrometry: Theory, instrumentation, measurement techniques and applications for industrial analysis. Fluorescence and phosphorescence: Theory, instrumentation, measurement technique and applications for industrial analysis. (6) Atomic spectrochemical methods of industrial analysis Atomic absorption spectrometry: Theory, instrumentation, techniques, calibration and application for industrial analysis. Inductively coupled and direct current plasma :Theory, instrumentation. techniques and applications to industrial analysis X-ray fluorescence: Theory, instrumentation and application to industrial analysis. (7) Chromatographic methods of industrial analysis Ion chromatography High pressure liquid chromatography GasAiquid chromatography 9 && 2713 :+p (t974) 4851153 :&A - (+974) 4852510 :a Tel:(+974) 4852510 - Fax: (+974) 4851153 - P.0 Box: 2723 Doha-Qatar e-mail: CLU@qu.tdu.qa, wibsite: http://www.qu.edu.qa