SOCT Copernicus HR Specification

Similar documents
NEW. CIRRUS HD-OCT 5000/500 Advancing Smart OCT. Imaging Applications: Anterior Segment Glaucoma Retina. International Version

Measure of Confidence. Glaucoma Module Premium Edition

The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan

Optic Nerve Imaging. Management of Glaucoma

CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.

When a Macular Hole Is Not A Macular Hole. Contents. OCT Anatomy. Vitreomacular Traction 3/1/2012

Three pearls in one shell. Heidelberg Retina Tomograph

Cataract Testing. What a Patient undergoes prior to surgery

MASTER OCT LECTURE OUTLINE Ophthalmic Photographers Society November 16, 2013 New Orleans, LA

PATIENT INFORMATION BOOKLET

iocutouchtm for ipad Contents of Videos and Still Images Anatomy 906. Normal Eye and Orbit - no labels 907. Normal Eye and Orbit - with labels

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture.

Understanding Visual Fields, Part III; Which Field Should Be Performed?

Graduate Diploma in Optometry. Related modules Pre-requisites Satisfying requirements of second year BSc (Hons) Optometry examination board

Introduction Houston Retina Associates

Spectral domain OCT used to view and quantify choroidal vascular congestion in new subretinal fluid following scleral buckling.

Which eye conditions can avastin injections be used for?

Ophthalmic Consultants of Long Island

~Contributing to Eye Health~

Retinal Imaging Biomarkers for Early Diagnosis of Alzheimer s Disease

Age- Related Macular Degeneration

Boomers and Disease Detection with OCT: Catalyst for Optometric Practice Growth

There may be no symptoms at first. Eye problems can. You can help prevent eye problems. Just because you have

Trends in Ophthalmology a Market Perspective. Matthias Karl, Michael Kempe

Fundus Photograph Reading Center

The Normative Database for the RTVue. Software version 4.0. Michael J. Sinai, PhD

Get Your Eyes Examined

Avastin (Bevacizumab) Intravitreal Injection

82 Gilbert Street, Adelaide, SA, Gilbert Street, Adelaide, SA, 5000 W M W M

Age-Related Eye Diseases and Conditions. See Well for a Lifetime

EFFECT OF MYOPIC LASIK ON RETINAL NERVE FIBER LAYER THICKNESS- IS IT SAFE OR UNSAFE?

Do You STILL Need Technology? DO YOU STILL TECHNOLOGY? The Challenges in The Challenges in FEC s Production Reports 2012

Michalina Góra, Jan Marczak, Antoni Rycyk, Piotr Targowski APPLICATION OF OPTICAL COHERENCE TOMOGRAPHY TO MONITORING OF LASER ABLATION OF VARNISH

Optical Coherence Tomography OCT. 3D Imaging in Medical Technology and Quality Control

This newest generation laser offers specific technological features and treatment options designed to substantially improve the retina laser therapy:

IMAGE ASSISTANT: OPHTHALMOLOGY

Visual Acuity, Impairments and Vision Insurance Plan Provisions. Stuart West Specialty Sales Manager Virginia CE Forum 2009 Course #

Retinal assessment using optical coherence tomography $

Taking Your Fundus Exam to the Next Level

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Eye Diseases , The Patient Education Institute, Inc. otf30101 Last reviewed: 05/21/2014 1

ICG IMAGING FOR EXUDATIVE ARMD

How To Understand The Current Of An Optic Nerve Fiber Layer

Vitreo-Retinal and Macular Degeneration Frequently Asked Questions

Principles of Diagnosis MEDICAL DECISION-MAKING IN OPTOMETRIC PRACTICE. Medical Decision-Making. Medical Decision-Making.

The Eye: Anatomy, Histology & Histopathology. Gillian Shaw, DVM, MS September 9, 2011 gilliancshaw@gmail.com

Financial Disclosure. LASIK Flap Parameters IntraLase Microkeratome 6/9/2008. Femtosecond LASIK Flaps: What Could We Customize Yesterday?

Applications in Dermatology, Dentistry and LASIK Eye Surgery using LASERs

The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty

Preparing for laser treatment for diabetic retinopathy and maculopathy

Tucson Eye Care, PC. Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens

ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography

Top Medicare Audit problems. Retinal Imaging Technology. Optometric Medical Coding. Unilateral codes. Modifiers

Donna McCune, CCS-P, COE Vice President Corcoran Consulting Group

Optic Disc Drusen. Normal Enlarged view of Optic Disc. Lumpy Appearance of Optic Disc. Optic Disc Drusen With Drusen

Descemet s Stripping Automated Endothelial Keratoplasty (DSAEK)

Geographic Atrophy: The Advanced Form of Dry AMD

OCULUS Pentacam Pentacam HR

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Comparison to other anterior segment imaging devices

Help maintain homeostasis by capturing stimuli from the external environment and relaying them to the brain for processing.

Overview of Optical Recording Technology- Current Status and Near Term Projections

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Range of number of pharmaceuticals/medications per patient: 2-33 Average number of pharmaceuticals/medications listed per patient: 11

femtosecond laser platform Exceptional versatility without compromise

Marketing Samples Medical Optometry

THE EYES IN MARFAN SYNDROME

BSM Connection elearning Course

Ophthalmic Equipment Guide

DISTANCE LEARNING COURSE. Anatomy of the Patient Exam , BSM Consulting All rights reserved.

Physical and Mental Conditions Guidelines VISION CONDITIONS AND ACTIONS Page 5.4

Residency Program in Ocular Disease and. Refractive and Ocular Surgery

Femto-LASIK. Pulsewidth: Ultrashort-pulse micro- machining can make sub- wavelength holes. micromachining

Application Report: Running µshape TM on a VF-20 Interferometer

Alexandria s Guide to LASIK

Vitreomacular Traction: What s the Role of the Vitreoretinal Interface in this Disease?

SHEEP EYE DISSECTION PROCEDURES

CLINICAL SCIENCES. Enhanced Depth Imaging Optical Coherence Tomography of Small Choroidal Melanoma

EPISCLERAL EYE PLAQUES FOR TREATMENT OF INTRA-OCULAR MALIGNANCIES AND BENIGN DISEASES

Preparing for ICD-10 Advance Preparation for Implementation Charles Brownlow, OD

List of Abbreviations (Condition) Clinical Pearls in Vitreoretinal Surgery. List of Abbreviations (Procedure) PPV indications

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

MODERN CLINICAL OPTOMETRY BILLING & CODING THE MEDICAL EYE EXAMINATION. Definitions of Eye Examinations. Federal Government Definition

ReLEx smile Minimally invasive vision correction Information for patients

LASIK Wavefront Guided idesign LASIK with IntraLase

Andrew Ilyas and Nikhil Patil - Optical Illusions - Does Colour affect the illusion?

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

OCT-C. Optical Coherence Tomographer-Certified Program Guide BOARD OF CERTIFICATION. Version 1

Refractive Surgery. Evolution of Refractive Error Correction

Excimer Laser Refractive Surgery

The Clinic You see - at Sjonlag Eye Center, we care about your eyes

Scanning laser polarimetry and retinal thickness analysis before and after laser in situ k e r a t o m i l e u s i s

Keratoconus Detection Using Corneal Topography

An introduction to Optos

Transcription:

Specification Light Source: SLED Central Wavelength: 850 nm Axial Resolution: 3 µm Transversal Resolution: 12-18 µm Scanning Speed: 52000 A-Scan per second A-Scan Resolution: 1024 points B-Scan Resolution: 20000 A-Scans Max. B-Scan width: 10 mm Scanning Density: 2000 A-Scans per mm Scan Patterns: 3D, Cross, B-Scan, Asterisk, Circle, Animation, Doppler Analysis: Dimensions: Retina: Retina thickness, Retina volume, RNFL thickness, RNFL volume, RPE deformation, IS/OS thickness Glaucoma: RNFL, ONH morphology, DDLS Anterior: Pachymetry, LASIK flap, Angle Assesment, AIOP 640 x 680 x 520 H x W x D Power supply: 100-250V 50/60Hz www.optopol.com Local Distributor: Member of Canon Group OPTOPOL Technology S.A. ul. Żabia 42, 42-400 Zawiercie, POLAND Tel/Fax: +48 32 6709173, info@optopol.com.pl ver. SOCT Copernicus HR 03-2011

Member of Canon Group

Ultrahigh resolution gives doctor comfort of confidence in diagnosis.at the same time sharp details give no chance to make a mistake. Ultrahigh scanning speed shortens data collecting time and essentially improves comfort of examination both for patient and operator. World s highest resolution, highest scanning speed combined with advanced analysis algorithm make SOCT Copernicus HR state of the art in SOCT technology. Features» Highest optical resolution more focused details more reliable diagnosis» Easy operation» Shorter time of examination less fatigue to patient easier operation» Comprehensive analysis tools for fovea, disc, anterior chamber The Need for Speed SOCT Copernicus HR scan speed minimizes the motion artifacts. HR Software Features» Retina and RNFL volume maps» Optic nerve head analysis» Progression module» Symmetry module» User customized printouts» Multi lingual interface» 3D visualization traction visualization, enhanced, preview, peeling, slicing, C-SCANS» Advanced image recognition mechanisms» Short calculation time» Positioning tomograms on the picture of the surface of retina» Retina tracking system

Glaucoma Module A Powerful Predictor of Change» Validated by ophthalmologists to predict structural change» Optic disc analysis outperforms expert interpretation» Large normative database» Progression analysis» Symmetry analysis» Network ready» DICOM connectivity» Pachymetry» Angle assessment The SOCT Copernicus HR Glaucoma Module is an essential tool for the detection and management of Glaucoma. Essentially, the tool allows detection on pupillary defect and tracks progression with time. The essential components of the Glaucoma Module are: Healthy Disc DDLS scale shows caution rating. Glaucomatous Disc RNFL trend follows normative curve. Disc Morphology Quantification Disk Damage Likelihood Scale (DDLS) The DDLS is a new way to analyze the optic nerve. Instead of a cup/disc (c/d) ratio, a rim/disc (r/d) ratio and the nerve size is measured. This methodology is superior than any other reporting measure for two reasons: a. DDLS eliminates the effects of disc size, which is so variable in people. b. DDLS measure provides more weightage to the rim, which is the actual part that is damaged in Glaucoma. DDLS scale shows high damage. RNFL thickness is below normal. Symmetry Analysis Correctly identifies patients with glaucomatous field loss and shows abnormalities in many patients considered at high risk for glaucoma who still have normal fields. Asymmetry analysis is also able to identify objectively the extent of glaucomatous damage and detects changes before subjective field lossoccurs. Progression Analysis Glaucoma module allows complete and detailed progression analysis of the RNFL thickness, comparison to the normal population, DDLS scale and difference from baseline plots to highlight progression and/or comparison of disc scans at various stages of time. SOCT Copernicus HR Symetry Analysis Progression Analysis

Anterior Segment Module 3D and Fovea The anterior segment module allows cornea and anterior imaging with a resolution of 5 micron. SOCT Copernicus HR SOCT Copernicus HR software allows: 1. Pachymetry map. 2. Epithelium thickness measurement 3. AOD, TISA 4. LASIK Flap 5. Anterior lens measurement 6. IOP correction The new advanced 3D module allows visualiation of the 3D reconstruction. Peeling facilitates localization and review of the pathology for detailed analyzis. Thickness of the retina, RNFL and RPE can be seen for any spot on the 3D picture - enabling quick and easy study of the structures. Vitreomacular tractions can be vislualized, highlighted and removed for easy patient understanding.

New Software ver 4.2 Improved Progression Module Wide range of comprehensive tools in SOCT CopernicusHR progression module allows doctors to observe pathology progression during follow up visits. New blood vessels recognition system Chorioretinal and Vitreoretinal scanning modes Depending on exam requirements SOCT Copernicus HR software gives you an option to highlight structural changes and to make them more visible in the relevant part of the retina. One Click fast and easy examination Examination Module has been redesigned, now taking an exam is much easier and faster than ever before. With just one click of your mouse system tracks retina and is ready for data acquisition. Network Solutions Reviev Station Server Laptop» Normative Database» Powerful tool for exam reports preparation» New Layer Recognition System» New tools for anterior angle assessment SOCT images can be stored in the central location and be accessible from viewing stations located in many different places. There is no additional charge for the server module. SOCT Copernicus HR High reliability and repeatability thanks to our new blood vessels recognition system. This system allows excellent accuracy in scans overlay.

Age-related Macula Degeneration (AMD) Subfoveal Choroidal NeovascularMembrane Age-related Macula Degeneration (AMD) Epiretinal Membranes Macular Pseudohole Cystoid Macular Edema (CME) Central Serous Chorioretinopathy (CSR) Image courtessy of prof. J. Nawrocki, Jasne Blonia

Image Drusen Epiretinal Membranes Lamellar Macular Hole (LMH) Idiopathic Macular Hole (IMH) SOCT Copernicus HR Wet AMD Retina Schizis Stargardt Disease Vitreomacular Tracion Syndrome (VTS)