Annex-A TECHNICAL SPECIFICATION



Similar documents
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Engine Driven Generators Page 1 of 6

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Generating Set

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Marine Generating Sets 3.7 to 50 kva

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Magnum Mobile Generator MMG55 Specifications

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Power Generation. Power Control PCL System Generator Set Control

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

DIESEL GENERATOR SETS

Atlas Copco Generators

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Spark-ignited generator set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

C18 ACERT Fire Pump Tier bkw/ rpm

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Technical Specification. Generating Set with Waukesha engine burning natural gas

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Single-Phase AC Synchronous Generator

How To Use A Cat Diesel Engine

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

FAIRBANKS NIJHUIS FIRE PUMPS.

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

PM734F - Technical Data Sheet Winding 28

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SELECTION, APPLICATION AND MAINTENANCE

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

The kva RAnge

APS100 Rental Generator Set Specification

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Welcome to Linear Controls Quarterly Training

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

May, ArACBMENT I. Review of. Diesel Generator Alan and Control Circuitry. Indian Point Units No. 2 and 3. Docket Nos.

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

How To Control A Power Command Powerplant

Process Alarm Solutions

Oil and Coolant Circulating Heating System. Model - OCSM

Automatic Voltage Regulator User s Manual

Fire Pump Plan Review March 2010

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

TESTING AND COMMISSIONING PROCEDURE FOR EMERGENCY GENERATOR INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION

Medical Air Systems: Scroll

Electric Flow Boiler

Quick Connect. quick - simple - efficient.

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Generators TEM. for small hydroelectric power stations. Electric Machines

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

3516 Industrial Engine

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Thyristor-controlled power supplies and battery chargers

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Specifying a Variable Frequency Drive s

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

The Yachtmans Choice...

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

PSR The compact range Description

MODEL 2202IQ (1991-MSRP $549.00)

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Transcription:

Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1

1.0 SCOPE This specification covers the requirements of design, manufacture, delivery testing, installation and commissioning of 0.4 kv, 3phase, 50 Hz, 2,000 kva, 1,600 ew, Generator set. 2.0 SITE CONDITIONS 2.1 Ambient Temperature: Maximum 55ºC Minimum -5ºC 2.2 Relative Humidity: Around 60% at maximum Temperature 2.3 Altitude: Around 1000 M above MSL. 3.0 ELECTRICAL SUPPLY PARTICULARS 3.1 System Voltage (Normal): 0.4kV 3.2 No. of Phases: 3 3.3 Frequency: 50 c/s 3.4 Auxiliary supply: 24 V D.C. supplies for D.G Set starting Motor. 4.0 STANDARDS The Diesel Generating set and accessories shall conform to the requirements of Iraq Standards some of are listed below: - a. BS: 649 - Diesel Engines for general purposes b. IS: 4722 - Electrical performance of rotating electrical Machinery. c. IS: 2516 - Air Circuit Breaker d. BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046 5.0 Guarantee period: Contractor shall written guarantee identifying the owner against defective materials and workmanship for a period of one or 1000h actual operation after acceptance. ENGINE: Engine: direct injection, water cooled engine, 16 cylinders, and 4 strokes, rated at 1500 rpm RPM, conforming to ISO 3046 / BS 5514 has the following specifications: - PT fuel pump, Electronic governor - Emission: low fuel consumption - Mechanical unit injector - Holset turbocharger with low temperature after cooler, pulse tuned exhaust Manifold, stainless steel exhaust flexible connections - Radiator or heat exchanger, coolant inhibitor, - Plate type lube oil cooler 2

- Outboard after coolers Full flow paper element filters - fuel, lube oil and by-pass - Dry type replaceable paper element air cleaner with restriction indicator - Flywheel housing & flywheel to suit single / double bearing alternator - Hole set flexible coupling for double bearing alternator - Starting motor Electric, battery charging alternator - Microprocessor based gen set Controller PC - First fill lube oil & coolant inhibitor Full Authority Electronics, - Residential Silencers. ALTERNATOR: Alternator 2,000 kva at 1,500 RPM, 0.4kV, 3 phases conforming to Iraq Standards. The Alternator is brushless alternator. The alternator has the following features - Permanent Magnet - 4 pole - Class H insulation - Salient pole revolving field - Double bearing - PMG standard - Voltage regulation -+ 0.5 % - IP: 23 Enclosures - Digital AVR is inbuilt in PCC. GENSET CONTROLS - is a microprocessor based generator set Monitoring, metering, protection and control system. It shall offer advanced levels of functions for reliability and optimum gen set Performance. The control system shall have easy servicing capabilities that allow system parameters to be interrogated, monitored and adjusted with a PC. Features: - Digital governing - Digital voltage regulation - Protection for true alternator O/C protection - Analog/ digital AC output metering - Battery monitoring system to sense and warn against a weak battery condition - Digital alarm and status message display - Gen set monitoring: Displays status of all critical engines and Generator set functions - Smart starting control system: Integrated fuel ramping to limit black smoke and Frequency overshoot -Advanced serviceability 3

- Network capability MOUNTING ARRANGEMENT: Engine and alternator are mounted on a common MS fabricated base frame. Water proof and sound proof enclosure noise level outside DG room shall not be more than 70 db at distance 1.5m from outside of DG enclosure FUEL TANK: Daily built-in fuel tank. BATTERY: Set of 4 Nos.12 Volts for DG set, uncharged maintenance free batteries with leads and terminals. 6.0 DIESEL ENGINE The Diesel Engine specifications shall be as follows: - 6.1 Type: 4 cycles, V type, Turbo charged and after cooled. 6.2 Rating : Continuous at 55º C ambient, 95% RH & according Iraq atmospheres and pressure. 6.3 No. of Cylinders : 16 6.4 No. of strokes : 4 6.5 BHP : 2,300 kva for 2,000 kva DG set 6.6 RPM : 1,500 6.7 Overload rating : As per BS 5514 6.8 Type of governing : Electronic as per BS 649 6.9 Maximum speed : Not more than 2% Variation on a change Of load up to 20% 6.10 Type of fuel : Diesel 6.11 Fuel consumption : low fuel consumption 6.12 Type of starter: - As per the Manufacturer recommendation. 6.13 Type of Engine : Radiator fan cooled fan to be driven Cooling By the engine shaft. 6.14 Type of coupling to : Direct through flexible coupling Generator 4

7.0 ALTERNATOR The alternator shall be double bearing, revolving field type conforming to IS: 4722 as per specifications given below: - a. Rated voltage : 0.4KV b. Rated KVA : 2,000 kva under site conditions c. Rated power factor : 0.8 d No. Of phases : 3 e. Frequency : 50Hz. f. Type of stator : Star connected Connection g. Percentage regulation : +/- 5% h. Type of excitation : Brushless, Self-regulated and separately Excited, i. Insulation class : Class H for stator and rotor j. Type of enclosure : Screen protected drip proof IP23 k. Alignment : Flex plate/flywheel spigot l. Over speed capability : 150% for 30 sec m. Wave form : Less than 3% deviation n. Paralleling capability : Standard with adjustable voltage drop o. Voltage : 0.4KV p. Voltage regulation : Less than 1% q. Voltage adjustment : ±5% 8.0 AMF WITH AUTO SYNCHRONISING FACILITY AND LOAD SHARING RELAY DEVICE. a. Incomers and Outgoings 8.1 The electronic Microprocessor based AMF module shall contain the following Control and monitoring features. - Automatic/manual start-stop engine control with programmable safety Shutdowns and associated flashing LED indicators for low oil pressure, High coolant temperature, over speed, over crank /rest Periods - Cycle cranking adjustable 1-60 second crank/rest periods. - Cool down timer - adjustable 0-30 minutes. - Energized to run or shut shown fuel control system. - The control panel shall have metering and measuring features like, * Total real power * Total reactive power * % of rated power * Power factor (average) * Total energy output * Real power each phase * Total apparent power * Power factor each phase * Total reactive energy output * Phase selector switch * Auto starts / stops control * Cycle crank and cool down timer * Digital DC Voltmeter * Tachometer, Hour meter * Emergency stop push button * Engine control switch for 5

* Auto, Start / run, off / reset, stop * Engine speed adjust potentiometer * Voltage adjust potentiometer * Digital oil pressure and water temp gauge * Shutoffs with visual indicators for: * Low oil pressure * High water temperature * Over speed * Over crank * Low coolant level * System diagnostic codes * Programmable protective relays a. LCD digital readout for Engine oil pressure, Coolant temperature, Engine RPM, System DC volts, Engine running hours, Generator AC volts, AC Amps and frequency. b. Engine control switch c. Ammeter voltmeter phase selector switch. d. Emergency stop push button. e. Voltage adjustable potential meter. f. Speed adjust potential meter. g. Protective relay functions. - Over voltage - Under voltage - Over frequency - Under frequency - Over current - Reverse power The scope also includes all necessary components which are required for full filament of the system for Auto start, Auto synchronization and load sharing. 13.0 DOCUMENTATION As a part of the equipment supply, following documents shall be supplied for Our/Owners approval/records. Records a. General arrangement drawing of the diesel generating set, engine Outline dimensions and list of Accessories. b. Layout of the diesel generating Sets along with recommended Size and type of D.G enclosure c. Schematic & wiring diagram for gen set e. Routine test certificate on engine 2 for gen set f. Routine test certificate on alternator 2 for gen set 6

g. Routine Test Certificate on VCB and Relays 2 for gen set h. Routine Test Certificate of control Panel 2 for gen set i. Operating instruction chart 2 for gen set j. Instruction Manual 2 for gen set k. Spare parts list 2 for gen set 14.0 PACKING The diesel engine, alternator, control panel etc. shall be suitably packed for Shipment to site by road. A complete list of parts (Packing list) shall be furnished 15.0 SPARES A recommended list of spare parts (for one year operation) of the unit shall be submitted along with the bid. 16.0 PREFERRED MAKES a. Engine CATERPILLAR/ CUMMINS/VOLVO or Equivalent b. Alternator - STAMFORD/LEROY SOMER/MARATHON or Equivalent c. Control Fuses - GE CONTROLS/SIEMENS/C & S f. Battery Approving type 17.0 ASSEMBLY AND INSTALLATION Components shall be assembled in factory over the trailer foundation prepared from other agencies. The necessary fuel and exhaust piping shall be installed as per Bill of quantity. While The fuel piping shall be carried out using medium gauge (class B) MS Pipes, and Approved makes of fittings, the exhaust piping shall be fabricated out of Medium gauge pipes of required diameter. The exhaust gas line shall be insulated up to height 2.5M above the floor level. The pressure loss through Exhaust system does not exceed the value recommended by the manufacturer. Silencers in the exhaust system to maintain the external noise level specified by the manufacturer. The D.G. set shall be installed over the Anti-vibration mounts and the alignment shall be carried out. The alignment shall be well within the limits specified by the manufacturer. The installation of cabling and earthing up to the control panel shall be carried out and this shall comply with the statutory requirements. Any improvement Modification called for the electrical inspectorate shall be carried out 18.0 FIELD TESTING After the assembly the unit shall be tested in the present of the client. The following tests shall be conducted on the engine and alternator. a. Full load test for 8 hours b. Over loading test on engine as per standards 7

c. Fuel & Oil consumption checks d. Determining efficiency e. Meager test on alternator f. Checking regulation g. Testing of control wiring. h. Any other tests as may be required to satisfy the Owner/Electrical inspectorate of the performance of the Unit. 19.0 CONFORMATION SCHEDULE OF TECHNICAL SPECIFICATION Required UNDP specification in Annex: B 20.0 VIBRATION CONTROL The complete generator assembly shall be isolated on static deflection UN housed spring-neoprene in series isolator with non-skid neoprene pads. Start-up and shut down rocking restraint snuffers shall be provided at four Corners of base frame. All fuel line pipes shall be cushioned with a layer of harnesses and neoprene pad At attached points. All pipe work and engine silencers shall be suspended on static deflection spring-neoprene in-series hangers. Detail calculation and proposal for justifying the size and provision shall be provided for consultant Review prior to the installation. 8