More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A



Similar documents
Air Conditioning at its best

york air-conditioning products Residential & VRF News 2015

Inverter Air Conditioning for Light Commercial Use

FULL DC INVERTER SYSTEMS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

DUCTED AIR CONDITIONING SOLUTIONS

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

technology innovation, comfort for your home. The perfect blend of

PRODUCT CATALOG. Indoor Units

M Series. Room Air Conditioning

Pioneer in sustainability

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Samsung Room Air Conditioning

FTXS. Wall Mount Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

-~ available. Power consumption during operation is substantially less than that of lower rated

Air Conditioning for Small and Medium-size Buildings

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

2015 / 16. price list. Airconditioning systems

FTQ. Daikin Inverter Ducted Heat Pump

m-series Ultimate comfort where it matters most Mseries.MrSlim.ca PRODUCT CATALOGUE

Unico Inverter. Unique and efficient.

FBQ. DC Duct Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only

AIR-CONDITIONER SPLIT TYPE

LG Electronics AE Company, Commercial Air Conditioning

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

IR410AI. The flexible solution. Simple, one touch control

LG AIR CONDITIONING SYSTEMS

ECO-AIR AIR CONDITIONING

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Inverter Air Conditioning for Light Commercial Use

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

All the best brands all under one roof

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Installation, operation and maintenance manual TX 35A

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

Air Conditioning and Ventilation Products Single and Multi-Split Systems, VRF and Lossnay

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

2009 AIR CONDITIONING

LOCAL AIR-CONDITIONERS

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

AIR CONDITIONING and HEAT PUMP PRODUCTS

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

CRAC Precision climate control units for data centres

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

2010 Duct-Free Splits Line Card

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Introduction To VRF: System Overview, Applications, & Savings Opportunities

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

innovative comfort solutions

Air Conditioning For Large Buildings

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AIR DEHUMIDIFYING Condensation drying for industry and trade

Cooling kw Heating kw

Split units TH with hermetic compressors

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Air Conditioning & Heat Pump Products

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

NEW 3-PIPE ECOi MF2 SERIES

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Commercial Air Conditioning Systems

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

Operating Instructions Split System Air Conditioner

emura Form. redefined.

elcome to the era of the SEER seasonal efficiency Product range

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

How To Control A Car With A Power Unit

Multi Air Conditioning System for Buildings

Room Air Conditioners

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Transcription:

More than Air Conditioning Catalogue 2004/2005 Air Conditioning Program R 407C R 410A

MITSUBISHI ELECTRIC Air Conditioning Systems As one of the world s leading technology companies, MITSUBISHI ELECTRIC is committed to providing products and solutions which will enhance the quality of our lives at home, at work and at play. Our outstanding range of split and multi-split air conditioning systems reflect this philosophy. Whether you are an installer, specifier or user, you will appreciate the combination of quality, energy-efficiency, reliability and ease-of-installation that MITSUBISHI ELECTRIC Environmental Control products offer.

New technology, more comfort, more energy-efficiency - high-quality air conditioners of MITSUBISHI ELECTRIC! Product series The program offers you more choice than ever before. So whatever the application - a shopping centre, a hotel, restaurant, shop or even a domestic home - the different product series provide the optimum fit. In-ceiling cassettes Contents Units of the M Series are designed for smaller rooms, each outdoor unit requires up to 4 indoor units. M-Series 4 The Mr. Slim Series is applied for middle-sized rooms and is available as single-split and as multi-split system in parallel mode. The City Multi Series convinces with cooling capacity of 14 kw till 84 kw in a refrigerant cycle used for big projects. Wall mounted systems M-Series Accessories Mr. Slim- R407C-Series 24 26 New technology The inverter technology and new refrigerant R410A enable more energy efficiency. All indoor units can be controlled separately for customised adjustment of temperature. Easy installation The environment-friendly systems of MITSUBISHI ELECTRIC can be installed with minimum work. Space-saving and compact units are available for wall or floor mounting - for a flexible planning and design of structures. The air conditioning systems are expandable for subsequent increasing of the capacity at any time. Floor standing units Ceiling suspended systems Mr. Slim- R410A-Series Power Inverter Mr. Slim- Series Accessories City Multi- Series City Multi- Series Accessories 62 70 74 88 Rating conditions COOLING Indoor: 27 C DB / 19 C WB Outdoor: 35 C DB / 24 C WB Outdoor water temperature for WR2 30 C HEATING Indoor: 20 C DB Outdoor: 7 C DB / 6 C WB Outdoor water temperature for WR2 20 C Refrigerant piping length 5 m / 7.5 m* (one way) H = 0 m Sound pressure level measured in anechoic room, at a position 1 m in front of the outdoor unit * For PUH-P8/10MYA and City Multi Above ceiling concealed ducted systems Lossnay Ventilation Series Dehumidifier 94 98 3

M Series Split- and Multi-Split Systems Cooling 2.3 kw - 8.5 kw The outstanding M Series brings legendary Mitsubishi Electric quality to the low-capacity air conditioning class. M Series units are perfect for small living spaces like offices, restaurants and small shops, where their unobtrusive appearance and quiet operation are important advantages. Ultra-energy-efficient M Series systems are designed to give lowest possible running costs, with innovative energy-saving features like `Econo-Cool, which direct airflow towards room occupants. This can allow set temperatures to be raised by 2 C with no loss in comfort and a 20% gain in energy efficiency. 4

Lowest noise levels With noise levels down to just 21 db(a) Excellent control features M Series remote controllers incorporate easy-to-use features like `IFeel control, which memorises the user`s ideal temperature and recreates it precisely. Multi-splits The M Series includes split system models, running up to four indoor units from one outdoor unit. Plus... Optional high-efficiency air cleaning filters; deodorising and antibacterial Catechin filters available for wallmounted systems Rapid room cooling with swing mode feature Remote control of five different angles of airflow to reach ideal temperatures in optimum time A wide range of indoor units and dual-use units for either floor or ceiling installation Quick and easy installation Auto restart function Winterkit in cooling mode up to -15 C for inverter models and a wind-protected installation Range of M Series Cooling Indoor: 21-32 C DB 15-23 C WB Outdoor: 21-43 C DB Non-Inverter models and MXZ-A18 WV -15-43 C DB Inverter types Heating Indoor: 20-27 C DB Outdoor: - 9-21 C DB -10-15 C WB MSC Cooling Only Wall Mounted Systems..................................... 6 MS Cooling Only Wall Mounted Systems...................................... 7 MSC Cooling/Heating Wall Mounted Systems.................................. 8 MSH Cooling/Heating Wall Mounted Systems.................................. 9 MCF Cooling Only Floor or Ceiling Mounted Systems........................... 10 MCFH Cooling/Heating Floor or Ceiling Mounted Systems....................... 11 MSZ Inverter Single Split Cooling/Heating Wall Mounted Systems................. 12 SLZ Inverter Cooling/Heating 4-Ceiling Cassette Systems........................ 14 SEZ Inverter Cooling/Heating Ceiling Concealed Systems....................... 15 MSX Multi Split Systems Cooling Only....................................... 16 MXZ Inverter Multi Split Systems Cooling/Heating.............................. 20 M SERIES Accessories/Optional Parts/Refrigerant............................. 24 5

Series MSC Cooling Only Wall Mounted Systems Energy-saving rotary piston compressor Extremely quiet operation with noise level of only 25 db(a)* `Swing Mode -function enables automatically a more natural and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 * MCS-A07/09YV MSC COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling 2.3 2.55 3.5 AIRFLOW (m 3 /h) Low 276 306 324 High 474 474 582 NOISE db(a) Low 25 25 26 High 36 36 40 WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815 Depth 244 244 244 Height 278 278 278 220-240, 1, 50 RUNNING CURRENT (A) 0.17 0.17 0.19 OUTDOOR UNIT MU-A07YV MU-A09YV MU-A12YV POWER CONSUMPTION (kw) Cooling 0.715 0.795 1.14 AIRFLOW (m 3 /h) 1686 1686 1914 NOISE db(a) 45 45 49 WEIGHT (kg) 34 34 36 DIMENSIONS (mm) Width 780 780 780 Depth 255 255 255 Height 540 540 540 MAX. PIPE LENGTH (m) 20 20 25 MAX. HEIGHT DIFFERENCE (m) 10 10 10 CHARGE R410A* (kg) 0.60 0.60 0.75 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 10 10 12 220-240, 1, 50 RUNNING CURRENT (A) 3.00 3.32 4.92 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 6

Series MS Cooling Only Wall Mounted Systems Energy-saving rotary piston compressor Compact indoor units - easy to install `Swing Mode -function enables automatically a more natural and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 MS COOLING ONLY - WALL MOUNTED SYSTEMS INDOOR UNIT MS-A18WV MS-A24WV MS-A30WV CAPACITY (kw) Cooling 5.0 6.5 8.5 AIRFLOW (m 3 /h) Low 528 588 684 High 768 768 960 NOISE db(a) Low 34 37 37 High 42 45 47 WEIGHT (kg) 16 16 16 DIMENSIONS (mm) Width 1100 1100 1100 Depth 227 227 227 Height 325 325 325 220-240, 1, 50 RUNNING CURRENT (A) 0.30 0.30 0.34 OUTDOOR UNIT MU-A18WV MU-A24WV MU-A30WV POWER CONSUMPTION (KW) Cooling 1.81 2.48 3.26 AIRFLOW (m 3 /h) 2196 2760 2940 NOISE db(a) 52 53 55 WEIGHT (kg) 44 60 85 DIMENSIONS (MM) Width 850 850 840 Depth 290 290 330 Height 605 605 850 MAX. PIPE LENGTH (m) 25 25 30 MAX. HEIGHT DIFFERENCE (m) 10 10 15 CHARGE R410A* (kg) 1.40 1.90 2.30 PIPE SIZE Liquid 6 6 10 ø (mm) Gas 12 16 16 220-240, 1, 50 RUNNING CURRENT (A)) 7.93 10.39 14.42 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 7

Series MSC Cooling/Heating Wall Mounted Systems True comfort year-round Compact indoor units - easy to install Extremely quiet operation with noise level of only 25 db(a)* `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Energy-saving rotary piston compressor Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 * MSC-A07/09YV MSC COOLING/HEATING - WALL MOUNTED SYSTEMS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling 2.3 2.55 3.5 Heating 2.5 3.05 3.9 AIRFLOW (m 3 /h) Low 276 306 324 High 474 474 582 NOISE db(a) Low 25 25 26 High 36 36 40 WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815 Depth 244 244 244 Height 278 278 278 220-240, 1, 50 RUNNING CURRENT (A) 0.17 0.17 0.19 OUTDOOR UNIT MUH-A07YV MUH-A09YV MUH-A12YV POWER CONSUMPTION (kw) Cooling 0.715 0.795 1.09 Heating 0.69 0.84 1.08 AIRFLOW (m 3 /h) 1686 1710 1710 NOISE db(a) 47 49 49 WEIGHT (kg) 35 38 40 DIMENSIONS (mm) Width 780 780 780 Depth 255 255 255 Height 540 540 540 MAX. PIPE LENGTH (m) 20 20 25 MAX. HEIGHT DIFFERENCE (m) 10 10 10 CHARGE R410A* (kg) 0.62 1.00 1.00 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 10 10 12 220-240, 1, 50 RUNNING CURRENT (A) 3.00 3.32 4.65 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 8

Series MSH Cooling/Heating Wall Mounted Systems True comfort year-round Compact indoor units - easy to install `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Energy-saving rotary piston compressor Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction Auto restart function 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Accessories: Additional filters available to keep air fresh, please view page 24 MSH COOLING/HEATING WALL MOUNTED SYSTEMS INDOOR UNIT MSH-A18WV MSH-A24WV MSH-A30WV CAPACITY (kw) Cooling 5.0 6.3 8.5 Heating 5.2 7.2 9.4 AIRFLOW (m 3 /h)) Low 528 588 684 High 768 768 960 NOISE db(a) Low 34 37 37 High 42 45 47 WEIGHT (kg) 16 16 16 DIMENSIONS (mm) Width 1100 1100 1100 Depth 227 227 227 Height 325 325 325 220-240, 1, 50 RUNNING CURRENT (A) 0.30 0.30 0.34 OUTDOOR UNIT MUH-A18WV MUH-A24WV MUH-A30WV POWER Cooling 1.78 2.41 3.26 CONSUMPTION (kw) Heating 1.61 2.48 3.43 AIRFLOW (m 3 /h)) 2196 2760 2940 NOISE db(a) 52 53 55 WEIGHT (kg) 47 74 87 DIMENSIONS (mm) Width 850 840 840 Depth 290 330 330 Height 605 850 850 MAX. PIPE LENGTH (m) 25 25 30 MAX. HEIGHT DIFFERENCE (m) 10 10 15 CHARGE R410A* (kg) 1.75 2.15 2.30 PIPE SIZE Liquid 6 6 10 ø (mm) Gas 12 16 16 220-240, 1, 50 RUNNING CURRENT (A) 7.93 10.39 14.42 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 9

Series MCF Cooling Only Floor or Ceiling Mounted Systems Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension Hand-held controller with `fuzzy logic control Lightweight and compact design for easy installation Readily access for pipe connections and maintenance Quiet operation noise Adjustment of five different angles of airflow direction Three fan-stages or automatic set-up angles of airflow direction `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Auto restart function 24 h Timer Accessories: Additional filters available to keep air fresh, please view page 24 MCF COOLING ONLY - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT MCF-A12WV MCF-A18WV MCF-A24WV CAPACITY (kw) Cooling 3.5 4.8 6.0 AIRFLOW (m 3 /h) Low 474 492 642 High 678 780 840 NOISE db(a) Low 34 36 42 High 44 46 48 WEIGHT (kg) 25 25 25 DIMENSIONS (mm) Width 1100 1100 1100 Depth 180 180 180 Height 650 650 650 220-240, 1, 50 RUNNING CURRENT (A) 0.26 0.36 0.39 OUTDOOR UNIT MU-A12YV MUCF-A18WV MUCF-A24WV POWER CONSUMPTION (kw) Cooling 1.16 1.81 2.45 AIRFLOW (m 3 /h) 1914 2196 2760 NOISE db(a) 49 52 53 WEIGHT (kg) 36 44 60 DIMENSIONS (mm) Width 780 850 850 Depth 255 290 290 Height 540 605 605 MAX. PIPE LENGTH (m) 25 25 25 MAX. HeightNDIFFERENZ (m) 10 10 10 CHARGE R410A* (kg) 0.75 1.2 1.8 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 12 12 16 (V, PHASE,Hz) 220-240, 1, 50 RUNNING CURRENT (A) 4.89 7.92 10.59 * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 10

Series MCFH Cooling/Heating Floor or Ceiling Mounted Systems Versatile 2-in-1 design supplied with multi-purpose brackets for floor-standing or ceiling-suspension Lightweight and compact design for easy installation Comfortable temperature the whole year round Quiet operation noise Hand-held controller with fuzzy-logic control Adjustment of five different angles of airflow direction 24 h Timer Factory charged with refrigerant R410A Readily access for pipe connections and maintenance Three fan-stages or automatic set-up angles of airflow direction Accessories: Additional filters available to keep air fresh, please view page 24 MCFH COOLING/HEATING - FLOOR OR CEILING MOUNTED SYSTEMS INDOOR UNIT MCFH-A12WV MCFH-A18WV MCFH-A24WV CAPACITY (kw) Cooling 3.5 4.8 6.0 Heating 3.7 5.0 6.8 AIRFLOW(m 3 /h) Low 492 570 642 Mittel 636 696 744 High 780 840 840 NOISE db(a) Low 36 39 42 High 46 48 48 WEIGHT (kg) 25 25 25 DIMENSIONS (mm) Width 1100 1100 1100 Depth 180 180 180 Height 650 650 650 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.30 0.36 0.36 OUTDOOR UNIT MUH-A12YV MUCFH-A18WV MUCFH-A24WV POWER Cooling 1.16 1.81 2.45 CONSUMPTION (kw) Heating 1.02 1.89 2.72 AIRFLOW(m 3 /h) 1710 2196 2760 NOISE db(a) 49 52 53 WEIGHT (kg) 40 47 74 DIMENSIONS (mm) Width 780 850 840 Depth 255 290 330 Height 540 605 850 MAX. PIPE LENGTH (m) 25 25 25 MAX. HEIGHT DIFFERENCE (m) 10 10 10 CHARGE R410A* (kg) 1.0 1.75 2.15 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 12 12 16 220-240, 1, 50 RUNNING CURRENT (A) 4.85 8.01 10.51 * Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber 11

Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems Compact indoor units - easy to install Easy and quick cleaning with `Quick Clean Body -system Extremely quiet operation with noise level of only 21 db(a) (MSZ-A09YV) Energy-saving inverter technology provides highest comfort year-round `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Winterkit in cooling mode up to -15 C, view page 5 Accessories: Additional filters available to keep air fresh, please view page 24 Quick clean kit for connection to household vacuum cleaner MSZ INVERTER SINGLE-SPLIT, COOLING/HEATING INDOOR UNIT MSZ-A09YV MSZ-A12YV CAPACITY (kw) Cooling 2.5 (0.9-3.2) 3.5 (1.0-4.1) Heating 3.2 (0.9-5.0) 4.0 (0.9-6.0) AIRFLOW (m 3 /h) Low 222 288 High 504 630 NOISE db(a) Low 21 22 High 37 39 WEIGHT (kg) 9 10 DIMENSIONS (mm) Width 815 815 Depth 244 244 Height 278 278 220-240, 1, 50 RUNNING CURRENT (A) 0.17 0.19 OUTDOOR UNIT MUZ-A09YV MUZ-A12YV POWER Cooling 0.67 1,09 CONSUMPTION (kw) Heating 0.84 1.08 AIRFLOW(m 3 /h) 1900 1900 NOISE db(a) 46 47 WEIGHT (kg) 33 34 DIMENSIONS (mm) Width 800 800 Depth 285 285 Height 550 550 MAX. PIPE LENGTH (m) 20 20 MAX. HEIGHT DIFFERENCE (m) 12 12 CHARGE R410A* (kg) 0.80 0.90 PIPE SIZE Liquid 6 6 ø (mm) Gas 10 10 220-240, 1, 50 RUNNING CURRENT (A) 3.3 5.0 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) 12

Series MSZ Inverter Single-Split Cooling/Heating Wall Mounted Systems Compact indoor units - easy to install Easy and quick cleaning with `Quick Clean Body -system Energy-saving inverter technology provides highest comfort year-round `Swing Mode -function for a quick cooling and comfortable airflow throughout the room Factory charged with refrigerant R410A Hand-held controller with `fuzzy logic control Remote control for five different angles of airflow direction 24 h Timer Long-life and washable Catechin filters for deodorising and prevention of bacteria and viruses Winterkit in cooling mode up to -15 C, view page 5 Accessories: Additional filters available to keep air fresh, please view page 24 MSZ INVERTER SINGLE SPLIT, COOLING/HEATING INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV CAPACITY (kw) Cooling 5.0 (0.9-5.9) 6.0 (0.9-6.7) 7.1 (0.9-8.1) Heating 6.25 (0.9-7.8) 7.0 (0.9-8.1) 8.5 (0.9-9.5) AIRFLOW (m 3 /h) Low 486 510 552 High 828 1020 1020 NOISE db(a) Low 32 33 33 High 47 47 47 WEIGHT (kg) 16 16 16 DIMENSIONS (mm) Width 1100 1100 1100 Depth 258 258 258 Height 325 325 325 220-240, 1, 50 RUNNING CURRENT (A) 0.3 0.3 0.34 OUTDOOR UNIT MUZ-A18YV MUZ-A24YV MUZ-A26YV POWER Cooling 1.56 1.99 2,35 CONSUMPTION (kw) Heating 1.73 2.05 2.65 AIRFLOW (m 3 /h) 2940 2940 2940 NOISE db(a) 55 55 55 WEIGHT (kg) 72 72 80 DIMENSIONS (mm) Width 840 840 840 Depth 330 330 330 Height 850 850 850 MAX. PIPE LENGTH (m) 30 30 30 MAX. HEIGHT DIFFERENCE (m) 15 15 15 CHARGE R410A* (kg) 1.80 2.20 2.35 PIPE SIZE Liquid 6 6 10 ø (mm) Gas 12 16 16 (V, PHASE,Hz) 220-240, 1, 50 RUNNING CURRENT (A) 6.9 8.8 11.0 * Factory charged to 7 m pipe length, optional charging on page 25 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode) Units available approx. July/August 2004 13

Series SLZ Inverter Cooling/Heating In-Ceiling Cassette Systems The standardised Euro-spacing facilitates installation in existing inserted ceilings The required installation height is only 235 mm Quiet operation with noise level of only 32 db(a)* Low weight of 16.5 kg - easy to install Best airflow adjustment by three fan stages Long-life filters to keep air fresh, cleaning necessary only after 2,500 hours of normal operation Equipped with drain pump, delivery height 500 mm Fresh air intake Infrared controller with 12-hours on/off-timer Auto restart function Factory charged with R410A Winterkit in cooling mode up to -15 C, view page 5 * SLZ-A09AR SLZ INVERTER COOLING/HEATING - IN-CEILING CASSETTE SYSTEMS INDOOR UNIT SLZ-A09AR SLZ-A12AR SLZ-A18AR GRILLE SLP-2AL SLP-2AL SLP-2AL CAPACITY (kw) Cooling 2.5 (0.9-3.2) 3.2 (1.0-4.1) 4.3 (0.9-5.0) Heating 3.0 (0.9-3.7) 3.8 (0.9-4.8) 4.8 (0.9-5.6) AIRFLOW (m 3 /h) Low 480 540 540 Middle 540 600 600 High 600 660 660 NOISE db(a) Low 32 34 35 High 38 39 40 WEIGHT (KG) (kg) 16.5/19.5 16.5/19.5 16.5/19.5 DIMENSIONS (mm) Width 570 570 570 Indoor unit Depth 570 570 570 Height* 235 235 235 DIMENSIONS (mm) Width 650 650 650 Grille Depth 650 650 650 Height** 20 20 20 220-240, 1, 50 RUNNING CURRENT (A) 0.4 0.6 0.62 OUTDOOR UNIT SUZ-A09VR SUZ-A12VR SUZ-A18VR POWER Cooling 0.76 1.06 1.53 CONSUMPTION (kw) Heating 0.87 1.07 1.50 AIRFLOW (m 3 /h) 1900 1900 2940 NOISE db(a) 46 47 55 WEIGHT (kg) 33 34 72 DIMENSIONS (mm) Width 800 800 840 Depth 285 285 330 Height 550 550 850 MAX. PIPE LENGTH (m) 20 20 30 MAX. HEIGHT DIFFERENCE (m) 12 12 15 CHARGE R410A*** (kg) 0.8 0.9 1.4 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 10 10 12 220-240, 1, 50 RUNNING CURRENT (A) 3.7 4.9 7.4 *** Required installation height *** Visible height of grille *** Factory charged to 7 m pipe length, optional charging on page 25 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber (cooling mode) 14

Series SEZ Inverter Cooling/Heating Ceiling Concealed Systems Quiet operation of indoor and outdoor units Compact, easy-to-install design (only 270 mm height) Low power consumption for economy of use Direct driven, forward curved centrifugal fan for maximum air throw Self diagnostic trouble shooting function Air intake options for entry at back or base of indoor unit High quality remote control with service display and 12 h-timer Factory charged with refrigerant R410A Auto restart function Winterkit in cooling mode up to -15, view page 5 Air filters PAC-1000 FT included in delivery SEZ INVERTER COOLING/HEATING - CEILING CONCEALED SYSTEMS INDOOR UNIT SEZ-A12AR SEZ-A18AR SEZ-A24AR CAPACITY (kw) Cooling 3.4 (1.0-4.3) 4.7 (0.9-5.6) 5.4 (0.9-6.1) Heating 3.9 (0.9-4.9) 5.7 (0.9-6.6) 6.5 (0.9-7.4) AIRFLOW (m 3 /h) Low 600 720 720 High 780 1020 1200 EXTERNAL STATIC PRESSURE (Pa) 30 (50) 30 (50) 30 (50) NOISE db(a) Low 30 31 32 High 35 39 43 WEIGHT (kg) 33.5 33.5 33.5 DIMENSIONS (mm) Width 1100 1100 1100 Depth 700 700 700 Height 270 270 270 220-240, 1, 50 RUNNING CURRENT (A) 0.59 0.68 0.95 OUTDOOR UNIT SUZ-A12VR SUZ-A18VR SUZ-A24VR POWER Cooling 1.10 1.67 1.92 CONSUMPTION (kw) Heating 1.11 1.78 2.02 AIRFLOW (m 3 /h) 1900 1900 2196 NOISE db(a) 47 55 55 WEIGHT (kg) 34 72 72 DIMENSIONS (mm) Width 800 840 840 Depth 285 330 330 Height 550 850 850 MAX. PIPE LENGTH (m) 20 30 30 MAX. HEIGHT DIFFERENCE (m) 12 15 15 CHARGE* R410A (kg) 0.8 0.9 1.4 PIPE SIZE Liquid 6 6 6 Ø (mm) Gas 10 12 16 220-240, 1, 50 RUNNING CURRENT (A) 5.0 8.0 9.0 * Factory charged to 7 m pipe length, for further information please view page 25 The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 15

Series MSX Multi-Split Cooling Only Wall Mounted Systems Advantages: Cooling capacity between 2.8 kw and 7.3 kw per outdoor unit Up to four wall mounted indoor units with different capacity can be connected for cooling 2, 3 or 4 rooms Independent infrared controller with 24-hours on/off-timer Expandable system, units can be added at any time Multi-Split configurations provide greater economy and comfort due to quiet operation noise, MSC-A07/09 YV only 25 db(a) The energy-saving rotary compressor enables quiet economical performance Auto restart function Refrigerant R410A MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling Depending on combinations, view pages 17-19 AIRFLOW (m 3 /h) Low 276 306 324 High 474 474 582 NOISE db(a) Low 25 25 26 High 36 36 40 WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815 Depth 244 244 244 Height* 278 278 278 220-240, 1, 50 RUNNING CURRENT (A) 0.17 0.17 0.19 POWER CONSUMPTION (W) 35 35 40 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 10 10 12 COMBINATION WITH 2 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT MUX-A10WV MUX-A19WV MUX-A25WV CAPACITY (kw) Cooling 2.8 5.9 7.0 CONNECTABLE INDOOR Number 1-2 1-2 1-2 UNITS Type 2 x 07 1 x 07 + 1 x 12 2 x 12 AIRFLOW (m 3 /h) 1914 2460 2460 NOISE db(a) 49 52 52 WEIGHT (kg) 35 66 68 DIMENSIONS (mm) Width 780 840 840 Depth 255 330 330 Height 540 640 640 TOTAL PIPE LENGTH (m) 30 30 30 MAX. PIPE LENGTH per indoor unit (m) 15 15 15 MAX. HEIGHT DIFFERENCE DIFFERENCE (m) 10 10 10 COMPRESSORS (pc) 1 2 2 CHARGE R410A (kg)* Quantity 0.90 (2 x 0.7) 1.0 (12) 0.95 (12) Apportionment 0.8 (07) 0.95 (12) Charge for (m) 10 (2 x 0.7) 7 (12) 7 (12) Apportionment 7 (07) 7 (12) PIPE SIZE Liquid 2 x 6 2 x 6 2 x 6 ø (mm) Gas 2 x 10 1 x 10/ 1 x 12 2 x 12 (V, Phase, Hz) 220-240, 1, 50 RUNNING CURRENT (A) 3.59 9.32 11.87 POWER CONSUMPTION (kw) 0.8 2.08 2.64 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 16

Series MSX Multi-Split Systems Cooling Only - 2 Wall Mounted Indoor Units Twin Combination: MSX-A10WV 2.8 kw cooling capacity up to 2 connectable indoor units 2 x MSC-A07YV MSC-A07YV MUX-A10WV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A07YV MSC-A07YV 1 indoor unit 2.40 2.40 2 indoor unit 1.40 1.40 MSX-A19WV MSC-A12YV 5.9 kw cooling capacity up to two connectable indoor units 1 x MSC-A07YV 1 x MSC-A12YV MUX-A19WV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A07YV 1 indoor unit 3.50 2.40 2 indoor unit 3.50 2.40 MSX-A25WV 7.0 kw cooling capacity up to two connectable indoor units 2 x MSC-A12YV MSC-A12YV MUX-A25WV MSC-A12YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV 1 indoor unit 3.50 3.50 2 indoor unit 3.50 3.50 17

Series MSX Multi-Split Systems Cooling Only - 3 or 4 Wall Mounted Indoor Units MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kw) Cooling Depending on combinations, view pages 17-19 AIRFLOW (m 3 /h) Low 276 306 324 High 474 474 582 NOISE db(a) Low 25 25 26 High 36 36 40 WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815 Depth 244 244 244 Height 278 278 278 220-240, 1, 50 RUNNING CURRENT (A) 0.17 0.17 0.19 POWER CONSUMPTION (W) 35 35 40 PIPE SIZE Liquid 6 6 6 ø (mm) Gas 10 10 12 COMBINATION WITH 3 OR 4 WALL MOUNTED INDOOR UNITS: OUTDOOR UNIT MUX-A20WV MUX-A22WV MUX-A26WV CAPACITY (kw) Cooling 6.0 6.5 7.3 CONNECTABLE INDOOR Number 1-3 1-3 1-4 UNITS Type 3 x 09 2 x 07 + 1 x 12 2 x 09 + 2 x 12 AIRFLOW (m 3 /h) 2460 2460 2760 NOISE db(a) 52 52 52 WEIGHT (kg) 65 67 77 DIMENSIONS (mm) Width 840 840 840 Depth 330 330 330 Height 640 640 850 TOTAL PIPE LENGTH (m) 45 45 60 MAX. PIPE LENGTH per indoor unit (m) 15 15 15 MAX. HEIGHT DIFFERENCE (m) 10 10 10 COMPRESSORS (pc) 2 2 2 CHARGE R410A (kg)* Quantity 0.80 (09) 0.85 (12) 1.05 (2 x 09) Apportionment 1.0 (2 x 09) 0.85 (2 x 07) 1.05 (2 x 12) Charge for (m) 7 (09) 7 (12) 10 (2 x 09) Apportionment 10 (2 x 09) 10 (2 x 07) 10 (2 x 12) PIPE SIZE Liquid 3 x 6 3 x 6 4 x 6 ø (mm) Gas 3 x 10 2 x 10 / 1 x 12 2 x 10 / 2 x 12 (V, Phase, Hz) 220-240, 1, 50 RUNNING CURRENT (A) 8.92 8.92 10.47 POWER CONSUMPTION incl. indoor units (kw) 1.99 1.98 2.36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber * The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25 18

TRIPLE COMBINATION: MSC-A09YV MSX-A20WV 6.0 kw cooling capacity up to 3 connectable indoor units 3 x MSC-A09YV MUX-A20WV MSC-A09YV MSC-A09YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A09YV MSC-A09YV MSC-A09YV 1 indoor unit 2.60 2.90 2.90 2 indoor unit 2.60 2.80 2.60 2.80 1.75 2.00 3 indoor unit 2.50 1.75 1.75 MSC-A12YV MSX-A22WV 6.5 kw cooling capacity up to 3 connectable indoor units 1 x MSC-A12YV 2 x MSC-A07YV MUX-A22WV MSC-A07YV MSC-A07YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A07YV MSC-A07YV 1 indoor unit 3.50 2.40 2.40 2 indoor unit 3.50 2.40 3.50 2.40 1.45 1.45 3 indoor unit 3.40 1.45 1.45 MSC-A12YV MSX-A26WV 7.3 kw cooling capacity up to 4 connectable indoor units 2 x MSC-A12YV 2 x MSC-A09YV MUX-A26WV MSC-A12YV MSC-A09YV MSC-A09YV COOLING CAPACITY (kw) OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT MSC-A12YV MSC-A12YV MSC-A09YV MSC-A09YV 1 indoor unit 3.40 3.40 2.75 2.75 2 indoor unit 1.95 1.95 3.40 2.70 3.40 2.70 3.40 2.70 3.40 2.70 1.70 1.70 3 indoor unit 1.95 1.95 2.80 1.95 1.95 2.80 3.40 1.70 1.70 3.40 1.70 1.70 4 indoor unit 1.95 1.95 1.70 1.70 19

Series MXZ Inverter Multi-Split Systems Cooling/Heating Energy-saving inverter technology provides highest comfort year-round Very quiet operation Factory charged with R410A Can operate with up to four indoor units connected Various indoor units available: Wall mounted systems, floor or ceiling mounted systems, ceiling concealed system and in-ceiling cassette system Combination of indoor units with different capacity possible Special control retains customised temperature adjustment Auto restart function Winterkit in cooling mode up to -15 C*, view page 5 * for MXZ-A26/32 WV MXZ INVERTER MULTI-SPLIT SYSTEMS COOLING/HEATING OUTDOOR UNIT MXZ-A18WV MXZ-A26WV MXZ-A32WV CAPACITY (kw) Cooling 5.4 (1.55-6.0) 7.2 (2.9-8.5) 8.0 (3.7-9.2) Heating 6.6 (1.58-7.2) 9.0 (2.6-11.0) 9.4 (3.4-11.6) POWER CONSUMPTION Cooling 1.86 (0.37-2.13) 2.09 (0.72-2.56) 2.19 (0.81-2.58) incl. indoor units (kw) Heating 1.77 (0.29-1.85) 2.15 (0.53-3.05) 1.93 (0.59-3.23) AIRFLOW (m3/h) 2460 2630 2630 NOISE db(a) 50 48 48 WEIGHT (kg) 52 69 70 DIMENSIONS (mm) Width 909 900 900 Depth 330 360 360 Height 640 900 900 MAX. PIPE LENGTH per indoor unit (m) 20 25 25 TOTAL PIPE LENGTH (m) 30 50 70 MAX. HEIGHT DIFFERENCE (m) 10 10 10 CHARGE R410A* (kg) 1.75 3.5 3.5 Pipe size Liquid 2 x 6 3 x 6 4 x 6 Ø (mm) Gas 2 x 10 1 x 12 / 2 x 10 2 x 12 / 2 x 10 220-240, 1, 50 RUNNING CURRENT (A) Cooling 8.98 9.18 9.62 Heating 8.55 9.44 8.48 * Factory charged for max. pipe lengths please view page 25 REMARK: The Multi-Split Systems run either cooling or heating mode. At least two indoor units have to be connected. Possible combinations on page 21, 22 and 23. 20

Series MXZ Inverter Multi-Split Systems Cooling/Heating MXZ-A18WV Wall mounted systems: MSC-A07/09/12YV Floor or ceiling mounted systems: MCFH-A12WV Ceiling concealed systems: SEZ-A12AR In-ceiling cassette systems: SLZ-A09/12AR, SLP-2AL (Grille) Combination Mode Capacity (kw) Model A B TOTAL 07 Cooling / HEATING 2.30 / 3.30 / 2.3 (0.90-2.95) / 3.30 (0.90-4.00) 09 Cooling / HEATING 2.50 / 3.60 / 2.5 (0.90-3.30) / 3.60 (0.90-4.50) 12 Cooling / HEATING 3.40 / 4.00 / 3.4 (0.90-4.00) / 4.00 (0.90-4.80) 07+07 Cooling / HEATING 2.30 / 3.05 2.30 / 3.05 4.6 (1.49-5.30) / 6.10 (1.53-6.70) 07+09 Cooling / HEATING 2.30/ 2.97 2.50 / 3.23 4.8 (1.49-5.40) / 6.20 (1.53-6.80) 07+12 Cooling / HEATING 2.02 / 2.62 2.98 / 3.88 5.0 (1.51-5.60) / 6.50 (1.55-7.00) 09+09 Cooling / HEATING 2.50 / 3.25 2.50 / 3.25 5.0 (1.51-5.55) / 6.50 (1.55-7.00) 09+12 Cooling / HEATING 2.20 / 2.78 3.10 / 3.77 5.3 (1.53-5.80) / 6.55 (1.56-7.10) 12 +12 Cooling / HEATING 2.65 / 3.30 2.65 / 3.30 5.4 (1.55-6.00) / 6.60 (1.58-7.20) COMBINATION EXAMPLES MXZ-A18WV - Please refer to the following table for permitted combinations MSC-A12YV SEZ-A12AR MXZ-A18WV SLZ-A09/12AR SLP-2AL (Grille) MCFH-A12WV MXZ-A18WV 21

MXZ-A26WV Wall mounted systems: Floor or ceiling mounted systems: Ceiling concealed systems: In-ceiling cassette systems: MSC-A07/09/12YV, MSH-A18/24WV MCFH-A12/18/24WV SEZ-A12/18/24AR SLZ-A09/12/18AR (grille SLP-2AL) Kombination Model Mode Capacity (kw) A B C Total 7 Cooling/Heating 2.3 / 3.3 2.3 (1.4-3.0) / 3.3 (1.2-4.2) 9 Cooling/Heating 2.5 / 3.6 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 12 Cooling/Heating 3.4 / 4.0 3.4 (1.5-4.3) / 4.0 (1.2-4.8) 18 Cooling/Heating 5.0 / 7.2 5.0 (1.6-5.6) / 7.2 (1.4-8.2) 24 Cooling/Heating 6.0 / 7.9 6.0 (1.6-6.6) / 7.9 (1.4-8.6) 07+07 Cooling/Heating 2.3 / 3.3 2.3 / 3.3 4.6 (2.0-5.4) / 6.6 (1.8-7.2) 07+09 Cooling/Heating 2.1 / 3.02 2.7 / 3.88 4.8 (2.0-5.8) / 6.9 (1.8-8.7) 07+12 Cooling/Heating 2.1 / 2.69 3.6 / 4.61 5.7 (2.0-6.6) / 7.3 (1.8-9.2) 07+18 Cooling/Heating 2.01 / 2.49 5.18/ 6.41 7.2 (2.0-7.7) / 8.9 (1.8-9.9) 07+24 Cooling/Heating 1.62 / 2.03 5.57 / 6.97 7.2 (2.0-8.0) / 9.0 (1.8-9.9) 09+09 Cooling/Heating 2.5 / 3.6 2.5 / 3.6 5.0 (2.0-6.2) / 7.2 (1.8-9.1) 09+12 Cooling/Heating 2.52 / 3.26 3.37 / 4.34 5.9 (2.0-7.3) / 7.6 (1.8-9.5) 09+18 Cooling/Heating 2.4 / 3.0 4.8 / 6.0 7.2 (2.0-8.5) / 9.0 (1.8-10.1) 09+24 Cooling/Heating 1.96 / 2.45 5.23 / 6.55 7.2 (2.0-8.5) / 9.0 (1.8-10.1) 12+12 Cooling/Heating 3.4 / 4.0 3.4 / 4.0 6.8 (2.0-8.5) / 8.0 (1.8-9.8) 12+18 Cooling/Heating 2.88 / 3.6 4.32 / 5.4 7.2 (2.0-8.5) / 9.0 (1.8-10.5) 12+24 Cooling/Heating 2.4 / 3.0 4.8 / 6.0 7.2 (2.0-8.5) / 9.0 (1.8-10.5) 18+18 Cooling/Heating 3.6 / 4.5 3.6 / 4.5 7.2 (2.1-8.5) / 9.0 (1.9-11.0) 18+24 Cooling/Heating 3.08 / 3.86 4.11 / 5.14 7.2 (2.1-8.5) / 9.0 (1.9-11.0) 07+07+07 Cooling/Heating 2.3 / 2.9 2.3 / 2.9 2.3 / 2.9 6.9 (2.9-8.1) / 8.7 (2.6-10.6) 07+07+09 Cooling/Heating 2.16 / 2.67 2.16 / 2.67 2.77 / 3.44 7.1 (2.9-8.5) / 8.8 (2.6-11.0) 07+07+12 Cooling/Heating 1.93 / 2.42 1.93 / 2.42 3.32 / 4.15 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+07+18 Cooling/Heating 1.58 / 1.96 1.58 / 1.96 4.05 / 5.06 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+07+24 Cooling/Heating 1.32 / 1.65 1.32 / 1.65 4.55 / 5.68 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+09+09 Cooling/Heating 2.01 / 2.52 2.59 / 3.24 2.59 / 3.24 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+09+12 Cooling/Heating 1.8 / 2.25 2.31 / 2.89 3.09 / 3.85 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+09+18 Cooling/Heating 1.48 / 1.85 1.9 / 2.38 3.81 / 4.76 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+09+24 Cooling/Heating 1.26 / 1.57 1.62 / 2.02 4.32 / 5.4 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+12+12 Cooling/Heating 1.62 / 2.03 2.79 / 3.48 2.79 / 3.48 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 07+12+18 Cooling/Heating 1.36 / 1.7 2.33 / 2.91 3.5 / 4.37 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 07+12+24 Cooling/Heating 1.17 / 1.46 2.0 / 2.51 4.01 / 5.02 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 07+18+18 Cooling/Heating 1.17 / 1.46 3.01 / 3.76 3.01 / 3.76 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 07+18+24 Cooling/Heating 1.02 / 1.28 2.64 / 3.0 3.52 / 4.4 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 09+09+09 Cooling/Heating 2.36 / 3.0 2.36 / 3.0 2.36 / 3.0 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 09+09+12 Cooling/Heating 2.16 / 2.7 2.16 / 2.7 2.89 / 3.6 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 09+09+18 Cooling/Heating 1.8 / 2.25 1.8 / 2.25 3.6 / 4.5 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 09+09+24 Cooling/Heating 1.45 / 1.92 1.45 / 1.92 4.11 / 5.14 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 09+12+12 Cooling/Heating 1.97 / 2.45 2.61 / 3.27 2.61 / 3.27 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 09+12+18 Cooling/Heating 1.66 / 2.07 2.21 / 2.76 3.32 / 4.15 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 09+12+24 Cooling/Heating 1.44 / 1.8 1.92 / 2.4 3.84 / 4.8 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 09+18+18 Cooling/Heating 1.44 / 1.8 2.88 / 3.6 2.88 / 3.6 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 09+18+24 Cooling/Heating 1.27 / 1.58 2.54 / 3.17 3.38 / 4.23 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 12+12+12 Cooling/Heating 2.4 / 3.0 2.4 / 3.0 2.4 / 3.0 7.2 (2.9-8.5) / 9.0 (2.6-11.0) 12+12+18 Cooling/Heating 2.05 / 2.57 2.05 / 2.57 3.08 / 3.85 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 12+12+24 Cooling/Heating 1.8 / 2.25 1.8 / 2.25 3.6 / 4.5 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 12+18+18 Cooling/Heating 1.8 / 2.25 2.7 / 3.37 2.7 / 3.37 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 12+18+24 Cooling/Heating 1.6 / 2.0 2.4 / 3.0 3.2 / 4.0 7.2 (2.9-8.5) / 9.0 (2.7-11.0) 22

MXZ-A32WV Wall mounted systems: Combination Model Model Capacity (kw) MSC-A07/09/12YV, MSH-A18/24WV Floor or ceiling mounted systems: MCFH-A12/18/24WV Ceiling concealed systems: SEZ-A12/18/24AR In-ceiling cassette systems: SLZ-A09/12/18AR (grille SLP-2AL) Cooling/Heating A B C D Total 7 Cooling/Heating 2.3 / 3.3 2.3 (1.4-3.0) / 3.3 (1.2-4.2) 9 Cooling/Heating 2.5 / 3.6 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 12 Cooling/Heating 3.4 / 4.0 3.4 (1.5-4.3) / 4.0 (1.2-4.8) 18 Cooling/Heating 5.0 / 7.2 5.0 (1.6-5.6) / 7.2 (1.4-8.4) 24 Cooling/Heating 6.0 / 7.9 6.0 (1.6-6.6) / 7.9 (1.4-8.6) 07+07 Cooling/Heating 2.3 / 3.3 2.3 / 3.3 4.6 (2.0-5.4) / 6.6 (1.8-7.2) 07+09 Cooling/Heating 2.1 / 3.02 2.7 / 3.88 4.8 (2.0-5.8) / 6.9 (1.8-8.7) 07+12 Cooling/Heating 2.1 / 2.69 3.6 / 4.61 5.7 (2.0-6.6) / 7.3 (1.8-9.2) 07+18 Cooling/Heating 2.04 / 2.49 5.25 / 6.41 7.3 (2.0-7.7) / 8.9 (1.8-9.9) 07+24 Cooling/Heating 1.75 / 2.12 6.0 / 7.28 7.75 (2.0-8.0) / 9.4 (1.8-9.9) 09+09 Cooling/Heating 2.5 / 3.6 2.5 / 3.6 5.0 (2.0-6.2) / 7.2 (1.8-9.1) 09+12 Cooling/Heating 2.52 / 3.26 3.37 / 4.34 5.9 (2.0-7.3) / 7.6 (1.8-9.5) 09+18 Cooling/Heating 2.5 / 3.0 5.0 / 6.0 7.5 (2.0-8.5) / 9.0 (1.8-10.1) 09+24 Cooling/Heating 2.11 / 2.56 5.64 / 6.84 7.75 (2.0-8.5) / 9.4 (1.8-10.1) 12+12 Cooling/Heating 3.4 / 4.0 3.4 / 4.0 6.8 (2.0-8.8) / 8.0 (1.8-9.8) 12+18 Cooling/Heating 3.1 / 3.76 4.65 / 5.64 7.75 (2.0-8.8) / 9.4 (1.8-10.5) 12+24 Cooling/Heating 2.61 / 3.13 5.24 / 6.27 7.85 (2.0-8.8) / 9.4 (1.8-10.5) 18+18 Cooling/Heating 3.95 / 4.7 3.95 / 4.7 7.9 (2.1-8.8) / 9.4 (1.9-11.2) 18+24 Cooling/Heating 3.42 / 4.03 4.57 / 5.37 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 24+24 Cooling/Heating 4.0 / 4.7 4.0 / 4.7 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 07+07+07 Cooling/Heating 2.3 /2.9 2.3 /2.9 2.3 /2.9 6.9 (2.9-8.1) / 8.7 (2.6-10.6) 07+07+09 Cooling/Heating 2.16 / 2.67 2.16 / 2.67 2.77 / 3.44 7.1 (2.9-8.6) / 8.8 (2.6-11.1) 07+07+12 Cooling/Heating 2.07 / 2.53 2.07 / 2.53 3.55 / 4.33 7.7 (2.9-9.0) / 9.4 (2.6-11.6) 07+07+18 Cooling/Heating 1.72 / 2.05 1.72 / 2.05 4.41 / 5.28 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 07+07+24 Cooling/Heating 1.46 / 1.73 1.46 / 1.73 5.03 / 5.93 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 07+09+09 Cooling/Heating 2.04 / 2.49 2.62 / 3.2 2.62 / 3.2 7.3 (2.9-8.9) / 8.9 (2.6-11.6) 07+09+12 Cooling/Heating 1.93 / 2.35 2.49 / 3.02 3.33 / 4.02 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 07+09+18 Cooling/Heating 1.62 / 1.93 2.09 / 2.48 4.18 / 4.97 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 07+09+24 Cooling/Heating 1.4 / 1.64 1.8 / 2.11 4.8 / 5.64 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 07+12+12 Cooling/Heating 1.77 / 2.12 3.04 / 3.63 3.04 / 3.63 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 07+12+18 Cooling/Heating 1.49 / 1.77 2.56 / 3.04 3.84 / 4.57 7.9 (2.9-9.0) / 9.4 (2.7-11.6) 07+12+24 Cooling/Heating 1.3 / 1.53 2.23 / 2.62 4.46 / 5.24 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 07+18+18 Cooling/Heating 1.3 / 1.53 3.34 / 3.93 3.34 / 3.93 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 07+18+24 Cooling/Heating 1.14 / 1.34 2.93 / 3.45 3.91 / 4.6 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 09+09+09 Cooling/Heating 2.36 / 3.0 2.36 / 3.0 2.36 / 3.0 7.1 (2.9-9.0) / 9.0 (2.6-11.6) 09+09+12 Cooling/Heating 2.32 / 2.82 2.32 / 2.82 3.11 / 3.76 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 09+09+18 Cooling/Heating 1.97 / 2.35 1.97 / 2.35 3.95 / 4.7 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 09+09+24 Cooling/Heating 1.71 / 2.01 1.71 / 2.01 4.57 / 5.37 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 09+12+12 Cooling/Heating 2.15 / 2.56 2.85 / 3.41 2.85 / 3.41 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 09+12+18 Cooling/Heating 1.84 / 2.16 2.46 / 2.89 3.69 / 4.33 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 09+12+24 Cooling/Heating 1.6 / 1.88 2.13 / 2.5 4.26 / 5.01 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 09+18+18 Cooling/Heating 1.6 / 1.88 3.2 / 3.76 3.2 / 3.76 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 09+18+24 Cooling/Heating 1.41 / 1.65 2.82 / 3.31 3.76 / 4.42 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 12+12+12 Cooling/Heating 2.65 / 3.13 2.65 / 3.13 2.65 / 3.13 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 12+12+18 Cooling/Heating 2.28 / 2.68 2.28 / 2.68 3.42 / 4.02 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 12+12+24 Cooling/Heating 2.0 / 2.35 2.0 / 2.35 4.0 / 4.7 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 12+18+18 Cooling/Heating 2.0 / 2.35 3.0 / 3.52 3.0 / 3.52 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 12+18+24 Cooling/Heating 1.77 / 2.08 2.66 / 3.13 3.55 / 4.17 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 07+07+07+07 Cooling/Heating 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 7.8 (3.7-9.2) / 9.4 (3.4-11.6) 07+07+07+09 Cooling/Heating 1.83 / 2.19 1.83 / 2.19 1.83 / 2.19 2.36 / 2.82 7.8 (3.7-9.2) / 9.4 (3.4-11.6) 07+07+07+12 Cooling/Heating 1.68 / 1.99 1.68 / 1.99 1.68 / 1.99 2.91 / 3.41 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 07+07+07+18 Cooling/Heating 1.43 / 1.68 1.43 / 1.68 1.43 / 1.68 3.69 / 4.33 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+07+24 Cooling/Heating 1.24 / 1.46 1.24 / 1.46 1.24 / 1.46 4.26 / 5.01 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+09+09 Cooling/Heating 1.72 / 2.05 1.72 / 2.05 2.2 / 2.64 2.2 / 2.64 7.85 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+09+12 Cooling/Heating 1.59 / 1.88 1.59 / 1.88 2.04 / 2.41 2.72 / 3.22 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 07+07+09+18 Cooling/Heating 1.36 / 1.6 1.36 / 1.6 1.75 / 2.06 3.51 / 4.12 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+09+24 Cooling/Heating 1.19 / 1.4 1.19 / 1.4 1.53 / 1.8 4.08 / 4.8 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+12+12 Cooling/Heating 1.47 / 1.73 1.47 / 1.73 2.52 / 2.96 2.52 / 2.96 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+12+18 Cooling/Heating 1.27 / 1.49 1.27 / 1.49 2.18 / 2.56 3.27 / 3.84 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+12+24 Cooling/Heating 1.12 / 1.31 1.12 / 1.31 1.92 / 2.25 3.84 / 4.51 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+07+18+18 Cooling/Heating 1.12 / 1.31 1.12 / 1.31 2.88 / 3.38 2.88 / 3.38 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 07+09+09+09 Cooling/Heating 1.62 / 1.93 2.09 / 2.48 2.09 / 2.48 2.09 / 2.48 7.9 (3.7-9.2) / 9.4 (3.4-11.6) 07+09+09+12 Cooling/Heating 1.5 / 1.77 1.93 / 2.28 1.93 / 2.28 2.59 / 3.04 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 07+09+09+18 Cooling/Heating 1.3 / 1.53 1.67 / 1.96 1.67 / 1.96 3.34 / 3.93 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+09+09+24 Cooling/Heating 1.14 / 1.34 1.46 / 1.72 1.46 / 1.72 3.91 / 4.60 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+09+12+12 Cooling/Heating 1.4 / 1.64 1.8 / 2.11 2.4 / 2.82 2.4 / 2.82 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 07+09+12+18 Cooling/Heating 1.21 / 1.43 1.56 / 1.83 2.08 / 2.45 3.13 / 3.67 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+09+12+24 Cooling/Heating 1.07 / 1.26 1.38 / 1.62 1.84 / 2.16 3.69 / 4.33 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 07+12+12+12 Cooling/Heating 1.3 / 1.53 2.23 / 2.62 2.23 / 2.62 2.23 / 2.62 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 07+12+12+18 Cooling/Heating 1.14 / 1.34 1.95 / 2.3 1.95 / 2.3 2.93 / 3.45 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 09+09+09+09 Cooling/Heating 1.97 / 2.35 1.97 / 2.35 1.97 / 2.35 1.97 / 2.35 7.9 (3.7-9.2) / 9.4 (3.4-11.6) 09+09+09+12 Cooling/Heating 1.84 / 2.16 1.84 / 2.16 1.84 / 2.16 2.46 / 2.89 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 09+09+09+18 Cooling/Heating 1.6 / 1.88 1.6 / 1.88 1.6 / 1.88 3.2 / 3.76 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 09+09+09+24 Cooling/Heating 1.41 / 1.65 1.41 / 1.65 1.41 / 1.65 3.76 / 4.42 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 09+09+12+12 Cooling/Heating 1.56 / 1.83 1.75 / 2.06 2.34 / 2.75 2.34 / 2.75 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 09+09+12+18 Cooling/Heating 1.5 / 1.76 1.5 / 1.76 2.0 / 2.35 3.0 / 3.52 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 09+12+12+12 Cooling/Heating 1.6 / 1.88 2.13 / 2.5 2.13 / 2.5 2.13 / 2.5 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 12+12+12+12 Cooling/Heating 2.0 / 2.35 2.0 / 2.35 2.0 / 2.35 2.0 / 2.35 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 23

Series Accessories AIR CLEANING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1300FT 10 MSC-A07/09/12YV MSZ-A09/12YV MAC-1700FT 10 MS(H)-A18/24/30WV MAC-1200FT 10 MCF/MCFH DEODORISING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1700DF 10 MCF/MCFH QUICK CLEAN KIT MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-093SS-E1 1 MSZ-A09/12YV Series Refrigerant Charge OUTDOOR UNITS with R410A Mostly factory charged to 7 m pipe length (one-way). Please view the required refrigerant charge for other pipe lengths in the following table. MU-A07/09/12/18/24/30YV/WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MU-A07YV 0.600 0.660 0.760 0.860 MU-A09YV 0.600 0.660 0.760 0.860 MU-A12YV 0.750 0.810 0.910 1.010 1.110 MU-A18WV 1.400 1.460 1.560 1.660 1.760 MU-A24WV 1.900 1.960 2.060 2.160 2.260 MU-A30WV 2.300 2.465 2.740 3.015 3.290 3.465 MUH-A07/09/12/18/24/30YV/WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUH-A07YV 0.620 0.680 0.780 0.880 MUH-A09YV 1.000 1.060 1.160 1.260 MUH-A12YV 1.000 1.060 1.160 1.260 1.360 MUH-A18WV 1.750 1.810 1.910 2.010 2.110 MUH-A24WV 2.150 2.210 2.310 2.410 2.510 MUH-A30WV 2.300 2.465 2.740 3.015 3.290 3.565 MUCFH-A18/24WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m MUCFH-A18WV 1.850 1.910 2.010 2.110 2.210 MUCFH-A24WV 2.200 2.260 2.360 2.460 2.560 24

Series Refrigerant Charge MUZ-A09/12/18/24/26 YV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUZ-A 09 YV 0.860 0.950 1.100 1.250 MUZ-A 12 YV 0.960 1.050 1.200 1.350 MUZ-A 18 YV 1.800 1.860 1.960 2.060 2.160 2.260 MUZ-A 24 YV 1.800 1.860 1.960 2.060 2.160 2.260 MUZ-A 26 YV 2.000 2.165 2.265 2.365 2.465 2.565 SUZ-A09/12/18YV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 7 m 10 m 15 m 20 m 25 m 30 m SUZ-A 09 YV 0.860 0.950 1.100 1.250 SUZ-A 12 YV 0.960 1.050 1.200 1.350 SUZ-A 18 YV 1.800 1.860 1.960 2.060 2.160 2.260 MUX-A10/19/25/20/22/26WV OUTDOOR UNITS Com- Indoor Units CHARGE (ONE-WAY) in kg (MODELS) pressor Models 7 m 10 m 15 m 20 m 25 m 30 m MUX-A10WV 1 2 X MSC-A07YV 0.900* 0.950 1.000 1.050 1.100 MUX-A19WV 1 1 X MSC-A12YV 1.000* 1.060 1.160 1 1 X MSC-A09YV 0.800* 0.860 0.960 MUX-A25WV 1 1 X MSC-A12YV 0.950* 1.010 1.110 1 1 X MSC-A12YV 0.950* 1.010 1.110 MUX-A20WV 1 1 X MSC-A09YV 0.800* 0.860 0.960 1 2 X MSC-A09YV 1.000* 1.050 1.100 1.150 1.200 MUX-A22WV 1 1 X MSC-A12YV 0.850* 0.910* 1.010 1 2 X MSC-A07YV 0.850* 0.900 0.950 1.000 1.050 MUX-A26WV 1 2 X MSC-A09YV 1.050* 1.100 1.150 1.200 1.250 1 2 X MSC-A12YV 1.050* 1.100 1.150 1.200 1.250 * Factory charged MXZ-A18/26/32WV OUTDOOR UNITS CHARGE (ONE-WAY) in kg (MODELS) 20 m 25 m 30 m 40 m 50 m 60 m 70 m MXZ-A18WV 1.750 1.850 1.950 MXZ-A26WV 3.500 3.600 3.700 MXZ-A32WV 3.500 3.600 3.700 3.900 4.100 25

Mr. Slim Series Split- and Multi-Split Systems, R407C Cooling 3.15 kw - 26.0 kw The Mr. Slim Series offers a huge choice of components and configurations for a wide range of applications. The packaged air conditioners are adapted for middlesized rooms, shops, restaurants and offices - for cooling only or with heat pump-function. With ceiling cassettes, ceiling suspended units, wall mounted units and ceiling ducted units, there is a Mr. Slim model which provides the optimum fit for your next job. 26

Advantages of Mr. Slim Wide range of indoor units Simultaneous operation of 2, 3 or 4 indoor units Standard long-life filters Auto change over between cooling and heating mode Heat pump with warm start system Indoor units without electrical heater connectable to heat pump outdoor units A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units. Wired or infrared remote controller optional Maintenance Tool for control and service All models can be interfaced to Building Management Systems by Lon Works Interface Lossnay heat exchange ventilators connectable Factory charged with R407C Winter kit as standard, cooling up to -15 Rating conditions Mr. Slim Series* R407C: Cooling Indoor: 19 C - 35 C DB 15 C - 22.5 C WB Outdoor: -15 C - 46 C DB Heating Indoor: 17 C - 28 C DB Outdoor: -11 C - 24 C DB -12 C - 18 C WB * For PUH-P8/10MYA other rating conditions, please view page 61 COOLING ONLY PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS.........................................28 PLA COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS...............................30 PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS.........................................32 PCA CEILING SUSPENDED SYSTEMS................................................34 PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS......................36 PKA WALL MOUNTED SYSTEMS....................................................38 PSA FLOORSTANDING UNITS.......................................................40 PEAD CEILING CONCEALED SYSTEMS..............................................42 HEAT PUMP UNITS - COOLING AND HEATING PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS........................................44 PLA/PLH COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS..........................46 PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS....................................48 PCA/PCH CEILING SUSPENDED SYSTEMS...........................................50 PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS......................52 PKA/PKH WALL MOUNTED SYSTEMS...............................................54 PSA/PSH FLOORSTANDING UNITS..................................................56 PEAD/PEHD CEILING CONCEALED SYSTEMS........................................58 PEH CEILING CONCEALED SYSTEMS...............................................60 27

Mr. Slim Series PMH Cooling Only 1-Way-In-Ceiling Cassette Systems Simple installation and service, because of compact dimensions installation height only 230 mm Wired remote control Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Standard long-life filter Simple installation and easy access drain and refrigerant piping connections Factory charged with R407C Rotary and scroll compressors Twin, triple and quadruple configuration possible Standard drain pump for 600 mm height differences External airflow prepared 4 fan-stages for comfortable and optimum airflow Accessories: Optional parts on page 70 and the following 28

PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PMH-P1.6 BA PMH-P2 BA CAPACITY (kw) Cooling 4.4 5.4 AIRFLOW (m 3 /h) Low 420 480 Middle 1 480 540 Middle 2 540 600 High 600 660 NOISE db(a) Low 34 36 High 40 42 WEIGHT incl. Grille (kg) 14/17 14/17 DIMENSIONS (mm) Width 854 854 Indoor unit Depth 395 395 Height* 230 230 DIMENSIONS (mm) Width 1000 1000 Grille Depth 470 470 Height** 30 30 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.29 0.29 OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA POWER CONSUMPTION (kw) Cooling 1.6 2.3 AIRFLOW (m 3 /h) 2700 3300 NOISE db(a) 47 48 WEIGHT (kg) 55 71 DIMENSIONS (mm) Width 900 900 Depth 350 350 Height 650 855 MAX. PIPE LENGTH (m) 40 40 MAX. HEIGHT DIFFERENCE (m) 40 40 CHARGE R407C*** (kg) 2.5 2.6 PIPE SIZE Liquid 10 10 ø (mm) Gas 16 16 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, optional charging please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 29

Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems Wired remote control with 24h-timer Compact dimensions Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Drain pump for 500 mm height difference Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth Infrared remote control High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 30

Optional PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KA CAPACITY (kw) Cooling 4.4 5.3 6.3 AIRFLOW (m 3 /h) Low 780 780 840 Middle 1 840 840 900 Middle 2 900 900 960 High 960 960 1020 NOISE db(a) Low 32 32 35 High 37 37 39.5 WEIGHT incl. Grille (kg) 19 / 22.7 19 / 22.7 20 / 23.7 DIMENSIONS (mm) Width 660 660 660 Indoor unit Depth 660 660 660 Height* 298 298 298 DIMENSIONS (mm) Width 760 760 760 (Grille) Depth 760 760 760 Height** 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.64 0.65 0.61 OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAA POWER CONSUMPTION (kw) Cooling 1.8 2.4 2.6 AIRFLOW (m 3 /h) 2700 3300 3000 NOISE db(a) 47 48 48 WEIGHT (kg) 55 71 82 DIMENSIONS (mm) Width 900 900 900 Depth 350 350 350 Height 650 855 855 MAX. PIPE LENGTH (m) 40 40 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 CHARGE R407C*** (kg) 2.5 2.6 3.1 PIPE SIZE Liquid 10 10 10 ø (mm) Gas 16 16 16 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KC PLP-2.5 KLM *** Required installation height *** Visible height of grille *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 31

Mr. Slim Series PLA Cooling Only 4-Way-In-Ceiling Cassette Systems Wired remote control or infrared remote control with 24h-timer Compact dimensions Extremely quiet operation noise, PLA-P3AA just 28 db(a) Weight reduced for PLA-P6AA from 46 kg to only 37 kg Great convenience due to four fan-stages Drain pump for 850 mm height difference Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 32

PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLY INDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AA CAPACITY (kw) Cooling 7.8 9.7 12.8 14.3 AIRFLOW (m 3 /h) Low 900 1200 1320 1320 Middle 1 960 1380 1500 1500 Middle 2 1080 1560 1680 1680 High 1200 1680 1800 1800 NOISE db(a) Low 28 33 35 37 High 34 41 43 45 WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37 DIMENSIONS (mm) Width 840 840 840 840 Indoor unit Depth 840 840 840 840 Height* 258 298 298 298 DIMENSIONS (mm) Width 950 950 950 950 (Grille) Depth 950 950 950 950 Height** 30 30 30 30 (V, phase, Hz) 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.81 1.25 1.43 1.6 OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling 3.4 3.7 5.0 5.9 AIRFLOW (m 3 /h) 3000 5100 5700 6000 NOISE db(a) 49 51 55 57 WEIGHT (kg) 82 96 122 122 DIMENSIONS (mm) Width 900 900 1050 1050 Depth 350 350 350 350 Height 855 1260 1260 1260 MAX. PIPE LENGTH (m) 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 CHARGE R407C*** (kg) 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AAM PLP-6 AALM *** Required installation height *** Visible height of grille *** Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 33

Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems Wired remote control with 24h-timer Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m Rotary and scroll compressors Factory charged with R407C Long-life air filter Great convenience due to four fan-stages Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: High efficiency filter Drain pump Infrared remote control For detailed descriptions please view on page 70 and the following 34

Optional PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GA CAPACITY (kw) Cooling 5.4 6.7 7.5 9.7 12.4 14.3 AIRFLOW (m 3 /h) Low 600 840 840 1200 1620 1620 Middle 1 660 900 900 1260 1800 1800 Middle 2 720 960 960 1380 1920 1920 High 780 1080 1080 1500 2040 2040 NOISE db(a) Low 37 37 37 40 41 42 High 42 43 43 45 46 48 WEIGHT (kg) 27 34 34 37 43 45 DIMENSIONS (mm) Width 1000 1310 1310 1310 1620 1620 Depth 680 680 680 680 680 680 Height 210 210 210 270 270 270 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.43 0.55 0.55 0.7 1.1 1.1 OUTDOOR UNIT PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling 2.4 2.65 3.4 3.64 4.94 5.94 AIRFLOW (m 3 /h) 3300 3000 3000 5100 5700 6000 NOISE db(a) 48 48 49 51 55 57 WEIGHT (kg) 71 82 82 96 122 122 DIMENSIONS (mm) Width 900 900 900 900 1050 1050 Depth 350 350 350 350 350 350 Height 855 855 855 1260 1260 1260 MAX. PIPE LENGTH (m) 40 50 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 50 50 50 50 50 CHARGE R407C* (kg) 2.6 3.1 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 10 10 ø (mm) Gas 16 16 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 3.7 4.5 5.29 5.55 7.6 9.0 * Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 35

Mr. Slim Series PCA Cooling Only Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens The special construction enables easy cleaning of the casing and of all airflow parts Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air Rotary and scroll compressors Factory charged with R407C Wired remote control with 24h-timer Twin configuration possible, on page 72 Accessories: Oil mist filter (12 pcs.) PAC-SG 38 KF-E For detailed descriptions please view on page 70 and the following 36

PCA CEILING SUSPENDED SYSTEMS COOLING ONLY INDOOR UNIT PCA-P3HA PCA-P5HA CAPACITY (kw) Cooling 7.5 13.0 AIRFLOW (m 3 /h) Low 1020 1800 High 1140 2280 NOISE db(a) Low 34 44 High 38 50 WEIGHT (kg) 41 56 DIMENSIONS (mm) Width 1136 1520 Depth 650 650 Height 280 280 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) 0.55 1.1 OUTDOOR UNIT PU-P3YGAA PU-P5YGAA POWER CONSUMPTION (kw) Cooling 3.36 4.90 AIRFLOW (m 3 /h) 3000 5700 NOISE db(a) 49 55 WEIGHT (kg) 82 122 DIMENSIONS (mm) Width 900 1050 Depth 350 350 Height 855 1260 MAX. PIPE LENGTH (m) 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C* (kg) 3.3 4.6 PIPE SIZE Liquid 10 10 ø (mm) Gas 16 18 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.29 7.60 * Factory charged to 30 m pipe length, for further information please view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 37

Mr. Slim Series PKA Cooling Only Wall Mounted Systems Infrared remote control with 24h-timer Slim compact units for wall mounting Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Easily removable long-life air filter PKA-P1.6/2 GAL with four fan-stages Swing louvres with Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 38

Optional PKA WALL MOUNTED SYSTEMS COOLING ONLY INDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FAL CAPACITY (kw) Cooling 4.5 5.6 6.5 7.9 9.5 AIRFLOW (m 3 /h) Low 540 540 900 900 1320 Middle 1 600 600 Middle 2 660 660 High 720 720 1200 1200 1680 NOISE db(a) Low 36 36 39 39 41 High 43 43 45 45 46 WEIGHT (kg) 16 16 24 24 28 DIMENSIONS (mm) Width 990 990 1400 1400 1680 Depth 235 235 235 235 235 Height 340 340 340 340 340 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.33 0.33 0.43 0.43 0.52 OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAA POWER CONSUMPTION (kw) Cooling 1.7 2.4 2.7 3.4 3.6 AIRFLOW (m 3 /h) 2700 3300 3000 3000 5100 NOISE db(a) 47 48 48 49 51 WEIGHT (kg) 55 71 82 82 96 DIMENSIONS (mm) Width 900 900 900 900 900 Depth 350 350 350 350 350 Height 650 855 855 855 1260 MAX. PIPE LENGTH (m) 40 40 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 CHARGE R407C* (kg) 2.5 2.6 3.1 3.3 4.0 PIPE SIZE Liquid 10 10 10 10 10 ø (mm) Gas 16 16 16 16 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 5.3 5.6 * Factory charged to 20 m pipe length, PU-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 39

Mr. Slim Series PSA Cooling Only Floorstanding units Function panel case integrated 24h-timer Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin and triple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 40

PSA FLOORSTANDING UNITS COOLING ONLY INDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GA CAPACITY (kw) Cooling 7.7 9.7 12.4 14.0 AIRFLOW (m 3 /h) Low 900 1440 1560 1620 High 1080 1860 1920 2100 NOISE db(a) Low 40 44 46 47 High 45 49 51 52 WEIGHT (kg) 43 51 51 53 DIMENSIONS (mm) Width 600 600 600 600 Depth 270 350 350 350 Height 1900 1900 1900 1900 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.68 1.1 1.26 1.62 OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAA POWER CONSUMPTION (kw) Cooling 3.4 3.8 5.0 5.8 AIRFLOW (m 3 /h) 3000 5100 5700 6000 NOISE db(a) 49 51 55 57 WEIGHT (kg) 82 96 122 122 DIMENSIONS (mm) Width 900 900 1050 1050 Depth 350 350 350 350 Height 855 1260 1260 1260 MAX. PIPE LENGTH (m) 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 CHARGE R407C* (kg) 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0 * Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 41

Mr. Slim Series PEAD Cooling Only Above-Ceiling Concealed Ducted Systems Wired remote control with 24h-timer Simple installation with easy access drain and refrigerant piping connections PEAD-P1.6/2/2.5 EA airflow variable - draw in from the back or underside Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 42

PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING ONLY INDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EA CAPACITY (kw) Cooling 4.5 5.6 6.7 7.7 9.7 12.3 14.1 AIRFLOW (m 3 /h) Low 660 810 1020 1200 1620 2010 2190 High 840 1020 1260 1500 2040 2520 2760 EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47) High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53) WEIGHT (kg) 33 33 42 44 62 65 70 DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715 Depth 700 700 700 740 740 740 740 Height 295 295 295 325 325 325 325 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.55 0.61 0.7 1.7 2.6 2.7 2.8 OUTDOOR UNIT PU-P1.6YGAA PU-P2YGAA PU-P2.5YGAA PU-P3YGAA PU-P4YGAA PU-P5YGAA PU-P6YGAA POWER CONSUMPTION (kw) Cooling 1.8 2.4 2.7 3.4 3.9 4.9 5.9 AIRFLOW (m 3 /h) 2700 3300 3000 3000 5100 5700 6000 NOISE db(a) 47 48 48 49 51 55 57 WEIGHT (kg) 55 71 82 82 96 122 122 DIMENSIONS (mm) Width 900 900 900 900 900 1050 1050 Depth 350 350 350 350 350 350 350 Height 650 855 855 855 1260 1260 1260 MAX. PIPE LENGTH (m) 40 40 50 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 50 50 CHARGE R407C* (kg) 2.5 2.6 3.1 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 10 10 10 ø (mm) Gas 16 16 16 16 18 18 18 380-415, 3. 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 5.3 5.6 7.6 9.0 ** Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 ** Fan motor optional on page 70 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 43

Mr. Slim Series PMH Cooling / Heating 1-Way-In-Ceiling Cassette Systems Simple installation and service because of compact dimensions - installation height only 230 mm Wired remote control with 24h-timer Quiet operation - only 29 db(a) at PMH-P1 BA Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Standard long-life filter Easy access drain and refrigerant piping connections Factory charged with R407C Rotary and scroll compressors Drain pump for 600 mm height difference External airflow prepared 4 fan-stages for comfortable and optimum airflow Accessories: Optional parts on page 70 and the following 44

PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PMH-P1 BA PMH-P1.6 BA PMH-P2 BA CAPACITY (kw) Cooling 3.15 4.4 5.4 Heating 3.4 5.0 6.25 AIRFLOW (m 3 /h) Low 378 420 480 Middle 1 408 480 540 Middle 2 456 540 600 High 540 600 660 NOISE db(a) Low 29 34 36 High 35 40 42 WEIGHT incl. Grille (kg) 14/17 14/17 14/17 DIMENSIONS (mm) Width 854 854 854 Indoor unit Depth 395 395 395 Height* 230 230 230 DIMENSIONS (mm) Width 1000 1000 1000 Grille Depth 470 470 470 Height** 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.19 0.29 0.29 Heating 0.19 0.29 0.29 OUTDOOR UNIT PUH-P1 VGAA PUH-P1.6 YGAA PUH-P2 YGAA POWER Cooling 1.15 1.6 2.3 CONSUMPTION (kw) Heating 1.06 1.7 2.4 AIRFLOW (m 3 /h) 2700 2700 3300 NOISE db(a) 46 47 48 WEIGHT (kg) 50 55 71 DIMENSIONS (mm) Width 900 900 900 Depth 350 350 350 Height 650 650 855 MAX. PIPE LENGTH (m) 30 40 40 MAX. HEIGHT DIFFERENCE (m) 30 40 40 CHARGE R407C*** (kg) 1.7 2.5 2.6 PIPE SIZE Liquid 6 10 10 ø (mm) Gas 12 16 16 220-240, 1, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 4.9 2.5 3.7 Heating 4.5 2.6 3.8 GRILLE-TYPE FOR WIRED REMOTE CONTROL PMP-40 BM *** Required installation height *** Visible installation height *** Factory charged to 20 m pipe length, for further information please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 45

Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems Wired remote control with 24h-timer PLH units with additional electrical heating for a warm start and to increase capacity of heat pump 4 fan-stages for best comfort Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Adjustable air outlets for optimum airflow for ceiling heights up to 3.8 m Standard long-life filter Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Drain pump for 500 mm height difference Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth Infrared remote control High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 46

Optional PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KA INDOOR UNIT WITH ELECTRICAL HEATING PLH-P1.6 KAH PLH-P2 KAH PLH-P2.5 KAH CAPACITY (kw) Cooling 4.4 5.3 6.3 Heating* 5.0 (6.4) 6.0 (7.4) 7.4 (9.5) AIRFLOW (m 3 /h) Low 780 780 840 Middle 1 840 840 900 Middle 2 900 900 960 High 960 960 1020 NOISE db(a) Low 32 32 35 High 37 37 39.5 WEIGHT PLA incl. Grille (kg) 19 / 22.7 19 / 22.7 20 / 23.7 WEIGHT PLH incl. Grille (kg) 20 / 23.7 20 / 23.7 21 / 24.7 DIMENSIONS (mm) Width 660 660 660 Indoor unit Depth 660 660 660 Height** 298 298 298 DIMENSIONS (mm) Width 760 760 760 Grille Depth 760 760 760 Height*** 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.64 0.65 0.61 Heating* 0.45 (5.83) 0.45 (5.83) 0.45 (8.75) OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAA POWER CONSUMPTION (kw) Cooling 1.8 2.4 2.6 Heating* 1.9 (3.3) 2.4 (3.8) 2.6 (4.7) AIRFLOW (m 3 /h) 2700 3300 3000 NOISE db(a) 47 48 48 WEIGHT (kg) 55 71 82 DIMENSIONS (mm) Width 900 900 900 Depth 350 350 350 Height 650 855 855 MAX. PIPE LENGTH (m) 40 40 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 CHARGE R407C**** (kg) 2.5 2.6 3.1 PIPE SIZE Liquid 10 10 10 ø (mm) Gas 16 16 16 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 Heating 2.6 3.8 4.3 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KC PLP-2.5 KLM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz 47

Mr. Slim Series PLA Cooling / Heating PLH Cooling / Heating 4-Way-In-Ceiling Cassette Systems Wired remote control or infrared remote control with 24h-timer PLH units with additional electrical heating for a warm start and to increase capacity of heat pump Compact dimensions Extremely quiet operation noise, PLA-P3AA just 28 db(a) Weight reduced for PLA-P6AA from 46 kg to only 37 kg 4 fan-stages for best comfort Drain pump for 850 mm height difference Simple installation with easy access drain and refrigerant piping connections Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Rotary and scroll compressors Factory charged with R407C Long-life air filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Space panel enables installation into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 48

PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AA INDOOR UNIT WITH ELECTRICAL HEATING PLH-P3 AAH PLH-P4 AAH PLH-P5 AAH PLH-P6 AAH CAPACITY (kw) Cooling 7.8 9.7 12.8 14.3 Heating* 9.3 (11.4) 10.6 (12.7) 14.9 (17.9) 17.1 (20.1) AIRFLOW (m 3 /h) Low 900 1200 1320 1320 Middle 1 960 1380 1500 1500 Middle 2 1080 1560 1680 1680 High 1200 1680 1800 1800 NOISE db(a) Low 28 33 35 37 High 34 41 43 45 WEIGHT PLA incl. Grille (kg) 24/29 30/35 30/35 32/37 WEIGHT PLA incl. Grille (kg) 26/31 32/37 32/37 34/39 DIMENSIONS (mm) Width 840 840 840 840 Indoor unit Depth 840 840 840 840 Height** 258 298 298 298 DIMENSIONS (mm) Width 950 950 950 950 Grille Depth 950 950 950 950 Height*** 30 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.81 1.25 1.43 1.64 Heating* 0.81 (8.75) 1.25 (10.83) 1.43 (12.5) 1.64 (12.5) OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER CONSUMPTION (kw) Cooling 3.4 3.7 5.0 5.9 Heating* 3.5 (5.6) 3.9 (6.0) 5.3 (8.3) 6.4 (9.4) AIRFLOW (m 3 /h) 3000 5100 5700 6000 NOISE db(a) 49 51 55 57 WEIGHT (kg) 82 96 122 122 DIMENSIONS (mm) Width 900 900 1050 1050 Depth 350 350 350 350 Height 855 1260 1260 1260 MAX. PIPE LENGTH (m) 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 CHARGE R407C**** (kg) 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0 Heating 5.6 5.9 8.2 9.6 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AAM PLP-6 AALM **** Values given in brackets incl. additional electrical heating **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. 49

Mr. Slim Series PCA Cooling / Heating PCH Cooling / Heating Ceiling Suspended Systems Wired remote control with 24h-timer PCH units with additional electrical heating for a warm start and to increase capacity of heat pump Adjustable air outlets for optimum airflow for ceiling heights up to 3.5 m Rotary and scroll compressors Factory charged with R407C Long-life air filter 4 fan-stages for optimum comfort Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: High efficiency filter Drain pump Infrared remote control For detailed descriptions please view on page 70 and the following 50

Optional PCA/PCH CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GA INDOOR UNIT WITH ELECTRICAL HEATING PCH-P2 GAH PCH-P2.5 GAH PCH-P3 GAH PCH-P4 GAH PCH-P5 GAH PCH-P6 GAH CAPACITY (kw) Cooling 5.4 6.7 7.5 9.7 12.4 14.3 Heating* 6.3 (7.7) 7.3 (9.4) 9.2 (11.3) 10.6 (13.4) 14.9 (17.9) 17.1 (20.1) AIRFLOW (m 3 /h) Low 600 840 840 1200 1620 1620 Middle 1 660 900 900 1260 1800 1800 Middle 2 720 960 960 1380 1920 1920 High 780 1080 1080 1500 2040 2040 NOISE db(a) Low 37 37 37 40 41 42 High 42 43 43 45 46 48 WEIGHT PCA (kg) 27 34 34 37 43 45 WEIGHT PCH (kg) 28.5 36 36 39.5 46 48 DIMENSIONS (mm) Width 1000 1310 1310 1310 1620 1620 Depth 680 680 680 680 680 680 Height 210 210 210 270 270 270 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.43 0.55 0.55 0.7 1.1 1.1 Heating* 0.43 (5.83) 0.55 (8.75) 0.55 (8.75) 0.7 (11.25) 1.1 (12.5) 1.1 (12.5) OUTDOOR UNIT PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER Cooling 2.4 2.65 3.4 3.6 4.9 5.9 CONSUMPTION (kw) Heating* 2.4 (3.8) 2.7 (4.8) 3.5 (5.6) 3.8 (6.55) 5.1 (8.1) 6.3 (9.3) AIRFLOW (m 3 /h) 3300 3000 3000 5100 5700 6000 NOISE db(a) 48 48 49 51 55 57 WEIGHT (kg) 71 82 82 96 122 122 DIMENSIONS (mm) Width 900 900 900 900 1050 1050 Depth 350 350 350 350 350 350 Height 855 855 855 1260 1260 1260 MAX. PIPE LENGTH (m) 40 50 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 50 50 50 50 50 CHARGE R407C** (kg) 2.6 3.1 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 10 10 ø (mm) Gas 16 16 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 3.7 4.5 5.3 5.5 7.6 9.0 Heating 3.8 4.3 5.6 5.8 8.1 9.6 ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 51

Mr. Slim Series PCA Cooling / Heating Ceiling Suspended Systems For Applications In Kitchens The established ceiling suspended system consisting of stainless steel for applications in kitchens The special construction enables easy cleaning of the casing and of all airflow parts Oil particles can be filtered 1.5 times more efficient compared to conventional types due to high performance filter (optional) On the rear panel round knockout opening (Ø 200 mm) allows more comfort by supplying fresh air Rotary and scroll compressors Factory charged with R407C Wired remote control with 24h-timer Twin configuration possible, on page 72 Accessories: Oil mist filter (12 pcs.) PAC-SG 38 KF-E For detailed descriptions please view on page 70 and the following 52

PCA CEILING SUSPENDED SYSTEMS COOLING / HEATING INDOOR UNIT PCA-P3 HA PCA-P5 HA CAPACITY (kw) Cooling 7.5 13.0 Heating 9.2 16.0 AIRFLOW (m 3 /h) Low 1020 1800 High 1140 2280 NOISE db(a) Low 34 44 High 38 50 WEIGHT (kg) 41 56 DIMENSIONS (mm) Width 1136 1520 Depth 650 650 Height 280 280 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) 0.55 1.1 OUTDOOR UNIT PUH-P3 YGAA PUH-P5 YGAA POWER Cooling 3.36 4.90 CONSUMPTION (kw) Heating 3.41 4.98 AIRFLOW (m 3 /h) 3000 5700 NOISE db(a) 49 55 WEIGHT (kg) 82 122 DIMENSIONS (mm) Width 900 1050 Depth 350 350 Height 855 1260 MAX. PIPE LENGTH (m) 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C* (kg) 3.3 4.6 PIPE SIZE Liquid 10 10 ø (mm) Gas 16 18 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.30 7.60 Heating 5.60 8.10 * Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 53

Mr. Slim Series PKA Cooling / Heating PKH Cooling / Heating Wall Mounted Systems Infrared remote control with 24h-timer PKH units with additional electrical heating for a warm start and to increase capacity of heat pump Slim compact units for wall mounting Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Easily removable long-life air filter PKA/H-P1.6/2 GAL/H with 4 fan-stages Swing louvres with `Auto Angle airflow Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 54

Optional PKA/PKH WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FAL INDOOR UNIT WITH ELECTRICAL HEATING PKH-P1.6 GALH PKH-P2 GALH PKH-P2.5 FALH PKH-P3 FALH PKH-P4 FALH CAPACITY (kw) Cooling 4.5 5.4 6.5 7.9 9.5 Heating* 5.0 (5.8) 6.3 (7.1) 7.4 (9.5) 9.5 (11.6) 10.9 (13.3) AIRFLOW (m 3 /h) Low 540 540 900 900 1320 Middle 1 600 600 Middle 2 660 660 High 720 720 1200 1200 1680 NOISE db(a) Low 36 36 39 39 41 High 43 43 45 45 46 WEIGHT PKA (kg) 16 16 24 24 28 WEIGHT PKH (kg) 17 17 26 26 30 DIMENSIONS (mm) Width 990 990 1400 1400 1680 Depth 235 235 235 235 235 Height 340 340 340 340 340 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.33 0.33 0.43 0.43 0.52 Heating* 0.33 (3.3) 0.33 (3.3) 0.43 (8.75) 0.43 (8.75) 0.52 (10.0) OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAA POWER Cooling 1.7 2.4 2.7 3.4 3.6 CONSUMPTION (kw) Heating* 1.9 (2.7) 2.4 (3.2) 2.6 (4.7) 3.6 (5.7) 3.8 (6.2) AIRFLOW (m 3 /h) 2700 3300 3000 3000 5100 NOISE db(a) 47 48 48 49 51 WEIGHT (kg) 55 71 82 82 96 DIMENSIONS (mm) Width 900 900 900 900 900 Depth 350 350 350 350 350 Height 650 855 855 855 1260 MAX. PIPE LENGTH (m) 40 40 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 CHARGE R407C** (kg) 2.5 2.6 3.1 3.3 4.0 PIPE SIZE Liquid 10 10 10 10 10 ø (mm) Gas 16 16 16 16 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.3 5.3 5.6 Heating 2.6 3.8 4.5 5.6 5.9 ** Values given in brackets incl. additional electrical heating ** Factory charged to 20 m pipe length, PUH-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 55

Mr. Slim Series PSA Cooling / Heating PSH Cooling / Heating Floorstanding units Function panel case integrated and 24h-timer PSH units with additional electrical heating for a warm start and to increase capacity of heat pump Compact design and high capacity Simple installation with easy access drain and refrigerant piping connections Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin and triple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 56

PSA/PSH FLOORSTANDING UNITS COOLING / HEATING INDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GA INDOOR UNIT WITH ELECTRICAL HEATING PSH-P3 GAH PSH-P4 GAH PSH-P5 GAH PSH-P6 GAH CAPACITY (kw) Cooling 7.7 9.7 12.4 14.0 Heating* 9.3 (11.4) 10.9 (13.6) 14.6 (17.6) 17.1 (20.1) AIRFLOW (m 3 /h) Low 900 1440 1560 1620 High 1080 1860 1980 2100 NOISE db(a) Low 40 44 46 47 High 45 49 51 52 WEIGHT PSA (kg) 43 51 51 53 WEIGHT PSH (kg) 45 53 53 55 DIMENSIONS (mm) Width 600 600 600 600 Depth 270 350 350 350 Height 1900 1900 1900 1900 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.68 1.1 1.26 1.62 Heating* 0.68 (8.75) 1.1 (11.25) 1.26 (12.5) 1.62 (12.5) OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAA POWER Cooling 3.4 3.8 5.0 5.8 CONSUMPTION (kw) Heating* 3.5 (5.6) 3.9 (6.6) 5.4 (8.4) 6.1 (9.1) AIRFLOW (m 3 /h) 3000 5100 5700 6000 NOISE db(a) 49 51 55 57 WEIGHT (kg) 82 96 122 122 DIMENSIONS (mm) Width 900 900 1050 1050 Depth 350 350 350 350 Height 855 1260 1260 1260 MAX. PIPE LENGTH (m) 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 CHARGE R407C** (kg) 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0 Heating 5.6 5.9 8.1 9.6 ** Values given in brackets incl. additional electrical heating ** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1 m in front of and 1 m above. 57

Mr. Slim Series PEAD Cooling / Heating PEHD Cooling / Heating Above-Ceiling Concealed Ducted Systems Wired remote control with 24h-timer PEHD units with additional electrical heating for a warm start and to increase capacity of heat pump Simple installation with easy access drain and refrigerant piping connections PEAD/PEHD-P1.6/2/2.5 EA/H airflow variable - draw in from the back or underside Rotary and scroll compressors Factory charged with R407C Standard long-life filter Twin, triple, quadruple configuration possible, on page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 58

PEAD/PEHD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EA INDOOR UNIT W. ELECTRICALHEATING PEHD-P1.6EAH PEHD-P2EAH PEHD-P2.5EAH PEHD-P3EAH PEHD-P4EAH PEHD-P5EAH PEHD-P6EAH CAPACITY (kw) Cooling 4.5 5.6 6.7 7.7 9.7 12.3 14.1 Heating* 4.9 (5.9) 6.2 (7.2) 7.2 (8.7) 9.1 (11.2) 10.4 (12.9) 13.9 (16.9) 16.7 (19.7) AIRFLOW (m 3 /h) Low 660 810 1020 1200 1620 2100 2190 High 840 1020 1260 1500 2040 2520 2760 EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47) High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53) WEIGHT PEAD (kg) 33 33 42 44 62 65 70 WEIGHT PEHD (kg) 35 35 44 46 65 68 73 DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715 Depth 700 700 700 740 740 740 740 Height 295 295 295 325 325 325 325 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.55 0.63 0.7 1.7 2.6 2.7 2.8 Heating* 0.55 (4.71) 0.63 (4.8) 0.7 (7.0) 1.7 (10.4) 2.6 (12.6) 2.7 (15.2) 2.8 (15.2) OUTDOOR UNIT PUH-P1.6YGAA PUH-P2YGAA PUH-P2.5YGAA PUH-P3YGAA PUH-P4YGAA PUH-P5YGAA PUH-P6YGAA POWER Cooling 1.8 2.4 2.7 3.4 3.9 4.9 5.9 CONSUMPTION (kw) Heating* 1.8 (2.8) 2.2 (3.2) 2.5 (4.0) 3.2 (5.3) 4.0 (6.5) 4.8 (7.8) 6.0 (9.0) AIRFLOW (m 3 /h) 2700 3300 3000 3000 5100 5700 6000 NOISE db(a) 47 48 48 49 51 55 57 WEIGHT (kg) 55 71 82 82 96 122 122 DIMENSIONS (mm) Width 900 900 900 900 900 1050 1050 Depth 350 350 350 350 350 350 350 Height 650 855 855 855 1260 1260 1260 MAX. PIPE LENGTH (m) 40 40 50 50 50 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 50 50 CHARGE R407C*** (kg) 2.5 2.6 3.1 3.3 4.0 4.6 4.9 PIPE SIZE Liquid 10 10 10 10 10 10 10 ø (mm) Gas 16 16 16 16 18 18 18 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 2.5 3.7 4.3 5.3 5.6 7.6 9.0 Heating 2.6 3.8 4.5 5.6 5.9 8.2 9.6 *** Values given in brackets incl. additional electrical heating *** Fan motor optional on page 70 *** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. 59

Mr. Slim Series PEH Cooling / Heating Concealed Ducted Systems Wired remote control with 24h-timer Pressure to 150 Pa PUH-P8/10 MYA for simultaneous operation of Mr. Slim indoor units Factory charged with R407C Twin, triple, quadruple configuration possible, on page 72 Accessories: Optional parts on page 70 and the following 60

PEH CONCEALED DUCTED SYSTEMS COOLING/HEATING INDOOR UNIT PEH-P8 MYA PEH-P10 MYA CAPACITY (kw) Cooling 20.9 26.0 Heating 23.7 30.5 AIRFLOW (m 3 /h) 3600 4800 EXTERNAL STATIC PRESSURE (Pa) 50/150 50/150 NOISE db(a) 53 57 WEIGHT (kg) 74 80 DIMENSIONS (mm) Width 1580 1580 Depth 604 604 Height 455 455 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 1.1 1.6 Heating 1.1 1.6 OUTDOOR UNIT PUH-P8 MYA PUH-P10 MYA POWER Cooling 7.92 9.96 CONSUMPTION (kw) Heating 7.82 9.56 AIRFLOW (m 3 /h) 11100 11100 NOISE db(a) 56 57 WEIGHT (kg) 215 220 DIMENSIONS (mm) Width 990 990 Depth 840 840 Height 1715 1715 MAX. PIPE LENGTH (m) 50 50 MAX. HEIGHT DIFFERENCE (m) 40 40 CHARGE R407C* (kg) 6.0 6.5 PIPE SIZE Liquid 12 12 ø (mm) Gas 28 28 380-415, 3, 50 380-415, 3, 50 RUNNING CURRENT (A) Cooling 13 16 Heating 12.8 15.4 * Factory charged, please view page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Rating conditions: COOLING Indoor: 15 C - 24 C WB Outdoor: -15 C - 46 C DB HEATING Indoor: 15 C - 27 C WB Outdoor: -12 C - 18 C DB 61

Mr. Slim R410A-Series Power Inverter Split and Multi-Split Systems The established Mr. Slim Series with inverter technology - efficient, economical and very quiet. 62

Advantages of Mr. Slim R410A-Series Power Inverter New inverter-technology and refrigerant R410A enable high energy-efficiency The wide range of performance allows an optimum of convenience - for a quick cooling and heating All outdoor units with LOW NOISE - mode, only 44 db(a) at PUHZ-RP3VHA The indoor units RP can be connected with Mr. Slim R407C outdoor units Multi Split simultaneous operation Standard long-life filters Auto change over between cooling and heating mode A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units. Error codes are shown at remote controls display of indoor units Lossnay heat exchange ventilators connectable Factory charged with refrigerant R410A Wired or infrared remote controller optional Remote monitoring Maintenance Tool for control and service All models can be interfaced to Building Management Systems by Lon Works Interface Ceiling cassette models with condensate pump Winter kit as standard, cooling up to -15 C. If the unit is placed in wind direction use the optional part, view page 70 and the following Rating conditions Mr. Slim Series: COOLING Indoor: 19 C - 35 C DB 15 C - 22.5 C WB Outdoor: -15 C - 46 C DB HEATING Indoor: 17 C - 28 C DB Outdoor: -11 C - 24 C DB -12 C - 18 C WB NEW! POWER INVERTER- HEAT PUMP UNITS PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS..........................................64 PKA WALL-MOUNTED SYSTEMS.....................................................66 PEAD CEILING CONCEALED SYSTEMS...............................................68 63

Mr. Slim Power Inverter PLA Cooling / Heating 4-Way-In-Ceiling Cassette Systems NEW! Wired or infrared remote control with 24h-timer provided Space-saving, quadratic design Installation height only 258 mm (PLA-RP3 AA) Quiet operation noise - just 28 db(a) (PLA-RP3 AA) Drain pump for 850 mm height difference Prepared duct connections: round 150 mm, rectangular 350 x 100 mm 4 fan-stages for best comfort Precisely directed airflow to prevent dirt built-up and staining of ceiling tiles Adjustable air outlets for optimum airflow for ceiling heights up to 4.2 m Standard long-life filter - cleaning necessary every 2,500 operating hours Simple installation with easy access drain and refrigerant piping connections Factory charged with R410A Rotary and scroll compressors Multi Split simultaneous operation, view page 72 Accessories: Space panel for installation of PLA-RP4/5/6AA into ceiling void of just 258 mm depth High efficiency filter and external airflow For detailed descriptions please view on page 70 and the following 64

POWER INVERTER PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATING INDOOR UNIT PLA-RP3 AA PLA-RP4 AA PLA-RP5 AA PLA-RP6 AA CAPACITY COOLING (Min. - Nominal - Max.) kw 3.3-7.1-8.1 5.0-10.0-11.4 6.0-12.5-14.0 6.2-14.0-15.3 CAPACITY HEATING (Min. - Nominal - Max.) kw 3.5-8.0-10.2 5.6-11.2-14.0 6.0-14.0-16.0 6.2-16.0-18.0 COP Cooling/Heating 3.60/3.42 3.30/3.30 3.21/3.28 2.81/3.26 AIRFLOW (m 3 /h) Low 900 1200 1320 1320 Middle 1 960 1380 1500 1500 Middle 2 1080 1560 1680 1680 High 1200 1680 1800 1800 NOISE db(a) Low 28 33 37 37 High 34 41 45 45 WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37 DIMENSIONS (mm) Width 840 840 840 840 Indoor unit Depth 840 840 840 840 Height** 258 298 298 298 DIMENSIONS (mm) Width 950 950 950 950 Grille Depth 950 950 950 950 Height*** 30 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.79 1.25 1.43 1.6 Heating 0.79 1.25 1.43 1.6 OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA POWER Cooling 1.97 3.03 3.89 4.99 CONSUMPTION (kw) Heating 2.34 3.39 4.27 4.91 AIRFLOW (m 3 /h) 3300 6000 6000 6000 NOISE db(a) 44*/47 46*/49 47*/50 48*/50 WEIGHT (kg) 75 121 121 121 DIMENSIONS (mm) Width 950 900 900 900 Depth 360 360 360 360 Height 943 1350 1350 1350 MAX. PIPE LENGTH (m) 50 75 75 75 MAX. HEIGHT DIFFERENCE (m) 30 30 30 30 CHARGE R410A**** (kg) 3.5 5.5 5.5 5.5 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 16 16 16 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 8.0 12.3 15.8 20.3 Heating 9.7 13.9 17.5 20.7 CIRCUIT BREAKER (A) 25 32 32 40 GRILLE-TYPE FOR WIRED REMOTE CONTROL GRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6AAM PLP-6AALM **** LOW NOISE mode **** Required installation height **** Visible height of grille **** Factory charged to 30 m pipe length, optional charging on page 73 The noise levels are measured at a position 1.5 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 65

Mr. Slim Power Inverter PKA Cooling / Heating Wall Mounted Systems NEW! Infrared remote control with 24h-timer Slim compact units for wall mounting Flexible louvre for evenly spread of air Simple installation with easy access drain and refrigerant piping connections Easily removable long-life air filter Factory charged with R407C Rotary and scroll compressors Multi Split simultaneous operation possible, page 72 Accessories: Drain pump Wired remote control For detailed descriptions please view on page 70 and the following 66

Optional POWER INVERTER PKA WALL MOUNTED SYSTEMS COOLING / HEATING INDOOR UNIT PKA-RP3FAL PKA-RP4FAL CAPACITY COOLING (Min. - Nominal - Max.) kw 3.3-7.1-8.1 5.0-10.0-11.4 CAPACITY HEATING (Min. - Nominal - Max.) kw 3.5-8.0-10.2 5.6-11.2-14.0 COP Cooling/Heating 3.59 / 3.33 3.41 / 3.45 AIRFLOW (m 3 /h) Low 900 1320 High 1200 1680 NOISE db(a) Low 39 41 High 45 46 WEIGHT (kg) 24 28 DIMENSIONS (mm) Width 1400 1680 Depth 235 235 Height 340 340 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 0.43 0.52 Heating 0.43 0.52 OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA POWER Cooling 1.98 2.93 CONSUMPTION (kw) Heating 2.40 3.25 AIRFLOW (m 3 /h) 3300 6000 NOISE db(a) 44*/47 46*/49 WEIGHT (kg) 75 121 DIMENSIONS (mm) Width 950 950 Depth 360 360 Height 943 1350 MAX. PIPE LENGTH (m) 50 75 MAX. HEIGHT DIFFERENCE (m) 30 30 CHARGE R410A** (kg) 3.5 5.5 PIPE SIZE Liquid 10 10 ø (mm) Gas 16 16 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 8.0 12.3 Heating 9.7 13.9 CIRCUIT BREAKER (A) 25 32 ** LOW NOISE mode ** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units RP can be connected with Mr. Slim R407C outdoor units. 67

Mr. Slim Power Inverter PEAD Cooling / Heating Above-Ceiling Concealed Ducted Systems NEW! Wired remote control with 24h-timer Standard long-life filter Installation height only 325 mm Simple installation with easy access drain and refrigerant piping connections Factory charged with R410A Rotary and scroll compressors Multi Split simultaneous operation possible, page 72 Accessories: Drain pump Fan motor (external static pressure 130 Pa) For detailed descriptions please view on page 70 and the following 68

POWER INVERTER PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATING INDOOR UNIT PEAD-RP3EA PEAD-RP4EA PEAD-RP5EA PEAD-RP6EA CAPACITY COOLING (Min. - Nominal - Max.) kw 3.3-7.1-8.1 5.0-10.0-11.2 6.0-12.5-14.0 6.2-14.0-15.3 CAPACITY HEATING (Min. - Nominal - Max.) kw 3.5-8.0-10.2 5.6-11.2-14.0 6.0-14.0-16.0 6.2-16.0-18.0 COP Cooling/Heating 3.30/3.42 3.25/3.22 3.39/3.41 2.85/3.36 AIRFLOW (m 3 /h) Low 1200 1620 2010 2190 High 1500 2040 2520 2760 EXTERNAL STATIC PRESSURE (Pa) 70(130**) 70(130**) 70(130**) 70(130**) NOISE db(a) Low 37(40) 41(42) 44(46) 46(47) High 41(45) 46(48) 50(52) 51(53) WEIGHT (kg) 44 62 65 70 DIMENSIONS (mm) Width 1175 1415 1415 1715 Depth 740 740 740 740 Height 325 325 325 325 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 1.6 2.5 2.6 2.7 Heating 1.6 2.5 2.6 2.7 OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHA POWER Cooling 2.15 3.08 3.69 4.91 CONSUMPTION (kw) Heating 2.34 3.48 4.11 4.76 AIRFLOW (m 3 /h) 3300 6000 6000 6000 NOISE db(a) 44*/47 46*/49 47*/50 48*/50 WEIGHT (kg) 75 121 121 121 DIMENSIONS (mm) Width 950 950 950 950 Depth 360 360 360 360 Height 943 1350 1350 1350 MAX. PIPE LENGTH (m) 50 75 75 75 MAX. HEIGHT DIFFERENCE (m) 30 30 30 30 CHARGE R410A*** (kg) 3.5 5.5 5.5 5.5 PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 16 16 16 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 RUNNING CURRENT (A) Cooling 8.0 12.3 15.8 20.4 Heating 9.7 13.9 17.5 20.7 CIRCUIT BREAKER (A) 25 32 32 40 *** LOW NOISE mode *** Fan motor optional 130 Pa *** Factory charged to 30 m pipe length, please also view page 73 The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber. Indoor units "RP" can be connected with Mr. Slim R407C outdoor units. 69

Mr. Slim R407C/R410A-Series Accessories Accessories Indoor / Outdoor units PART.NO. DESCRIPTION PLA/PLH PAC-SEO6 WP-E PAC-SEO1 AS-E PAC-SE21 TM-E PAC-SE13 KF-E PAC-SE60 AS-E PAC-SG03 TM-E PAC-SG01 KF-E 4-WAY-IN-CEILING CASSETTE SYSTEMS Wide panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Space panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH Multi-function casement for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH High efficiency filter for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH (PAC-SE21 TM-E needed) Space panel for PLA-P 4/5/6 AA, PLH-P 4/5/6 AAH Multi-function casement for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH High efficiency filter for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH (PAC-SG03 TM-E needed) PCA/PCH PAC-SE85 DMA-E PAC-SE86 DMA-E PAC-SE80 KF-E PAC-SE81 KF-E PAC-SE82 KF-E PAC-SL99A-E CEILING SUSPENDED SYSTEMS Drain pump for PCA-P 2/2.5/3 GA, PCH-P2/2.5/3 GAH Drain pump for PCA-P 4/5/6 GA, PCH-P4/5/6 GAH High efficiency filter for PCA-P2 GA, PCH-P2 GAH High efficiency filter for PCA-P2.5/3/4 GA, PCH-P2.5/3/4 GAH High efficiency filter for PCA-P5/6 GA, PCH-P5/6 GAH Infrared remote control for PCA-P/PCH-P PCA PAC-SG38KF-E CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS Special high efficiency oil filter, 12 pieces PKA/PKH PAC-SE88 DM-E PAR-20MAAT-E WALL-MOUNTED SYSTEMS Drain pump PKA-P/PKH-P Wired remote control for PKH-P/PKA-P PEAD/PEHD PAC-KE03 DM-F PAC-SK005 MT-F PAC-SK004 MT-F PAC-SK003 MT-F CEILING CONCEALED SYSTEMS Drain pump for PEAD-P/PEHD-P Fan motor 130 Pa pressure for PEAD-P3 EA/PEHD-P3 EAH Fan motor 130 Pa pressure for PEAD-P4 EA/PEHD-P4 EAH Fan motor 130 Pa pressure for PEAD-P5/6 EA/PEHD-P5/6 EAH PU/PUH OUTDOOR UNITS PAC-SF37 DS-E Drain socket for Mr. Slim outdoor units P1.6 P6 PAC-SF08 SG-E Air outlet guide for Mr. Slim outdoor units P1.6 P6 (for P4/5/6 2x PAC-SF08 SG-E) PAC-SF16 DP-E Drain pan PU(H)-P 1.6/4 PAC-SF17 DP-E Drain pan PU(H)-P 5/6 PAC-SF09 AG Airflow panel for cooling to -15 C for P1.6 P6 (for P4/5/6 2x PAC-SF09 AG) PUHZ PAC-SG61DS-E PAC-SG59SG-E PAC-SG64DP-E OUTDOOR UNITS Drain socket for Mr. Slim Power Inverter outdoor units RP3-RP6 Air outlet guide for outdoor units RP3-RP6. RP4/5/6 require two PAC-SG59SG-E Drain pan for PUHZ-RP3/4/5/6 VHA 70

Control Accessories Mr. Slim R407C/R410A-Series Accessories PART.NO. PAC-SE41 TS-E PAC-SF48 MA-E PAC-SF40 RM-E PAC-SE55 RA-E CMS-MNF-B LMAP02-E PAC-YT32PTA PAC-SF50MA PAC-SC50KUA PAC-SK52ST DESCRIPTION External Temperature Sensor A/M Net-Converter Operation remote controller board Remote on/off Maintenance Tool, to use with PAC-SF48 MA-E and PAC-SC34 KUA LonWorks -Interface, to use with PAC-SF48 MA-E and PAC-SC50 KUA LCD weekly set back program timer operation only with wired remote control models A/M Net-Converter for Mr. Slim Inverter PUHZ R410 A Power Supply Service-Display for outdoor units P1-P6 and RP3/4/5/6 Further information: Planning handbook Mr. Slim Series 71

Accessories for Multi Split Systems*/Distributors: Twin, triple, quadruple configuration of Mr. Slim indoor units with single outdoor units possible. Ideally suited to open plan areas in small- to medium-sized offices or shops. Mr. Slim R407C: Combinations: INDOOR UNITS PLA-P/PLH-P1.6/2/2.5/3/4/5 PSA-P/PSH-P3/4/5 PCA-P/PCH-P2/2.5/3/4/5 PEAD-P/PEHD-P1.6/2/2.5/3/4/5 PKA-P/PKH-P1.6/2/2.5/3/4 PMH-P1.6/2 OUTDOOR UNITS COMIBINATION Twin 50:50 Twin 50:50 Triple 33:33:33 Triple 25:25:50 Triple 20:40:40 Quadruple 25:25:25:25 PU(H)-P3 YGAA 1.6 + 1.6 PU(H)-P4 YGAA 2 + 2 PU(H)-P5 YGAA 2.5 +2.5 PU(H)-P6 YGAA 3 + 3 2 + 2 + 2 1.6 + 1.6 + 3 PUH-P8 MYA 4 + 4 2.5 + 2.5 + 2.5 2 + 2 + 4 1.6 + 3 + 3 2 + 2 + 2 + 2 PUH-P10 MYA 5 + 5 3 + 3 + 3 2.5 + 2.5 + 5 2 + 4 + 4 2.5 + 2.5 + 2.5 + 2.5 DISTRIBUTOR SDD-50 DA-E SDD-50WSA-E SDT-111 SA-E SDT-112 SA-E SDT-122 SA-E SDT-1111 SA-E Mr. Slim R410A: Combinations: INDOOR UNITS** PLA-RP1.6/2/2.5/3 PKA-RP1.6/2/2.5/3 PEAD-RP1.6/2/2.5/3 OUTDOOR UNITS COMBINATION Twin 50:50 Triple 33:33:33 PUHZ-RP3VHA 1.6 + 1.6** PUHZ-RP4VHA 2 + 2** PUHZ-RP5VHA 2.5 +2.5** PUHZ-RP6VHA 3 + 3 2 + 2 + 2** DISTRIBUTOR SDD-50SR-E SDT-111R-E ** Attention: Only indoor units of same type can be installed. In Multi-Split-Mode all indoor units have to be installed in the same room because of temperature sense in the master unit. ** RP1.6/2/2.5 available from August 2004 72

Mr. Slim-Series Technical Data Refrigerants R407C/R410A Charge R407C Charge concerning single operation, optional charges for simultaneous operation as in the planning guide described. Outdoor units P1-2.5: Factory charged to 20 m pipe length Outdoor units P3-P6: Factory charged to 30 m pipe length Outdoor units P8 and P10: Factory charged 6 kg and 6.5 kg R407C. Please view in the table above pipe length and charging data Correction Factor R407C EFFICIENCY CLASS OUTDOOR UNITS CORRECTION FACTOR CAPACITY OF COOLING/HEATING CHARGING (ONE WAY) IN kg 10 m 20 m 30 m 40 m 50 m PUH-P1 VGAA 1.7 1.7 1.8 PU(H)-P1.6 YGAA 2.5 2.5 2.6 3.0 PU(H)-P2 YGAA 2.6 2.6 3.1 3.7 PU(H)-P2.5 YGAA 3.1 3.1 3.3 3.9 4.5 PU(H)-P3 YGAA 3.3 3.9 4.5 PU(H)-P4 YGAA 4.0 4.7 5.4 PU(H)-P5 YGAA 4.6 5.3 6.0 PU(H)-P6 YGAA 4.9 5.6 6.3 PUH-P8 MYA 7.0 7.5 8.0 8.5 9.0 PUH-P10 MYA 7.5 8.0 8.5 9.0 9.5 PIPE LENGTH (ONE WAY)/M 5 10 15 20 25 30 35 40 45 50 P1 1.00/1.00 0.992/0.997 0.983/0.996 0.978/0.994 0.966/0.991 0.959/0.989 / / / / P1.6 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 / / P2 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 / / P2.5 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978 P3 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P4 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978 P5 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P6 1.00/1.00 0.975/0.998 0.955/0.995 0.935/0.993 0.918/0.990 0.900/0.988 0.884/0.985 0.869/0.983 0.855/0.980 0.840/0.978 P8 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.965/0.995 0.960/0.995 0.940/0.995 0.935/0.995 0.930/0.995 P10 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.960/0.995 0.958/0.995 0.955/0.995 0.950/0.995 0.950/0.995 Charge R410A Outdoor units PUHZ-P3/4/5/6VHA factory charged to 30 m pipe length (one-way), optional charges as in the table. OUTDOOR UNITS CHARGING (ONE WAY) IN kg 10 m 20 m 30 m 40 m 50 m 60 m 75 m PUHZ-RP3VHA 3.1 3.3 3.5 4.1 4.7 PUHZ-RP4VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9 PUHZ-RP5VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9 PUHZ-RP6VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9 Correction Factor R410A EFFICIENCY CLASS CORRECTION FACTOR CAPACITY OF COOLING/HEATING PIPE LENGTH (ONE WAY)/M 5 10 15 20 30 40 50 60 70 75 RP3 1.00/1.00 0.989/0.997 0.978/0.994 0.967/0.991 0.947/0.985 0.930/0.979 0.905/0.973 / / / RP4 1.00/1.00 0.985/0.997 0.971/0.994 0.958/0.991 0.931/0.985 0.908/0.979 0.887/0.973 0.865/0.967 0.847/0.961 0.838/0.958 RP5 1.00/1.00 0.982/0.997 0.963/0.994 0.9470.991 0.914/0.985 0.885/0.979 0.858/0.973 0.834/0.967 0.812/0.961 0.802/0.958 RP6 1.00/1.00 0.976/0.997 0.953/0.994 0.932/0.991 0.893/0.985 0.858/0.979 0.828/0.973 0.800/0.967 0.776/0.961 0.764/0.958 73

City Multi-Series Y and R2 For large applications such as office blocks, hotels and large retail stores, City Multi variable refrigerant flow (VRF) multi-split systems offer significant advantages over centralised plant systems. A certain times of the year, many buildings can require cooling in some areas and heating in others even in adjacent rooms. The outstanding City Multi R2 and WR2 systems meet this requirement by distributing surplus heat from cooling operations to rooms where it is needed. This can result in energy savings of up to 20% over conventional systems. The water-cooled WR-system is adaptable specially to high-rise buildings. 74

Advantages of the City Multi-Series City Multi Super Y-Series manages up to 32 indoor units in a single refrigerant circle Simultaneous cooling and heating with incomparable 2-pipe-system By distributing surplus heat from cooling operations to rooms where it is needed, the result can be 15% - 20% energy savings over conventional systems Automatic switch of operating mode (heating/cooling), the room temperature stays constant Many indoor units, capacity-steps and installation possibilities to select Inverter-driven outdoor compressor units with very low start currents Remote control of individual indoor units, to centralised systems, right up to full interface with industry standard Building Management Systems CITY MULTI Y-Series City Multi Y-Series utilise 2-pipe technology for cooling and heating mode. By manual switch the most comfortable air conditions can be choosen. The system is very versatile, it is possible to install up to 32 different indoor units to a single refrigerant circle. The capacity of all installed indoor units can be 50% up to 130%. CITY MULTI R2-Series The City Multi range has been re-engineered to use R407C ozone-friendly refrigerant without performance loss. Modern buildings with a reduced exchange of air, technical equipment like PCs, printer etc. which warm up the air require efficient air conditioning with simultaneous cooling and heating. The "Fuzzy-logic makes individual air conditioning with max. 24 indoor units possible. Inverter-driven outdoor compressor units with very low start currents save energy. Distributing surplus heat from cooling operations to rooms where it is needed is another way to save energy. Control options to suit every kind of application City Multi systems offer an extremely wide choice of control solutions, from remote control of individual indoor units, to centralised systems and computer-aided systems which allow to control up to 2,000 units. Right up to full interface with industry standard Building Management Systems. Operating range of City Multi Cooling: indoor 15 24 C (WB)/outdoor -5 43 C (DB) (water temperature for WR2: 10 C 45 C) Heating (Y-Series): indoor 15 27 C (DB)/ outdoor -15 15.5 C (WB) Heating (R2-Series): indoor 15 27 C (DB)/ outdoor -15 15.5 C (WB) (water temperature for WR2: 10 C 45 C) Features of City Multi.................................................... 78 City Multi Y-series - Outdoors units........................................ 80 City Multi R2 series - Outdoors units and BC-controllers...................... 82 PMFY/PLFY - Ceiling cassettes........................................... 84 PCFY/PKFY - Suspended indoor units...................................... 85 PEFY - Concealed ducted indoor units..................................... 86 PFFY - Floor standing indoor units......................................... 87 City Multi - Control accessoires........................................... 88 City Multi - Accessoires.................................................. 93 75

City Multi Systems: Economic, efficient and high-quality CITY MULTI Y-SERIES Switching between Heating and Cooling Flexible and Powerful Response from Compact Dimensions Flexibility is the motto with the City Multi Y-Series. A wide line-up of indoor units in combination with a flexible piping system can conform to any layout. From 8 to 32 indoor units, depending on capacity, can be connected to Y-Standard, BIG Y and SUPER Y outdoor units. All indoor units connected to only one refrigerant circuit. This enables easy air conditioning of areas requiring individual control. In common with the R2, the City Multi Y-Series can be easily operated through a central controller. Header Branch Y-Series Outdoor unit Indoor unit Indoor unit 76

CITY MULTI R2-SERIES Simultaneous Cooling and Heating excellent air conditioning under the aspect of economy. The R2-System means that simultaneous cooling and heating is possible. With the BC Controller connecting from 4 to 24 indoor units to one outdoor unit using only two pipes and energy-saving heat recovery operation, economy and efficiency are guaranteed. Smooth auto-switching (heating/cooling) based on set temperature realises easier operation and more comfortable environment in auto-mode. The WR2-System uses the same technical bases like the well-known R2-System. But the WR2-Series is the world s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. WR2-System is specially for high-rise buildings. R2-Series Outdoor unit WR2-Series Outdoor unit Water piping Conference room (cooling) BC Controller Connection Office (cooling) Two-Pipe system Conference room (heating) OA room (cooling) Office (heating) World-wide the only system for simultaneous cooling and heating with 2 pipes. 77

Mitsubishi Electric FEATURES of CITY MULTI Flexible and Adaptable The variety provided by 19 outdoor models and 65 indoor models (9 different types) increase design flexibility. The Y-Series: Cooling or heating mode, a maximum of 32 indoor units connectable with one refrigerant circuit. The R2-Series: Simultaneous heating/cooling with up to 24 indoor units and heat recovery by BC-controller. WR2-Series: World s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units. SERIES Outdoor Cooling Heating No. of Total Capacity of unit capacity capacity Connect capacity connectable (kw) (kw) indoor units indoor units indoor models* Y-SERIES PUMY-P125 YMA 14.0 16,0 1-8 50-130% 20-125 PUY-P200 YEM-A 22.4 1-13 PUY-P250 YEM-A 28.0 1-16 PUY-P315 YEM-A 35.5 1-16 50-130 % 20-250 PUHY-P200 YEM-A 22.4 25.0 1-13 PUHY-P250 YEM-A 28.0 31.5 1-16 PUHY-P315 YEM-A 35.5 40,0 1-16 R407C BIG Y- SERIES SUPER Y- SERIES PUHY-P400 YMF-C 45.0 50.0 1-20 PUHY-P500 YMF-C 56.0 63.0 1-20 PUHY-P400 YMF-C + PUHN-P200 YMF-C 67.4 75.0 2-32 PUHY-P400 YMF-C + PUHN-P250 YMF-C 73.0 81.5 2-32 PUHY-P500 YMF-C + PUHN-P200 YMF-C 78.4 88.0 2-32 PUHY-P500 YMF-C + PUHN-P250 YMF-C 84.0 94.5 2-32 50-130% 25-250 50-130% 20-250 R2-SERIES BIG R2- SERIES WR2- SERIES PURY-P200 YEM-A 22.4 25.0 1-15 PURY-P250 YEM-A 28.0 31.5 1-16 PURY-P400 YMF-C 45.0 50.0 2-24 PURY-P500 YMF-C 56.0 63.0 2-24 PQRY-P200 YMF-C 22.4 25.0 1-15 PQRY-P250 YMF-C 28.0 31.5 1-16 50-150% 20-250 50-150% 20-250 50-150% 20-250 * Indoor units available: Type 20 (2.2 kw) up to type 250 (28.0 kw) 78

Indoor units - Overview All City Multi indoor units are compatible to Y-Series, R2- and WR2-Series. Capacity Capacity code P 20 P 25 P 32 P 40 P 50 P 63 P 71 P 80 P 100 P 125 P 140 P 200 P 250 Cooling capacity (kw) 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0 Type Heating capacity (kw) 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5 Ceiling Cassette Type (1-way airflow) PMFY-VBM-A Ceiling Cassette Type (2-way airflow) PLFY-VLMD-A/-B Ceiling Cassette Type (4-way airflow) PLFY-VKM-A/VAM-A B-model A-model Ceiling Concealed (horizontal airflow) PEFY-VML-A/VMH-A Ceiling Concealed (variable airflow) PEFY-VMM-A L-model* H-model* Ceiling Suspended Type PCFY-VGM-A Wall Mounted Type PKFY-VAM-A Wall Mounted Type PKFY-VGM-A Floor Standing Exposed Type PFFY-VLEM-A Floor Standing Concealed Type PFFY-VLRM-A * L-model: low stat. pressure, H-model: high stat. pressure 79

Outdoor units - Technical data City Multi Y-Series, Cooling or Heating City Multi Y-Series: PUMY-P125 YMA OUTDOOR UNIT PUMY-P125 YMA MODEL REFERENCE PUMY-P125 YMA CAPACITY (kw) Cooling 14.0 Heating 16.0 AIRFLOW (m 3 /h) 5400 NOISE* db(a) 54 WEIGHT (kg) 127 DIMENSIONS (mm) Width 1020 Depth 350 Height* 1280 MAX. PIPE LENGTH** (m) 100 MAX. HEIGHT DIFFERENCE (m) 30 CHARGE R407C*** (kg) 8.5 PIPE SIZE ø (mm) liquid 10 gas 18 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling 5.95 Heating 5.58 STARTING CURRENT (A) 8 RUNNING CURRENT (A) 9.1 INDOOR UNITS TO INSTALL (pcs.) 1-8 / 20-125 City Multi Standard Y: PU(H)Y-P 200/250/315 YEM-A STANDARD Y OUTDOOR UNIT COOLING ONLY COOLING/HEATING MODEL REFERENCE PUY- PUY- PUY- PUHY- PUHY- PUHY- P200YEM-A P250YEM-A P315YEM-A P200YEM-A P250YEM-A P315YEM-A CAPACITY (kw) Cooling 22.4 28.0 35.5 22.4 28.0 35.5 Heating 25.0 31.5 40.0 AIRFLOW (m 3 /h) 12000 12000 12000 12000 12000 12000 NOISE* db(a) 56 57 60 56 57 60 WEIGHT (kg) 225 225 240 225 225 240 DIMENSIONS (mm) Width 990 990 990 990 990 990 Depth 840 840 840 840 840 840 Height* 1755 1755 1755 1755 1755 1755 MAX. PIPE LENGTH** (m) 240 240 240 240 240 240 MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 50 50 CHARGE R407C (kg) 7 7 9 7 7 9 PIPE SIZE ø (mm) liquid 12 12 12 12 12 12 gas 28 28 35 28 28 35 380-415V, 50Hz, 3 380-415V, 50Hz, 3 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling 6.32 8.54 12.3 6.32 8.54 12.3 Heating 6.80 8.95 12.49 STARTING CURRENT (A) 8 8 8 8 8 8 RUNNING CURRENT (A) 10.6 14.4 20.3 11.4 15.1 20.6 INDOOR UNITS TO INSTALL (Number/Type) 1-13/20-250 1-16/20-250 1-16/20-250 1-13/20-250 1-16/20-250 1-16/20-250 *** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. *** one-way *** Factory charged to 50 m pipe length (one-way) 80

City Multi BIG Y and Super Y-Series BIG Y OUTDOOR UNITS MODEL REFERENCE PUHY-P400YMF-C PUHY-P500YMF-C CAPACITY (kw) Cooling 45.0 56.0 Heating 50.0 63.0 AIRFLOW (m 3 /h) 22200 22200 NOISE* db(a) 60 60 WEIGHT (kg) 440 475 DIMENSIONS (mm) Width 1990 1990 Depth 840 840 Height 1715 1715 MAX. PIPE LENGTH** (m) 220 220 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C (kg) 16 22 PIPE SIZE ø (mm) liquid 16 16 gas 35 35 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling 16.3 20.5 Heating 15.2 19.0 INDOOR UNITS TO INSTALL (pcs.) 1-20/25-250 City Multi Big Y: PUHY-P400/500 YMF-C PUHN UNITS MODEL REFERENCE PUHN-P200YMF-C PUHN-P250YMF-C CAPACITY (kw) Cooling 22.4 28.0 Heating 25.0 31.5 AIRFLOW (m 3 /h) 11100 11100 NOISE* db(a) 61 62 WEIGHT (kg) 240 255 DIMENSIONS (mm) Width 990 990 Depth 840 840 Height 1715 1715 MAX. PIPE LENGTH** (m) 220 220 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C (kg) 6.5 8.5 PIPE SIZE ø (mm) liquid 12 12 gas 28 28 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling Depending of Combination Heating City Multi Super Y SUPER Y: COMBINATION OF BIG Y AND PUHN MODEL REFERENCE Cooling capacity (kw) Heating capacity (kw) Noise level Indoor units to install db(a) (pcs.) Super Y PUHY-P400YMF-C + PUHN-P200YMF-C 67.4 75.0 61.5 2-32/20-250 Super Y PUHY-P400YMF-C + PUHN-P250YMF-C 73.0 81.5 62.0 2-32/20-250 Super Y PUHY-P500YMF-C + PUHN-P200YMF-C 78.4 88.0 61.5 2-32/20-250 Super Y PUHY-P500YMF-C + PUHN-P250YMF-C 84.0 94.5 62.0 2-32/20-250 When adding 20 or more indoor units to one system transmission booster PAC-SF46EPA is needed. For connecting PUHN use SUPER Y Kit CMC-30A. ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way 81

Outdoor units - Technical data City Multi R2-Series City Multi R2: PURY-P 200/250 YEM-A Cooling + Heating simultaneous with heat recovery R2-OUTDOOR UNITS MODEL REFERENCE PURY- P200YEM-A PURY- P250YEM-A CAPACITY (kw) Cooling 22.4 28.0 Heating 25.0 31.5 AIRFLOW (m 3 /h) 12000 12000 NOISE* db(a) 56 57 WEIGHT (kg) 238 238 DIMENSIONS (mm) Width 990 990 Depth 840 840 Height 1755 1755 MAX. PIPE LENGTH** (m) 240 240 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C (kg) 10.5 10.5 PIPE SIZE ø (mm) liquid 18 18 gas 28 28 380-415V, 50Hz, 3 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling 6.32 8.54 Heating 6.80 8.95 STARTING CURRENT (A) 8 8 RUNNING CURRENT (A) 11.4 15.1 INDOOR UNITS TO INSTALL (pcs.) 1-15/20-250 1-16/20-250 City Multi WR2: PQRY-P200/250 YMF-C Note: 1) Cooling/heating capacity indicates the maximum value at operation under the following conditions: Cooling/outdoor: 35 C DB/24 C WB Watertemperature WR2 30 C Heating/outdoor: 7 C DB/6 C WB Watertemperature WR2 20 C 2) The ambient temperature of heat source units has to be kept below 40 C DB. The ambient relative humidity of heat source units has to be kept below 80% WR2-SERIES WITH WATER COOLED HEAT EXCHANGER (ONLY FOR INDOOR USE) MODEL REFERENCE PQRY-P200YMF-C PQRY-P250YMF-C CAPACITY (kw) Cooling 22.4 28.0 Heating 25.0 31.5 COOLING WATER FLOW RATE (m 3 /h) 3.9 4.9 PRESSURE DROP (k Pa) 8 10 MAX. PIPING LENGTH** (m) 220 220 REFRIGERANT CIRCUIT MAX. HIGH DIFFERENCE (m) 50 50 REFRIGERANT CIRCUIT CHARGE R407C (kg) 7.5 8.5 NOISE* db(a) 51 52 WEIGHT (kg) 270 280 DIMENSIONS (mm) Width 1150 1150 Depth 500 500 Height 1670 1670 380-415V, 50Hz, 3 INPUT POWER (kw) Cooling 7.6 9.7 Heating 7.4 9.4 STARTING CURRENT (A) 12 12 RUNNING CURRENT (A) 12.1 15.5 PIPE SIZE ø (mm) liquid 18 18 GAS 28 28 OPERATING TEMP. RANGE COOLING INDOOR 15ºC 24ºC (WB) / watertemp.10º C 45º C HEATING INDOOR 15ºC 27ºC (DB) / watertemp.10º C 45º C INDOOR UNITS NO./TYPE 1-15/20-250 1-16/20-250 BC-Controller required for R2/WR2 ** Noise level measured at a position of 1m in front of the unit. ** one-way 82 BC-CONTROLLER FOR R2/WR2-SERIES MODEL REFERENCE CMB- CMB- CMB- CMB- CMB- CMB- CMB- P104V-F P105V-F P106V-F P108V-F P1010V-F P1013V-F P1016V-F NUMBER OF CONNECTIONS 4 5 6 8 10 13 16 PIPE SIZE EXT., ø (mm) liquid 18 18 18 18 18 18 18 gas 28 28 28 28 28 28 28 BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) liquid 10 10 10 10 10 10 10 gas 16 16 16 16 16 16 16 Indoor unit at BC-Controller WEIGHT (kg) 24 27 29 34 39 47 54 DIMENSIONS (mm) Width 648 648 648 648 648 1098 1098 Depth 432 432 432 432 432 432 432 Height 284 284 284 284 284 284 284, (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.07 0.08 0.09 0.13 0.16 0.2 0.25 RUNNING CURRENT (A) 0.3 0.36 0.43 0.56 0.69 0.89 1.08

BIG R2-OUTDOOR UNITS MODEL REFERENCE PURY-P400YMF-C PURY-P500YMF-C CAPACITY (kw) Cooling 45,0 56,0 Heating 50.0 63,0 AIRFLOW (m 3 /h) 22200 22200 NOISE* db(a) 60 60 WEIGHT (kg) 470 500 DIMENSIONS (mm) Width 1990 1990 Depth 840 840 Height 1715 1715 MAX PIPE LENGTH** (m) 250 250 MAX HIGH DIFFERENCE (m) 50 50 CHARGE R407C (kg) 20 22 PIPE SIZE ø (mm) liquid 28 28 gas 35 35 (V, Freq.,Phase) 380-415V, 50Hz, 3 INPUT POWER (Cooling) 16,3 20.5 (Heating) 15.2 19.0 INDOOR UNITS TO INSTALL No./Type 2-24/20-250 ** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way City Multi Big R2: PURY-P400/500 YMF-C MASTER-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE CMB- CMB- CMB- CMB- P108V-FA P1010V-FA P1013V-FA P1016V-FA NUMBER OF CONNECTIONS 8 10 13 16 PIPE SIZE EXT., ø (mm) liquid 28 28 28 28 gas 35 35 35 35 BC-Controller at outdoor unit PIPE SIZE EXT. ø (mm) liquid 10 10 10 10 gas 16 16 16 16 Indoor unit at BC-Controller PIPE SIZE EXT. ø (mm) liquid 12 12 12 12 gas 18 18 18 18 Master-Controller at Slave-Controller 28 28 28 28 WEIGHT (kg) 44 49 57 64 DIMENSIONS (mm) Width 1110 1110 1110 1110 Depth 520 520 520 520 Height 289 289 289 289, (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.14 0.17 0.23 0.26 RUNNING CURRENT (A) 0.58 0.7 0.89 1.08 Master- Controller SLAVE-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE CMB- P108V-FB NUMBER OF CONNECTIONS 8 PIPE SIZE EXT., ø (mm) liquid 12 gas 18 Slave Controller at Master Controller 28 PIPE SIZE EXT. ø (mm) liquid 10 gas 16 Indoor unit at Slave Controller WEIGHT (kg) 32 DIMENSIONS (mm) Width 648 Depth 432 Height 284, (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.128 RUNNING CURRENT (A) 0.53 Slave- Controller Note: The Slave BC-Controller can only use in combination with the Master Controller 83

Indoor Units - Technical Data PMFY 1-WAY IN-CEILING CASSETTES MODEL REFERENCE PMFY-P20VBM-A PMFY-P25VBM-A PMFY-P32VBM-A PMFY-P40VBM-A GRILLE MODEL PMP-40 BM PMP-40 BM PMP-40 BM PMP-40 BM CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 Heating 2.5 3.2 4.0 5.0 AIRFLOW (m3/h) Low 390 438 438 462 Middle 1 432 480 480 522 Middle 2 480 512 512 582 High 522 558 558 642 NOISE* (Low/High) db(a) 27/35 32/37 32/37 33/39 WEIGHT / incl. Grille (kg) 14 (17) 14 (17) 14 (17) 14 (17) DIMENSIONS (mm) (Grille) Width 854 (1000) 854 (1000) 854 (1000) 854 (1000) Depth 395 (470) 395 (470) 395 (470) 395 (470) Height** 230 (30) 230 (30) 230 (30) 230 (30) PIPE SIZE ø (mm) liquid 6 6 6 6 gas 12 12 12 12 (V, Freq.,Phase) 220 240 V, 50 Hz, 1 INPUT POWER (kw) 0.042 0.044 0.044 0.054 RUNNING CURRENT (A) 0.2 0.21 0.21 0.26 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 2-WAY IN-CEILING CASSETTES MODEL REFERENCE PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- P20VLMD-B P25VLMD-B P32VLMD-B P40VLMD-B P50VLMD-B P63VLMD-B P80VLMD-A P100VLMD-A P125VLMD-A GRILLE MODEL CMP-40 CMP-40 CMP-40 CMP-40 CMP-63 CMP-63 CMP-63 CMP-125 CMP-125 VLW-B VLW-B VLW-B VLW-B VLW-B VLW-B LW-F LW-F LW-F CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 Heating 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0 AIRFLOW (m3/h) Low 390 390 390 420 540 600 900 1260 1440 Middle 1 480 480 480 510 660 780 1020 1380 1620 Middle 2 1140 1560 1800 High 570 570 570 630 750 930 1260 1740 1980 NOISE* (Low/High) db(a) 27 / 33 27 / 33 27 / 33 29 / 36 31 / 37 32 / 39 36 / 43 37 / 43 40 / 46 WEIGHT / incl. Grille (kg) 23 (29.5) 23 (29.5) 24 (30.5) 24 (30.5) 27 (34.5) 28 (35.5) 41 (51) 56 (67.5) 56 (67.5) DIMENSIONS (mm) Width 776 (1080) 776 (1080) 776 (1080) 776 (1080) 946 (1250) 946 (1250) 1358 (1650) 1708 (2000) 1708 (2000) (Grille) Depth 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 606 (670) 606 (670) 606 (670) Height** 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (8) 338 (8) 338 (8) PIPE SIZE ø (mm) liquid 6 6 6 6 6 10 10 10 10 gas 12 12 12 12 12 16 16 18 18 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.075 0.075 0.075 0.085 0.086 0.105 0.23 0.25 0.28 RUNNING CURRENT (A) 0.37 0.37 0.37 0.42 0.43 0.51 1.1 1.2 1.35 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height PLFY 4-WAY IN-CEILING CASSETTES PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- MODEL REFERENCE P32VKM-A P40VKM-A P50VKM-A P63VKM-A P80VAM-A P100VAM-A P125VAM-A GRILLE MODEL PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-6AA PLP-6AA PLP-6AA CAPACITY (kw) Cooling 3.6 4.5 5.6 7.1 9.0 11.2 14.0 Heating 4.0 5.0 6.3 8.0 10.0 12.5 16.0 AIRFLOW (m3/h) Low 780 780 780 840 960 1200 1320 Middle 1 840 840 840 900 1080 1380 1500 Middle 2 870 870 900 960 1200 1560 1680 High 900 900 960 1020 1320 1680 1800 NOISE* (Low/High) db(a) 31 / 35 31 / 35 32 / 37 35 / 39 30 / 37 33 / 41 35 / 43 WEIGHT / incl. Grille (kg) 19 (22.7) 19 (22.7) 19 (22.7) 20 (23.7) 24 (29) 30 (35) 30 (35) DIMENSIONS Width 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950) (Grille) Depth 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950) Height** 298 (30) 298 (30) 298 (30) 298 (30) 258 (30) 298 (30) 298 (30) PIPE SIZE ø (mm) liquid 6 6 6 10 10 10 10 gas 12 12 16 16 16 18 18 (V, Freq.,Phase) 220-240V, 50Hz,1 INPUT POWER (kw) 0.13 0.13 0.14 0.15 0.18 0.3 0.34 RUNNING CURRENT (A) 0.6 0.6 0.64 0.68 0.86 1.43 1.64 * The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 84

PCFY SUSPENDED INDOOR UNITS MODEL REFERENCE PCFY- P40VGM-A PCFY- P63VGM-A PCFY- P100VGM-A PCFY- P125VGM-A CAPACITY (kw) Cooling 4.5 7.1 11.2 14.0 Heating 5.0 8.0 12.5 16.0 AIRFLOW (m3/h) Low 480 720 1080 1560 Middle 1 600 840 1200 1680 Middle 2 660 960 1380 1920 High 720 1080 1500 2100 NOISE* db(a) 29 / 38 32 / 39 36 / 43 37 / 44 (Low/High) WEIGHT (kg) 27 34 37 43 DIMENSIONS (mm) Width 1000 1310 1310 1620 Depth 680 680 680 680 Hight 210 210 270 270 PIPE SIZE ø (mm) liquid 6 10 10 10 gas 12 16 18 18 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.10 0.13 0.16 0.24 RUNNING CURRENT (A) 0.46 0.6 0.73 1.1 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber PKFY WALL MOUNTED INDOOR UNITS MODEL REFERENCE PKFY-P20VAM-A PKFY-P25VAM-A PKFY-P32VGM-A PKFY-P40VGM-A PKFY-P50VGM-A CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 Heating 2.5 3.2 4.0 5.0 6.3 AIRFLOW (m3/h) Low 294 294 480 480 540 Middle 1 312 312 570 570 600 Middle 2 336 336 630 630 660 High 354 354 690 690 720 NOISE* db(a) 32 / 36 32 / 36 33 / 41 33 / 41 34 / 43 (Low/High) WEIGHT (kg) 8.5 8.5 16 16 16 DIMENSIONS (mm) Width 815 815 990 990 990 Depth 158 158 235 235 235 Height 295 295 340 340 340 PIPE SIZE ø (mm) liquid 6 6 6 6 10 gas 12 12 12 12 16 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.04 0.04 0.07 0.07 0.07 RUNNING CURRENT (A) 0.2 0.2 0.32 0.32 0.32 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber 85

Indoor Units - Technical Data PEFY CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, VML WITH FILTER AS STANDARD MODEL REFERENCE PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY- P20VML-A P25VML-A P32VML-A P40VMH-A P50VMH-A P63VMH-A P71 VMH-A CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 8.0 Heating 2.5 3.2 4.0 5.0 6.3 8.0 9.0 AIRFLOW (m3/h) Low 324 324 360 600 600 810 930 Middle 390 390 450 High 474 474 570 840 840 1140 1320 EXT. STATIC PRESSURE (Pa) 5 5 5 50 / 100 /150 / 200 NOISE* (Low/High) db(a) 29/36 29/36 30/40 27/34 27/34 32/38 32/39 WEIGHT (kg) 18 18 18 44 44 45 50 DIMENSIONS (mm) Width 720 720 720 750 750 750 1000 Depth 550 550 550 900 900 900 900 Hight 225 225 225 380 380 380 380 PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 10 gas 12 12 12 12 16 16 16 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.05 0.05 0.07 0.19 0.19 0.24 0.26 RUNNING CURRENT (A) 0.24 0.24 0.32 0.88 0.88 1.12 1.20 PEFY CEILING CONCEALED DUCTED (REAR SUCTION) INDOOR UNITS MODEL REFERENCE PEFY- P80VMH-A PEFY- P100VMH-A PEFY- P125VMH-A PEFY- P140VMH-A** PEFY- P200VMH-A** PEFY- P250 VMH-A** CAPACITY (kw) Cooling 9.0 11.2 14.0 16.0 22.4 28.0 Heating 10.0 12.5 16.0 18.0 25.0 31.5 AIRFLOW (Low/High) (m3/h) 1080/1500 1590/2280 1590/2280 1680/2400 3480 4320 EXT. STATIC PRESSURE (Pa) 50/100/150/200 100/130/220/260 NOISE* (Low/High) db(a) 35/41 34/42 34/42 34/42 45*** 52*** WEIGHT (kg) 50 70 70 70 100 100 DIMENSIONS (mm) Width 1000 1200 1200 1200 1250 1250 Depth 900 900 900 900 1120 1120 Hight 380 380 380 380 470 470 PIPE SIZE ø (mm) liquid 10 10 10 10 12 12 gas 16 18 18 18 28 28 (V, Freq.,Phase) 220-240V, 50Hz, 1 380-415V, 50Hz, 3 INPUT POWER (kw) (kw) 0.32 0.48 0.48 0.48 0.99 1.23 RUNNING CURRENT (A) 1.47 2.34 2.34 2.35 1.62 2.00 ***The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Refering to projects. Please ask for delivery times. *** at 220 PA PEFY CEILING CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, FILTER AS STANDARD MODEL REFERENCE PEFY- PEFY - PEFY - P20VMM-A P25VMM-A P32VMM-A PEFY - P40VMM-A PEFY - P50VMM-A PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - P63VMM-A P71VMM-A P80VMM-A P100VMM-A P125VMM-A P140VMM-A CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 Heizleistung Heating 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 AIRFLOW(m3/h) Low 360 360 450 600 720 810 870 870 1380 1440 1770 Middle 432 432 540 720 870 972 1080 1080 High 510 510 630 840 1020 1440 1260 1260 1980 2040 2520 EXT. STATIC PRESSURE (Pa) 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 50/130 50/130 50/130 NOISE* (Low/High) db(a) 27 / 32 27 / 32 28 / 35 31 / 37 31 / 38 31 / 38 32 / 39 32 / 39 40 / 44 42 / 45 42 / 45 WEIGHT (kg) 27 27 27 33 33 42 42 42 62 65 70 DIMENSIONS (mm) Width 815 815 815 935 935 1175 1175 1175 1415 1415 1715 Depth 700 700 700 700 700 700 700 700 740 740 740 Hight 295 295 295 295 295 295 295 295 325 325 325 PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 10 10 10 10 10 gas 12 12 12 12 16 16 16 16 18 18 18 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.15 0.15 0.17 0.19 0.2 0.22 0.25 0.17 0.29 0.4 0.42 RUNNING CURRENT (A) 0.73 0.73 0.81 0.92 0.98 1.07 1.15 0.82 1.31 1.9 1.95 *The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 86

PFFY FLOOR STANDING (CONCEALED TYPE) INDOOR UNITS MODEL REFERENCE PFFY- PFFY- PFFY- PFFY- PFFY- PFFY- P20VLRM-A P25VLRM-A P32VLRM-A P40VLRM-A P50VLRM-A P63VLRM-A CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 Heating 2.5 3.2 4.0 5.0 6.3 8.0 AIRFLOW (m3/h) 330/390 330/390 420/540 540/660 720/840 720/930 (Low/High) NOISE* db(a) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43 (Low/High) WEIGHT (kg) 18.5 18.5 20 21 25 27 DIMENSIONS (mm) Width 886 886 1006 1006 1246 1246 Depth 220 220 220 220 220 220 Height 639 639 639 639 639 639 PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 gas 12 12 12 12 16 16 (V, Freq., Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.04 0.04 0.06 0.065 0.085 0.1 RUNNING CURRENT (A) 0.19 0.19 0.29 0.32 0.40 0.46 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber PFFY FLOOR STANDING (CABINET TYPE) INDOOR UNITS MODEL REFERENCE PFFY- PFFY- PFFY- PFFY- PFFY- PFFY- P20VLEM-A P25VLEM-A P32VLEM-A P40VLEM-A P50VLEM-A P63VLEM-A CAPACITY (kw) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 Heizleistung Heating 2.5 3.2 4.0 5.0 6.3 8.0 AIRFLOW (m3/h) 330/390 330/390 420/540 540/660 720/840 720/930 (Low/High) NOISE* db(a) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43 (Low/High) WEIGHT (kg) 23 23 25 26 30 32 DIMENSIONS (mm) Width 1050 1050 1170 1170 1410 1410 Depth 220 220 220 220 220 220 Height 630 630 630 630 630 630 PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 Anschlüsse, außen ø (mm) gas 12 12 12 12 16 16 (V, Freq.,Phase) 220-240V, 50Hz, 1 INPUT POWER (kw) 0.04 0.04 0.06 0.065 0.085 0.1 RUNNING CURRENT (A) 0.19 0.19 0.29 0.32 0.40 0.46 *The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber 87

City Multi System Control Standard Remote Control PAR-20MAA PAR-20 MAA to connect at the indoor unit, building of groups of seperate Databus System possible 1 Indoor unit individual, 1 Group with 16 indoor units possible by two-wire signal lines Easy to read, easy to operate display On/Off Timer Temperature selection in 1 C units Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. PAR-F27 MEA PAR-F27 MEA to connect at the City Multi Databus System, easy to form groups 1 Indoor unit individual / 1 Group with16 indoor units Easy to read, easy to operate display Extensive time function Temperature selection in 1 C units Auto-diagnosis display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. Room thermometer is built into the remote controller. Switching possible to indoor unit room thermometer. Limit temperature setting Operating status readout Exposed type PAC-SE51 CRA PAC-YT51 CRA* To simplify operation of the system, the range of controls has been limited to START/STOP, room temperature and fan speed The only wiring required is cross-over wiring based on two-wire signal lines Room temperature sensors are built-in The indoor unit can be replaced with body thermostats Easy-to-read, easy-to-operate icon display Temperature selection Can operate all types of indoor units Standardized remote controllers for all indoor units 1 indoor unit individual/1 group with 16 indoor units PAC-SE51 CRA Grouping addressing by data bus PAC-YT51 CRA Main grouping by two-wire signal lines *Since this system has no operation mode switching, test operation, self-diagnosis or linked setting functions, it should always be used in conjunction with the PAR-F27MEA or other centralized controller. 88

City Multi System Control Accessories Infrared-, Group- and System Remote Control Timer PAR-FL31MA Infrared-Remote Control PAR-FL31 MA and PAR-FA31 MA (Signal receiver) PAR-FA31MA It can operate in a group system without requiring address settings When operating, it displays LED lamps. When errors occure, the error can be shown by the LED flash count 1 Indoor unit individual/1 group with 16 indoor units by two-wire signal lines Group Remote Control PAC-SC30 GRA PAC-SC30GRA Easy to read, easy to operate display Temperature selection in 1 C units Auto-diagnosis-display A microcomputer constantly monitors operation to keep the units running smoothly. Should problems occure, the temperature setting display changes to an auto-diagnosis display that shows the inspection mode and the unit address alternately. 8 Indoor units individual / Max. 16 Indoor units in 8 groups Programme Timer PAC-YT32 PTA One-week scheduling by remote controller Set-back function Control for PAR-F27 MEA (1 Indoor unit individual / 1 group with 16 indoor units) PAC-YT32 PTA 89

City Multi System Control Accessories Infrared-, Group- and System Remote Control Timer On/Off Remote Controller PAC-YT40 ANRA Up to 50 groups Price competitive solution, up to 50 indoor units PAC-YT40 ANRA System Remote Controller PAC-SF44 SRA PAC-SF44SRA Control range as Standard Controller (Air Outlet Angle/Air Filter) Limited room air temperature selection Auto diagnosis system 50 indoor units individual/max. 50 indoor units with 50 groups Lock-out function for PAR-F27 MEA External Input/Output System Timer PAC-YT34 STA PAC-YT34 STA Directly connected to the M-Net databus 50 groups/max. 50 indoor units Timer-controlled mode Timer-controlled temperature 9 Timer functions Lock-off selection (On/Off/Mode/Temperatue) 90

City Multi The New Controller G-50 A The Next Controller Generation G-50A Simple and flexible The central controller G-50 A is equally suitable for small and large systems. Web browser Use a standard web browser on your PC, e.g. Microsoft Internet ExplorerTM, to operate and monitor the air-conditioning unit, which is connected to your local Intranet, in comfort. Integrated software The easy to understand operating software is already integrated in the G-50 A. This represents Mitsubishi Electric s own innovation and is not Windows-based. It is therefore impossible for hackers to spy in your system data. Three password levels You can safeguard against unauthorised access to the air-conditioning system on three operating levels which are individually protected by passwords of your choice. Access to an air-conditioning unit (or group) e.g. for each office/floor but without the possibility to change the system settings Access to group and maintenance functions, e.g. for in-house technicians Access to the entire system, e.g. for the system administrator Remote access You can also operate your air-conditioning system with your PC by remote control via your local intranet or phone connection. The access is protected by a password of your choice. Automatic alarm If an error occurs, the G-50 A sends a message with the most important information to a mobile phone (SMS) or an email to an address of your choice. Always up-to-date Upgrades with continuously updated special functions are available for the G-50 A. Examples: Energy consumption data for individual cost statements Special economy programmes Annual schedules HARDWARE FOR G-50A Pos. Type Description 1 G-50A - Standard Standard central controller for 50 air conditioners 2 G-50A - Pro As above G-50 incl. Web function & annual schedule, programmed for clients demand 3 PAC-SC 50 KUA Power supply unit for G-50 4 BTX-1000 Router according to ME specification & installation is required depending to clients demands 5 PC* with software TG 2000 PC according Me specification & installation with OS, Internet Explorer and software TG 2000 6 Watt Hour Meter Amount of WHM is depend of the project SOFTWARE FOR G-50A Web Function Personal Web RC Power consumption Ratio Demand Control I Demand Control II Annual Schedule Data Export Error scanning function Auto Alarming Service BACnet PLC Set free Homepage Remote Control via PC Calculate individual cost*** Limit temperature range, optimize indoor-outdoor unit** Peak Cut*** only connection with PLC + PLC Software Weekly and Yearly Timer** Trend Graph*** Monitoring Error History Auto Alarm function Error Code mailing Maintenance Tool function BACnet Connection PLC connection direct with G-50 via RJ45 TG 2000 Installation TG 2000 software according customer requirement * Computer periphery like Monitor, Keyboard, Mouse, Printer from client ** Operation with G-50 or Pos. 5 *** Additional pos. 5 nessassary, for Power consumption ration additional Pos. 6 nessassary 91

City Multi Central Remote Control LonWorks Interface Maintenance Tool Lon Works -Interface L-MAP02-E Easy connection of City Multi Systems through LMAP02-E, the Lon Works -M-Net protocol converter, the total system requirements of engineers and end-users can be met more effectively and simply. 1 Lon Works -Interface manages 50 indoor units. Maintenance Tool - CMS-MNF-B Using Maintenance Tool is the easiest way for controlling, servicing and operating the City Multi system. All system information will be displayed on personal computer* screen based on Windows Software and settings can be changed. In addition, error code numbers are output onto the display. Easy maintenance is assured through the trouble history printer output and call functions. Besides ths connection with modem and data transfer is possible. CMS-MNF-B consists of converter box and software, RS-232 cable (cross) is needed. * Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, free space 10 MB on HDD. 92

City Multi Accessories CONTROLS MODEL REFERENCE DESCRIPTION PAC-SF48MA-E A to M-Net transmission converter PAC-SE40TS-E Temperature sensor PAC-725AD Remote indicator (Pack of 10) PAC-SA88HA-E Remote indicator (Pack of 1) PAC-SF46EPA Transmission booster ACCESSORIES MODEL REFERENCE PLFY-P-VKM/VAM-A PAC-SE06WP-E PAC-SE01AS-E PAC-SE60AS-E DESCRIPTION Wide panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P32/40/50/63 VKM-A Space panel for PLFY-P80/100/125 VAM-A PAC-SE13FK-E PAC-SG01KF PAC-SE21TM-E PAC-SG03TM-E PCFY-P-VGM-A PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAC-SE84DM-E PAC-SE85DM-E PAC-SE86DM-E PEFY-P-VML/VMH-A PAC-KE04DM-F PAC-KE32LAF-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F PEFY-P-VMM-A PAC-KE03DM-F PAC-KE32EDF-F PAC-KE50EDF-F PAC-KE80EDF-F PAC-KE125EDF-F PAC-KE140EDF-F PU(H)Y-P/PURY-P-YMF-B/C PAC-KBU02MT-F PAC-KBU03MT-F High efficiency filter for PAC-SE21TM-E High efficiency filter for PAC-SG03TM-E Multifunction casement for PLFY-P32/40/50/63 VKM-A Multifunction casement for PLFY-P80/100/125 VAM-A High efficiency filter for PCFY-P40 VGM-A High efficiency filter for PCFY-P63/100 VGM-A High efficiency filter for PCFY-P125 VGM-A Drain pump for PCFY-P40 VGM-A Drain pump for PCFY-P63 VGM-A Drain pump for PCFY-P100/125 VGM-A Drain pump for PEFY-P-VMH-A Replacement filter for PEFY-P20/25/32 VML Optional filter for PEFY-P40/50/63 VMH Optional filter for PEFY-P71/80 VMH Optional filter for PEFY-P100/125/140 VMH Optional filter for PEFY-P200/250 VMH Filter box for PEFY-P40/50/63 VMH Filter box for PEFY-P71/80 Filter box for PEFY-P100/125/140 Filter box for PEFY-P200/250 Drain pump for PEFY-P-VMM-A Round duct flange for PEFY-P20/25/32 VMM-A Round duct flange for PEFY-P40/50 VMM-A Round duct flange for PEFY-P63/71/80 VMM-A Round duct flange for PEFY-P100/125 VMM-A Round duct flange for PEFY-P140 VMM-A High static pressure motor, 30 PA for PU(H)Y-/PURY- P200/250 YMF-C High static pressure motor, (30) 60 PA for PU(H)Y-/PURY- P200/250/315 YEM-A REFRIGERANT PIPES CMY-R160-H Junction pipe kit for BC-Controller CMY-R160-HA Junction pipe kit for BC-Controller 2 x CMY-R160-H CMY-Y102S-F* Joint for capacity 160 or below CMY-Y102L-F* Joint for capacity from 161 up to 330 CMY-Y202-F* Joint for capacity from 331 up to630 CMY-Y302-F* Joint for capacity 631 or above CMY-Y104-F* Header (4 branch) CMY-Y107-F* Header (7 branch) CMY-Y1010-F* Header (10 branch) CMC-30A Super Y Kit *you can use also Standard T-Branch 93

Lossnay Ventilation Systems with heat recovery VL-Series/LGH-Series The sophisticated heat recovery technology of the Lossnay Element saves energy even while keeping your room comfortable. The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room. The system s benefit is to use the released cooling or heating energy for fresh air conditioning. 94

Ventilation without wasting energy Ventilation of buildings can waste considerable amounts of heating or cooling energy. The Lossnay system can utilise a high percentage of this energy to cut operating costs between 20% and 50% of the power what would otherwise be required to maintain a constant temperature. Save capital costs too By utilising this lost energy, the capacity of installed heating and cooling systems can also be reduced, with a consequent saving in capital costs of up to 30%. Lossnay units are designed to keep exhaust air and fresh air completely separate and yet still achieve an efficiency in the range of 60% to 70%. The fresh air then enters the room at a similar temperature to be expelled air, to provide comfortable environmental conditions all year round. Lossnay at work - and at home Lossnay total heat exchange ventilators are available in ranges for both commercial installations and residential use. LOSSNAY HEAT EXCHANGE SYSTEM Stale air expelled outside Outside air is drawn in Stale internal air recovery Renewed internal air Operating range Lossnay system VL-Series: t = -10 C bis 40 C, ϕ = 60% max LGH-Series: t = -10 C bis 40 C, ϕ = 80% max 95

Lossnay VL-Series Wall Mounted Systems Model VL-100 LOSSNAY-VL-SERIES MODEL REFERENCE VL-100U-E (V, PHASE,Hz) 220-240, 1, 50 POWER INPUT (W) Low 23 High 26 AIRFLOW Low 65 (m 3 /h) High 105 NOISE* Low 29.5 db(a) High 39 EFFICIENCY (%) Low 77 High 70 WEIGHT (kg) 6.5 DIMENSIONS (mm) Width 620 Depth 168 Height 265 DUCT SIZE (mm) 2x75ø To install the units of the Lossnay Series VL-100 only 2 x 75 mm diameter bores are necessary. Supply and return air ducts and protective caps against invading rain water are included in delivery. The units operate very quietly, selection between 2 fan speed levels is possible, the unit will be switched on/off by pull string. * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Lossnay LGH-Series Ceiling Suspended Systems Model LGH-40ES-E LOSSNAY-LGH-SERIES MODEL REFERENCE LGH-40ES-E 220-240, 1, 50 (V, PHASE,HZ) POWER INPUT (W) low 88 high 138 RUNNING CURRENT (A) low 0.4 high 0.6 AIRFLOW (m3/h) low 250 high 400 STATIC PRESSURE (Pa) low 10 high 40 NOISE* db(a) low 33 high 42 TEMPERATURE RECOVERY low 70 (%) EFFICIENCY high 60 ENTHALPY RECOVERY low 52 (%) EFFICIENCY high 45 WEIGHT (kg) 25 DIMENSIONS (mm) WIDTH 900 DEPTH 693 HEIGHT 255 DUCT SIZE (mm) 2 x 200 ø OPTIONAL PARTS MODEL REFERENCE PZ-03SLP-E Switch ON/OFF and Airflow * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Compact Design A mere 255 mm from front to back, this thin design takes up a minimum of space even when suspended from the ceiling of an existing building. Minimal installation needs In addition to this lightweight and compact design, connection to the outdoor unit requires just a 200 mm. Saves energy The simultaneous intake/exhaust of air together with the Lossnay core recovers temperature and humidity from the room while ventilating, making this unit both economical and environmentally friendly. A refined design Designed to eliminate the outflow of air to the space directly beneath the unit, there is no worry of discomfort from drafts. 96

Lossnay LGH-Commercial Series Models LGH-15 to 200 RX Saves between 20% and 50% of the energy that would otherwise be lost by ventilation Saves up to 30% on initial capital costs of heating and cooling plant due to Lossnay s ability to utilise heating or cooling energy that would otherwise be wasted Automatically humidifies or dehumidifies incoming air to match required interior conditions Supply air and exhaust air are kept strictly separated to ensure inbound air is always fresh Supply air is heated or cooled as required to match room conditions Provides comfortable ventilation through introduction of fresh air, helping to provide a healthy working environment Minimal Maintenance Easily replaced Lossnay element LOSSNAY-LGH-SERIES MODEL REFERENCE LGH15RX LGH25RX LGH35RX LGH50RX LGH80RX LGH100RX LGH150RX LGH200RX (V,PHASE,Hz) 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 RUNNING CURRENT (A) 0.52 0.55 0.82 0.96 1.8 2.3 3.3 4.6 POWER INPUT (W) Low 52 54 97 123 304 465 585 900 Medium 74 91 154 193 368 495 670 995 High*** 104 111 169 204 392 500 720 1000 AIRFLOW Low 120 165 230 350 670 870 1200 1400 (m 3 /h) Medium 150 250 350 500 800 1000 1500 2000 High*** 150 250 350 500 800 1000 1500 2000 STATIC PRESSURE (Pa)* Low 25 20 25 30 70 80 50 83 Medium 40 40 70 60 100 100 100 80 High*** 90 65 150 150 140 160 137 137 NOISE** Low 21 21 23 24 30 32 33 36 db(a) Medium 24 25 28 30 32 34 36 37 High*** 26 27 31 32 34 36 37 39 EFFICIENCY % Low 80 93 84 82 81 81 81 83 Medium 77 78 79 77 78 79 79 79 High*** 77 78 79 77 78 79 79 79 WEIGHT (kg) 19 23 33 38 73 83 175 194 DIMENSIONS (mm) Width 610 735 874 1016 1004 1221 1004 1231 Depth 780 780 888 888 1164 1164 1662 1662 Height 275 275 317 317 398 398 800 800 DUCT SIZE (mm) 100ø 150ø 150ø 200ø 250ø 250ø 350ø 350ø *** Refering to the airflow in the table *** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Extra high ventilation step to increase stat. pressure ACCESSORIES LOSSNAY MODEL REFERENCE DESCRIPTION PZ-41SLB WIRED REMOTE Control for independent operation PZ-52SF Remote Controller for City Multi System 97

MJ-E16PX Dehumidifier Easy to operate by LCD display 3 operating modes: low, high and auto protection Air filter Display of defrost Waterlevel visible Large water container (6 L) Automatic stop by overflow Timer: 1 9 hours operation Hygrostat Display of humidity (50%, 60%, 70%) voltage break Automatic restart after Collects up to 16 litres of moisture in a 24 hours period Compact, unobstrusive and quiet in operation Low energy consumption Environment-friendly refrigerant R134a Compact and efficient MJ-E16PX seems unobstrusive and is portable because of its grip and weight (12.9 kg). Additional Advantages Reduces the time of drying your clothes on the line Installation of a hose possible to transport the condensate water MJ-E16PX DEHUMIDIFYING CAPACITY Litres/24 hours 10 C/70% rel. humidity 3.1 27 C/60% rel. humidity 9.0 30 C/80% rel. humidity 16.0 TECHNICAL DATA Water container (I) 5.0 Auto Stop (I) 5.0 Weight (kg) 12.9 Dimensions (mm) Width 360 Depth 281 Height 569 Supply voltage (V, Phase, Hz) 220-240, 1, 50 Power consumption (W) 280 Noise db(a) Low 33 in fan operation High 35 Operating temperature min. 1 C max. 40 C Compressor type Rotary Refrigerant R134 a Colour white MJ-E16PX CONTROL FUNCTIONS Mode button Timer button Control lamp Tank full lamp Defrost lamp Humidity lamp selects low, high and auto press to set operation time 1 9 hours or permanent shows adjustment lights when water tank needs emptying light is on during defrost operation lights when extremely high rel. humidity, audible signal for rel. humidity more than 70% 98

Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B. V. The Company reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company s General Conditions of Sale, a copy of which is available on request. Art. No. 154384 05/2004 MITSUBISHI ELECTRIC EUROPE B.V. AIR CONDITIONING DIVISION GOTHAER STR. 8 D-40880 RATINGEN GERMANY TEL.: +49-2102-486-1800 FAX: +49-2102-486-7910 www.mitsubishi-electric-aircon.de