Head: The new space race



Similar documents
OEH Energy Efficient HVAC for Business Training Course

ASTACEA4 Inspect complex/central air conditioning systems

250 St Georges Tce, Perth, WA (QV1)

Scope of Work. See for resources available

Australian/New Zealand Standard

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Fläkt Woods Building Future

HEATING, VENTILATION & AIR CONDITIONING

Challenges and Failures in Green Building Design Using Under-Floor Air Distribution. Ken Urbanek, PE, HBDP, LEED AP Director of Engineering

Building Energy Codes 101 October 23, Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Energy Efficient HVAC-system and Building Design

Seminar 2: HVAC Management and Improvement Opportunities

PROTOCOL FOR BUILDING ENERGY ANALYSIS SOFTWARE For Class 3, 5, 6, 7, 8 and 9 buildings

Green and Energy Efficient Homes What you need to know

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

HVAC Systems: Overview

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

Case Study. Commercial Building Energy Efficiency Retrofit 4 Mort Street, Canberra. Results. Background PEOPLE PRACTICES SYSTEMS

Integrated Solar Radiant Systems

New Zealand BIM Handbook Appendix D - BIM Uses definitions July A guide to enabling BIM on building projects

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

Automated Commissioning for Energy (ACE) Platform for Large Retail Property. Overview

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Acoustic Design Practices for Sustainable Buildings

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Using Autodesk Fabrication Software from TSI

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Optimization of Water - Cooled Chiller Cooling Tower Combinations

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Paolo Musso, Stam S.r.l.

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

The Enhanced Capital Allowance scheme for energy-saving technologies. A guide to equipment eligible for Enhanced Capital Allowances

Heating, ventilation and air conditioning zone controls

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

2014 British Columbia Building Code Changes

EnergyPro Building Energy Analysis. Assisted Living Building

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Printing and Publishing Energy Savings Guide

Energy Efficiency HOSPITALITY.

SANS XA Energy usage in buildings: An architect s guide to compliance in home design

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Cool air quietly and efficiently. A guide to buying and operating an air conditioner

Mechanical Systems Proposal revised

Energy Efficiency. Bars & RestauRants.

We ve got you covered.

Air conditioning is AIR CONDITIONING GUIDE

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

How To Design An Hvac Design For A Stick Built Home

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

SECTION GENERAL PROVISIONS FOR HVAC WORK

Glossary of Heating, Ventilation and Air Conditioning Terms

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Mechanical insulation to increase building efficiency. Saving money, energy and the planet.

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

RESNET National Rater Test Study Guide Outline

Your Guide to Buying an Energy-Efficient Central Air Conditioner

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Element D Services Heating, Ventilating, and Air Conditioning

Introduction to Energy Codes & Green Building Programs

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

PFT Two stage axial fan The high pressure fan for modern boiler plants

WHITE PAPERS. Food Processing Plant Design

All the best brands all under one roof

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Variable Refrigerant Flow Systems

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

FIRE DETECTION BUILDING AUTOMATION CAPITAL PROJECTS HVAC SERVICES SECURITY SYSTEMS PROJECT MANAGEMENT.

VRF Zoning: An Ideal HVAC Solution for Multifamily Applications

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

for Revit MEP The professional s choice for Building Services

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

Before You Start an Energy Efficiency Retrofit The Building Envelope

Building Energy Modelling. prescriptive

ENERGY STAR Data Verification Checklist

The Integrated Design Process

EarthCents (DSM) Program Summary

Acoustics & Building Services An back to basics overview

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

The Different Types of Air Conditioning Equipment for IT Environments

Energy Saving Fact Sheet Boilers

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Transcription:

Head: The new space race Intro: Since 2010, NCC BCA Section J Deemed-To-Satisfy requirements for limiting the power used by HVAC fan and pump motors has resulted in an increase to system duct and pipe sizes. At the same time, Section J has also increased minimum insulation R values and has moved to a Material R value basis for insulation systems, leading to increased thicknesses for traditional materials. Although increasing the energy efficiency of building services systems is an essential action to control building-related energy use, the combined effect of these three changes has led to an increase in the spatial requirements of the services that need to fit into the plant rooms, shafts and ceiling spaces of BCA Deemed-To-Satisfy compliant buildings. In this view from all sides article, Vince Aherne, M.AIRAH, speaks to four experts about how the construction industry is dealing with these spatial issues. Ever since humans first started erecting buildings, there has been conflict around providing space for building services. In days past this might have involved allowing space for tall ceilings to facilitate ventilation and comfort, or inserting large, high windows for adequate day lighting. In many contemporary buildings the indoor environmental conditions are provided by building services systems, which all need to be accommodated within the often-hidden building spaces of plant rooms, shafts, false ceilings and raised floor spaces. Sub-head: Smash the myth: GREEN HVAC is not lean HVAC There is a myth pervading the industry that being green means being lean, and that energy-efficient HVAC systems are somehow smaller than standard systems, says Scott Brown, M.AIRAH, sustainability director with Waterman Group. The truth is that while a green building might reduce dependency on HVAC, all things being equal, Brown says that energy-efficient HVAC systems are more likely to lead to an increase in spatial requirements, not a decrease. He says bigger ducts with more insulation need bigger shafts and deeper ceiling spaces. More efficient chillers and boilers need bigger heat exchangers, with more plantroom access. A greener system configuration with air-to-air energy recovery, for instance, means more ductwork and additional heat exchangers to fit in, Brown says. Brown notes that plant rooms with energy-efficient HVAC plant and air-to-air heat recovery can be 50 per cent or even 100 per cent bigger than they would have been had energy efficiency not been a concern.

Mark Lee, Affil. AIRAH, is engineering manager with mechanical contractor James L Williams. He says that generally speaking, building designers allocate the same or smaller spaces for building services as they have in the past, making access tight and providing for future maintainability very difficult. So the same old battles are being fought by designers. It is not the cost of larger ducts or plant that is the issue, says Lee. It is the cost of the additional space required that seems to be the limiting factor. Space, in other words, is the crunch point. Sub-head: The race for space Jason Veale, associate director building engineering with AECOM, agrees. Every project has a degree of tension between architects and engineers over spaces, he says. Section J is now increasing the need to coordinate and communicate about service space early. According to Peter Cass, M.AIRAH, who is associate services cost management with Rider Levett Bucknall, architects are pivotal to changing space allowances because they own the building spaces. But as Cass explains, extra space is not always a straightforward proposition. Developers are measuring new projects against the space ratios of the existing buildings that will compete for the same tenants, Cass says. Cass says that to some developers, any non-lettable space is viewed as wasted. Brown, Cass and Lee all agree the reality is that allocating additional space is very expensive. Construction costs will change, which affects the profitability of an entire project. There may be occasions when bigger shafts might be accommodated, says Veale. But deeper ceiling spaces? No way. So, all agree that there has been no apparent change in spatial allowances for services, and that building floor-to-floor heights have not changed. The reality is that, in most cases, larger services are being squeezed into the same or smaller spaces to the point that coordination is almost impossible, Lee says. Although new tools such as BIM software and visualisation or clash-detection tools can predict and highlight clashes between services, it is the practicalities around the space needed for installation that is a key pressure point on site.

The pressures exerted by architects, designers and builders mean that on site, it becomes a race to install your services first so that the other trades have to work around you, Lee says. Though 3D building models are useful tools for laying out services, they do not solve all the issues around access for installation. Sub-head: Old solutions can no longer be applied Lack of services space has always been a barrier to optimum performance. In the past, when a clash with existing services or immovable structural component was encountered, distribution systems could be made to work, by flattening ductwork or installing aerodynamically restrictive bends. Some of these transitions are quite extreme, and these types of solutions reduce system energy efficiency. In fact, they are exactly the type of thing that the NCC Section J rules are attempting to address. As Veale says, duct routes are often chosen with little regard to the impact on overall fan energy. Restrictions at the inlet and outlets of fans and air-handling units can significantly degrade the expected system performance. The motor power and energy consumed rises as the resistance along the distribution route goes up. Now these make-it-work options are no longer available due to overall power restrictions, so what is an industry to do? Sub-head: What are the solutions? Apart from providing additional space for services accommodation, there are a few alternative options available. The market is always keen to respond, and some HVAC solutions have different spatial requirements than others, Cass says. Brown notes that chilled beam systems tend to be more space efficient, and can be left exposed if aesthetically desirable. Cass agrees, and notes that distributed systems for example, many smaller systems rather that single, large central systems and underfloor air distribution systems, are also becoming popular, for a variety of reasons, including space considerations. Cass also says chilled and/or heated structures (floors, walls, ceilings) are another option that is being adopted to keep ahead of the curve for building design. However, as Brown points out, these solutions themselves tend to have a significant cost premium over the more standard HVAC methods, and this all needs to be added into the mix. Also, these solutions, if not correctly and appropriately implemented, can lead to issues with indoor air quality, condensation and mould.

All our experts agree that new attitudes regarding energy efficiency must be developed by architects, developers, and by the eventual building owners and tenants. Building designers and developers are well aware of the benefits of energy-efficient services systems, Lee says. Those benefits generally flow to the occupier, who is often not the building owner, nor the entity paying the construction costs. So the same old split-incentive barriers apply. Asks Cass: Why should a developer or building owner pay additional construction costs to reduce operating costs for future tenants? Green leases go some way to addressing this, as do building rating systems that can be used to market a building for sale or lease. Engineers need to push harder and sell the merits of increased services space to designers and builders, Cass says. Green Star and NABERS do a great job of recognising buildings designed with improved energy efficiency, says Cass, adding that this includes HVAC systems that have larger ducts and pipes. Eventually end users will drive this agenda when they begin to favour (that is to say, pay more for) energy-efficient building spaces. In addition, as Lee points out, there are many other benefits of increased or reasonable services space, including less wastage and rework on site due to services clashes, faster installation time, reduced installation costs, and better access for maintenance and inspection for the life of a system. These benefits also need to be recognised. Sub-head: Alternative solutions; life is a trade-off It is becoming increasingly common now for designers to use the alternative JV3 modelling approach to reduce insulation requirements for pipes and ducts to avoid increases in ceiling depths, Veale says. JV3 modelling allows trade-offs between system components because it is the overall performance of the system that is assessed. Over-complying on performance for chillers, pumps, fans and lighting can allow for a relaxation of insulation requirements and still produce an equivalent overall energy result, Veale says. A bigger chiller in the plant room might allow a smaller duct on the occupied floors, for instance.

If spaces are going to be squeezed to the extent that it affects the profitability of the project then JV3 is used to avoid that situation, Veale says. JV3 modelling almost always improves the situation significantly, and the modelling and design work comes at a fraction of the cost of losing a floor off the top of a building. Sub-head: How can the awareness of these issues be raised within the industry? One suggestion from Lee about how awareness can be raised is the introduction into the NCC of minimum aspect ratios for ducts, or a standard calculator, like that used for glazing. This would help consultants and contractors prove to builders that a system will not comply if it is forced into the restrictive spaces they propose. Says Brown: Education and awareness building is the key. The myth that green always means lean for HVAC systems needs to be broken. A suggestion from Veale is for engineers to document the final insulated dimensions of the ductwork, and not the sheet metal dimensions. Design drawings often show sheet metal sizes for pricing; construction drawings often show sheet metal sizes for fabrication. Yet these metal sizes are generally not the final spatial size required if the duct is to be externally insulated. All agree that the design team needs to establish the spatial requirements very early in the process so it can be accommodated, and make sure all stakeholders know why it is occurring. A good design team will have a workshop to deal with it, says Veale. Communications around spatial requirements need to be ongoing as the project progresses. Sub-head: Is better integration in the design process the key? The balance of benefits and costs does not appear to have been addressed holistically within building regulations, Brown says. A lot of attention has been given to the final energy efficiency of HVAC plant, but little given to the additional space, materials and embodied energy required to implement such plant. Given the imperative to reduce the energy consumption of buildings, it is surprising that building services one of the major components of energy usage and cost are rarely considered in the early stage of a design or as potential driving factors for form and spatial configuration. It is the building orientation, form and fabric aspects that generally dominate the cooling and heating loads. In order for the form and geometry of buildings to be considered in response to energy efficiency and building services optimisation, multidisciplinary integration is required in the early stages of the design process, when the design proposal is still flexible.

So, to sum up, energy-efficient HVAC tends to be bigger than standard HVAC. Energyefficient and green buildings tend to provide the same or less space for services than standard buildings. Something has got to give. Engineers push for more space, and architects and developers push back or resist. The final answer is somewhere in between, after both engineer and architect have pushed to be as efficient in their spatial requirements as possible. JV3 energy modelling offers an alternative compliance path for those buildings and systems that encounter significant problems with NCC-driven Deemed-To-Satisfy pipe and duct sizes. End box: AIRAH would like to thank the following individuals for sharing their views in this article with Vince Aherne, M.AIRAH: Scott Brown, M.AIRAH, sustainability director Waterman Group Peter Cass, M.AIRAH, associate, services cost management Rider Levett Bucknall Mark Lee, Affil.AIRAH, engineering manager James L Williams Jason Veale, associate director, building engineering AECOM.