LifeCycle: Example LCA Studies <Virtual Environment> 5.9



Similar documents
VRF Life Cycle Cost Analysis. January 23, 2011

FINANCIAL EVALUATION OF ENERGY SAVING PROJECTS: BUILDING THE BUSINESS CASE

HOW TO TAKE YOUR GAS AND ELECTRICITY METER READING

FLORIDA LIFE-CYCLE COST ANALYSIS PROGRAM For Sustainable State Agencies

Case Study (part II)

HVAC System Optimization Program Guidelines

Comparison of Natural Gas, Electricity, & GeoExchange Systems in a Saskatchewan Building Study Performed in Cooperation with Canadian GeoExchange

Energy Audits. Good energy management begins with an energy audit

Fire? Loss of Profits? 3. What company covers the machinery to be insured under a Machinery Breakdown Policy?

Problems on Time value of money January 22, 2015

ASSET & FACILITIES MANAGEMENT CORPORATE ENERGY EFFICIENCY POLICY

Directive EC 2008/92 on Gas and Electricity Prices Kyiv, 7 October 2014 Damir Pešut, Senior Expert

DATA CENTRE DESIGN AND

November 2014 WWW. E L L I N A N D T U C K E R. C O M

Data Center UPS Systems Why 1% Efficiency Matters

Energy Saving by ESCO (Energy Service Company) Project in Hospital

TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES

Recommendations for Measuring and Reporting Overall Data Center Efficiency

MODULE 2. Finance An Introduction

Electric Power Monthly with Data for October 2015

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Accounting Notes. Types (classifications) of Assets:

FINAL REPORT LIFE-CYCLE COST STUDY OF A GEOTHERMAL HEAT PUMP SYSTEM BIA OFFICE BLDG., WINNEBAGO, NE

MINARA RESOURCES LIMITED First Public Report

COMPUTER APPLICATIONS IN HVAC SYSTEM LIFE CYCLE COSTING

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Closed-Loop Ground-Coupled Heat Pump Systems

Six Functions of a Dollar. Made Easy! Business Statistics AJ Nelson 8/27/2011 1

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

COMPARATIVE ANALYSIS OF THE VRF SYSTEM AND CONVENTIONAL HVAC SYSTEMS, FOCUSED ON LIFE-CYCLE COST

Idaho Energy and Cost Savings

The Secondary Impact of System Optimisation on Building Equipment; Maintenance and Life Expectancy

ADVANCED INVESTMENT APPRAISAL

The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes

Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

INTRODUCTION Tariff Objective Factors

Q Utility Rebate Report. Fort Worth, TX

How To Read The Book \"Financial Planning\"

Energy and Cost Savings

Proposal prepared for Happy Solar Owner

Indiana Energy and Cost Savings

Georgia Energy and Cost Savings

FINANCIAL SUPPORT PROGRAMS

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Colorado Energy and Cost Savings

UISTRIBUTION STATEMENT A Approved for Public Release Distribution Unlimited

ENERGY EFFICIENCY IN BUSINESS PLANNING ENERGY EFFICIENCY FACT SHEET

Draft consolidated baseline and monitoring methodology ACM00XX

Sam E. Chapple, P. Eng. Chief Technical / Business Development Officer

Case Study. Crown Melbourne & BUENO Systems: Energy and Operational Savings Across a Multi-Use Entertainment Complex.


2. (a) Express the following numbers as products of their prime factors.

Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

3.2 TENDER FOR MAINTENANCE OF HEATING VENTILATION AIRCONDITIONING (HVAC) EQUIPMENT AND ASSOCIATED WORKS (CF :RR)

RESPONSE TO PUB ORDER 117/06. PUB Order 117/06 Directive 6

LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING

Module 5: Interest concepts of future and present value


Levelised Unit Electricity Cost Comparison of Alternate Technologies for Baseload Generation in Ontario

Time Value of Money Level I Quantitative Methods. IFT Notes for the CFA exam

Systematic Approach to Developing a Priority List Using the Weatherization Assistant

Large Company Limited. Report and Accounts. 31 December 2009

Communicating the Value of Energy Efficiency Projects to Financial Decision Makers in Not-For-Profit Markets

Rules & Regulations Handbook

Harmonizing Global Metrics for Data Center Energy Efficiency. Global Taskforce Reaches Agreement Regarding Data Center Productivity.

The Time Value of Money

Electricity & Gas Prices in Ireland. 2 nd Semester 2009

184. PROFILE ON MICRO FINANCE SERVICE

Energy Audit Skills: Tools, Data Collection Techniques and Calculations Spring 2012

A Guide For Preparing The Financial Information Component Of An Asset Management Plan. Licensing, Monitoring and Customer Protection Division

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Time Value of Money Level I Quantitative Methods. IFT Notes for the CFA exam

The Effect of Natural Gas Supply on Retail Electricity Prices

Coop City Riverbay Corp. Site - Data Integrator Notes

HOW A DC UTILITY METER CAN TRANSFORM THE U.S. SOLAR INDUSTRY

Electricity & Gas Prices in Ireland

PROFILE ON SHEEP AND GOAT FARM

IES <Virtual Environment> training. Trainee notes. ASHRAE 90.1 Appendix G - PRM Navigator. Version

CRITICAL COOLING FOR DATA CENTERS

Best Practice Guide BPGCS007

E.ON s UK Consolidated Segmental Report for the year ended 31 December 2014 Amended copy published 11th May 2015

IV. Rear Mount System

QUESTIONNAIRE AND PROPOSAL FOR LOSS OF PROFITS FOLLOWING MACHINERY BREAKDOWN INSURANCE

ENERGY AUDITS (OR SURVEYS) & ENERGY MANAGEMENT PROGRAMS SECTION B

BENEFIT-COST ANALYSIS Financial and Economic Appraisal using Spreadsheets

LIFE CYCLE COST CALCULATIONS

Performance Contracting

11 PERFORMING FINANCIAL ANALYSIS

The Cost of Capital, and a Note on Capitalization

Analysis of HVAC Control Strategies

Chapter 4.11: Financial Management

Details of Rate, Fee, and Other Cost Information

Integrated Case First National Bank Time Value of Money Analysis

An Estimate of Energy Use in Laboratories, Cleanrooms, and Data Centers in New York

ČEZ, a. s. BALANCE SHEET in accordance with IFRS as of March 31, 2015 in CZK Millions

GHG Accounting Guidance Note Manufacture of Renewable Energy Climate Related Products

Richard Sweetser, Principal Investigator, EXERGY Partners Corp. Phone:

6. FINANCIAL MANAGEMENT

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Energy Tutorial: Energy Usage. Reading meters and understanding fuel bills

Transcription:

LifeCycle: Example LCA Studies <Virtual Environment> 5.9 Page 1 of 15

Contents 1. Introduction...3 2. Test Example 1: HVAC System for US Federal Office Building...4 2.1. Option 1: Constant Volume HVAC System... 4 2.2. Option 2: Alternative Energy Saving Design... 7 2.3. Comparative Analysis... 8 3. Test Example 2: HVAC System for US Federal Office Building...9 3.1. Option 1: Base Case Conventional Design... 9 3.2. Option 2: Alternative Energy Saving Design... 12 3.3. Comparative Analysis... 14 4. References...15 Page 2 of 15

1. Introduction LifeCycle is a module in the IES <Virtual Environment> system. LifeCycle is part of the VE/Cost product group and it enables users to undertake Life Cycle Analysis (LCA) studies. This document assumes you have a working knowledge of LCA and LifeCycle. In the following pages several LCA calculations published by the US Department of Energy are entered into LifeCycle and the results compared. This document serves two functions: 1. The accuracy of the LifeCycle algorithms is demonstrated. 2. Due to the complexity of the LCA examples, an explanation of how to assign different LCA elements to the different categories available in LifeCycle. This should help users better understand the facilities available in LifeCycle. Page 3 of 15

2. Test Example 1: HVAC System for US Federal Office Building This example is taken from the Life-Cycle Costing Manual published by the US Department of Energy [1]. In this first example two options are considered. The basic information is as follows: Location: Washington DC, DOE Region 3 Discount Rate: Current FEMP discount rate Energy Prices: Electricity at $0.08/kWh Discount Factor: FEMP UPV* factor based on a 3% (real) discount rate Useful Life of System: 20 years Study Period: 20 years As this is a US case study we will use $US as the currency in LifeCycle. In the US they use published tables to calculate discount rates to three decimal places. This can cause some minor rounding errors. 2.1. Option 1: Constant Volume HVAC System The base case is a constant volume HVAC system. The relevant cash flows are as follows: Initial Investment: $103,000 assumed to occur in a lump sum. Electricity: $20,000 per annum (250,000 kwh at $0.08/kWh). Operating, Maintenance and Repair: $7,000 Annual cost. Fan Replacement: $12,000 at the end of Year 12. Residual Value: $3,500 at the end of the study period (20 years). We then need to decide the best category or tab in LifeCycle to place each of these costs. Page 4 of 15

LifeCycle Category Description Rates Set the study period to 20 years and the discount rate to 3%. The electrical discount rate is based upon the electrical price escalation rates projected by the US DOE. From the current tables provided by the DOE the sum of these annual values over 20 years is 15.13. This value is normalised in LifeCycle to be 2.82% over 20 years. Capital Initial Investment of $103,000. Energy There are two options for entering electricity costs: 1. Put in a fixed cost of $20,000 in the electricity cost element. 2. Enter a Standing Charge of zero and a cost/kwh of 0.08. Use one of the electricity components e.g. lighting and enter 250,000 kwh with a COSP of 1.0. Set all other values to zero and LifeCycle will calculate electricity cost of $20,000. Annual O, M & R of $7,000. Repair Fan replacement of $12,000 in Year 12. Residual Value of -$3,500 in Year 20. This is a negative value as it is an income. In LCA expenditures are positive and income is negative. Other None. The published LCA results [1] as follows: Page 5 of 15

The results from LifeCycle are: The differences are insignificant as they are rounding errors created because the discount factors used in the FEMP calculation are from tables rounded to the third significant figure whereas in LifeCycle they are more accurately calculated. Page 6 of 15

2.2. Option 2: Alternative Energy Saving Design The alternative is a constant air volume system with a reciprocal chiller, nighttime setback for heating and air conditioning, and economiser cycle. The relevant cash flows are as follows: Initial Investment: $110,000 assumed to occur in a lump sum at the base date. Electricity: $13,000 per annum (162,500 kwh at $0.08/kWh). Operating, Maintenance and Repair: $8,000 Annual cost. Fan Replacement: $12,500 at the end of Year 12. Residual Value: $3,700 at the end of the study period (20 years). We then need to decide the best category or tab in LifeCycle to place each of these costs. LifeCycle Category Description Rates As Case 1 the study period is 20 years, the discount rate is 3% and the electrical discount rate is 2.82%. Capital Initial Investment of $110,000. Energy The Standing Charge was set at zero and the cost/kwh was 0.08. The lighting electricity component was given 162,500 kwh with a COSP of 1.0. All other values were set at zero. LifeCycle calculated electricity cost of $13,000. Annual O, M & R of $8,000. Repair Fan replacement of $12,500 in Year 12. Residual Value of -$3,700 in Year 20. Other None. The published LCA results [1] for Option 2 are: Page 7 of 15

The results from LifeCycle are: The differences due to rounding errors created in the FEMP calculation. 2.3. Comparative Analysis The best option over the period of the study is the options with the lowest life cycle cost. In this case, from LifeCycle: Option 1 is $516,183 Option 2 is $432,404 Hence Option 2 provides a Net Saving of $83,779 over twenty years. Remember this is over and above the 3% rate of return already taken into account through the discount rate. Page 8 of 15

3. Test Example 2: HVAC System for US Federal Office Building This example is taken from the Life-Cycle Costing Manual published by the US DOE [1]. The basic information is the same as Test Example 1. However, the problem has been made more complex due to the following changes: The initial costs of the HVAC system will be phased in over an initial two year period. This will extend the study period by two years to 22 years i.e. two years pre-service followed by a 20 year service period. The useful life of both systems is different: 15 years for the base case and 20 years for the alternative. The replacement cost of the base system after 15 years will be $60,000 to prolong its life to at least 20 years. This will result in a higher residual value of $20,000 at the end of the 20-year service period. Both systems use electrical and natural gas. 3.1. Option 1: Base Case Conventional Design The base case is a constant volume HVAC system. The relevant cash flows are as follows: Initial Investment: $103,000 over two years pre-service. Electricity: 125,000 kwh at $0.08/kWh per annum. Fuel: 1700 GJ at $5.93/GJ per annum. Operating, Maintenance and Repair: $7,000 Annual cost. Fan Replacement: $12,000 at the end of Year 14 of study, i.e. Year 12 of service life. Plant Replacement: $60,000 at the end of Year 17 i.e. Year 15 of service life. Residual Value: $20,000 at the end of the study period i.e. Year 22. Page 9 of 15

These costs are then entered into the following LifeCycle categories: LifeCycle Category Rates Capital Energy Annual Repair Other Description Set the study period to 22 years and the discount rate to 3%. The electrical discount rate, based upon the electrical price escalation rates projected by the US DOE is normalised in LifeCycle to be 2.82%. The fuel discount rate, calculated in the same way, is 1.32%. None. The capital costs have now been assigned to Repair costs in Years 1 and 2. We could also have entered these costs via the Other category in LifeCycle. Electricity: 125,000 kwh at $0.08/kWh per annum entered as before. However, fuel is 1700 GJ at $5.93/GJ per annum. Therefore to incorporate this information, go to the Fuel option in Energy and enter 5.93 into the rate and 1700 in the Fuel and set the COSP at 1.0 (because these figures are fuel consumption and system efficiency is already incorporated). None. First instalment of plant: $51,500 in Year 1. Second instalment of plant: $51,500 in Year 2. Fan replacement of $12,000 in Year 14. Plant Replacement of $60,000 in Year 17. Residual Value of -$20,000 in Year 22. The Annual Maintenance costs have been move to this facility because there are no O, M & R costs in the first two years. With this option we can define these costs between Year 3 and Year 22. The results calculated are [1]: Page 10 of 15

The results from LifeCycle are: The differences are due to rounding errors in the discount factors used in the FEMP calculation. Page 11 of 15

3.2. Option 2: Alternative Energy Saving Design The alternative is similar to Option 2 of Test Example 1. The relevant cash flows are as follows: Initial Investment: $110,000 over two years pre-service. Electricity: 100,000 kwh at $0.08/kWh per annum. Fuel: 1180 GJ at $5.93/GJ per annum. Operating, Maintenance and Repair: $8,000 Annual cost. Fan Replacement: $12,500 at the end of Year 14 of study, i.e. Year 12 of service life. Residual Value: $3,700 at the end of the study period i.e. Year 22. These values are entered in LifeCycle as follows: LifeCycle Category Rates Capital Energy Annual Repair Other Description As Case 1 the study period is 20 years, the discount rate is 3% and the electrical discount rate is 2.82%. Initial Investment of $110,000. The Standing Charge was set at zero and the cost/kwh was 0.08. The lighting electricity component was given 162,500 kwh with a COSP of 1.0. All other values were set at zero. LifeCycle calculated electricity cost of $13,000. O, M & R of $8,000. Fan replacement of $12,500 in Year 12. Residual Value of -$3,700 in Year 20. None. Page 12 of 15

The results calculated are [1]: Page 13 of 15

The results from LifeCycle are: The differences are due to rounding errors created in the FEMP calculation. 3.3. Comparative Analysis From LifeCycle the life cycle costs for both these two options are: Option 1 is $545,230 Option 2 is $457,360 Hence Option 2 provides a Net Saving of $87,870 over the project life. Remember this is over and above the 3% rate of return already taken into account through the discount rate. Page 14 of 15

4. References [1] Fuller, S.K. and Petersen, S.R., Life Cycle Cost Manual for the Federal Energy Management Program, NIST Handbook 135, February 1996. Page 15 of 15