Instructions. Setup of Teamviewer VPN. programming remotely With STEP7.



Similar documents
1 PC to WX64 direction connection with crossover cable or hub/switch

How to connect your new virtual machine to the Internet

Application Note Configuring the UGate 3000 for use with ClipMail Pro and ClipExpress

Self Help Guide. Please read the following carefully; Synopsis: Requirements: A Computer with a working RJ45 LAN Port All Belkin Modem Routers

Internet Access to a DVR365

Software Installation Guide

1. Hardware Installation

Quick Installation Guide Network Management Card

From a Finder window choose Applications (shown circled in red) and then double click the Tether icon (shown circled in green).

WestermoConnect User Guide. VPNeFree Service

Software Installation Guide

How to configure DVR and computer for running Remote Viewer via IP network

For extra services running behind your router. What to do after IP change

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

LAN TCP/IP and DHCP Setup

C-more Remote Access with Apple ipad or iphone Tutorial

Pre-lab and In-class Laboratory Exercise 10 (L10)

Compulite File Server

TN Using FileZilla FTP Server with a DT80 Series Logger

Self Help Guide IMPORTANT! Configuring Your Router With Your Modem. Please read the following carefully; This Guide refers to the following Products:

VPN Configuration of ProSafe VPN Lite software and NETGEAR ProSafe Router:

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Steltronic Focus. Main Desk Internet connection

How to Remotely Access Hikvision Devices User Manual

Operating Instructions

Classroom Management network FAQ and troubleshooting

VPN Configuration of ProSafe Client and Netgear ProSafe Router:

Firewall VPN Router. Quick Installation Guide M73-APO09-380

SNMP Manager User s Manual

Configuring Routers and Their Settings

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

If you never used nor intend to use the wired-connection, then please disregard the following info.

Multi-Homing Dual WAN Firewall Router

Connecting the DG-102S VoIP Gateway to your network

3.5 EXTERNAL NETWORK HDD. User s Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Recommended Network Setup

How to Setup and Connect to an FTP Server Using FileZilla. Part I: Setting up the server

Setting Up Internet Connection Sharing (ICS) on a Server

Applications & Tools. Remote Control Concept with SCALANCE S Modules over IPsec-secured VPN Tunnel SCALANCE S. Application Description February 2010

How to connect NUVICO DVR to the internet

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

This guide is intended to help you troubleshoot problems connecting a wireless device to the Gogo Biz network.

Operating Instructions

Instructions for transferring the SINUMERIK HMI to an external screen

Guide to Setting up Internet Connection Sharing for Windows

Service & Support. How do you create a communication of RDP with an Industrial Thin Client SIMATIC ITC? Thin Client.

Networking your DVR Made Easy

Chapter 7 Troubleshooting

TeamViewer 9 Manual Wake-on-LAN

FAQ Communication over IE

Setting Up Your FTP Server

Movie Cube. User s Guide to Wireless Function

How To Industrial Networking

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

SATO Network Interface Card Configuration Instructions

Symphony Network Troubleshooting

Wireless G Broadband quick install

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Installation and Setup

For paid computer support call

DFL-210/260, DFL-800/860, DFL-1600/2500 How to setup IPSec VPN connection

CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC

How To Connect To An Egrabit With A Vpn On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Pv (For Mac) Or Ipv (Femalese) With An Ipv Or Ip

Ultra Thin Client TC-401 TC-402. Users s Guide

How to convert a wireless router to be a wireless. access point

Setting up VPN Access for Remote Diagnostics Support

How to setup PPTP VPN connection with DI-804HV or DI-808HV using Windows PPTP client

Chapter 6 Using Network Monitoring Tools

Quick Installation Guide. Overview. PLANET VIP-156/VIP-156PE/VIP-158 Quick Installation Guide

Chapter 2 Preparing Your Network

PIM31 Remote Setup and Operational Procedures

Getting Started with Remote Assistance

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

D-Link DAP-1360 Repeater Mode Configuration

Setting up VPN connection: DI-824VUP+ with Windows PPTP client

DDNS Management System User Manual V1.0

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

RADAR NETWORK SETUP WITH WINDOWS XP/VISTA

MaxSea TimeZero NN3D Radar Connection Checklist

Remote Access for Siemens S7-300 & 400 PLCs, and their VIPA equivalents S300 SPEED7.

NAPT. (SV8100 version 3.0 or higher)

Barak & Caldera Network Setup

ipad Installation and Setup

Configuring TheGreenBow VPN Client with a TP-LINK VPN Router

Basics of Port Forwarding on a Router for Security DVR s

STATIC IP SET UP GUIDE VERIZON 7500 WIRELESS ROUTER/MODEM

Part A:Background/Preparation

Networking Basics for Automation Engineers

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

Software installation and configuration IEC-line series

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Chapter 6 Virtual Private Networking

Device Installer User Guide

Configure VPN between ProSafe VPN Client Software and FVG318

Transcription:

Instructions. Setup of Teamviewer VPN for programming remotely With STEP7. Contents 1 Description... 2 2 Initial setup.... 3 2.1 Setup of remote PLC... 3 2.2 Setup of remote PC... 4 2.3 Setup of PG... 6 3 Connecting and use with STEP7.... 7 3.1 Connecting Teamviewer VPN.... 7 3.2 Connecting STEP7... 9 Page 1 05-12-2012 Page 1 of 10

1 Description Teamviewer is a software solution for remotely observing or controlling PCs. It is typically used for remote support from a suppliers home office to a customers remote location. By using the additional VPN functionality with Teamviewer, it is possible to reach out to further connected devices at the customers location. For example PLCs and operator panels. This guide describes how to program a Siemens S7 CPU remotely via Teamviewer VPN. Below is a general description of the setup: Programming PC (hereafter known as the PG ) at the location of the person that must access the PLC site remotely. The PG is connected to the internet, typically via the company office-lan. PC on the remote site (hereafter know as the remote PC ). The PC may be used for purposes related to the machine or process in connection with the PLC. For example the PC can be used for HMI software, or for database connection to the PLC. The HMI and/or database connection can continue to operate even during the remote access to the PLC via VPN. There will be two Ethernet network cards in the remote PC. The remote PC is connected to the machine or process LAN, via the first Ethernet card, with a fixed IP address. The remote PC is connected to the internet, via the second network card, typically connected to the company office-lan The PLC on the remote site (hereafter known as the remote PLC ) is connected to the machine or process LAN. Notice that this document does not describe the general installation or use of Teamviewer for remote monitoring or control of the remote PC. Notice that some of the screenshots in the document shows programs with a red title bar. This does not indicate an error, but is setup this way by the IT department of the company. Page 2 05-12-2012 Page 2 of 10

2 Initial setup. 2.1 Setup of remote PLC The remote PLC must be assigned addresses for IP, Subnet and Gateway that matches the strategy for IP addresses on all devices connected to the machine/process LAN. For example: Remote PLC IP: 192.168.1.131 Remote PLC Subnet: 255.255.255.0 Remote PLC Gateway (aka Router in STEP7): 192.168.1.132 Page 3 05-12-2012 Page 3 of 10

2.2 Setup of remote PC On the remote PC, the Ethernet adapter on the machine/process LAN must be assigned matching addresses for IP and Subnet: For example: Remote PC 1 st adapter IP: 192.168.1.132 Remote PC 1 st adapter Subnet: 255.255.255.0 Remote PC 1 st adapter Gateway (aka Router in STEP7): (none, not required for this purpose). On the remote PC, the second Ethernet adapter must have internet access. Typically it is connected to the customers LAN. For example: Remote PC 2 nd adapter IP: Specified via DHCP Remote PC 2 nd adapter Subnet: Specified via DHCP Remote PC 2 nd adapter Gateway: Specified via DHCP On the remote PC, Teamviewer must be installed, and the Teamviwer VPN driver must be installed. To install the Teamviewer VPN driver, start Teamviewer and go to the menu items Extras Options Advanced. Use the button Show advanced options, and go to Advanced network options Install VPN driver. On the remote PC, the registry has to be modified. Start the registry editor for example by Regedt32, and browse to HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters Set the parameter IPEnableRouter to 1. When done reboot the PC. Page 4 05-12-2012 Page 4 of 10

Open a command prompt, and type ipconfig /all Check that IP routing is enabled. Check that the Teamviewer VPN driver is running, and an IP address is assigned. Page 5 05-12-2012 Page 5 of 10

2.3 Setup of PG The PG must have internet access. Typically it is connected to the company LAN. On the PG, Teamviewer must be installed, and the Teamviwer VPN driver must be installed. To install the Teamviewer VPN driver, start Teamviewer and go to the menu items Extras Options Advanced. Use the button Show advanced options, and go to Advanced network options Install VPN driver. Page 6 05-12-2012 Page 6 of 10

3 Connecting and use with STEP7. 3.1 Connecting Teamviewer VPN. Start Teamviewer on the remote PC. Start Teamviewer on the PG. On the PG, in the Teamviewer start window, select the connection type VPN, and specify the Partner ID (typically informed by phone by a person on the remote site), then use the button Connect to partner. A password prompt will appear. Specify the password from the Teamviewer start window on the remote PC, (typically informed by phone by a person on the remote site). The VPN connection will now be established. A window appears on the PG with information about the connection. Make a note of the IP of Partner. Page 7 05-12-2012 Page 7 of 10

Add a route to the PLC on the PG: Open a command prompt on the PG, and type route add <IP of remote PLC> mask 255.255.255.255 <IP of Teamviewer VPN on remote PC> metric 1 for example: route add 192.168.1.132 mask 255.255.255.255 7.207.172.240 metric 1 <ENTER> Notice: The above route gives access to only the PLC by its specific IP address. To give access to several devices that have the same subnet, add the route like this: route add <base IP of remote devices> mask 255.255.255.0 <IP of Teamviewer VPN on remote PC> metric 1 for example: route add 192.168.1.0 mask 255.255.255.0 7.207.172.240 metric 1 <ENTER> This gives access to all the devices 192.168.1.1 192.168.1.255 on the remote network. Page 8 05-12-2012 Page 8 of 10

3.2 Connecting STEP7 On the PG, start STEP7. Go to the menu items Options Set PG/PC Interface. Set the access point S7ONLINE to Teamviewer VPN Adapter TCPIP. Page 9 05-12-2012 Page 9 of 10

Load the STEP7 project with the PLC that has to be reached. Test that there is a connection to the remote PLC. In Simatic Manager, select the CPU, and type CTRL-D. If OK, the online CPU properties will appear. It will be possible to access for example the diagnostics buffer of the CPU on the remote site. It is now possible to monitor and program the remote PLC. (end of document). Page 10 05-12-2012 Page 10 of 10