PRINCIPLE. REF 442635 (200 tests/cartridge) REF 476836 (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE



Similar documents
For In Vitro Diagnostic Use

Laboratory Procedure Manual

PRINCIPLE REF ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

This package insert contains information to run the Creatine Kinase assay on the ARCHITECT c Systems and the AEROSET System.

Creatine Kinase Microplate Assay Kit User Manual

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Creatine Kinase Assay Kit

How To Test For Creatinine

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

Laboratory Procedure Manual

Biochemistry Validation Form

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

This package insert contains information to run the Glucose assay on the ARCHITECT c Systems and the AEROSET System.

Vitamin B12. ADVIA Centaur System

ALKALINE PHOSPHATASE

Validation and Calibration. Definitions and Terminology

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Creatine Kinase Activity Assay Kit (Colorimetric)

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

SureStep Pro Linearity Test Kit and Analytical Measurement Range Verification (AMR)

Intact PTH. system. Intact PTH /R5. Key to symbols used 8K25

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

Med TechNet Online Services East Amherst, NY November 1997

RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit

This package insert contains information to run the Lactic Acid assay on the ARCHITECT c Systems and the AEROSET System.

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

CK-MB TEST CARD 004A302

Validation of measurement procedures

510(K) SUMMARY FEB Submitter: Name of the device: * Common Name: Clinical Chemistry Analyzer (with optional ISE Module) Attachment #2

Human Free Testosterone(F-TESTO) ELISA Kit

Reference Range: mmol/l (arterial) mmol/l (venous) CPT Code: 83605

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Basic Lessons in Laboratory Quality Control

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Tests that have had changes to the method/ CPT code, units of measurement, scope of analysis, reference comments, or specimen requirements.

A Sensitive Assay Method of Creatine Kinase-MB Isoenzyme in Human Serum Using Anti-CK-M Antiserum and Firefly Luciferase*

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Cold Agglutination Titer detecting Cold Reacting Antibodies

Calcium. Table 1: Difference between method means in percent

TOTAL PROTEIN FIBRINOGEN

MEDICAL DEVICE GUIDANCE

HIV Rapid Test Kits USAID Approval and Technical Guidance June 17, 2013 Revision

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

IgE (Human) ELISA Kit

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

HEMATOCRIT/HCT AND CALCULATED HEMOGLOBIN/HB

An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and

SMF Awareness Seminar 2014

Uscn Life Science Inc. Wuhan

for patient monitoring

Comparison of Glucose Determinations on Blood Samples Collected in Three Types of Tubes

Central Line Blood Draw

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

ab Free Testosterone ELISA Kit

Standardization, Calibration and Quality Control

Lab 2. Spectrophotometric Measurement of Glucose

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

ab Complement C1q Human ELISA Kit

Evaluation of Accuracy and User Performance of the TRUE METRIX Self-Monitoring Blood Glucose System *

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT

This package insert contains information to run the Uric Acid assay on the ARCHITECT c Systems and the AEROSET System.

Thrombin Generation Assay

MULTIPLE CHOICE QUESTIONS

Human Luteinizing Hormone (LH) Custom Kit

Contents. Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions...

How to Verify Performance Specifications

RealLine HCV PCR Qualitative - Uni-Format

UNIT: Total and Direct Bilirubin

Carcinoembryonic Antigen (CEA)

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company

Blood Glucose Monitoring: The Facts about Accuracy

Hydrogen Peroxide Cell-Based Assay Kit

FOR REFERENCE PURPOSES

Free Testosterone Cat# 2924Z

Creatine Kinase Fluorometric Assay Kit

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

This package insert contains information to run the Creatinine assay on the ARCHITECT c Systems and the AEROSET System.

LIAISON XL HBsAg Quant

Broad Selection of Antibodies & Antigens. for the Diagnostics Industry in North America

An Improved Method for the Determination of Creatine Kinase Activity in Serum

Cancer Antigen CA 125

UNIT: Enzymes II (Kinetic/Rate Reaction)

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

Overview of ISO for 'Biologicals'

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

Transcription:

SYNCHRON System(s) Chemistry Information Sheet Copyright 2010 Beckman Coulter, Inc. Creatine Kinase REF 442635 (200 tests/cartridge) REF 476836 (400 tests/cartridge) For In Vitro Diagnostic Use ANNUAL REVIEW Reviewed by: Date Reviewed by: Date PRINCIPLE INTENDED USE reagent, when used in conjunction with SYNCHRON LX System(s), UniCel DxC 600/800 System(s), is intended for the quantitative determination of creatine kinase activity in human serum or plasma. CLINICAL SIGNIFICANCE Measurements of creatine kinase and its isoenzymes are used in the diagnosis and treatment of myocardial infarction and muscle diseases such as progressive, Duchenne-type muscular dystrophy. METHODOLOGY reagent is used to measure the activity by an enzymatic rate method. 1,2,3,4 In the reaction creatine kinase catalyzes the transfer of a phosphate group from the creatine phosphate substrate to adenosine diphosphate (ADP). The subsequent formation of adenosine triphosphate (ATP) is measured through the use of two coupled reactions catalyzed by hexokinase (HK) and glucose-6-phosphate dehydrogenase (G6PDH) which results in the production of reduced β-nicotinamide adenine dinucleotide phosphate (NADPH) from β-nicotinamide adenine dinucleotide phosphate (NADP). The assay contains the activator monothioglycerol. The SYNCHRON System(s) automatically proportions the appropriate sample and reagent volumes into the cuvette. The ratio used is one part sample to 20 parts reagent. The system monitors the change in absorbance at 340 nanometers. This change in absorbance is directly proportional to the activity of in the sample and is used by the System to calculate and express activity. CHEMICAL REACTION SCHEME DECEMBER 2010 Page 1 of 10

SPECIMEN TYPE OF SPECIMEN Biological fluid samples should be collected in the same manner routinely used for any laboratory test. 5 Freshly drawn serum or plasma are the preferred specimens. Acceptable anticoagulants are listed in the PROCEDURAL NOTES section of this chemistry information sheet. Whole blood or urine are not recommended for use as a sample. SPECIMEN STORAGE AND STABILITY 1. Tubes of blood are to be kept closed at all times and in a vertical position. It is recommended that the serum or plasma be physically separated from contact with cells within two hours from the time of collection. 6 2. Stability of activity in sera is not well defined, but is generally poor. Specimens should be assayed as soon after collection as possible since activity loss may occur after specimens have been stored for 4 hours at room temperature, 8 to 12 hours refrigerated or 2 to 3 days when frozen. 6 Additional specimen storage and stability conditions as designated by this laboratory: SAMPLE VOLUME The optimum volume, when using a 0.5 ml sample cup, is 0.3 ml of sample. For optimum primary sample tube volumes and minimum volumes, refer to the Primary Tube Sample Template for your system. CRITERIA FOR UNACCEPTABLE SPECIMENS Refer to the PROCEDURAL NOTES section of this chemistry information sheet for information on unacceptable specimens. Criteria for sample rejection as designated by this laboratory: PATIENT PREPARATION Special instructions for patient preparation as designated by this laboratory: Page 2 of 10 DECEMBER 2010

SPECIMEN HANDLING Special instructions for specimen handling as designated by this laboratory: REAGENTS CONTENTS Each kit contains the following items: Two Creatine Kinase Reagent Cartridges (2 x 200 tests) or (2 x 400 tests and two bottles of [A-reagent]) VOLUMES PER TEST Sample Volume 13 µl ORDAC Sample Volume 3 µl Total Reagent Volume 260 µl Cartridge Volumes A 238 µl B 22 µl C REACTIVE INGREDIENTS REAGENT CONSTITUENTS Creatine phosphate Glucose ADP NAD + Hexokinase Glucose-6-phosphate dehydrogenase 53 mmol/l 18 mmol/l 2.9 mmol/l 2.4 mmol/l >11 KIU/L >3.8 KIU/L Also non-reactive chemicals necessary for optimal system performance. Avoid skin contact with reagent. Use water to wash reagent from skin. MATERIALS NEEDED BUT NOT SUPPLIED WITH REAGENT KIT At least two levels of control material Saline DECEMBER 2010 Page 3 of 10

REAGENT PREPARATION For P/N 442635 (200 tests): Transfer the entire contents of the smallest reagent compartment (C) into the largest reagent compartment (A). For P/N 476836 (400 tests): Transfer all the contents of one bottle (A-reagent) into the largest reagent compartment (A). Replace cartridge caps and gently invert the cartridge several times to ensure adequate mixing. ACCEPTABLE REAGENT PERFORMANCE The acceptability of a reagent is determined by ensuring that quality control results are within your facility s acceptance criteria. REAGENT STORAGE AND STABILITY reagent, when stored unopened at +2 C to +8 C, will remain stable until the expiration date printed on the cartridge label. Once prepared, the reagent cartridge is stable for 30 days at +2 C to +8 C unless the expiration date is exceeded. DO NOT FREEZE. Reagent storage location: CALIBRATION CALIBRATOR REQUIRED Calibration is not required. TRACEABILITY This measurand (analyte) is traceable to the manufacturer s selected Measurement Procedure as described in the Methodology section. QUALITY CONTROL At least two levels of control material, normal and abnormal, should be analyzed daily. In addition, these controls should be run with each new reagent cartridge and after specific maintenance or troubleshooting procedures as detailed in the appropriate system manual. More frequent use of controls or the use of additional controls is left to the discretion of the user based on good laboratory practices or laboratory accreditation requirements and applicable laws. The following controls should be prepared and used in accordance with the package inserts. Discrepant quality control results should be evaluated by your facility. Page 4 of 10 DECEMBER 2010

Table 1.0 Quality Control Material CONTROL NAME STORAGE TESTING PROCEDURE(S) 1. If necessary prepare reagent as defined in the Reagent Preparation section of this chemistry information sheet and load the reagent onto the system. 2. Program samples and controls for analysis. 3. After loading samples and controls onto the system, follow the protocols for system operations. For detailed testing procedures, refer to the SYNCHRON LX Operations Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual. CALCULATIONS The SYNCHRON System(s) performs all calculations internally to produce the final reported result. The system will calculate the final result for sample dilutions made by the operator when the dilution factor is entered into the system during sample programming. REPORTING RESULTS Equivalency between the SYNCHRON LX and UniCel DxC 600/800 Systems has been established. Chemistry results between these systems are in agreement and data from representative systems may be shown. REFERENCE INTERVALS Each laboratory should establish its own reference intervals based upon its patient population. The following reference intervals were taken from literature and a study performed on SYNCHRON Systems. 7 Table 2.0 Reference intervals Literature SYNCHRON INTERVALS CONVENTIONAL UNITS S.I. UNITS Serum or Plasma (Male) 38 174 IU/L 0.65 2.96 µkat/l Serum or Plasma (Female) 26 140 IU/L 0.46 2.38 µkat/l Serum or Plasma (Male) 49 397 IU/L 0.83 6.75 µkat/l Serum or Plasma (Female) 38 234 IU/L 0.65 3.98 µkat/l DECEMBER 2010 Page 5 of 10

INTERVALS CONVENTIONAL UNITS S.I. UNITS Laboratory Refer to References (8,9,10) for guidelines on establishing laboratory-specific reference intervals. Additional reporting information as designated by this laboratory: PROCEDURAL NOTES ANTICOAGULANT TEST RESULTS 1. If plasma is the sample of choice, the following anticoagulants were found to be compatible with this method based on a study of 20 healthy volunteers: Table 3.0 Acceptable Anticoagulants ANTICOAGULANT LEVEL TESTED FOR IN VITRO INTERFERENCE AVERAGE PLASMA-SERUM BIAS (IU/L) a Ammonium Heparin 29 Units/mL NSI b Sodium Heparin 29 Units/mL NSI Lithium Heparin 29 Units/mL NSI a Bias is based on worst case instead of average. b NSI = No Significant Interference (within ±10.0 IU/L or 7%). 2. The following anticoagulants were found to be incompatible with this method: Table 4.0 Incompatible Anticoagulants a ANTICOAGULANT Potassium Oxalate/Sodium Fluoride LEVEL TESTED FOR IN VITRO INTERFERENCE PLASMA-SERUM BIAS (IU/L) a 4.0 / 5.0 mg/ml -80.0 Sodium Citrate 6.6 mg/ml -97.0 LIMITATIONS None identified. Bias is based on worst case instead of average. Plus (+) or minus (-) signs in this column signify positive or negative bias. INTERFERENCES 1. The following substances were tested for interference with this methodology: Page 6 of 10 DECEMBER 2010

Table 5.0 Interferences a SUBSTANCE SOURCE LEVEL TESTED OBSERVED EFFECT b Bilirubin (unconjugated) Bovine 30 mg/dl NSI c Hemoglobin RBC hemolysate 50 mg/dl +12 IU/L Lipemia Intralipid d 500 mg/dl NSI Adenylate Kinase NA e 100 U/L +8 IU/L a Data shown was collected using SYNCHRON CX Systems. Equivalency between SYNCHRON LX Systems has been established by Deming regression analysis to SYNCHRON CX Systems. b Plus (+) or minus (-) signs in this column signify positive or negative interference. c NSI = No Significant Interference (within ± 10 IU/L or 7%). d Intralipid is a registered trademark of KabiVitrum, Inc., Clayton, NC 27250. e NA = Not applicable. 2. Refer to References (11,12,13) for other interferences caused by drugs, disease and preanalytical variables. PERFORMANCE CHARACTERISTICS ANALYTIC RANGE The SYNCHRON System(s) method for the determination of this analyte provides the following analytical ranges: Table 6.0 Analytical Range a CONVENTIONAL UNITS S.I. UNITS Serum or Plasma 5 1200 IU/L 0.1 20.0 µkat/l Serum or Plasma (ORDAC) a 860 4100 IU/L 14.3 68.3 µkat/l Overrange Detection and Correction. Refer to the SYNCHRON LX Operations Manual, or the UniCel DxC 600/800 System Instructions For Use (IFU) manual for more details on this function. Samples with activities exceeding the high end of the analytical range should be rerun with ORDAC enabled or diluted with saline and reanalyzed. REPORTABLE RANGE (AS DETERMINED ON SITE): Table 7.0 Reportable Range CONVENTIONAL UNITS S.I. UNITS SENSITIVITY Sensitivity is defined as the lowest measurable concentration which can be distinguished from zero with 95% confidence. Sensitivity for determination is 5 IU/L (0.08 µkat/l). EQUIVALENCY Equivalency was assessed by Deming regression analysis of patient samples to accepted clinical methods. DECEMBER 2010 Page 7 of 10

Serum or plasma (in the range of 10 to 1126 IU/L): Y (SYNCHRON LX Systems) = 1.025X + 0.39 N = 80 MEAN (SYNCHRON LX Systems) = 286.5 MEAN (SYNCHRON CX7 DELTA) = 279.1 CORRELATION COEFFICIENT (r) = 0.9991 Refer to References (14) for guidelines on performing equivalency testing. PRECISION A properly operating SYNCHRON System(s) should exhibit precision values less than or equal to the following: Table 8.0 Precision Values a b TYPE OF PRECISION Within-run Total IU/L 1 SD µkat/l CHANGEOVER VALUE a IU/L µkat/l % CV Serum/Plasma 5.0 0.08 142.9 2.29 3.5 Serum/Plasma (ORDAC) NA b NA NA NA 10.0 Serum/Plasma 7.5 0.12 142.9 2.29 5.3 Serum/Plasma (ORDAC) NA NA NA NA 15.0 When the mean of the test precision data is less than or equal to the changeover value, compare the test SD to the SD guideline given above to determine the acceptability of the precision testing. When the mean of the test precision data is greater than the changeover value, compare the test % CV to the guideline given above to determine acceptability. Changeover value = (SD guideline/cv guideline) x 100. NA = Not applicable. Refer to References (15) for guidelines on performing precision testing. Comparative performance data for a SYNCHRON LX System evaluated using the NCCLS Proposed Guideline EP5-T2 appears in the table below. 15 Each laboratory should characterize their own instrument performance for comparison purposes. Table 9.0 NCCLS EP5-T2 Precision Estimate Method a TYPE OF IMPRECISION Within-run Total No. Systems No. Data Points a Test Mean Value (IU/L) EP5-T2 Calculated Point Estimates SD %CV Serum Control 1 1 80 52.3 1.6 3.0 Serum Control 2 1 80 630.0 4.8 0.8 Serum Human Pool 1 80 258.2 2.9 1.1 Serum Control 1 1 80 52.3 1.9 3.7 Serum Control 2 1 80 630.0 5.7 0.9 Serum Human Pool 1 80 258.2 3.4 1.3 The point estimate is based on the data from one system, run for twenty days, two runs per day, two observations per run on an instrument operated and maintained according to the manufacturer s instructions. Page 8 of 10 DECEMBER 2010

NOTICE These degrees of precision and equivalency were obtained in typical testing procedures on a SYNCHRON LX System and are not intended to represent the performance specifications for this reagent. ADDITIONAL INFORMATION For more detailed information on SYNCHRON LX Systems or UniCel DxC Systems, refer to the appropriate system manual. SHIPPING DAMAGE If damaged product is received, notify your Beckman Coulter Clinical Support Center. DECEMBER 2010 Page 9 of 10

REFERENCES 1. Oliver, J. T., Biochem. J., 61:116 (1955). 2. Neilsen, L., Ludvigsen, B, J. Lab. Clin. Med., 62:159 (1963). 3. Rosalki, S. B., J. Lab. Clin. Med., 69:696 (1967). 4. Stow, R. W., Randall, B. F., Am. J. Physiol., 179:678 (1954). 5. Tietz, N. W., "Specimen Collection and Processing; Sources of Biological Variation", Textbook of Clinical Chemistry, 2nd Edition, W. B. Saunders, Philadelphia, PA (1994). 6. National Committee for Clinical Laboratory Standards, Procedures for the Handling and Processing of Blood Specimens, Approved Guideline, NCCLS publication H18-A, Villanova, PA (1990). 7. Tietz, N. W., Clinical Guide to Laboratory Tests, 3rd Edition, W. B. Saunders, Philadelphia, PA (1995). 8. National Committee for Clinical Laboratory Standards, How to Define, Determine, and Utilize Reference Intervals in the Clinical Laboratory, Approved Guideline, NCCLS publication C28-A, Villanova, PA (1994). 9. Tietz, N. W., ed., Fundamentals of Clinical Chemistry, 3rd Edition, W. B. Saunders, Philadelphia, PA (1987). 10. Henry, J. B., Clinical Diagnosis and Management by Laboratory Methods, 18th Edition, W. B. Saunders Company, Philadelphia, PA (1991). 11. Young, D. S., Effects of Drugs on Clinical Laboratory Tests, 4th Edition, AACC Press, Washington, D. C. (1995). 12. Friedman, R. B., Young, D. S.,Effects of Disease on Clinical Laboratory Tests, 3rd Edition, AACC Press, Washington, D.C. (1997). 13. Young, D. S., Effects of Preanalytical Variables on Clinical Laboratory Tests, 2nd Edition, AACC Press, Washington, D. C. (1997). 14. National Committee for Clinical Laboratory Standards, Method Comparison and Bias Estimation Using Patient Samples, Approved Guideline, NCCLS publication EP9-A, Villanova, PA (1995). 15. National Committee for Clinical Laboratory Standards, Precision Performance of Clinical Chemistry Devices, Tentative Guideline, 2nd Edition, NCCLS publication EP5-T2, Villanova, PA (1992). Beckman Coulter Ireland, Inc., Mervue Business Park, Mervue, Galway, Ireland 353 91 774068 Beckman Coulter, Inc., 250 S. Kraemer Blvd., Brea, CA 92821 Page 10 of 10 DECEMBER 2010