General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

AuditMatic Enterprise Edition Installation Specifications

General Specifications

General Specifications

WEB COMPAS MINIMUM HOSTING REQUIREMENTS

MedInformatix System Requirements

Ignify ecommerce. Item Requirements Notes

Sage Grant Management System Requirements

1 HARDWARE AND SOFTWARE REQUIREMENTS FOR HAL E-BANK SYSTEM

Best Practices & Deployment SurfControl Mobile Filter v

Grant Management. System Requirements

Enterprise Edition. Hardware Requirements

System Requirements. SuccessMaker 5

General Specifications

Install Guide Housatonic Project Plan for Web. Housatonic Software - Project Plan 365 App

System Requirements for Microsoft Dynamics GP 9.0

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

System Requirements for Microsoft Dynamics GP 2013

Abila Grant Management. System Requirements

Minimum Management Requirements

Cormant-CS System Requirements

Hardware Requirements

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

Delphi 2015 SP1-AP1 System Requirements


Sage CRM Technical Specification


msuite5 & mdesign Installation Prerequisites

Supported Platforms May 2013

Oracle Insurance General Agent Hardware and Software Requirements. Version 8.0

Microsoft Office 2010 system requirements

Worry-FreeTM. Business Security Standard and Advanced Editions. System Requirements. Administrator s Guide. Securing Your Journey to the Cloud8

Minimum System Requirements

Minimum Software and Hardware Requirements

Terminal Services for InTouch 7.1/7.11. Terminal Services for InTouch 7.1/7.11 PRODUCT POSITION PRODUCT DATASHEET

System Requirements. Maximizer CRM Enterprise Edition System Requirements

System Requirements for Microsoft Dynamics GP 2015

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

The Education Edge / The Financial Edge 7.85

Running FileMaker Pro 5.0v3 on Windows 2000 Terminal Services

Product Life Cycle Management

RightNow November 09 Workstation Specifications

CBE system requirements

Delphi+ System Requirements

CCC Technical Requirements. Revised July 2014

WINSCRIBE HARDWARE SPECIFICATIONS

Symantec Backup Exec.cloud

Intel Pentium IV or compatible 1 gigahertz (GHz) or higher processor

Enterprise Planning Large Scale ARGUS Enterprise /29/2015 ARGUS Software An Altus Group Company

Professional and Enterprise Edition. Hardware Requirements

Priority Zoom v17: Hardware and Supporting Systems

Synergis Software 18 South 5 TH Street, Suite 100 Quakertown, PA , version

Enterprise Edition Technology Overview

Installation Prerequisites for MetaFrame Presentation Server 3.0

RSA AUTHENTICATION AGENTS FOR MICROSOFT WINDOWS

Microsoft Office Outlook 2010: Level 1

Plant Messenger Alert Reporting Service

QHR Accuro EMR IT Hardware Requirements

PROTECTION SERVICE FOR BUSINESS WELCOME TO THE BUSINESS OF FREEDOM

CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS

Streamlining Case Management Workflow

ThinPrint.print Server Engine installation and architecture

Propalms TSE Deployment Guide

Blackbaud Hosting Services

General Specifications

System requirements for MuseumPlus and emuseumplus

ELECTRONIC QUALITY MANAGEMENT SOFTWARE

Determining Your Computer Resources

Minimum Computer System Requirements

Sage MAS 200 ERP Level 3.71 Version 4.30 Supported Platform Matrix

Sage 100 Standard ERP Version 2013 Supported Platform Matrix Created as of November 21, 2013

Technology Partners. Acceleratio Ltd. is a software development company based in Zagreb, Croatia, founded in 2009.

Microsoft Office Outlook 2013: Part 1

Version 3.8. Installation Guide

System Requirements for Microsoft Dynamics GP 10.0

Hardware & Software Requirements for BID2WIN Estimating & Bidding, the BUILD2WIN Product Suite, and BID2WIN Management Reporting

System Requirements for TaxWise November 21, 2011

System Requirements Version 8.0 July 25, 2013

AXIS Camera Station Quick Installation Guide

inforouter V8.0 Server & Client Requirements

To ensure you have the appropriate equipment and settings please review the following: Software and Hardware Recommendations.

CCC Technical Requirements. Updated: June 2016

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

Step-by-Step Guide to Setup Instant Messaging (IM) Workspace Datasheet

Technical Information

System Requirements. SuccessMaker 5 Hosted

Remote Deposit Capture Installation Guide

Pipeline Compliance System v7.6. Installation Guide

Revit products will use multiple cores for many tasks, using up to 16 cores for nearphotorealistic

System Requirements for Web Applications

Autodesk Building Design Suite 2012 Standard Edition System Requirements... 2

FileMaker. Running FileMaker Pro 7 on Windows Server 2003 Terminal Services

Transcription:

General Specifications GS 33Q02N81-31E LPC7800 VTSPortal Basic Pack LPC7801 VTSPortal Multiple Client Builder License GENERAL The primary objective of the Yokogawa Versatile Terminal Service Application Portal (VTSPortalTM) enables you to put CENTUM CS 3000, Exaplog, Exapilot, Exaquantum, and PRM on the web site via the Windows terminal service. VTSPortal is to provide an integrated Human-Machine Interface (HMI) framework that promotes the idea of digital independence for all Yokogawa solutions. Digital independence is the ability to connect to any Yokogawa HMI application, over any network connection. The VTSPortal are for operational staff, engineering staff, and plant management staff in new or existing plants that deploy a mixture of Yokogawa products and who now wish to extend the reach of those applications to support remote or web access. Access is provided in the form of a Portal Web Site with customizable content on a per-user basis. Potential Features Support remote maintenance or engineering work for CS 3000 installations via a dialup or other WAN connection. Support remote monitoring and operation for unmanned control areas. Support connection of mobile field devices to a control room server for CS 3000 installations. Support an aggregated access point for all applications. Support application deployment on dedicated thin-client hardware. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 GS 33Q02N81-31E Copyright Jul. 2005 5th Edition Oct. 22, 2007

2 VTSPotal SYSTEM ARCHITECTURE The VTSPortal can be deployed in an internal LAN environment (e.g. intranet), a WAN environment with remote access capabilities (e.g. internet), or in a mixture that provides both LAN and WAN access. WAN Portal Clients Laptop PDA Desktop PDA Remote Engineering Station Modem Internet Portal Clients W-LAN Tablet W-LAN Portal Clients Firewall W-LAN Laptop Office Network W-LAN Access Point Modem VTSPortal Web Server Plant Network Exapilot Server VTSPortal Application Server (Exapilot) VTSPortal Application Server (LHS1150/LHM1150) CS 3000 HIS Control Network Figure VTSPortal Network Architecture Portal Client is a station providing client access to the VTSPortal Application Server. A client can connect to the Server via an Ethernet based Local Area Network (LAN), Wireless LAN (W-LAN), or Wide Area Network (WAN). VTSPortal Web Server is the station hosting the portal web site and providing Web browser based access to the published applications on the VTSPortal Application Servers. The VTSPortal Application Server is a PC that provides HMI of applications for the VTSPortal Web server by using the Windows terminal service. Install the Windows terminal service, each product package, and the VTSPortal Application Server Function on the PC (Hereinafter, this PC is referred to as an application server). In the figure above, the application server for CENTUM CS 3000 and the application server for Exapilot are prepared respectively. To provide the Operation and Monitoring Function of CENTUM CS 3000 for the VTSPortal client, the Server for Remote Operation and Monitoring Function (LHS1150/LHM1150) is required for the application server. The VTSPortal Web Server Function and the Application Server Function cannot be installed on one PC. Please prepare a PC for the VTSPortal Web server and a PC for the application server respectively. When the Multiple Client Builder License is installed on the application server, you can run several builder functions simultaneously. F01E.ai GS 33Q02N81-31E Jan. 1, 2006-00

3 In the LAN deployment (see figure below), the Portal Web Server and Application Server components are installed and connected to the existing Plant LAN. If needed, a firewall should added to isolate the connection between the Plant LAN and an Office LAN, thus providing portal access to the computers outside the Plant LAN. Wireless LAN (W- LAN) access to the portal can be added by installing the appropriate Wireless Access Points to the Office LAN and/or Plant LAN segments. Desktop PC Laptop computer Wireless Access Point Wireless Laptop Office LAN Network Terminal Wireless Access Point Firewall Portable device Plant LAN Control network DCS Station VTSPortal Application Server VTSPortal Web Server Figure VTSPortal System Architecture for LAN deployment F02E.ai GS 33Q02N81-31E Jul. 15, 2005-00

4 In the WAN deployment (see figure below), the Application Server component is installed and connected to the existing Plant LAN. To provide an isolated and secure Internet connection between the Application Server and the Web clients, the Portal Web Server is installed in a demilitarized zone (DMZ). A DMZ is a separate network segment between the external and internal firewalls that is not directly connected to either the internal LAN or the Internet. Internet Fierwall #1 (Internet Edge Fierwall) VTSPortal Web Server Plant LAN Fierwall #2 (Fierwall for control system) DCS Station Application Server Control network Figure VTSPortal System Architecture for LAN deployment F03E.ai GS 33Q02N81-31E Jul. 15, 2005-00

5 FUNCTIONAL OVERVIEW Portal Client PC Web Browser RDP Client VTSPortal Web Server PC IIS Portal Site Application Publishing DB Terminal Service TSE App App Application Manager CS 3000 Search Service CS 3000 DB VTSPortal Application Server PC Figure Functional Overview Web Browser is the client program used to navigate the portal web site. Either a standard web browser (e.g. Internet Explorer) or the secure browser (VTSExplorer) provided with the portal software can be used for this purpose. RDP Client is the Terminal Services Client provided by Microsoft to execute Remote Desktop Connections. This client is freely available for use on any 32-bit Windows O/S and is pre-installed on all Windows XP and.net PCs Portal Site is the collection of prepared web pages, data stores, and template files used to support the web access to the terminal service applications. Application Manager is the administration tool used on each Application Server to selectively publish the installed applications to the Portal Users. CS 3000 Search Service is the search engine web service used to find matching results for CS 3000 HIS/ENG applications. TSE App/App are the HIS Terminal Service Enabled (TSE) applications or other applications that have been installed within Terminal Services and published for portal user access. Terminal Services is the configurable service included in the Windows Server 2003 operating system that gives it the capability to run 32-bit Windows-based applications centrally from a server. F04E.ai GS 33Q02N81-31E Jan. 1, 2006-00

6 FUNCTIONAL SPECIFICATIONS Supported Products and Applications CENTUM CS 3000 (R3.05 or later, R3.06.10 or later when installed in Windows Server 2003 SP1) Operation Application Engineering Application Exapilot (R3.30 or later) Exapilot client Exaplog (R3.02 or later) Exaplog client Exaquantum Process Information Management Systems (PIMS) (R2.20 or later) Exaquantum client Plant Resource Manager (R2.10 or later, R2.20 or later when installed in Windows Server 2003 SP1) PRM Client OPERATING ENVIRONMENT Hardware Requirements Item VTSPortal Web Server VTSPortal Application Server Processor 1.8 GHz or faster Pentium class PC for Server with 2.4 GHz or faster Pentium-class processors Memory 512 MB RAM minimum 1024 MB RAM recommended. 1024 MB RAM minimum. Disk 1.5 to 4 GB hard drive space 10 GB or greater hard drive; NTFS partitions Network High performance Ethernet NICs High performance Ethernet NIC; VI701 Control Bus Interface Card (Yokogawa) required when connecting to CS 3000 platform.(*1) *1: In case of V net, VF701 is required instead of VI701. GS 33Q02N81-31E Apr. 1, 2006-00

7 Software Requirements OS Item VTSPortal Web Server Application Server VTSPortal Client Windows Server 2003 Web Edition SP1, SP2, R2, R2 SP2 or with no SP, Windows Server 2003 Standard Edition SP1, SP2, R2, R2 SP2 or with no SP Windows Server 2003 (Standard Edition SP1, SP2, R2, R2 SP2 or with no SP);Terminal Services enabled (*1) Windows 2000 Professional, Windows XP Professional Web Server Microsoft IIS v6.0 (*3) Microsoft IIS v6.0 (*2, *3) Browser Microsoft Internet Explorer 6.0 or VTSExplorer (*4) Terminal Service Client Database Each Application SQL Server or Microsoft SQL Server Desktop Engine (MSDE) (*6) SQL Server or Microsoft SQL Server Desktop Engine (MSDE) (*2, *6) Exapilot, Exaplog, Exaquantum, PRM, CS 3000 Operation function or CS 3000 Engineering function (*7,*8) Microsoft Terminal Services Client (version 2600 and newer, 5.1.2600. x) (*5) *1: Use terminal service function. TSE-CAL (Client Access License) as well as normal CAL of Windows Server 2003 is required to use the terminal service. *2: The Web server and the database are required only when CS 3000 Search Service is used. *3: IIS is software that comes with Windows Server 2003. *4: VTSExplorer is software supplied with VTSPortal. VTSExplorer must be installed even though the Microsoft Internet Explorer 6.0 is used. Moreover,.NET Framework 1.1 is required for installing the VTSExplorer. *5: The Microsoft Terminal Service Client is preinstalled on Windows XP Professional. It can be installed with the installation media of Windows Server 2003 for free when Windows 2000 Professional is used. *6: The Microsoft SQL Server is commercial software for sale. It is required to purchase this software separately to use the Microsoft SQL Server. The Microsoft SQL Server Desktop Engine (MSDE) is a database software supplied by Microsoft for free. It is bundled with the VTSPortal installation media. It is not required to purchase software separately. *7: Using the CS 3000 Search Service requires engineering functions of CS 3000. *8: A license of each application is not included in the license of the VTSPortal software. Purchase the required software licenses separately. Note for Executing Each Application The software requirements of the VTSPortal application server are required to meet the software requirements of each installed application. For the software requirements of each application, please refer to GS of each application. For Exaplog, Exapilot, and the plant resource manager, the PC on which the server function and the client function are installed can be used as an application server. For Exaquantum, the PC on which only the client function is installed can be used as an application server; the PC on which the server function and the client function are installed cannot be used. On the VTSPortal application server, FDA:21 CFR Part 11 compliant package (LHS5170) cannot be used. On FDA:21 CFR Part 11 compliant system, do not publish the Builder Function and the Recipe Management Function. When the application of CENTUM CS 3000 is published, it is required to install the Standard Operation and Monitoring Function and the Server for Remote Operation and Monitoring Function. The Server for Remote Operation and Monitoring Function is used for publishing the software of the Operation and Monitoring Function of CS 3000. Therefore, the Operation and Monitoring Option Function not supported by the Server for Remote Operation and Monitoring Function is not supported also by VTSPortal. For the Operation and Monitoring Option Function supported by the Server for Remote Operation and Monitoring Function, refer to GS 33Q02L60-31E LHS1150, LHM1150 Server for Remote Operation and Monitoring Function. GS 33Q02N81-31E Oct. 22, 2007-00

8 MODEL AND SUFFIX CODE VTSPortal Basic Pack (for New Installation) Description Model LPC7800 VTSPortal Basic Pack [Media model LPCAM80-C11] -S Basic software license -C Multiple software license (for 2 or more) Suffix Codes 1 Always 1 1 English version Option Codes /N The number of additional clients Note: The Web server license, the application server license, the application manager license, and the 10 client connection license are included in this package. Note: Please specify the number of excess clients by the Option Code when connected clients exceed 10 in ordering newly. Note: The number of clients might be restricted by the application side. Note: This package does not require the system ID license. VTSPortal Basic Pack (for Addition) Description Model LPC7800 VTSPortal Basic Pack [Media model LPCAM80-C11] -A Software License for additional clients Suffix Codes 1 Always 1 1 English version Option Codes /N The number of additional clients Note: Please specify the number of clients by the Option Code when connected clients are increased. Note: When the number of clients is restricted by the application side, add the client licenses on the application side if required. Note: This package does not require the system ID license. VTSPortal Multiple Client Builder License Description Model LPC7801 VTSPortal Multiple Client Builder License [Media model LPCAM80-C11] -S Basic software license -C Multiple software license (for 2 or more) Suffix Codes 1 Always 1 1 English version Note: This package does not require the system ID license. Software Media for VTSPortal Model LPCAM80 Software Media for VTSPortal -C Supplied media: CD-ROM Suffix Codes 1 Always 1 1 English version Description Note: Electronic Instruction Manual is included in this media. Note: No license is required to use the electronic instruction manual media. ORDERING INFORMATION Specify the model and suffix codes. TRADEMARKS CENTUM and VTSPortal are registered trademarks of Yokogawa Electric Corporation. Microsoft, Windows, Windows 2000 and Windows Sever 2003 are registered trademark of Microsoft Corporation in the United States and/or other countries. Adobe, Acrobat and Acrobat Reader are registered trademarks of Adobe Systems Incorporated. Ethernet is a registered trademark of XEROX Corporation in the United States and/or other countries. Other product and company names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. GS 33Q02N81-31E Jun. 1, 2007-00