Analysis of Trajectory Log Files of TrueBeam Medical Electron Linear Accelerator for Patient Specific IMRT QA



Similar documents
Post Treatment Log File Based QA Varian. Krishni Wijesooriya, PhD University of Virginia. D e p a r t m e n t of R a d i a t i o n O n c o l o g y

QA of intensity-modulated beams using dynamic MLC log files

ELECTRONIC MEDICAL RECORDS (EMR) STREAMLINE CH I PROCESS. Ping Xia, Ph.D. Head of Medical Physics Department of Radiation Oncology Cleveland Clinic

Follow this and additional works at:

RapidArc QA Program in Prince of Wales Hospital. Michael L. M. Cheung, Physicist Prince of Wales Hospital Hong Kong

Correlation of phantom-based and log file patient-specific QA with complexity scores for VMAT

MLC Characteristics. Treatment Delivery Systems 2 Field Shaping; Design Characteristics and Dosimetry Issues. Presentation Outline

Performance evaluation and quality assurance of Varian enhanced dynamic wedges

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

QA & DOSIMETRY NEWS. Respiratory MotionSim TM. Introducing. Quality Reports [EMR] Plan Quality Management»

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Medical Device Correction

Quality Assurance of accelerators; the technologists responsibility

Automated Analysis of Varian Log Files for Advanced Radiotherapy Treatment Verification: A Multicenter Study

Clinical Photon Beams

Challenges in small field MV photon dosimetry

1. Provide clinical training in radiation oncology physics within a structured clinical environment.

RADIATION THERAPY. Dosimetry Pioneers since 1922 NEW

Independent corroboration of monitor unit calculations performed by a 3D computerized planning system

First Three Years After Project Proton Therapy Facility:

NIA RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Quality Assurance of Radiotherapy Equipment

Evaluation of complexity and deliverability of IMRT- treatment plans. Author: Elin Svensson Supervisors: Anna Bäck and Anna Karlsson Hauer

Key words: treatment planning, quality assurance, 3D treatment planning

Our Department: structure and organization

External dosimetry Dosimetry in new radiotherapeutic techniques

Secondary Neutrons in Proton and Ion Therapy

Specifications Varian Treatment Streamlined Treatment Delivery Management Application. Specifications

SEAAPM Symposium The Practice of Quality Assurance in an Era of Change

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

Worldwide Quality Assurance networks for radiotherapy dosimetry

Accreditation Is Coming

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

Clinical Study Monte Carlo-Based Dose Calculation in Postprostatectomy Image-Guided Intensity Modulated Radiotherapy: A Pilot Study

VOLUMETRIC INTENSITY-MODULATED ARC THERAPY VS. CONVENTIONAL IMRT IN HEAD-AND-NECK CANCER: A COMPARATIVE PLANNING AND DOSIMETRIC STUDY

Prostate IMRT: Promises and Problems Chandra Burman, Ph.D. Memorial Sloan-Kettering Cancer Center, New York, NY 10021

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

Department of Radiation Oncology

Albany Medical Center Chief Medical Physicist Radiation Oncology Imaging and Related Services

Chapter 12 QUALITY ASSURANCE OF EXTERNAL BEAM RADIOTHERAPY

THE DOSIMETRIC EFFECTS OF

IAEA-TECDOC Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems

The Medical Physicist as Computer Geek: Custom Software in the Clinic

QUALITY ASSURANCE OF TREATMENT PLANNING SYSTEMS PRACTICAL EXAMPLES FOR NON-IMRT PHOTON BEAMS

Intensity-Modulated Radiation Therapy (IMRT)

Quality Reports With. PlanIQ. *Export only. 510(k) pending. Patent pending. Your Most Valuable QA and Dosimetry Tools

TRAINING PROGRAMMES IN RADIATION SAFETY CONDUCTED BY RADIOLOGICAL PHYSICS & ADVISORY DIVISION

PROFORMA ACCEPTANCE / QUALITY ASSURANCE TESTS OF REMOTE AFTERLOADING BRACHYTHERAPY UNIT

Calculation of Contra-lateral Lung Doses in Thoracic IMRT: An Experimental Evaluation

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

Digital vs. Analogue Control Systems

The Therac 25 A case study in safety failure. Therac 25 Background

Gated Radiotherapy for Lung Cancer

Volumetric modulated arc therapy (VMAT) for prostate cancer

IBA Proton Therapy. Biomed days Vincent Bossier. System Architect Protect, Enhance and Save Lives

Clinical Education A comprehensive and specific training program. carry out effective treatments from day one

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

RISK OF SECONDARY MALIGNANT NEOPLASMS FROM PROTON THERAPY AND INTENSITY-MODULATED X-RAY THERAPY FOR EARLY-STAGE PROSTATE CANCER

An Integer Programming Approach to Conversion from Static to Continuous Delivery of Intensity Modulated Radiation Therapy

Acknowledgement. Prerequisites: Basic Concepts of IMRT. Overview. Therapy Continuing Education Course Clinical Implementation of IMRT for Lung Cancers

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients

Medical Physicist Courses in India

The validation of a tumour control probability (TCP) model for supporting radiotherapy treatment planning.

Manual for simulation of EB processing. Software ModeRTL

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Virtual Reality Training for Radiotherapy becomes a Reality

MEDICAL DOSIMETRY. COLLEGE OF APPLIED SCIENCES AND ARTS Graduate Faculty: therapy.

7/21/2014. Quality Metrics and Risk Management with High Risk Radiation Oncology Procedures. Disclosure of Conflict of Interest

Radiation Oncology Centers Participating in MassHealth. Daniel Tsai, Assistant Secretary and Director of MassHealth

I C 5 5l v ri 510(K) SUMMARY. Prowess Panther

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Establishing a Patient Safety Program in Radiation Oncology

Scripps Proton Therapy Center: Configuration and Implementation

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Quality Assurance in Stereotactic. Radiotherapy

Hands-on course Quality Assurance of Advanced Radiation Therapy

MSBS/Medical Physics Clinical Radiation Oncology Degree Requirements

Department of Radiation Oncology H. Lee Moffitt Cancer Center Khosrow Javedan M.S, Craig Stevens MD, Ph.D., Ken Forster Ph.D.

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

Multi-Channel Radiochromic Film Dosimetry. Adapted from A.Micke Spain, April 2014

There must be an appropriate administrative structure for each residency program.

World-first Proton Pencil Beam Scanning System with FDA Clearance

Gamma Knife and Axesse Radiosurgery

BARC DEVELOPS COBALT-60 TELETHERAPY MACHINE FOR CANCER TREATMENT

INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR PROSTATE CANCER PATIENTS

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

Transit Dosimetry for Patient Treatment Verification with an Electronic Portal Imaging Device. Sean L Berry

Quality Assurance of Advanced Radiation Therapy Hands-on course

Quality Assurance for Treatment Planning Systems

Evaluation of an automated knowledge based treatment planning system for head and neck

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

Intensity-modulated radiotherapy and volumetric-modulated arc therapy for malignant pleural mesothelioma after extrapleural pleuropneumonectomy

REPORT ORGANIZATION ABSTRACT I. INTRODUCTION CALCULATION OF EFFECTIVE DOSE PER IMAGE ACQUISITION CALCULATION OF EFFECTIVE DOSE PER TREATMENT COURSE

Transcription:

Cancer Research and Oncology: Open Access Received: Nov 16, 2015, Accepted: Jan 12, 2016, Published: Jan 15, 2016 CancerResOncol, Volume 1, Issue 1 http://crescopublications.org/pdf/crooa/crooa-1-001.pdf Article Number: CROOA-1-001 Editorial Open Access Analysis of Trajectory Log Files of TrueBeam Medical Electron Linear Accelerator for Patient Specific IMRT QA Rajesh Kumar* and SD Sharma Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai-400094, India *Corresponding Author: Dr. Rajesh Kumar, Radiological Physics &Advisory Division, Bhabha Atomic Research Centre, CTCRS Building, Anushaktinagar, Mumbai-400085, India, E-mail: rajresh@gmail.com Citation:Rajesh Kumar and SD Sharma (2016) Analysis of Trajectory Log Files of True Beam Medical Electron Linear Accelerator for Patient Specific IMRT QA. CancerResOncol 1: 001. Copyright: 2016 Rajesh Kumar and SD Sharma. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted Access, usage, distribution, and reproduction in any medium, provided the original author and source are credited. Abstract Aim: To demonstrate trajectory log files of TrueBeam medical electron linear accelerator as patient specific IMRT QA tools. Materials and Methods: Twenty six IMRT fields treated using Truebeam medical electron linear accelerator (LINAC) comprising different clinical cases were selected and analysed using software tools were developed to: (i) extract useful information from the trajectory log binary file of Truebeam accelerator, (ii) compare leaf positions derived from trajectory log data,(iii) calculate fluence from the expected and actual leaves positions, and (iv) plot the error histogram from the expected and actual fluence, for patient specific QA. Results: The percentage error in fluence calculated from expected and actual leaves positions are almost negligible. In all the cases studied, median and mode of percentage errors are zero while mean ranges from -0.01 to 0.003. Minimum and maximum values of percentage error are in range of -1.1 to 1.04. Conclusions: Software tools were developed to analyse the MLC Log files of True beam LINAC as patient specific QA in IMRT. The based fluence map estimated through log files analysis shows that the dose delivered to the patient by the Truebeam LINAC is highly accurate. This tool can be used as patient specific IMRT QA for other medical LINAC as well. Keywords: IMRT; Trajectory log file; Patient Specific IMRT QA. Introduction Intensity modulated radiotherapy (IMRT) is a complex radiotherapy process and demand stringent quality assurance (QA) process for whole chain of radiotherapy process [1-6]. Especially pre-treatment dose verification commonly known as patient specific dosimetry QA is carried out by almost all the IMRT practicing radiotherapy centre [7]. QA process for IMRT implementation in clinical practice can be divided in three groups: (1) Commissioning of the IMRT system which includes planning system (TPS) parameter adjustment, dosimetric tests with different phantoms, adjustment of the delivery system and tests of the data transfer; (2) Regular machine related quality assurance procedures which comprise mechanical precision of static test fields or mechanical and dosimetric precision of dynamic test fields; and (3) Regular patient related quality assurance procedures which involve dosimetric plan verification, dosimetric field by field verification and independent monitor unit (MU) checks. 2016 Rajesh Kumar and SD Sharma. Volume 1 Issue 1 CROOA-1-001 Page 1 of 5

First two QA programs are standard in nature and must be followed for beam delivery devices even without IMRT/ volumetrically modulated radiotherapy (VMAT) capabilities. The most common IMRT error includes error in calibration or commissioning of treatment planning and delivery system, wrong field data transfer etc. In an ideal situation, TPS used for IMRT are designed and commissioned to accurately simulate the beam delivery system; Machine QA programme for MLC calibration and known mechanical problems for each MLC and delivery type and Patient-specific QA focuses on potential clinical errors. To avoid patient specific potential clinical error, measurement based patient specific IMRT QA is performed [8-13]. It is performed only for limited number of times and requires considerable time of delivery system as well as of medical physicist. However, patient specific clinical errors can occur at any time during the course of treatment. If the treatment planning system has been commissioned suitably for IMRT and adequate periodic machine QA for IMRT are in place, measurement based patient specific IMRT QA can be replaced with software based IMRT QA for some radiotherapy equipments. Trajectory log file which is `free information and can be harvested for purposes of documenting individual patient treatments. Data in log files does not require any additional time or dose for the patient. Data in log file can be analysed off-line for IMRT QA purposes. Log file data have been explored for QA by a number of researchers [14-17]. However limited information is available on the TrueBeam trajectory log file generated fluence map based IMRT QA. This paper describes the method of IMRT QA by comparing the fluence calculated from expected leaves positions and actual leaves positions derived from trajectory log file. A complete file description may be found elsewhere [18]. In this study, software tools were developed to: (i) Extract useful information from the trajectory log binary file of Truebeam accelerator, (ii) Compare leaf positions derived from trajectory log data, (iii) Calculate fluence from the expected and actual leaves positions, and (iv) Plot the error histogram from the expected and actual fluence. Twenty six IMRT fields treated using Truebeam medical electron linear accelerator (LINAC) comprising different clinical cases were selected and analysed using above mentioned tools for patient specific QA. Results and Discussion Figure 1 shows the fluence map derived from the expected leaves positions while Figure 2 presents the fluence map derived from actual leaves position recorded in trajectory log file of an IMRT treatment field. Materials and Methods The QA studies were performed using Trajectory Log file generated by Truebeam medical electron linear accelerator (Varian Medical Systems, Palo Alto, California). Truebeam control system generates a trajectory log file which records the actual axis position and delivers MUs at periodic intervals of 20 ms along with their expected values. The system is configured to record 60,000 data sets for a period of 20 minutes at an interval of 20 ms. The trajectory log file stores data in a binary format which needs to be converted into a readable format for intended application. A single binary file generated includes information about expected and actual values of gantry angle, collimator angle, jaws positions, couch position, delivered dose in MU, beam status, control points, carriage position and MLC leaf The file records the linear dimensions in cm, rotational scale in degree and dose in MU. The leaf positions stored in the trajectory log file are the position of leaves at isocentre. After each dynamic MLC (DMLC) field delivery the trajectory log file for that particular field is written to a file on the control system computer. There is no trajectory log file recorded when the beam is paused either due to minor fault or user interruption by pressing beam off button. Figure 1: Fluence map derived from the expected leaves Figure 2: Fluence map derived from the actual leaves 2016 Rajesh Kumar and SD Sharma. Volume 1 Issue 1 CROOA-1-001 Page 2 of 5

Figure 3 presents the percentage error between fluence derived from expected leaves positions and actual leaves Figure 4: Histogram showing difference in fluence derived from the actual and expected leaves Figure 3: Percentage error in fluence map derived from the actual and expected leaves Figure 4 shows error between fluence derived from expected leaves position and actual leaves To validate the developed software tool, intentional errors in leaves positions were introduced and fluence was calculated. Figure 5 shows the percentage error in fluence derived from the actual and expected leaves positions with and without intentional errors. Figure 5: Difference in fluence map derived from the actual and expected leaves positions (a) without intentional error (b) with intentional error. (a) (b).the circled zone indicates the region where error was introduced and it is being clearly visible in the fluence map. This validation gives confidence that developed tools are working for the intended purpose. Minimum, maximum, mean, median and mode of percentage errors between expected and actual fluence for twenty six IMRT field treated by Truebeam accelerator are shown in Table 1. It can be observed from the data in this table that the percentage error in fluence calculated from expected and actual leaves positions are almost negligible. In all the cases studied, median and mode of percentage errors are zero while mean ranges from -0.01 to 0.003. Minimum and maximum values of percentage error are in range of -1.1 to 1.04. The error between expected and actual leaves positions are found to be as expected. These results indicate that the leaves positions are well monitored in the Truebeam LINAC using reliable control system. It is also important to add here that these IMRT fields were found acceptable for patient treatment through conventional patient specific QA methods (such as gamma analysis using 2D detector system). 2016 Rajesh Kumar and SD Sharma. Volume 1 Issue 1 CROOA-1-001 Page 3 of 5

MU However, the log files based analysis can be performed with every treatment field without giving extra dose to the patient as well as without taking extra machine time. 120 100 80 60 40 20 0 0 10 20 30 Expected MU Actual MU Figure 6: Variation of expected and actual Monitor Unit (MU) with time. Figure 6 shows the plot of the expected and actual MU with respect to the time. It is observed from this plot that the expected and actual MU with respect to the time is matching very well. There are no noticeable variations in the expected and actual MU. Similar results were observed for other field also. In this way, each treatment field can be verified without extra machine time and error due to MLC leaves positions can be eliminated. Time(sec) Table 1: Relative percentage error between expected and calculated fluence for Truebeam medical electron linear accelerator. Treatment Field Relative percentage error between expected and delivered fluence Minimum Maximum Mean Median Mode 1-0.8 0.15 0.0030 0 0 2-1.3 0.71-0.0100 0 0 3-0.65 1.00 0.0010 0 0 4-0.61 0.84-0.0020 0 0 5-0.22 1.04-0.0004 0 0 6-0.57 0.81-0.0004 0 0 7-0.16 0.16-0.0030 0 0 8-0.14 0.14-0.0030 0 0 9-1.1 0.55-0.0044 0 0 10-0.72 0.46-0.0013 0 0 11-0.68 0.53-0.0023 0 0 12-0.73 0.91-0.0011 0 0 13-0.62 0.28-0.0017 0 0 14-0.79 0.97 0.0002 0 0 15-1.02 0.74-0.0084 0 0 16-0.15 0.26-0.0008 0 0 17-0.67 0.15-0.0040 0 0 18-0.97 0.13-0.0050 0 0 19-0.64 0.34-0.0031 0 0 20-0.87 0.87-0.0030 0 0 21-0.67 0.49-0.0030 0 0 22-1.18 0.67-0.0028 0 0 23-1.28 0.46-0.0070 0 0 24-0.47 3.18 0.0013 0 0 25-0.17 1.35 0.00052 0 0 26-0.58 0.8 0.0070 0 0 2016 Rajesh Kumar and SD Sharma. Volume 1 Issue 1 CROOA-1-001 Page 4 of 5

Conclusions Software tools were developed to analyse the MLC Log files of Truebeam LINAC as patient specific QA in IMRT. The based fluence map estimated through log files analysis shows that the dose delivered to the patient by the Truebeam LINAC is highly accurate. This tool can be used as patient specific IMRT QA for other medical LINAC as well. Acknowledgement Authors express their sincere thanks and gratitude to Dr. KS Pradeepkumar, Associate Director, Health Safety and Environment Group and Shri DAR Babu, Head, Radiological Physics and Advisory Division for their constant encouragement and support in this work. Authors also express their thanks and gratitude to Dr. Howard Amols, Memorial Sloan Kettering Cancer Center, New York, USA for providing required facilities in this work. References 1. Galvin JM, Ezzell G, Eisbrauch A, Yu C, Butler B, Xiao Y, et al. Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. Int J RadiatOncolBiolPhys 2004; 58:1616 34. 2. Ezzell GA. Quality Assurance: When and what is enough for IMRT? In: IntensityModulated Radiation Therapy: The State of the Art. American Association of Physicists in Medicine Medical Physics Monograph No. 29. Madison, WI, USA: Medical Physics Publishing; 2003. p. 613 16. 3. Ezzell GA, Galvin JM, Low D, Palta JR, Rosen I, Sharpe MB, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. Med Phys 2003;30:2089 115. 4. Escude L, Linero D, Molla M, Maralbell R. Quality assurance for radiotherapy in prostate cancer: Point dose measurements in intensity modulated fields with large dose gradients. Int J RadiatOncolBiolPhys 2006; 66: S136 40. 5. Alber M, Broggi S, Wagter CD, Eichwurzel I, Engström P, Fiorino C, et al. Guidelines for the Verification of IMRT. ESTRO BOOKLET NO. 9. ESTRO Mounierlaan 83/12 1200 Brussels (Belgium) 2008. 6. Li JS, Lin T, Chen L, Price RA, Ma CM, Uncertainties in IMRT dosimetry, Med Phys 2010; 37: 2491-2500. 7. Kumar R, Sharma SD, Amols HI, Mayya YS, Kushwaha HS. A survey on the quality assurance procedures used in intensity modulated radiation therapy (IMRT) at Indian Hospitals. J Cancer SciTher 2010; 2.6:166 170. 8. Ibbott GS, Followill DS, Molineu HA,. Lowenstein JR, Alvarez PE, Roll JE, Challenges in credentialing institutions and participants in advanced technology multi-institutional clinical trials, Int J RadiatOncolBiolPhys 2008; 71: S71-S75. 9. Bogdanich W, Radiation Offers New Cures, and Ways to Do Harm, The New York Times, The New York Times Company, New York, 2010. 10. Bogdanich W, As Technology Surges, Radiation Safeguards Lag, The New York Times, The New York Times Company, New York, 2010. 11. Dong L, Antolak J, Salehpour M, et al. Patient-specific point dose measurement for IMRT monitor unit verification. Int J RadiatOncolBiolPhys 2003;56:867-877. 12. Fenoglietto P, Laliberte B, Ailleres N, et al. Eight years of IMRT quality assurance with ionization chambers and film dosimetry experience of the Montpellier Comprehensive Cancer Center. RadiatOncol 2011;6:1-11. 13. Pulliam K, Followill DS, Court L, et al. A review of more than 13000 patient-specific IMRT QA results. J ApplClin Med Phys. 2014;15(5): 196-206. 14. Luo W, Li J, Price RA, Chen L, Yang J, Fan J, Chen Z, McNeeley S, Xu X, Ma CM, Monte Carlo based IMRT dose verification using MLC log files and R/V outputs, Med Phys 2006; 33:2557-2564. 15. Agnew CE, King RB, Hounsell AR, McGarry CK: Implementation of phantom-less IMRT delivery verification using Varian DynaLog files and R/V output.phys Med Biol 2012, 57(21):6761-6777. 16. Sun B, Rangaraj D, Boddu S, Goddu M, Yang D, Palaniswamy G, Yaddanapudi S, Wooten O, Mutic S, Evaluation of the efficiency and effectiveness of independent dose calculation followed by machine log file analysis against conventional measurement based IMRT QA,J ApplClin Med Phys2012;13(5):3837. 17. Dineshkumar M, Thirmavalavan N, Venugopal KD, Babaiah M. QA of intensity modulation beams using dynamic MLC log files. J Med Phys. 2006; 31(1): 36-41. 18. True beam Trajectory Log File Specification, Varian Medical Systems; 2011. Please Submit your Manuscript to Cresco Online Publishing http://crescopublications.org/submitmanuscript.php 2016 Rajesh Kumar and SD Sharma. Volume 1 Issue 1 CROOA-1-001 Page 5 of 5