How To Install A Fire Sprinkler



Similar documents
WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

Roland Garcia Pearland Fire Department

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Use Of Residential Fire Sprinklers In New Housing Projects

Your Instructor. Two Biggest Obstacles to Residential Sprinklers. Two Biggest Obstacles to Residential Sprinklers

MARKETING HOMES PROTECTED BY FIRE SPRINKLER SYSTEMS

C I T Y O F S E L M A F I R E D E P A R T M E N T

Home Fire Sprinkler Facts vs. Myths

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

FIRE SPRINKLER TALKING POINTS

EFSN Training i Module Minutes

PROTECT WHAT YOU VALUE MOST

Fire Sprinkler Fact Sheet

Maintaining Fire Protection Systems

Fighting Fire in Sprinklered Buildings. Student Guide

HOME FIRE PROTECTION SYSTEMS SPRINKLER SYSTEMS IN INDUSTRY

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Viking Residential Sprinkler Installation Guide

Automatic Fire Sprinkler Submittal Requirements

FIRE-FIGHTING DESIGN BRIEF REPORT

Residential Sprinkler Systems

What builders need to know about home fire sprinklers

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Section 9 Major Urban Fire

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Fraternity and Sorority House Fire Safety

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Sprinkler Systems in Hospitals. Lisbon 6 November 2008

What to Expect From the Examination. How to Study the Plumbing Codes

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Fire Pump Plan Review March 2010

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

LESSON PLAN FIRE PREVENTION AND SAFETY

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

CITY OF MEDFORD INTEROFFICE MEMO

DESIGN GUIDE FOR INSTALLING PARTIAL SPRINKLER PROTECTION IN UNFINISHED BASEMENT AREAS

Making Your Home Ready For Solar Water Heating

Extended Coverage Sprinklers

Preventing Overheated Boiler Incidents

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM


TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs

Solar Water Heating SPECIFICATION, CHECKLIST AND GUIDE

SIZING OF WATER PIPING SYSTEM

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Licensing & Certification

To many people, a home s plumbing system is perceived as being extremely

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Winnipeg Fire Department Fire Prevention Branch

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

FIRE SPRINKLER DEMONSTRATION TRAILER

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Amendments to the 2012 International Plumbing Code

WHITE PAPER: UPGRADING THE HOME: LUXURY vs. SAFETY

Fire detection, alarm, and suppression systems are installed to:

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Town House Center Highway North Huntingdon, PA 15642

Smoke Alarm Performance in Residential Structure Fires

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

How to Protect Your Property Against Plumbing Disasters

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

COMMON MYTHS ABOUT FIRE SPRINKLER PROTECTION

Quik Lining Systems Heater Owners Guide

When Should Examination Preparation Begin?

FIRE SAFETY ONLINE TRAINING

HomeSpec REPORT SUMMARY

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Resources. Presentation By: Wayne Waggoner, NFSA

Name Of Occupancy Date. Yes No Describe

One of the fundamental design elements that every

Transcription:

Fire Sprinklers: Coming to a Home Near You With a smoking record for saving lives and protecting houses, it s no surprise sprinklers were adopted into the International Residential Code BY CHRIS ERMIDES While photographing an article with an electrician a couple of years ago, I got a tour of his new home. It was well built and, of course, had a vast array of high-tech gadgets. But what caught my attention most was the set of valves and gauges that shot from the home s main water-supply line. Is that for your radiant-floor heat? I asked, pointing to the pressure gauge, the backflow switch, and a couple of shutoffs. He grinned and said, Sprinkler system. He s a man of few words, but he s also a full-time firefighter. I knew that he wasn t talking about sprinklers that water the lawn. He then told me that smoke alarms reduce the risk of dying in a fire by only 50%. Smoke alarms and fire sprinklers combined, however, lower the risk by 82%. Given those numbers, adding 1.5% to the construction cost of his home felt like a worthy investment. Apparently, a lot of other people think so, too, because the International Code Council, the governing body responsible for the International Residential Code (IRC), approved a proposal to require fire sprinklers in all new homes. The requirement appears in the 2009 IRC, but it won t take effect until Jan. 1, 2011. This new code won t be adopted automatically by the 48 states that follow the IRC, however. Each state and local building department responsible for code changes will have the final say. Many areas already have residential sprinkler codes on the books, though, and some have had them in place for decades. Sprinklers save lives and houses According to the U.S. Fire Administration, a house fire starts about every 80 seconds in this country. In the 414,000 fires that occurred in 2007, nearly 3000 people lost their lives, and 14,000 were injured. Besides the casualties, $7.5 billion went up in flames. In Scottsdale, Ariz., home fire sprinklers have been mandatory since 1986. More than 50% of the houses there (about 41,000) are now protected by sprinklers. According to a 20-year study known as the Scottsdale Report, the Rural/Metro Fire Department found that of the 598 house fires that occurred, there were no fatalities in the 49 homes equipped with fire sprinklers. In the houses that weren t protected, 13 people died. The average fire loss in homes with sprinklers was $2166, compared with $45,019 in homes without them. Sprinkler activates (Without sprinklers, flashover can occur) Smoke alarm activates Flashover (No one survives flashover) Fire equipment set up Fire extinguished DETECTION OF FIRE REPORT OF FIRE FIRE- FIGHTERS DISPATCHED RESPONSE TO FIRE SETUP FIGHTING THE FIRE TIME IN MINUTES 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 According to the U.S. Fire Administration, a house fire starts about every 80 seconds in this country. In the 414,000 fires that occurred in 2007, nearly 3000 people lost their lives, and 14,000 were injured. Besides the deaths and injuries, $7.5 billion went up in flames. 42 FINE HOMEBUILDING Photo top left, facing page: Courtesy of Uponor

BULB TYPE In a bulb-type head, an exposed trigger mechanism holds a plug in place to keep water from discharging. The glass tube is filled with a red glycerin-based liquid and an air bubble. Heat expands the air bubble and the liquid, shattering the glass and releasing the plug. Plug Trigger mechanism: vacuum-sealed glass tube Air bubble Deflector plate Less expensive but visible. Exposed recessed pendant and horizontal sprinkler heads are the most recognizable and least expensive. They cost about $40 each, including the escutcheon plate. A less obtrusive dome type, which conceals the bulb until the trigger temperature is reached, costs about $50 each. SPRINKLER HEADS ARE HEAT-ACTIVATED Wall- or ceiling-mounted sprinkler heads are connected to a network of piping. Each head functions independently, so only the head(s) closest to the fire will activate. The heads all have a plug held in place by a bulb-type or solder-type heat-sensitive trigger mechanism. Once the mechanism reaches its activation temperature, it releases the plug and the water. Water then sprays over the deflector plate, which disperses it evenly around the room. Standard sprinkler heads are set to activate at 155 F. Because they re heat sensitive, they should never be painted or covered. Most manufacturers can color- match and offer a variety of styles. The examples shown here illustrate the most common styles. Wall mount Dome type SOLDER TYPE In a solder-type head, a concealed trigger mechanism made up of spring arms and a solder plate engages the plug. Heat melts the solder, releasing the spring arms and the plug. In the flush-concealed style shown here, solder also secures a plate that sits flush with the ceiling. Heat releases the flush plate and the retractable deflector plate, exposing the sprinkler head. Once the head is exposed, it is ready to be activated by a higher temperature. Plug Trigger mechanism: spring arms and plate Retractable deflector plate Flush plate More costly but hidden. Flush concealed sprinkler heads (left) cost about twice as much as bulb-type heads (about $65 each). A soldertype flush-pendant (above) costs about $15 more. www.finehomebuilding.com OCTOBER/NOVEMBER 2009 43

States including Illinois, Maryland, and Oregon have also had residential fire-sprinkler codes on the books for years. Whether municipalities are going to adopt the new rule is still unclear, and very much up for debate. The National Association of Home Builders (NAHB) is working to convince states that they should block municipalities from adopting the new code; so far, 10 states have legislation in the works to do just that. The NAHB fears the added cost of sprinklers will deter people from building a home. Local adoptions have been growing around the country, including areas served by volunteer fire departments, says Darren Palmieri, product manager for Tyco Fire Suppression and Building Products (www.tyco-rapidresponse.com). Sprinkler systems can lessen the strain on municipal fireprotection services, which can help in areas with dwindling volunteer rates. Although sprinkler systems aren t meant to replace firefighters, their purpose is to save lives. Most fire-related deaths in a house happen within five to 10 minutes of ignition. This critical point is called flashover, when all combustible materials within a room simultaneously ignite. No one survives flashover. Sprinklers control the fire enough to delay flashover. They buy time for the home s occupants and for the fire department. Pinpoint protection only when you need it A sprinkler system is composed of a series of heads tied into a network of piping fed by the home s water system. The standard coverage per head is a 12-ft. by 12-ft. area, though most sprinkler heads are listed to cover areas up to 20 ft. by 20 ft. The head closest to the fire will activate once it detects a temperature of 155 F. According to a study referenced on Homefiresprinkler.org, in about 90% of homes, only one sprinkler is necessary to control a fire. Fire-sprinkler systems are extremely reliable, and the technology is fully developed, according to Julius Ballanco, president of the American Society of Plumbing Engineers. But even though the systems have a proven track record, some misconceptions remain. One of the most common is that a sprinkler head can activate accidentally. However, statistics show that only one in 16 million heads discharges falsely. Because sprinklers are heat activated, some consumers remain wary of high air temperatures that might naturally exist at the ceiling. In some areas of the home, like laundry rooms and near stoves, temperatures can run high up at the ceiling, Palmieri says. In these cases, sprinklers rated to activate at a higher temperature should be used. The other common misconception is that water damage is significant. Again, that s a poorly founded notion. The Home Fire Safety Institute says that a fire hose disperses an average of 2935 gal. to control a fire, whereas a sprinkler system dumps only 341 gal. Option 1 FIRE PROTECTION AND PLUMBING IN ONE TEE TO A S I N G L E FIXTURE An inline tee reduces the 1-in. PEX to ½ in. to feed a single fixture. There are two options The National Fire Protection Association s NFPA 13D is the standard for the installation of sprinkler systems in one- and two-family homes. It requires sprinklers in living areas only, not in smaller bathrooms or closets, nor in pantries, garages, attics, or other concealed nonliving spaces. The system s piping must be charged with water at all times and can be configured in one of two ways: as a stand-alone or as a multipurpose system. In a stand-alone system, the piping is separate from the rest of the house s plumbing. Water in these systems is stagnant, so depending on the type of piping used and the local requirements, a backflow valve may be required. Some local codes also require a flow alarm, a device that sounds by sensing the flow of water when a sprinkler head discharges. The alternative a multipurpose system is tied into the home s plumbing system 44 FINE HOMEBUILDING Drawings: Chris Mills

LIMITED TURNING RADIUS One-in. PEX is tough to bend and could require elbows for tight turns. SPRINKLERS FIRST A loop of 1-in. PEX is designed with head location in mind. Cold-water lines branch off to feed fixtures. MULTIPLE F I X T U R E S, MULTIPLE TEES Feed from water main A multipurpose system is integrated with the house s plumbing, unlike a stand-alone system, which is separate (p. 46). One pipe loop with sprinklers is run off the main water line, and cold-water lines branch off to feed the kitchen and the bathroom. Combined plumbing and sprinkler systems can be piped using PEX (example shown here), CPVC, or copper; the pipe must be NSFand UL-approved. Manufacturers typically engineer their systems for each project and train the installers, who are often plumbers. Any future remodeling work that affects plumbing could require additional engineering. An inline tee reduces 1-in. PEX to 3 4 in. A multiport tee reduces it again to 1 2 in. to feed individual fixtures. COVERAGE VARIES Each sprinkler head operates independently. The standard coverage per head is a 12-ft. by 12-ft. area, though sprinkler heads can cover areas up to 20 ft. by 20 ft. Fire www.finehomebuilding.com OCTOBER/NOVEMBER 2009 45

Option 2 A SYSTEM DEDICATED TO DOUSING FIRES A stand-alone system is composed of a separate set of CPVC or copper pipes and fittings dedicated just to the sprinklers; water does not mix with the home s plumbing. The system is fed from a riser that tees off the Flow switch home s main water line. Because the water in the stand-alone system is stagnant, a backflow valve might be required to ensure that Backflow valve it does not contaminate the home s water lines. A gauge monitors the pressure, while a flow switch alerts the home s occupants when water is moving through the sprinkler system. In most states, a stand-alone system can be installed only by a licensed sprinkler installer. Manufacturers suggest testing the system annually to make sure all valves and switches are working properly. Because this system is separate from the home s plumbing, future remodeling work won t affect the sprinkler setup. Fire-rated CPVC pipe and fittings carry water to each sprinkler head. They assemble like typical PVC and CPVC pipe with solvent cement. and shares cold-water distribution lines. This type of system does not require backflow prevention. Stand-alone systems typically must be installed by a certified sprinkler fitter. Dominick G. Kasmauskas, regional manager for the National Fire Sprinkler Association in New York, says some states require that multipurpose systems be installed by a licensed sprinkler contractor. Houses that aren t connected to a public water supply can be protected as well. The downside, of course, is the higher cost. Sprinkler systems fed by a well require a holding tank and/or a pump strong enough to keep the system running should a sprinkler head activate. The NFPA 13D standard requires that there be enough water available to discharge 20 to 26 gal. per minute (gpm) for 10 minutes. Check, please The installation cost for sprinkler systems is what scares people most. According to the Fire Research Foundation, the national average is about 1.61% of overall construction cost, about $1.52 per sq. ft., but as high as $3.50 per sq. ft. or as low as 85 per sq. ft. As residential sprinkler systems become more common, it is likely that prices will become more competitive. There is some disagreement about which system is less expensive. Stephen Ziamandanis, a representative for Uponor (www.uponorusa.com) and a certification instructor, contends that multipurpose systems are far less expensive. You re using the same piping for your cold-water plumbing lines, which saves on material cost, he says, and you re saving labor costs because one contractor a plumber is installing one system. Stand-alone systems can t be installed by a plumber, unless he or she is also a certified sprinkler fitter, so there s another contractor to contend with. New sizing and installation guidelines added to the NFPA 13D and the IRC now allow the installing contractor to design either a stand-alone or a multipurpose piping system. Tyco has been conducting its own studies to determine if there s a cost difference between the systems. According to Palmieri, current findings suggest the two are about even. The material cost is less expensive than multipurpose, which balances out with the extra labor costs, he says. Julius Ballanco agrees: It seems to be about a wash. The most volatile cost these days is the tap cost, levied on any house connected to a municipal water system. A standard tap fee is about $50, depending on the area. Adding a sprinkler system will likely require a larger line ( 3 4 in. to 1 in.), which can run as high as $2000. Some areas are trying to charge a standby fee as well. Several states are getting involved to regulate tap fees and block standby fees. When amortized over the course of a 30-year mortgage, the cost of a fire sprinkler system isn t a financial burden for most people. Insurance companies often offer a discounted rate on homeowner s policies that can range from 5% to 15% if the house has sprinkler protection. The savings might not be significant, but a sprinkler system isn t the type of expense that can be calculated for a monetary return on investment. The investment is in a priceless commodity: life. Chris Ermides is an associate editor. Photos by Rodney Diaz, except where noted. Do you agree with this code change? Cast your vote in our online poll and join the discussion. FineHomebuilding.com/extras 46 FINE HOMEBUILDING Photos this page: Courtesy of Tyco Fire Suppression and Building Products