Meter Proxy Quick Start Guide



Similar documents
Configuring an APOGEE System on an IT Infrastructure White Paper

Backing Up and Restoring Data

EXTENDED FILE SYSTEM FOR FMD AND NANO-10 PLC

Backup and Recovery Procedures

EXTENDED FILE SYSTEM FOR F-SERIES PLC

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Downtime Reports. Administrator's Guide

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

LifeSize Control Installation Guide

IP Phone Configuration and Troubleshooting Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator s Manual for AddressBook Viewer

Legal Notes. Regarding Trademarks KYOCERA Document Solutions Inc.

File Transfers. Contents

Demo of Data transferring (.CSV Files) from EGX300 to Our local PC/Laptop using- FTP

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

SFTP Server User Login Instructions. Open Internet explorer and enter the following url:

DPS Telecom Your Partners in Network Alarm Management

Avaya Network Configuration Manager User Guide

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

How to Upgrade the Firmware of a Brother Printer/Print Server

Accounting Manager. User Guide A31003-P1030-U

Canon WFT-E1 (A) Wireless File Transmitter. Network Support Guide

TECHNICAL NOTE TNOI27

smartoci User Guide Secure FTP for Catalog Loads

inforouter V8.0 Server Migration Guide.

LifeSize Networker Installation Guide

Setting up the local FTP server

User Guidance. CimTrak Integrity & Compliance Suite

Getting Started with IntelleView POS Administrator Software

Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement

Deployment Guide for Maximum Security Environments Polycom HDX Systems, Version 3.0.5

Step-by-Step Guide for Creating and Testing Connection Manager Profiles in a Test Lab

Allworx OfficeSafe Operations Guide Release 6.0

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. August 2014 Phone: Publication: , Rev. C

Upgrading Software Using the Online Installer

technical brief browsing to an installation of HP Web Jetadmin. Internal Access HTTP Port Access List User Profiles HTTP Port

VRC 7900/8900 Avalanche Enabler User s Manual

Diamond II v2.3 Service Pack 4 Installation Manual

User s Guide. Security Operations Ver. 1.02

Secure TCP/IP connection Description for UMG 604, UMG 605, UMG 508, UMG 509, UMG 511 and UMG 512

Broadband Router ESG-103. User s Guide

Access Instructions for United Stationers ECDB (ecommerce Database) 2.0

Importing data from Linux LDAP server to HA3969U

Quick Start Guide. Cerberus FTP is distributed in Canada through C&C Software. Visit us today at

CTERA Agent for Linux

NetBak Replicator 4.0 User Manual Version 1.0

Apps for Android. Apps for iphone & ipad INS584-3

Installation Guide. Wyse S Class Conversion to ThinOS. Wyse Simple Imager TM Release Issue: PN: L Rev. C

Connecting to the Firewall Services Module and Managing the Configuration

Chapter 6 Using Network Monitoring Tools

MICROS e7 Credit Card Security Best Practices

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

Version 1.0 Revision MODBUS/TCP Ethernet Communication Interface API for the Intelligent Instrumentation WinCE Platform SETUP MANUAL

Chapter 4 Management. Viewing the Activity Log

Installing and Configuring vcenter Support Assistant

CentreWare Internet Services Setup and User Guide. Version 2.0

HP A-IMC Firewall Manager

NS Series Programmable Terminal FTP Function

User s Guide [Security Operations]


Configuration Backup Restore

Installing, Uninstalling, and Upgrading Service Monitor

How To Backup A Database In Navision

Note: these functions are available if service provider supports them.

CipherLab 5100 Time Attendance Utility Manual

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

Network Scanner Tool R3.1. User s Guide Version

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual

HP IMC Firewall Manager

Cloud Portal for imagerunner ADVANCE

CS WinOMS Practice Management Software Server Migration Help Guide

Diamante WiFi Wireless Communication User Guide. Linksys E1200

Honeywell Internet Connection Module

Avigilon Control Center System Integration Guide

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Implementing Microsoft SQL Server 2008 Exercise Guide. Database by Design

Backup & Restore Guide

Avalanche Remote Control User Guide. Version 4.1.3

WildFire Cloud File Analysis

User Guide. DocAve Lotus Notes Migrator for Microsoft Exchange 1.1. Using the DocAve Notes Migrator for Exchange to Perform a Basic Migration

Technical Brief for Windows Home Server Remote Access

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

Lab Answer Key for Module 1: Installing and Configuring Windows Server Table of Contents Lab 1: Configuring Windows Server

fåíéêåéí=péêîéê=^çãáåáëíê~íçêûë=dìáçé

UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0

RMS FTP PUBLIC. FTP Recommendations for Meter Data Retrieval. Issue 4.0 IMP_GDE_0085. Provides the three approaches to FTP as recommended by IESO.

Multi-Master DF1 Protocol User Guide

GlobalSCAPE DMZ Gateway, v1. User Guide

Contents. Preparation/SetUp...2

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall

Savvius Insight Initial Configuration

Chapter 6 Using Network Monitoring Tools

CA /BrightStor ARCserve9 Backup Software

DiskPulse DISK CHANGE MONITOR

Binary Upgrade Procedure

Chapter 4 Managing Your Network

Transcription:

Meter Proxy Quick Start Guide

Copyright Notice Copyright Notice Notice Document information is subject to change without notice by Siemens Industry, Inc. Companies, names, and various data used in examples are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Siemens Industry, Inc. All software described in this document is furnished under a license agreement and may be used or copied only in accordance with license terms. For further information, contact your nearest Siemens Industry, Inc. representative. Copyright 2014 by Siemens Industry, Inc. To the Reader Your feedback is important to us. If you have comments about this manual, please submit them to: SBT_technical.editor.us.sbt@siemens.com Product or company names mentioned herein are the trademarks of their respective owners. Printed in USA 2

Table of Contents Chapter 1 - Introduction... 4 What is the Meter Proxy?... 4 How the Meter Proxy Works... 4 Chapter 2 - Implementing Meter Proxy... 7 Step 1: Gathering Information for FTP Configuration... 7 Step 2: Planning the Structure of Trend Sample Report Analysis... 8 Step 3: Adding the License for Meter Proxy... 9 Step 4: Adding the Database... 9 Step 5: Configuring the Meter Proxy... 10 Configuring the FTP Server... 10 Displaying Properties of the FTP Server... 11 Modifying the FTP Server Configurations... 11 Step 6: Automating the Trigger Schedule... 12 Step 7: Verifying Data Transmission... 13 Verifying (S)FTP Connection and Transfer... 13 Verifying the Meter Proxy Trigger Point... 13 Adjusting Meter Proxy Trigger Time... 13 Backup, Restore, and Autorestore... 14 3

Chapter 1 - Introduction What is the Meter Proxy? Chapter 1 - Introduction This guide provides an overview of the Siemens Compact Meter Proxy, and a guide to how to enable and implement File Transfer Protocol (FTP) support in a Siemens Compact field panel that contains the Meter Proxy. NOTE: Before beginning, configure the panel using the PXC Compact Series Start-up Procedures (145-157). What is the Meter Proxy? The Meter Proxy allows a Compact 16 or 24 field panel to act as an FTP client and send a Trend Sample Report containing trend data directly to an FTP server. All trend data points contained in the Compact field panel are uploaded to an FTP server at a scheduled time interval. You can schedule the Trend Sample Report upload by configuring a trigger point that is commanded by the Scheduler or PPCL code. CAUTION The Meter Proxy will upload ALL trend points to the Trend Sample Report that are defined in the Siemens Compact field panel to the FTP server. The trend point definitions must have a sample interval equal to the sample interval of the Trend Sample Report. How the Meter Proxy Works The Meter Proxy is a licensable feature that can be added to Compact 16 and Compact 24 Series field panels, which allows the field panels to act as FTP clients to either standard or secure FTP sites. Meter Proxy is not shipped out of the factory. A firmware load of the BPXCCMP (acquired from Standard Apps) is required. The Meter Proxy feature is available for BACnet field panels with Firmware Revision 3.3 and later. This feature creates a file containing trended values for all points with trend definitions matching the Meter Proxy configuration. This file is then sent to a dedicated server using the industry standard FTP protocol. NOTE: You must specify Secure FTP or non-secure FTP mode when configuring the FTP settings from the Human-Machine Interface (HMI). 4

Chapter 1 - Introduction How the Meter Proxy Works Non-secure FTP typically uses port 20 and port 21 for file transmission. Secure FTP (SFTP) uses port 22 for file transmission in an encrypted format. CAUTION The FTP settings in the Meter Proxy are not standard FTP protocol settings. They have been modified (timing, etc.) to optimize file transfer to the Siemens Energy and Environmental Solutions Data Center. The Meter Proxy generates the Trend Sample Report when the FTP trigger point is turned ON. The Meter Proxy then uploads the report to the FTP server as a.csv file. If an error occurs, the FTP server's availability is checked every minute until an FTP connection is available. The report is then transferred to the FTP server. Once the schedule is met and changes the value of trigger point to "ON", a second schedule entry is required to change the trigger point value to "OFF". If the first schedule changes the trigger point value to "ON" and the trigger point remains "ON", the field panel will send trend data every minute until the trigger point is changed to "OFF". Set the trigger point to switch from ON to OFF in 5 to 60 seconds (30 seconds recommended). You will have to adjust the time onsite due to timing issues caused by the local network that the files will be transferred through. When the report is transmitted successfully, the file at the field panel is deleted. If the server is not available, the file is not created until the FTP server is available. To verify access to FTP server site, it is recommended that you use the freeware FTP Client program, FileZilla, (or similar FTP client software) which you can download from the Internet (http://filezilla-project.org). The following illustration shows the process that the firmware uses to upload the Trend Sample Report (.CSV file) to the FTP site. 5

Chapter 1 - Introduction How the Meter Proxy Works 6

Step 1: Gathering Information for FTP Configuration Chapter 2 - Implementing Meter Proxy This chapter provides a guide for implementing the Meter Proxy firmware in Compact Series field panels. It includes the following topics: Step 1: Gathering Information for FTP Configuration Step 2: Planning the Structure of Trend Sample Report Analysis Step 3: Adding the License for the Meter Proxy Step 4: Adding the Database Step 5: Configuring the Meter Proxy Step 6: Automating the Trigger Schedule Step 7: Verifying Data Transmission Step 1: Gathering Information for FTP Configuration To implement the FTP configuration, you must be prepared to specify the following: The server IP address (provided by the target system administrator). CAUTION A maximum of 15 characters is allowed. Entering a URL or computer name is not supported. A User Name and Password (provided by the target system administrator). CAUTION User Name and Password must be from 6 to 15 characters. DO NOT use the # symbol in the User Name or Password. The secure mode for Secure FTP (y/n), which is determined by the target directory. CAUTION The target directory on the SFTP or FTP site in which the trend data file will be located has been built into the firmware. SFTP setup will place trend data files in the root directory of the SFTP site. Non-secure FTP must be set up to use the [root]/anon_ftp/usc/toserver directory to receive trend data. 7

Step 2: Planning the Structure of Trend Sample Report Analysis Step 2: Planning the Structure of Trend Sample Report Analysis Plan what trend sample intervals will be used in the Trend Sample Report and Trend Point Definitions. Remember, the Trend Sample Report and Trend Point Definitions must have the same trend sample interval. Determine the file name prefix for the Trend Data File (such as Main_Hospital ). You must specify the.csv file name prefix (FTP File Prefix) through the HMI; this is done in Step 5: Configuring the Meter Proxy. When you fill in the prompts for Meter Proxy, one prompt is for "FTP File Prefix". The text you enter is part of the file name for the.csv file. For example: SIEMENS_03182009_111949_AM_20.CSV, where SIEMENS is the file prefix, and the rest is appended to it for date, time, and field panel ID. Typically the prefix name is the Client Name. Whenever the trigger point is turned ON, the field panel creates a.csv file which is named using the following format: <FTP File Prefix>_<mmddyyyy>_<hhmmss>_<AM/PM>_<panel ID number>.csv For example: SIEMENS_3182009_111949_AM_20.CSV The FTP file prefix (client name) is stored in flash memory so that it can be retrieved after a coldstart. Determine the trend sample interval required for the Trend Sample Report (15 minutes recommended). Determine the trend definition sample interval for points being trended. A maximum of 25 points may be included in the Trend Sample Report. 700 samples (seven days worth of data) per point are recommended so that sufficient data is stored in case of an extended communication loss. The trend sample interval defined for a point must match that defined in Ftpsettings or trend data for that point will not be included in the Trend Sample Report. Create a trigger point to initiate Trend Sample Report (can be a physical or virtual point). You must specify a trigger point that is associated with the FTP configuration. The trigger point must be a physical or virtual LDO or LDI point residing in the Compact with Meter Proxy field panel. It is recommended that the trigger point be defined as Normally Open (not Inverted). A Normally Closed (Inverted) trigger point may result in unexpected behavior. The schedule or PPCL will use this trigger point to determine when trend data should be sent to the FTP server. As the value of this trigger point changes according to the schedule or PPCL, a.csv file containing the trend data for all the trended points will be created and uploaded on to the FTP server. The Trend Sample Report (.CSV file) contains only one trend interval for all the trended points. The trend interval used is defined by the user during the FTP settings configuration. 8

Step 3: Adding the License for Meter Proxy Step 3: Adding the License for Meter Proxy Use the following steps to add the license for the Meter Proxy (LSM-EMP): HMI S, H, L, A (System, Hardware, Licensemanager, Add) Prompt/Field Option/Entry Description License Begin typing the license number (or copy and paste) Press ENTER Continue typing the license (or copy and paste) Repeat until the entire license number is entered Press ENTER Stop typing before the end of the line License prompt displays Blank line indicates the end of text entry. The following text is displayed for a successful license entry: License 1 accepted Licenses received 1, Licenses accepted 1, Licenses rejected 0 Log, Display, Add, delete, Removall, Quit? Panel coldstarts. The license entered is checked for its validity. If the license is not valid, the license is rejected. If the license is valid, it is accepted, and you can perform all the FTP Trend functionality. If the license is not installed, the FTP task is not created and no.csv file is created and uploaded to the FTP server. If you attempt to configure the FTP without a License, the following error displays: FTP Trend license not installed. Once entered and accepted, a valid FTP Trend license remains persistent even after coldstart. NOTE: If an FLN license is required, repeat Step 3, adding the license for the FLN(LSM- FLN). Step 4: Adding the Database One of the required FTP settings is a trigger point name. This trigger point name must exist in the database before it can be used in the FTP settings. Therefore, the database (or at least the trigger point name) must be added to the field panel before continuing. 9

Step 5: Configuring the Meter Proxy You can add the entire database to the field panel using information in the PXC Compact Series Start-up Procedures (145-157), or you can add only the Meter Proxy trigger point name. Refer to the APOGEE BACnet ALN Field Panel User's Manual (125-3020) for information on how to add a point. Step 5: Configuring the Meter Proxy Configure Meter Proxy using the HMI configuration commands. The following HMI commands allow you to: Specify the trigger point name Specify the FTP server IP address Specify the.csv file prefix Specify the user name and password Specify secure mode or unsecure mode Specify the trend time interval samples to be included in the report Configuring the FTP Server To configure the FTP server, use the following HMI commands: HMI S, H, E, F (System, Hardware, Ethernet, Ftpsettings) Prompt/Field Option/Entry Description Display, Modify, Quit? D, M, Q >Point, Application, Time, Message, Cancel, System, password, Bye? S >Diagnostics, Users, dst, Bacnet, Error_msgs, Hardware, Text, Quit? H >Fieldpanels, Ethernet, nodenametable, Disks, Reportprinter, Licensemanager, Quit? E >ipsettings, Bbmd, smmpmanger, Telnet, Webserver, mibpoints, Ftpsettings, Quit? F 10

Step 5: Configuring the Meter Proxy Displaying Properties of the FTP Server Use the following commands to display the trigger point name, FTP server IP address, FTP User Name, FTP File Prefix, Secure mode, and trend data recording schedule. Use these commands again after modifying the FTP server properties in order to verify that the modifications are accurate: HMI S, H, E, F, D (System, Hardware, Ethernet, Ftpsettings, Display) >Point, Application, Time, Message, Cancel, System, password, Bye? S >Diagnostics, Users, dst, Bacnet, Error_msgs, Hardware, Text, Quit? H >Fieldpanels, Ethernet, nodenametable, Disks, Reportprinter, Licensemanager, Quit? E >ipsettings, Bbmd, snmp, Telnet, Webserver, Ftpsettings, Quit? F >Display, Modify, Quit? D 06/30/2011 THU FTP CONFIGURATION REPORT 14:01 ------------------------------------------------------------------------------- Trigger Point Name : TRIGGER FTP Server IP : 172.168.1.1 User Name : siemens FTP File Prefix : SIEMENS Secure Mode : Y Record every : 15 Minutes End of report Modifying the FTP Server Configurations You must overwrite the existing IP address with a new IP address, user name, FTP file prefix, and trigger point name. Use the following commands to modify the existing FTP server configuration: HMI S, H, E, F, M (System, Hardware, Ethernet, Ftpsettings, Modify) Prompt/Field Option/Entry Description Trigger Point Name: FTP Server IP: User Name: Enter the trigger point name. Press CTRL+U to clear the IP address. Then enter the new address. Setting the IP address to 0.0.0.0 disables the feature (default setting). Enter the new user name: Default is siemens 11

Step 6: Automating the Trigger Schedule Existing Password: New Password: FTP File Prefix: You must get the User Name and Password from the target system administrator. Enter the existing password: Default is high$123 Enter the new password or the same password if not changing. Enter the new FTP client name. The file prefix specified will be appended to the filename created. Secure mode: Y, N Press Y to enable for a secure FTP Client. Press N to disable for a non-secure FTP Client. Trend in Hours, Minutes: M, H Specify whether the trend is required in minutes or hours. Minutes/Hrs between samples: Command Successful displays. Specify the trend interval. The trend will occur for the value given in minutes or hours between displayed lines. Once set, these parameters are stored in the FLASH memory of the Siemens controller. Step 6: Automating the Trigger Schedule To generate a Trend Data File for uploading to the FTP Server site, you must create the Schedule/PPCL to toggle the trigger point ON and then OFF again. When the scheduled time is reached and the value of the trigger point is turned ON, the field panel will check for the availability of the FTP server. The field panel will also check the availability of FTP server every one minute if the server is not available. The.CSV will only be generated once a FTP connection is established. When the FTP server is available, trend data will be collected, the RAMDisk will be checked for its space availability, the Trend Data File (.CSV file) will be created with the collected samples and on a successful transfer, the file will be deleted from the field panel to create space for the new.csv files. If the amount of RAMDisk memory available is not enough for uploading all the collected samples, a.csv file will be created with the available space and then the leftover samples will be uploaded in a new.csv file. If the.csv file is not properly uploaded, the field panel FTP client will try connecting to the FTP server again after one minute. The field panel FTP client will not stop trying until the file has been successfully uploaded to the defined FTP server. If the trigger point is left ON, reports will continue to be generated as quickly as possible, which is approximately every two minutes. 12

Step 7: Verifying Data Transmission NOTE: The trigger point command must be sent at BACnet priority 16 (BN16) in order to activate the (S)FTP transfer of the Trend Sample Report. Step 7: Verifying Data Transmission Verifying data transmission involves the following: Verifying (S)FTP Connection and Transfer Verifying the Meter Proxy Trigger Point Adjusting Meter Proxy Trigger Time Verifying (S)FTP Connection and Transfer Before attempting to send a data file to the SFTP server, verify that the customer site network firewall allows access to the SFTP site. Ethernet ports 20, 21, and 22 must be open. Connect your computer to the same Ethernet switch as the Compact with Meter Proxy and use separate FTP client software (such as FileZilla) to access the SFTP server location and upload a dummy file to the SFTP site. Transferring the Trend Data File from the Meter Proxy to the SFTP server is an automatic process. To verify that the Meter Proxy has uploaded the file to the SFTP server, use the same separate FTP client software as above (such as FileZilla) to access the SFTP server location and verify that the automatic process was successful. Verifying the Meter Proxy Trigger Point Before you attempt to upload a file to the SFTP server, verify that the schedule or PPCL that commands the trigger point works properly. It s recommended that you use an LED from one of the panel s LDOs. Use the LED to count how long the trigger is turned ON. Following is sample PPCL for proxy triggers. Run the trigger PPCL as a separate PPCL program. 08000 C TURN ON/OFF CSV TRIGGER POINT DAILY 08010 IF(TIME.LT. 05:00.OR. TIME.GE. 05:01) THEN GOTO 8050 08020 IF(SECND1.LT. 1.0) THEN ON("TRIGGER") 08030 IF(SECND1.GT. 30.0) THEN OFF("TRIGGER") 08040 GOTO 10000 08050 SECND1 = 0.0 08060 OFF("TRIGGER") 10000 GOTO 1000 Adjusting Meter Proxy Trigger Time The trigger point must remain ON long enough for the Trend Data File to be transferred, but not more than 60 seconds or the file will be sent twice. Therefore, the trigger point must be turned OFF by the schedule or PPCL within this time. 13

Back up, Restore, and Autorestore You must set the trigger point for a minimum of 5 seconds; the trigger time will depend on network conditions at the job site. This means that the trigger time could be anywhere from 5 to 60 seconds. You should start with an initial trigger time of 30 seconds. If the Trend Data File is not sent, increase the trigger time. Example of.csv output file (text format): Key,Name:Suffix,Trend Definitions Used Point_1:,SBT_BOH2_DEM2_KW,15 Minutes Point_2:,SBT_BOH2_DEM2_KWH,15 Minutes Point_3:,SBT_BOH2_DEM2_TUE,15 Minutes Point_4:,SBT_BOH2_DEM3_KW,15 Minutes Point_5:,SBT_BOH2_DEM3_KWH,15 Minutes Point_6:,SBT_BOH2_DEM5_KW,15 Minutes Point_7:,SBT_BOH2_DEM5_KWH,15 Minutes Point_8:,SBT_BOH2_DEM6_KW,15 Minutes Point_9:,SBT_BOH2_DEM6_KWH,15 Minutes Point_10:,SBT_BOH2_OAT,15 Minutes Point_11:,SBT_BOH2_TOTAL_KWH,15 Minutes Date Range:,06/29/2011 13:46:43-01/06/2000 04:00:00 Report Timings:,All Hours <>Date,Time,Point_1,Point_2,Point_3,Point_4,Point_5,Point_6,Poin t_7,point_8,point_9,point_10,point_11 06/29/2011,14:00:00,12,3486,0.0,7,2453,27,9218,18,10224,0.0,2538 1 06/29/2011,14:15:00,7,3488,0.0,13,2456,25,9225,8,10227,0.0,25395 06/29/2011,14:30:00,7,3490,0.0,7,2457,28,9232,18,10230,0.0,25409 06/29/2011,14:45:00,13,3493,0.0,7,2460,25,9238,11,10233,0.0,2542 3 06/29/2011,15:00:00,12,3495,0.0,7,2461,21,9244,11,10238,0.0,2543 8 06/29/2011,15:15:00,7,3497,0.0,12,2464,25,9249,20,10242,0.0,2545 3 06/29/2011,15:30:00,7,3499,0.0,8,2467,24,9255,6,10246,0.0,25467 06/29/2011,15:45:00,12,3502,0.0,7,2469,30,9261,10,10249,0.0,2548 1 06/29/2011,16:00:34,7,3504,0.0,8,2471,20,9268,12,10253,0.0,25495 Back up, Restore, and Autorestore The field panel must be configured to automatically restore the database from flash memory after a coldstart, and Insight should not be used: When autorestore is enabled, a coldstart does not result in the same downtime as with earlier revisions of firmware. Because there is no waiting on a full download from the backup system, the database is restored from flash so quickly that it seems as though the field panel never coldstarted. 14

Back up, Restore, and Autorestore Database restoration from flash is disabled by default and should be enabled. HMI S, H, F, C, L (System, Hardware, Fieldpanels, Config, db_file) Next Sub-menu Option Prompt/Field Option/Entry Description Save, Clear Restore_db Autorestore Enable Disable Field panel Enter field panel name Are you sure (Y/N) Y Save, Clear, or Restore the database. Field panel N Enter field panel name Do not Save, Clear, or Restore the database. Are you sure (Y/N) Y Enable Autorestore. Display Field panel Enter field panel name N Disable Autorestore. In order to support autorestore and database backup to flash, the following new HMI prompts (bolded below) have been added. >Point, Application, Time, Message, Cancel, System, password, Bye? s >Diagnostics, Users, dates, destinations, Error_msgs, Hardware, Text, Quit? h >Fieldpanels, Ethernet, nodenametable, Disks, Partners, Licensemanager, Vaem, Quit? f >Log, Display, Add, delete, Modify, Config, Ostracize, Quit? c >Hmi, alnsettings, db_file, Fln, modem, Names, Defaultlanguage, Quit? l >Save, Clear, Restore_db, Autorestore, Display, Quit? s >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Database Backed Up to Flash >Save, Clear, Restore_db, Autorestore, Display, Quit? c >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Flash Backup Erased >Save, Clear, Restore_db, Autorestore, Display, Quit? r >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Command successful >Save, Clear, Restore_db, Autorestore, Display, Quit? a 15

Back up, Restore, and Autorestore >Enable, Disable, Quit? e >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Autorestore enabled >Save, Clear, Restore_db, Autorestore, Display, Quit? a >Enable, Disable, Quit? d >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Autorestore disabled >Save, Clear, Restore_db, Autorestore, Display, Quit? d >Field panel : --- 01/01/2006 SUN DB File Report 00:16 ------------------------------------------------------------------------------- Field panel : 6 Flash backup : Present Database size : 2482 bytes Last saved : 00:16:43 01/01/2006 SUN Result of last backup : Success Autorestore : Disabled File manager status : Idle End of report >Save, Clear, Restore_db, Autorestore, Display, Quit? a >Enable, Disable, Quit? e >Field panel : --- >Are you sure (Y/N) : y Field panel 6: Autorestore enabled >Enable, Disable, Quit? Q 16

Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. APOGEE is a registered trademark of Siemens Industry, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. 2014 Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Document No. Printed in the USA June 3, 2014 Page 17 of 15