Mosquito Control Guidelines



Similar documents
PRIVATE TREATMENT CONTROL BMP OPERATION AND MAINTENANCE VERIFICATION FORM BIORETENTION FACILITIES, VEGETATED SWALES & HIGHER RATE BIOFILTERS

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

Table 4.9 Storm Drain Inlet Protetion Applicable for

Outlet stabilization structure

Detention Ponds. Detention Ponds. Detention Ponds. Detention Ponds. Detention Ponds. Detention Ponds. CIVL 1112 Detention Ponds - Part 1 1/12

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

Stormwater/Wetland Pond Construction Inspection Checklist

SUSTAINABLE URBAN DRAINAGE SYSTEMS

Storm Drain Inlet Protection

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Retention/Irrigation. Design Considerations. Soil for Infiltration Area Required Slope Environmental Side-effects

City of Shelbyville Site Inspection Checklist

Standards Oversight Council (SOC) Supporting Technical Standards for Urban and Rural Soil and Water Conservation

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

SE-10 STORM DRAIN INLET PROTECTION. Objectives

piles of debris that accumulate after a rain such as leaves, trash, twigs, etc., water stains on fences and buildings, or salts extruded on bricks,

CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN TEMPLATE

Property Care White Papers. Site Drainage: Monitor and Maintain

Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.

Operation & Maintenance Document Templates

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

Homeowner s Guide to Drainage

STORMWATER MANAGEMENT CHECKLIST

CLACKAMAS COUNTY ZONING AND DEVELOPMENT ORDINANCE

Storm Drain Inlet Protection - IP

Storm Water Technology Fact Sheet Wet Detention Ponds

First in Service First in Safety

Block and Gravel Inlet Protection (BIP)

Beseck Switching Station Inspection

Construction Site Inspection Checklist for OHC By making use of some simple Best Management Practices (BMPs) a construction site operator can

4.3 Cisterns and Rain Barrels

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

Stormwater Ponds. c ıty of a bı le ne st or m wat e r utı lıty dıv ısı on

SECTION 5. Sediment Control Measures

BMP #: Dry Wells / French Drains

Storm Drain Inlet Protection

GREEN ROOFS. Location. Design SMALL COMMERCIAL GUIDE CITY OF ATLANTA, GEORGIA DEPARTMENT OF WATERSHED MANAGEMENT

Local Road Assessment and Improvement Drainage Manual

Permeable Pavement Construction Guide

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

Scheduling Maintenance for Infiltration Basins and Trenches

COMBINED SEWER OVERFLOW OPERATIONAL AND MAINTENANCE PLAN SUMMARY

Permeable Pavement Operation & Maintanence Guide

Post Construction and Redevelopment Inspection Manual

Seattle Public Utilities. Natural Drainage Systems (NDS) Maintenance Manual

APPENDIX F. RESIDENTIAL WATER QUALITY PLAN: ALLOWABLE BMP OPTIONS

CITY UTILITIES DESIGN STANDARDS MANUAL

Planning, Health and Environment Division

3.4 DRAINAGE PLAN Characteristics of Existing Drainages Master Drainage System. Section 3: Development Plan BUTTERFIELD SPECIFIC PLAN

City of Green Bay Department of Public Works Engineering Department

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

How to Build a Rain Garden at Your Home

Post Construction Stormwater Management Inspection & Maintenance PROGRAM MANUAL

Guidelines for Control of Water Runoff on Small Lots. Revised 6/09

Waste Handling & Disposal

Storm Water Management Requirements for Construction Projects Less than One Acre

BEST MANAGEMENT PRACTICES (BMPs)... What are They? GOOD HOUSEKEEPING PRACTICES Your Business Should Employ

CHAPTER 11 STORM DRAINAGE

Type of Sewer Systems. Solomon Seyoum

City of Paso Robles Community Development Department Construction Site Storm Water Quality Requirements

DISTRICT OF COLUMBIA WATER AND SEWER AUTHORITY. a guide to PREVENTING SEWER BACKUPS AND FLOODING

CHAPTER 5. Storm Sewer

SECTION 7- STORM SEWER

Emergency Spillways (Sediment basins)

APPENDIX B DESIGN GUIDELINES FOR APPROVED TREATMENT METHODS

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

GUIDELINES FOR SOIL FILTER MEDIA IN BIORETENTION SYSTEMS (Version 2.01) March 2008

8.1.3 General Design Guidelines. The following guidelines shall be used when designing inlets along a street section:

Water & Sewer Utility Maintenance SC-76

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

Standard Operating Procedures Storm Drain System Maintenance

Tree Pits Operation & Maintenance Guide

A Developer s Guide: Watershed-Wise Development

Riprap-lined Swale (RS)

CLIFTY CREEK PLANT MADISON, INDIANA

Storm Drain Inlet Protection for Construction Sites (1060)

BMP 6.4.6: Dry Well / Seepage Pit

CHAPTER 3A Environmental Guidelines for STREAM CROSSING BY ALL-TERRAIN VEHICLES

CASFM Stormwater Quality Field Trip June 23rd, 2011

Interlocking Concrete Pavement Institute (ICPI) Model Stormwater Ordinance for Permeable Interlocking Concrete Pavements August 2010

Selection of Stormwater Treatment Facilities For Maximum Extent Practicable Treatment Effectiveness in Compliance with NPDES Provision C.

Waterway Technote Drains

9.0 PUBLIC HEALTH (MOSQUITO ABATEMENT)

CHAPTER 3 STORM DRAINAGE SYSTEMS

ENVIRONMENTAL CODE OF PRACTICE FOR CONCRETE BATCH PLANT & ROCK WASHING OPERATIONS

Muddy River Restoration Project Project Description

SECTION STORM DRAINAGE TABLE OF CONTENTS

STORMWATER POLLUTION PREVENTION PLAN TEMPLATE. 1.0 SITE DESCRIPTION 1.1 Project Name and Location Date

DRAINAGE :: DRAINAGE CONCERN FREQUENTLY ASKED QUESTIONS

Soakage Trenches. A better way to manage stormwater. Thinking Globally and Acting Locally

SC-07 STORM DRAIN INLET PROTECTION

Transcription:

Appendix G Mosquito Control Guidelines This appendix presents the guidance for designing and maintaining stormwater treatment measures to control mosquitoes from ACCWP s Vector Control Plan. Project sponsors are responsible for incorporating in their treatment measure designs and maintenance plans the Vector Control Plan s design and maintenance guidance, which is presented below. G.1 Design Guidance for Mosquito Control The following design considerations were adapted from guidance prepared by the California Department of Health Services, 1 and are provided for project sponsors to use when selecting, designing, and constructing stormwater treatment measures. General Design Principles Preserve natural drainage. Better site design measures reduce the amount of stormwater runoff and provide for natural on-site runoff control. This will reduce the number of stormwater treatment measures required. In flat areas, where standing water may occur for more than five days under existing conditions, consider grading to make minor increases in slope to improve surface drainage and prevent standing water. Select stormwater treatment measures based on site-specific conditions. Designs that take into account site conditions tend to improve drainage and limit the occurrence of stagnant water. Careful consideration should be made before intermittently flooded stormwater treatment measures are selected for handling stormwater. Facilities that pond water temporarily (e.g., extended detention basins) should be designed to drain water completely within five days of a storm event. Avoid placement of extended detention basins and underground structures in areas where they are likely to remain wet (i.e., high water tables). The principal outlet should have positive drainage. 1 Metzger, Marco, Vector-Borne Disease Section, California Department of Health Services. Managing Mosquitoes in Stormwater Treatment Devices, 2004. APPENDIX G G-1

ALAMEDA COUNTYWIDE CLEAN WATER PROGRAM When a new stormwater treatment measure is being installed, consider selecting a type that does not require a wet pond or other permanent pool of water. Properly design storm drains. The sheltered environment inside storm drains can promote mosquito breeding. Pipes should be designed and constructed for a rate of flow that flushes the system of sediment and prevents water backing up in the pipe. Storm drains should be constructed so that the invert out is at the same elevation as the interior bottom to prevent standing water. Use grouted rock energy dissipaters instead of loose rock. In practice, many stormwater treatment measures, not only wet ponds, hold water for over five days, sometimes due to their outdated designs, and possibly due to improper construction and maintenance. To ensure that public health and safety are protected, the following suggestions should be considered for any structure that holds water for over five days: Select or design an alternative (or modified) device that provides adequate - pollutant removal and complete drainage in five days. This is the most reliable and cost-effective choice. Contact state or local public health or vector control agencies to determine whether local mosquito species and local factors may preclude rapid mosquito emergence, thus safely allowing water residence times to exceed five days. In some areas this may require a detailed study that should be funded by the soliciting party. General Access Requirements for Mosquito Control The following requirements are necessary to provide mosquito abatement personnel access to treatment measures for inspection and abatement activities. Design stormwater treatment measures to be easily and safely accessible without the need for special requirements (e.g., OSHA requirements for confined space ). If utilizing covers, include in the design spring-loaded or light-weight access hatches that can be opened easily for inspection. Provide all-weather road access (with provisions for turning a full-size work vehicle) along at least one side of large above-ground structures that are less than 25 feet wide. For structures that have shoreline-to-shoreline distances in excess of 25 feet, a perimeter road is required for access to all sides. Dry System Design Principles for Mosquito Control Structures should be designed so they do not hold standing water for more than five days. Incorporate features that prevent or reduce the possibility of clogged discharge orifices (e.g., debris screens). The use of weep holes is not recommended due to rapid clogging. PAGE G-2 APPENDIX G

STORMWATER TECHNICAL GUIDANCE Use the hydraulic grade line of the site to select a stormwater treatment measure that allows water to flow by gravity through the structure. Pumps are not recommended because they are subject to failure and often require sumps that hold water. Design distribution piping and containment basins with adequate slopes to drain fully and prevent standing water. The design slope should take into consideration buildup of sediment between maintenance periods. Compaction during grading may also be needed to avoid slumping and settling. Avoid the use of loose riprap or concrete depressions that may hold standing water. Avoid barriers, diversions, or flow spreaders that may retain standing water. Use mosquito net to cover sand media filter sump pumps. Use aluminum smoke proof covers for any vault sedimentation basins. Properly design storm drain measures. The sheltered environment inside storm drains can promote mosquito breeding. Pipes should be designed and constructed for a rate of flow that flushes the system of sediment and prevents water backing up in the pipe. Sumps, Wet Vaults, and Catch Basin Design Principles for Mosquito Control Completely seal structures that retain water permanently or longer than five days to prevent entry of adult mosquitoes. Adult female mosquitoes may penetrate openings as small as 1/16 inch (2 mm) to gain access to water for egg laying. Screening (24 mesh screens) can exclude mosquitoes, but it is subject to damage and is not a method of choice. If covers are used, they should be tight fitting with maximum allowable gaps or holes of 1/16 inch (2 mm) to exclude entry of adult mosquitoes. Gaskets are a more effective barrier when used properly. Any covers or openings to enclosed areas where stagnant water may pool must be large enough (2 feet by 3 feet) to permit access by vector control personnel for surveillance and, if necessary, abatement activities. If the sump, vault, or basin is sealed against mosquitoes, with the exception of the inlet and outlet, use a design that will submerge the inlet and outlet completely to reduce the available surface area of water for mosquito egg-laying (female mosquitoes can fly through pipes). Creative use of flapper or pinch valves, collapsible tubes and brush curtains may be effective for mosquito exclusion in certain designs. Design structures with the appropriate pumping, piping, valves, or other necessary equipment to allow for easy dewatering of the unit, if necessary. Wet Ponds And Wetlands Design Principles for Mosquito Control If a wet pond or constructed, modified, or restored wetland must be built, appropriate and adequate funds must be allocated to support long-term site maintenance as well as routine monitoring and management of mosquitoes by a qualified agency. APPENDIX G PAGE G-3

ALAMEDA COUNTYWIDE CLEAN WATER PROGRAM Long-term management of mosquitoes in wet ponds and wetlands should integrate biological control, vegetation management and other physical practices, and chemical control as appropriate. Provide for regular inspection of sites for detection of developing mosquito populations. Local factors may influence the overall effectiveness of certain approaches for mosquito reduction. Wet ponds and wetlands should maintain water quality sufficient to support surfacefeeding fish such as mosquito fish (Gambusia affinis), which feed on immature mosquitoes and can aid significantly in mosquito control. If large predatory fish are present (e.g., perch and bass), mosquito fish populations may be negatively impacted or eradicated. In this case, careful vegetation management remains the only nonchemical mosquito control system. Where mosquito fish are not allowed, careful vegetation management remains the only nonchemical mosquito control system. Other predators such as dragonflies, diving beetles, birds, and bats feed on mosquitoes when available, but their effects are generally insufficient to preclude chemical treatment. Perform routine maintenance to reduce emergent plant densities. Emergent vegetation provides mosquito larvae with refuge from predators, protection from surface disturbances, and increased nutrient availability while interfering with monitoring and control efforts. Whenever possible, maintain wet ponds and wetlands at depths in excess of 4 feet to limit the spread of invasive emergent vegetation such as cattails (Typha spp.). Deep, open areas of exposed water are typically unsuitable for mosquito immatures due to surface disturbances and predation. Deep zones also provide refuge areas for fish and beneficial macroinvertebrates should the densely vegetated emergent zones be drained. Build shoreline perimeters as steep and uniform as practicable to discourage dense plant growth. Use concrete or liners in shallow areas to discourage unwanted plant growth where vegetation is unnecessary. Eliminate floating vegetation conducive to mosquito production, such as water hyacinth (Eichhornia spp.), duckweed (Lemna and Spirodela spp.), and filamentous algal mats. Make shorelines accessible to maintenance and vector control crews for periodic maintenance, control, and removal of emergent vegetation, as well as for routine mosquito monitoring and abatement procedures, if necessary. Improve designs of permanent pools. Minimize shallow depths and increase circulation in ponds. Permanently flooded measures should be stocked with native Gambusia minnows to foster biological predation on mosquito larvae. Do not use stormwater structures to meet endangered species mitigation requirements. Aquatic habitat for endangered species should not be created near areas populated by humans. PAGE G-4 APPENDIX G

STORMWATER TECHNICAL GUIDANCE G.2 Maintenance Guidance for Mosquito Control Routine and timely maintenance is critical for suppressing mosquito breeding as well as for meeting local water quality goals. If maintenance is neglected or inappropriate for a given site, even structures designed to be the least mosquito friendly may become significant breeding sites. Although general principles of vector control are described here, maintenance guidelines for individual treatment measures are often site-specific. The maintenance principles given below are intended to reduce the mosquito population. These principles should be incorporated, as appropriate, in maintenance plans developed for stormwater treatment control measures and in the ongoing maintenance and inspection of treatment measures. General Maintenance Principles With the exception of certain treatment control measures designed to hold permanent water, treatment measures should drain completely within five days to effectively suppress vector production. Any circumstances that restrict the flow of water from a system as designed should be corrected. Debris or silt build-up obstructing an outfall structure should be removed. Under drains and filtration media should be inspected periodically and cleaned out or replaced as needed. Conduct maintenance activities regularly, in accordance with a municipality-approved maintenance plan. Vegetation Management Maintenance Principles Conduct annual vegetative management, such as removing weeds and restricting growth of aquatic vegetation to the periphery of wet ponds. Remove grass cuttings, trash and other debris, especially at outlet structures. Avoid producing ruts when mowing (water may pool in ruts). Dry System Maintenance Principles for Mosquito Control Extended detention basins are usually designed to detain water for 40 or 48 hours. If they detain water for longer than five days, they are poorly maintained. If a detention basin has been installed at an inappropriate location (e.g., on a site where the water table is too close to the surface), and if elimination or modification of the system isn t possible then mosquitoes must be controlled with larvicides. The larvicide operation, in order to be effective, must be supported by a quality inspection program. Larvacides should only be applied by licensed pesticide applicators. APPENDIX G PAGE G-5

ALAMEDA COUNTYWIDE CLEAN WATER PROGRAM Underground Structure Maintenance Principles for Mosquito Control Prevent mosquito access to underground treatment control measures that may have standing water (i.e., seal openings that are 1/16-inch in diameter or greater). Provide vector control agencies access to underground measures that may have standing water. Infiltration and Filtration Device Maintenance Principles for Mosquito Control Infiltration trenches and sand filter structures should not hold water for longer than 24 hours. If they retain water for longer than 48 hours, they are poorly maintained. PAGE G-6 APPENDIX G