VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer



Similar documents
VALIANT COMMUNICATIONS LIMITED

ORION TELECOM NETWORKS INC. T1

VALIANT COMMUNICATIONS

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Loop-IP6700 TDMoEthernet

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

TDMoEthernet. Description

DXC Family. Multiservice Access Node FEATURES

F2400 FOM II Series Fiber Optic Modem Technical Manual

Loop-IP6700 TDMoEthernet

VALIANT COMMUNICATIONS LIMITED

Loop-IP6702 TDMoEthernet

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

E1-GSM RION ORION TELECOM NETWORKS INC. E1 Channel Bank with 30 X GSM Wireless Interface(s) TELECOM NETWORKS

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Chassis, Power Supply, and Element Management

ORION TELECOM NETWORKS INC.

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Uninterruptible Power Supply

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Compact SDI Routers KUMO 1604 KUMO 1616 KUMO CP

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-IP6510 Multiple WAN Router/Bridge

Intraplex T1 CrossConnect System & Server Installation and Operation Manual Issue 1.1, December 2001

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

FCD-E1E Managed E1 and Fractional E1 Access Device

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Optimux-134, Optimux-125

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Cisco 7816-I5 Media Convergence Server

Setting Up and Testing the MAX Hardware

DataSMART 681, 696 and 698

Optimux-34, Optimux-25

Dialogic DSI Signaling Web Services Based on Dialogic DSI SS7G41 Signaling Servers

Product Overview. Features CHAPTER

T3 Mux M13 Multiplexer

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Optimux-134, Optimux-125

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

DXC-8R/10A/30 Multiservice Access Nodes

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

24-Port Channelized E1/T1 Line Card Overview

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

3500/22M Transient Data Interface

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Communication Unit 560CMU05 Data sheet

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

Figure 1 - T1/E1 Internet Access

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

How To Run An Nport I5000A Device Server

PN5212/PN5320/PN7212/PN7320

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

INSTRUCTION MANUAL MODEL PCD-88

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

SNMP Management of KIV-19s using the. TELEGRID KIV-19 Remote SNMP Proxy (KRSP TM )

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

IPM-T1 T1/DS1 over IP Multiplexer

Long Range Ethernet Extender

VALIANT COMMUNICATIONS LIMITED

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

IPmux-1E TDM Pseudowire Access Gateway

Ethernet Link SGI-2424

NortechCommander Software Operating Manual MAN R6

Dialogic I-Gate 4000 SIP Gateway

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Cisco Communication Media Module

G-TAP A Series // Data Sheet

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Advantium 2 Plus Alarm

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

TrueAlarm Fire Alarm Systems

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Adit 3200 QUICK START GUIDE

Chapter 4 T1 Interface Card

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

CIC-50. T1/E1 G.703 Interface Converter Installation and Operation Manual (Accessory Product for use only with Comtech EFData CDM-550/550T Modems)

Ethernet Link SGI-4844F

Infinity C DC to DC Power System

Automatic AES Change-Over

Nokia IP Security Platforms Technical Specifications Guide Nokia Enterprise Solutions

GigaVUE-420. The Next Generation. Data Access Switch. Gigamon Systems. Intelligent Data Access Networking

300Mbps Wireless N Gigabit Ceilling Mount Access Point

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

Transcription:

VCL-MX Version 6 - T 20Mbps Voice & Data Multiplexer VCL-MX Version 6 DXC 80 T, 20Mbps Digital Access Cross Connect Switch System Guide Copyright: Valiant Communications Limited - 202

Warranty This Valiant product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Valiant will, at its discretion, either repair or replace products, which prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by Valiant. The buyer shall prepay shipping charges to Valiant and the company shall pay shipping charges to return the product to the buyer. However, the buyer shall pay all the shipping charges, duties and taxes for products returned to Valiant from another country. Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the buyer. The buyer-supplied firmware or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product or improper site preparation or maintenance. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Valiant shall not be liable for any direct, indirect, special, incidental or consequential damages, whether based on contract or any legal theory. Notice This manual contains information that is proprietary to Valiant Communications Limited. No part of this publication may be reproduced in any form whatsoever without prior written approval by Valiant Communications Limited. Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment, which could pose a safety hazard. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this instrument. No adjustment, maintenance or repairs should be performed by either the operator or the user. Copyright: Valiant Communications Limited - 202 2

Index S. No. Particulars Page No. Product Overview 4 2 Key Features and Highlights 4 3 System Access, Control and Management Options 4 4 OAM: Operation and Management Ports 5 5 Security and Protection 5 6 System Overview and Architectural Details 5 7 Chassis / System Backplane 5 8 Timing (Clock) Synchronization 5 9 System Management 6 0 Status Monitoring 7 Alarm Status and Monitoring 7 2 LED Indication 7 3 External Alarm 7 4 Technical Specifications 7 5 Control Card 7 6 OAM Management Interface Card 8 7 T Interface Card 8 8 Power Supply Card 9 9 Power Consumption 9 20 Environmental 9 2 Dimensions 9 22 Ordering Information 0 23 Support Copyright: Valiant Communications Limited - 202 3

Product Overview The VCL-MX Version 6 DXC 80 T, 20Mbps Digital Access Cross Connect is a modular switch which may be scaled from 8 T Ports to up to 80 T Ports. The VCL-MX Version 6, T DACS (T DXC) offers full cross-connect functionality to cross-connect between 64Kbps time-slots (DS-0s), "n"x64kbps consecutive DS-0s and Fractional T channels to full T channels. The VCL-MX Version 6 DXC 80 T, 20Mbps Digital Access Cross Connect Switch, occupies 6U high (264 mm) rack-space and is a complete 9-inch standalone unit that provides a 64Kbps time-slot (DS-0) cross-connect fabric for up to 80 T ports. This product offers + -48V DC Power Supply Redundancy, + Control Card and Processor Redundancy, + Cross-Connect (TSI) Redundancy, + Timing (Synchronization Clock Circuitry) Redundancy. This DXC offers user selectable clock / timing synchronization priority. The Dual Power Inputs allow the equipment to be powered from two separate power sources. AC input external adapter is an optional for AC mains operation. Key Features and Highlights 20Mbps, 80 T fully non-blocking cross-connect at 64Kbps (DS-0) level (920 DS-0 any to any time-slot cross-connect) Scalable from 8 T Ports to 80 T Ports + Control Card Processor Redundancy + Cross-Connect / TSI Redundancy + Timing (Synchronization Clock) Redundancy + -48V DC Power Supply Redundancy (Dual Power Input allows the equipment to be powered from two separate -48V DC sources Bit Error Rate (BER) monitoring BER thresholds to generate BER alarms automatically whenever alarm limits are exceeded Telnet remote access. SSH for secured remote access SNMP traps Maintains Access Security Log USB and RS232, Interface for local connection through the serial interface to the "Network Control and Management Software User Selectable Internal, External and Loop-timed clock synchronization priority options Local and remote loopback facility. System Access, Control and Management Options Telnet SSH CLI Control Interface (HyperTerminal or VT00) SNMP V2 Traps (MIB File provided) GUI (Graphical User Interface) Copyright: Valiant Communications Limited - 202 4

OAM: Operation and Management Ports RS232 Serial Port USB COM Port 0/00BaseT Ethernet for remote access. Security and Protection Secured Access via SSH V2 Password Protection: Password Protection in compliance with the mandatory clauses of the GR-85-CORE-2 specifications for secured access control. Logging: Maintains a log of all successful and un-successful attempts. Logged information includes the ID and the IP address of the accessing entities. Alerts the administrator if the un-successful logging attempts exceed 3 Security Audit: All access logs for up to 30 days are maintained for security audit purposes Security log entry of any request or activity including that user-id (including IP address, if applicable), to establish user accountability Report Generation / Audit Trail Security Administration. System Overview and Architectural Details VCL-MX Version 6, is a scalable DXC which may be used to cross-connect at DS-0 (64Kbps time-slot level) from 8 T Ports to 80 T Ports (20Mbps). The VCL-MX Version 6 DXC has a multi-slot chassis with TDM backplane. In the chassis, there are ten (0) T interface card slots. Each T Interface Card has 8 T Ports. Two slots are reserved for + redundant control cards which includes the redundant cross connect, processor, TSI and clock synchronization / timing functions. One dedicated slot exists for an OAM card and two slots for + redundant power supply cards. Chassis / System Backplane All connections are made at the rear of the chassis, providing interconnections between the various plug-in cards and to the network. VCL-MX Version 6-80 T, 20Mbps Digital Access Cross Connect Switch supports high-density T interface cards. An extensive set of alarms, for easy maintenance are provided in the system. Timing (Clock) Synchronization Timing Options Synchronization Sources Default Option Internal Clock, Loop-Timed Clock, External Clock. User selectable synchronization priority Internal Clock, span clock timing derived from incoming T links (Loop-Timed), External Clock, 75 Ohms (TTL),.544 Mbps (00 Ohms Bits clock) Internal Clock Copyright: Valiant Communications Limited - 202 5

System Management VCL-MX Version 6-80 T, 20Mbps Digital Access Cross Connect Switch offers a variety of management options. The equipment may be configured using CLI (English text) commands, or a GUI (Graphical User Interface). The management and configuration commands may be executed from a VT00 terminal, Windows HyperTerminal, any DOS based system, Linux or UNIX based system, or Telnet (remote configuration and management). The equipment provides a wide choice of access ports for connecting to and executing management and configuration commands through its OAM Card. The OAM card provides: a) COM Port (RS232 Serial Port). b) USB Port c) 0/00BaseT Ethernet Port (each multiplexer may be assigned an IP address and connected to a LAN / IP network for remote access and management through the 0/00BaseT Ethernet Port for out-of-band configuration, management and access). Copyright: Valiant Communications Limited - 202 6

The OAM card supports: a) Telnet b) SSH c) SNMP, V2 d) Additionally, a Windows based GUI (Graphical User Interface) for easy configuration, management and access. The VCL-MX has an effective, CLI (text) and GUI based "Network Management Interface", which may be used for configuring and monitoring multiple systems from a single central location. Status Monitoring Synchronization Clock Selection Status of alarms Enabled/Disabled status of.544 Mbps T ports Monitoring the 80 Port T DACS status and configuration Monitoring of T Link status: LOS, LOF, AIS, RA. Alarm status and monitoring Loss of incoming signal at all.544 Mbps T Ports Configuration error alarm. LED indications to 80 T Ports LED indicators 5V DC present -48V DC present Configuration error. External Alarm - Contact Closures Alarm relay Type - form "C Technical Specifications: DACS Control Card - Processor, Timing and TSI Card: (Part No. VCL-MX-500-DXC) Control Card Redundancy Processor Timing and TSI Yes + Redundant ARM7 Self Learning Self Healing Automatic Fail-Over and Recovery + Redundant Self Learning Self Healing Automatic Fail-Over and Recovery Copyright: Valiant Communications Limited - 202 7

OAM - Management Interface Card (Part No. VCL-OAM-490-5.0) COM Port (RS232 Serial Port) USB Port 0/00BaseT Ethernet Port - Each multiplexer may be assigned an IP address and connected to a LAN / IP network for remote access and management through the 0/00BaseT Ethernet Port for out-of-band configuration, management and access Telnet SSH SNMP, V2 Windows based GUI (Graphical User Interface) for easy configuration, management and access. T Interface Card: (Part No. VCL-MX-520-T-5.0) Maximum number of interfaces Number of Interfaces per T Interface Card Connectors 80 T Interfaces with full capability to cross connect at DS-0, 64Kbps time-slot level, as well as to inter-connect to voice and digital data services between 80 incoming T Ports (i.e. 80 separate T Links, 920 DS-0 any to any time-slot crossconnect) 8 T Interfaces with full capability to cross connect at DS-0, 64Kbps time-slot level as well as to inter-connect to voice and digital data services between 80 incoming T Ports (i.e. 80 separate T Links) DB-25 / RJ-45 / RJ-48C Conformity (electrical) ITU-T G.703 Frame Structure As per ITU (CCITT) G.704 Framing Options Line Coding Line Rate Nominal Impedance D4, ESF (Selectable) AMI, B8ZS (Selectable).544 Kbps ± 50 ppm 00 Ohms Jitter Tolerance ITU-T G.823, ITU-T.43 Monitoring Connection Line Quality Loss of Signal (LOS), Loss of Frame (LOF), All Ones Alarms (AIS), RA (Remote Alarm). Copyright: Valiant Communications Limited - 202 8

Power Supply (Part No. VCL-MX-50) Input DC Voltage -48V DC (nominal) Range of Input -36V to -72V DC Output Voltage 5V filtered -48V (for terminal cards) Full Load Current Rating 4A at 48V DC Input Voltage Reversal Protection Provided in the Card Over Current Protection 4A at 48V DC Short Circuit Protection Current limit 4A. Recovers on removal of short Efficiency at Full Load > 9% Power Consumption Maximum Power Consumption 90 watts Environmental Temperature -0 C to + 60 C Humidity 95% R.H. (non-condensing) Altitude Upto 9,000 feet Dimensions Height Width Depth Weight 266 mm (9 6U high) 482 mm 270 mm 7 Kgs Regulation Compliance Meets CE requirements Complies with FCC Part 68 and EMC FCC Part 5 Class 2 Safety - ULI 459 Issue 2 Operation ETS 300 09 Class 3.2 Storage ETS 300 09 Class.2 Transportation ETS 300 09 Class 2.3 Protection Central Office Terminal and Remote Terminal are protected against power surges and transients occurring from lightning and electric induction as per CCITT Rec. Table I/K-20 towards line side. Copyright: Valiant Communications Limited - 202 9

Ordering Information VCL-MX Version 6, Upto 80 T, 20Mbps DACS / DXC [Core / Common Equipment] Sr. No. Part Number Product Description Qty. VCL-MX-500-DXC DACS Control Card Central processor, cross-connect and system control Card may be used in a + redundant Configuration Note: Please order 2 numbers for + redundancy 2 VCL-OAM-490-5.0 Management Card [RJ45, DB9F COM, USB] OAM - Operations and Management Card for connecting the multiplexer to be managed in a LAN - allows the USER to assign a unique IP address to each multiplexer connected in a LAN to be managed from a single point. Telnet, SNMP (V2) 3 VCL-MX-506 4 VCL-MX-50 9" Shelf 6U High (Sub-rack) fitted with DB25F Connectorized Backplane Max. Ten (0) traffic slots meant for tributary cards (line cards) (-) 48VDC Input Power Supply Card may be used in a + redundant Configuration Note: Please order 2 numbers for + redundancy VCL-MX Version 6, Upto 80 T, 20Mbps DACS / DXC [User Configurable Interfaces] Sr. No. Part Number Product Description Qty. VCL-MX-520-T-5.0 8 T Interface Card Full capability to cross connect at DS-0, 64Kbps time-slot level as well as to inter-connect to voice and digital data services between 80 incoming T Ports (i.e., 80 separate T Links, 920 DS-0 any to any time-slot cross-connect). (0 Cards / 80 Ports (Max) per Chassis) 0 Copyright: Valiant Communications Limited - 202 0

VCL-MX Version 6, Upto 80 T, 20Mbps DACS / DXC [Cables & Accessories] Sr. No. Part Number Product Description Qty. VCL-505-TER- DB37F-RJ45F-6PP 6xE/T, DB37 [2 x DB37F] to RJ45 [6 x RJ45F] Termination Panel 9" Metal case U High Rack Mount Version with Hardware Set 0 2 VCL-505-TER- DB37F-RJ45F-32PP 32xE/T, DB37 [4 x DB37F] to RJ45 [32 x RJ45F] Termination Panel 9" Metal case U High Rack Mount Version with Hardware Set 3 VCL-505-TER- DB37F-RJ45F-48PP 48xE/T, DB37 [6 x DB37F] to RJ45 [48 x RJ45F] Termination Panel 9" Metal case U High Rack Mount Version with Hardware Set 4 VCL-HRNS 264-4EO E/T 4 Port Connectorized Cable [DB25M-Open] [ cable each 4 Port E/T card] 0 5 VCL-HRNS 268-6EY37M E/T 8 Port Y Connectorized Cable [2xDB25M-DB37M] [ cable each 8 Port VCL-505-TER-DB37F-RJ45F-6PP] 0 6 UMIKitMXV6DXC System Core Cables, Installation Accessories, Documentation, System User Manual, Systems User Manual Disk, etc [Set] Technical specifications are subjects to changes without notice. Revision. May 24, 202. Copyright: Valiant Communications Limited - 202