GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: gree@gree.com.cn http://www.gree.com.cn Heat Pump Water Heater System GREE, MAKING BETTER AIR CONDITIONERS
Heat Pump Water Heater System
HOME-GMV Cooling Heating Hot water Gree HOME-GMV unit perfectly unites DC variable frequency technology with heat recovery technology and achieves joint operation of central air-conditioning system and central water-heating system. It is declared by industrial authorities a comprehensive air-conditioning and water-heating solution for modern homes. + + Hot Wind Waste Heat Discharge Cold Wind Cooling Waste Heat Recovery Water Tank Cold Wind Cooling Three in one Traditional Air Conditioners Large heat energy discharge into air during cooling. It wastes for nothing. Home-GMV Recycle waste heat to heat the cool water and get the free hot water. 2 Unit Performances Its unique five-mode operation (cooling, heating, water-heating, cooling + water-heating and heating + water heating) is a breakthrough in traditional heat recovery technology where heating and water-heating cannot be GREE HOME-GMV achieved at the same time. By DC inverter technology, the compressor regulates output according to the workload for better energy performance. Thanks to heat recovery technology, free hot water is produced in cooling operation, achieving the highest energy performance of 6.6, the best in the industry. The multi-unit arrangement with one outdoor unit connected to several indoor units of various designs suits Grade A Energy Performance DC Inverter Multi Air-Conditioner perfectly your indoor decoration. The combination of air-conditioner with water-heater saves precious floor space. Extremely long connecting tubes adapt well to various apartment layouts. The 10-16 cooling output capacity is suitable for 80-200sqm apartments and multi-floor villas. HOME-GMV Wall-Type Unit Floor Ceiling 4-side Ceiling Air Outlet Air Duct Outlet G-4 Air-Source Heat Pump Water Heater 01 02
Unit Advantages 2. Intelligent Experience Carefree Living 1. Double-Way Energy Saving [ Heat Recovery + DC Inverter = Higher Energy Performance ] DC Inverter Technology World-brand dual-rotor DC inverter compressor ensures optimal output and high system performance. With stepless power regulation technology, the DC variable frequency compressor achieves digital stepless output regulation between 20Hz-80Hz. The features of 180 degree current output waveform, small startup current, small torque pulse and free speed regulation between 900-6600rpm enable the system to meet the temperature requirements of various circumstances, save power consumption and ensure comfortable use. New compressor structure. Increast the performance of median frequency. The new DC motor increase the performance of low frequency Five-Mode Operation Cooling: Quick cooling in -5~48 degree Celsius outdoor temperature creates a cool and fresh world in the hot suer. Heating: Strong heating in -15~24 degree Celsius outdoor temperature creates a warm world in the cold winter. Water heating: Comfortable, safe and healthy living water is provided. Cooling + Water heating: Flexible energy saving process embodies to the best the heat recovery design. Heating + Water heating: Different from conventional air-conditioning water heating system, the heating and water heating functions here can be put into use at the same time. Traditional Compressor Traditional DC Inverter compressor Gree DC Inverter compressor User-Friendly Control Indoor temperature Large fluctuate Indoor temperature Indoor temperature Flexible and varied control system caters to different customers. Setting temperature Setting temperature Setting temperature Too cold Temperature equation Time Time Time Compressor On Off On Off On Rated cooling capacity Inverter compressor On Off Rated cooling capacity Digital DC inverter compressor Rated cooling capacity On Frequently turn on and turn off cause large temperature fluctuate. The cooling speed is slow and the temperature fluctuate is large. The inverter technology with high-power and high energy efficiency not only create comfortable living circumstance, but also save energy. wired controller remote controller centralized controller Heat Recovery Technology Optional running mode memory enables the air-conditioner to restore to its previous running mode when it recovers from a power failure. The user, The expertly designed refrigerating system heat recovery technology and exhaust heat recovery technology have been Heat recovery Heating water Electric energy 1 Q1 however, may turn on/off this memory function. granted China invention and application patents. During cooling operation, the condensing heat is recovered and reused to heat living water. Therefore, free hot water is produced when the refrigerating system is on. Heat energy 3.8 Q2 Cooling capacity 2.8 Q3 Indoor cooling Powerful automatic control enables the system to run unattended in a variety of working conditions, e.g., day or night, indoor or outdoor, store water in night use water in day The comprehensive energy performance of 6.6, the highest in the industry. Home-GMV The comprehensive EER of Home-GMV reaches 6.6 which save more money. fine or cloudy, windy or raining, supplying hot living water 24 hours a day without interruption. 03 04
3. Comfortable Enjoy a Wonderful Life Indoor Unit Suitable Water Temperature Indoor units of various designs are available to suit your indoor furnishings. Hot water from central air-conditioning system with free temperature setting between 35-65 degrees Celsius meets the user needs for various purposes. Quick water heating in large volume ensures hot water supply to different locations. Electronic expansion valve guarantees precise automatic temperature regulation and constant water temperature. Cassette Unit Square panel in same size for easy installation. Air supply in different directions with 30-75 degree sweep for even temperature distribution. Lasting filter cleaning and high-lift condensing pump. Hot water Cool water Lavabo Bathtub Kitchen Air Duct Unit 4. Fashionable Tells Your Class Flexible and easy to install in type-l, type-u and large rooms. Designed with fresh air baffle for fresh air introduction. Air-conditioner and water heater only need one outdoor unit, which is placed in the balcony, on the roof or in a specific outdoor unit bay. This system not only saves space but also avoids the damage to the house facing integrity due to the installation of many outdoor units. Wall-Type Unit Streamlined design for spaces without ceiling. Cold wind prevention design with multi-layer protection. Floor Ceiling Unit (Multi type: one outdoor unit plus multi indoor unit) (Single type: one outdoor unit plus one indoor unit) Floor ceiling type satisfies your more requirement for the space. 05 06
5. Safe Cares Your Concerns Parameters In-unit high and low voltage protection, compressor over current and over load protection as well as startup delay rule out any possibility of creepage, dry heating, ultra-high temperature, etc. The fact that no fuel duct or tank is used removes the risk of fuel leakage, fire hazard or explosion danger. After long winter without using the unit, by turns on the draw off valve to drain the water to avoids the frost crack of the sleeving inside the unit. 6. Convenient Facilitates Installation Work Primary refrigerant system and simple piping and wiring ensure easy and low-cost installation. Pressure water tank is adopted in the system and tap water pressure is exploited to drive hot water, saving such parts as circulating water pump, flow switch and water level gauge. Central Hot Water System Central Air Conditioners System GMV-Pds100W/Na-K GMV-Pds120W/Na-K GMV-Pds140W/Na-K GMV-Pds160W/Na-K Cooling/Heating 10.0/11.0 12.0/13.2 14.0/15.4 16.0/17.6 COP(Heating)* W/W 6.6 6.6 6.6 6.6 Rated water heating capacity 5.0 5.0 8.0 8.0 Water temperature 50(Default), 35~65(Adjustable temperature range) Noise db(a) 56 56 58 60 R410A charged volume 5.0 5.0 7.0 7.0 220~240V,1Ph,50Hz Rate power input Cooling/Heating 4.5/3.8 5.0/4.2 5.5/4.9 5.9/5.3 Water heating 2.0 2.0 3.0 3.0 Outline dimension (W D H) 950 340 1250 Package dimension (W D H) 1110 450 1370 1110 450 1370 1110 450 1370 1110 450 1370 Gas(AC) s Liquid(AC) Gas(Water) Liquid(Water) N.W./G.W 105/115 105/115 115/125 115/125 * This cop is tested under the mode of cooling+water heating. Water Tank Hydro-box Duct Type Indoor Unit Water Tank Total capacity of indoor units can be set to 50-120% of the outdoor unit capacity. GMV-Pds100W/Na-K GMV-Pds120W/Na-K The sum of the min. capacity of indoor units The sum of the max. capacity of indoor units 80 130 80 130 Dimension Water tank model Tank volume SXD250LC-K SXD300LC-K SXD350LC-K SXD400LC-K L 250 300 350 400 Outline (Diameter Ht) 540 1945 620 1600 620 1895 620 2125 Package (W D H) 625 630 1970 705 710 1645 705 710 1920 705 710 2150 Auxiliary electrical heater Rate power input 1.5 1.5 1.5 1.5 Waterpipes N.W./G.W Cool water inlet Hot water inlet 68/77 71/81 79/90 86/98 GMV-Pds140W/Na-K 80 160 GMV-Pds160W/Na-K 80 160 Outdoor unit, hydro-box and water tank matching: Hydro-Box GMV-Pds160W/Na-K GMV-Pds140W/Na-K GMV-Pds120W/Na-K GMV-Pds100W/Na-K The model of hydro-box RQD8GA-K Recoend tank capacity (L) SXD350LC-K or SXD400LC-K RQD5GA-K SXD250LC-K or SXD300LC-K Hydro-Box model RQD8GA-K RQD5GA-K Outline Dimension (W D H) 650 300 250 650 300 250 Package Dimension (W D H) 725 365 313 725 365 313 220~240V,1Ph,50Hz 220~240V,1Ph,50Hz Liquid Refrigerant side s Gas Water inlet Water side Water pump lift Water outlet meter 6 6 N.W./G.W 25/28 25/28 07 08
Duct unit Cassette unit Sound pressure level GMVL-R22P/NaB-K GMVL-R25P/NaB-K GMVL-R28P/NaB-K GMVL-R36P/NaB-K GMVL-R45P/NaB-K GMV-R22P/NaB-K GMV-R25P/NaB-K GMV-R28P/NaB-K GMV-R36P/NaB-K GMV-R45P/NaB-K Cooling 2.2 2.5 2.8 3.6 4.5 Heating 2.5 2.8 3.2 4.0 5.0 W 75 75 80 80 100 3 m /h 450 450 570 570 840 CFM 265 265 335 335 494 Pa 20/0 20/0 20/0 20/0 50/20 db(a) 37 37 39 39 40 Outline dimension W D H 870 680 260 870 680 260 870 680 260 870 680 260 980 736 266 Package dimension W D H 1012 780 315 1012 780 315 1012 780 315 1012 780 315 1068 766 320 Net Weight Standard Esp Cooling only 27 27 27 27 34 31 31 31 31 37 Gas Liquid 1/4 1/4 1/4 1/4 1/4 GMVL-R28T/Na-K GMVL-R36T/Na-K GMVL-R45T/Na-K GMVL-R50T/Na-K GMVL-R56T/Na-K GMVL-R63T/Na-K GMV-R28T/Na-K GMV-R36T/Na-K GMV-R45T/Na-K GMV-R50T/Na-K GMV-R56T/Na-K GMV-R63T/Na-K Cooling 2.8 3.6 4.5 5.0 5.6 6.3 Heating 3.2 4.0 5.0 5.8 6.3 7.0 W 35 35 35 35 35 35 3 m /h 680 680 680 680 1180 1180 CFM 400 400 400 400 695 695 Sound pressure level db(a) 37 37 37 37 39 39 Outline WxDxH 840x840x190 840x840x190 840x840x190 840x840x190 840x840x240 840x840x240 Main body Panel Cooling only Package WxDxH 960x960x257 960x960x257 960x960x257 960x960x257 960x960x310 960x960x310 Net weight 25 25 25 25 30 30 33 33 33 33 38 38 Outline WxDxH 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 Package WxDxH 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 Net weight 6.5 6.5 6.5 6.5 6.5 6.5 10 10 10 10 10 10 Gas Liquid 1/4 1/4 1/4 1/4 Sound pressure level GMVL-R56P/NaB-K GMVL-R71P/NaB-K GMVL-R90P/NaB-K GMVL-R112P/NaB-K GMVL-R140P/NaB-K GMV-R56P/NaB-K GMV-R71P/NaB-K GMV-R90P/NaB-K GMV-R112P/NaB-K GMV-R140P/NaB-K Cooling 5.6 7.1 9.0 11.2 14.0 Heating 6.3 8.0 10.0 12.5 15.0 W 240 240 360 360 500 3 m /h 1400 1400 2000 2000 2500 CFM 824 824 1177 1177 1471 Pa 60/30 60/30 80/40 80/40 100/50 db(a) 44 44 48 48 50 Outline dimension W D H 1112 756 300 1112 756 300 1425 756 300 1425 756 300 1463 756 300 Package dimension W D H 1245 785 360 1245 785 360 1514 785 360 1514 785 360 1555 810 345 Net Weight Standard Esp Cooling only 49 49 62 62 64 56 56 71 71 73 Gas Liquid GMVL-R71T/Na-K GMVL-R80T/Na-K GMVL-R90T/Na-K GMVL-R100T/Na-K GMVL-R112T/Na-K GMVL-R125T/Na-K GMV-R71T/Na-K GMV-R80T/Na-K GMV-R90T/Na-K GMV-R100T/Na-K GMV-R112T/Na-K GMV-R125T/Na-K Cooling 7.1 8.0 9.0 10.0 11.2 12.5 Heating 8.0 8.8 10.0 11.0 12.5 13.5 W 35 35 60 60 60 60 3 m /h 1180 1180 1860 1860 1860 1860 CFM 695 695 1095 1095 1095 1095 Sound pressure level db(a) 39 39 40 40 40 40 Outline WxDxH 840x840x240 840x840x240 840x840x320 840x840x320 840x840x320 840x840x320 Main body Panel Cooling only Package WxDxH 960x960x310 960x960x310 960x960x394 960x960x394 960x960x394 960x960x394 Net weight 30 30 38 38 38 38 38 38 46 46 46 46 Outline WxDxH 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 950x950x60 GMVL-R140T/Na-K GMV-R140T/Na-K Package WxDxH 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 1040x1025x115 Net weight 6.5 6.5 6.5 6.5 6.5 6.5 6.5 10 10 10 10 10 10 10 Gas Liquid 14.0 14.5 60 1860 1095 40 840x840x320 960x960x394 38 46 950x950x60 Cassette unit Main body Panel Cooling Heating Sound pressure level Outline WxDxH Package WxDxH Net weight Outline WxDxH Package WxDxH Net weight Gas Liquid W 3 m /h CFM db(a) GMV-R22T/NaA-K GMV-R28T/NaA-K GMV-R36T/NaA-K GMV-R45T/NaA-K 2.2 2.8 3.6 4.5 2.5 3.2 4.0 5.0 12 12 12 12 600 600 600 600 353 353 353 353 47 47 47 47 570 570 230 848 728 310 20 570 570 230 848 728 310 20 570 570 230 848 728 310 20 570 570 230 848 728 310 20 27 27 27 27 650 650 50 650 650 50 650 650 50 650 650 50 730 670 102 730 670 102 730 670 102 730 670 102 5 5 5 5 10 10 10 10 1/4 1/4 1/4 1/4 Floor Ceiling unit Sound pressure level Net Weight Cooling only GMVL-R28Zd/Na-K GMVL-R36Zd/Na-K GMVL-R50Zd/Na-K GMVL-R71Zd/Na-K GMVL-R90Zd/Na-K GMVL-R112Zd/Na-K GMVL-R125Zd/Na-K GMV-R28Zd/Na-K GMV-R36Zd/Na-K GMV-R50Zd/Na-K GMV-R71Zd/Na-K GMV-R90Zd/Na-K GMV-R112Zd/Na-K GMV-R125Zd/Na-K Cooling 2.8 3.6 5.0 7.1 9.0 11.2 12.5 Heating 3.2 4.0 5.8 8.0 10.0 12.5 13.5 Gas Liquid W 10 10 40 100 150 180 180 3 m /h 550 600 700 1170 2100 2200 2300 CFM 324 353 412 689 1236 1294 1353 db(a) 43 44 50 48 51 54 55 Outline dimension WxDxH 840 238 695 840 238 695 840 238 695 1300 188 600 1590 238 695 1590 238 695 1590 238 695 Package dimension WxDxH 1035 295 805 1035 295 805 1035 295 805 1514 248 724 1814 330 830 1814 330 830 1814 330 830 28 28 28 34 44 44 44 37 37 37 38 53 53 53 1/4 1/4 1/4 09 10
AIR SOURCE WATER HEATER Mounted unit s Cooling only GMVL-R22G/NaB-K GMVL-R28G/NaB-K GMVL-R36G/NaB-K GMVL-R45G/NaB-K GMV-R22G/NaB-K GMV-R28G/NaB-K GMV-R36G/NaB-K GMV-R45G/NaB-K Modular Circulating Water Heater Cooling 2.2 2.8 3.6 4.5 Heating 2.5 3.2 4 5 W 14 14 22 22 Nominal () Refrigerant Name Power Supply (V, Ph, Hz) Appearance Controller m 3 /h 360 360 500 500 CFM 212 212 294 294 Sound pressure level (H/L) db(a) 37/28 37/28 43/28 43/28 Outline dimension WxDxH 770 190 250 770 190 250 830 189 285 830 189 285 Package dimension WxDxH 955 330 272 955 330 272 1006 385 265 1006 385 265 Net Weight 8 8 11 11 14.3 14.3 15.8 15.8 Gas Liquid 1/4 1/4 1/4 1/4 18 R22 GRS-Cm18/A-M 380,3,50 36 R22 GRS-Cm36/A-M 380,3,50 65 R22 GRS-Cm65/A-M 380,3,50 Single Circulating Water Heater Cooling only GMVL-R50G/NaB-K GMVL-R56G/NaB-K GMVL-R71G/NaB-K GMVL-R80G/NaB-K GMV-R50G/NaB-K GMV-R56G/NaB-K GMV-R71G/NaB-K GMV-R80G/NaB-K Cooling 5.0 5.6 7.1 8.0 Heating 5.8 6.3 8 9 Nominal () Refrigerant Name Power Supply (V, Ph, Hz) 3.5 R22 GRS-C3.5/A1-K 220-240,1,50 Appearance Controller Sound pressure level (H/L) 220-240V,1Ph, 50Hz W 20 20 26 26 m 3 /h 700 750 1200 1200 CFM 412 441.5 706 706 db(a) 45/40 45/40 49/42 49/42 5.0 R22 GRS-C5.0/A1-K 220-240,1,50 7.2 R22 GRS-C7.2/A1-K 220-240,1,50 3.8 5.0 R134a R134a GRS-C3.8/NbA-K GRS-C5.0/NbA-K 220-240,1,50 220-240,1,50 AIR SOURCE WATER HEATER Outline dimension WxDxH 1020 228 310 1020 228 310 1178 227 326 1178 227 326 9.0 R410A GRS-C9/Na-M 380-415,3,50 Package dimension WxDxH 1178 325 390 1178 325 390 1365 417 333 1365 417 333 Net Weight 15.5 15.5 17.5 17.5 16.0 R410A GRS-C16/Na-M 380-415,3,50 20.5 20.5 23 23 Gas Liquid 1/4 And Water Tank Matching Nominal Volume (L) Name Appearance GRS-C3.5/A1-K 150 200 SX150LC/B1-K SX200LC/B1-K Non Electric Heater GRS-C5.0/A1-K 250 SX250LC/B1-K 300 SX300LC/B1-K AIR SOURCE WATER HEATER GRS-C7.2/A1-K 350 SX350LC/B1-K 400 SX400LC/B1-K With Electric Heater GRS-C3.8/NbA-K GRS-C5.0/NbA-K 150 SXD150LC-K 200 SXD200LC-K 250 SXD250LC-K 300 SXD300LC-K 11 12
Description Standard Features Air source is a kind of low-grade energy which exists widely and can be equally supplied and freely applied. Upgraded by use of heat pump circulation, it can potentially developed to a new kind of energy saving and environment friendly technology with practical value. Air source heat pump water heater by use of heat pump principle will consume a part of electric energy for compensation and obtain heat from low-grade energy (low-temperature air source) around. The heat will be sent to condenser and released to high-temperature heat source to generate hot water. With the same working principle as heat pump water heater, heat pump air conditioner obtains heat from natural environment which will be supplied to indoor air, but heat pump water heater heats domestic water by this part of heat, so it's EER is at least 2 times higher than conventional electric water heater. water heater is kind of high efficiency, energy saving and environment friendly product. unit usually consists of compressor, water side heat exchanger, air side heat exchanger, throttling device, high/low pressure accumulator and so on. And air source heat pump water heater consists of heat pump unit, insulated water tank, water pump, other relative pipeline valves, etc. conversing device. For example, electric water heater only transfers electric energy to hot water and gas water heater transfers heat energy by burning natural gas to hot water. Gree air source water heater not only transfers electric energy to hot water but also absorbs heat energy in air, which will be transferred to hot water. So efficiency of it can reach up to 460%, i.e. 1 electric energy can generate 4.6 heat energy. High efficiency and energy saving Conventional water heater is just an energy- It consumes electric energy which will generate about 4.6 times heating energy to heat water.the energy consumption is one fourth of electric water heater and one third of gas water heater with the same capacity. Easy Installation and Maintenance The unit can be installed on balcony, rooftop, yard, and basement and so on, no special machine room needed buy any place where without direct sunlight. Intelligent self-diagnose system is provided for easy maintenance. Hot water 4.6 Q3 Electric energy 1 Q1 AIR SOURCE WATER HEATER Heat absorbing 3.6 Q2 Air absorbs heat Compared with the similar type of products, 36 and 65 units with upper side air supply are more compact. Compressor High temperature High-temperature hot water Cold air Heat exchanger Low temp Hot air Expansion valve Water side heat exchanger Heat-retaining water tank High-temperature hot water Hot water user Comfortable and reliable Accurate water temperature Electronic expansion valve, applying for patent by Gree exclusively, is used in air source water heater to ensure auto adjustment of throttling degree according to change of ambient Cold water and water temperature. Water temperature within 35~60 can be adjusted casually(default 50 ). Water temperature deviation 1, so it is comfortable and accurate. 13 14
Constant water temperature Water temperature of water tank keeps even and constant.there is not any trouble of unreliable water temperature. Auto cleaning, healthy on every day The unit with cleaning function can automatically clean itself. Water tank attached with super long magnesium stick which protects inner container for a long period of time ensures clarity of water. All-day Operation and Wide Application water heater makes use of sensible heat and hidden heat in the air as low-temperature heat source, so it can continuously supply hot water all day no matter what season or what weather like. It is designed to work at wide ambient temperature range from -15 to 43. Safe and Reliable Multipoint water supply and simultaneous water using Gree air source central water heater can be selected from various models and specifications of main units. Enough water supply capacity and reasonable water system design of central hot water system make water used by a lot of people simultaneously realized. Special high-temperature condition compressor and world-famous parts and components ensure safe and reliable operation of unit. Intelligent water supply and energy saving Timer On, bathing at any time The unit can be started up for water heating in advance according to your habit, giving you more comfortable arrangement. Special thickened inside-thread copper pipe not only enhances heat exchanging performance but also ensures isolation between hot water and refrigerant. Cleaner water makes your life healthier. Intelligent Control Microchip control, easy operation interface, and various kind of history operation data can be tracked. Multi-modular network can control up to 16 host units; parameters of each unit can be freely set. (This is applicable for GRS-Cm18/A-M) Daily timer on/off function; complete safeties to ensure reliable operation. Electric energy drives refrigerant in air source heat pump water heater and refrigerant absorbs heat energy in air to heat water, so the water-electricity isolation is completely realized. Potential fault like electric leakage of using electric water heater, gas poisoning, explosion and dry combustion caused by using gas water heater will never happen on air source heat pump water heater, so it is more safe and reliable than the conventional water heater. 15 16
Parameters AIR SOURCE WATER HEATER R22, 50Hz GRS-C3.5/A1-K GRS-C5.0/A1-K GRS-C7.2/A1-K R410a, 50Hz Rated water heating capacity Rated water supply Water temperature Noise R22 charged volume 3.5 5 7.2 L/h 75 108 155 58 58 58 db(a) 50 52 53 0.65 1 1 220~240V,1Ph, 50Hz 220~240V,1Ph, 50Hz 220~240V,1Ph, 50Hz Power input Water heating 0.9 1.15 1.75 COP(Heating)* Outline dimension (W D H) Package dimension (W D H) s to water tank N.W./G.W. W/W 3.89 4.35 4.11 762 256 750 762 256 750 870 378 882 878 360 800 878 360 800 930 428 994 50/55 55/61 68/79 Rated water heating capacity Rated water supply Water temperature Noise R22 charged volume L/h db(a) Rate power input Water heating COP(Heating)* Outline dimension (W D H) Package dimension (W D H) W/W s Gas(AirCon) Liquid(AirCon) N.W./G.W. GRS-C9/Na-M 9 193 45 60 3.2 380~415V,3Ph,50Hz 2.5 3.6 1018 840 412 1110 880 450 90/100 GRS-C16/Na-M 16 343 45 62 4.5 380~415V,3Ph,50Hz 4.5 3.6 950 1250 340 1110 1280 450 132/145 NOTE:The inner coils water tank must be matched by user. Rated water heating capacity GRS-Cm18/A-M 18 GRS-Cm36/A-M 36 GRS-Cm65/A-M 65 Water Tank Rated water supply L/h 392 780 1400 Water temperature 55 55 55 AIR SOURCE WATER HEATER Noise db(a) 60 65 68 R22 charged volume 4 8.4 17 380V,3Ph,50Hz 380V,3Ph,50Hz 380V,3Ph,50Hz Power input Water heating 4.5 8.7 14.5 COP(Heating)* Outline dimension (W D H) W/W 4 1100 410 1250 4.14 1460 530 1850 4.48 1750 800 1760 With Electric Heater Package dimension (W D H) s to water tank N.W./G.W. 1250 450 1270 1 150/165 1560 710 1960 1 380/400 1860 900 1870 1-450/470 Water tank model Tank volume Auxiliary electrical heater power input SXD150LC-K SXD200LC-K SXD250LC-K SXD300LC-K L 150 200 250 300 1.5 1.5 1.5 1.5 AIR SOURCE WATER HEATER Dimension Outline (Diameter Ht) 520 1350 540 1595 540 1945 620 1620 Package (W D H) 605 610 1375 625 630 1620 625 630 1970 675 680 1720 R134a, 50Hz Rated water heating capacity GRS-C3.8/NbA-K 3.8 GRS-C5.0/NbA-K 5.0 water pipes Cool water inlet Hot water outlet N.W./G.W 45/52 57/66 68/77 71/81 Rated water supply Water temperature Noise R22 charged volume L/h db(a) 82 70 50 0.7 220~240V,1Hp,50Hz 108 70 52 0.95 220~240V,1Hp,50Hz Non Electric Heater Water tank model Tank volume L SX150LC/B1-K 150 SX200LC/B1-K 200 SX250LC/B1-K 250 SX300LC/B1-K 300 SX350LC/B1-K 350 SX400LC/B1-K 400 Power input Water heating COP(Heating)* Outline dimension (W D H) Package dimension (W D H) s to water tank N.W./G.W. W/W 1.02 3.73 762 256 750 878 360 800 50/61 1.35 3.70 762 256 750 878 360 800 50/61 Dimension water pipes Outline (Diameter Ht) Package (W D H) Cool water inlet Hot water outlet N.W./G.W 520x1350 605x610x1375 42/50 540x1595 625x630x1620 55/63 540x1945 625x630x1970 66/75 620x1620 675x680x1720 69/79 620x1895 705x710x1920 77/88 620x2125 705x710x2150 84/96 17 18
NOTE