Fabricated Drainage Products



Similar documents
Storm Drainage Structures

SECTION STORM DRAINAGE SYSTEM

SECTION STORM DRAIN SYSTEM

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION STORM DRAINAGE TABLE OF CONTENTS

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

ROOF DRAINS TABLE OF CONTENTS

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SANITARY SEWER SPECIFICATIONS

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION 7- STORM SEWER

CHAPTER 11 STORM DRAINAGE

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Beacon Hill Sewer District Standard Specifications

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Stormwater/Wetland Pond Construction Inspection Checklist

X Planning X Quality X Maintenance & Operations

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

Table 4.9 Storm Drain Inlet Protetion Applicable for

CLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

Access Hatch Solutions

SECTION INLETS INLET LOCATIONS

Welcome: What is U Drain? Drain Materials. Flow

ADS Water Quality Units

INDEX STORM DRAINAGE PRE-APPROVED NOTES, DESIGN CRITERIA, & PLANS

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

STANDARD SPECIFICATIONS FOR STORM SEWER CONSTRUCTION CITY OF PLYMOUTH, MINNESOTA

Access Hatch Solutions. ejco.com

SECTION POLYVINYL CHLORIDE (PVC) PIPE

LS 2540 SEWER LATERALS AND INSPECTION TEES

DIVISION 4300 STORM DRAINAGE

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

INDEX. Sec. No. Items Page Nos.

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

VDOT 2001 Road and Bridge Standards Section Drainage Items

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Jay R. Smith Mfg. Co.

City of West Linn Public Works Standard Construction Specifications. Table of Contents

The Next Generation in Storm Sewer Inlet Controls

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

CW GRAVITY SEWERS TABLE OF CONTENTS

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

CHAPTER 11 STORM DRAINAGE

FY08 SEWER POINT REPAIRS BID TABULATION

TECHNICAL SPECIFICATION GUIDE

ACO Water Management: Civils + Infrastructure

DRAINAGE MANUAL CHAPTER VII STORM DRAINAGE SYSTEMS

3A General Information A. Concepts... 1 B. Conditions... 1

SECTION UNDERGROUND ELECTRIC SERVICE

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

PLUMBING ROUGH IN INSPECTION

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

SECTION BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.

GRATES AND DRAINS HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

WATER SERVICE 2

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Town House Center Highway North Huntingdon, PA 15642

City of West Linn Public Works Design Standards Table of Contents

SECTION SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS

CLEANING, INSPECTION, AND TESTING OF SEWERS

Storm Drain Inlet Protection

Storm Drain Inlet Protection for Construction Sites (1060)

City of Shelbyville Site Inspection Checklist

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

CHAPTER 6 - SANITARY SEWER

STANDARD SPECIFICATIONS & CONSTRUCTION DETAILS MANUAL SECTION 5 - STORM DRAINAGE Design

FAIRFIELD INDUSTRIES INC.

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

ITD Pipe Materials Selection & Specification Procedures. July 2011

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SECTION GROUND WATER STORAGE TANKS

CHAPTER 5. Storm Sewer

Duraslot Surface Drains

Section 2100-Trenching and Tunneling

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

Drainage Products Catalog. March 2011

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

SECTION DUCTILE IRON PIPE AND FITTINGS

How To Drain A Drainline Grating

Storm Drain Inlet Protection for Construction Sites (1060)

Guidelines for Precast Concrete Grease Interceptors

Royal Seal Gasketed Sewer Pipe

SECTION DUCTILE IRON PIPE AND FITTINGS

Sewage Compliance Form Instructions

SECTION 200: STORM SEWER CONSTRUCTION STANDARDS

Transcription:

Fabricated Drainage Products

Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage Structures are the perfect choice for: Drain Basins are used As a junction box when drainage system inlets / outlets change diameter, change pipe type, change elevation, change direction, and allows for multiple inlets or outlets in one structure For a water inlet and sediment collection point entering a drainage system Commercial Developments Schools and Sports Complexes Roadways and Highways Parking lots Government Installations Parks and Recreation Areas Industrial Parks Golf Courses Residential Developments Economical and Durable Construction HARCO surface drainage structures, including drain basins and inline drains, are manufactured from PVC pipe stock utilizing a thermo-molding process to ensure consistent watertight seal throughout the structure body and the outlet stubs. The raw material used to manufacture this PVC pipe stock shall conform to ASTM D1784 cell class 12454. These heavy-duty PVC structures are abrasion resistant and virtually immune to most types of corrosion. Inlet / Adapters The outlet stubs for HARCO surface drainage structures are manufactured from PVC pipe stock utilizing a thermo-molding process to ensure a tight pipe-to-structure fit that can meet or exceed the pressure requirements of the ASTM D3212 standard for connections joining drainage pipes utilizing flexible elastomeric seals conforming to ASTM F477. To ensure proper fit, simply specify the exact pipe type / brand to connect to the HARCO structure. HARCO surface drainage structures can provide connections to most pipe types / brands including: Most Corrugated Polyethylene Drainage pipe brands PVC Sewer and drainage pipes Iron C900 & C905 Ribbed & Corrugated PVC Made to Order Every drainage system is different. Whether small or large, your drainage system may require adapting to multiple pipe types and diameters, changes in direction and elevation. HARCO Drain Basins are custombuilt in a timely manner for each individual project, ensuring you can meet the design and timeline requirements for your project. HARCO plastic surface drainage structures should be installed following the same ASTM D2321 installation guidelines accepted for backfill, compaction and installation of plastic drainage pipes.

Grates / HARCO Field Tap HARCO grates and covers are designed specifically to fit HARCO surface drainage structures. These castings are manufactured from metal conforming to ASTM A536 grade 80-55-06 for ductile iron. HARCO provides a wide selection of ductile iron castings including: Light duty drop-in grates for nontraffic / turf applications designed primarily to fit 6" 30" corrugated polyethylene pipes Light duty domed / beehive grates available in 6" 30" Round H10 rated grate and frame assemblies for parking lots, pedestrian, and medium duty loads (.5 inch vane spacing conforms to ADA requirements) - fits 12" 30" structures (8" and 10" are 1-piece grates that are light duty only) Round H25 rated grate and frame assemblies for traffic or heavy duty applications - fits 12" 36" structures Round H25 rated solid cover and frame assemblies for maintenance access or heavy duty applications fits 12 36 structures Square hinged H10 and H25 rated grates and frames and Solid covers and frames fit 12" and 15" structures H25 rated 2'x2' square Traffic and Curb Inlet grates, frames, and hood assemblies - fits 12" 30" structures H25 rated 2'x3' rectangular Traffic and Curb Inlet grates, frames, and hood assemblies fits 18" 30" structures Round H-25 Square Hinged H-25 Traffic & Curb H-25 Round H-10 Square Hinged H-10 Curb Diagonal H-25 Round Solid Square Hinged Solid Curb High Flow H-25 HARCO Field Tap The HARCO Field Tap allows you the flexibility to add an inlet or outlet to your HARCO drain basin in-the-field when that unexpected additional line is identified, or if the exact location of that line was not able to be determined prior to basin installation. HARCO Field Taps are available in 4" through 18" diameters. For installation, a drain basin 2 sizes larger than the HARCO Field Tap outlet is required. Examples: 8" HARCO Field Tap requires a 12" basin 12" HARCO Field Tap requires a 18" basin 18" HARCO Field Tap requires a 30" basin Kit Includes: An adhesive-backed cutting template Hole Gasket Bell x spigot adaptor (made to fit pipe you are connecting to) Equipment Needed: Standard drill / bits Jigsaw lubricant

Special Use Drainage Structures Snout Drainage Structure The HARCO Snout-equipped Drainage Structure is a custom drain basin with a plastic composite hood attached to the wall of the drain basin covering the outlet. This simple yet effective cover prevents floating debris, oils, and sediment from exiting the basin where it remains trapped and can easily be removed. The placement of the Snout cover over the basin outlet forces water to exit the basin outlet from the clear zone of water below the floating debris or oils, and creates environment conducive for many contaminants and debris to settle to the bottom of the basin as well. The HARCO Snout Drainage Structure represents a costeffective method for the treating and removal of storm water pollutants. Snouts are factory-installed and available for 18", 24", and 30" diameter HARCO drain basins. Weir Plate Outflow/High- Flow Event Inflow Redirect Flow/ First-Flush Outflow Weir Drainage Structure The HARCO Weir-equipped Drainage Structure is a custom drain basin with a stainless steel weir installed at the factory by HARCO, made to customer specifications. Weir Drainage Structures are perfect for diverting water to preferred outlet within a HARCO drain basin, and also to restrict the flow of water. These weir-equipped HARCO drain basins are widely utilized at the entrance and / or the exit of an underground storm water treatment system or an underground storm water retention / detention system. These custom stainless steel weirs are available for 24, 30, and 36 diameter HARCO drain basins. The customer is responsible for determining weir orientation, weir height, and orifice details for each custom weir drainage structure.

HARCO Drainage Structures Overall Overall Overall Inline Drains 8" 4" 17" 18" 6" 18" 30" 15" 23" 8" 6" 19" 18" 8" 19" 30" 18" 25" 8" 8" 17" 18" 10" 20" 30" 24" 28" 10" 4" 17" 18" 12" 21" 30" 30" 26" 10" 6" 18" 18" 15" 26" 36" 4" 15" 10" 8" 20" 18" 18" 24" 36" 6" 16" 10" 10" 18" 24" 4" 17" 36" 8" 17" 12" 4" 17" 24" 6" 18" 36" 10" 18" 12" 6" 18" 24" 8" 19" 36" 12" 23" 12" 8" 19" 24" 10" 20" 36" 15" 21" 12" 10" 22" 24" 12" 21" 36" 18" 23" 12" 12" 20" 24" 15" 23" 36" 24" 26" 15" 4" 16" 24" 18" 25" 36" 30" 29" 15" 6" 18" 24" 24" 12" 36" 36" 25" 15" 8" 19" 15" 10" 20" 15" 12" 23" 15" 15" 21" 18" 4" 17" 30" 4" 17" 30" 6" 18" 30" 8" 19" 30" 10" 20" 30" 12" 21" *Dimensions within the table are estimated, actual dimensions will vary. Drain Basins Minimum Sump 8" 4 8" 4" 10" 4 10" 6" 12" 4 12" 6" 15" 4 15" 6" 18" 4 18" 6" 24" 4 24" 8" 30" 4 30" 10" 36" 4 30" 14" can be positioned at any angle 0 359 subject to verification

Drain Basin Curb Inlet Structure Curb Inlet Structure Drainage Structure Order Traffic Structure Form Order Form Or Customer Name: Project Name: Project Location: Basin Location: Customer Name: Traffic Structure Customer Name: Project Name: Project Location: Basin Location: Drain Basin Dia.: Grate Type Grate Style Style Grate Type Round One piece (8" and 10" only) H10 Solid Round Round One piece One piece (8" and (8" 10" and only) 10" only) Round Light w/ frame H10 Duty(12" 36" Solid only) Solid Round Round w/ frame w/ frame (12"-36" (12" 36" only) only) One piece H10 Beehive H10 (8" 30" H25 H25 only) H10 Solid Domed H25 Solid Domed/Beehive One piece Beehive (6"-30")(8" 30" only) Square Domed Hinged Domed (12" and 15" only) Square Square Hinged Hinged (12" and (12" 15" and only) 15" only) Traffic H10 (2X2 H10 Square Grate) H25 H25 H10 Solid Standard H25 Diagonal Solid High Flow Locking Grate? yes Locking Gra no Traffic Traffic (2x2 Square (2X2 Square Grate) Grate) Traffic Standard (2X3 Standard Rectangular Grate) Diagonal High Standard Flow Diagonal High Flow D3212 Water Tight Joint Requir Locking Grate? Yes No Traffic Traffic (2x3 Rectangular (2X3 Rectangular Grate) Grate) Curb Inlet Standard (2x2 Standard Square Grate) Diagonal High Standard Flow Diagonal D3212 Water Tight Joint High Flow Required? yes no Curb Inlet Curb (2x2 Inlet Square (2x2 Square Grate) Grate) Curb Inlet Standard (2x3 Standard Rectangular Diagonal Grate) High Standard Flow D3212 Diagonal Water-Tight-Joint High FlowSpecified? Yes No Curb Inlet Curb (2x3 Inlet Rectangular (2x3 Rectangular Grate) Grate) Standard Standard Diagonal Diagonal High Flow Stub #1 Stub #2 Stub #1 Stub #3 Stub #2 Stub #4 Stub #3 Stub #5 Stub #4 Notes: Stub #5 Notes: Grate Type TOP VIEW 315 0 Stub Dia. 270 90 225 180 45 135 Notes: Location (Degrees) Stub #1 Stub #2 Stub #3 Stub #4 Stub #5 TOP VIEW 315 0 Stub Dia. "B" Invert 270 90 225 180 45 135 Customer Approval Min. Rim to Min. Rim to opening height opening height - refer refer to to chart chart for for minimums minimums Customer Approval: Date: Location "B" Invert (Degrees) Type of Drain Basin Project Name: Date: HARCO Quote # Project Location: Basin Location: Drain Basin Dia.: "A" Basin Drain Basin Dia.: Grate Style "A" Basin : Type of Manufacturer Min. Sump "C" and Min. Rim to Opening Min. Sump "C" 8" Basin and 4" 10-18" Basin Min. Rim to 6" Opening Heig 24" Basin 8" Basin 8" 4" 30" Basin 10" 18" Basin10" 6" 36" Basin 24" Basin 14" 8" 30" Basin 10" 36" Basin 14" SIDE VIEW SIDE Min. VIEW Rim to opening height refer to chart for minimums Customer Approval: Date: HARCO Quote # Stub Dia. Location (Degrees) "B" Invert Type of Manufacturer TOP VIEW A - Overall A Overall B - Top of Grate to Invert of B Stub Top of Grate (Flow Line) to Invert of Stub (Flow Line) C - Sump - refer to C Sump refer chart for minimums to chart for minimums *Due to the fact that HARCO Drainage Structures are custom made, they are Non Cancelable and N Distributed by: *Due to the fact that HARCO Drainage Structures are custom made, they are Non Cancelable and Non Returnable HARCO Fittings PO Box 10335 Lynchburg, VA 24506 0335 Phone (800)825 7094 Fax(434) 845 7094 s HARCO Fittings PO Box 10335 Lynchburg, VA 24506 0335 Phone (800)825 7094 Fax(434) 845 7094 sales@harcofittings.com www.harcofittings.com www.harcofittings.com SIDE VIEW HA "A" Basin H Ma THE HARRINGTON CORPORATION P.O. Box 10335 Lynchburg, VA 24506-0335 Phone: (434) 845-7094 Fax: (434) 845-8562 customerservice@harcofittings.com www.harcofittings.com PF161-031815