2 VDOT 2001 Road and Bridge s Page Title EW-1 EW-1A Endwall for Pipe Culverts 12" - 36" Circular and 23" X 14" - 53" X 34" Elliptical Pipes EW-1PC EW-1APC Precast Endwall for Pipe Culverts 12" - 36" Circular and 23" X 14" - 53" X 34" Elliptical Pipes EW-2 EW-2A Endwall for Pipe Culverts 42" - 96" Circular and 60" X 38" - 106" X 68" Elliptical Pipes Endwall for Pipe Culverts 42" - 96" Circular Pipes Endwall for Pipe Culverts 60" X 38" - 106" X 68" Elliptical Pipes EW-2 PC Precast Endwall for 42" - 96" Circular Pipe Culverts EW-2A PC EW-2S Precast Endwall for 60" x 38" - 106" x 68" Elliptical Pipe Culverts Endwalls for 42" - 96" Pipe Culverts 30 and 45 Degree Skews Endwalls for 42" - 96" Pipe Culverts 30 and 45 Degree Skews EW-2S PC Precast Endwalls for Multiple Pipe Culverts EW Endwalls for Multiple Pipe Culverts 12" - 36" Pipe 45 Degree Skew EW-6 PC Precast Endwall for Multiple Pipe Culverts EW-6S EW-6 PC Endwalls for Multiple Pipe Culverts 12" - 36" Pipe 30 Degree Skew Endwalls for Multiple Pipe Culverts 12" - 36" Pipe 45 Degree Skew Precast Endwalls for Multiple Pipe Culverts 12" - 36" Pipe 30 Degree Skew Precast Endwalls for Multiple Pipe Culverts 12" - 36" Pipe 45 Degree Skew EW Endwalls for Multiple Pipe Culverts 42" - 96" Pipe 1 of 10
3 VDOT 2001 Road and Bridge s Page Title EW-7 PC Precast Endwalls for Multiple Pipe Culverts 42" - 96" EW-7S EW-7S PC Endwalls for Multiple Pipe Culverts 42" - 96" Pipe 30 Degree Skew Endwalls for Multiple Pipe Culverts 42" - 96" Pipe 30 Degree Skew Precast Endwalls for Multiple Pipe Culverts 42" - 96" Pipe 45 Degree Skew 7/01 EW Endwalls for Pipe Arches 13" - 38" Rise EW-9 PC Precast Endwalls for Pipe Arches 13" - 38" Rise EW Endwalls for Multiple Pipe Arches 13" - 38" Rise EW-10 PC EW EW-11A EW-11A PC Precast Endwalls for Multiple Pipe Arches 13" - 38" Rise Precast Endwalls with Load-Carrying Grate for 12" - 60" Pipes Pipe Endwalls with Load-Carrying Grate for 12" - 60" Pipes Pipe Endwalls with Load-Carrying Grate for 12" - 60" Pipes Pipe Endwalls with Load-Carrying Grate for 12" -24" Pipes Pipe Endwalls with Load-Carrying Grate for 12" - 24" Pipes Precast Pipe Endwall with Load-Carrying Grate for 12" - 24" Pipe 8/07 A-194 EW Endwalls for Pipe Underdrain 7/04 7/03 A-57 ES ES-1A ES ES Flared End-Section for Concrete Pipe Culverts (12"- 60") Flared End-Section for 23" x 14" to 53" x 34" Elliptical Concrete Pipe Culverts Flared End-Section for 12" - 60" Corrugated Pipe Culverts Flared End-Section for Metal Pipe Arches 13" - 47" Rise 7/01 A-142 7/01 A-130 7/01 A of 10
4 VDOT 2001 Road and Bridge s Page Title Precast Unit Assembly Diagram Legend & General Notes - Precast 7/05 T-DI Precast Top Unit - DI-1 T-DI Precast Top Unit - DI-2 3/03 A-148 T-DI-3, Precast Top Unit - DI-3, DI-4 3/03 A Precast Top Unit - DI-3, DI-4 T-DI Precast Top Unit - DI-5 7/05 T-DI Precast Top Unit - DI-7 7/05 T-MH Precast Manhole Top Units R-1, 2, Precast Reducer and Riser Units B-1, Precast Base Units B Precast Base Unit B Corrugated Metal Base Unit DI DI-1A DI-2A, 2B, 2C Drop Inlet 12"-24" Pipe: Maximum Depth (H) = 10' Drop Inlet 12"-24" Pipe: Depth (H) = 10' to 20' Curb Drop Inlet 12"-24" Pipe: Maximum Depth (H) = 9' 8/07 A-190 8/07 A-190 7/05 1/04 A Dimensions & Quantities 8/07 A-191 DI-2AA, 2BB, 2CC DI-2D, 2E, 2F Curb Drop Inlet 12"-24" Pipe: Depth (H) = 9' to 20' Curb Drop Inlet 30"-48" Pipe: Maximum Depth (H) = 9' 7/05 1/04 A of 10
5 VDOT 2001 Road and Bridge s Page Title DI-2D, 2E, 2F Dimensions & Quantities DI-2DD, 2EE, 2FF DI-3A, 3B, 3C DI-3AA, 3BB, 3CC DI-3D, 3E, 3F DI-3DD, 3EE, 3FF DI-4A, 4B, 4C DI-4AA, 4BB, 4CC DI-4D, 4E, 4F Curb Drop Inlet 30"-48" Pipe: Depth (H) = 9' to 20' Curb Drop Inlet 12"-30" Pipe: Maximum Depth (H) = 8' Dimensions & Quantities Curb Drop Inlet 12"-30" Pipe: Depth (H) = 8' to 20' Curb Drop Inlet (with Utility Space) 12" - 30" Pipe: Maximum Depth (H) = 8' 7/02 7/ Dimensions & Quantities Curb Drop Inlet (with Utility Space) 12" - 30" Pipe: Depth (H) = 8' to 20' Curb Drop Inlet 36"-48" Pipe: Maximum Depth (H) = 8' Dimensions & Quantities Curb Drop Inlet 30"-48" Pipe: Depth (H) = 8' to 20' Curb Drop Inlet (with Utility Space) 36" - 48" Pipe: Maximum Depth (H) = 8' Dimensions & Quantities DI-4DD, 4EE, 4FF Curb Drop Inlet (with Utility Space) 36" - 48" Pipe: Depth (H) = 8' to 16' DI Ditch Drop Inlet 7/ Median Drop Inlet 12" - 42" Pipe DI-7, 7A, 7B Cover & Gutter Details 7/ DI-7, 7A, or 7B with Flume Connection 12" to 36" Pipe DI " Pipe Tee Section Drop Inlet 7/04 A of 10
6 VDOT 2001 Road and Bridge s Page Title DI-10G, 10H, 10I Concrete Median Barrier Drop Inlet Quantities & Dimensions DI-10J, 10K, 10L Concrete Median Barrier Drop Inlet Concrete Median Barrier Drop Inlet 7/02 7/01 A Multigrate Drop Inlet for Pipe Sizes 12" - 72" DI-12, 12A Grate Details 8/07 2/06 7/05 A Quantities & Dimensions DI-12B, 12C DI Multigrate Drop Inlet for Pipe Sizes 12" - 36" 8/07 2/06 7/05 A Grate Details & Quantities 8/07 2/06 7/05 A Shoulder Slot Inlet 8/07 A Shoulder Slot Inlet 8/07 7/05 A-165 PI Method of Outlet Pipe Installation for DI-13 DI-14A, 14B, 14C DI-14A, 14B, 14C DI-14D, 14E, 14F Concrete Median Barrier Drop Inlet (Tall Wall) 2/06 A Quantities & Dimensions 2/06 A Concrete Median Barrier Drop Inlet (Tall Wall) 7/01 A Concrete Median Barrier Drop Inlet (Tall Wall) 7/01 A-102 DI-MB Concrete Masonry Block Curb Drop Inlet IC Inlet Frame and Cover 8/07 A-192_ Inlet Frame and Cover 8/07 A-192_1 5 of 10
7 Page Title VDOT 2001 Road and Bridge s IC Precast Inlet and Frame Cover 8/07 A-192_ Manhole for 12" to 48" Pipe Culvert 7/ Manhole Frame and Cover MH Manhole Frame and Cover Manhole Frame and Cover 7/02 A Manhole Frame and Cover MH-1A Manhole Frame and Cover MH Precast Manhole IS Method for Shaping Manhole and Inlet Culverts ST Step JB SL Junction Box Chamber Details for 48" - 72" Pipe Culverts Junction Box Details for Angular Connections of 48" - 72" Pipe Culverts Junction Box Tower Details for 48" - 72" Pipe Culverts Junction Box Displacement Quantities for 48" - 72" Pipe Culverts Typical Concrete Safety Slab for Drop Inlets, Manholes & Junction Boxes 7/05 A-62 DSB Drainage Structure Bedding 9/06 A-186 PB PB Installation of Pipe Culverts and Storm Sewers Circular Pipe Bedding and Backfill - Notes Installation of Pipe Culverts and Storm Sewers Circular Pipe Bedding and Backfill - Method "A" 1/04 A-151 8/07 7/05 1/04 A-86 6 of 10
8 VDOT 2001 Road and Bridge s Page Title PB Installation of Pipe Culverts and Storm Sewers Elliptical Pipe Bedding and Backfill - Method "A" Installation of Pipe Culverts and Storm Sewers Pipe Arch Bedding and Backfill Installation of Pipe Culvert Bedding and Backfill Method "A" 8/07 7/05 7/04 1/04 A-86 8/07 7/05 1/04 A-120 1/04 A Concrete Pipe - Class Table for H-20 Live Load 7/05 7/01 A Elliptical Concrete Pipe - Table for H-20 Live Load 7/05 A PC Corrugated Steel Pipe - Height of Cover Table for H- 20 Live Loading Corrugated Aluminum Alloy Pipe - Height of Cover Table for H-20 Live Load Corrugated Aluminum Alloy Pipe - Height of Cover Table for H-20 Live Load Corrugated Steel Pipe Arch - Height of Cover Table for H-20 Live Load Corrugated Aluminum Alloy Pipe Arch - Height of Cover Table for H-20 Live Load Structural Plate Steel Pipe - Height of Cover Table for H-20 Live Load Structural Plate Aluminum Alloy Pipe - Height of Cover Table for H-20 Live Load Structural Plate Steel Pipe Arch - Height of Cover Table for H-20 Live Load Structural Plate Steel Pipe Arch - Height of Cover Table for H-20 Live Load Structural Plate Aluminum Alloy Pipe Arch - Height of Cover Table for H-20 Live Load Aluminum Spiral Rib Pipe - Height of Cover Table for H-20 Live Load Steel Spiral Rib Pipe - Height of Cover Table for H- 20 Live Load 7/05 A /05 A /05 A /05 A /05 A /05 A /05 A /05 A /05 A /05 A /05 A /05 A Cast Iron Pipe - Strength Table for H-20 Live Load 7/05 A of 10
9 VDOT 2001 Road and Bridge s Page Title PC-1 Vitrified Clay and Plastic Pipe - Maximum Cover Table for H-20 Load A AllowablePipeCriteriaforCulvertsandStorm Sewers AllowablePipeCriteriaforCulvertsandStorm Sewers 9/06 7/05 7/01 A /06 7/05 2/08 7/05 9/06 PP Details for Backfilling Abandoned Culverts UD Groundwater Underdrain 8/07 2/06 7/03 A-80 UD Pipe Underdrain for use with Raised Grass Median Strips 8/07 2/06 7/03 A-80 UD Sidewalk Underdrain 8/07 2/06 7/03 A-55 CD CD Combination Underdrains (at lower end of cuts) Combination Underdrains (at grade sags and bridge approaches) 8/07 7/03 A-84 8/07 7/03 A-84 UD Pavement Edgedrain 8/07 1/04 7/03 A Pavement Edgedrain 8/07 2/06 7/03 A-81 UD Prefabricated Geocomposite Retrofit Pavement Edgedrain 8/07 A-82 UD Retrofit Edgedrain 8/07 2/06 7/03 A-83 PG-2A Paved Ditches 7/04 7/02 ISD-570 PG a Rip Rap Ditch and Slope Protection 7/03 ISD-570 PG Paved Flume for 12" - 24" Pipe Culverts PG Paved Ditches PG-6A, 6B Precast Paved Ditches PG Ditch Flume Connector 7/02 ISD-564A 8of10
10 Page Title VDOT 2001 Road and Bridge s SB Spring Box 3/03 7/01 A-143 SB-1 PC Precast Spring Box 3/03 7/01 A-143 EG-1, 1A Energy Dissipator for use with Paved Flume EG-1, 1A PC Precast Energy Dissipator PS Pipe Spillout for 12" - 18" Pipe Culverts PS Pipe Spillout for 21" - 30" Pipe Culverts TD-CL Temporary Diversion Channel & Acceptance Linings EC Stone for Erosion Control 8/07 9/06 A-69 EC Protective Covering Installation Criteria Soil Stabilization Criteria 8/07 7/05 A-70-1 EC A Soil Stabilization Mat Culvert Outlet Protection Installation 8/07 A Soil Stabilization Mat Slope Installation 8/07 A-70-2 EC Rock Check Dam Type I & II EC Temporary Silt Fence and Filter Barrier 9/06 3/03 ISD EC Drop Inlet Silt Trap (Type A and B) 3/03 7/01 ISD EC Typical Sediment Trap EC Dewatering Basin EC Temporary Diversion Dike 9 of 10
11 Page Title ESC-INS VDOT 2001 Road and Bridge s Temporary Erosion & Siltation Control 7/04 1/04 3/03 ISD Temporary Erosion & Siltation Control ESC-INS Temporary Erosion & Siltation Control SWM Cast-In-Place Stormwater Management Drainage Structure Precast Stormwater Management Drainage Structure Stormwater Management Drainage Structure (SWM) Details 3/03 ISD /03 ISD-2216 VOID 3/ Stormwater Management (SWM) Details 3/03 ISD-2216A Stormwater Management (SWM) Details 3/03 ISD-2209 SWM-DR Stormwater Management (SWM) Details 3/03 ISD Stormwater Management (SWM) Details 3/03 ISD-2216A Stormwater Management (SWM) Details 3/03 ISD-2216A 10 of 10
SECTION III DRAINAGE
SECTION III DRAINAGE TOC-III.1 of 5 TABLE OF CONTENTS DRAINAGE FACILITIES No. Title D-1 Standard Underdrains D-2 Longitudinal Underdrain for Flexible Paving D-3 Spring Control Method & Detail D-4 Trench
More informationSECTION 02530 STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02530-1 of 5 SECTION 02530 STORM DRAINAGE STRUCTURES 02530.01 GENERAL A. Description Storm drainage structure construction shall include, but not necessarily be limited to, furnishing and installing or
More informationSECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
More informationA. Structures Quantity Item Price Cost @ $3,500 EA
PRINCE WILLIAM COUNTY Department of Development Services Land Development Division UNIT PRICE LIST (Performance Bonds, Landscaping Escrows, and Siltation & Erosion Control Escrows) Revised: November 17,
More informationSection 600 Incidental Construction
Table of Contents 1. Pipe Culverts... 600-1 A. Endwalls, Inlets, Manholes, and Spring Boxes... 600-5 2. Grade Adjustment of Existing Miscellaneous Structures... 600-8 3. Rebuilt Miscellaneous Structures...
More informationCity of Shelbyville Site Inspection Checklist
City of Shelbyville Site Inspection Checklist General Information Project Name: KYR10 Permit Number: Date: Project Location: Contractor: Conractor Representative: Inspector's Name: Title: Signature : Weather
More informationPUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Storm Sewer Design Criteria REVISED July 2009 PUBLIC WORKS STORM SEWER DESIGN CRITERIA TABLE OF CONTENTS 1.0
More informationCHAPTER 17: STORM SEWER STANDARDS. 17.00 Introduction. 17.01 Administration. 17.02 Standards 17.1
CHAPTER 17: STORM SEWER STANDARDS 17.00 Introduction 17.01 Administration 17.02 Standards 17.1 17.00 INTRODUCTION The purpose of this chapter is to provide guidance for the design and construction of storm
More informationSECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
More informationStormwater/Wetland Pond Construction Inspection Checklist
: Construction Inspection ChecklistsTools Stormwater/Wetland Pond Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: SATISFACTORY/ UNSATISFACTORY COMMENTS Pre-Construction/Materials
More informationSTORM DRAINS CHAPTER 7
CHAPTER 7 Chapter 7 - Storm Drains A storm drain is a drainage system that conveys water or stormwater, consisting of two or more pipes in a series connected by one or more structures. Storm drains collect
More informationCHAPTER 5. Storm Sewer
CHAPTER 5 Storm Sewer A. Introduction All proposed developments shall have a properly designed and constructed storm water conveyance system. This chapter deals only with the conveyance system. Storm water
More informationOutlet stabilization structure
Overview of Sedimentation and Erosion Control Practices Practice no. 6.41 Outlet stabilization structure Erosion at the outlet of channels, culverts, and other structures is common, and can cause structural
More informationLINDEN PARK PH. 11 PROJECT NO. 53B22353 SHEET NO. D-5 DETAIL TYPICAL SECTION CITY OF MADISON SIDEWALK COMPLETION DETAILS ROW VAR. 9"-12" ORIGINATOR: CITY OF MADISON, STREETS DIVISION REV. DATE: PLOT NAME:
More informationvolume of concrete occupied by the drain pipe in a cast-in-place structure or structure extension.
715.01 430 volume of concrete occupied by the drain pipe in a cast-in-place structure or structure extension. No additional payment will be made for the repair or replacement of existing concrete damaged
More informationSection 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
More informationUnit Price Averages Reports
Unit Price Averages Reports 12/7/2015 UNIT PRICE AVERAGES REPORT Disclaimer The information provided in the following Unit Price Averages Report is only for the use of Alberta Infrastructure & Transportation
More informationSECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
More informationChapter 9 - Storm Drains
Chapter 9 - Storm Drains TABLE OF CONTENTS CHAPTER 9 - STORM DRAINS... 9-1 9.1 Introduction... 9-1 9.1.1 Objective 9-1 9.2 Design Policy... 9-2 9.2.1 Definition 9-2 9.2.2 General Policies... 9-2 9.3 Design
More informationDIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
More informationSECTION 108 - INLETS 108.1 INLET LOCATIONS
Greene County Design Standards -Adopted April 5, 1999 SECTION 108 - INLETS SECTION 108 - INLETS 108.1 INLET LOCATIONS 108.2 INLET INTERCEPTION CAPACITIES 108.2.1 Clogging Factors 108.3 INTERCEPTION AND
More informationCITY OF VISTA STANDARD DRAWINGS (PRELIMINARY, FOR REVIEW)
CITY OF VISTA STANDARD DRAWINGS (PRELIMINARY, FOR REVIEW) January, 2013 THIS SHEET INTENTIONALLY LEFT BLANK TABLE OF CONTENTS DRAINAGE STRUCTURES DRN-01 Corrugated metal pipe drop inlet DNR-02 Storm Drain
More informationFabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
More informationSTANDARD SPECIFICATIONS & CONSTRUCTION DETAILS MANUAL SECTION 5 - STORM DRAINAGE. 5.01 Design
SECTION 5 - STORM DRAINAGE 5.01 Design Storm drainage facilities shall be designed in accordance with the goals and guidelines set forth in the Unified Development Ordinance. The goal shall be to collect
More informationFDOT DBE CERTIFICATION NAICS CODE GUIDE WITH CAP SIZES
NAICS CODE Highway, Street, and Bridge Construction SIZE CAP ($ MIL) 237310 Asphalt Roadway (includes 300, 320, 327, 330, 334, 336, 337, 338) Application of prime and tack coats, leveling surfaces and
More informationBMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.
BMP-7 BMP: STORM DRAIN INLET PROTECTION Definition A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet. To prevent sediment from entering storm drainage systems
More informationTable 4.9 Storm Drain Inlet Protetion Applicable for
BMP C220: Storm Drain Inlet Protection Purpose To prevent coarse sediment from entering drainage systems prior to permanent stabilization of the disturbed area. Conditions of Use Type of Inlet Protection
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationSECTION 724 PIPE CULVERTS
SECTION 724 PIPE CULVERTS 724.1 Description. This work shall consist of providing pipe or pipe arch of the diameter or shape designated, laid upon a firm bed and backfilled as specified. Where appropriate
More informationTable of Contents. 2015 Con Cast Pipe Price List - Page 1
Table of Contents Conditions of Sale - Pages 2 & 3 Reinforced Concrete Pipe, Caps, and Plugs - Page 4 Scribed Holes & Knockouts - Page 4 Reducers & Increasers - Page 4 Concrete Pipe Approximate Mass &
More informationSEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST
SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST For permanent structures per Delaware SCS Pond Code 378 and Delaware Sediment and Stormwater Regulations KEY PROJECT INFORMATION Item meets standard
More informationState of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
More informationFY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation
644-10-569 Page 1 of 9 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING
More informationIndex. protection. excavated drop inlet protection (Temporary) 6.50.1 6.51.1. Block and gravel inlet Protection (Temporary) 6.52.1
6 Index inlet protection excavated drop inlet protection (Temporary) 6.50.1 HARDWARE CLOTH AND GRAVEL INLET PROTECTION Block and gravel inlet Protection (Temporary) sod drop inlet protection ROCK DOUGHNUT
More informationFY08 SEWER POINT REPAIRS BID TABULATION
6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "
More informationSECTION 6A STORM DRAIN DESIGN Mar. 2002 S E C T I O N 6A STORM DRAIN - DESIGN
S E C T I O N 6A STORM DRAIN - DESIGN 6A.l Scope 6A.2 Storm Water Quantity 6A.3 Storm Drain Hydraulics 6A.4 Depths 6A.5 Locations 6A.6 Curved Storm Drains 6A.7 Manholes 6A.8 Catch basins 6A.9 Storm Drain
More informationHow To Build A Road In A Townhouse
FDOT DBE CERTIFICATION SPECIALTY/ SHEET WITH CAP SIZES Highway, Street, and Bridge Construction SIZE CAP ($ MIL) 237310 Asphalt Roadway $ 22.41 Application of prime and tack coats, leveling surfaces and
More informationVILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER ST-09-06 BID PROPOSAL
VILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER ST-09-06 BID PROPOSAL I/We hereby agree to furnish to the Village of Lombard all necessary materials, equipment, and labor, to complete the North Industrial
More informationSTANDARD INSPECTION FORM GENERAL PERMIT FOR STORMWATER ASSOCIATED WITH CONSTRUCTION ACTIVITY
STANDARD INSPECTION FORM GENERAL PERMIT FOR STORMWATER ASSOCIATED WITH CONSTRUCTION ACTIVITY Project Name Permittee NOI # Start Time Inspector s Name(s) Green Card Certification # Inspector s Contact Information
More informationSTANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION
STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION Design Criteria Drainage Area The drainage area for storm drain inlets shall not exceed one acre. The crest elevations of these practices shall
More informationFDOT Specifications List
FDOT Specifications List TABLE OF CONTENTS DIVISION II CONSTRUCTION DETAILS CLEARING CONSTRUCTION SITE 110 Clearing and Grubbing... 152 EARTHWORK AND RELATED OPERATIONS 120 Excavation and Embankment...
More informationStorm Drain Inlet Protection
Categories EC Erosion Control SE Sediment Control TC Tracking Control WE Wind Erosion Control Non-Stormwater NS Management Control Waste Management and WM Materials Pollution Control Legend: Primary Category
More informationConstruction Site Inspection Checklist for OHC000004 By making use of some simple Best Management Practices (BMPs) a construction site operator can
Construction Site Inspection Checklist for OHC000004 By making use of some simple Best Management Practices (BMPs) a construction site operator can do his or her share to protect Ohio's water resources
More informationDRAINAGE MANUAL CHAPTER VII STORM DRAINAGE SYSTEMS
TDOT DESIGN DIVISION DRAINAGE MANUAL CHAPTER VII STORM DRAINAGE SYSTEMS August 1, 2012 CHAPTER 7 STORM DRAINAGE SYSTEMS SECTION 7.01 INTRODUCTION 7.01 INTRODUCTION...7-1 SECTION 7.02 DOCUMENTATION PROCEDURES
More informationLand Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department
Land Disturbance, Erosion Control and Stormwater Management Checklist Walworth County Land Conservation Department The following checklist is designed to assist the applicant in complying with the Walworth
More informationJune 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
More informationSECTION 7- STORM SEWER
SECTION 7- STORM SEWER 7.1. STORM SEWERS.... 7-1 7.2. SUMP DRAINS... 7-3 7.3. CATCH BASINS... 7-3 7.4. MANHOLES... 7-4 7.5. STORM SEWER CALCULATIONS... 7-4 7.6. CULVERTS AND BRIDGES... 7-5 7.7. OPEN CHANNELS...
More informationStorm Drain Inlet Protection - IP
Storm Drain Inlet Protection - IP DEFINITION A temporary protective device formed around a storm drain drop inlet to trap sediment. PURPOSE To prevent sediment from entering storm drainage systems, prior
More informationSITE-SPECIFIC BEST MANAGEMENT PRACTICES (SSBMP) PLAN/STORM WATER POLLUTION PREVENTION PLAN (SWPPP) REVIEW CHECKLIST
This checklist may be used by applicants for encroachment permits, and contractors in development of Site Specific Best Management Practice (SSBMP) Plans or Storm Water Pollution Prevention Plans (SWPPP)
More informationChapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile
Chapter 3 CULVERTS Description A culvert is a closed conduit used to convey water from one area to another, usually from one side of a road to the other side. Importance to Maintenance & Water Quality
More informationINDEX STORM DRAINAGE PRE-APPROVED NOTES, DESIGN CRITERIA, & PLANS
INDEX STORM DRAINAGE POLICIES D-1 NOT USED D-2 Small Project Drainage Review Requirements D-3 Targeted and Full Drainage Review Requirements D-4 Prohibited and Allowed Discharges to the Storm Drainage
More informationNebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY
Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY Policy: This policy will replace all previous policies regarding the selection of pipe material for cross drains, drive pipe, drop pipe, storm
More informationSITE-SPECIFIC BEST MANAGEMENT PRACTICES (BMP) PLAN REVIEW CHECKLIST
This checklist may be used by applicants for encroachment permits, and contractors in development of Site- Specific BMP Plans for projects. plan reviewers will use this checklist to review the Site-Specific
More information550 PIPE CULVERTS, SEWERS AND DRAINS
551.01 550 PIPE CULVERTS, SEWERS AND DRAINS 551 GENERAL 551.01 Description 551.02 Materials 551.03 Excavation 551.04 Protection of Excavation 551.05(a) Bedding for Rigid Pipe 551.05(b) Bedding for Non-Rigid
More informationPLAN VIEW FOR LAKE OR MARSH FRONT VIEW FOR FLOTATION SILT CURTAIN
OF WATERWAY PERIMETER CONTROL LESS THAN / THE STREAM/RIVER STEEL FENCE POST ANCHOR TO LAND (TYP.) / DEPTH OF WATER PLOTTED/REVISED:-OCT-0 WIDTH STREAM BANK TEMPORARY ROCK BERM BRIDGE ABUTMENT, CULVERT
More informationUNIT PRICE LIST January 2009
UNIT PRICE LIST January 2009 1 INTRODUCTION The purpose of the Unit Price List is to provide a resource for the preparation of cost estimates for subdivisions and permit projects and should be used only
More informationTown of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control
Town of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control Project Name: Tax Map Parcel: Acreage: Plat: ADC Map & Grid Engineering
More informationAPPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.
Storm Drainage 13-C-1 APPENDIX C INLETS 1.0 Introduction The application and types of storm drainage inlets are presented in detail in this Appendix. 2.0 Inlet Locations Inlets are required at locations
More informationCast iron swing grate in cast iron frame. 300x300 ID concrete chamber. Available chamber depths 400mm or 600mm deep. K&C Roadway SITE PLAN
Cast iron swing grate in cast iron frame Nominal 90 mm inlet SECTION x ID concrete chamber. vailable chamber depths 400mm or 600mm deep CHMBER PLN Stormwater pipe House Chamber location in vehicle cutdown
More informationSection 402. STORM SEWERS
402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide
More informationDrainage DR-701. Materials Field Sampling. Purpose of the Guidance Manual. General DR 701-1
DR-701 Chapter Materials Field Sampling Drainage Subject INLETS INTRODUCTION & STORM SEWERS General Purpose of the Guidance Manual DR 701-1 STORM SEWER DEFINITION KYTC defines a storm sewer as two or more
More informationEngineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18
Schedule H to Bylaw 7452, Subdivision Bylaw Page 18 3.4 Sanitary Sewers 3.4.1 Materials 3.4.1.1 The class and type of pipe and fittings, together with required class of bedding and trench widths, shall
More informationSE-10 STORM DRAIN INLET PROTECTION. Objectives
STORM DRAIN INLET PROTECTION SE-10 Objectives Erosion Control - EC Sediment Control - SE Tracking Control - TC Wind Erosion Control - WE Non-Storm Water Management - NS Waste and Materials Management -
More informationSTORM DRAIN STRUCTURES (G 600)
TABLE OF CONTENTS STORM DRAIN STRUCTURES (G 600) SECTION NO. SUBJECT DATE G 601 Design Responsibility G 602 Structural Criteria " G 610 CONDUITS " G 611 Applications " G 612 Configurations " G 613 Loading
More informationDESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS
DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS Phase I MS4 permits require continuous updating of the stormwater system inventory owned and operated by the MS4. They also include inspection
More informationSTORM WATER PROJECT COST ESTIMATES & LOCATION MAPS. Appendix F
STORM WATER PROJECT COST ESTIMATES & LOCATION MAPS Appendix F RIVERDALE CITY CAPITAL FACILITIES PLAN STORM DRAINAGE Engineer's Cost Estimate January 2009 Project Name: 4400 South Street - Piping and Collection
More informationCONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN TEMPLATE
CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN TEMPLATE The following template may be used as a general guide for development of a Stormwater Pollution Prevention Plan (SWPPP) for construction activities.
More informationPermeable Pavement Construction Guide
Permeable Pavement Construction Guide Permeable pavement at Olympic Park, Waitakere Final Construction result What are permeable pavements? Permeable pavements are hard surface paving systems that reduce
More informationDESIGN COEFFICIENT TABLES
DESIGN COEFFICIENT TABLES Hazen-Williams Friction Factor (C) Pipe Material Values for C Range Average Value Typical Design Value High/Low Plastic, PVC, Polyethylene 160/150 150-155 150 pipe or tubing Cement
More informationCity of West Linn Public Works Standard Construction Specifications. Table of Contents
City of West Linn Public Works Standard Construction Specifications Table of Contents DIVISION SIX STORM DRAIN TECHNICAL REQUIREMENTS... 1 601 PIPE AND FITTINGS... 1 601.01 Description...1 601.02 Materials...1
More informationVDOT 2001 Road and Bridge Standards Section 500 - Guardrail, Fences, and Markers
VDOT 2001 Road and Bridge s Page Title 501.01 Guardrail Hardware GR-HDW 501.02 Guardrail Hardware 501.03 Guardrail Hardware GR-2, 2A 501.04 501.05 Blocked-Out W Beam Guardrail (Strong Post) Blocked-Out
More informationStorm Drain Inlet Protection
Objectives EC Erosion Control SE Sediment Control TR Tracking Control WE Wind Erosion Control Non-Stormwater NS Management Control Waste Management and WM Materials Pollution Control Legend: Primary Objective
More informationCD i -STREETS- Detail #
-STREETS- Detail # 3000 Vertical Curb, Gutter and Sidewalk 3010 Low-Profile Curb, Gutter and Sidewalk 3020 Rolled Curb, Gutter and Sidewalk 3030 Separated Sidewalk, Curb & Gutter 3040 Sidewalk Staged Construction
More informationChapter 9 Storm Sewers
Contents 1.0 Introduction... 1 2.0 Design Storms... 1 2.1 Minor Event... 1 2.2 Major Event... 1 3.0 Pipe Material and Size... 2 3.1 Pipe Material... 2 3.2 Minimum Pipe Size... 2 3.3 Service Life... 2 3.4
More informationCHAPTER 7 DRAINAGE OF PAVEMENTS
CHAPTER 7 DRAINAGE OF PAVEMENTS 7-1. Drainage control Adequate drainage of surface and ground water is one of the most important considerations in the design, construction, and maintenance of roads, railroads,
More informationSTANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF MANITOWOC, WISCONSIN SECTION 400 SEWER AND WATER CONSTRUCTION
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF MANITOWOC, WISCONSIN SECTION 400 SEWER AND WATER CONSTRUCTION Section Number Title 401 GENERAL 402 AMENDMENTS TO WSWS PART I - GENERAL CONDITIONS
More informationSECTION 200: STORM SEWER CONSTRUCTION STANDARDS
SECTION 200: STORM SEWER CONSTRUCTION STANDARDS Page No. Description 200-2 201 GENERAL 200-2 201.1 SPECIFICATIONS 200-2 201.2 CONNECTION TO EXISTING FACILITIES 200-3 202 MATERIALS 200-3 202.1 PIPES 200-4
More informationLos Angeles County Department Of Public Works. Land Development Division. Bond Calculation Sheets
Los Angeles County Department Of Public Works Land Development Division Bond Calculation Sheets Effective July 1, 2015 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS LAND DEVELOPMENT DIVISION ROADS COST
More informationDESCRIPTION OF WORK:
DEPARTMENT OF PUBLIC WORKS COUNTY OF HENRICO P.O. BOX 27032 RICHMOND, VIRGINIA 23273 PERMIT NO. One (1) copy of application and four (4) copies of plans are hereby made to the Director of Public Works
More informationCulvert Repair, Materials, and Structural Design 4.4-1
Culvert Repair, Materials, and Structural Design 4.4-1 4.4 Culvert Materials 4.4.1 General Culverts are primarily made with reinforced concrete, corrugated metal, and more recently, solidwall, profile
More informationBUSINESS DEVELOPMENT INITIATIVE SMALL BUSINESS PROGRAM GUIDANCE FOR RESERVING CONTRACTS
Construction/Maintenance Contracts and Design/Build Low Bid Contracts 1. Districts are responsible for reviewing their work program and identifying contracts that are good candidates for the Business Development
More informationA perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.
BMP: SUBSURFACE DRAIN Definition A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. PurRoses 1. To prevent sloping soils from becoming
More informationX Planning X Quality X Maintenance & Operations
Delaware Department of Transportation Division of Transportation Solutions Design Guidance Memorandum Memorandum Number 1-20 Revised 1. Road Design Manual 2. Bridge Design Manual 3. Utilities Design Manual
More informationSECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
More informationDemo Existing Curb Demo Existing Asphalt Roadway Demo Asphalt Saw Cutting Protection Fence - 4 Snow Fence with T posts
SECTION 00300 BID FORM S For additions and deletions to the Contract, the following unit prices shall be applicable for the specific items listed. Unit Prices shall be complete, in place including required
More informationMONETARY GUARANTY PROCEDURE PACKAGE FREDERICK COUNTY, VIRGINIA
MONETARY GUARANTY PROCEDURE PACKAGE FREDERICK COUNTY, VIRGINIA Department of Planning and Development 107 North Kent Street, Suite 202 Winchester, Virginia 22601 Phone: (540) 665-5651 Fax: (540) 665-6395
More informationSECTION 701 CULVERT PIPE, ENTRANCE PIPE, STORM SEWER PIPE, AND EQUIVALENTS
SECTION 701 CULVERT PIPE, ENTRANCE PIPE, STORM SEWER PIPE, AND EQUIVALENTS 701.01 DESCRIPTION. Furnish and install culvert pipe, entrance pipe, and storm sewer pipe. Use units conforming to the dimensions,
More informationIntroduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
More information8-11 Structural Analysis and Fill Height Tables... 42 8-11.1 Pipe Cover... 43 8-11.2 Shallow Cover Installation... 43 8-11.3 Fill Height Tables...
Contents Chapter 8 Pipe Classifications and Materials...1 8-1 Classifications of Pipe... 1 8-1.1 Drain Pipe... 2 8-1.2 Underdrain Pipe... 2 8-1.3 Culvert Pipe... 3 8-1.4 Storm Sewer Pipe... 7 8-1.5 Sanitary
More informationLS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
More informationBUSINESS DEVELOPMENT INITIATIVE SMALL BUSINESS PROGRAM GUIDANCE FOR RESERVING CONTRACTS
Construction/Maintenance Contracts and Design/Build Low Bid Contracts 1. Districts are responsible for reviewing their work program and identifying contracts that are good candidates for the Business Development
More informationSafe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
More informationStorm Drain Inlet Protection
Source: Caltrans Construction Site Best Management Practices Manual, 2003. Description Applications Installation and Implementation Requirements Devices installed at storm drain inlets to detain and/or
More informationCASFM Stormwater Quality Field Trip June 23rd, 2011
CASFM Stormwater Quality Field Trip June 23rd, 2011 The 2011 CASFM Stormwater field trip included 42 attendees coming from as far south as Colorado Springs up to the Denver area and another 12 who joined
More information2011 HYDRAULICS MANUAL
STATE OF LOUISIANA DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT P.O. Box 94245 Baton Rouge, Louisiana 70804-9245 http://www.dotd.la.gov/ HYDRAULICS MANUAL Hydraulics (225) 379-1306 PREFACE The following
More informationSAMPLE COPY. Stormwater Pollution Prevention Plan. A site map must be developed and must contain, at a minimum, the following information:
Stormwater Pollution Prevention Plan "I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure
More informationSUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
More informationSECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS
SECTION 02700 SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the General and Supplementary Conditions and Division 1 Specification
More informationMinimizes sediment and debris from entering storm drains that lead to waterways and watercourses.
4.5-p DRAIN INLET PROTECTION Alternative Names: DI protection, Drop Inlet Protection DESCRIPTION Storm drain inlet (DI) protection slows and ponds stormwater, and filters sediment and debris before it
More informationStorm Drain Inlet Protection for Construction Sites (1060)
Storm Drain Inlet Protection for Construction Sites (1060) Wisconsin Department of Natural Resources Conservation Practice Standard I. Definition A temporary device installed in or around a storm drain
More information