Report to the CCRI Section II on the activity carried out at the ENEA-INMRI on radionuclide measurements in the period 2003-2005



Similar documents
RESULTS OBTAINED IN MEASUREMENTS OF Rn-222 WITH THE ROMANIAN STANDARD SYSTEM*

Ionizing Radiation, Czech Republic, CMI (Czech Metrology Institute)

A methodological approach for sediment core dating

Perspectives of a method for measuring soil-gas radon by an opened counting vial

Individual Monitoring Services (IMS) for External and Internal Exposures

Application Note. Monitoring the Release of Radioactive Noble Gases Through the Stack of a Nuclear Power Plant (NPP): Stack Monitor System

CURRICULUM VITAE DI FEDERICO LUCHI

Syringe Calibration Factors and Volume Correction Factors for the NPL Secondary Standard Radionuclide Calibrator.

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

A Review of Emerging Gamma Detector Technologies for Airborne. Radiation Monitoring

Efficiency calibration of the Ge(Li) detector of the BIPM for SIR-type ampoules

Dipartimento di ENERGIA

Laue lens for Nuclear Medicine

GIBITRE INSTRUMENTS S.R.L. VIA MEUCCI CURNO BG ITALY INTERNAL TENSOR CHECK. GIBITRE Instruments TENSOR CHECK COMPACT-PC

INFO-0545 RADIOISOTOPE SAFETY MONITORING FOR RADIOACTIVE CONTAMINATION

The Radon Calibration Laboratory at the Federal Office for Radiation Protection (BfS)

USCEA/NIST MEASUREMENT ASSURANCE PROGRAMS FOR THE RADIOPHARMACEUTICAL AND NUCLEAR POWER INDUSTRIES

Antoine Henri Becquerel was born in Paris on December 15, 1852

Radiation Monitoring System DLMon

Tutorial 4.6 Gamma Spectrum Analysis

Radiological mapping and characterization at the Barsebäck nuclear power plant

COMPENDIUM OF EPA-APPROVED ANALYTICAL METHODS FOR MEASURING RADIONUCLIDES IN DRINKING WATER

REPORT TO THE CCRI SECTION I ON THE ACTIVITY CARRIED OUT AT ENEA- INMRI ON PHOTON AND CHARGED PARTICLE DOSIMETRY IN THE PERIOD

Qualitätsmanagement-Handbuch

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza

Lecce (Italy) 17th JUNE, 2016 HILTON GARDEN INN

United States Office of Radiation and October 1998 Environmental Protection Indoor Air Agency. Radiation and Indoor Environments National Laboratory

Eckert & Ziegler Reference & Calibration Sources

Giordano Cattani Curriculum Vitae

Radium-223 Therapy: Handling & Radiation Safety Issues

DETERMINATION OF THE EFFECTIVE VOLUME OF AN EXTRAPOLATION CHAMBER FOR X-RAY DOSIMETRY

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

COLLEGE ON MEDICAL PHYSICS

CRIIRAD report N Analyses of atmospheric radon 222 / canisters exposed by Greenpeace in Niger (Arlit/Akokan sector)

Proficiency testing schemes on determination of radioactivity in food and environmental samples organized by the NAEA, Poland

Digital performance of Italy

Radiation Detection and Measurement

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Radionuclide and Noble Gas Data Processing and Analysis

ISTITUTO NAZIONALE DI FISICA NUCLEARE CONSIGLIO DIRETTIVO DELIBERAZIONE N

WM2012 Conference, February 26 -March 1, 2012, Phoenix, Arizona, USA

CURRICULUM VITAE. Mobile WORK EXPERIENCE. Date June 2011 Name and address of employer

Round Table Italy-Russia at Dubna

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Dinamica dell Electron Cloud: Calcolo dei Coefficienti della Mappa

P O L Y T E C R.M. S.R.L.

POTENTIAL IMPACT ON THE REDUCTION OF GREENHOUSE GAS EMISSIONS RESULTS OF INTERVENTIONS FINANCED BY ERDF OPERATIONAL PROGRAMMES

Development and Experimental Performance Evaluation of a Dose-Rate meter for Pulsed Beam.

Contents. Session 12: Radiation detection technologies and radionuclide analytics Oral presentations S12

AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER

Stefano Colafranceschi

Deliberazione n.6/2013. Audit su Annual Progress Report del CERN. SEZIONE DI CONTROLLO PER GLI AFFARI COMUNITARI ED INTERNAZIONALI

E U R O P E A N C U R R I C U L U M V I T A E F O R M A T PERSONAL INFORMATION

Gli Eventi Preparatori al Forum 2010

ISTITUTO NAZIONALE DI FISICA NUCLEARE

arxiv: v1 [physics.ins-det] 14 Jan 2014

ITALIAN NATIONAL BLOOD CENTRE REGULATION OF CORD BLOOD BANKING: GLOBAL IMPLICATIONS

Assessment of environmental radiation monitoring data in Hungary following the Fukushima accident

Evaluation of 55-gallon Lead-Lined Calibration for the Gamma Modality of the High Efficiency Neutron Counter

PhD in Management, Production and Design Os&h in critical ATECO codified activities

International Intercomparison Exercise on Natural Radiation Measurements under Field Conditions

M. Marengo. Medical Physics Department University Hospital S.Orsola Malpighi, Bologna

BIC Lazio spa, Business Innovation Center, network of regional development agencies:

Rn, Rn and their progeny concentrations in o$ces in Hong Kong

Curriculum Vitae et Studiorum Dossier n Cinzia Di Giusto

PET and PET/CT in Clinical Trials

WORKSHOP LIGHT SOURCES

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

Dr. Eng. Adamo, List of publications Page 1 of 5

Nuclear applications at the Hellenic Centre for Marine Research (HCMR): Radioactivity in the marine environment

Dedicated computer software to radiation dose optimization for the staff performing nuclear medicine procedures

Ramon 2.2 Radon-Monitor

Industrial tracers - Finding leaks and blockages

Neutron Detection Setups proposed for

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Requirements and solutions for laboratory analysis software

WEBLAB - SCHEDA DOCUMENTO N 230

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Issue APPROACHES TO EVALUATION OF REGIONAL POLICY OUTCOMES. G. Marchesi, L. Tagle, B. Befani

Automated Laboratory Quality Assurance Program: Using the ORTEC GammaVision -32 Software

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Emission factors for Electric Energy in

RN-222 RELEASE TO THE ENVIRONMENT: COMPARISON BETWEEN DIFFERENT GRANITE SOURCES

Bert Windhorst Radiopharmaceutical scientist VU University Medical Center Amsterdam

Curriculum Vitae Et Studiorum

Uncertainty evaluations in EMC measurements

Quality Assurance Testing of AtomLab Dose Calibrators

Role and tasks of Arpa Piemonte in controlling and monitoring of ionizing and non ionizing radiation. G.. d Amored

AMEDEO ARGENTIERO Visiting Ph.D. Student, spring semester, Massachusetts Institute of Technology (USA)

Advanced Performance and Responsibility Guidelines for the Nuclear Medicine Technologist. SUMMARY. Introduction 2

SpectrAIR TM. spectroradiometer for environmental monitoring applications. Copyright Flyby s.r.l.

UNIVERSITY IN CLUJ Tamás NÉDA, Ildikó MÓCSY, Szende TONK Sapientia University Cluj, Environmental Science Department

Animal welfare during transport and related operations 21/24 June 2011 Italy. Tutors & International Organisation Delegates

PoS(PhotoDet 2012)068

2. OCGs and illegal markets

Transcription:

Report to the CCRI Section II on the activity carried out at the ENEA-INMRI on radionuclide measurements in the period 2003-2005 Marco Capogni and Pierino De Felice 1 Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti ENEA, C. R. Casaccia P.O. Box 2400, I-00100 Rome (Italy) 1. INTRODUCTION The present report summarizes the 2003-2005 activities carried out at the National Institute for Ionising Radiation Metrology (ENEA-INMRI) in the field of interest of CCRI Section II, i.e. radionuclide measurements. The main characteristics of the national standards maintained in Italy at the ENEA-INMRI in the field of radionuclide measurement are reported in the following table. National standards maintained at the ENEA-INMRI (Italy) in the field of radionuclide measurements Quantity Standard Radionuclide Uncertainty Range (^) (%) Activity (+) Measurement Range -n. 2 4πβ-γ coincidence counting systems β and β-γ emitters 0.1-3 (1-20) kbq -n. 1 NaI(Tl) well-type sum-peak coincidence γ γ emitters 0.5-3 (1-20) kbq counting system -n. 1 NaI(Tl) well-type 4πγ counting system γ emitters 0.5-3 (1-20) kbq -n. 1 LS (CIEMAT/NIST) counting system β and x-ray 0.6-3 (1-20) kbq emitters -n. 1 Rn-in-water generator 222 Rn-in-water 2 (200 10 4 ) Bq/dm 3 -n. 1 Electrostatic cell 222 Rn-in-air 1 (1-15) kbq -n. 1 Well-type ionisation chamber* γ emitters 0.2-3 (10-2 10 4 ) kbq -n. 3 HPGe γ-ray spectrometers* x and γ emitters 1-5 (1-10 5 ) Bq -n. 1 0.1 m 3 radon chamber* 222 Rn-in-air 2-10 (10 2-10 4 ) Bq/m 3 Activity concentration Surface -n. 1 2π windowless gas flow proportional emission rate counter (^) Rounded values for standard combined uncertainties (1σ). (*) High precision secondary standards. (+) Issue of radioactivity standards: Standard radioactive sources are supplied in different geometries in the activity α and β emitters 0.5-3 (1-20) s -1 concentration range from 10-2 Bq g -1 to 2 MBq g -1 (aqueous solutions in standard ampoule or in flask of different size) and in the activity range from 1 Bq to 20 MBq (sources in Marinelli beaker, in ampoule, on paper filter and point sources). The ENEA-INMRI programmes in the field of radionuclide metrology in the last two years (2003-2005) were focused, as in the past, on maintaining and developing the national standards for activity measurements and on the more general activities in the field of standardisation and quality-assurance in radioactivity measurements. The main specific activities carried out at ENEA-INMRI in this field are summarised below. 1 now at Joint Research Centre, European Commission, Ispra - VA (Italy) 1

2. DEVELOPMENT OF NATIONAL STANDARDS AND COMPARISONS Standardisation of 99m Tc A new measurement standard, based on the 4πγ high efficiency counting method, was developed in 2001 for absolute standardisation of radionuclides with complex decay scheme. A NaI(Tl) well-type crystal (125 cm x 125 cm) with accurately known geometrical parameters (uncertainty of 0.1 mm) was used. The new standardisation method was firstly applied at ENEA-INMRI during the 152 Eu BIPM comparison. In this case the single-photon detection efficiency curve, generated by Geant 3.21 Monte Carlo code, was used for calculating the specific nuclide counting efficiency by Winkler s NaJ5EF Fortran program. In 2004 the Monte Carlo code has been implemented in Linux environment. A new subroutine developed by Jean-Pascal Laedermann at the Institut de Radiophysique Appliquée and Office Federal de Metrologie (IRA-OFMET) in Switzerland, for simulation of radionuclide decay process was incorporated. The new code was used for calculation of the 99m Tc counting efficiency and for standardization of this nuclide particularly used in Nuclear Medicine. Standardisation of 18 F [ 18 F]Fluorodeoxiglucose(FDG) is the most successful and widely used radiopharmaceutical for Positron Emission Tomography (PET). In Italy, an extensive commercial production and distribution of FDG by Amersham Health Srl started 1 years ago. The radionuclide is produced by the Scanditronix MC40 Cyclotron of the EU Joint Research Centre in Ispra. To fulfil the growing request for 18 F measuring instruments calibrations, a research collaboration was started between the ENEA-INMRI, the JRC-Ispra and the Hamersham Healt Srl to develop the 18 F national primary standard. Because of its relatively short half-life (109.7 min), the 18 F standardisation was carried out on the production site by using the CIEMAT/NIST method. The analysis of measurement results indicated a 48 V impurity, produced in the Titanium target. Participation in the BIPM intercomparison on 125 I The sum-peak coincidence counting method was applied for absolute activity measurement of a 125 I solution in the frame of a BIPM international key comparison. The mother solution was initially checked for radionuclide purity. A number of sources for absolute measurements were then prepared in flame sealed glass ampoules containing 1 cm 3 of inactive diluent and increasing masses of 125 I mother solution (from 3.5 to 38 mg). These sources were counted in two experimental systems based on different high efficiency NaI(Tl) well-type detector (respectively 550 cm 3 and 1600 cm 3 ). Usual corrections for background and decay were applied. Single- (full-energy) and sum-peak superimposition was corrected by a linear extrapolation of the peak tails. Random summing and dead time effects were corrected by linear extrapolation to zero count rate (zero mass). This correction was drastically reduced thanks to the use of high performance digital multiparametric acquisition system (Fast Comtec PMA3), recently installed at ENEA-INMRI. The relative combined standard uncertainty of the ENEA-INMRI results was 0.3%. The results of the intercomparison are under evaluation by the BIPM. Standardisation of Radon in air The ENEA-INMRI primary standard for radon-in-air measurements, in operation since 1995, was renewed. An additional radon reference monitor, based on a Genitron AlphaGuard, was 2

installed in the system gas circuit. To this purpose, the monitor cell was modified with the addition of a gas flow adapter. The AlphaGuard monitor, thank to its notable stability of response and low humidity dependence, allowed recalibration of the radon reference atmosphere with lower uncertainty. 3. QA NATIONAL PROGRAMME AND CALIBRATION ACTIVITY Development of a 18 F transfer standard The number of 18 F calibration requests is growing in Italy, due to the increasing 18 F[FDG] use. A new portable well-type ionisation chamber was then acquired and calibrated by the ENEA-INMRI, using the newly developed 18 F primary standard. This new chamber will be used as a transfer secondary standard measurement system. It can be transported in Hospitals or in 18 F[FDG] production centres where local instrumentation can be calibrated by comparison. Calibration of radioactive sources Radioactive standards (liquid solutions, point sources, gas sources, paper filters and spiked reference materials for a total of about 100 sources per year) were provided for calibration of radioactivity measurement instruments in the country and for organisation of bilateral comparisons for QA. Calibration of radionuclide activity measurement instruments The measurement instrument calibration service has been active as in past years. Among these: 1. Extended calibrations were made for the 99m Tc measurement instruments of the children's Hospital "Bambin Gesù" in Rome 2. Calibration facilities were implemented in 2004 for the growing demand arising from a number of laboratories in the Country in the field of radon measurements. The ENEA-INMRI radon chamber and the radon-in-water standard were used for this purpose. 3. Calibration of surface contamination monitors were performed according to ISO standards. In the 2004-2005 period about 50 instruments were calibrated mainly with 241 Am, 90 Sr and 14 C sources. A new intercomparison campaign for the radioactivity surveillance network The main Quality Assurance program conducted by ENEA-INMRI in the field of radioactivity measurements regarded the national network for environmental radioactivity surveillance. The program is based on periodical calibration and intercomparison campaigns carried out by ENEA-INMRI under request of the National Agency for Environmental Protection. This program started more than 15 years ago. Beta counting and γ-ray spectrometry in environmental samples are the main objects of the program. This QA program was effective in reducing to about 10% the maximum deviation of the results among the network laboratories. A new national intercomparison campaign was carried out for γ-ray spectrometry measurements on spiked simulated filters. To this purpose about 60 sources were prepared and distributed to the participating laboratories. Results of the intercomparison are under evaluation by the ENEA-INMRI. 3

4. PARTICIPATION IN METROLOGICAL AND STANDARDISATION ORGANISATIONS Part of the time was devoted to activity in metrological and standardisation organisations: ICRM, BIPM/CCRI-II, IEC/TC45, ISO/TC85/SC2, UNI (National Standardisation Organisation). P. De Felice has continued his office as Secretary of the International Committee of Radionuclide Metrology. 4

5. STAFF Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti ENEA, C. R. Casaccia, P.O. Box 2400, I-00100 Rome (Italy) Director, Dr. R. F. Laitano Fax: ++39 06 3048 6097 Phone: ++39 06 3048 (EXTENSION) E-mail: username@casaccia.enea.it STAFF (2) E-mail username Phone extension Scientists Dr. P. De Felice defelice 3580 Dr. M. Capogni marco.capogni 6628 Dr. F. Cardellini francesco.cardellini 3084 Technicians Mr. A. Fazio fazio 3557 Mr. A. Manzotti (50%) (1) manzotti 4563 (1) Due to the shortage of personnel some technicians share their work (e.g., mechanical workshop) among the different sections of the Institute. (2) Administrative service and technical assistance for maintaining and repair are supplied by the CR Casaccia central service. Some activities at the ENEA-INMRI in the period 2003-2005 have been carried out with the collaboration of some students. 5

Technical reports and articles published in journals or in meeting proceedings in the period 2003-2005 on the activities carried out at ENEA-INMRI in the field of interest of CCRI (II): radionuclide measurements Sahagia M., Ivan C., Grigorescu E.L., Capogni M., De Felice P., Fazio A., Standardization of 65 Zn by 4πPC-γ coincidence counting method with efficiency extrapolation, Applied Radiation and Isotopes 60, N. 2-4, (2004) 423-427. Grigorescu E.L., De Felice P., Razdolescu A.C., Luca A., Ultra Low Level Gamma Spectrometry by Beta Coincidences, ICRM Conference on Low-Level Radioactivity Measurement Techniques, BEV, Vienna, Austria, October 13-17, 2003, Applied Radiation and Isotopes 61, N. 2-3, (2004) 191-195. Roca V., De Felice P., Esposito A., Pugliese M., Sabbarese C., Vaupotic J., The influence of environmental parameters in electrostatic cell radon monitor response, ICRM Conference on Low-Level Radioactivity Measurement Techniques, BEV, Vienna, Austria, October 13-17, 2003, Applied Radiation and Isotopes 61 N. 2-3 (2004) 243-247. Anagnostakis M., Bolzan C., De Felice P., Fazio A., Grisanti G., Risica S., Turtiainen T., Van der Graaf E., A preliminary intercomparison of gamma-ray spectrometry on building materials, ICRM Conference on Low- Level Radioactivity Measurement Techniques, BEV, Vienna, Austria, October 13-17, 2003, Applied Radiation and Isotopes 61 N. 2-3 (2004) 381-388. De Felice P., Mitchell P.I., Woods M.J. Eds., "Proceedings of the 14 th International Conference on Radionuclide Metrology and its Applications", ICRM 2003, Dublin, Ireland, 2-6 June 2003, Appl. Radiat. Isot. 60 2-4 (2004). Capogni M., De Felice P. "Dall'INMRI-ENEA nuovi campioni primari di radionuclidi β-emittenti", Tutto_Misure Anno VI N. 04, 365-366, 2004. Capogni M., De Felice P. and Fazio A., 32 P activity measurement. Description of the method developed at the ENEA-INMRI, CCRI(II) meeting, BIPM, Sèvres 25-26 November 2004. Capogni M., De Felice P. and Fazio A., 65 Zn activity measurement. Description of the method developed at the ENEA-INMRI, CCRI(II) meeting, BIPM, Sèvres 25-26 November 2004. De Felice P., Arginelli D., "Metodi di qualificazione delle analisi degli escreti ed interconfronti", 41 Corso della Scuola Superiore di Radioprotezione Carlo Polvani dell AIRP, ENEA C.R. Casaccia, 20 ottobre 2004. De Felice P., Battisti P., "Fantocci di taratura per misure dirette ed interconfronti", 41 Corso della Scuola Superiore di Radioprotezione Carlo Polvani dell AIRP, ENEA C.R. Casaccia, 19 ottobre 2004. De Felice P., "La taratura della strumentazione e la garanzia di qualità nelle misure di radon", relazione ad invito al Convegno "Il Radon, un gas quasi perfetto", organizzato dal Dipartimento Scienze Fisiche della Università di Napoli Federico II, Villa Orlandi, Anacapri, 5 luglio 2004. De Felice P., "Attività dell'inmri-enea sul radon", relazione ad invito al Convegno "Prevenzione dei rischi da radon negli ambienti interni e informazione della popolazione", Istituto Superiore di Sanità, Roma, 7 giugno 2004. Capogni M., Cardellini F., Ceravolo L., De Felice P., Fazio A., "Attività dell'inmri, nel periodo 2003-2004, nei diversi settori di interesse per i centri di taratura SIT: Settore misure radionuclidi", Riunione dei Centri di taratura accreditati dal SIT nel settore radiazioni ionizzanti, ENEA C.R. Casaccia, 4 maggio 2004. De Felice P., La metrologia dei radionuclidi presso l INMRI-ENEA, seminario presso la sezione di Pisa dell Istituto Nazionale di Fisica Nucleare, Pisa, 30 marzo 2004. De Felice P., Analisi dei risultati e delle incertezze associate, relazione a invito alla Giornata di Studio "Radon in acqua: i risultati", AIRP-ENEA, ENEA C.R. Frascati, 03 marzo 2004. 6

Cannatà V., Capogni M., De Felice P., Fazio A., Marracino F., Nuovo Campione Primario di 99m Tc usato per la taratura del calibratore di dose portatile dell Ospedale Pediatrico Bambino Gesù (OPBG) in Roma submitted and accepted to the 4 Congresso Nazionale dell Associazione Italiana di Fisica Medica (AIFM), 14-17 June 2005 Verona (Italy) Capogni M, De Felice P., Fazio A., Simonelli F., D Ursi V., Pecorale A., Giliberti C. and Kamel A., Sviluppo di un nuovo campione primario di 18 F per applicazioni in medicina nucleare submitted and accepted to the 4 Congresso Nazionale dell Associazione Italiana di Fisica Medica (AIFM), 14-17 June 2005 Verona (Italy). Capogni M, De Felice P., Fazio A., Simonelli F., D Ursi V., Pecorale A., Giliberti C. and Kamel A., Development of the Primary Standard for Calibration of 18 F[FDG] Activity Measurement Detectors submitted to European Physical Society 19 th Nuclear Physics Divisional Conference, New Trends in Nuclear Physics Applications and Technology, 5-9 September 2005 Pavia (Italy). 7