OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT



Similar documents

Sewerage Management System for Reduction of River Pollution

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

Phosphorus Removal. Wastewater Treatment

WASTEWATER TREATMENT OBJECTIVES

Advanced Wastewater Treatment Process

Removing Heavy Metals from Wastewater

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

POTW PHOSPHORUS REMOVAL PROCESSES

Environmental Technology March/April 1998

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

GUIDELINES FOR LEACHATE CONTROL

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

The City of Boulder 75 th Street Wastewater Treatment Facility

TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa

Phosphorus Removal. P.F. Strom, 2006; do not copy without written permission.

Wastewater Nutrient Removal

Cambridge Wastewater Treatment Facility

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

Engineers Edge, LLC PDH & Professional Training

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Iron and Manganese BACTERIA AND IRON AND MANGANESE

The Use of Magnesium Hydroxide Slurry as a Safe and Cost Effective Solution for H 2

THE NWF WATER PURIFICATION PROCESS FRESH WATER IN A NATURAL WAY. Esko Meloni Ferroplan Oy

Facility Classification Standards

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

HEXAVALENT CHROMIUM REMOVAL FROM INDUSTRIAL WATSEWATER BY CHEMICAL PRECIPITATION METHOD

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Appendix B: Water Treatment Scenarios from AMD Treat

Case Study: Treatment of alluvial sand, treatment of washing water and sludge.

Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD

NUTRIENT REMOVAL FROM SECONDARY EFFLUENT BY ALUM FLOCCULATION AND LIME PRECIPITATION*

Chemistry at Work. How Chemistry is used in the Water Service

Description of the Water Conserv II Facility

Ion Exchange Softening

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

Coagulation and Flocculation in Water and Wastewater Treatment

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

Water remediation: Passive Treatment Technologies

Coagulation and Flocculation

RESIDENTIAL TREATMENT SYSTEMS

5.1.3 Model of biological phosphorus removal

Phosphorus Removal in Wastewater Treatment

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

Small scale sewage treatment system with membrane bioreactor technology

REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

ACTIFLO Process For Wet Weather and Wastewater Treatment

Compact Sewage Systems in France A technical and cost comparison

Phosphate Recovery from Municipal Wastewater through Crystallization of Calcium Phosphate

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Orange County Sanitation District

Basic Chemistry of Chlorination

Best Practice in Boiler Water Treatment


STOCKMEIER water chemicals Strong bonds for clear water

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Toxic Municipal Waste Water Treatment

Technical Publication. Title: Using Online Analyzer for Optimizing Chemical Phosphorus Removal Process in Municipal Wastewater Treatment

BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.

2.0 PHOSPHORUS FORMS IN RAW WASTEWATER AND IN THE EFFLUENT 4.0 CHEMICALS USED FOR PHOSPHORUS PRECIPITATION Overview of Aluminum Based Chemicals

Pursuant to Department of Environmental Protection Rules Chapter 555, effective March 9, 2009

Planning, Designing, Monitoring and Inspection of Wastewater Treatment Systems of Industries

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

Floating Treatment Wetland Technology: Nutrient Removal from Wastewater

Appendix F Use of spill basin to further reduce final effluent variability - report

SECTION 6 EXISTING WASTEWATER MANAGEMENT SYSTEMS

Using Magnesium Hydroxide

Water Management in Helsinki. Water supply. Mikael Sillfors

The First Step in Effluent Treatment

WASTEWATER TREATMENT PLANT MAINTENANCE INSTRUCTIONS part 1

FLOTTWEG CENTRIFUGE TECHNOLOGY FOR THE EXTRACTION OF AVOCADO OIL Satisfying Customer Needs by Using High Quality Separation Technology

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

El Paso Water Utilities Public Service Board. Application for Renewal Industrial Wastewater Discharge Permit

Iron and manganese are two similar elements

TREATMENT OF SANITARY SEWER OVERFLOW

Control Technology, Advanced Treatment Processes, and Next-generation Systems for Sewage and Wastewater

Products, systems and services for water and wastewater treatment plants Enhanced plant performance, efficiency and reliability

White Paper. Chemical dosing and blending - the role of precision actuators

Appendix 2-1. Sewage Treatment Process Options

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Metal Ion + EDTA Metal EDTA Complex

Complete. Water Solutions. for Rural India

aquateam Aquateam - Norwegian Water Technology Centre A/S Report no: Project no: O Project manager: Dr. Bjørn Rusten.

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

lforrnation Requir C -INF lucture & OPER eraf - Drawing No Drawing No

Ground Water Contamination by Leachate

The Flow Regulator. Flow regulation

Who is responsible for making sure that wastewater is treated properly?

1.782 Environmental Engineering Masters of Engineering Project

FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: UT NEW PERMIT MINOR INDUSTRIAL

William E. Dunn Water Reclamation Facility. Facility Overview & Information

During the past decade, the city of

ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

Saudi Aramco Project Development

Transcription:

JAES_1(14)_1_2011 GLIGOR E., pp.67-72 SECTION Civil Engineering and Installations OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT GLIGOR Emil 1, IONESCU Gheorghe-Constantin 2, BLAGA Casian-Alin 3, DAN Florin 4 ARTICLE INFO Article history: Accepted: March 2011 Available online: July 2011 A B S T R A C T The effluent contains a range of pollutants, some of which are removed more or less conventional in the purification steps, while others are held very little or at all, in the conventional treatment plants. Acute problems of water protection have led to the imposition of the severe conditions of concentrations limit permitted to the effluent discharged into the natural emissaries. Keywords: ferric chloride, phosphorus, sewage treatment plant INTRODUCTION The treatment plant receives wastewater from the city of Oradea and the surrounding villages, being connected to the two main collectors: the ovoid 70/105 cm bell 165/260 cm. Wastewater from the municipality's lowlands are channelled in the 10 pumping stations, where they are pumped to gravity sewers. Upstream of the sewage plant is a pool of compensation for the flows during heavy rains, flows that go back into the main collector and are taken to the treatment station. To compensate for the lack of capacity (Q > 2200 l/s) and preventing of accidental pollution, there are downstream, biological treatment ponds ~ 50 ha, where water is discharged into the river Crisul Repede in a controlled way, and approved by the competent authorities [5]. 1 PhD. Student Eng., University of Oradea, Faculty of Architecture and Constructions, e-mail: gligoremil13@yahoo.com, Romania 2 Ph.D.Prof. Eng., University of Oradea, Faculty of Architecture and Constructions, e-mail: gheionescu@gmail.com, Romania 3 PhD Student Eng., University of Oradea, Faculty of Energetics, e-mail: cblaga@uorarea.ro, Romania 4 PhD Student Eng., University of Oradea, Faculty of Energetics, e-mail: florindanro@gmail.com, Romania

OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT The treatment plant is a mechanical-biological type, and purifies the domestic and industrial wastewater from Oradea and in some areas adjacent to the city, station effluent being discharged into the environment Crisul Repede, 10 km upstream from the point of crossing the border with Hungary. MATERIAL AND METHOD Given the fact that almost always wastewater treatment plant have a high investment value, it was necessary for the development of sludge processing norm NP 118-06/2006 treating sludge processing technologies retained and proposed treatment plants best parameters and methodologies for designing buildings and installations, and how the choice of machinery and equipment necessary to ensure that they are operating as a simple, safe, reliable, energy efficient, and to lend itself to automated processes treatment [1]. Automation of complex industrial processes required to ensure optimal functioning of these schemes, with minimal consumption of energy and materials, with a special security operation, was required in almost every industry today, and it represents not an option, but a necessity. In these circumstances, it was a necessary arrangement to ensure stable and optimal economic operation, remote operation of various components of complex processes, gathering, transmission, storage and processing large volumes of information, provision of interdependence between the various parameters of the process, to meet performance criteria at the global optimum. With the development of a computer system, is intended to provide certain requirements, it is necessary that both the design and its implementation to make in a short time, so, a cycle of low time of achievement, with significant savings of human and financial resources. Achieving this goal requires, besides a series of organizational measures, the increasing use of standard solutions [2]. The experimental research carried out in the Oradea Waste Water Treatment Plant revealed phosphorus concentrations exceeded maximum permissible limits, to remedy this shortcoming, the following operations are propose: Given the processes of removing phosphorus from wastewater by chemical addition, to the actual situation existing at Oradea Wastewater Treatment Plant, the following procedure to reduce the phosphorus chemical reagents using FeCl 3 (+ H 2 O) was proposed. As the concentration of phosphorus in the legislation in force should be max.1mg/l in the purified water, and after testing in the laboratory of

JAES_1(14)_1_2011 GLIGOR E., pp.67-72 SECTION Civil Engineering and Installations Oradea Wastewater Plant, it was found that this value was exceeded in most cases, reaching values between 2 and 2.5 mg/l, values well above the limit of NTPA001/2005 [4]. At Oradea Wastewater Treatment Plant, phosphorus is partially reduced with the existing biological technology, for maximum values to be within permissible limits, special measures must be taken. For this purpose it is necessary to install a dosing station of an aqueous solution of ferric chloride FeCl 3 (+ H 2 O) with an iron content of 14%. Phosphorus in dissolved form (PO 4 -P) is precipitated by iron ions, thus forming a heavy to dissolved precipitation. The precipitation slurry is decanted into the final settling and can be removed from the system. If the wastewater has a ph value between 6 and 8, then the following equation describes the reaction of stoichiometric composition: 3Fe 3+ +2PO 4 3- +3H 2 O(FeOH) 2 (PO4) 2 +3H + Fe 3+ +3H 2 O Fe(OH) 3 +3H + (1) Following this equation it can be stated that 1.5 mole of iron ions, to precipitate a mole of phosphorus. Depending on the technology station, the degree of interference may vary from one point to another in the wastewater circuit pathway on site. Determining the most favourable points it is for the designer. At Oradea Wastewater Treatment Plant the dosage point is most favourable at the end of aeration tank, the point before the secondary settling (the final). Thus we ensure that the chemical, mix completely, after dosing, this contributing to the formation of the precipitation optimum level, helping to deposit the sludge, which will reduce the phosphorus content of water to be discharged into the environment, below 1 mg/l. Central dosing pumps (a group composed of two pumps in operation + one backup) will be automatically controlled and the concentration of phosphorus in purified water will be analysed on-line, with a measuring apparatus before being discharged into the environment. If the phosphorus concentration increases, the dosing pump will respond immediately and will increase the quantity of reagent dosed, and if the concentration of phosphorus is reduced, will decrease the amount of chemical reagent determined. For a better result, it is necessary to introduce ferric chloride in the supernatant from the centrifuge of dehydration, which in turn is fed back into the treatment process circuit.

OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT Fig.1. Scheme of principle regarding the location of sensors and ferric chloride discharge points I- influent; CI- entrance chamber; GR- rare slats; GD- thick slats; D- sand descanter; SG- fat separator; DP- primary clarifier; SPAD-decanted water pumping station; BA- aeration basin, DS- secondary clarifier, E-emissary, G- gas meter; C- cogeneration; M- methane tank; B- biogas; NAP- sludge with polymer added; N- used sludge; CH- centrifuge hydration/dehydration; ND- dehydrated sludge; DP- layer storage; AN-water sludge; IN- sludge thickener; NE- excess sludge; PD- dosing pump; RFeCl 3- ferric chloride tank; PLC- programed controller; RSS- sensor signal receiver Advantages of using ferric chloride are as follows: -precipitation of phosphorus, -neutralization of low sulphur bonds that inhibits the nitrifying, -removing of suspended solids, -chemical oxygen demand reduction, -elimination of sulphur components that easily produce toxic and corroding gasses, -decreased oxygen consumption in the aeration tank and also the energy consumption of turbo air pumpers, -delay spread of filamentous formations and biogas desulphurization, to a lower factor of corrosion to engines that uses the gas [3].

JAES_1(14)_1_2011 GLIGOR E., pp.67-72 SECTION Civil Engineering and Installations Ferric chloride is a reddish-brown liquid, slight pungent odour, with freezing temperature at -37ºC, boiling point at 100ºC, with complete solubility in water, ph = 1, combustible, highly irritating and highly corrosive, strong damage to the metal. For this reason, it is necessary to use special plastic pumps for dosing. Staff coming in contact to the solution must use plastic utensils, to be equipped with rubber gloves, goggles, to avoid inhaling the gas, and storage and transportation will be made only in plastic. Dosing tank from where the dosing feeds will be made of high density polyethylene (HDPE) with a capacity of approximately 30m 3 and the admission of the pumps must be fitted with a filter to prevent clogging of the dosing pumps with dirt. It is estimated that the doses of ferric chloride used will range between 2% and 10% of dry matter and for Oradea Wastewater Treatment Plant it would be about 80 l/h. CONCLUSIONS Application of this technology is recommended for modern water treatment plants that have a low yield on nitrogen elimination, the main goal is finding the balance between nitrification and de-nitrification. The condition for an efficient de-nitrification is a low redox potential, on one side, and the presence of a larger proportion of dissolved CCO, on the other side. In nitrification case, it applies its opposite, so near the high redox potential is no need for dissolved CCO, or if there is, then you need a minimum level. This technology seeks to coordinate these two different conditions, however, its practical implementation, rests with the operator station. Most of the sludge resulting from wastewater treatment cannot be successful conditioned without the associated of ferric chloride with lime. Lime is used to correct the ph value, which must be larger than 6. Ferric chloride must be injected in the sludge before the lime, and the injection points of the two reagents should be separate. REFERENCES 1. IANCULESCU, O., IONESCU, GH. (2002), Waste Water Treatment, Matrix Rom Publishing House Bucharest. 2. IONESCU, Gh. C. (1997), Sewerage Installations, Didactic and Pedagogic Publishing House R.A. Bucureşti. 3. IONESCU, Gh. C., IONESCU Daniela Smaranda (2009), Phisycal and Chemical Techniques for Removing Nitrogen and Phosphorus from Residual Waters International Symposia Risk Factors for Environment and Food Safety & Natural Resources and Sustainable Development, Faculty of Environmental Protection, Nov. 6-7 Oradea.

OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT 4. *** (2005), TPA-001/2005 Standard regarding the limitations of pollutants in the industrial and city residential waste water, at the releasing in the effluents (H.G. no 352/2005). 5. *** Regulations of use and maintenance of S.E.A.U. Oradea (Oradea Waste Water Treatment Station).