C-more Remote Access with Apple ipad or iphone Tutorial

Similar documents
C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

EZ RMC Remote HMI App Application Guide for ios

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

Manual Wireless Extender Setup Instructions. Before you start, there are two things you will need. 1. Laptop computer 2. Router s security key

EMR Link Server Interface Installation

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

C-more Remote HMI App

EZ RMC Remote HMI App Application Guide for Android Devices

WorldExtend IronDoor 3.5 Publishing a Terminal Services Application

SATO Network Interface Card Configuration Instructions

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

Configuring a customer owned router to function as a switch with Ultra TV

ipad Installation and Setup

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Savvius Insight Initial Configuration

Multi-Homing Dual WAN Firewall Router

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

Lab Configuring Access Policies and DMZ Settings

Information Technology Services. Your mailbox is moving to the cloud. Here is what to expect.

Remote Desktop Services

Gauge Drawing Tool Slider Drawing Tool Toggle Button Drawing Tool One-Way List Drawing Tool... 8

Recommended Network Setup

STATIC IP SET UP GUIDE VERIZON 7500 WIRELESS ROUTER/MODEM

Phone: Fax: Box: 230

Lab Configuring Access Policies and DMZ Settings

Quick Start Guide Using OneDisk with the Tappin Service

WestermoConnect User Guide. VPNeFree Service

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

DDNS Management System User Manual V1.0

StarMOBILE Network Configuration Guide. A guide to configuring your StarMOBILE system for networking

D-Link DAP-1360 Repeater Mode Configuration

Lab - Configure a Windows 7 Firewall

Client and Server System Requirements

Software and Settings Instructions

How to setup PPTP VPN connection with DI-804HV or DI-808HV using Windows PPTP client

Setting up Wireless ipad Control of your DEWETRON Computer-based System

Technical Tips. Copyright SystemQ Ltd. Configuring a BT Home Hub 2.0 to Perform Dynamic DNS Updates

NovaBACKUP xsp Version 15.0 Upgrade Guide

AXIS Camera Companion Internet access

Remote Access Enhancements

How to put the DVR online

Using Cisco UC320W with Windows Small Business Server

SETTING UP REMOTE ACCESS ON EYEMAX PC BASED DVR.

Port forwarding and viewing your IP camera from the internet

Use this guide if you are no longer able to scan to Sharpdesk. Begin with section 1 (easiest) and complete all sections only if necessary.

Chapter 2 Preparing Your Network

Intel Unite Solution. Standalone User Guide

Dynamic DNS How-To Guide

Deploying Windows Streaming Media Servers NLB Cluster and metasan

DWL-2000AP. Before You Begin. Check Your Package Contents

1 PC to WX64 direction connection with crossover cable or hub/switch

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents

Using WebVPN (webvpn.childrens.harvard.edu) to access shared and P drives, access , and use Remote Desktop

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

GV-iView HD V1 for ipad

Optimum Business SIP Trunk Set-up Guide

NAS 224 Remote Access Manual Configuration

Deployment Guide: Transparent Mode

Application Note Configuring the UGate 3000 for use with ClipMail Pro and ClipExpress


Easy Setup Guide for the Sony Network Camera

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Dolphin Ocean Server and Dolphin Mobile Client Installation and Configuration instructions

Application Note #231 Revision B November Using a VPN Connection to Remotely Access Lutron Systems. Overview. Key Terms. Before You Begin...

Windows 8.1 VPN Setup for your Home Computer

Using SonicWALL NetExtender to Access FTP Servers

Preparing for GO!Enterprise MDM On-Demand Service

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

AirStation VPN Setup Guide WZR-RS-G54

CREATING AN IKE IPSEC TUNNEL BETWEEN AN INTERNET SECURITY ROUTER AND A WINDOWS 2000/XP PC

How to Remotely View Security Cameras Using the Internet

Symphony Network Troubleshooting

Configuration and Access of FTP Server

ios Deployment Simplified FileMaker How To Guide

Setting up Remote Desktop

Immotec Systems, Inc. SQL Server 2005 Installation Document

1. Hardware Installation

OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)

CHANGE NETWORK SETTINGS Technicolor TG582n

Configuring Routers and Their Settings

How to convert a wireless router to be a wireless. access point

OneLogin Integration User Guide

1. Introduction What is Axis Camera Station? What is Viewer for Axis Camera Station? AXIS Camera Station Service Control 5

Hosted Microsoft Exchange Client Setup & Guide Book

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

MultiSite Manager. Setup Guide

FTP Server Application Guide REV:

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

For paid computer support call

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

How To Use The Lutron Home Control+ App On An Ipad Or Ipod

Installation and Setup

Using Zistos PNSC over BGAN

NETWORK SET UP GUIDE FOR RVH1004/US411 RVH1008/US811 RVH1016/US st G/2 nd G/3 rd G UGI H.264 DVR. SUPPORTING ROUTER DLINK LINKSYS NETGEAR Belkin

The initial set up takes a few steps, but then each time you want to connect it is just a two set process.

Projetex 9 Workstation Setup Quick Start Guide 2012 Advanced International Translations

Lab - Configure a Windows Vista Firewall

Setting Up Your FTP Server

Setup Guide. An installation space and network environment must be prepared in advance.

Transcription:

C-more Remote Access with Apple ipad or iphone Tutorial

P a g e 2 Introduction: This script will walk you through the basic process of setting up the remote access with an Apple ipad with the Remote Access Application. The Remote Access Application must be purchased from the Apple istore for a cost of $4.99. The Remote Access feature however is included in the C-more Programming Software at no extra cost and requires no special PLC programming. You will also need version 2.73 or higher of the C-More Software for the remote access to function. Included in the.zip file are the files for the completed C-more project and completed Productivity 3000 program. **Attention: Before you begin any of the following tutorials, please follow these directions to configure your computer s Ethernet port. Ethernet Configuration: Go to: Start > Settings > Network Connections or Start > Control Panel > Network Connections: Double click on Local Area Connection Click Properties Scroll down until you see Internet Protocol (TCP/IP) then double-click on it Click use the following IP address Click on Use the following IP address and enter these settings: IP address: 192.168.1.100 Subnet mask: 255.255.255.0 Click OK on the Internet Protocol then Local Area Connection Windows

P a g e 3 Table of Contents: Remote Access... 4 Firewall/Router Setup... 7 Apple ipad/iphone Setup... 11

P a g e 4 Remote Access: The C-more Remote Access feature can be used on any C-more HMI with an Ethernet port. It allows users to monitor and control a C-more panel from a PC located anywhere in the world as long as the panel is connected to the internet. The connection, across the internet or a local network, is established via a web browser such as Internet Explorer. These procedures can be applied to any project you wish to view/control remotely. For demonstration purposes we will use the projects provided with this script. Please start by loading the project titled Tank Pump Application.adpro onto the PAC and opening its respective C-more project Tank Pump Application (basic).eap in the C-more Programming Software. Check the IP address of your C-more panel: Please make sure you see Ethernet Configuration on the first page of this script Go to Setup Touch Panel Network Click the Ethernet Port tab Configure your Ethernet settings as shown below: Open the tab titled Web Server Function Check the box labeled Web Server Function Here you can choose to set a username and password that will control any remote access to the HMI. This is the highest level of access security level in the Remote Access features. Open the next tab, titled Remote Access

P a g e 5 Check the box labeled Remote Access Server Function Note: If you have a direct connection through a hub or switch then there are no changes necessary for the IP Address section. If you have a Firewall/Router between them you must enter the public IP address in the box. This is the static IP of the Firewall/Router supplied by your internet provider. In the Log on Information section you can set up each of the three available Remote Access user accounts. First choose your permission level: View only: gives the remote user the ability to only view the screen active on the panel. Most restrictive View and Screen Change: gives the remote user the ability to view the active screen and change to different screens. Mild restrictiveness Full Control: gives the remote user the ability to view and control all screen based objects as if at the local site. Least restrictive Choose an account name and password for each account you wish to use. The User Restrictions category denotes how many separate computers can be connected to each account at the same time. For our purposes, only one is necessary. Note: Each Remote Access Account can support a maximum of 5

P a g e 6 simultaneous remote user connections at a time. This allows for a maximum of 15 remote users at one time if all three accounts allow 5 connections. The disable tag can be used to disable access to the specific account. It is Off by default but if switched to on, a remote user cannot log onto that account. The notification tag is Off by default but turns On when that user account is connected. This can be used to notify a panel operator that a remote user is currently logged on. That s it! Save your C-more project as Tank Pump Application (remote access).eap and transfer it to your panel. To use remote access open our internet browser. Type in the IP of your HMI and press enter. Click on Remote Access then click on the type of connection you are using. You will be given a window asking if you wish to save, run, or cancel a download which contains the information your computer needs for the remote connection. Open the file and log in using the information corresponding to the account you wish to use.

P a g e 7 Firewall Router Setup: If you have a Firewall/Router configuration you will need to configure your router to Port Forward communication to the C-More panel. This section details the settings that need to be made in your router. In order to access C-more inside of a firewall/router remotely either a VPN connection must be used or port forwarding must be setup in the router to allow the C-more Web Server and Remote Access application to get through. When a TCP/IP message is sent to a router, it reads both the destination IP address (public IP address) in the message and the destination port number. If the destination IP address is the correct address for the router, the router then looks at the port number to determine whether it should allow this message and where to route this message to. This is done by configuring a Port Forwarding table within the router configuration. The router will change the destination IP address of the message to the local IP address specified by the Port Forwarding table. In order to access the Remote Access application in C-more, you have to connect to the Web server first, so two port numbers will need to be specified in the Port Forwarding table for each C-more panel that needs to be accessed. The first port number is the web server port number. By default, this number is 80. When using a web browser, such as Internet Explorer, port 80 is implied without having to type this in manually. If a number other than port 80 is needed, this can be accomplished by simply adding :<port num> after the IP address. An example URL for the image shown below would be: http://10.16.23.146:80 The second port number required is the Remote Access port number. The default for this application is 11102.

P a g e 8 Once the user has chosen to run the Remote Access application from the C-more web server, the application will then communicate to the router with the specified Remote Access port number. So to accomplish the setup as shown above, the C-more Programming Software Touch Panel Network Web Server tab and Remote Access tab would be setup as shown below:

P a g e 9 In order to access an additional C-more panel on the same router using the same public IP address, use a different Web Server port number and Remote Access port number for each panel.

P a g e 10 The C-more Programming Software Touch Panel Network Web Server tab and Remote Access tab would be configured as shown below for the second C-more panel:

P a g e 11 Apple ipad/iphone Setup: Start by downloading the C-More Remote Access Application from the App Store on your iphone or ipad. Use C-More or AutomationDirect in the search of the App Store to find the application. The cost is only $4.99 which is a price to keep people, who cannot make use of this software, from downloading it. Once the application is installed verify that your Apple device is communicating with your network. If you have a local network verify that you are communicating with your local wireless access point. If you are going through a firewall/router verify that you have Internet access. Once you start the C-More Remote Access Application here are a few steps to get you communicating quickly: Click the Connection button in the upper left corner. Click Input IP Address and enter the IP address of your C-More Panel You will now be prompted to enter Username and Password if you configured a Username and Password. Enter the Username and Password and click OK. Now you should be linked with you C-More panel. You will see an Unlock button on the screen. This button was used to prevent unintentional key presses. Double click the Unlock button to gain full control of C-More panel. For more detailed information please reference this document on the ADC website: http://c-more.automationdirect.com/remote_hmi/630.pdf