Why do our customers make their choice for PMT Partners Medische Techniek BV?



Similar documents
Clinic Washer-Disinfectors. Washer-Disinfector Line

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Hospital Sterilizers. T-Max Line

Company background and. portfolio overview

LABOKLAV. Autoclaves Made in Germany.

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

German engineering under high pressure

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

BSL3 and BSL4 Autoclaves. Laboratory Line

FVA/A1 saturated-steam sterilizer

Large Steam Sterilizers for the Life Sciences. Laboratory Line

Laboratory- and sterilisation equipment HMC EUROPE

Tabletop Line. Automatic and Semi-Automatic Autoclave Series

Laboratory- and sterilisation equipment HMC EUROPE

Horizontal Steam Sterilizers. Healthcare Line. Since

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Sterilizers with extra class

Laboratory & Scientific Line. Horizontal Steam Sterilizers

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

Medical Waste Autoclaves. Medical Waste Autoclaves

Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

AUTOCLAVE STEAM STERILIZERS

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Steam Sterilization Cycles for Lab Applications

Freezers - Ultrafreezers. Platilab & Irilab Series

Questionnaire Pure Media Systems

OT 40L / 90L. Laboratory Steam Sterilizers

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

TRADE AUTOCLAVES FOR STERILIZATION

Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization

GetinGe 88-SerieS WaSher DiSinfectorS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Specifications. Amaro 5000 & Steri 21 MD009/04 EN. A. J. COSTA (IRMÃOS), LDA. Desde 1953 ao Serviço Médico-Hospitalar

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.

The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series

Incubator with mechanical convection

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

The Power of Innovation. For better Sterilization. Pass-through autoclaves: Systec D-Series 2D Horizontal front loading bench-top autoclaves: Systec

Cooking at the Speed of light!

PBX Series Quick Fit Connector Bimetallic Steam Traps

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

LyoBeta. R+D Freeze-Dryers

Steripro cgmp. Steam Sterilizers

Systec Laboratory Autoclaves

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Heating oven with mechanical control

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

STEAM STERILIZERS FOR THE LIFE SCIENCES MADE IN THE USA

Material test chamber with mechanical convection

Heating oven with mechanical convection

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Power consumption (kw)

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

PORTABLE AIR CONDITIONER

AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Climate chamber with illumination

MELA quick 12+ Compact. Fast. Strong.

Vacuum drying oven for non-flammable solvents

Professional dishwashers. Blue line. the environmentally friendly brand

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

EcoCWave. The all-round talent for aqueous part cleaning.

LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific

GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ECOCIAT. Domestic hot water heat recovery unit

Oil and Coolant Circulating Heating System. Model - OCSM

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

HVAC air curtains. Type InduAir

James M. Pleasants Company

GenStore Archive Cabinet

Penetration tests according to the ISO 11140

Thermostatic Equipment

Engineered Solutions

Saferand easierinstallation

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Medical Market Laboratory EMEA

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

CRAC Precision climate control units for data centres

Touchclave-Lab... the revolutionary new range of square-section laboratory sterilizers from LTE Scientific

OPSIS LiquidLINE KjelROC Distillation Unit

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

FOF INDUSTRIAL SATURATED STEAM STERILIZERS

Operators manual Basic water heater

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

HEAVY WATER LEAK DETECTOR

SWIMMING POOL HEAT PUMP Owners Manual

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Transcription:

Why do our customers make their choice for PMT Partners Medische Techniek BV? Company presentation 2014

CONTENT Description Page Introduction... 3 Why the choice for PMT Partners Medische Techniek BV?... 4 Training and education... 5 The product range... 6 AQUA ULTRA Pre rinsing tables... 7 DUTCH STERILIZER Sterilization equipment... 8 Types standard models... 9 Steam sterilizer for Medical devices... 9 Steam / destruction sterilizer for laboratory... 9 Air cooled ventilator sterilizer for pharmaceutical purposes...10 Hot water sterilizer for pharmaceutical purposes...10 Combi sterilizer for pharmaceutical purposes...11 Technical description...11 Frame...11 Sterilizer chamber...12 Doors...12 Seal...13 Insulation...13 Panelling...13 Valves and plumbing...13 Meters and instruments...13 Vacuum pump and condenser...13 Heating...14 Air...14 Cabinet for the electrical parts...14 Twincom control and registration system...15 Digital approval of the process...16 Air detector:...17 Loading methods...18 Pass through cabinet...18 Transport trolley...18 Transport trolley height adjustable...19 Loading platform...19 Loading cart...20 Loading rack for baskets or platforms...20 Basket loading system...21 Chamber rails...21 Automatic loading and unloading system for baskets...21 Automatic loading and unloading unit...22 Technical specifications high efficiency steam sterilizer DS2000HR...23 Technical specifications high efficiency steam exchangers or electrical steam generators...24 LUPOO...25 TOPCARE Stainless steel working tables and trolleys...26 Working tables in several models:...26 PMT Partners Medische Techniek BV: 2014 2/27

Introduction Over 40 years ago, when founding PMT Partners Medische Techniek BV, I wanted to create a company which would be able to support the customers with quality and custom made solutions. We know no concessions in our products but we always aim at achieving a high quality and reliable products to ensure that the joy of using them will last after buying them during the whole lifetime of the products and it will not be disturbed by failure or high costs of repairs. No unnecessary equipment which isn t used but only these extras which will replace the already extensive standard equipment. In this way we can supply our customer with a complete range of sterilizers which satisfy the specific user s wishes without an exorbitant high price. Our success is proven in practice every day. PMT Partners Medische Techniek B.V. is certified according ISO 9001 & ISO 13485 and produces sterilizers under the brand name DUTCH STERILIZER. These sterilizers are manufactured in our own factory under the CE certificate for medical devices. Both our sterilizers and our washer disinfectors are equipped with an under private label developed operating system. If desired we can also provide you with a solution for the production of steam. Steam generators whether electrical or steam heated are within our product-line. Advanced solutions for the pre-rinsing and ultrasonic cleaning of instruments, free standing tables or other models are in the production program as well. Our client s wishes are also taken into account and considered thoughtfully, for instance automatic lifting systems or complete electrical height adjustable. Whether it is only about one small machine or a complete CSSD, PMT Partners Medische Techniek is willingly to share its knowledge with you. We can also support you in the maintenance and the validations of your precious machines. We do not only have the right knowledge and gear but we have a wide experience too. PMT Partners Medische Techniek B.V. has every knowledge and experience needed or required to be your partner in medical, pharmaceutical or laboratory equipment. Herman Schouwenburg Director PMT Partners Medische Techniek BV: 2014 3/27

Why the choice for PMT Partners Medische Techniek BV? Although there are more suppliers on the Dutch market for CSSD equipment, the majority is not able to totally develop, produce and maintain under own management Due to this combination and our knowledge from the past, we are capable to see the consequences of malfunctions of the installations and not just repair but look for solutions. This is not only a great benefit, which can t be seen right away but will most certainly be noticed during the daily work in the future. One of these benefits is that all communication runs directly by PMT with always a quick response and the right reaction. Because there is only one service-point! For our international market we are always looking for the right partners who work according to the same standards as we work in the Dutch market because this is how we have grown over the last years. An overview of the benefits for you as a customer: Spare parts directly available from our storage Standard products as well as custom-made Employees who speak the same language as the customer Flexible in achieving our work, no eight till five mentality The customer comes first Both maintenance, service, and validation under own management possible 24 ours, 7 days a week available, technician present within 24 hours after a report of a malfunction All equipment, whether it is a sterilizer or a washer/disinfector, is maintained by our own department, not only our own products but also equipment from other manufacturers. Off course PMT Partners Medische Techniek has all the necessary certificates to manufacture and maintain all the equipment they produce. PMT Partners Medische Techniek BV: 2014 4/27

Training and education Working with new equipment asks a lot of your employees, new technology can cause failures and this is what both you and us want to prevent. We as PMT Partners Medische Techniek have seen this problem and have taken our responsibility by creating a special service for our customers, which fully fits our philosophy how to cooperate with our customers. Training: Certificate of experience Before installing our equipment we offer our customer a training in their new equipment. Whether it concern a technician or a user a training on every level can be given. At the end of the training there will be a test and if passed for this test a Certificate of experience is given and also an entering code for using the equipment. In this way you are convinced that the people who are going to work with the new machines know what they must do. Education: Certificate of participation; There have been a lot of changes and developments over the last few years regarding education but there is still a need to preserve the knowledge in the daily practical situation. To play a part in this we have developed an education program for several subjects regarding equipment on a CSSD. In an overview : Different subjects regarding rinsing, disinfection and sterilizing Meant for all disciplines who work in one of these areas Duration of the education about 45 minutes Participants will get a Certificate of Participation ( can be placed in their personal file ) PMT Partners Medische Techniek BV: 2014 5/27

The product range In more than 40 years of experience in rinsing, disinfection and sterilizing, PMT Partners Medische Techniek BV has been able to represent itself as a respected manufacturer of rinsing-, disinfection and sterilization equipment for laboratory, pharmaceutical and medical purposes PMT Partners Medische Techniek BV is certified according ISO 9001:2000. under our brand name Dutch Sterilizer we manufacture both sterilizing as well rinsing- and disinfection equipment. Everything is produced in our plant in the Netherlands in compliance with the CE certificate for medical devices. We also supply advanced solutions for the pre-rinsing and ultrasonic treatment of instruments, completely with automatic lifting systems and height adjustable. If it is just a single application or the entirely development of a CSSD department, PMT Partners Medische Techniek BV is at your service with its knowledge Besides these standard High efficacy steam sterilizers for Medical, Pharmaceutical en Laboratory purposes, PMT also develops and produces custom-built sterilizers in different sizes. Process - design Own development department Manufacturing Service / maintenance ISO 9001:2000 certified DUTCH STERILIZER Sterilizers AQUA ULTRA Rinsing and Ultrasonic equipment TOPCARE Storage, working tables and trolleys Dutch Sterilizer washers / disinfectors : Instruments washer / disinfectors Cart washers Endoscope reprocessors Laboratory machines Dental machines Bedpan washers Animal cages Bed and OR tables washers PMT Partners Medische Techniek BV: 2014 6/27

AQUA ULTRA Pre rinsing tables PMT Partners Medische Techniek supplies complete Aqua Ultra pre rinsing tables, custom made These tables can be provided with: Working area Manual pre-cleaning unit Automatic pre rinsing unit Ultrasonic unit Storage area Working area Storage area Manual pre-cleaning unit Automatic pre rinsing unit Ultrasonic unit PMT Partners Medische Techniek BV: 2014 7/27

DUTCH STERILIZER Sterilization equipment HR The DS 2000 HR High efficiency steam sterilizer with high highly sophisticated control and registration system, its light weight round chamber and water saving system fulfils completely the economic en environmental demands of modern times. Using the latest technology and materials, the DS 2000 HR is an high level product, complying with national and international guidelines. PMT Partners Medische Techniek is certificated according ISO 9001: 2000 en ISO 13485, for designing, production and supplying steam sterilizers and steam generators. The sterilizers are provided for the use of clean steam according the guidelines and are manufactured under the CE certificate for medical devices. Depending of the purpose this can be the European Medical Directive 2007/47EG (93/42/EEG) or the guideline for machines. The sterilizer is also according to the European norms, such as EN 285 and EN-ISO 17665 (former EN 554). The laser welded sterilizer chamber is made of stainless steel, AISI 316L. The sterilizer is designed for pressures from 1 Bar vacuum, ( 0 kpa.abs) till +3 Bar (400 kpa.abs). The construction complies the Pressure Equipment Directive 79/23/EEC. The sterilizer can be supplied in both single doors or double doors ( pass through version). Different types and applications: Steam sterilizers for medical devices Steam/destruction sterilizers for laboratory Combi sterilizers for pharmaceutical purposes Air cooled ventilator sterilizers for pharmaceutical purposes Hot water sterilizers for pharmaceutical purposes Unique for the pharmaceutical purposes is our possibility to choose a program by product code. After typing the product code and charge code on the terminal, the sterilizer will automatically choose the right process. All our sterilizers can be provided with electrical or steam heated clean steam exchangers. PMT Partners Medische Techniek BV: 2014 8/27

Types standard models Sterilizers with round chamber: DS 2000HR 4.4.6 450 x 450 x 650 mm (volume 130 liter) DS 2000HR 6.6.6 660 x 640 x 650 mm (volume 275 liter) DS 2000HR 6.6.9 660 x 640 x 1.000 mm (volume 420 liter) DS 2000HR 6.6.12 660 x 640 x 1.250 mm (volume 528 liter) DS 2000HR 6.6.16 660 x 640 x 1.750 mm (volume 720 liter) All types in single door (SD) or double door (pass through) (DD) version. All other models or volumes are custom made on request of the customer. Steam sterilizer for Medical devices The Dutch Sterilizer Steam sterilizer is designed for sterilizing medical devices. The sterilizer is made for the use of clean steam according the guidelines ( EN285) and is manufactured under the CE certification in compliance with the guidelines for medical devices. The steam processes are based on an effective removal of air, necessary for a reliable sterilization of a load. For the drying of this load, the sterilizer has a jacket which covers almost the total surface of the chamber. The sterilizer has standard programs: Sterilization 134 C / 4 minutes, for Instruments. Sterilization 121 C / 15 minutes for Instruments Air removal and steam penetration (Bowie & Dick)- program 134 C / 3,5 minute Automatic air tightness test program Extra programs, optional: Prion program Prothese program Special program on request Steam / destruction sterilizer for laboratory The Dutch Sterilizer Steam / Destruction sterilizer from PMT Partners Medische Techniek BV is especially designed for a maximum of flexibility, reliability en the effective destruction of micro-biological waste and the sterilizing of feeding media and liquids in laboratories. PMT Partners Medische Techniek BV: 2014 9/27

The area of application of this sterilizer is for instance: - Sterilization of liquids in not totally closed containers like bottles - Sterilization of rinsed utensils like empty glass and porous materials - Disinfection of contaminated goods like cloths, petri-dishes and others - Destruction of contaminated waste like used petri dishes, even when they are packed in bags or containers The Dutch Sterilizer Steam / Destruction sterilizer is built according the current Dutch guidelines for sterilization (amongst EN285 / B0115), the Sterlab -demands and all rules for pressure equipment (PED 79/23/EEC). All the pressure-parts are made of at least stainless steel AISI 316L. Air cooled ventilator sterilizer for pharmaceutical purposes An air-cooled ventilator sterilizer is used for those materials which cannot be sterilized in a hot water sterilizer. It is possible to sterilize with just steam or with a steam-air mixture with ventilation. During the post-vacuum (= drying) phase of a steam-air mixture sterilization process the sterilizer is cooled down by filtered air 0,01 micron and a cooled down jacket which gives a very good drying result. The ventilator is powered by a electro-motor with a water-cooled axseal and designed for the best spread of the steam-air mixture during the process. The flow of the mixture goes up through the load and goes down at the jacket of the chamber. If only a steam process is used, the sterilizer acts just like a normal sterilizer for medical devices,. We know that it is not just the sterilizer itself, but the whole work-flow is important, the procedures, responsibilities, production, GMP-norms and the connection to a PC or network for storage of all process-data. The advanced, developed by PMT Partners Medische Techniek BV, Twincom control and registration system for pharmaceutical sterilizers, gives a undisturbed work-flow and has several tasks built in for your present situation and prepared for developments in the future. Hot water sterilizer for pharmaceutical purposes A hot water sterilizer, or raining sterilizer, is suitable for the sterilization of closed bottles, bags, ampoules en utensils. It is possible to sterilize by a standard steam-sterilization process or by the raining principal. The Dutch Sterilizer hot water sterilizer from PMT Partners Medische Techniek BV is designed for a maximum flexibility, reliability en the best treatment of the products to be sterilized. The processes are according to the wishes of the customer. When sterilizing according to the raining=-principal, a part of the sterilizer is filled with demineralised water (conductivity 15 μs/cm / silicats < 3 ppm. PMT Partners Medische Techniek BV: 2014 10/27

The water is heated by the use of a circulation pump and a heat-exchanger and equally spread over the load. The flow of the medium takes place from high to low. After sterilization the load is cooled down quickly by the heat-exchanger. Combi sterilizer for pharmaceutical purposes Another breakthrough in the range of pharmaceutical sterilizers by PMT Partners Medische Techniek BV is accomplished! Our latest product, the Combi sterilizer, is a combination of three sterilizers in one!! Steam sterilization with deep vacuum (Medical devices), steam/air sterilization by ventilation (air-cooled ventilator sterilizer), sterilization with hot water ( raining - sterilizer) and therefore large savings in money and costs of validation and maintenance. The Dutch Sterilizer Combi autoclave from PMT Partners Medische Techniek BV is mainly designed for hospital pharmacists with small production or special products. The sterilizer is built as a hot water and air-cooled sterilizer in a pass through version with steam heated and water-cooled jacket.. By combining all these aspects from different types of sterilizers, it is possible to sterilize a large range of products, such as: - Glasses filled with liquid - poly-propylene bottles and bags ( 50 ml till 3000 ml) - Ampoules (steam process with a linear descending deep post vacuum). - Eye drops bottles (steam process with special post vacuum, HEPA filtered air-cooling down to prevent boiling of the load). - Utensils (steam process with pre- and post-vacuum). The processes are defined in cooperation with the client and can be reproduced. Technical description Frame The sterilizer is built in a frame of stainless steel profiles, quality AISI 304 (DINnumber 1.4301). The sterilizer can be placed directly on the floor and easily be put in the right horizontal position by using the feet for adjustment. A special construction of the building is not needed, the sterilizer can be provided of a leaking tray. PMT Partners Medische Techniek BV: 2014 11/27

Sterilizer chamber The sterilizer chamber is designed and produced according to the Pressure Equipment Directive (PED) 97/23/EG. The design pressure pf the construction is 0 400 kpa (-1 3 bar). The sterilizer chamber, gasket and doors are made of acid proof stainless steel, quality AISI 316 L. The chamber is round shaped and has a heating jacket which almost covers 100%. The inside of chamber and doors are polished ( < Ra0,8 µm). Inside the chamber a stainless steel plate is placed for a good distribution of the steam. The chamber also has a special connection, ¾ BSP outside, for inserting the cables used for the validation. In case another connection is needed, this can be provided in discussion with the client. Between the door and the chamber, a silicon seal is used to exclude the sterilizer. Doors The doors are made of acid-proof stainless steel, AISI 316 L, and are consolidated by a stainless steel construction on the outside. By putting compressed air into a cylinder which is inside the door, the door closes in a vertical direction. The doors are provided with a mechanical safety in the top of the door. The safety starts working if there is any obstruction between the door and the chamber ( personal safety) If the safety is activated, the door opens immediately. The doors on the unloading side ( in case of a pass through version) can only be opened after a correct process. Both doors cannot be opened at the same time. PMT Partners Medische Techniek BV: 2014 12/27

Seal The sealing is achieved by a round shaped silicon gasket, the material of the silicon is according FDA 177.2600, USP Class VI. The seal guarantees an absolute air-tightness of the chamber. By putting compressed ait behind the gasket, it is pushed against the door, the pressure is constantly guarded, in case of a leakage, the process will be stopped and registrated as a failure. Insulation The chamber is insulated on the outside by a special insulation blanket, consisting of rock wool and heat-foil. The doors are also insulated but in this case the insulation is covered by stainless steel. The insulation is complies international standards. The front of the sterilizer has no parts with a higher temperature than 50 C. Panelling The sterilizer fronts are covered by polished (grain 360) stainless steel plates (DIN 1.4301, AISI 304) with a thickness of 1.25 mm. The covering can easily be removed whenever this is necessary. Valves and plumbing All parts in contact with steam are made of stainless steel. All other plumbing is made of red-copper, all other valves are made of brass or bronze. Water and compressed air are controlled by magnetic valves, other valves are guided pneumatically. Meters and instruments - Combined pressure vacuum meter (inside chamber), DIN class 1.6, 0 400 kpa. - Combined pressure vacuum meter (jacket) DIN class 1.6, 0 400 kpa. - Touch-screen display on the loading side and display on the unloading side in case of a pass through version. Vacuum pump and condenser The sterilizer is provided with a vacuum pump of the necessary capacity, the pump is built together with a electric motor. To prevent the pump against overheating, a stainless steel condenser is placed in the plumbing before the pump. This condenser is a stainless steel plate-cooler, type Alfa-Laval, AISI 316 (DIN number 1.4401). This condenser will be connected to ( preferred softened) water. If available, the condenser can also be connected to a cooling water network. The cooling will only take place if necessary, if steam is in the chamber and the vacuum valve is opened, the condenser starts. If the vacuum valve closes for letting in steam again, the condenser also stops. PMT Partners Medische Techniek BV: 2014 13/27

During the drying phase when a pressure of 7 kpa is reached, the valve is closed because there is no more chance for overheating. The vacuum pump is connected to a stainless steel break tank. Heating Heating by house-steam of 350 kpa, steam quality according the European norms (feeding water and condensate EN 285 Appendix B). The steam supply must be secured by a officially approved safety of 3 Bar. Within two meters of the sterilizer a condensation-pot will be installed in the steam piping. According to the EN 285 24.1, the amount of non-condensable gasses must be less than 3,5%. The fluctuation of the pressure must be no more than +/- 10%. Air After the drying phase the pressure inside the chamber will be restored to the environmental value by a valve. By this valve and a sterile filter of, 0,2μm air from the technical department will enter the chamber. After reaching the atmospheric pressure, the compressed air behind the gasket is removed and the door can be opened. Cabinet for the electrical parts All elements like PLC's, metering devices, safeties clambs, wiring and others are placed in a steel cabinet, manufacturer Rittal, model IP55, resistant against a relative humidity of 90%. PMT Partners Medische Techniek BV: 2014 14/27

Twincom control and registration system The sterilizer is provided with the Twincom control- and registration- system. This system consists of two fully independent microprocessors, one takes care of the control of the sterilization processes and the other grades the processes by a measure values control system. In this way an independent registration of the processes is guaranteed. The total control and registration system has been tested for the CE-certifying, including EMC, and is not effected by external influences. In the front of the sterilizer, a 5.7 TFT or 12 TFT colour touch screen is mounted on which all information is shown, for instance, process data, graphics, current temperature, current pressure in the chamber. The use of the touchscreen is easy and gives a clear overview. The touchscreen is also used as a interface to program. At the unloading side (in case of a pass-through model) there is a LCD display which shows several cycle information, for instance cycle phase, chamber temperature & pressure and other information which asks for a action from the user. In case a printer is attached, the process data can be printed on paper. In case a central PC is used, a connection to the sterilizer is possible by using the software package PMT Logboek On this Windows PC at least the following is possible: - Display of processes/status of all attached sterilizer on one screen. - Process graphics and all process data each sterilizer, including sterilizer number, chosen cycle, user, date, time, temperature- and pressure and malfunctions. - Digital registration and storage of all processes during at least 1 year/sterilizer - Historical display and reprint of storage cycles. - Direct connection to a colour printer. - Possibilities for connection with a track and tracing system - Machine is connected by RS232 or Ethernet (LAN) In case of a central PC the track and tracing system is only connected by this PC PMT Partners Medische Techniek BV: 2014 15/27

Digital approval of the process PMT Partners Medische Techniek BV: 2014 16/27

Air detector: Described in EN285 19. Checks air removal, leakage of air and non-condensable gases. Is a approved method. In Great Brittan and Ireland it is obliged to have an air detector on the sterilizer Is rather simple. Guiding system and construction must be suitable to attach the air detector. Working is validatable. Runs automatically every cycle. Gives a warning in case of malfunction. No need for Helix test materials. PMT Partners Medische Techniek BV: 2014 17/27

Loading methods The choice for a certain model of a sterilizer depends on both the needed capacity and on the other hand of the choice for a logistic system. Underneath there are some possibilities of loading methods for sterilizers. Beside this there are also possibilities for other solutions and combinations like for instance car-in-car-systems With the choice of the method of loading, a pass-through cabinet for the return of the racks is needed. Loading platform Loading rack for baskets Basket system Automatic loading and unloading system Transport trolley / transport trolley height adjustable Pass through cabinet For returning the loading trolleys to the loading side, a pass through cabinet can be installed next to the sterilizers. The cabinet has two doors which cannot be opened at the same time. Transport trolley To move a load to the sterilizer a transport trolley can be used. The trolley is made of stainless steel AISI 304, quality DIN-number 1.4301, The trolley consists of two rails for the load, a lock for the load, a lock for connecting the trolley to the sterilizer and four wheels of which two are movable and with a brake. PMT Partners Medische Techniek BV: 2014 18/27

Transport trolley height adjustable The loading of the sterilizer takes place by using a height adjustable transport trolley. Two buttons for high and low positioning activates the electro-motor. The motor uses a rechargeable battery which can be loaded with a loading device.. The trolley is made of stainless steel AISI 304, quality DIN-number 1.4301, The trolley consists of two rails for the load, a lock for the load, a lock for connecting the trolley to the sterilizer and four wheels of which two are movable and with a brake. The loading height of the trolley is from 600 to 900 mm. Loading platform On top of the transport trolley, a loading platform can be used for the goods to be sterilized The platform is made of stainless steel AISI 316, quality DIN-number 1.4401, The platform is provided with heat-resistant wheels. On the platform basket or containers can be placed. PMT Partners Medische Techniek BV: 2014 19/27

Loading cart On top of the transport trolley, a loading cart can be used for the goods to be sterilized The cart is made of stainless steel AISI 316, quality DIN-number 1.4401, The cart is provided with heat-resistant wheels. On the platform basket or containers can be placed. The loading car is provided with a bottom shelf, a top shelf and optional with a moveable shelf between the top and the bottom shelf. Loading rack for baskets or platforms For loading the sterilizer a loading rack can be used. The rack is made of stainless steel AISI 316, quality DIN-number 1.4401, The baskets or platforms can be placed in this loading rack. Depending of the size of the sterilizer, several baskets can be placed in the length of the rack. PMT Partners Medische Techniek BV: 2014 20/27

Basket loading system On top of the transport trolley, a basket loading system can be placed. The system is made of stainless steel AISI 316, quality DIN-number 1.4401. The baskets are placed on a platform, lifted up and rolled into the sterilizer. Inside the sterilizer the baskets are placed on a rail and the platform will be returned to the transport trolley. When using this system, there is no need for a pass through cabinet. Chamber rails In combination with the basket loading system and two rails are installed inside the sterilizer. The baskets are placed on these rails the baskets. The rails are made stainless steel AISI 316, quality DIN-number 1.4401 Automatic loading and unloading system for baskets The loader/unloader is made of stainless steel AISI 304, quality DIN-number 1.4301, The loader/unloader is based on the same principal as the basket loading system by hand. PMT Partners Medische Techniek BV: 2014 21/27

Automatic loading and unloading unit The sterilizer will be provided by a system for automatic loading and/or unloading of the loading platform, the loading cart or the loading rack The loader/unloader is made of stainless steel AISI 304, quality DIN nr. 1.4301.. PMT Partners Medische Techniek BV: 2014 22/27

Technical specifications high efficiency steam sterilizer DS2000HR Dimensions Dutch Sterilizer DS 2000 HR model 3.3.6. 4.4.6. 6.6.6. 6.6.9. 6.6.12. 6.6.16. Chamber ltr 125 180 360 542 725 907 Effective volume ltr 85 120 295 430 565 700 Sterilization units STE 1 1.5 4 6 8 10 Dimensions.single door (hxwxd) Dimensions double door (hxwxd) mm mm 1700 x 800 x 925 1700 x 800 x 940 1800 x 980 x 940 1800 x 980 x 1000 1950 x 1350 x 940 1950 x 1350 x 1000 1950 x 1350 x 1240 1950 x 1350 x 1300 1950 x 1350 x 1540 1950 x 1350 x 1600 1950 x 1350 x 1940 1950 x 1350 x 2000 Weight kg 450 550 650 700 750 850 Heat loss W 1000 1150 1350 1400 1450 1520 Ventilation m³/h 200 240 280 300 320 340 Consumption per cycle Dutch Sterilizer DS 2000 HR model 3.3.6. 4.4.6. 6.6.6. 6.6.9. 6.6.12. 6.6.16. Steam kg 3 4 6 8 10 12 Compressed air ltr 160 160 200 200 200 200 Cold water ltr 125 150 175 200 225 250 Electrical kw/h 1 1 1 1 1 1 Top consumption Dutch Sterilizer DS 2000 HR model 3.3.6. 4.4.6. 6.6.6. 6.6.9. 6.6.12. 6.6.16. Steam kg/h 20 30 50 65 80 95 Compressed air ltr/min 9 9 10 10 10 10 Cold water ltr/min 14 14 18 18 18 18 Connections Dutch Sterilizer DS 2000 HR model 3.3.6. 4.4.6. 6.6.6. 6.6.9. 6.6.12. 6.6.16. Steam 2,5 bar ¾ Compressed air 5-8 bar ⅜ Cold water 2-6 bar ½ Drain up to 90 C mm Ø70 Electrical 230/400V 50Hz 16 A 5x2,5² (3F+0+A) PMT Partners Medische Techniek BV: 2014 23/27

Technical specifications high efficiency steam exchangers or electrical steam generators Dimensions Dutch Sterilizer DSG model 18 kw 24 kw 30 kw 36 kw 42 kw 54 kw Chamber ltr 31 31 31 64 64 64 Dimensions mm Ø300x550 Ø300x550 Ø300x550 Ø400x650 Ø400x650 Ø400x650 Weight kg 40 40 40 50 50 50 Heat loss W 750 750 800 900 900 900 Needed ventilation m³/h 160 160 160 200 200 200 Top consumption Dutch Sterilizer DSG model 18 kw 24 kw 30 kw 36 kw 42 kw 54 kw Steam kg/h - - - 50 65 80 Compressed air ltr/min 4* 4* 4* 5 5 5 Demi water ltr/min 1 1 1.5 2 2 2 Electrical kw/h 0.5 0.5 0.5 0.5 0.5 0.5 Connections Dutch Sterilizer DSG model 18 kw 24 kw 30 kw 36 kw 42 kw 54 kw Steam 4-8 bar - - - ¾ ¾ ¾ Condensate return - - - - ½ ¾ ¾ Compressed air 5-8 bar ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Demi water 2-6 bar ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Drain up to 90 C mm ø 40 ø 40 ø 40 ø 40 ø 40 ø 40 Electrical 1 230/400V 50Hz kw - - - 1 1 1 Electrical 2 230/400V 50Hz kw 18 24 30 36 42 54 1 = Steam exchanger 2 = Electrical steam generator * = in case PMT Partners Medische Techniek BV: 2014 24/27

LUPOO The internal rinsing and disinfection of hollow instruments. Available for all brands of washer disinfectors. Easy and effective! Good price Several models available Easy to use No special basket required No assembling in the instrument nets Custom made solutions possible High quality Short delivery time Dutch product CE certified With the Lupoo you can make your washer disinfector fast and easily ready to rinse and disinfect hollow instruments Some great advantages: All current instrument nets can be used for the Lupoo separators. All instruments can stay in the same net and in the same machine during the process. Connection to the water supply by the use connector with a integrated valve In case there is no Lupoo connected, there is no loss of water! Effectively of the rinsing can be shown by the use of current test methods. PMT Partners Medische Techniek BV: 2014 25/27

TOPCARE Stainless steel working tables and trolleys Working tables in several models: Available models: > LC 80 ( carts, trolleys and containers) > LC 80 PH ( pharmaceutical) > AC 8000 ( lifescience) > LC 80 BOT ( beds and OR tables) Top shelf in stainless steel or laminated. Working tables with bottom shelves or drawers All tables are available as manual or electrical height adjustable working table. Different sizes are possible and that is our great advantage, the price of custom made is similar to our standard range, so custom made for a good price! The working tables can also be equipped with: Mounts for baskets Mounts for laminate-cutters Solutions for computer (monitors), PC stations and keyboards PMT Partners Medische Techniek BV: 2014 26/27

Stainless steel drawers Internal and external RVS 304 High level of quality. Available with one, two or three drawers Fits under the working table. Stainless steel transport trolley These transport trolleys are for heavy duty and made of stainless steel. Maximum loading capacity 120kg. Also available in Flat Pack, easy for self constructing. Standard with 4 wheels two with brakes. Net weight is 20 kg. 2007.0055 Article number: Number of shelves Length x Depth x Height 2007.0055 2 84 cm x 52 cm x 93 cm 2007.0050 3 84 cm x 52 cm x 93 cm PMT Partners Medische Techniek BV: 2014 27/27