TRADE AUTOCLAVES FOR STERILIZATION
|
|
|
- Norman Simpson
- 10 years ago
- Views:
Transcription
1 TRADE R AUTOCLAVES FOR STERILIZATION
2 AUTOCLAVES STEAM STERILIZATION AUTOCLAVES RAYPA autoclaves are manufactured according to the following directives and rules: 97/23 CE.- Directive pressure equipments. CE marking. EN Safety requirements of electrical equipments of control measure and use in laboratory. Part 1: General requirements. EN Safety requirements of electrical equipments of control measure and use in laboratory. Parte Particular requirements for autoclaves that use steam for the treatment of medical use materials, and in the laboratory processes. EN Electromagnetic compatibility. Emission general rule. EN Electromagnetic compatibility. Inmunity general rule STEAM STERILIZATION The word sterilization means the total destruction of microorganisms, including the most resistance bacteria. The sterilization through saturated steam is the most usable method, applicable to all those materials that are able to bear with heat and humidity. To get a perfect balance between the sterilization temperature and the pressure of the saturated steam, the air must be evacuated efficiently from inside the autoclave's chamber. RAYPA autoclaves use to eliminate the air of the chamber, two fifferent procedures depending on the model: A) procedure of gravity displacement, where the air is movedwhen the saturated steam is applied. B) procedure of vaccum, where the air is eliminate with a vacuum pump and then the chamber is filler saturated steam until reaching the working temperature. 22
3 STERILIZATION AUTOCLAVE MINICLAVE For adjustable temperatures from 100 o C to 135 o C. Relative pressure: 0-2,2 bar. Digital regulation and reading of temperature by microprocesador. CHARACTERISTICS External case and top made in stainless steel AISI 304. Tank and lid in special aluminum alloy with the inside chamber teflon covered. Quick and safe close lid, bayonet type. Electric heating by protected element in the chamber. Temperature probe Pt100 Din class A. Safety valve. Automatic air purge, controlled by the microprocesador. Manual valve for drainage and unsteaming. Fully supplied with protecting perforated grid and wire basket in stainless steel. CAPACITY INTERIOR MEASURES EXT. MEASURES mm. POWER WHEIGHT CODE REF. LITERS Ø X HEIGHT mm. Height x Width x Depth W Kg AE x x 325 x CONTROL PANEL 1.- Microprocessor control of temperature and sterilization time. 2.- Pressure gauge reader of the internal pressure of the sterilization chamber. 3.- Main switch
4 STERILIZATION AUTOCLAVE STERICLAV-S NEW DESIGN EQUIPPED WITH MICROPROCESSOR Adjustable temperature from 105 ºC to 139 ºC. Maximum pressure: 2,5 bar. Mod. AES- 28 cod Mod. AES- 75 cod Mod. AES- 110 cod Mod. AES- 150 cod Mod. AES-12 Cod SECURITY Independent device to lock the lid of the autoclave while there is pressure inside the sterilization chamber. Safety thermostat of overtemperature. Safety valve. It discharges the pressure when it exceeds the maximum level. CHARACTERISTICS Steam sterilization autoclave, with a simple chamber. Capacity for 10 sterilization programmes. Automatic functioning. External case and top made of stainless steel AISI 304. Tank, lid and closure made of stainless steel AISI 316. Electric heating by protected elements inside the chamber. Automatic air purge, microprocessor controlled. Manual valves for draining and unsteaming. Fully supplied with protecting perforated grid to protect the heating element, and without baskets. Curled up orifice BSP 1/2 with cap, to allow the probe s introduction for the autoclave s validation or calibration (rear side accessible). Temperature sensor PT 100 Class A Temperature s control by microprocessor with P.I.D. action. Silicone gasket in the lid. 24
5 CONTROL PANEL Microprocessor with LCD screen with 2 lines of 16 characters of 8 mm, which allows to see all the information required to control the autoclave. Electrical front protection IP "START/STOP" switch. 3.- Number of programme. (10 programmes from P0 to P9). 4.- Sterilization temperature. Adjustable from 105ºC to 139ºC. 5.- Sterilization time. Adjustable between 3 and 120 minutes. 6.- "THERMOMETER" key. To select the sterilization temerature. 7.- "CLOCK" switch. To select the sterilization time. 8.- Manometer. 9.- Main switch for start up (POWER) Increase switch Decrease switch Programming access switch. MICROPROCESSOR FUNCTIONS The LCD screen indicates in all moments the process parameters. It indicates the nº of programme, temperature and time and, in second row, it gives us the informationof the phase where the sterilization cycle is at that moment. Thus, during the cycle you can see: PURGE-HEATING: air and heating purge HEATING: heating and pressure increasing STERILIZING: sterilization period when the progammed temperature is reached, and while the sterilization time lasts. COOLING: cooling phase (with natural loss of heat), which takes from the end of the sterilization time until the END OF THE PROCESS. PROCESS COMPLETED: It informs of the end of the sterilization cycle, which does not arrive until the autoclave s chamber is at 95ºC. At that moment, the lid can be opened. 25
6 PROTECTED PROGRAMMES The autoclave has 4 protected programmes. They are the most common sterilization programmes: PROGRAMME Nº TEMPERATURE TIME P0 115 O C 60 P1 121 O C 30 P2 133 O C 20 P3 121 O C 20 The programmes between P4 and P9 are free for the user to programme them according to its necessities. STERILIZATION GUARANTEE The micrprocessor checks the correct phasing of the sterilization cycle. If there is any failure in the phasing, it will appear in screen. Thus, you can see in the LCD screen the following failures: FAULT PROBE: temperature probe broken or damaged. FAULT HEATING: problems in the heating phase until the programmed temperature. FAULT TEMPERATURE: problems in the autoclave to maintain the temperature during the sterilization phase. ELECTROCUTTING: while the sterilization cycle was on, the autoclave has lost the electrical feeding. (This is not a failure properly, but the sterilization cycle is aborted. CAPACITY INTERIOR MEASURES EXT. MEASURES mm. POWER WHEIGHT CODE REF. LITERS Ø x HEIGHT mm. Height x Width x Depth W Kg AES x x 490 x AES x x 510 x AES x x 620 x AES x x 630 x AES x x 760 x AES-110 AND AES-150 MODELS, ARE ONLY SUPPLIED FOR TRIFASIC ELECTRIC CURRENT 220V OR 380 V + NEUTRAL. ACCESSORIES AND SPARE PARTS PERFORATED STAINLESS STEEL BASKETS FOR USEFUL MEASURES Nº OF BASKETS WEIGHT CODE REF. AUTOCLAVE Ø x HEIGHT mm PER AUTOCLAVE KG CI-12 AES x CI-28 AES x , CI-75 AES x CI-75 AES x , CI-150 AES x
7 NON-PERFORATED STAINLESS STEEL BASKETS Specially recommended when using the autoclave to sterilize liquids, culture medium or bags with polluted capsules. It avoids that,if the container breakes, the liquid will go to the tank of the autoclave and will obstruct the pipes. FOR USEFUL MEASURES Nº OF BASKETS WEIGHT CODE REF. AUTOCLAVE Ø x HEIGHT mm PER AUTOCLAVE KG CCI-12 AES x CCI-28 AES x , CCI-75 AES x CCI-75 AES x , CCI-150 AES x STAINLESS STEEL CYLINDERS TO STERILIZE PETRI CAPSULES AND PIPETTES. WEIGHT CODE REF. DESCRIPTION KG CEP-7040 CYL. TO STERILIZE PIPETTES Ø 70 x 400 MM CEP-1340 CYL. TO STERILIZE PIPETTES Ø 130 x 400 MM CEP-1326 CYL. TO STERILIZE PETRI CAP Ø 130 x 260 MM CEP-1347 CYL. TO STERILIZE PETRI CAP Ø 130 x 400 MM. 1 Printer of continuos sheet, it prints the programme number, the cycle number. Temperature, date, time and hour of every sterilization. Any warning notice of failure is also reflected. If at the end of the sterilization cycle everything is correct, it prints: "Sterilization O.K." This accessory must be installed in the factory Ref. IT Code It uses thermic paper roll of ø 50 mm x 57 mm. wide. HEIGHT ADJUSTABLE SUPPORT WITH SHELVES Stainless steel supports provided with three shelves. In stainless steel, adjustables in height every 12 mm. It allows to put inside the autoclave glass, objects,... of different measures to make good use of the internal space. CODE REF. FOR AUTOCLAVES SRA-1 AES SRA-2 AES SRA-3 AES SRA-4 AES-150 Fully supplied, with three shelves. 27
8 MICROPROCESSOR CONTROLLED VERTICAL AUTOCLAVES, STERILMATIC-C-DRY Adjustable temperatures from 105ºC to 139ºC. Maximum pressure: 2,5 bar. Tipe CLINOCLAV-M-DRY Tipe STERILMATIC-C-DRY SECURITY Independent device that blocks the lid of the autoclave while there is pressure in the sterilization chamber. Safety thermostat of over-temperature. Safety presostat of over-pressure. It disconnects the heating in case of exceeding pressure. Safety valve. It discharges the pressure in case of exceeding the maximum level. CHARACTERISTICS Steam sterilization autoclave with simple chamber. External case and top made of stainless steel AISI 304. Tank, lid and closure made of stainless steel AISI-316. Tank water for the autoclave feeding, with maximum and minimum level detector. Automatic water filling in the sterilization chamber. Air purge and final drying with vacuum system Curled up orifice BSP 1/2 with cap, to allow the probe s introduction for the autoclave s validation or calibration (rear side accessible). RS-232 exit to connect a printer or PC. Silicone gasket in the lid. Temperature sensor PT 100 Class A Temperature s control by microprocessor with P.I.D. action. Electric heating by protected elements inside the chamber. Supplied with perforated tray to protect the heating element, and without baskets. 28
9 TECHNICAL DESCRIPTION 1 Interface outsource RS Microprocessor. 3 Mains switch. 4 Mano-vacuometre. 5 Printer of continuos sheet (accessory installed in the factory). 6 Termic protector of the lid. 7 Condensed tank filled REAR VIEW 8 Ventilation bacteriological filter. 9 Safety valve. 10 Condensed tank empty valve. 11 Condensed tank overflow. 12 A utoclave chamber empty valve MICROPROCESSOR FUNCTIONS AND CHARACTERISTICS The autoclaves STERILMATIC- C are equipped with a microprocessor, the result of our investigation and long experience as a manufacturer of autoclaves, to fulfil the necessities and demands of our customers. The microprocessor, provided with an alpha-numeric screen of liquid-glass, shows which part of the process is doing at any time, and which failure may happen, printing the results of the sterilization, as well as the date and the hour to ensure the product sterile. It can also admit a second temperature probe to detect in the "heart" of the liquids, or in dispensable bags the real temperature, sterilizing them correctly and efficiently. In sum, it has been designed to make easy the sterilization process. 29
10 TECHNICAL DESCRIPTION Operation Mode: SOLIDS/LIQUIDS. 2 Program Number. 3 Sterilization Temperature. 4 Final Drying. 5 Sterilization Time Drying Time. 7 Sterilization Temperature Select Sterilizing and Drying Time Select. 9 Increase Key. 10 Decrease Key. 11 Programming Set Start/Stop of selected cycle Parameters that can be programmed: Sterilization temperature Sterilization time Drying or not-drying Drying time Sterilization mode: SOLIDS/LIQUIDS Parameters printing Programming variables: Number of programmes: 10 Sterilization temperature: from 105ºC to 139ºC Sterilization time: from 3 to 120 minutes Solids/Liquids Drying/Not-Drying Drying time: from 1 to 60 minutes When we execute a sterilization program with the microprocessor, its screen is showing us at the very moment in which cycle of the process is, apart from giving us the information about the temperature and time of sterilization and drying. A complete program of sterilization is composed by the following phases: VACUUM: Initial vacuum (air ejection of the chamber). P (bar) Vacuum Heating Esterilizing Unloading Drying End of process FILLING: HEATING: Automatic water distilled filled of the sterilization chamber. Heating and pressure increase. STERILIZING: Sterilization. UNLOADING: Automatic unload of the water and steam of the sterilization chamber, to the water distilled tank. DRYING: Vacuum and barometric leveling. T END OF PROCESS: End of sterilization cycle notice. 0 In the LIQUID programmes, the UNLOADING phase is not executed and, instead of it, there is the COOLING phase (cooling by natural loss of heat until the End of the Process temperature). Also in the -1 LIQUID programmes, the DRYING phase does not exist because it is not possible to program a final drying. The microprocessor display will display a warning messages when, for example, the condensers tank does not have enough water, when the bacteriological filter must be changed, or when the results are being printed. In this way, if any anomaly appears during the execution of the program, the program is aborted and a failure message will appear, for example for the breaking of the temperature sensor, if there is failure during the filling of the the autoclave s chamber period, if there is failure in the heating period, if the sterilization temperature defers 2 degrees above or below from the selected temperature, if there has been any electrical cutting,... All these messages in display help favourably to understand if there is any anomaly. 30
11 CAPACITY INTERIOR MEASURES EXT. MEASURES mm. POWER WHEIGHT CODE REF. LITERS Ø x HEIGHT mm. Height x Width x Depth W Kg AE-28-DRY x x 510 x AE-75-DRY x x 620 x AE-110-DRY x x 630 x AE-150-DRY x x 760 x Fully supplied with perforated tray heating element protector and without baskets. AE-110-dry and AE-150-dry models, are only supplied for tree-phase electric current 220v v + neutral FLEXIBLE HEART PROBE PT-100 Cod Recommended for the sterilization of culture mediums in flasks of 1 litre or more, because this device starts up the sterilization time when the medium reaches the adequate temperature. At the same time it can be placed in the middle of the residuum bags to ensure the sterilization at the proper temperature in the inside of the bag. The temperature control through the second probe (installed as an accessory) is armed or disarmed by means of the microprocessor screen. This accessory must be installed in the factory. Ref. PT-2 Code TABLE TOP PRINTER OF CONTINUOS SHEET It prints the programme number, cycle number, temperature, time date and hour of every sterilization. Every warning or failure message is also reflected. If at the end of the sterilization cycle everything is correct, it prints STERILIZATION O.K.. This accessory must be installed in the factory (Panel Printer). Ref. IT Code It uses thermic paper roll of ø 50 mm x 57 mm. wide. TABLE TOP PRINTER OF CONTINUOS SHEET It prints the programme number, cycle number, temperature, time, date and hour of every sterilization. Every warning or failure message is also reflected. If at the end of the sterilization cycle everything is correct, it prints STERILIZATION O.K.. Electrical feeding 230V. Connection serial RS-232. Ref. ITS Code It uses standard paper roll of ø 50 x 57 mm wide. 31
12 PERFORATED STAINLESS STEEL BASKETS FOR USEFUL MEASURES Nº OF BASKETS WEIGHT CODE REF. AUTOCLAVE Ø x HEIGHT mm PER AUTOCLAVE KG CI-28 AES x ,5 CI-75 AES x ,5 CI-75 AES x CI-150 AES x NON-PERFORATED STAINLESS STEEL BASKETS Specially recommended when using the autoclave to sterilize liquids, culture medium or bags with polluted capsules. It avoids that,if the container breakes, the liquid will go to the tank of the autoclave and will obstruct the pipes. FOR USEFUL MEASURES Nº OF BASKETS WEIGHT CODE REF. AUTOCLAVE Ø x HEIGHT mm PER AUTOCLAVE KG CCI-28 AES x ,5 CCI-75 AES x ,5 CCI-75 AES x CCI-150 AES x STAINLESS STEEL CYLINDERS TO STERILIZE PETRI CAPSULES AND PIPETTES. WEIGHT CODE REF. DESCRIPTION KG CEP-7040 CYL. TO STERILIZE PIPETTES Ø 70 x 400 MM CEP-1340 CYL. TO STERILIZE PIPETTES Ø 130 x 400 MM CEP-1326 CYL. TO STERILIZE PETRI CAP Ø 130 x 260 MM CEP-1347 CYL. TO STERILIZE PETRI CAP Ø 130 x 400 MM. 1 HEIGHT ADJUSTABLE SUPPORT WITH SHELVES Stainless steel supports provided with three shelves. In stainless steel, adjustables in height every 12 mm. It allows to put inside the autoclave glass, objects,... of different measures to make good use of the internal space. Fully supplied, with three shelves. CODE REF. FOR AUTOCLAVES SRA-1 AE SRA-2 AE SRA-3 AE SRA-4 AE
13 STERILIZATION AUTOCLAVES WITH MICRPROCESSOR CLINOCLAV STEAM STERILISATION AUTOCLAVES Class N according to EN Adjustable temperatures up to 135 o C. (2,5 bar). Class N autoclaves are indicated to sterilize unwrapped solid material to be used just after being sterilized, or where there is no priority to keep it sterilized CHARACTERISTICS Epoxy resin oven painted external case. Front part made in stainless steel AISI 304. Sterilization chamber and lid made in stainless steel AISI 316. Electrical heating with immersion heater inside the chamber. Automatic air purge. Time and temperature regulation microprocessor with digital screen. Controller resolution 1 o C. Temperature probe Pt 100 DIN class A. Manual filling of the sterilization water. Condensed tank. 33
14 SAFETY - SAFETY VALVE unloads the internal pressure in case of overpressure. - SAFETY THERMOSTAT disconnects and blocks the heater of the autoclave in case of overtemperature or lack of water in the sterilization chamber. - OPEN LID SENSOR blocks the start of the sterilization cycle if the lid is open or not properly closed. CONTROL PANEL 1.- Temperature and sterilization time controlled by microprocessor Open door alarm pilot-light. 3.- SOLID/LIQUIDS sterilization selector. 4.- Main switch. 5.- Manual filling valve of the sterilization water Pressure gauge. 7.- Overtemperature alarm pilot-light CAPACITY INTERIOR MEASURES EXT. MEASURES mm. POWER WHEIGHT CODE REF. LITERS Ø x HEIGHT mm. Height x Width x Depth W Kg AH-11N x x 510 x AH-21N x x 590 x FULLY SUPPLIED WITHTHE FOLLOWING ACCESSORIES 1 Trays support. 2 Perforated trays in stainless steel (Autoclave AH-11 N). 3 Perforated trays in stainless stee (Autoclave AH-11 N). 1 trays holding clamps. 1 Flexible hose with connector for emptying the condensating tank. 34
15 STERILIZATION AUTOCLAVES WITH MICRPROCESSOR CLINOCLAV STEAM STERILISATION AUTOCLAVES Class S according to norm EN Autoclaves of class S, they are autoclaves indicated to sterilize solid material without Pocketing, solid pocketed material, small porous elements, and hollow elements of type B (slightly deep and broad cavities). CONSTRUCTION Sterilisation chamber made of stainless steel AISI 316 polished and bright Exterior case in stainless steel, lid and control panel support oven painted SAFETY SYSTEMS Safety device that blocks the program if the door is not correctly closed. The same device aborts the sterilisation cycle and removes the autoclave s pressure automatically, when trying to open the door while the sterilisation cycle is on. SAFETY VALVE, removes the inner pressure in case of going over the levels SAFETY THERMOSTAT, disconnects the autoclave s heating in case of overtemperature. WORKING CYCLES The autoclave CLINOCLAV-M is equipped with 5 sterilisation programmes for a fast and perfect treatment of the different materials, making the user s work easy. 35
16 CONTROL PANEL 1.- LCD SCREEN It informs about the sterilisation process and about the different sequences or malfunctions of the named process. 2.- QUICK STERILISATION Temperature: 134 C. Time: 3 min. WITHOUT DRYING INDICATED FOR: Turbines, counter-angles, hand-pieces, glass and non-packed instruments 3.- STERILISATION IN GENERAL Temperature: 134 C. Time: 15 min. Drying: 12 min. INDICATED FOR: Pourous materials (gauzes, fabrics...) Bagged instrumental, instrumental in general 4.- DELICATE INSTRUMENTAL Temperature: 121 C. Time: 30 min. Drying: 12 min. INDICATED FOR: Manufactured materials in plastic, wired and conductions, ultrasonic hand-pieces, electroscalpels, OPTIONAL FLASH Program adjustable to the demmands of the user for the sterilisation. It allows the introduction of temperature and time at your own choice, so the CLINOCLAV-M will adapt to the requirements that in the future will be compulsory by law. 6.- DISINFECTION Temperature: 105 C. Time: 30 min. Drying: 12 min. INDICATED FOR: Packed or unpacked material (optic fiber, polymeration lamp-heads,...) 7.- PRINTER KEY ON/OFF Key to print the data of the last cycle. 8.- START/STOP KEY Key to start or to stop the sterilisation program programmed. 9.- PRESSURE AND VACUUM GAUGE It indicates the vacuum or pressure of the sterilisation chamber MAIN SWITCH Connects or disconnects all the circuits of the autoclave. 36
17 PREVACUUM SYSTEM The autoclave CLINOCLAV-M is equipped with a device that makes the vacuum in the chamber before the start of the sterilisation process. That makes it possible to achieve a steam saturation inside the chamber for the correct sterilisation. At the same time, once the cycle has finished, there is a vacuum inside the chamber that optimises the drying process. Due to the vacuum system, the autoclave CLINOCLAV-M is equipped with a bacteriological filter for the air entrance (pourosity 0,2 micras). PARTICULAR FUNCTIONS The autoclave CLINOCLAV-M has got level sensors of automatic functioning level, which dosify the necessary water for the sterilisation, or warn if the condensated tank must be refilled, or empties the dirty water tank. The autoclave CLINOCLAV-M always uses clean water for the sterilisation DETAIL OF THE BACTEREOLOGICAL FILTER AND DEVICES FOR THE TO DRAIN OF THE DIRTY AND CLEAN WATER TANKS Auto-diagnostical system, which supervises that the sterilisation is done in all its phases. If it doesn t, the anomaly is shown in the display and it aborts the sterilisation cycle. Rear connection for the printer RS-232. MODELS CAPACITY INTERIOR MEASURES EXT. MEASURES mm. POWER WHEIGHT CODE REF. LITERS Ø x HEIGHT mm. Height x Width x Depth W Kg AH-11S x x 510 x AH-21S x x 590 x STANDARD ACCESSORIES The autoclave CLINOCLAV-M is supplied with the following accessories: 1 Tray support 2 St. St. Perfrated trays (autoclave AH-11) 3 St. St. Perfrated trays (autoclave AH-21) 1 Bags support 1 Pincers to extract trays 1 Flexible tube with connector to empty the tanks 37
18 STERILIZATION AUTOCLAVES WITH MICRPROCESSOR CLINOCLAV B PLUS STEAM STERILISATION AUTOCLAVES Class B according to EN Fractionated vaccum Steam generator incorporated Class B autoclaves are indicated to sterilize solid materials, hollow and porous wrapped or unwrapped. CLINOCLAV B PLUS, autoclave is equipped with a powerful vacuum pump and different programmes to effectuate alternatively several vacuums and raises of pressure in a successive way in the sterilization chamber, before the proper sterilization phase. Thus, the air in the wrapped material and in the pourous and hollow elements is completely removed, and thus the saturated steam can penetrate to the heart the items. 38
19 STERILIZATION CYCLE DIAGRAM Pressure (bar) 2.00 Esterilization Timer (min) Fraccionated vacuum Drying CHARACTERISTICS CONTROL BY MICROPROCESSOR All the parameters, temperature, pressure and time are effectively evaluated by an electronic control system with microprocessor. Any anomaly in the system aborts automatically the sterilization cycle. A wide LCD display shows all the time all the necessary parameters and messages easily and clearly. - PRE-HEATING STAND BY An automatic system keeps the sterilization chamber pre-heated before the sterilization cycle. Thue the cycle is accelerated and condensations avoided. - STEAM GENERATOR INCORPORATED With this system the stablished parameters of pressure and temperature are reached fast and efficiently. 39
20 AUTOMATED DOOR LOCKING An automated system locks automatically the door of the autoclave at the beginning of the sterilization cycle, and it keeps it locked until the cycle is finished and the pressure is 0. DOOR LOCKING A triple dynamic electromechanical safety system assures the locking of the door until internal presure is 0. - FRACTIONATED VACUUM - A fractionated vacuum system in the phase before the sterilization, like in the drying, assure a perfect penetration of the steam and an efficient drying. - INTEGRATED VESSELS OF LOAD AND UNLOAD - Two integrated vessels in the autoclave, one for the pure water and the other one for the used waret, guarantee a clean sterilization. - It is possible to effectuate the load of the vessel of pure water automatically from an external vessel, as well as unload of the used water also to an external vessel or draining. - AUTOMATIC TEST CYCLES - CLINOCLAV B PLUS a part from the sterilization cycles, is also equipped with three test cycles to control the autoclave. - Test to control de vacuum VACUUM TEST, assures a perfect airtightness of the sterilization chamber and the hydraulic circuit. - Test to control the capacity of the autoclave to steriliza pourous and/or wrapped objets BOWI & DICK TEST. - Test to control the capacity of the autoclave to sterilize hollow objets type A HELIX TEST. 40
21 STAINLESS STEEL CHAMBER Sterilization chamber made of stainless steel AISI 316 and polished electrilically. Its wide capacity of 21 litres. Allons an special support with five trays, and it facilitates and improves the sterilization. INTEGRATED PRINTER CLINOCLAV B PLUS has an integrated printer from factory. It allows registering completely the sterilization cycle. At the same time, the printers is basic to validate the vacuum test. TECHNICAL CHARACTERISTICS Apparatus: Sterilization autoclave type B according to EN Total volume: 21 litres Sterilization chamber measures: Ø 250 mm x 430 mm depth External measures: 630mm height x 430 mm width x 600mm depth Feeding power: 220v ± 10% Net frequency: 50/60 Hz. Nominal power: 2200w Sterilization programs: 11 fix programmes (porous, prion, Stiff hollows,solids, Emergencies and disinfection), 3 Modifiable programs for the user Total mass to sterilize: Pourous material 1.3Kg. Non-Wrapped solid and/or hollow material 6.3 Kg Wrapped solid and/or hollow material 3.8 Kg STANDARD EQUIPEMENT It is provided with the following items: 1 holder for trays in stainless steel 5 trays for the instruments made of stainless steel wire. 1 extractor of trays 1 destillated water container for manual use 1 Silicone Tube two meters long to empty the water 1 Instruction for use MODEL: AH-21 B PLUS CODE:
AUTOCLAVE STEAM STERILIZERS
AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option
Sterilizers with extra class
Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-class (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave
Table Top STE-TEN, 1 Liter utoclave STE-TEN It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line
Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
Laboratory Line. Vertical and Bench-Top Life Science Autoclaves
Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
MELA quick 12+ Compact. Fast. Strong.
MELA quick 12+ Compact. Fast. Strong. The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for semicritical use (restorative treatment)
The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series
The Power of Innovation. For better Sterilization. Autoclaves: Systec V-Series t h e a u t o c l a v e c o m p a n y Systec V-Series: Vertical autoclaves. These autoclaves don't just seem to be different;
Steam Sterilization Cycles for Lab Applications
Steam Sterilization Cycles for Lab Applications Presented by Gary Butler STERIS Life Sciences August 2009 Early Steam Sterilizers Koch Upright Sterilizer First Pressurized Sterilizer First built by Pasteur-Chamberlain
Tabletop Line. Automatic and Semi-Automatic Autoclave Series
Tabletop Line Automatic and Semi-Automatic Autoclave Series Tuttnauer Your Sterilization & Infection Control Partner Company Profile For over 80 years, Tuttnauer s sterilization and infection control products
STERILIZATION AND BACTERIOLOGICAL OVENS - FURNACES
STERILIZATION AND BACTERIOLOGICAL OVENS - FURNACES Poupinel sterilizers page 137 Drying and sterilization ovens pages 138 to 150 Universal precision ovens pages 143 to 144 High temperature ovens page 147
Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient
Microbiological Incubators Safe, easy and efficient Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new laboratory microbiological incubators is designed with
Manual 20.2.2015 v1 Page 1 of 17. Manual. Laboratory autoclave
Manual 20.2.2015 v1 Page 1 of 17 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav
FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS
The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION Applications THE WIDE RANGE OF USING CERTOCLAV AUTOCLAVES MICROBIOLOGY / BIO-CHEMISTRY Autoclave culture mediums Refuse sterilisation Efficiently
The Power of Innovation. For better Sterilization. Pass-through autoclaves: Systec D-Series 2D Horizontal front loading bench-top autoclaves: Systec
The Power of Innovation. For better Sterilization. Pass-through autoclaves: Systec D-Series 2D Horizontal front loading bench-top autoclaves: Systec D-Series t h e a u t o c l a v e c o m p a n y Systec
STERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
Climate chamber with illumination
KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC PROFILE HMC Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges, that are tailor-made
Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization
Cliniklav 25 For highest quality in surgical applications MELAG Evidence Based Sterilization Cliniklav 25 The big one from MELAG a powerful piece of technology Built-in printer for documenting program
Large Steam Sterilizers for the Life Sciences. Laboratory Line
Large Steam Sterilizers for the Life Sciences Laboratory Line Large Steam Sterilizers for the Life Sciences Sterilization in a laboratory environment has its unique requirements. The types of loads that
Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.
Fotolia Layout Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves. Performance and competence. Experience counts We focus on
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers
Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers Laboratory incubators (CL) and drying ovens (SL)
Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves
Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste
Laboratory Autoclave SN210/310/510,SQ510/810
1/5 Laboratory Autoclave SN210/310/510,SQ510/810 SN210/310/510,SQ510/810 The highest temperature of 135deg.C Upwards opening lid SN210 SN310 SN510 Effective Capacity : 20LEffective Capacity : 32L Effective
Our convenient autoclave, right on the laboratory bench.«
» Our convenient autoclave, right on the laboratory bench.«sterilisation Materials testing Media preparation www.certoclav.com Ready to go with 3 easy steps Fill Large usable volume by means of a vertical
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
WATERBATHS AND OILBATHS
WATERBATHS AND OILBATHS New bath generation, still more accurate through innovative control technology Combined start delay and hold time; on Excellent models setpoint-dependent More security through at
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2
0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
Hospital Sterilizers. T-Max Line
Hospital Sterilizers T-Max Line Hospital Sterilizers Sterilization is a complex process. Like any complex process, many things can go wrong. A Hospital depends on its CSSD: Central Sterile Services Department.
The Premium-Plus-Class Now even better
The Premium-Plus-Class Now even better Innovation and quality the philosophy of a family-run business As an owner-run and operated family concern founded in 1951, we have a long history of successful specialization
Systec Laboratory Autoclaves
Laboratory Autoclaves Systec V-Series. Vertical floor-standing autoclaves. Systec D-Series. Horizontal bench-top autoclaves. Performance and competence. Experience counts We focus on only one thing: laboratory
Why do our customers make their choice for PMT Partners Medische Techniek BV?
Why do our customers make their choice for PMT Partners Medische Techniek BV? Company presentation 2014 CONTENT Description Page Introduction... 3 Why the choice for PMT Partners Medische Techniek BV?...
Clinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
Horizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:
STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
Medical Waste Autoclaves. Medical Waste Autoclaves
Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,
Product-friendly and fast...
Product-friendly and fast......vacuum Heating and Drying Ovens V V T Optimum drying results under exceptional conditions Drying in a vacuum... The Advantages No doubt, there are various ways of drying
Laboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line
Partnership Large Steam Autoclaves for the Life Sciences Laboratory Line Large Steam Autoclaves for the Life Sciences Sterilization in a laboratory environment has its unique requirements. Tuttnauer laboratory
Thermostatic Equipment
Thermostatic Equipment comming soon (06/2015): Climatic Chambers with LED lighting Climatic Chambers with steam humidifier Peltier - Cooled Incubators Refrigerators with back - up system ultra - Low Freezers
40 Vacuum drying ovens
40 Vacuum drying ovens Vacuum drying ovens 41 VD VDL Absolutely reliable drying. Drying with no residues, no danger of incrustation, no oxidation all under gentle cycle conditions. We have also developed
Specifications. Amaro 5000 & Steri 21 MD009/04 EN. A. J. COSTA (IRMÃOS), LDA. Desde 1953 ao Serviço Médico-Hospitalar
Specifications Amaro 5000 & Steri 21 1 1. GENERAL INFORMATION 1.1. Technical Introduction A. J. Costa (Irmãos), Lda. steam sterilizers are designed to cover a large field of applications for hospitals
Thermo Scientific Heratherm Microbiological Incubators. Safe,
Thermo Scientific Heratherm Microbiological Incubators Safe, easy and efficient Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Convection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
The power of innovation. For better media preparation. Media preparators Systec MediaPrep.
The power of innovation. For better media preparation. Media preparators Systec MediaPrep. t h e a u t o c l a v e c o m p a n y Prepare and sterilize microbiological media. Fast, accurate and easy to
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Condensate water pump with neutralisation system
Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION
MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION Autoclave SERENA/Manual for technician/rev.02/23.05.14 Pagina 1 SUMMARY 1. ACCESS
DIESEL FUEL CONDITIONING
COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.
Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the
Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos
April 2015 Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos 3M Deutschand GmbH, IPD, Decontamination University
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Medical Market Laboratory EMEA
Medical Market Laboratory EMEA Space for 3M Montage Penetration tests in according to the ISO 11140 Josephus P.C.M van Doornmalen Gomez Hoyos Croatia, March 27, 2009 Outline Purpose penetration tests Original
Touchclave-Lab... the revolutionary new range of square-section laboratory sterilizers from LTE Scientific
Other Products and Services from LTE Scientific LTE Scientific Ltd. LTE Cylindrical Chamber Autoclaves 40 to 380 litres capacity LTE Touchclave Systems Autoclaves from 150 to 10,000 litres capacity Kill
PORTABLE LABORATORY MODEL AVAILABLE!
S E L E C T I O N G U I D E LARGEST TABLETOP STERILIZER AVAILABLE! EASY TO PROGRAM TABLETOP STERILIZERS! QUICK PURE WATER FOR YOUR STEAM STERILIZER! FAST INDICATION AND EASY TO USE! HARVEY STERILIZERS
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Questionnaire Pure Media Systems
1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold
automatic back-flush program non-spattering hot water delivery large boiler with one heat-exchanger per group, thermo-syphon system
Mirage Bastone automatic back-flush program non-spattering hot water delivery large boiler with one heat-exchanger per group, thermo-syphon system extra long lower tubes for cool running enlarged cavity
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Guidance on safe use of Autoclaves
Safety Office Reviewed: Dec 2013 Reviewed: DD Month Year Guidance on safe use of Autoclaves 1. Hazards & Uses There are several different types of hazard associated with the use of autoclaves. The main
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical
Vakulab PL All-rounder for laboratory and research Long life time and short cycle times Space saving and ergonomical Model diversity and tailored to specific application MMM. Protecting human health. Vakulab
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL
DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL BRAZILIAN INDUSTRY NATIONAL PRODUCT Web Table of content: 1- Product description 2- Technical specifications of the product 3- Product parts 4-
Refrigerators - Freezers. Ekofrigolab & Ekobasic Series
Refrigerators - Freezers Ekofrigolab & Ekobasic Series Angelantoni Life Science S.r.l. manufactures a wide range of refrigerated cabinets and combined refrigerator/freezer cabinets. We offer high reliability
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 150 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 150. Code: Description:
Steripro cgmp. Steam Sterilizers
Steripro cgmp Steam Sterilizers Steripro cgmp Steam Sterilizers BMT worldwide QUALITY, RELIABILITY, INNOVATIO N BMT USA is a member of the MMM Group, one of the world s leading suppliers of sterilization
Condensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal