ISOMAG Millennium ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION



Similar documents
ISOMAG Millennium UC 250 VERSIONE A PARETE UC 250 WALL VERSION UC 250 A QUADRO UC 250 PANEL MOUNTING VERSI ON

THERMAL ENERGY METER MC 108/ET

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

Serie ET / ET Series

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

B12 INTERRUTTORI DI PROSSIMITA INDUTTIVI PUSH-PULL STANDARD SERIE SERIES INDUCTIVE PROXIMITY SWITCHES PUSH-PULL STANDARD B12

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Electronic Pressure Switch EDS 3000

Multifunction devices

How To Use A Flowmeter

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

ISOIL ML110 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS

Energy Management Power Analyzer Type WM14-96 Basic Version

Relative and absolute pressure switch type 529

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Series DFMT Digital Paddlewheel Flowmeter

Sensori induttivi conformi alle norme DIN CENELEC EN EN NAMUR (3) CARATTERISTICHE FEATURES. 2mm 3 24 Vdc 10%

Short information Parameters are programmed via front-side membrane keypad

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

IFC 070 Technical Datasheet

serie FX3 e FX4 - FX3 and FX4 series

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Anelli Rings (1) (1) (2) (2) (3) TIPI - TYPES CARATTERISTICHE FEATURES. 1mm 3 24Vdc 10 30Vdc 10 30Vdc 10% 10% 200 ma.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Electronic Pressure Switch EDS 300

SITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG Manual *083R9141* Order no.

Technical Data. back-up time in minutes 100% load % load

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Digital inductive conductivity transmitter

DS 600. A contact free flux gate based current measurement sensor 600A rms

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

photoelectric highlights

Telephone- and leased line modem for industrial applications TD-36

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

c-pro nano RACK & c-pro micro RACK

DESCRIPTION DESCRIZIONE

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Alimentatori LED LED drivers

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Preset Counter signo 721

Electric Rotary Actuator - On/Off or programmable control actuator

The multi-functional integrator Supercal 531

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

020-inox 025-inox 040-inox 050-inox 070-inox 080-inox Elettropompe autoadescanti / Self-priming electric pumps

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

PRESSACAVI CABLE GLANDS

QSLM Dual inlet decompression unit with automatic change-over system FEATURES

I STAR COMPUTER CO., LTD

Plastic tube flowmeters Series PT/PS

Quick Connect. quick - simple - efficient.

BLACKLIGHT RADIANT HEATER BLACKLIGHT TECNOLOGIA RADIANTE

is then retained absolutely without interruption.

API Marine. BMS Presentation. Ballast Measurement Systems

Inductive sensor NI10-M18-Y1X-H1141

INTERRUTTORI DI PROSSIMITA INDUTTIVI IN MINIATURA INDUCTIVE PROXIMITY SWITCHES MINIATURE SERIES

Rack mounted telephone- and leased line modem for industrial applications

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

SERIE FX3 e FX4 - FX3 and FX4 SERIES

M-Bus-Logger Data Logger

TERMINAL TACTIL A COLOR CON PLC INTEGRADO Pag 2. TERMINAL TACTIL MONOCROMO CON PLC INTEGRADO Pag 4. PANEL OPERADOR CON PLC INTEGRADO Pag 9

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Prevent A Forklift From Tipping

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

Duct Humidity Transmitter

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

AMTRON E-30 Compact heat and cooling meter

80 Series - Modular timers 16 A. Features

4 Posiflow Proportional Solenoid Valves

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

IP66. Apparecchio a incasso calpestabile per interni ed esterni. Walk over recessed fixture for indoor and outdoor applications

3 3RG78 45 program overview

Incubator with mechanical convection

3-phase, bidirectional energy meter

Inductive Proximity Sensors

Series 7500 Torque Sensor

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Features. Picture. Specifications

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

Series 6000 Torque measured metal bellow coupling

Manual K 100 PR K 100 W PR. Measuring and control instruments for ph and ORP measurements ph 25.0 C S1 S2 Auto ph 25.

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

4 IN 5 OUT MATRIX SWITCHER YUV & Stereo Audio

RAINCONTROL LCD Special

HYDRUS ULTRASONIC METER

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Transcription:

M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 3 F 1 CONVERTITORE AD ALTA FREQUENZA DI CAMPIONAMENTO (FINO A 400 MISURE/SECONDO) PER MISURATORI ELETTROMAGNETICI SERIE MILLENNIUM FAST SAMPLING FREQUENCY CONVERTER(UP TO 400 SAMPLES/SECOND) FOR ELECTROMAGNETIC FLOWMETER MILLENNIUM SERIE S ML3F1 ESECUZIONE COMPATTA ML3F1 COMPACT EXECUTION

SPECIFICA TECNICA Data Documento 20/02/04 Pagine 2/6 DATI TECNICI / TECHNICAL DATA Materiale Custodia Material Box Dimensioni / Dimension 75 X 140 X 60 mm Classe Di Protezione Protection Rate IP 67 Pressacavi / Cable Gland N 2 PG 11 Temp Amb / Amb. Temperature Uscita Impulsi Frequenza Pulse / Frequency Output Uscita In Corrente Current Output Ingresso Digitale / Digital Input Acciaio inox AISI 304 / Stainless steel AISI 304-20 +60 C 1250 Hz (standard), 12,5 KHz ( OPTIONAL ), 100mA, 40 Vdc ( OPTIONAL ) 4 20mA RL 800W PASSIVA / passive Funzione programmabile / programmable function Uscite ON-OFF / ON-OFF Outputs 1 o.c. + 1 OPT. (prog. imp./freq./all. ) / (programmable function) Misura Bidirezionale Bi-Directional Valore Di F.S. / FS Value Interfaccia Di Comunicazione Communication Interface Funzione Di Autodiagnosi Diagnostic Funct. Rilevazione Tubo Vuoto Empty Pipe Detect. Separazione Galvanica Galvanic Isolation Memorizzazione Dati Data Storage Presa Programmazione Programming Plug In Funzione Dosaggio Bacth Function Certificazione CE CE Certification Incertezza Della Misura Measurement Tolerance Sì / Yes 0,4 10m/s RS 485 (RS232 Opz. / Opt. ) / Profibus DP ( Opt. ) Sì / Yes Sì / Yes Tutti gli ingressi e le uscite sono separati tra loro e dall alimentazione All the inputs / outputs are galvanically isolated from power supply In mancanza di alimentazione i dati vengono memorizzati in una E-Eprom Eeprom stored measuring values on power failure Presa protetta per collegamento PC o terminale portatile Protected plug in for connection to PC or hand terminal Sì, anche con preset automatico (auto-apprendimento ) Yes, also with auto-preset Strumento certificato CE / Instrument with CE certificate Portata ( volume) = ±0,05% v.l. / Flow rate (volume) = ±0,05% v.l. Out 4/20 ma = ± 0,08 % v.l. Out Frequenza = ± 0,08% v.l. / Frequency Out = ± 0,08% v.l. Ripetibilità / Ripetibility Migliore dello 0,01% / Better than 0,01% Alimentazione / Power Supply 10 33 VDC

SPECIFICA TECNICA Data Documento 20/02/04 Pagine 3/6 DIMENSIONI DI INGOMBRO / OVERALL DIMENSIONS 168 145 62 117 141 79

SPECIFICA TECNICA Data Documento 20/02/04 Pagine 4/6 CONNESSIONI ELETTRICHE / ELECTRICAL CONNECTIONS (SOLO CON MODULI DI ESPANSIONE ONLY WITH EXPANSION MODULE) OUT ON/OFF " + "(collector) OUT ON/OFF " - " (emitter) - INPUT ON/OFF + INPUT ON/OFF + - POWER SUPPLY 1 2 3 4 5 6 7 8 9 10 11 1213 IF02 MT 200 STANDARD DIGITAL OUT STANDARD DIGITAL INPUT 7 (+) 10 K 10 (+) 5/33 Vdc (ON) 0/1,5 Vdc (OFF) 8 (-) 9 (-) DIGITAL OUTPUT ( EXPANSION MODULE ) DIGITAL INPUT ( EXPANSION MODULE ) 5 (+) 2K2 3 (+) 2 2K2 6 (-) 1 4 (-)

SPECIFICA TECNICA Data Documento 20/02/04 Pagine 5/6 FUNZIONI DISPONIBILI / AVAILABLE FUNCTIONS 1.SENSOR1.1 ND 1.2 KA 1.3 KL + / - 1.4 E.P.DETECT 1.5 AUTOZ. CAL. 1.6 E.P. CALIBR. SET ND SET KA SET KL ON/OFF 2.SCALE 2.1 FS1 2.2 FS2 2.3 MU.TOT 2.4 IMP 2.5 TPUL 2.6 FRQ 2.7 SW SET FULL SCALE 1 SET FULL SCALE 2 MEASURE UNIT PULSE VALUE DURATION PULSE FULL SCALE FREQ. SPEC. GRAVITY VOLUME UNIT VOLUME UNIT TYPE OF UNIT MISURE UNIT TYPE OF UNIT TYPE OF UNIT DECIMAL TOTALIZER TYPE OF UNIT TIME UNIT MEASURE TIME UNIT MEASURE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE 3.MEAS. 3.1 T. CONST 3.2 SKIP THR 3.3 PEAK THR 3.4 CUT-OFF 3.5 START THR 3.6 AC LINE FIL 3.7 AUTOCAL. TIME CONTANT SET ACC. THRESHOLD PICK CUT THRES. LOW FLOW ZERO TIMING THRES. POWER SUP. FIL. AUTOCALIB 4.ALARM 4.1 MAX THR 4.2 MIN THR 4.3 HYST 4.4 E.P. THR 4.5 ma VAL.FAULT 4.6 Hz VAL.FAULT MAX FLOW ALARM MIN FLOW ALARM HYSTERESIS TH. E. P. THRESHOLD 4/20 ma ALARM SET FREQUENCY ALARM 5.INPUT 5.1 T1 RESET 5.2 T2 RESET 5.3 COUNT LOCK 5.4 CALIBRATION 5.5 RANGE CHANGE 5.6 BATCH 5.7 INPUT 2 EN. RESET OF TOT.1 EN. RESET OF TOT.2 LOCK TOTALISER AUTOZERO CAL. EXT. RANGE CHANGE EXT BATCH ST./STOP EXT FUNCTION INPUT 2 FUNCTION ACTIVE WITH INPUT IN VOLTAGE FUNCTION ACTIVE WITH INPUT IN VOLTAGE 6.OUTPUT 6.1 OUT.1 6.2 OUT.2 (OPT.) 6.3 DUTY CYCLE 6.4 OUT.MA1 SEE THE TAB REFER TO THE FUNCTIONS FOR OUTPUTS : MENU 6 "OUTPUT" 7. COMM. 7.1 ADDRESS 7.2 SPEED NETWORK ADDRESS RS485 SPEED 8. DISPLAY 8.1 LANGUAGE 8.2 TOTALIZ. 8.3 DISP. FR. TOT. DISPLAY MODE REFRESH DISPLAY 9.BATCH 9.1 N. SAMPLES 9.2 DIFF.THR 9.3 V.COM 9.4 V. PRE 9.5 AUTO BATCH 9.6 BM AUTO SEL 9.7 CONS. MODE SAMPLES V. COMP. %LIMIT.COMP.VAL. COMP. VAL. PRE-BATCH VALUE AUTO BATCH FORMULA AUTO-SEL. CONS. ST. BATCH 10.DIAGN. 10.1 CALIBRATION 10.2 SELFTEST 10.3 SIMULATION ENABLE CALIB. METER AUTOTEST FLOW SIMULATION 11.INT.DAT 11.1 L2 KEYCODE 11.2 LOAD FACT. 11.3 LOAD USER 11.4SAVE AS USER LEVEL 2 CODE FACTORY RECALL USER RECALL USER VALUE SAVE 3.8 ATORANGE AUTO SCALE 3.9 E. SAVING ENER. SAVING

SPECIFICA TECNICA Data Documento 20/02/04 Pagine 6/6 COME ORDINARE / HOW ORDER SENSORE / SENSOR ML 3F1 Display A Versione cieca (senza display e senza tastiera di programmazione) / Blind execution (without display and programming keys) Materiale custodia convertitore - Classe di protezione / Housing material - Protection rate 1 Custodia in Acc.Inox AISI304, classe di protezione IP67 / AISI304 Stainless Steel housing, protection rate IP67 Versione / Version A Versione compatta, con sensore MS... (massima temperatura del liquido 130 C) / Compact version with sensor MS... (liquid maximum temperature 130 C) B Versione separata, accessori in Aisi 304, max distanza 1 m / Separate version with Aisi 304 accessories, max distance 1 m Moduli aggiuntivi / Additional module 0 senza moduli aggiuntivi / Without additional module 1 ME31 :2 out on/off alta frequenza ( 12500 Hz ) + n 1 inp. On/off / ME 31 : 2 out on/off high frequency ( 12.500 Hz ) 2 ME32 : out 4/20 / ME 32 : out 4/20 3 modulo di comunicazione : Profibus PA/ in preparazione / Profibus PA module /under preparation 4 ME 34 modulo di comunicazione : Profibus DP / ME 32 : Profibus DP module 5 ME 33 : modulo di comunicazione : RS 485 / ME 33 : RS 485 communication module ML 3F1 A 1 A 0 ATTENZIONE/WARNING I DATI POSSONO CAMBIARE SENZA ALCUN PREAVVISO/THE ABOVE DATA CAN BE CHANGED WITHOUT NOTICE