RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design



Similar documents
RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

NEW PRODUCT ANNOUCEMENT

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits

Agilent Technologies 3000 Series Oscilloscopes

U1602A Handheld Oscilloscopes, 20 MHz

Handheld Digital Storage Oscilloscopes 2510 Series

How To Test A Computer With A Powerline 2.5 (Powerline) And Powerline (Powerplant) (Powerboard) (Awn) (Ios) (Mini Computer) (Microphone) (Wireless) (

User Manual. Digital Storage Oscilloscope DSO25 / DSO100. Version No.: V 1.6

DSO-1062D/DSO-1102D/DSO-1202D different bandwidths. Digital Oscilloscope User Manual

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Analogue/Digital Analogue and Differential Oscilloscopes

Table of Contents. SAFETY INSTRUCTION...6 Safety Symbols... 6 Safety Guidelines... 7 Power cord for the United Kingdom... 9

How To Use A High Definition Oscilloscope

200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]

Embest DSO2300 USB Oscilloscope

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

DSO8000E SERIES HANDHELD OSCILLOSCOPE

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

Digital Storage Oscilloscopes TDS2000C Series Datasheet

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

User s Manual of OWON Colour Digital Storage Oscilloscope

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

20 cm (8 ) TFT (640 x 480 Pixel); Farben / colors

Keysight U2701A/U2702A USB Modular Oscilloscope

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Electronic Measurement Instruments. Selection Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

UT4000. Series USER MANUAL. Digital Storage Oscilloscope

Multi-Range Programmable DC Power Supplies 9115 Series

1.44 kw Programmable DC Power Supplies XLN Series

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Impedance 50 (75 connectors via adapters)

Table of Contents 1. USAGE PRECAUTIONS AND RECOMMENDATIONS GENERAL DESCRIPTION AND FEATURES FIRST TIME OPERATION...9

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent 54621A/22A/24A/41A/42A Oscilloscopes and Agilent 54621D/22D/41D/42D Mixed-Signal Oscilloscopes. User s Guide

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

FFT Spectrum Analyzers

FREQUENCY RESPONSE ANALYZERS

Lab 1: The Digital Oscilloscope

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

User Manual. SDS1000DL/CNL/CML Series. Digital Storage Oscilloscope. Version No.: V 1.0. SIGLENT TECHNOLOGIES Co,.LTD

High Power Programmable DC Power Supplies PVS Series

Agilent E5100A Network Analyzer

Digital Storage Oscilloscope TBS1000B-EDU Series Datasheet

Waveform Monitor Audio & Loudness Logging

Digital Storage Oscilloscope

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

USER S MANUAL. Hantek6022BE. V1.0.3

Arbitrary/Function Generators AFG3000C Series Datasheet

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

Agilent 4339B/4349B High Resistance Meters

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

OX 7100 Series AR RA NT Y

DC Electronic Loads 8500 series

khz to 2.7 GHz Spectrum Analyzer

Dash 18X / Dash 18 Data Acquisition Recorder

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

HP 54710A, 54710D, 54720A and 54720D Oscilloscopes

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

1. SAFETY INFORMATION

R&S ZNBT8 Vector Network Analyzer Specifications

One Port Network Analyzer

Dash 8Xe / Dash 8X Data Acquisition Recorder

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

R&S ZNC Vector Network Analyzer Specifications

i410/i1010 AC/DC Current Clamp

Analyser-Oscilloscopes

PERF10 Rubidium Atomic Clock

/ LCR HiTESTER Components measuring instruments

DL1620/DL1640/DL1640L

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 192B/196B-C/199B-C

Agilent U2761A USB Modular Function/Arbitrary Waveform Generator

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Electrical Resonance

64-CHANNEL INTEGRATED AMPLIFIER

S300. Big Screen Viewing. Bright projection 2800 ANSI Lumens. SVGA resolution, 15,000:1 contrast ratio. Low ownership costs - up to 6500 hrs lamp life

VG2435Sm :10 Ergonomic Multimedia Display. Overview. See More, Work More with a 16:10 Aspect Ratio Display

1701/22 FieldMonitor Management Interface Module

Digital Storage Oscilloscopes

Oscilloscope, Function Generator, and Voltage Division

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

HDO700 P FIBRE OPTIC TRANSMITTER

NI USB-5681 RF Power Meter Specifications

Automatic AES Change-Over

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Agilent InfiniiVision 3000 X-Series Oscilloscopes. User's Guide

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Transcription:

RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance. DS1000E series are designed with dual channels and 1 external trigger channel. DS1000D series are designed with dual channels and 1 external trigger channel as well as 16 channels logic analyzer. Applications Electronic Circuit Test Circuit Functional Test Logical Relation Between Singals Verification Circuit of Mixed Signal Test Education & Training Main Features Dual analog channels and 16 channels logic analyzer, 100MHz maximum bandwith, 1GSa/s maximum real-time Sample rate and 25GSa/s maximum equivalent Sample rate 5.6 inch and 64 k TFT LCD make the waveform displays more clear and vivid Abundant trigger types: Edge, Pulse Width, Video, Slope, Alternate, Pattern and Duration Unique adjustable trigger sensitivity enables to meet different demands Enable to measure 20 types of wave parameters and track measurements via cursor automaticlly Unique waveform record and replay Easy to Use Design Built-in help menu enables information getting more convenient Multiple Language User Interface, support Chinese & English input Support U disk and local files storage Waveform intensity can be adjusted To display a signal automatically by AUTO Pop-up menu makes it easy to read and use function Fine delayed scan function Built-in FFT function, hold practical digital filters Pass/Fail detection function enables to output testing results Math operations available to multiple waves Powerful PC application software UltraScope Standard configuration interface: USB Device,USB Host,RS-232 and support U disk storage and PictBridge print standards The new function Key Lock can meet the needs of industrial production Support for remote command control Feb. 2009 RIGOL Technologies, Inc.

Automatically Measure 20 Wave Parameters Cursor Measure Automatic measure DS1000E, DS1000D series oscilloscopes provide 20 types of wave parameters for automatically measuring, which contains 10 Voltage and 10 Time parameters. In cursor mode, users can easily measure by moving cursor. Besides, 3 types of cursor measurement are optional: Manual, Track and Auto. FFT cursor measure Multiple Trigger Pattern trigger Both DS1000E and DS1000D series contain abundant triggers: Edge trigger, Pulse Width trigger, Video trigger, Slope trigger Alternate trigger, Pattern trigger, Duration trigger(ds1000d) Especially the duration trigger is a new type from perfect combination of patten and pulse trigger. Unique function of adjustable trigger sensitivity is good for filtering possible noise from signal in order to avoid false triggers. 16 Channels Logic Analyzer Being equipped with 16 channels logic analyzer, DS1000D series mixed signal oscilloscopes achieve mixed signal measure coordinating with 2 analog channels. Each channel can be turned on or off independently, or in groups of 8(D7-D0 and D15-D8); also, you can set waveform size and threshold types or change the display position on screen for digital channel. Waveform Recording In virtue of waveform recording function from DS1000E and DS1000D, not only the outputs from two channels could be recorded, but also the waves outputted by Pass/Fail test could be easily recorded. Totally, up to 1000 frames of waves are available to record. Besides, users can analyze waves according to reall or save transient waves so as to get more exact datum. Pass/Fail Testing The Pass/Fail function monitors the changes of signals by comparing whether the input signal is within the pre-defined mask. The testing results not only can be displayed on screen or output by isolated pass/fail port, but also can be alarmed according to turn on system sound. Digital channels setup Waveform recording Measurement window Key Lock function UltraScope Software RIGOL provides powerful PC application software: UltraScope, which enables to: Capture and measure wave; Perform local or remote operation; Save waves as.bmp format; Save files as.txt or.xls format; Print waveforms. Key Lock Pass/Fail testing This function is widely used in most productions. All keys are locked except F1 to F5 and MENU ON/OFF in this mode. To lock the keyboard, use menu; to unlock, correct code has to be input. Also, you can reset a new code if necessary. 1

Specifications All specifications apply to DS1000E, DS1000D Series Oscilloscopes and a probe whose attenuation switch is set to 10X unless where noted. To come up to these specifications, two conditions must be met firstly: The instrument must have been operated continuously for 30 minutes under the specified operating temperature. Do perform Self-Calibration operation through the Utility menu if the range of operating temperature variations up to or more than 5 C. NOTE: All specifications are guaranteed unless where marked typical. Specifications Bandwidth DS1102E DS1052E DS1102D DS1052D 100MHz 50MHz 100MHz 50MHz Acquisition Sample Modes Real-Time Sample Equivalent Sample Sample Rate 1GSa/s, 200MSa/s [1] DS1102X DS1052X 25GSa/s 10GSa/s Averages The waveform will be displayed one time while all the channels finish N times Sample, N could be selectable from 2, 4, 8, 16, 32, 64, 128 and 256 Inputs Input Coupling DC, AC, GND Input Impedance 1MΩ± 2%, in parallel with 15pF± 3pF Probe Attenuation Factors 1X, 5X, 10X, 50X, 100X, 500X,1000X Maximum Input Voltage 400V (DC+AC Peak, 1MΩ input impedance) 40V (DC+AC Peak) [1] Time Delay between Channel (typical) 500ps Horizontal Sample Rate Range Real-Time: 13.65Sa/s-1GSa/s Equivalent: 13.65Sa/s-25GSa/s Waveform Interpolation Sin(x)/x Record Length Scanning Speed Range (Sec/div) Channel Memory Depth Memory Depth Sample rate Mode (normal) (long memory) Single channel 1GSa/s 16kpts N.A. Single 500MSa/s channel Or lower 16kpts 1Mpts Dual 500MSa/s channel Or lower 8kpts 512kpts 2ns/div~50s/div, DS1102X 5ns/div~50s/div, DS1052X 1-2-5 Sequence Sample Rate and Delay ± 50ppm (any interval 1ms) Time Accuracy Delta Time Single: ± (1 Sample interval + 50ppm reading + 0.6 ns) Measurement Accuracy >16 averages: ± (1Sample interval + 50ppm reading + 0.4 ns) (Full Bandwidth) Vertical A/D Converter 8-bit resolution, all channels sample simultaneously [2] 2

Volts/div Range Maximum Input Offset Range Analog Bandwidth Single-shot Bandwidth Selectable Analog Bandwidth Limit (typical) Lower Frequency Response (AC 3dB) Rise Time at BNC (typical) DC Gain Accuracy DC Measurement Accuracy, Average Acquisition Mode Delta Volts Measurement Accuracy (Average Acquisition Mode) Trigger Trigger Sensitivity Trigger Level Range Trigger Level Accuracy (typical) applicable for the signal of rising and falling time 20ns Trigger Offset Trigger Holdoff Range Set Level to 50% (typical) 2mV/div~10V/div (at the input terminal connecting to BNC) Mmaximum input voltage on analog channel CAT I 300Vrms, 1000Vpk;instantaneous overvoltage 1000Vpk CAT II 100Vrms,1000Vpk RP2200 10:1:CAT II 300Vrms RP3200 10:1:CAT II 300Vrms RP3300 10:1:CAT II 300Vrms ± 40V(500mV/div~10V/div),± 2V(2mV/div~100mV/div) 100MHz (DS1102D,DS1102E) 50MHz (DS1052D, DS1052E) 80MHz (DS1102D, DS1102E) 50MHz (DS1052D, DS1052E) 20MHz 5Hz (at input BNC) <3.5ns, <7ns, respectively at 100M, 50M 2mV/div-5mV/div: ± 4% (In Sample or Average acquisition mode) 10mV/div-10V/div: ± 3% (In Sample or Average acquisition mode) When vertical displacement is zero, and N 16: ± (DC Gain Accuracy reading+0.1div+1mv) When vertical displacement is not zero, and N 16: ± [DC Gain Accuracy (reading+vertical displacement)+(1% of vertical displacement) + 0.2div] When vertical scale is between 2mV/div and 200mV/div, add 2mV more for setting value. When vertical scale is between 200mV/div and 10V/div, add 50mV more for setting value. Under same setting and condition, the voltage difference ( V) between any two points in the waves coming from the average of more than 16 waves have been acquired: ± (DC Gain Accuracy reading + 0.05 div) 0.1div~1.0div (adjustable) Internal ± 6 divisions from center of screen EXT ± 1.2V Internal ± (0.3div V/div)(± 4 divisions from center of screen) EXT ± (6% of setting + 200 mv) In Normal mode: pre-trigger (memory depth/ 2*Sample rate), delayed trigger 1s In Slow Scan mode: pre-trigger 6div, delayed trigger 6div 500ns~1.5s When input signal frequency 50Hz Edge Trigger Edge trigger slope Rising, Falling, Rising + Falling Pulse WidthTrigger Trigger Condition (>, <, =) Positive pulse, (>, <, =) Nnegative pulse Pulse Width Range 20ns ~10s Video Trigger Video Standard Support for standard NTSC, PAL and SECAM broadcast systems. Line 3

Line Frequency number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) Slope Trigger Trigger Condition (>, <, =) Positive slope, (>, <, =) Negative slope Time Setting 20ns~10s Alternate Trigger Trigger on CH1 Edge, Pulse Width, Video, Slope Trigger on CH2 Edge, Pulse Width, Video, Slope Pattern Trigger [1] Pattern Type D0~D15 select H, L, X,, Duration Trigger [1] Pattern Type D0~D15 select H, L, X Qualifier >, <, = Time Setting 20ns~10s Measurements Voltage difference between cursors ( V) Manual Time difference between cursors ( T) Reciprocal of T in Hertz (1/ T) Cursor Voltage value for Y-axis waveform Track Time value for X-axis waveform Auto Cursors are visible when measure automaticly Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Auto Measure Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1 2, Delay1 2 Remarks: [1] For DS1000D Series; [2] Only one channel is available when the Sample rate is 1GSa/s. 4

General Specifications Display Display Type 5.7inch. (145mm) diagonal TFT Liquid Crystal Display Display Resolution 320 horizontal RGB 234 vertical pixels Display Color 64K color Display Contrast (typical) 150:1 Backlight Brightness (typical) 300 nit Probe Compensator Output Output Voltage (typical) About 3Vp-p, amplitude Frequency (typical) 1kHz Power Supply Supply Voltage 100 ~ 240VAC RMS, 45~440Hz, CAT II Power Consumption Less than 50W Fuse 2A, T level, 250 V Environmental Ambient Temperature Operating 10 ~ 40 Non-operating -20 ~ +60 Cooling Method forced cooling by fan Humidity below +35 : 90% relative humidity +35 ~ +40 : 60% relative humidity Altitude Operating at 3,000 m or below Non-operating at 15,000 m or below Mechanical Width 303mm Dimensions Height 154mm Depth 133mm Weight Without package 2.3kg Packaged 3.5kg IP Protection IP2X Calibration Interval The recommended calibration interval is one year 5

Ordering Information Warranty Name of Product RIGOL DS1000E, DS1000D series oscilloscopes Standard Accessories Probe 2 (1.5m), 1:1, (10:1) Passive Probes A Power Cord that fits the standard of destination country An USB Cable A Data Cable A Positive Logic Probe(DS1000D series) 20 Logic Testing Nips(DS1000D series) 20 Logic Testing Cables(DS1000D series) A CD-ROM (including User s Guide and Application Software) An User s Guide Optional Accessories BNC Cable RS232 Cable DS1000E, DS1000D soft carrying case Very thank you for choosing RIGOL products! RIGOL Technologies, Inc. warrants that this product will be free from defects in materials and workmanship from the date of shipment. If a product proved defective within the respective period, RIGOL will provide repair or replacement as described in the complete warranty statement. For the copy of complete warranty statement or maintenance, please contact with your nearest RIGOL sales and service office. RIGOL do not provide any other warranty items except the one being provided by this summary and the warranty statement. The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose. RIGOL will not take any responsibility in cases regarding to indirect, particular and ensuing damage. Contact Us If you have any problem or requirement during using our products, please contact RIGOL Technologies, Inc. or the local distributors. Domestic: Please call Tel: (86-10) 8070 6688 Fax: (86-10) 8070 5070 Service & Support Hotline: 800 810 0002 9:00 am 5: 00 pm from Monday to Friday Or by e-mail: Service@rigol.com Or mail to: RIGOL Technologies, Inc. 156# CaiHe Village, ShaHe Town, ChangPing District, Beijing, China Post Code: 102206 Overseas: Contact the local RIGOL distributors or sales office. For the latest product information and service, visit our website: http://www.rigolna.com 6