LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL



Similar documents
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

S10I / S20I / S30I Solar Light Controller USER MANNUAL

View Star series. Solar Charge Controller INSTRUCTION MANUAL

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

User s Manual Before using the inverter, you need to read and save the safety instructions.

Solar Controller / Battery Charger User s Manual

itracer Series Maximum Power Point Tracking Solar Charge Controller OPERATION MANUAL

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

12 Volt 30 Amp Digital Solar Charge Controller

How To Control A Battery Cell Phone With A Battery Power Control System

How To Use A Power Supply Unit (Upu)

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

etracer series Network Maximum Power Point Tracking Solar Charge Controller OPERATION MANUAL

Portable Solar Kits Owner s Manual

Manual for Fire Suppression & Methane Detection System

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Charge Regulator SCR 12 Marine

User s Manual AURORA 1.2K/2.2K

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

, User s Manual

User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.

Solar charger controller User s Manual

Battery Power Inverters

Installation and Operating Instructions (for chargers shown below)

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

2 Installation Explanation

Tracer- BN Series. MPPT Solar Charge Controller. User Manual. Models: Tracer1215BN/Tracer2215BN Tracer3215BN/Tracer4215BN

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Manual. Solar Fountain Mobile Phone Charger

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

30W SOLAR CHARGING STATION

Online UPS. PowerWalker VFI 1000R/1U

User manual Rev 1.3 Contents

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

YSmart Technology Co.,Ltd

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ATLAS DC. Model: CSFDC B1 CSFDC B1/CSFDC B2 CSFDC B1/CSFDC B2

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Installation and Operating Instructions (for chargers shown below)

ADM1TE 5/30A DIN rail single phase two wire energy meter

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

E E V R E - R S - O S L O A L R

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Mobile Data Power Model: MDP-25

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd.

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

SOLAR POWER CONDITIONER Service Manual

1. User Safety Instructions

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

TIG INVERTER INSTRUCTION MANUAL

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Wind/solar hybrid controller instructions

Product Specification instalert Rapid Messenger Variable Message Sign

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

PSC-A5 Solar Charge Controller Manual

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

SOLAR POWER - THE NEW WAY TO RV!

HM-W536 Install Guide

Advantium 2 Plus Alarm

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Owner s Manual channel amplifier

PITE 3921 Battery Monitoring System User Manual P V1.0

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

How to read this guide

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

OUTPUT CABLE CONNECTIONS:

Single Phase Soft Starter

Rousseau 10. User Guide

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Solar Home System Kit Quality Standards

Conventional Fire Detection and Extinguishant Control System Specification

User Manual 1K/2K/3K Online UPS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Kelly KBS-L Brushless Motor Controller User s Manual

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

User Manual (English)

3000W Power Inverter

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Transcription:

EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation, use and troubleshooting, etc. Please read this manual carefully before using the product and pay attention to the safety recommendations in it.

LandStar LS1024B / LS2024B / LS3024B Solar Charge Controller Nominal system voltage 12 / 24VDC* Maximum PV input voltage 50V Nominal charge / discharge current LS1024B 10A LS2024B 20A LS3024B 30A *The solar charge controller has the system voltage 12/24V automatic recognition function and custom define function, and all charge, discharge and load control parameters can be modified. Warranty: The charge controller is warranted to be free from defects for a period of two years from the date of shipment to the original end user. Notice: Manufacture is not responsible for the damage of any part of controller due to operator's misuse, battery parameters mismatch, unreasonable system configuration, unauthorized repairment or exceeding the specified parameter.

Contents 1 Important Safety Information...1 2 General Information...1 3 Installation Instructions...2 3.1 General Installation Notes...2 3.2 Writing...3 4 Operation...4 4.1 LED Indicators...4 4.2 Setting Operation...5 5 Protection, Troubleshooting...6 5.1 Protection...6 5.2 Troubleshooting...8 6 Technical specifications...9

1 Important Safety Information Please inspect the controller thoroughly after it is delivered. If any damage is seen, please notify the shipping company or our company immediately. Keep the controller away from rain, exposure, severe dust, vibrations, corrosive gas and intense electromagnetic interference. There are no user serviceable parts inside the controller. Do not disassemble or attempt to repair it. 2 General Information LandStar B series solar charge controller adopts the most advanced digital technique and operates fully automatically. It has various unique functions: 12V/24V automatic identify or user-defined working voltage. High efficient Series PWM charging, increase the battery lifetime and improve the solar system performance. Use MOSFET as electronic switch, without any mechanical switch. Multiple load control modes, increase the flexibility of the load output Gel, Sealed, Flooded and user-defined battery type option. Adopt temperature compensation, correct the charging and discharging parameters automatically and improve the battery lifetime. New SOC method of calculating accurately displays the available battery capacity. Electronic protection: Overheating, over charging, over discharging, overload, and short circuit. Reverse protection: any combination of solar module and battery. With functions of current power calculation and real-time energy statistics recording, it is convenient for users to view charging and discharging energy of each day, month, year and total value. Use of standard Modbus communication protocol for RS-485 bus connections, making communication distance much longer and 1

communication protocol compatibility much better Support firmware upgrade 3 Installation Instructions 3.1 General Installation Notes Be very careful when working with batteries. Wear eye protection. Have fresh water available to wash and clean any contact with battery acid. Never short circuit the battery positive and negative terminals and wires which may cause explosion or fire. Install external fuses/breakers as required. Disconnect the solar module and fuse/breakers near to battery before installing or adjusting the controller. Confirm that power connections are tightened to avoid excessive heating from loose connection. Uses insulated tools and avoid placing metal objects near the batteries. Explosive gasses may be present during charging. Be certain there is sufficient ventilation to release the gasses. Avoid direct sunlight and do not install in locations where water can enter the controller. Loose power connections and/or corroded wires may result in resistive connections that melt wire insulation, burn surrounding materials, or even cause fire. Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications. Only charge the batteries that comply with the parameters of controller. Battery connection may be wired to one battery or a bank of batteries. The following instructions refer to a singular battery, but it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank. Select the system cables according to 3.5A/mm 2 current density. 2

3.2 Wiring 1, Connect components to the charge controller in the sequence as shown in above picture and pay much attention to the + (Red)and - (Black).Always power the battery First. 2, After power the battery, check the battery indicator on the controller, it will be green. If it s not green, please refer to chapter 5. 3, The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm. 3

4 Operation 4.1LED Indicators Charging Status LED indicator Load Status LED indicator Battery Status LED indicator Switch Button Indicator Status Description Green On Solid Normal Green Slowly Flashing In charging Green OFF No charge Green On Solid Normal Green Slowly Flashing Full Green Fast Flashing Over voltage Orange On Solid Under voltage Red Red On Solid Flashing Over discharged Battery over temperature Red On Solid Normal 4

Red Slowly Flashing Overload Red Fast Flashing Short circuit Charging, load and battery indicator (red)flashing simultaneously Charging, load and battery indicator(orange)flashing simultaneously System voltage error Controller overheating Switch Button Function 1) Manual Control ON/OFF of the load. 2) Resume to normal work after the fault is cleared up. 4.2Setting Operation Three methods to program the controller: 1-Remote Meter,MT50/MT100(Use standard network communication cable with CC-RS485-RS485-200U-MT) 2-Super Parameter Programmer, SPP-01(Use standard network communication cable with CC-RS485-RS485-200U) This method can realize one-key setting operation which is suitable for bulk quantity products setting or applied in the projects.. 3 PC monitoring setting software Solar Station Monitor (Use dedicated RS485 to USB communication cable with CC-USB-RS485-150U) 5

Through the remote meter and PC software, it can realize real-time monitoring, modification of control parameter, charge mode, load work mode, inquiry of failure information etc. WARNING: Connecting the controller with PC network communication port by network cable is forbidden. It may cause the damage to the components of the controller. Note: Please refer to the user manual of MT, SPP-01, and PC software for more details. Load Set 1.Manual Control (default) 2.Light ON/Off 3.Light ON+ Timer 4.Time Control Battery Type 1.Gel 2.Sealed(default) 3.Flooded 4.User 5 Protection, Troubleshooting 5.1 Protection PV Array Short Circuit If PV array short circuit occurs, clear it to resume normal charge automatically. Load Overload If the load current exceeds the rated current of controller( 1.05 times rated discharge current), the controller will disconnect the load. Overloading must be cleared up, then pressing the switch button. 6

Load Short Circuit Fully protected against load wiring short-circuit( 2 times rated discharge current). After one automatic load reconnect attempt, the fault must be cleared by restarting the controller or pressing the switch button. PV Reverse Polarity Fully protection against PV reverse polarity, no damage to the controller will result. Correct the miswire to resume normal operation. Battery Reverse Polarity Fully protection against battery reverse polarity, no damage to the controller will result. Correct the miswire to resume normal operation. Battery working voltage error If battery voltage does not match controller working voltage, controller will stop working. After correcting the voltage, the failure can be eliminated through pushing load button. Damaged Temperature Sensor If the temperature sensor short-circuited or damaged, the controller will be charging or discharging at the default temperature 25 to prevent the battery damaged from overcharging or over discharged. Overheating Protection If the temperature of the controller heat sink exceeds 85 C, the controller will automatically start the overheating protection and stop the charging and discharging. When the temperature is below 75, the controller will resume to work. High Voltage Transients PV is protected against smaller high voltage surge. In lightning prone areas, additional external suppression is recommended. Note: The controller has daily automatic fault recovery function which will reduce the manual operation and can intelligently eliminate the fault caused by non-actual hardware failure. 7

5.2 Troubleshooting Faults Charging LED indicator off during daytime when sunshine falls on PV modules properly. Green Battery LED indicator fast flashing PV array Possible reasons disconnection Battery voltage higher than over voltage disconnect voltage(ovd) Troubleshooting Check that PV and battery wire connections are correct and tight. Check the battery voltage. If it over high, disconnect the solar module immediately and change a new controller. Battery LED indicators orange Battery under voltage Load output is normal. Charging LED indicator will return to green automatically when fully charged. Battery LED indicators RED color and loads not working. Battery over discharged The controller cut off the output automatically. LED indicator will return to green automatically when fully charged. Load status indicator red and slow flashing Over load Remove or cut out the additional load and press the button, the controller will resume to work after 3s Load status indicator red and fast flashing Short circuit Clear short circuit and press the button, the controller will resume to work after 3s All the led indicator flashing (battery orange indicator flashing) Too high temperature of controller 8 When heat sink of the controller exceeds 85, the controller will automatically cut input and output circuit. When the temperature below 75, the controller will resume to work. Please reduce

the environment temperature, the power of solar module or the power of the load. All the led indicator flashing (battery red indicator flashing) SOC value incorrect System voltage error Choose the wrong battery type; Using the reconfigured profile of the user defined battery type. Check whether the battery voltage match with the controller working voltage. Please change to a suitable battery or reset the working voltage. If there is no abnormal, please press load button to clear the malfunction. Correct the right battery type; Using the configuration of the charging voltage compensation if choosing the user defined battery type and ignore the SOC 6Technical specifications Electrical Parameters Description Nominal System Voltage Max. PV input voltage Max. Battery Terminal Voltage Rated Battery Current Charge Circuit Voltage Drop Discharge Circuit Voltage Drop Self-consumption Temperature compensation coefficient Parameter 12 /24VDC 50V 34V LS1024B 10A LS2024B 20A LS3024B 30A 0.28V 0.20V 8.4mA/12V; 7. 8mA/24V -3mV/ /2V (Default) Grounding Positive grounding 9

Battery Voltage Parameters (parameters is in 12V system at 25, please use X 2 in 24V system) Control Parameters Battery charging Gel Sealed Flooded User setting Over Voltage 16.0V 16.0V 16.0V 9~17V Disconnect Voltage Charging Limit 15.0V 15.0V 15.0V 9~17V Voltage Over Voltage 15.0V 15.0V; 15.0V 9~17V Reconnect Voltage Equalize Charging 14.6V 14.8V 9~17V Voltage Boost Charging 14.2V; 14.4V 14.6V 9~17V Voltage Float Charging 13.8V; 13.8V; 13.8V 9~17V Voltage Boost Reconnect 13.2V; 13.2V 13.2V 9~17V Charging Voltage Low Voltage 12.6V 12.6V 12.6V 9~17V Reconnect Voltage Under Voltage Warning Reconnect 12.2V 12.2V 12.2V 9~17V Voltage Under Voltage 12.0V 12.0V 12.0V 9~17V Warning Voltage Low Voltage 11.1V 11.1V 11.1V 9~17V Disconnect Voltage Discharging Limit 10.6V 10.6V 10.6V 9~17V Voltage Equalize Duration 2 hrs. 2 hrs. 0~3 hrs. Boost Duration 2 hrs. 2 hrs. 2 hrs. 0~3 hrs. 10

Notes: 1.The default battery type is Sealed. For Gel, Sealed, Flooded battery type, the voltage point is fixed, unable to modify it. 2.User type is the user defined battery type. The default value is the same as sealed type. When modify it, please follow the below logistic relation: a ) Over Voltage Disconnect Voltage>Charging Limit Voltage Equalize Charging Voltage Boost Charging Voltage Float Charging Voltage >Boost Reconnect Charging Voltage; b ) Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage ; c) Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage Discharging Limit Voltage; d ) Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage Discharging Limit Voltage; e ) Boost Reconnect Charging voltage>low Voltage Disconnect Voltage. *Please carefully to select battery type. It will damage battery if the setting is incorrect. 11

Environmental parameters Environmental parameters Parameter Working temperature -35 to +50 Storage temperature -35 to +80 Humidity 95% NC Enclosure IP30 LS1024B Mechanical parameters Mechanical Parameter Parameter 138.6(5.46)x69.3(2.73)x37(1.46) Overall dimension mm/inches Mounting dimension 126(4.96) mm/inches Mounting hole size Φ4.3 Terminal 4mm 2 Net weight 0.13kg LS2024B Mechanical parameters Mechanical Parameter Parameter 159.6(6.28)x81.4(3.2)x47.8(1.88) Overall dimension mm/inches Mounting dimension 147(5.79)x50(1.97) mm/inches Mounting hole size Φ4.3 Terminal 10mm 2 Net weight 0.3kg LS3024B Mechanical Parameters Mechanical Parameter Parameter 200.6(7.9)x101.3(3.99)x57(2.24) Overall dimension mm/inches Mounting dimension 190(7.48)x70(2.76) mm/inches Mounting hole size Φ4.5 Terminal 10mm 2 Net weight 0.5kg 12

Final interpretation right of the manual belongs to our company. Any changes without prior notice! Ver2.1

BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel:010-82894112/ 82894962 Fax:010-82894882 E-mail:info@epsolarpv.com Website: www.epsolarpv.com