Online Vibration Monitoring



Similar documents
WATCHMAN Reliability Services Enhance OEM Service Center Revenue

Agile Project Execution

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

Practical On-Line Vibration Monitoring for Papermachines

ISA CERTIFIED AUTOMATION PROFESSIONAL (CAP ) CLASSIFICATION SYSTEM

Machinery condition monitoring software

Your advantages at a glance

B&B ELECTRONICS WHITE PAPER. Managed Ethernet Switches - Key Features for a Powerful Industrial Network

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

What to Look for in a Vibration Consultant By Alan Friedman, DLI Engineering. Introduction. The Most Basic Form of Vibration Analysis

Intelligent Vibration Monitoring

Condition Monitoring and Maintenance Systems. Condition Monitoring for Industrial Applications

PLCs and SCADA Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Visualize, Document & Keep Your Network Running!

NEW. EVEN MORE data acquisition and test stand automation

Tank Gauging & Inventory Management Solutions

Combined Cycle Control Overview

WIRELESS ASSET MONITORING

Computer Cabinet Environment Monitor

SPPA-D3000 Plant Monitor Technical Description

Optimizing and Securing an Industrial DCS with VMware

H.V.A.C. Design Plumbing Design

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR

RecipCOM. Expertise, reciprocating compressor monitoring and protection tailored to your needs

Wired versus wireless trade-offs

OpEx Advantages + Asset Optimization

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

PROPOSALS REQUESTED THE TOWN OF OLD ORCHARD BEACH POLICE DEPARTMENT FOR IP-BASED VOICE COMMUNICATION SYSTEM

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Using Big Analog Data and the Industrial Internet to Improve Operations at Duke Energy. Brian Hollingshaus Duke Energy - Maintenance & Diagnostics

Rajesh Kaza. Leadership Seminar. Technology to Enhance Operations and Maintenance Synergy

Application of Standard Project Management Processes in Fiber Optic Cable Plant Project Management. Introduction. Alfred Sankara, DigiBridge TelCo

! encor e networks TM

Wide-Area Optical Fiber Network Monitoring and Management System

PI System Case Studies in the Cement Industry

The Business case for monitoring points... PCM architecture...

Asset Condition Monitoring Solutions

Managed Service For IP VPN Networks

HMS Industrial Networks. Putting industrial applications on the cloud

Security Systems Intrusion Alarm

Square D Power Management Services. Complete Custom Solutions for Your Power System

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Analytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts

ON-LINE MONITORING OF POWER PLANTS

Easy and efficient asset management for your business

8 Steps to Selecting and Implementing Videoconferencing Solutions in Education

Stuart Gillen. Principal Marketing Manger. National Instruments ni.com

Remote Monitoring and Satellite Communications

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

Advanced Monitoring and Diagnostics:

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Aftermarket Technical Service Solutions for Pumping Technologies

11 Software License and Hardware Maintenance and Support Agreement Extensions

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

Monetising FTTx Networks: FTTx rollouts give operators the opportunity to apply lessons learnt from earlier technology evolutions

Efficient remote access to machines and plants with SIMATIC

CA Workload Automation Agents Operating System, ERP, Database, Application Services and Web Services

HMS Industrial Networks

net COMPETENCE MATRIX

Scope: Communications and Electronic Systems addressed in this section include:

Kevin Kochirka, ABB Turbine Automation, June 29, Flexible turbine control retrofits Webinar

Safety & Automation System (SAS) - How the Safety and the Automation Systems finally come together as an HMI

Critical Infrastructure & Supervisory Control and Data Acquisition (SCADA) CYBER PROTECTION

ABSTRACT This paper discusses the need, issues, and solutions for automated monitoring of centrifugal process pumps. Reducing energy and improving

Manage Essential Assets with Automated Monitoring

EMC Integrated Infrastructure for VMware

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

SERVICE SCHEDULE MANAGED HOSTED APPLICATIONS

SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist

White Paper November BMC Best Practice Process Flows for Asset Management and ITIL Configuration Management

ESP 20/20. Compressor Monitoring System

Introduction To SCADA and Telemetry

scalable data centre energy management solution

EAS End Users Service Maintenance Program Yukon Visual T&D Support Policy Paper Version 1.1, January 2016

INTRUSION DETECTION SYSTEM Section

Temperature Alert. LAN-based Temperature and Humidity Data Logger

This KnowledgeShare document addresses the main types of wireless networking today based on the IEEE standard.

Electronic Flow Switches

Linexcom Sdn Bhd. ict Group of Companies ver1.2

ViZion Installation Guide

SECTION 16 TRAFFIC/SAFETY SECTIONS 16.1, 16.2 AND 16.3 ARE UNDER DEVELOPMENT

Cost effective Predictive Maintenance solutions

Fire Alarm System Monitoring - CAN/ULC-S561-03

PLICSMOBILE: Measurement data via the mobile network

ISA108 Intelligent Device Management (IDM)

BACnet Automation Interface Module (Network Version)


City facilities that are currently part of the System are listed below. Other City facilities may be added in the future.

A Data Collection Revolution?

The Continuously Current Enterprise: Trends in lifecycle management of automation assets

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

Cosasco Wireless System

Transcription:

Brandon DeVier My Background 1992 B.S. Physics 3 years with Predict Technologies 13 years with DLI Engineering Online Vibration Monitoring Systems Experience Online Systems Product Manager 3 years planning, installing, start-up and monitoring Field Experience Pulp and Paper CHILE Food Manufacturer AUS Gasoline Pumping Station - MEX Oil Refinery HUN Wind Farms GB, CAN, & IA Distribution Center CA & WI Paper Products GA & KY Aluminum Manufacturer KY Power Plant (Coal Unloader) MD 2 Oil Rigs (10 Pumps ea.) GULF - Ongoing CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 2

Lessons Learned An Online Vibration Monitoring System is not a part number in a catalog. It is an Engineering Project and should be treated accordingly. Re-training the sales force Client misconceptions Online System capabilities Too few accelerometers No Tachometer Scheduling / Planning Assigning Responsibilities CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 3

CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 4

Identify Goals Type of online monitor? Protection Surveillance Both Why Monitor? Critical equipment Short interval - time to failure Machine accessibility Understand the application Focus on the machines and the best way to monitor them, reconciled with the capabilities of the system. CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 5

Identify Goals Consider how the machines fail, what types of faults can be found using vibration analysis, what is the best way to test the machine, where are the best places to locate sensors, and what are the conditions under which the machine can be tested. CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 6

Identify Goals 1. What machines will be monitored? 2. What identified machine faults can be detected and what results can be expected? 3. How will the system determine the Running state of the machine? 4. How often will machines be tested (criticality)? 5. What types of measurements will be collected? 6. What process variables will be monitored? (Will these be accessed from software or hardware?) 7. What types of sensors are required? 8. How many sensors will be required and where will they be mounted? 9. How will automated diagnostics function with these machines? 10. Collect all relative machinery component information CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 7

Identify Goals Other inputs / outputs DCS OPC / DDE PI Web Email XML CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 8

Research Vendors System Capabilities Wireless or cabled Power requirements Safety requirements (IP Rating) Intrinsic Safety Environmental Ask for References View a Live Demonstration Price and Warranty Integration capabilities CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 9

Plan the System 1. Understand the capabilities and limits of the system (cable length limitations, environmental limits etc) 2. Explore plant and machine layout and distances 3. Diagram system layout (sensors, junction boxes, hardware and Monitor locations) 4. Determine what enclosures may be necessary 5. Understand environmental issues and electrical installation regulations. (Intrinsically Safe areas, special conduit, etc.) 6. Determine computer network access points 7. Plan for expansion CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 10

Plan the system System Layout CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 11

Plan the System Hardware Requirements Inputs / Outputs Software Requirements Integration with existing systems Network Requirements IS/IT involvement Responsibilities Who will install system? Who will configure system? Who will monitor the system? CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 12

Plan the system IT/IS configuration Internal access, external access, FTP, Web, VPN In-house personnel vs. contractors vs. vendor Sensors, cables, and hardware components Installed during outage Network, Software, Configuration Installed while machines / plant is operational Assign responsibilities Electrical contractors Mechanical contractors IT / IS personnel Vibration Specialists CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 13

Plan the system 1. What are the roles of the individuals who will interact with the system? 2. What is your network infrastructure? 3. What network security issues exist? 4. Do people outside of the plant network need to access the system? 5. What happens if the system finds a machine fault? (Who will be notified and how?) 6. Will the monitoring system be integrated with other systems? 7. Who will manage the system? 8. Who will be responsible for analyzing data or signing off on reports? 9. Create a diagram of the software layout 10. Determine who will install and configure system software components and output adaptors CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 14

Plan the system Schedule Tasks CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 15

Procure the system Purchase spares 10% Extend the Warranty Verify quantities Verify components function properly CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 16

Installation Sensors and Cable Choose efficient (short) cable runs Tachometer for variable speed machinery Process parameters CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 17

Installation Main Components Proximity to machine Accessibility Security Configure for network access System and Software Installation Start the System CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 18

Installation System Integrity Verification Sensor checks Hardware configuration checks Wiring checks Data flow checks Data integrity checks Database configuration checks (in terms of defining sensors correctly in the database) Ethernet / Internet communication integrity Proper Is Running condition setting verification CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 19

Installation System Integration Configure System Software and applications Verify communication and data-flow with other systems Establish Baselines Review the vibration data and results Fine-tune the system Baseline Data Running condition parameters Alarm levels Data acquisition parameters CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 20

Monitoring the Online System Results Who will monitor? Maintenance Staff Engineering Staff Operators Management Remote monitoring service How often? Continuous, Daily, Weekly, etc. Reports What kind of report(s)? Who gets them? CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 21

System Maintenance and Ongoing Support Refresher training Technical support Data review Database audit services Remote monitoring services Failed sensors and cables Software / hardware upgrades Spare parts Re-configure the system when machines are overhauled or replaced by other models. CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 22

Avoid Pitfalls and Delays Too few sensors for accurate diagnostics A tachometer signal is especially important for variable speed machinery IT / IS involvement (network configuration) Validate Signals Sensors, cables, non-functioning hardware. Garbage In Garbage Out Poor planning / scheduling Lack of proper training Expectation of capabilities Monitor the Online System Results CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 23

Keys to Success Set Goals Proper Planning Scheduling Assign Responsibilities Monitor the Results CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 24

Questions? AzimaDLI 253 Winslow Way West Bainbridge Island, WA 98110 (800) 654-2844 http://www.azimadli.com CONFIDENTIAL Copyright 2008 Azima DLI 781-938-0707 25