HPC Update: Engagement Model



Similar documents
Sun Constellation System: The Open Petascale Computing Architecture

BIG DATA The Petabyte Age: More Isn't Just More More Is Different wired magazine Issue 16/.07

Sun in HPC. Update for IDC HPC User Forum Tucson, AZ, Sept 2008

Intel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

THE SUN STORAGE AND ARCHIVE SOLUTION FOR HPC

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

Fujitsu PRIMERGY Servers Portfolio

Fujitsu PRIMERGY Servers Portfolio

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS)

IBM System x family brochure

præsentation oktober 2011

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

UCS M-Series Modular Servers

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

Appro Supercomputer Solutions Best Practices Appro 2012 Deployment Successes. Anthony Kenisky, VP of North America Sales

FUJITSU Enterprise Product & Solution Facts

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

Cisco Unified Computing System Hardware

SUN BLADE 6000 CHASSIS

Oracle Exadata: The World s Fastest Database Machine Exadata Database Machine Architecture

Stovepipes to Clouds. Rick Reid Principal Engineer SGI Federal by SGI Federal. Published by The Aerospace Corporation with permission.

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

See BeYonD the LiMitS

How To Build A Cisco Ukcsob420 M3 Blade Server

SPARC T5-1B SERVER MODULE

FLOW-3D Performance Benchmark and Profiling. September 2012

ALPS Supercomputing System A Scalable Supercomputer with Flexible Services

PRIMERGY server-based High Performance Computing solutions

Primergy Blade Server

Virtual Compute Appliance Frequently Asked Questions

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Department of Mechanical Engineering

Sun Blade(TM) 6000 Modular System. Technical Training. Jacques Bessoudo Technical Marketing Systems Group Sun Microsystems Inc

Building Clusters for Gromacs and other HPC applications

IBM System x family brochure

Hadoop on the Gordon Data Intensive Cluster

Parallele Dateisysteme für Linux und Solaris. Roland Rambau Principal Engineer GSE Sun Microsystems GmbH

SMB Direct for SQL Server and Private Cloud

SUN HPC SOFTWARE CLUSTERING MADE EASY

Cisco UCS B460 M4 Blade Server


Current Status of FEFS for the K computer

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

A-CLASS The rack-level supercomputer platform with hot-water cooling

SUN/Oracle WSCA Price List. Please call (877) SUN-LATG (877) (504) Or Fax (504) Or

Introduction. Need for ever-increasing storage scalability. Arista and Panasas provide a unique Cloud Storage solution

How To Write An Article On An Hp Appsystem For Spera Hana

Cost Efficient VDI. XenDesktop 7 on Commodity Hardware

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

SUN ORACLE DATABASE MACHINE

JuRoPA. Jülich Research on Petaflop Architecture. One Year on. Hugo R. Falter, COO Lee J Porter, Engineering

Cisco SmartPlay Select. Cisco Global Data Center Promotional Program

Cisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage

An Oracle White Paper December Consolidating and Virtualizing Datacenter Networks with Oracle s Network Fabric

Oracle Virtual Networking Overview and Frequently Asked Questions March 26, 2013

CORRIGENDUM TO TENDER FOR HIGH PERFORMANCE SERVER

CONFIGURATION CONCEPTS SUN SPARC ENTERPRISE M-SERIES SERVERS. James Hsieh, Sun Systems Group. Sun BluePrints Online

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

Clusters: Mainstream Technology for CAE

Extreme Computing: The Bull Way

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

Kriterien für ein PetaFlop System

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

LS DYNA Performance Benchmarks and Profiling. January 2009

Cisco UCS B-Series M2 Blade Servers

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

Motherboard- based Servers versus ATCA- based Servers

HUAWEI Tecal E6000 Blade Server

Sun Microsystems Special Promotions for Education and Research January 9, 2007

HUAWEI Tecal E9000 Converged Infrastructure Blade Server

Elasticsearch on Cisco Unified Computing System: Optimizing your UCS infrastructure for Elasticsearch s analytics software stack

Pioneer DreamMicro. Blade Server S75 Series

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value

Fujitsu PRIMERGY BX Blade Server

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

ORACLE EXADATA DATABASE MACHINE X2-8

Michael Kagan.

New Storage System Solutions

Spare Parts Price List (Sorted by Orderable Marketing Part Number)

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

PCI Express and Storage. Ron Emerick, Sun Microsystems

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

Logically a Linux cluster looks something like the following: Compute Nodes. user Head node. network

Comparing the performance of the Landmark Nexus reservoir simulator on HP servers

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Unified Computing Systems

The following InfiniBand products based on Mellanox technology are available for the HP BladeSystem c-class from HP:

Cisco UCS B200 M3 Blade Server

A Study on the Scalability of Hybrid LS-DYNA on Multicore Architectures

ECLIPSE Performance Benchmarks and Profiling. January 2009

Optimized dual-use server and high-end workstation performance

Transcription:

HPC Update: Engagement Model MIKE VILDIBILL Director, Strategic Engagements Sun Microsystems mikev@sun.com

Our Strategy Building a Comprehensive HPC Portfolio that Delivers Differentiated Customer Value Providing complete and Integrated Solutions for targeted markets by combining unique Sun IP with best-in-class products Innovation built on Open Standards at the component, product & solution level Making HPC simpler and easier Ensuring design and delivery excellence using strategic engagement teams Extending value through partnerships 2

Strategic Engagements Team 1.5 years of effort focusing on definition, design, modeling, prototyping and build of a portfolio of highly integrated standards-based products that address high-end HPC and Enterprise needs Emphasis on technology adoption; engagement with HPC customers on bids; 20+ large systems pre-sold Strong alignments into engineering, manufacturing, marketing, services and delivery organizations to ensure integrated offerings as opposed to just integrated systems 3

Sun Constellation System Success TACC: World s largest Open Supercomputer KISTI: Largest supercomputing center in Korea Jülich: Germany s largest HPC center Sandia: Worlds first & largest QDR Torus configuration 4

Launched; Deliveries are underway Blade racks that support industry standard PCIgen2 EMs and 48 no compromise blades; integrated cooling doors (water or refrigerant) that achieve room neutral cooling at 32-35kW per rack 2x2 HPC blades with two dual-socket 95w Nehalem nodes & two onblade QDR (10 GHz) InfiniBand host adapter chips QDR 48-port leaf switch (NEM) integrated into the rack 648-port QDR IB switch for non-blocking Clos; optical 12x cables JBOD w/ SW RAID running Lustre Configuration options include cost optimized mesh/torus, dual rail IB, non-ib, variety of Intel, AMD and SPARC blades, 3rd party products A popular rack config: 192 Nehalem CPUs (9 peak TFLOPs), 6.1 TBytes/ sec peak memory bandwidth, and 0.77 TBytes/sec of peak InfiniBand bandwidth (only 32 cables), with simple, non-blocking scaling to 486+ TFLOPs and custom configs scaling to 2+ PFLOPs 5

The Chassis is the Rack Up to 48 Server Modules, Up to Eleven TFLOPS per Rack Chassis Monitoring Module (CMM) and Power Interface Module Features per Shelf: Up to 24 PCIe ExpressModules (EM) 1 to 12 Server Modules Up to 2 Network Express Modules (NEM) N+N Power Supply Modules Each PSU configurable to 5600W or 8400W 8 Fan Modules Front Back

Looking Forward There exists tremendous opportunity for innovative, open, industry standard HPC solutions Dramatic cost, performance, and operational efficiencies are achievable through intelligent system design The synergies between broad open community adoption and high-end HPC offerings remains strong 7

www.sun.com/ sunconstellationsystem

Sun Constellation System The World s First Open Petascale Environment Scales to over two Petaflops 20% floor space reduction 6x fewer cabling required 50% more compute density* sun.com/sunconstellationsystem *Using quad socket blades in a 42RU Rack 9

The Complete Picture Compute Cluster Management Development Environment Visualization Network Fabrics Parallel Storage Network Storage Archive Storage

Sun Constellation System Open Petascale Architecture Building Blocks Sun Grid Engine Provisioning Developer Tools Compute Ultra-Dense Blade Platform Fastest processors: SPARC, AMD Opteron, Intel Xeon Highest compute density Fastest host channel adaptor Networking Ultra-Dense and Ultra-Slim Switch Solutions 72 and 3456 port InfiniBand switches Unrivaled cable simplification Most economical InfiniBand cost/port Storage Linux Software Ultra-Dense Storage Solution Total HPC Cluster Management Most economical and scalable parallel file system building block Up to 48 TB in 4RU Up to 2TB of SSD Storage controllers in the rack Integrated developer tools Scalable Distributed Resource Management Provisioning, monitoring, patching Simplified inventory management 11

Sun Cooling Door Systems Up 6x More Efficient Than Traditional Cooling Systems New Passive Rear Door Heat Exchanger Design No Additional Fans means greater efficiency Up to 35KW Capacity Pumped Refrigerant Door (5600) Datacenter safe R134A refrigerant Compatible with Liebert XD systems Highest Energy Efficiency and smallest footprint Chilled Water Door (5200) Low investment for those already with water in the datacenter Economical for smaller installations Connects to bottom (raised floor) or top (ceiling) water supply source Sun Cooling Door 5600 Sun Cooling Door 5200 Fits in the Rear of Sun Blade 6048 chassis

Versatile Sun Blade Portfolio: Intel Xeon New X6250 Up to 2 Xeon CPU 5200/5400 Series Quad-Core Up to 64GB (16 Memory FBDIMM) On-blade GbE 2 On-blade SAS 4X SAS 1.0 On-blade InfiniBand N/A 2X PCIe 1.0 X8, 2X PCIe I/O PCIe X4 New X6270 X6275 X6450 Up to 2 Xeon 5500 Series Quad-Core 2X2 Xeon 5500 Series Quad-Core Up to 4 Xeon 7400 Series 4 or 6-Core Up to 144GB (18 DDR3 Up to 192GB (2X12 DDR3 DIMM) DIMM) 2 2 4X SAS 2.0 N/A N/A 2X QDR IB 4X PCIe 2.0 X8 2X PCIe 2.0 X8 Up to 192GB (24 FBDIMM) 2 4X SAS 1.0 N/A 2X PCIe 1.0 X8, 2X PCIe X4

Versatile Sun Blade Portfolio: Intel Xeon New Sun Blade X6270 Two Nehalem-EP 4-core CPUs 18 DDR3 DIMM Slots, up to 144GB (8GB DIMMs) 4x PCI Express Gen2 x8 interfaces 2x GbE and 4x SAS2 via NEM Four 2.5-inch disks (SATA, SAS, SSD) Compact Flash Media Hardware RAID Full onboard ILOM Service Processor New Sun Blade X6275 New, high density, dual node blade server Each node contains Two Nehalem-EP 4-core CPUs 12 DDR3 DIMM Slots, up to 96GB (8GB DIMMs) 1x PCI Express Gen2 x8 interface 1x Gigabit Ethernet port via NEM 1x Sun Flash Module (24GB SATA) option 1x Dual Port QDR IB HCA (optional*); interfaces with IB QDR Switch NEM (6048 chassis only) Full onboard ILOM Service Processor 14

Versatile Sun Blade Portfolio: AMD Opteron Sun Blade X6440 Server Module Sun Blade X6240 Server Module Four Quad-core AMD Opteron processors 2.2, 2.5, 2.7 GHz with 6M L3 Cache 32 DDR2 DIMM, Up to 256GB Hardware RAID: optional 0, 1, 5, 6 Two Quad-core AMD Opteron processors 1.9, 2.1, 2.3, 2.5GHz 16 DDR2 DIMM, up to 64GB Four 2.5-inch SATA or SAS disks Hardware RAID 0, 1, optional 5, 6

Massive Scaling, Performance and Reduced Complexity Single Blade 10 x Scaling Using x64 architecture Sun Blade 6000 Single Rack 4.8 x Scaling 768 Cores 8.2 TFLOPS Peak 288 x Scaling 4 Core Switches 13,824 Servers 2.39 PFLOPS Peak 16

Sun Blade 6048 InfiniBand QDR Switched Network Express Module New Industry s Only Chassis QDR Integrated Leaf Switch Dual Port DDR FEM or onboard QDR IB HCA per server module 2 Passthru GigE ports per server module Leverages x8 PCIe 2.0 midplane Compact design maximizes chassis utilization Designed for Highly Resilient Fabrics Two onboard 36-Port QDR IB switches Increased resiliency allowing connectivity; up to 8 Ultra-dense switches 3:1 Reduction in Cabling Simplifies Cable Management 30 ports of 4x IB QDR connectivity realized with only 10 physical 12x connectors

Sun Blade 6048 IB QDR Switched NEM Mid-plane provides 4x QDR InfiniBand connection to 12 Server Modules Blade 8 Blade 9 Blade 10 Blade 11 Blade 6 Blade 7 QDR InfiniBand Switch Switch 12x IB B12 B14 B9 B11 B6 B8 B3 B5 B0 B3 12x connections to Cluster IB Fabric InfiniBand External Connectors Ethernet Blade 1 QDR InfiniBand Blade 5 36 Port 12x IB 36 Port 12x IB Blade 4 12x IB Blade 3 Blade 0 12x IB Blade 2 12x IB 12x IB 12x IB 12x IB 12x IB A12 A14 A9 A11 A6 A8 A3 A5 A0 A3 GbE ports for Server Administration 18

Sun HPC Software, Linux Edition Open Source Visualization Software Total HPC Cluster Management Sun Studio Other compilers and tools Sun HPC ClusterTools Other MPIs Sun Grid Engine Other Distributed Resource Manager Sun xvm Ops Center onesis or Other Management/Monitoring Software NFS Lustre Linux Distro InfiniBand pnfs Sun x64 Sun IB HW: Sun Datacenter Switches Other IB and 10GbE: Voltaire, QLogic, Cisco,... 10 GbE Block and File Storage Sun Component 1 GbE Tape/Archive Future Sun Component Non-Sun Component Sun HPC Software Services Sun HPC Software, Linux Edition Open Source Applications Software Solutions, Services and Subscriptions ISV Applications

Sun HPC Software Solaris 10 and OpenSolaris Open Source Visualization Software Total HPC Cluster Management Sun Studio Other Compilers and Tools Sun HPC ClusterTools Other MPIs Sun Grid Engine Other Distributed Resource Manager Sun xvm Ops Center Other Management/Monitoring Software NFS SAM-QFS Solaris LDOMS ZFS DTrace FMA InfiniBand Lustre pnfs Sun x64 Other x64 IBM, Dell, etc Sun SPARC Fujitsu SPARC64 Sun IB HW: Other IB and 10GbE: 10 GbE 1 GbE Sun Datacenter Switches Voltaire, QLogic, Cisco,... Block and File Storage Sun Component Tape/Archive Future Sun Component Non-Sun Component Sun HPC Software Services Sun HPC Software, Solaris Edition Open Source Applications Software Solutions, Services and Subscriptions ISV Applications

Parallel Storage Sun Storage Cluster HA MDS Module Standard OSS Module Lustre and Open Storage providing a wide range of Scaling and Performance for a wide range of cluster sizes Breakthrough economics Up to 50% cost savings vs. competitors Simplified deployment and management of Lustre storage HA OSS Module 21

TACC Ranger 1.73 PB storage, 35GB/s I/O throughput, 3,936 quad-core clients Sandia Red Storm 340 TB Storage, 50GB/s I/O throughput, 25,000 clients Framestore The Tale of Despereaux 200TB Lustre file system averaged 1.2GB/s in sustained reads, peaks of 3GB/s, 5TB data generated per night from cluster of 4,000 cores interfacing with Lustre file system German Climate Research Data Centre (DKRZ) 272 TB, Lustre and Storage Archive Manager, 256 nodes with 1024 cores

THANK YOU Mike Vildibill mikev@sun.com