SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value
|
|
|
- Shona Parker
- 10 years ago
- Views:
Transcription
1 SUN FIRE X4170, X4270, AND X4275 SERVER ARCHITECTURE Optimizing Performance, Density, and Expandability to Maximize Datacenter Value White Paper April 2009 Abstract In compact 1U and 2U form factors, the Sun Fire X4170, X4270, and X4275 servers combine the power of a new generation of Intel Xeon processors with Sun s system engineering expertise. Based on Sun s Open Network System design approach, these servers offer the needed performance, density, and expandability to satisfy demanding datacenter applications, especially for virtualization and consolidation initiatives. This white paper describes the architecture of the Sun Fire X4170, X4270, and X4275 servers, including the processor technology, I/O subsystem, built-in system management features, and range of supported operating systems.
2 This Page Intentionally Left Blank Sun Microsystems, Inc.
3 Sun Microsystems, Inc. Table of Contents Executive Summary Managing Capacity and Complexity Introducing the Sun Fire X4170, X4270, and X4275 servers Comparing the Sun Fire X4170, X4270, and X4275 servers A choice of operating systems The Intel Advantage New Intel Core Microarchitecture Modular architecture Power management technologies Intel Xeon Processor 5500 platform Sun Fire X4170, X4270, and X4275 Server Architectures Sun Fire X4170 system-level architecture Sun Fire X4170 server overview Sun Fire X4170 server enclosure Sun Fire X4170 server front and rear perspectives Sun Fire X4270 system-level architecture Sun Fire X4270 server overview Sun Fire X4270 server enclosure Sun Fire X4270 server front and rear perspectives Sun Fire X4275 system-level architecture Sun Fire X4275 server overview Sun Fire X4275 server enclosure Sun Fire X4275 server front and rear perspectives System platform Memory subsystem Memory population guidelines I/O subsystem System network interfaces PCIe 2.0 expansion bus Integrated storage Enclosure features Power distribution Fan assemblies Rack mounting RAS features ILOM Service Processor and System Management Sun ILOM service processor Optimizing management flexibility Remote keyboard, video, mouse, and storage (RKVMS)
4 Sun Microsystems, Inc. Intelligent platform management interface New features in ILOM SNMP Sun xvm Ops Center Enterprise-Class Software Support The Solaris Operating System Linux environments Microsoft Windows environments VMware support Summary For more information
5 1 Executive Summary Sun Microsystems, Inc. Executive Summary Datacenter complexity, energy, and cost issues continue to plague businesses and their ability to operate effectively within tight budget constraints. In recent years, an increase in the number of collaborative, Web, and data-centric applications has driven up the number of datacenter compute servers, adding to the administrative workload and compounding an already difficult IT management task. Complexity can sometimes result in severe business impacts, slowing productivity, extending development cycles, and delaying time to market. While datacenters try to cope with increasing complexity, they strive to control energy and other operating costs, while still keeping pace with the growing demand for computing and storage resources. To achieve greater business and datacenter efficiencies and enhance agility, many small businesses and larger companies are turning to consolidation and implementing virtualization initiatives. For more than 25 years, Sun has focused on solving customer problems by engineering solutions based on innovative technologies that deliver differentiated value. Sun s Open Network System approach combines innovative technologies, cost-effective and industry-standard components, and Sun s expertise in delivering dense, highperformance systems. This focus, along with an emphasis on eco-responsibility, is evident in designs of a new Sun platform family the Sun Fire X4170, X4270, and X4275 servers which are ideal for supporting consolidation and virtualization. Using state-of-the-art Intel Xeon processor technology (codenamed Nehalem ), Sun has engineered powerful 1U and 2U systems that are well-suited for HPC, grid computing, database, Web infrastructure, as well as consolidation and virtualization. These systems offer density and expandability in compute, memory, storage, and I/O subsystems, including the integration of low-latency, enterprise-quality solid state disk (SSD) drive technology. These systems are also highly energy-efficient and offer flexible support for multiple operating systems the Solaris and OpenSolaris Operating Systems, Linux, Microsoft Windows, and VMware. The Sun Fire X4170, X4270, and X4275 servers showcase Intel s talent for creating highperformance commodity chipsets along with Sun s advanced engineering and quality system design. Engineered for mission-critical availability, these servers feature several redundant and hot-swappable components and built-in system management tools. With efficient front-to-back air flow, highly efficient power supplies, and Intel s built-in processor power management technologies, these servers are engineered to conserve valuable energy resources, which helps to lower day-to-day operational expenses. By taking advantage of Sun s expertise in Open Network System design, these servers deliver innovation that optimizes operational efficiency and economics in the datacenter.
6 2 Managing Capacity and Complexity Sun Microsystems, Inc. Chapter 1 Managing Capacity and Complexity Introducing the Sun Fire X4170, X4270, and X4275 servers To help IT managers optimize value and reduce complexity in the infrastructure, Sun offers a new series of Intel Xeon processor-based systems the Sun Fire X4170, X4270, and X4275 servers based on Sun s Open Network System approach. This approach blends cost-effective, industry-standard components with innovative technologies, yielding compact 1U and 2U servers with unprecedented density, high performance, and energy efficiency. The Sun Fire X4170, X4270, and X4275 servers offer: Advanced levels of performance.the Sun Fire X4170, X4270, and X4275 servers share a common motherboard that contains two sockets for Intel Xeon Processor 5500 Series (formerly Nehalem-EP). With new HyperThreading technology, these CPUs can provide twice as many compute threads as previous generation processors. They also support enhanced power management features, the new QuickPath Interconnect, and Intel Turbo Boost technology that helps to deliver new levels of performance while lowering power consumption. Remarkable density. Density is the cornerstone of the Sun Fire X4170, X4270, and X4275 server designs. When populated in a 42-rack unit (RU) enclosure, the 1U Sun Fire X4170 server facilitates a single rack with up to 84 processors, 756 DIMM slots and 126 PCI Express (PCIe) 2.0 slots. In a single 2U chassis, the Sun Fire X4275 server supports up to 12 terabytes of internal storage (based on 3.5-inch SATA devices). These servers provide the density needed for consolidation and virtualization initiatives many smaller servers can be merged into a single Sun Fire X4170, X4270, or X4275 server to conserve space, lower energy expense, and reduce costly administrative talent. Support for multiple operating systems helps to streamline consolidation, simplify virtualization, and diminish server sprawl. Extensive system expandability. The ability to expand a server over time reduces the need for additional capital acquisitions and lowers application lifecycle costs. The 1U Sun Fire X4170 server enables a maximum of eight internal 2.5-inch hard disk devices (HDDs) while the 2U Sun Fire X4270 server provides up to sixteen 2.5-inch devices and up to six 8-lane PCIe 2.0 slots. With an innovative new 2U chassis enclosure that can house 3.5-inch devices, the Sun Fire X4275 server supports up to twelve internal HDDs and up to six PCIe 2.0 slots. All three server models are available with four on-board Gigabit Ethernet ports, and can be configured with either SAS or SATA hard disk drives. In addition, these servers are designed from the ground up to accept lowlatency solid state disks (SSDs) for performance-intensive applications. Because these servers can easily integrate enterprise-quality flash technology and offer such expandability, they can scale easily to support new users, more transactions, and new 32-bit or 64-bit applications, enhancing longevity and increasing overall ROI.
7 3 Managing Capacity and Complexity Sun Microsystems, Inc. Improved energy efficiency. Sun offers a portfolio of eco-responsible products and computing solutions to address customers needs to reduce energy consumption. In the Sun Fire X4170, X4270, and X4275 servers, the Intel Xeon Processor 5500 Series incorporates new technologies that decrease power consumption when processing workloads diminish. When the workload is low, the new Intel Core Microarchitecture (codenamed Nehalem) adjusts power use, reducing processor frequency, limiting power to unused execution units in each core, or temporarily disabling Turbo Boost features, which together can help to decrease power and cooling requirements. High-efficiency power supplies in the server chassis also lower overall power consumption. Variable speed fans, disk carrier design, and front-to-back air flow help to effectively cool the system and maintain appropriate processor and system ambient temperatures, which also help to minimize the energy footprint. Enterprise-class high availability. The Sun Fire X4170, X4270, and X4275 servers are designed with enterprise-class RAS (Reliability, Availability, and Serviceability) features. To maximize uptime, systems include redundant hot-swappable fans and are configurable with redundant hot-swappable power supplies. Using a Sun StorageTek SAS RAID Host Bus Adapter (HBA), internal SAS or SATA disk drives can be configured for RAID 0, 1, 1E, 10, 5, 5EE, 50, 6, and 60 when mirroring is implemented, drives are also hot-swappable. Four integrated Gigabit Ethernet ports enhance network availability without consuming a PCIe 2.0 slot and can be implemented in failover configurations. On-board system management tools encourage remote, proactive monitoring and intervention. Simplified system management. To support out-of-band management, the Sun Fire X4170, X4270, and X4275 servers incorporate a service processor that features robust lights-out management capabilities. This built-in functionality allows administrators to monitor and manage systems remotely, enabling corrective action and minimizing unplanned downtime. New side-band management capabilities allow one of the four on-board Ethernet ports to be configured for system management, which can reduce the number of network switch connections needed. The Sun Fire X4170, X4270, and X4275 servers combine powerful compute performance with expandable storage, memory, and I/O resources. As a result, these systems are designed to scale up, scale out, and scale within, enabling implementation in a wide range of application architectures: Scale-up architectures.with multiple cores and processing threads, these servers are well-suited to scale for growing workloads that deliver Web, database, and other key infrastructure services. Scale-out architectures.with the Intel QuickPath interconnect technology, large memory capacities, internal storage, four Gigabit Ethernet ports, and highbandwidth PCIe 2.0 expansion for high-speed system interconnects (such as fiber
8 4 Managing Capacity and Complexity Sun Microsystems, Inc. channel and InfiniBand), these servers can scale to solve complex computing problems that demand intensive compute power and data bandwidth. Scale-within.With the ability to support industry-leading virtualization software (including VMware, Microsoft Hyper-V, and Sun xvm, these servers are ideal systems to consolidate applications within a single extensible platform. Figure 1 shows the 1U Sun Fire X4170 server and the 2U Sun Fire X4270 and X4275 server enclosures. Sun Fire X4170 Server Sun Fire X4270 Server Sun Fire X4275 Server Figure 1. Sun Fire X4170, X4270, and X4275 servers Comparing the Sun Fire X4170, X4270, and X4275 servers Sun established a de-facto standard for system design with its Open Network System approach by integrating and optimizing open compute, storage, networking and software technologies from across the company's portfolio to deliver high performing, efficient, and scalable systems. Following the same design approach, the Sun Fire X4170, X4270, X4275 servers are engineered to deliver operational efficiencies and optimize datacenter value. The three models are targeted as follows:
9 5 Managing Capacity and Complexity Sun Microsystems, Inc. The Sun Fire X4170 server is a compact enterprise-class x64 server that can power demanding mission-critical back office applications. The Sun Fire X4270 server is ideal for virtualization initiatives in branch office or departmental settings, or for moderate complexity data center consolidation needs. It features excellent expandability for memory, I/O, and a large number of internal drives, which helps to support demanding virtualization requirements. The Sun Fire X4275 server is an ideal storage server to drive near-line storage solutions for rich media or data warehousing applications. Its high density and storage capabilities encourage substantial savings in cost, energy usage, and datacenter space, which helps to optimize value. Table 1 summarizes features of the Sun Fire X4170, X4270, X4275 server platforms. Table 1. Feature Comparison for Sun Fire X4170, X4270, and X4275 servers Feature Sun Fire X4170 Server Sun Fire X4270 Server Sun Fire X4275 Server Chassis 1U 2U 2U Number of CPU sockets Supported processor type Processor system interconnect Intel Xeon Processor 5500 Series Intel QuickPath Interconnect Intel Xeon Processor 5500 Series Intel QuickPath Interconnect Number of memory slots Memory capacity Up to 144 GB (using 8 GB ECC RDIMMs) Up to 144 GB (using 8 GB ECC RDIMMs) Intel Xeon Processor 5500 Series Intel QuickPath Interconnect Up to 144 GB (using 8 GB ECC RDIMMs) Memory type DDR3 RDIMM DDR3 RDIMM DDR3 RDIMM Internal storage: Supported device size Internal storage: Number of devices and types Removable media 2.5-inch 2.5-inch 3.5-inch Up to 8 SAS/SATA HDDs (SAS RAID HBA required) or 6 SATA HDDs or 4 SSDs (without an HBA) Optional SATA DVD/ RW; internal port and compact flash socket for flexible internal boot devices Number of PCIe 2.0 slots Three total (1 x16, 2 x8) Up to 16 SAS/SATA HDDs or 8 SATA SSDs (SAS RAID HBA required) Optional SATA DVD/ RW; internal port and compact flash socket for flexible internal boot devices Up to 12 SAS/SATA HDDs or 8 SATA SSDs (SAS RAID HBA required) No DVD/RW option; internal port and compact flash socket for flexible internal boot devices Six total (all x8) Six total (all x8) Number of GigE ports 4 on-board 4 on-board 4 on-board Number of ports 2 front, 2 rear, 1 internal System management RAS components OS support 2 front, 2 rear, 1 internal 2 rear, 1 internal On-board ILOM service processor. Side-band management via on-board GigE port or through 10/100 Ethernet system management port Hot swappable and redundant power supplies, fans, disk drives; RAID 0, 1, 10, 1E, 5, 6, 50, 5EE, 60 provided via optional SAS RAID HBA Solaris OS, OpenSolaris, Linux (32/64-bit Red Hat or SuSE Linux), Microsoft Windows, VMware ESX Server
10 6 Managing Capacity and Complexity Sun Microsystems, Inc. As Table 1 shows, the systems share a number of features, including: Up to two Intel Xeon Processor 5500 Series (codenamed Nehalem-EP) Integrated memory controller supporting up to 1333 MT/s registered DDR3 memory modules (memory is organized in three channels per processor) Multiple point-to-point Intel QuickPath technology-based interconnects Turbo Boost mode and HyperThreading capabilities Intel 5520 chipset (Tylersburg-36D) and Intel 82801JR I/O Controller Hub (ICH10R) Large-capacity internal storage, including support for solid state drives (SSDs) as well as hard disk drives (HDDs) PCIe 2.0 expandability Built-in quad Gigabit Ethernet support An on-board ILOM service processor for system management Enterprise-class RAS features including redundant, hot-swappable power supplies, fans, and drives Support for multiple operating systems Notable differences between the Sun Fire X4170, X4270, and X4275 servers include: Chassis enclosure (1U versus 2U) Maximum number of devices supported for internal storage Support for 2.5-inch versus 3.5-inch internal storage devices PCI 2.0 expansion capabilities (three PCIe 2.0 slots versus six PCIe 2.0 slots) Multiple off-the-shelf configurations of each platform are available, along with a wide spectrum of options to tailor each system for specific workload requirements. The Sun Fire X4170, X4270, and X4275 servers offer the density and configurability necessary to realize operational, administrative, and energy cost-savings the goals of many IT strategic plans. A choice of operating systems To optimize flexibility and investment protection, Sun Fire X4170, X4270, and X4275 servers support a choice of operating systems, including: Solaris Operating System (OS) OpenSolaris Operating System Linux operating systems (32/64-bit Red Hat or SuSE Linux) Microsoft Windows Server VMware ESX Server Chapter 5 describes the OS releases supported as of this writing. Please see sun.com/x64 for the latest information on supported operating systems and environments.
11 7 The Intel Advantage Sun Microsystems, Inc. Chapter 2 The Intel Advantage Sun Microsystems, Inc. collaborates closely with Intel Corporation to bring to market a broad server family based on the latest Intel Xeon processor technology. In the Sun Fire X4170, X4270, and X4275 servers, Sun s well-known system engineering expertise combines with Intel s processor design proficiency to emphasize performance, quality, reliability, and eco-responsibility. Engineers at both companies work together to optimize system performance under the Solaris Operating System (OS) as well as under other operating environments. Looking to the future, Sun and Intel cooperate in efforts to enhance the Solaris OS, Java technologies, and other functionality that complements Intel Xeon processor and Sun server designs. The Sun Fire X4170, X4270, and X4275 servers incorporate Intel Xeon Processor 5500 Series (formerly codenamed Nehalem-EP), which includes the revolutionary new QuickPath interconnect and the Nehalem microarchitecture. Each server incorporates a common motherboard populated with up to two processors, allowing the system to deliver quick response times and high throughput for performance-hungry applications. Compatible with a legacy of IA-32 software, these 64-bit processors support a large volume of existing 32-bit applications as well as emerging 64-bit applications. This chapter introduces the new Intel Xeon processors and microarchitecture used in this Sun server family. For detailed information on these components, see the Web site sun.com/x64. New Intel Core Microarchitecture With each release of a new processor series, Intel tends to alternate between enhancing the manufacturing process (shrinking the processor die) and redesigning the core microarchitecture. Over a year ago, Intel transitioned to a 45nm manufacturing process that enabled smaller transistors, allowing the previous processor generation to consume less power, achieve faster switching times, and provide greater on-die density than the generation before. This year, Intel is introducing a totally new microarchitecture design (codenamed Nehalem ) in the Intel Xeon Processor 5500 Series at the same time reaping the benefits from its previous expertise with 45nm silicon manufacturing. This new Intel Xeon processor generation is targeted at delivering optimal performance for bandwidth-intensive, threaded applications, with a microarchitecture that features significant innovations over previous designs: Intel QuickPath technology. This new technology provides a high-speed, point-topoint interconnect between processors, memory, and I/O. The Intel QuickPath interconnect (QPI) links processors in a distributed shared memory design that
12 8 The Intel Advantage Sun Microsystems, Inc. enables high bandwidth and low latency memory access. Because it is a point-topoint interconnect, processors do not contend for a single bus when accessing memory and I/O, and do not compete for bus bandwidth, which enhances scalability. Each QPI port includes two unidirectional links that support from 4.8 up to 6.4 GT/s per link, enabling up to 12.8 GB/s bandwidth in each direction for a total bandwidth of 25.6 GB/s significantly higher than previous bus designs. Multiple processor cores. The microarchitecture design scales from 2 to 8 cores per die, with four cores in the Intel Xeon Processor 5500 Series. Integrated DDR3 memory controller. Implemented as a separate component in earlier architectures, the memory controller is now integrated on the processor die. The processor design creates a Non-Uniform Memory Access (NUMA)-style memory architecture since each processor in multi-socketed systems can access local memory (connected to the local memory controller) as well as remote memory connected to the second processor. In addition to independent channel mode operation in which each memory channel supports direct memory access, the integrated memory controller also supports the following two modes: Memory channel mode increases reliability through memory mirroring. In this mode, two memory channels operate as mirrors of each other. The same content is written to both channels simultaneously, creating data redundancy. As a consequence of mirroring, the amount of usable system memory reduces to half of the total physical memory installed. To use memory channel mode, both channels must be populated with identical DIMM types. Lockstep channel mode operates two memory channels in lockstep, increasing the reliability of each memory operation. In this mode, the cache line is split across two channels, both channels must be populated identically, and memory mirroring and sparing are not supported. Regardless of the mode in use, the integrated memory controller also increases data protection through support for demand and patrol scrubbing and single device data correction (SDDC). Demand and patrol scrubbing technology proactively searches system memory, repairing correctable errors. In the case of uncorrectable errors, the algorithm permanently marks the memory location as unreadable. x4 and x8 SDDC offers an advanced form of ECC technology that protects computer memory systems from any single memory chip failure. This technology can detect and correct 1-bit to 4-bit internal data and data pin failures within one DDR memory device, and detect up to 8-bit internal data and data pin failures within two DDR memory devices. SDDC performs this function by scattering the bits of an ECC word across multiple memory chips, such that the failure of any one memory chip affects only one ECC bit. (Note: x8 SDDC is only available in lockstep channel mode)
13 9 The Intel Advantage Sun Microsystems, Inc. Advanced cache model. Each core has an associated Level-1 (L1) instruction/data cache (64KB per core) and a large integrated Level-2 (L2) cache (256KB per core). Also, all cores on a die share access to an inclusive Level-3 (L3) cache. The L3 cache varies in size from four to eight MB, depending on the specific processor model. Extended SSE4 (Streaming SIMD Extensions). These processor extensions improve performance for XML, string, and text processing. Virtualization enhancements. Embedded virtualization technologies enable hardware-based assistance for I/O device virtualization, improved virtualization efficiency, and enhanced connectivity within a virtualized server. Intel HyperThreading (HT) technology. This technology provides multiple virtual threads per core, increasing performance for highly threaded applications. In the Sun Fire X4170, X4270, and X4275 servers, Intel Xeon Processor 5500 Series implement two threads per core. Intel Turbo Boost Technology. For both multi-threaded and single-threaded workloads, this technology increases performance by taking advantage of processor and system power along with thermal headroom. The Turbo Boost feature can increase performance up to two or three speed bins (266 or 400 MHz) above typical performance levels. Turbo Boost and HyperThreading capabilities vary according to specific processor models. Intel Intelligent Power Technology. When a processor workload decreases, unneeded components cores, cache and memory are put into sleep mode to reduce power consumption. Figure 2 depicts the microarchitecture of the Intel Xeon Processor 5500 Series. Core 0 Core 1 Core 2 Core 3 64KB L1 Cache 256KB L2 Cache 64KB L1 Cache 256KB L2 Cache 64KB L1 Cache 256KB L2 Cache 8MB Shared L3 Cache 64KB L1 Cache 256KB L2 Cache DDR3 Memory Controller Channel 1 Channel 2 Channel 3 QuickPath Interconnects QP0 QP1 QP2 QP3 3 x 64-bit 1.33 GT/s 4 x 20-bit 6.4 GT/s (up to 10.6 GB/s per channel) (up to 25.6 GB/s per link) Figure 2. Intel Xeon Processor 5500 Series
14 10 The Intel Advantage Sun Microsystems, Inc. Modular architecture The New Intel Core Microarchitecture (codenamed Nehalem) is extremely modular, allowing a range of implementations to meet a variety of application needs and price points. The diversity between processor types (Table 2) results from differentiation in the number of cores, the size of the on-die L3 cache, the speed of QPI links, and maximum speed to memory, as well as support for Turbo Boost mode and HyperThreading functionality. Table 2. DIfferentiation between microarchitecture implementations. Processor type Number of cores L3 cache QPI link speed Max memory speed Turbo Boost bins Hyper Threading Performance 4 8MB 6.4 GT/s 1333 MT/s 3 yes Volume 4 8MB 5.86 GT/s 1066 MT/s 2 yes Value 2-4 4MB 4.8 GT/s 800 MT/s N/A no The Sun Fire X4170, X4270, and X4275 servers are available with processors from the performance or volume processor class. Processors in these servers feature four cores, 8 MB of shared L3 cache, and Turbo Boost and HyperThreading capabilities. Power management technologies Continuing the trend of reducing the processor energy footprint, Intel has designed a microarchitecture that facilitates high performance while minimizing power consumption. Enhancements to the microarchitecture add a greater number of CPU power states and decrease latency when a core switches from one state to another. In fact, the Intel Xeon Processor 5500 Series has up to 15 operating states, offers a two microsecond state-to-state transition latency, and reduces CPU idle power to 10 watts. Power gates that reside on the die allow idle cores to go to a near-zero power state independently of one another. To further conserve energy, memory, QPI, and PCI Express circuitry can also transition to lower power states. Using DIMM self-refresh, DIMMs are automatically idled when all CPU cores in the system are idle. DIMM Clock Enable (CKE) automatically places idle DIMMs into a lower power state. QPI links and PCI Express lanes are also placed in reduced power states during periods of inactivity. The processor design helps to conserve power use, which can directly translate into energy savings and reduced operational costs. Table 3 lists typical power envelopes for Intel Xeon Processor 5500 Series configurable in the Sun Fire X4170, X4270, and X4275 servers (these are the processor models available as of this writing). Because of innovative power efficiencies in the microarchitecture, even the highest speed processors in the Intel Xeon Processor 5500 Series have a power envelope of only 95W in comparison to the previous generation of high-speed processors which exhibited a power envelope as high as 120W.
15 11 The Intel Advantage Sun Microsystems, Inc. Table 3. Power envelopes for Intel Xeon Processor 5500 Series in Sun Fire X4170, X4270, and X4275 servers Processor Processor speed QPI link speed Power Intel Xeon X GHz 6.4 GT/s 95W Intel Xeon X GHz 6.4 GT/s 95W Intel Xeon E GHz 5.86 GT/s 80W Intel Xeon L GHz 5.86 GT/s 60W Intel Xeon E GHz 5.86 GT/s 80W Intel Xeon Processor 5500 platform The Sun Fire X4170, X4270, and X4275 servers share the same motherboard and thus the same Intel Xeon 5500 Series Platform (codenamed Tylersburg-EP). Up to two processors interface to each other and to the Intel 5520 I/O Handler (IOH) over multiple Intel QuickPath technology interconnects. The IOH (codenamed Tylersburg-36D) interfaces to an Intel 82801JR I/O Controller Hub (ICH10R), enabling expandability and high I/O throughput. Each Intel Xeon Series Platform is designed to match processor performance with memory capacity, I/O expandability, and interconnect bandwidth. Chapter 3 includes system block diagrams and descriptions. For more information on the Intel Xeon Processor 5500 Series and the related platform, see sun.com/x64.
16 12 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Chapter 3 Sun Fire X4170, X4270, and X4275 Server Architectures The Sun Fire X4170, X4270, and X4275 servers are designed to provide best-in-class performance with unprecedented expandability and low power consumption. This chapter details physical and architectural aspects of the systems, highlighting similarities and differences between the server designs. The three server models share a common motherboard architecture up to two Intel Xeon Processor 5500 Series connect to an Intel 5520 I/O Handler (IOH) over multiple Intel QuickPath technology interconnects. The IOH provides PCI 2.0 expandability and interfaces to an Intel 82801JR I/O Controller Hub (ICH10R). Details about server subsystems (chipsets, memory subsystems, I/O subsystems, etc.) are given later in this chapter. Sun Fire X4170 system-level architecture Figure 3 and Figure 4 contain system-level block diagrams for Sun Fire X4170 servers. DDR3 DDR3 DDR3 Intel Xeon Processor 5500 Series QPI TM XEON QPI Intel 5520 Intel Xeon Processor 5500 Series TM XEON QPI PCIe x2 PCIe x2 DDR3 DDR3 DDR3 PCI 32bit 33 MHz 82575EB 82575EB AST2100 G S-2E 4207 TAN A1 GP Virtual Side-band Interface UART 2x 1GB Ethernet 2 & 3 2x 1GB Ethernet 0 & 1 Management 10/100 Ethernet Serial RJ-45 VGA Video PCIe 2x8 4 GB/s PCIe 2x8 4 GB/s PCIe 2x16 8 GB/s IOH ESI (PCIe x4) ICH10R LPC to SATA to IDE SATA IDE CD/DVD Compact Flash SATA 1x Internal 2.0 PCIe x8-2 PCIe x8-1 PCIe x16-0 SATA HDDs or SSDs 2x Rear 2.0 2x Front 2.0 Figure 3. Block diagram of Sun Fire X4170 server using internal controller to connect SATA devices
17 13 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Figure 3 shows a direct connection for up to six SATA HDDs or four SATA SSDs from the ICH10R, which features an integrated SATA-II disk controller. Figure 4 depicts a configuration with a SAS HBA card that supports up to eight internal SAS or SATA HDDs or four internal SATA SSDs. Note that RAID configurations are supported only through the use of the PCIe SAS HBA card as shown in Figure 4. DDR3 DDR3 DDR3 Intel Xeon Processor 5500 Series QPI TM XEON QPI Intel 5520 Intel Xeon Processor 5500 Series TM XEON QPI PCIe x2 PCIe x2 DDR3 DDR3 DDR3 PCI 32bit 33 MHz 82575EB 82575EB AST2100 G S-2E 4207 TAN A1 GP Virtual Side-band Interface UART 2x 1GB Ethernet 2 & 3 2x 1GB Ethernet 0 & 1 Management 10/100 Ethernet Serial RJ-45 VGA Video PCIe 2x8 4 GB/s PCIe 2x8 4 GB/s PCIe 2x16 8 GB/s IOH ESI (PCIe x4) ICH10R LPC to SATA to IDE SATA IDE CD/DVD Compact Flash 1x Internal 2.0 PCIe SAS/RAID Controller SAS/SATA HDDs or SATA SSDs 2x Rear 2.0 PCIe x8-2 PCIe x8-1 PCIe x16-0 SAS/SATA 2x Front 2.0 Figure 4. Block diagram of Sun Fire X4170 server with a SAS HBA Sun Fire X4170 server overview The Sun Fire X4170 server includes the following major components: One or two Intel Xeon Processor 5500 Series Up to 144 GB of memory (using 8 GB RDIMMs) populated in 18 Registered Dual Inline Memory Module (RDIMM) slots 2 GB, 4 GB, or 8 GB RDIMMs are supported (8GB RDIMMs will be available shortly after initial platform availability) Four on-board 10/100/1000 Mbps Ethernet ports Three low-profile PCIe 2.0 slots, one 16-lane and two 8-lane Up to eight internal 2.5-inch SAS/SATA HDDs or four SATA SSDs (with a SAS HBA) or six 2.5-inch SATA HDDs or four SSDs (without a SAS HBA card) Five 2.0 ports
18 14 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. An on-board ILOM service processor Up to two hot-swappable, high-efficiency power supply units (PSUs) for N+1 redundancy Seven hot-swappable, variable speed fan modules (for N+1 redundancy), each containing two fans operating under environmental monitoring Sun Fire X4170 server enclosure The Sun Fire X4170 server enclosure is designed to occupy one rack unit in a standard 19-inch rack. Table 4 gives system dimensions and weight. Table 4. Dimensions and weight of the Sun Fire X4170 server Dimension U.S. International Height 1.71 inches (1 RU) millimeters Width inches millimeters Depth 27.0 inches millimeters Weight 36 pounds kilograms maximum Sun Fire X4170 server front and rear perspectives Figure 5 illustrates the Sun Fire X4170 server s front and rear panels. System status indicators DVD drive Component status indicators ports Slots for 2.5-inch devices Redundant (N+1) power supply units PCIe 2.0 slots Slot 0 Slot 1 Slot 2 System status indicators Serial and network management ports 10/100/1000 Ethernet ports ports VGA port Figure 5. Sun Fire X4170 server, front and rear panels
19 15 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. External features and connections include: Front and rear status indicator lights, reporting locator (white), service required (amber), and activity status (green) for the system and components Up to eight 2.5-inch SAS/SATA HDDs or four SATA SSDs (using a SAS HBA), or six 2.5- inch SATA HDDs or four SATA SSDs (using the on-board controller) all HDD or SSD devices insert through the front panel One slimline, slot-accessible SATA DVD-RW, accessible through the front panel Five ports two on the front panel, two on the rear panel, and one internal (to attach internal boot devices) Up to two power supply units (for N+1 redundancy) with integrated fans, with each power supply having a single, independent AC plug on the rear panel Rear power-supply indicator lights, showing the status of each hot-swappable power supply Four 10/100/1000BaseT autosensing Ethernet ports, accessible on the rear panel Three PCIe 2.0 slots, in which low-profile cards can be installed from the rear panel Two management ports on the rear panel (one 10/100BaseT Ethernet port and one RJ-45 serial port) for default connections to the service processor. Any one of the four on-board Ethernet ports can also be configured as a system management port. VGA video port with an analog HD-15 VGA connector on the rear panel
20 16 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4270 system-level architecture Figure 6 contains a system-level block diagram for the Sun Fire X4270 server. A PCIe SAS HBA card is used to support internal 2.5-inch SAS or SATA storage devices, and connects to the SAS expander on the disk backplane. (The SAS expander cannot connect to the ICH10R on-board disk controller as that controller is SATA II only.) Any Sun Fire X4270 server with internal drives must have a SAS HBA regardless of type of drives. The Sun Fire X4270 server supports up to 16 internal SAS/SATA HDDs or up to eight internal SATA SSDs, all in a 2.5-inch form factor. Since SSD devices require full power at system initialization, the initial power-on surge limits the number of 32GB SSD devices to a maximum of eight in the Sun Fire X4270 server. The remaining eight drive slots can be populated with SAS HDDs, if desired. DDR3 DDR3 DDR3 Intel Xeon Processor 5500 Series QPI TM XEON PCIe2 x8 4 GB/s PCIe2 x8 4 GB/s QPI Intel Xeon Processor 5500 Series QPI TM XEON Intel 5520 DDR3 DDR3 DDR3 PCIe x2 PCIe x2 PCI 32bit 33 MHz 82575EB 82575EB AST2100 G S-2E 4207 TAN A1 GP Virtual Side-band Interface UART 2x 1GB Ethernet 2 & 3 2x 1GB Ethernet 0 & 1 Management 10/100 Ethernet Serial RJ-45 VGA Video PCIe2 Active Riser PCIe2 Active Riser PCIe2 x16 8 GB/s PCIe2 Riser IOH ESI (PCIe x4) LPC to SATA SATA CD/DVD PCIe2 Switch PCIe2 Switch ICH10R to IDE IDE Compact Flash PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 1x Internal 2.0 PCIe SAS/RAID Controller SAS/SATA SAS Expander x SAS/SATA HDDs or SATA SSDs 2x Rear 2.0 PCIe2 x8-5 PCIe2 x8-2 PCIe2 x8-4 PCIe2 x8-1 PCIe2 x8-3 PCIe2 x8-0 SAS + + 2x Front 2.0 Figure 6. Block diagram of Sun Fire X4270 server with SAS HBA
21 17 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4270 server overview The Sun Fire X4270 server includes the following major components: One or two Intel Xeon Processor 5500 Series Up to 144 GB of memory (using 8 GB RDIMMs) populated in 18 RDIMM slots 2 GB, 4 GB, or 8 GB RDIMMs are supported (8GB RDIMMs will be available shortly after initial platform availability) Up to sixteen internal 2.5-inch SAS/SATA HDDs or up to eight 2.5-inch SATA SSDs (using a PCIe SAS HBA) Four on-board 10/100/1000 Mbps Ethernet ports Six low-profile PCIe 2.0 slots, all 8-lane Five 2.0 ports An on-board ILOM service processor Up to two hot-swappable, high-efficiency power supply units (PSUs) for N+1 redundancy Six hot-swappable, variable speed fan modules (for N+1 redundancy), each with two fans operating under environmental monitoring and control Sun Fire X4270 server enclosure The Sun Fire X4270 server enclosure is designed to occupy two rack units in a standard 19-inch rack (Table 5). Table 5. Dimensions and weight of the Sun Fire X4270 server Dimension U.S. International Height 3.34 inches (2 RU) millimeters Width inches millimeters Depth 27 inches millimeters Weight pounds kilograms
22 18 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4270 server front and rear perspectives Figure 7 illustrates the front and rear panels of the Sun Fire X4270 server. System status indicators Component status indicators Slots for 2.5-inch devices DVD drive ports Redundant (N+1) power supply units PCIe 2.0 slots Slot 3 Slot 0 Slot 4 Slot 1 Slot 5 Slot 2 System status indicators Serial and network 10/100/1000 management ports Ethernet ports Figure 7. Sun Fire X4270 server, front and rear panels ports VGA port External features and connections include: Front and rear status indicator lights, reporting locator (white), service required (amber), and activity status (green) for the system and components Up to inch SAS/SATA HDDs or up to eight 2.5-inch SATA SSDs, which insert through the front panel and interface to a PCIe SAS HBA card One slimline, slot-accessible SATA DVD-RW, accessible through the front panel Five ports two on the front panel, two on the rear panel, and one internal (to attach internal boot devices) Up to two power supply units (for N+1 redundancy) with integrated fans, with each power supply having a single, independent AC plug on the rear panel Rear power-supply indicator lights, showing the status of each hot-swappable power supply Four 10/100/1000BaseT autosensing Ethernet ports, accessible on the rear panel Six PCIe 2.0 slots, in which low-profile cards can be installed from the rear panel Two management ports on the rear panel (one 10/100BaseT Ethernet port and one RJ-45 serial port) for default connections to the service processor. Any one of the four on-board Ethernet ports can also be configured as a system management port. VGA video port with an analog HD-15 VGA connector on the rear panel
23 19 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4275 system-level architecture Figure 8 contains a system-level block diagram for the Sun Fire X4275 server. Because of its new 2U chassis and disk enclosure design, this server can support 3.5-inch storage devices using a PCIe SAS HBA card. The PCIe SAS HBA card connects to a SAS expander on the disk backplane. (The SAS expander cannot connect to the ICH10R on-board disk controller as that controller is SATA II only.) Any Sun Fire X4275 server with internal drives must have a SAS HBA regardless of type of drives. DDR3 DDR3 DDR3 Intel Xeon Processor 5500 Series QPI TM XEON PCIe2 x8 4 GB/s PCIe2 x8 4 GB/s QPI Intel Xeon Processor 5500 Series QPI TM XEON Intel 5520 DDR3 DDR3 DDR3 PCIe x2 PCIe x2 PCI 32bit 33 MHz 82575EB 82575EB AST2100 G S-2E 4207 TAN A1 GP Virtual Side-band Interface UART 2x 1GB Ethernet 2 & 3 2x 1GB Ethernet 0 & 1 Management 10/100 Ethernet Serial RJ-45 VGA Video PCIe2 Active Riser PCIe2 Active Riser PCIe2 x16 8 GB/s PCIe2 Riser IOH ESI (PCIe x4) LPC PCIe2 Switch PCIe2 Switch ICH10R to IDE IDE Compact Flash PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 PCIe2 x8 1x Internal 2.0 PCIe SAS/RAID Controller SAS/SATA SAS Expander x SAS/SATA HDDs or SATA SSDs 2x Rear 2.0 PCIe2 x8-5 PCIe2 x8-2 PCIe2 x8-4 PCIe2 x8-1 PCIe2 x8-3 PCIe2 x8-0 SAS Not Connected Figure 8. Block diagram of Sun Fire X4275 Server with SAS HBA The Sun Fire X4275 server supports up to 16 internal SAS/SATA HDDs or up to eight internal SATA SSDs that use a 3.5-inch form factor. Since SSD devices require full power at system initialization, the initial power-on surge limits the number of 32GB SSD devices to a maximum of eight SSDs. If desired, the remaining four drive slots can be populated with SAS HDDs.
24 20 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4275 server overview The Sun Fire X4275 server includes the following major components: One or two Intel Xeon Processor 5500 Series Up to 144 GB of memory (using 8 GB RDIMMs) populated in 18 RDIMM slots 2 GB, 4 GB, or 8 GB RDIMMs are supported (8GB RDIMMs will be available shortly after initial platform availability) Up to 12 internal 3.5-inch SAS/SATA HDDs or eight SATA SSDs (using a PCIe SAS HBA) Four on-board 10/100/1000 Mbps Ethernet ports Six low-profile PCIe 2.0 slots, all 8-lane Three 2.0 ports An on-board ILOM service processor Up to two hot-swappable, high-efficiency power supply units (PSUs) for N+1 redundancy Six hot-swappable, variable speed fan modules (for N+1 redundancy), each with two fans operating under environmental monitoring and control Sun Fire X4275 server enclosure The Sun Fire X4275 server enclosure occupies two rack units in the new Sun-designed 19-inch rack (Table 6). Table 6. Dimensions and weight of the Sun Fire X4275 server Dimension U.S. International Height 3.45 inches (2 RU) 87.6 millimeters Width inches millimeters Depth 30 inches millimeters Weight 65 pounds maximum kilograms
25 21 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Sun Fire X4275 server front and rear perspectives Figure 9 illustrates the front and rear panels of the Sun Fire X4275 server Component status indicators System status indicators Slots for internal 3.5-inch devices Redundant (N+1) power supply units PCIe 2.0 slots Slot 3 Slot 0 Slot 4 Slot 1 Slot 5 Slot 2 System status indicators Serial and network management ports 10/100/1000 Ethernet ports ports VGA port Figure 9. Sun Fire X4275 server, front and rear panels External features include: Front and rear status indicator lights, reporting locator (white), service required (amber), and activity status (green) for the system and components Up to inch SAS/SATA HDDs or eight SATA SSDs, which insert through the front panel and interface to a PCIe SAS HBA card Three ports two on the rear panel and one internal (to attach internal boot devices) Up to two power supply units (for N+1 redundancy) with integrated fans, with each power supply having a single, independent AC plug on the rear panel Rear power-supply indicator lights, showing the status of each hot-swappable power supply Four 10/100/1000BaseT autosensing Ethernet ports, accessible on the rear panel Six PCIe 2.0 slots, in which low-profile cards can be installed from the rear panel Two management ports on the rear panel (one 10/100BaseT Ethernet port and one RJ-45 serial port) for default connections to the service processor. Any one of the four on-board Ethernet ports can also be configured as the management port. VGA video port with an analog HD-15 VGA connector on the rear panel
26 22 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. System platform Refer back to the block diagrams earlier in this chapter. The Sun Fire X4170, X4270, and X4275 servers are based on the Intel Xeon Processor 5500 Series platform, which includes: Intel Xeon Processor 5500 Series. The Sun Fire X4170, X4270, and X4275 server motherboard includes two processor sockets. (Chapter 2 describes the processor microarchitecture.) An Intel 5520 I/O Handler (IOH). The IOH (codenamed Tylersburg-36D) features two QuickPath interconnects and 36 PCIe 2.0 lanes. Of the 36 PCIe 2.0 lanes, 32 connect to PCIe risers to enable PCIe 2.0 expandability. The remaining four lanes connect to two Intel 82575EB Gigabit Ethernet (Zoar) Controllers to support the four on-board Ethernet ports. An Intel 82801JR I/O Controller Hub (ICH10R). The ICH10R is interconnected to the IOH using one ESI (Enterprise South Bridge Interface) link. The ESI link is based on a 4-lane PCIe interconnect with proprietary extensions and offers a 2 GB/sec transfer rate. The ICH10R enables additional I/O functionality including support for system ports, the internal compact flash slot, and the SATA DVD/RW device (available on the Sun Fire X4170 and X4270 servers only). The ICH10R connects to the Aspeed AST2100 Service Processor using (for virtual devices), PCI (for video), and LPC (serial port). For more information on the Intel Xeon Processor 5500 Series chipset, see sun.com/x64. Memory subsystem The integrated memory controller and multiple DDR3 memory channels per processor help to provide high bandwidth for memory-intensive applications. DDR3 memory components offer greater density and run at higher speeds, but at significantly lower voltages than previous generation DDR2 memories. The Sun Fire X4170, X4270, and X4275 servers can be populated with DDR3 Registered ECC DIMM modules in either 2 GB, 4 GB, or 8 GB capacities. (8GB RDIMMS will be available shortly after the initial release of the servers.) Each processor features an integrated memory controller, which means that the systems adhere to a Non-Uniform Memory Access (NUMA) memory architecture the memory controller on one processor can access local memory as well as remote memory. The integrated memory controller supports DDR3 memories in three speeds 800 MT/s, 1066 MT/s, and 1333 MT/s although Sun only qualifies and offers 1066 MT/s and 1333 MT/s RDIMMs. When configuring system memory, it is important to note that DIMMs may run at slower than individually rated speeds depending on the CPU type, the number of DIMMs per channel, and the type of memory (speed, rank,
27 23 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. etc.). The speed at which memory is actually running is set by system BIOS at start-up, and all memory channels will run at the fastest common frequency. Memory population guidelines Each processor features three memory channels. Each channel supports three RDIMM slots, enabling up to 18 RDIMMs per system in a fully populated system. Memory slots in each channel are color-coded to simplify identification: Blue represents slot 0 White represents slot 1 Black represents slot 2 As a general rule to optimize memory performance, DIMMs should be populated in sets of three, one per channel per CPU, starting with the slot furthest from the CPU socket (in slot 0, the blue slot). Ideally each channel should be populated with equal capacity DIMMs, and if possible, with the same number of identical DIMMs (which helps to make memory performance more consistent). In a server with a single processor, the DIMM slots next to the empty CPU socket should not be populated. In general, it is better to populate quad rank (QR) DIMMs first, followed by dual rank (DR) DIMMs and/ or single rank (SR) DIMMs. 1 Optimizing memory for bandwidth Configurations with optimal memory bandwidth can be achieved using the Performance class of Intel Xeon Processor 5500 Series (see Table 2 on page 10) and memory components that run at 1333MT/s. To optimize a configuration for bandwidth, populate one single rank (SR) or dual rank (DR) DDR MT/s DIMM per channel (the use of quad rank (QR) DIMMs limits the number of DIMMs per channel to two, and restricts the maximum memory access speed to 1066 MT/s). Optimizing memory for capacity If three DIMMs per channel are populated to optimize for memory capacity, the memory access speed is reduced to 800 MT/s, regardless of the type of DIMMs (1066 MT/s or 1333 MT/s,). For this reason, using 1066 MT/s DIMMs is recommended to reduce the configuration cost. With all 18 slots populated using 8GB DIMMs, it is possible to achieve a maximum system memory capacity of 144GB. I/O subsystem With built-in headroom to expand systems and scale applications, the Sun Fire X4170, X4270, and X4275 servers feature expandability through a PCIe 2.0 expansion bus, internal storage options, four on-board Intel Gigabit Network Interface Controllers (NICs), and integrated capabilities. 1. Rank refers to the number of memory chips that a DIMM module has connected on any given data line. Sun offers only single rank (SR) and dual rank (DR) DIMMs at this time.
28 24 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. As shown in the block diagrams for the systems, the ICH10R provides connectivity for system ports, the internal compact flash, and the SATA DVD/RW device (available in the Sun Fire X4170 and X4270 servers only). To enable 2.0 functionality on the Sun Fire X4170, X4270, and X4275 servers, two ports go from the ICH10R to the rear panel and one link is routed to the internal port. On the Sun Fire X4170 and X4270 servers, two additional ports are routed from the ICH10R to the front panel. The ICH10R drives a -to-ide interface that supports an internal compact flash slot (Sun offers a 16GB compact flash device as an optional boot device). The ICH10R also includes a -to-sata interface to connect the internal SATA DVD/RW drive on Sun Fire X4170 and X4270 servers. System network interfaces The IOH has four PCIe lanes that interface to two Intel 82575EB Gigabit Ethernet (Zoar) Controllers. Each controller supports two on-board 10/100/1000 Mbit/sec Ethernet ports. Multiple on-board Gigabit Ethernet connections promote flexibility and enable configurations that support network interface failover. The four Gigabit Ethernet ports are numbered in sequence from left to right on the rear panel. Each port auto-negotiates its link connection, and LEDs above the port indicate the speed of the established link (green signifies that the established link is 1000 Mbit/ sec). The Ethernet interfaces also support PXE boot for booting over the network. A new feature in the Sun Fire X4170, X4270, and X4275 servers is the ability to configure any one of the four on-board Ethernet ports for side-band management. (See ILOM Service Processor and System Management on page 34.) When configured as a management port, one of the on-board Ethernet interfaces has two MAC addresses and requires two IP addresses (one for data and one for management). Just like the AST2100 Service Processor on the motherboard, the two Intel 82575EB Gigabit Ethernet controllers are powered from a stand-by power source from system power supplies. Even when power to the server is lost or turned off, the side-band management interface remains active to allow remote management. PCIe 2.0 expansion bus The Sun Fire X4170, X4270, and X4275 servers include a PCIe 2.0 expansion bus that can accommodate low-profile cards rated at 25W maximum. PCIe 2.0 doubles the interconnect bit rate, increasing the aggregated bi-directional bandwidth of a 16-lane link to approximately 16 GB/s. On each server model, three right-angle risers plug directly into the motherboard to enable PCI 2.0 expansion. Single slot 1U risers are used on the Sun Fire X4170 server versus dual-slot 2U risers on the Sun Fire X4270 and X4275 servers. Cards can be compliant with Revision 1.0a or 2.0 of the PCIe Card Electromechanical Specification, and are installed with a horizontal orientation.
29 25 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. On the Sun Fire X4170 server, the three PCIe 2.0 slots are numbered left to right (refer back to Figure 5). Slot 0 uses a x16 mechanical riser (Figure 10) and has 16 electrical lanes to the IOH. Slots 1 and 2 are located on x8 mechanical risers with eight electrical lanes. The risers are keyed to correctly insert into the motherboard. The passive riser splits 16 PCIe 2.0 lanes from the IOH into two sets of 8 lanes, one set for each riser slot. The active riser (Figure 11) uses an IDT PES24T6G2 PCIe 2.0 switch to expand eight PCIe lanes from the IOH into two x8 slots. The PES24T6G2 switch features six ports and twenty-four 5 Gbps PCIe 2.0 lanes supporting 5 Gbps, 2.5 Gbps, and mixed 5 Gbps/2.5Gbps modes. As implemented in these servers, the switch provides highperformance I/O connectivity and switching functions between the riser s x8 PCIe 2.0 upstream port and the two x8 downstream ports. It supports eight Traffic Classes (TCs) and one Virtual Channel (VC) with sophisticated resource management algorithms (including round robin, weighted round-robin, and strict priority schemes). The switch helps to support PCIe applications that demand high throughput and low latency, such as high throughput 10 Gigabit I/O cards, SATA controllers, and Fibre Channel HBAs. However, it is not recommended to insert more than one high bandwidth and latencyx8 electrical x16 mechanical Figure 10. PCIe 2.0 x16 riser for the 1U Sun Fire X4170 server (for Slot 0) The six slots on Sun Fire X4270 and X4275 servers are numbered left to right across the bottom (Slots 0 to 2) and then left to right across the top of the rear panel (Slots 3 to 5) refer back to Figure 7 and Figure 9, which show the rear panels of the Sun Fire X4270 and X4275 servers, respectively. Both 2U servers incorporate one passive riser (for Slots 0 and 3) and two active risers (for Slots 1 and 4, and Slots 2 and 5, Figure 11). Each 2U riser supports two PCIe 2.0 slots for I/O expandability and is keyed to correctly insert into the motherboard. Each 2U riser provides two 8-lane (electrical and mechanical) slots, for a total of six x8 PCIe 2.0 slots in each 2U server. x8 mechanical x8 electrical PCIe 2.0 switch Figure 11. PCIe 2.0 active riser for 2U Sun Fire X4270 and X4275 servers (Slots 1 & 4, and 2 & 5)
30 26 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. sensitive PCIe card in slots managed by a single switch at the same time (e.g., in Slots 1 and 4, or in Slots 2 and 5). By default, Slot 0 on Sun Fire X4170, X4270, and X4275 servers is used for the host bus adapter that connects to internal SAS/SATA HDDs or SATA SSDs. On the Sun Fire X4170 server, the SAS HBA can be moved to Slot 2 if desired. On the Sun Fire X4270 and X4275 servers, it can be moved to Slots 2, 3, or 5. (On all three server models, a heat sink interferes with internal cabling to the HBA if the HBA is installed in a center PCIe 2.0 slot.) Integrated storage The Sun Fire X4170, X4270, and X4275 servers offer large internal storage capacities for SAS or SATA HDDs and can also accommodate SATA SSDs. The servers differ, however, in the number and type of internal storage devices supported. Table 7 summarizes the differences. Table 7. Storage characteristics for Sun Fire X4170, X4270, and X4275 servers Feature Sun Fire X4170 Server Sun Fire X4270 Server Sun Fire X4275 Server Number of device slots Device form-factor 2.5-inch devices 2.5-inch devices 3.5-inch devices Maximum number of internal SAS HDDs 73 GB 15K 146 GB 10K Maximum number of internal SATA HDDs Maximum number of internal SATA SSDs 8 (with PCIe SAS RAID HBA) 8 SATA HDDs with PCIe SAS RAID HBA or 6 using embedded SATA controller 1, 2 4 SSDs using embedded SATA controller 2, 3 16 (with PCIe SAS RAID HBA) 16 (with PCIe SAS RAID HBA) 1 8 (with PCIe SAS RAID HBA) 3 12 (with PCIe SAS RAID HBA) 12 (with PCIe SAS RAID HBA) 8 (with PCIe SAS RAID HBA) 3 1 Populating the server with SATA HDDs requires a reduction in fan speed. This means that the server can support only lower power processors (CPUs that produce 85w max in the Sun Fire X4170 server or 95w max in the Sun Fire X4270 server). 2 The on-board SATA controller provides no RAID capabilities. Use the PCIe SAS RAID HBA card to implement RAID configurations. 3 Remaining drive slots can be populated with SAS HDDs connected to a SAS HBA. In the Sun Fire X4270 or X4275 servers, an existing SAS HBA can be used for SAS HDDs; in the Sun Fire X4170 server, a SAS HBA must be installed to support SAS HDDs. As Table 7 shows, the 1U Sun Fire X4170 server can support up to eight internal 2.5-inch HDDs, while the 2U Sun Fire X4270 server can house up to sixteen 2.5-inch internal HDDs. The Sun Fire X4275 server uses a modified 2U chassis and drive cage design that allows it to support up to twelve 3.5-inch internal HDDs. In the Sun Fire X4170 server, the on-board SATA controller supports up to six directly attached SATA HDDs or four SATA SSDs (although these configurations do not provide any RAID capabilities) a PCIe SAS RAID HBA card is required to fully populate all 8 slots with SATA or SAS devices and to implement RAID. In both the 2U Sun Fire X4270
31 27 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. and X4275 servers, the PCIe SAS RAID HBA is needed in all configurations to support internal storage options. Mixing SATA and SAS devices internally is supported (but not within a RAID volume). Available devices The following devices are available for the Sun Fire X4170, X4270, and X4275 servers (at the time of this writing): SAS HDDs 2.5 SAS disks: 73 GB 15K and 146 GB 10K (Note that 146 GB 15K and 300 GB 10K HDDs will be available shortly after initial server availability.) 3.5 SAS disks: 300 GB 15K, 450 GB 15K SATA HDDs 2.5 SATA disks: 500 GB 7200 RPM (shortly after initial server availability) 3.5 SATA Disks: 1000 GB 7200 RPM SATA SSDs 2.5 SFF SATA SSDs: 32 GB 3.5 SATA SSDs (2.5 SSD in 3.5 carrier with bracket adapter): 32 GB To support SATA disk drives in these servers, Sun incorporates an innovative bracket design that integrates dampening material to cushion the drive and minimize vibration. Solid state drives (SSDs) Modern servers are driving throughput levels that rapidly outpace the throughput capabilities of typical storage solutions. While many servers can achieve processing capabilities in excess of one million I/O operations Per Second (IOPS), today s fastest hard disk drives are only capable of about 300 to 400 IOPS. To match throughput more closely to server performance and meet the challenging demands of data-intensive applications, many datacenters implement large pools of high-speed disk drives. In some cases, a large buffer of expensive DRAM is also deployed so that the application s working set can be stored in memory to reduce latency. Flash technology provides a more economical alternative that can dramatically enhance application I/O performance while also operating with significantly better energy efficiency than conventional rotational hard disk drives (HDDs). The Sun Fire X4170, X4270, and X4275 servers support flash technology in the form of solid state drives (SSDs). Recent advances in the quality of flash technology have made SSDs an effective and reliable solution for enterprise storage, enabling a new strategy for implementing tiered storage solutions. Because SSDs offer low latency, they fall into a cost and performance sweet spot between mechanical drives and DRAM and thus can provide tremendous value in conjunction with I/O-intensive workloads. SSDs use a drive form factor and are directly inserted into drive bays specific to the Sun Fire X4170, X4270, and
32 28 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. X4275 servers. The servers operating system and BIOS views SSDs as standard SATA drives. Unlike rotational media, which spins up slowly at power-on, SSD devices require full power at system initialization. Because of this initial power-on surge, there are some limitations with the number of 32GB SSD devices initially supported in the Sun Fire X4170, X4270, and X4275 servers. The Sun Fire X4170 server can support a maximum of four SATA SSDs, while the Sun Fire X4270 and X4275 servers can support a maximum of eight SSD devices. For configurations that incorporate a SAS HBA, it is possible, however, to populate remaining empty device slots with SAS HDDs. Optimizing performance using SSDs Taking advantage of the performance and cost characteristics of an SSD requires an enabling technology that can transparently use it to drive better application and file system performance. Solaris ZFS allows datacenter architects to balance performance requirements against cost by using a variety of device types to store, archive, and access information. Creating a Hybrid Storage Pool in Solaris ZFS leverages the strengths of both rotational and solid state storage media. A Hybrid Storage Pool automatically places data on the most appropriate storage media to optimize performance and manage costs, and the ZFS file system can transparently cache data on SSDs without any need to modify applications. ZFS recognizes different media types and optimizes data placement to maximize system throughput. (For more information, see the solution brief Solaris ZFS Enables Hybrid Storage Pools Shatters Economic and Performance Barriers, available at solariszfs_solutionbrief.pdf). Sun Flash Analyzer To simplify the adoption of flash technology, the Sun Flash Analyzer tool can be used to detect I/O-intensive applications that can best benefit from the performance advantages of using flash technology. The Sun Flash Analyzer tool runs on the Solaris OS, Microsoft Windows, and Linux operating environments and can be downloaded from sun.com/flash/resources. For more information on flash technology in Sun products, see sun.com/flash. Drive cage design The ample storage density of the Sun Fire X4170, X4270, and X4275 servers is partly due to innovative drive carrier designs that facilitate effective air flow above and below each drive. Drives insert into a modular disk tray and cable-free disk backplane that increases reliability and serviceability. The carrier includes an ejection handle that simplifies drive removal drives are hot-pluggable when disk mirroring is configured. Drive status lights indicate Ready to remove, Fault, and Status.
33 29 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. In all three systems, the disks plug into a server-specific backplane board. In the Sun Fire X4270 and X4275 servers, a 28-port LSI SAS expander (the LSISASX28) facilitates large internal storage capacities. On the Sun Fire X4270 server, eight ports on the SAS expander connect to the SAS HBA, supporting switched connections for up to 16 SAS or SATA devices. On the Sun Fire X4275 server, six ports on the SAS expander connect to the HBA to support switched connections to up to inch SAS or SATA devices. Sun engineers modified the chassis of the Sun Fire X4275 server specifically to accommodate support for larger 3.5-inch internal storage devices. On the Sun Fire X4275 server, the SAS expander is located on a daughtercard (whereas it resides directly on the backplane in the 2U Sun Fire X4270 server). Also, the drive cage in the Sun Fire X4275 server is not removable. To minimize drive vibration for 3.5-inch devices, Sun added dampening material to the Sun Fire X4275 server drive cage and designed the fan deck with a floating spring mechanism that helps to isolate fan vibration. Disk Controller and I/O RAID Options The Sun Fire X4170, X4270, and X4275 servers support the following options for disk controllers: Embedded SATA II controller on the motherboard (Sun Fire X4170 server only). This controller supports up to six internal SATA HDDs or four SSDs (but it does not include any RAID support). Sun StorageTek SAS HBA based on LSI chipset. A low-profile card, the external version of this controller offers no RAID support and has two external 4-port SFF-8088 connectors. The internal version of this HBA has two internal 4-port SFF-8087 connectors and enables hardware RAID levels 0, 1, or 10. Sun StorageTek SAS RAID HBA, which supports 3 GB/sec SAS and hardware RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, and 60. Based on Adaptec and Intel technology, this HBA is an 8-channel, low-profile card with two 4-port SFF-8087 connectors. The card is available in two versions: one with internal connectors and one with external connectors. This HBA includes 256 MB of DDR2 memory on-board and a batterybacked write cache for 72-hour backup, which helps to deliver protected, high availability storage. Two cables with four lanes (each at 3 Gb/sec) each are wired from the SAS adapter to the disk backplane to control the internal HDD and SSD drives and provide high bandwidth. For the Sun Fire X4170 server, the four SAS links from the HBA connect directly to the SAS/SATA devices. In the case of the Sun Fire X4270 or X4275 server, the four SAS links connect to the LSISASX28 SAS expander. The SAS expander then provides connections to individual disks in the drive cage.
34 30 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. DVD/ Assembly A slim form-factor SATA DVD/RW assembly is available as an option to the Sun Fire X4170 and X4270 servers. The assembly provides an internal DVD-RW device as well as two ports accessible from the front panel. A locking handle allows the assembly to be safely secured and more easily extracted from the system chassis. Sun Fire X4170 and X4270 servers can also be ordered with an assembly that features two ports only (and no DVD device). (Note that EIDE DVD devices used in previous servers are not supported in the Sun Fire X4170 and X4270 servers since the new systems are designed for a SATA DVD device. The new SATA DVD devices are clearly labeled SATA on the device s exterior.) Enclosure features The Sun Fire X4170, X4270, and X4275 servers feature innovative chassis designs engineered to conserve system power and reduce cooling. The power and cooling efficiency of these systems exceeds that of many competitive systems configured with similar processing, memory, and storage capacities. The effective front-to-back airflow design helps to lower component temperatures, reducing the number of fans needed to cool the system. Processors also consume less energy under cooler temperatures, and lower component temperatures help to increase overall reliability. Key enclosure features include: Hex-shaped, honeycombed air inlet holes that enhance airflow and provide EMI shielding Front-mounted fans (located directly behind the disk drive cage) that pull air through the chassis, over system components, and exhaust it out the rear panel Innovative disk drive bracket design that enables efficient air flow above and below drive units Cable and component placement that helps to optimize cooling efficiency by channeling airflow effectively, as well as the reduction of internal cables to enhance airflow Fewer DC-to-DC conversions to improve power efficiency and generate less heat Power distribution Engineered for high availability as well as low energy consumption, the Sun Fire X4170, X4270, and X4275 servers can be configured with two highly-efficient, redundant, hotswappable AC/DC power supply units (PSUs), each with separate power cords. Configuring a system with a second power supply enables N+1 redundancy, supplying continuous power to the system if a single power supply fails. The PSUs differ between systems the Sun Fire X4170 server uses 760W PSUs while the Sun Fire X4270 and X4275 servers require 1050W PSUs. As shown in Table 8, the
35 31 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. power supplies are highly efficient, with an efficiency rating of at least 85% at 100% load. Sun makes available a Power Calculator on each Web site for the Sun Fire X4170, X4270, and X4275 servers ( This tool allows customers to estimate power consumption under SPECjbb2005 test workloads, from idle up to 100% load. Table 8. Power supply unit comparison System Maximum output power Maximum AC input current Power supply efficiency Sun Fire X4170 Server 760W At 100VAC and 760W output: 9.0A At 760W (100%) load: 87% Sun Fire X4270 and X4275 Servers 1050W At 100VAC and 1050W output: 12.4A At 1050W (100%) load: 85% Each PSU features a non-removable internal fan that supplies independent PSU cooling. Three light indicators display power supply status information ( AC, Fault, and OK ). The Sun Fire X4170, X4270, and X4275 servers use a Power Distribution Board (PDB) that provides connections between the power supplies and major system components. The PDB contains a single 10Amp 12V-to-5V DC-to-DC supply used to power the disk subsystem and the optional DVD-RW device. Fan assemblies The server enclosures are designed for efficient front-to-back air flow. Variable speed fans run under the control of the on-board Service Processor, which monitors processor temperatures and system ambient air temperature. Based on these readings, the fans operate at the lowest speeds possible to provide sufficient cooling conserving power usage, prolonging fan life, and reducing acoustical noise. Fan assemblies differ between the Sun Fire X4170, X4270, and X4275 servers. The Sun Fire X4170 server houses seven fan modules, with each module containing two 40mm, 10,000 RPM fans. In the Sun Fire X4270 and X4275 servers, there are six fan modules, with each module accommodating two hot-swappable 60mm fans. A green status light on a fan module indicates proper operation while an amber light indicates a fan fault. Fan modules on these systems are designed for redundancy a backup fan enables system continuity in the event of a fan failure. The fans are also hotswappable such that a module with a failed fan can be removed and a new fan module inserted without shutting down the system. On the top of the chassis, a fan access door allows the fans to be serviced while only partially pulling the chassis out of the rack. This simplifies cable management during fan replacement.
36 32 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. Rack mounting To shorten time-to-deployment, the Sun Customer Ready Systems program can preinstall Sun Fire X4170, X4270, and X4275 servers in a rack configuration. Alternatively, these 1U and 2U servers can be field-installed into Sun or other third-party racks that meet rack-mounting requirements. The Sun Fire X4170 and X4270 servers can be mounted in these racks: Third Party ANSI/EIA-310-D-1992 or IEC compliant racks in 19-inch/482.6mm panel-width series Sun Rack 938 Sun Rack 1038 and 1042 Sun Rack II 1042 and 1242 The Sun Fire X4275 server can be rack-mounted in the Sun Rack II It can also be rack-mounted in the Sun Rack II 1042 (with some limitations due to the depth of the chassis, particularly when using the cable management arm see the documentation for more details). As a part of its redesigned chassis, the Sun Fire X4275 server features new slide rail release levers (refer back to Figure 9). Pulling down on these levers unlocks the rails sliding mechanism, allowing the chassis to be pulled out of the rack for easier servicing. The following options are available to simplify rack mounting: Rack-Mounting Slide Rail Kit. This is a 4-point mounted slide rail kit (i.e., mounting points are located at the rack front and rear). Tool-less Rack Kit. As the name implies, this rack-mounting kit snaps into certain Sun and third-party racks without requiring any tools. Cable Management Arm. The cable management arm supports and protects cables as the server slides in and out of the rack. The Slide Rail Kit includes hardware to mount to rack rails with either 6mm threaded holes, #10-32 threaded holes, #10 clearance holes, or square unthreaded holes per ANSI/EIA 310-D-1992 or IEC standards. Note that not all third-party racks are compatible with the slide rail kit. Rack density will vary widely based on systems installed, power distribution (in-cabinet or external), power source (single-phase or three-phase), and whether redundant power is required. RAS features Corporate data and business information comprise critical business assets. Enterprise computing technologies strive to furnish a high degree of data protection (reliability), to provide virtually continuous application access (availability), and to incorporate procedures and components that help to resolve problems with minimal business impact (serviceability). Commonly referred to as RAS, these capabilities are a standard part of Sun s mission-critical computing solutions.
37 33 Sun Fire X4170, X4270, and X4275 Server Architectures Sun Microsystems, Inc. The Sun Fire X4170, X4270, and X4275 servers are engineered for hardware failure prevention, near continuous operation, fast recovery, and easy serviceability. RAS features for these systems include: High CPU density. Multiple Intel Xeon processors in 1U and 2U form factors enable density that increases overall availability. Hot-swappable redundant components. Mirrored disks, redundant fan modules, and redundant PSUs can be quickly and easily changed out, increasing system uptime. Accessible components for improved serviceability. Front-accessible, hot-swappable disk drives can be replaced quickly. The optional DVD/RW drive can also be removed without opening the top cover of the chassis. Fan modules and power supply units can be replaced without completely removing a system from the rack. A variety of RAID options, allowing customers to balance storage capacity, availability, and cost. The LSI-based Sun StorageTek SAS HBA with internal connectors supports RAID 0, 1, 1E, and 10E, while the Sun StorageTek SAS RAID host bus adapter supports RAID 0, 1, 10, 1E, 5, 50, 5EE, 6, 60 and also features a battery-backed disk write cache. Indicator LEDs on the front and back of the chassis. Easily visible LEDs allow problems to be identified and isolated easily. Diagnostic LEDs are also included on the motherboard. Integrated lights-out management (ILOM) capabilities. Standard on the Sun Fire X4170, X4270, and X4275 servers at no additional charge, the integrated ILOM service processor provides powerful tools for local or remote system management, simplifying administrative tasks, reducing on-site personnel needed, and lowering overall operational costs. (Chapter 4 discusses system management capabilities.)
38 34 ILOM Service Processor and System Management Sun Microsystems, Inc. Chapter 4 ILOM Service Processor and System Management The need for high availability in business-critical systems calls for robust and proactive system management. Like many other Sun servers, the Sun Fire X4170, X4270, and X4275 servers feature a built-in, hardware-based service processor that enables remote server monitoring, system management, and task automation capabilities that are consistent across much of the Sun server product line. Sun ILOM service processor The Sun Fire X4170, X4270, and X4275 servers embed an Aspeed AST2100 chip as the onboard service processor (i.e., the Baseboard Management Controller or BMC). The Aspeed AST2100 combines a graphics controller and a service processor into a single chip, saving space and power. It uses two ports for virtual devices and one 32-bit, 33Mhz PCI bus for video to connect to the ICH10R (refer back to system block diagrams in Chapter 3). The Sun ILOM service processor provides lights-out management, which can help organizations simplify system management. The service processor runs independently of the host platform, executing a robust, security-hardened operating system. Capabilities of the Sun ILOM service processor include the following: Full local and remote keyboard, video, mouse, and storage (RKVMS) access via redirection over IP, eliminating the need for KVM switches Monitoring and reporting of environmental, power, hardware, BIOS, and operating system events Remote power control, diagnostics, media attachment, and flash upgrades of the system BIOS and service processor software System configuration information retrieval User configurable serial console access through a physical port or redirected over IP Java-enabled remote console access across a secure Web connection Multi-level role based access with support for RADIUS, LDAP, and Microsoft Active Directory Service lookup of authentication data Simple Network Management Protocol (SNMP) V1, V2c, and V3 support For system management operations, the Aspeed AST2100 uses these connections: Two ports for virtual devices (both ports are routed directly on the motherboard between the AST2100 and the ICH10R) Two serial ports (one external, one to the ICH10R) Two Ethernet interfaces for IP-based management connections (one external for outof-band management, one to the Intel NIC controllers for side-band management)
39 35 ILOM Service Processor and System Management Sun Microsystems, Inc. One SVGA video port for local video output One 33 MHz, 32bit PCI connection to the ICH10R for video Management functions provided by the service processor are implemented by Sun ILOM 2.0 system management software. This software provides an Intelligent Platform Management Interface (IPMI 2.0) Baseboard Management Controller, platform control agents, diagnostics software, and Remote Keyboard, Video, Mouse, and Storage (RKVMS) drivers. Many other Sun servers incorporate this same firmware, providing organizations with a single, consistent, and standards-based management interface. Secure access to the service processor and associated ILOM software functions is available in several ways: Intuitive browser-based user interface (BUI) over SSL Distributed Management Task Force (DMTF) command line interface over Secure Shell (SSH) Redirection of the platform console, keyboard, mouse, and video to the ILOM Remote Console application SNMP v3 interfaces, providing easy integration with Sun xvm Ops Center, or thirdparty applications from companies such as Hewlett-Packard and IBM IPMI 2.0 command interface for remote management using IPMI-based tools, such as IPMItool Optimizing management flexibility While system management tools can play an important role in streamlining operations, organizations must consider the best approach for each environment. Executing management software directly on the host (with or without use of a service processor) is known as in-band management. Using a dedicated Ethernet or serial port to execute administrative tasks independently of the host is known as out-of-band management. Sharing a single Ethernet port for host and service processor network connectivity is called side-band management, which is enabled in these servers through a connection between the Ethernet controllers and the service processor (Figure 12). Table 9 offers a comparison of these management strategies. Intel 5520 PCIe x EB 2x 1GB Ethernet 2 & 3 IOH PCIe x2 Side-band Management Interface 82575EB 2x 1GB Ethernet 0 & 1 AST2100 G S-2E 4207 TAN A1 GP Management 10/100 Ethernet Figure 12. The Sun ILOM service processor supports side-band management
40 36 ILOM Service Processor and System Management Sun Microsystems, Inc. Table 9. Comparison of in-band, out-of-band, and side-band management Strategy Characteristics Benefits Ideal use cases In-band Relies upon operating systemresident software Management tasks utilize platform compute resources Use of a single network connection and switch port minimizes cost and complexity Heterogeneous environments with requirements to provide a common administrative tool across all platforms Out-of-band Utilizes a dedicated Ethernet or serial port for administrative traffic Continuous access to management capabilities even when host is disabled Environments with compute or bandwidth intensive applications Management tasks execute on an independent service processor Management tasks do not consume host resources Increased security by physically separating management traffic and server data Projects with complex management requirements or high-levels of administrative burden Side-band The host and service processor share an Ethernet port and are each assigned an independent MAC and IP address Management tasks execute on an independent service processor Continuous access to management capabilities even when host is disabled Management traffic uses part of the server data bandwidth Requires only one switch port, lowering implementation costs Minimizes processing overhead on the host Cost-sensitive environments The Sun Fire X4170, X4270, and X4275 servers offer extensive flexibility by supporting all three of these strategies in-band, out-of-band, and side-band management. Organizations can choose a single management method or use in-band management in tandem with out-of-band or side-band management approaches. The Sun Fire X4170, X4270, and X4275 servers provide out-of-band management across a dedicated 10/100 Mb Ethernet port or an RS-232 serial port on the Sun ILOM service processor. Side-band management is supported over one of the four Gigabit Ethernet interfaces shared between both the host and the service processor. When using a sideband management approach, both the platform and the service processor each get a unique MAC address and IP address for the shared physical Ethernet port. When configured, side-band management can provide all the benefits of out-of-band management at considerable cost savings by eliminating the need to consume a switch port for both management and platform connections. In-band server management In-band server management offers the opportunity for organizations to take advantage of industry-standard protocols and applications across all datacenter platforms. The Sun Fire X4170, X4270, and X4275 servers facilitate in-band server management by
41 37 ILOM Service Processor and System Management Sun Microsystems, Inc. supporting IPMI 2.0 and SNMP v1, v2c, and v3 standards. One of the following two options enable these operating system-resident platform management functions: IPMI with a Keyboard Controller Style (KCS) interface and an IPMI kernel driver SNMP agents Out-of-band and side-band management Out-of-band and side-band management approaches support the completion of administrative tasks without placing unnecessary burden on the host. This administrative strategy is desirable for performance-intensive environments. While inband management only works as long as the host operating system is up and running, out-of-band and side-band management are fully functional even while the host is powered off. For side-band management to work even while the host is shut down, the two dual-gigabit Ethernet (Zoar) controllers operate using stand-by power, similar to the service processor. Although out-of-band and side-band approaches differ with respect to network connectivity, these methods offer comparable capabilities and benefits. Based on serial port redirection (serial-over-lan), serial port connectivity to the ILOM Service Processor provides direct console access to the command line interface (CLI) and to the system console stream. The CLI is designed to follow the Distributed Management Task Force (DMTF) Command Line Protocol (CLP). Utilizing Ethernet connectivity, administrators can access a Web interface or command-line interface (CLI). A secure shell (SSH) session is required for access to the CLI and the Web interface supports both secure (https) and non-secure (http) access. Secure access is the default configuration for Web-based access. Remote keyboard, video, mouse, and storage (RKVMS) The ILOM Service Processor provides access to Keyboard, Video, Mouse, and Storage (RKVMS) remotely over IP. Remote video display is accomplished through the Java Web Start software known as Sun ILOM Remote Console. To set up a system as a remote console, ILOM Remote Console software is downloaded from the ILOM service processor to the target machine. 2 From this point onward, the ILOM Remote Console executes locally. Since ILOM Remote Console does not run locally on the server, it does not put overhead on the host. A single instance of ILOM Remote Console can open multiple sessions, enabling management of several remote servers simultaneously. ILOM Remote Console software can be used to redirect the BIOS and setup screens as well as all other platform video output. A true remote video console to the management console is provided by handling the input and output to and from virtual devices and the Sun Fire X4170, X4270, and X4275 servers. With 8-bit and 16-bit support, 8 MB of video memory, the SVGA display provide resolutions up to 1280 x ILOM Remote Console requires the installation of Java Runtime Environment 5.0 on the management console.
42 38 ILOM Service Processor and System Management Sun Microsystems, Inc. The two 2.0 ports connected to the ILOM service processor enable the remote keyboard, mouse and storage functions. The ILOM Remote Console software captures keyboard, mouse and floppy/cd/dvd input on the management console and redirects it over IP to the ILOM service processor. Keyboard, mouse and storage inputs are then transmitted over the ports to the server. The Sun Fire X4170, X4270, and X4275 servers interpret these inputs as originating from locally connected devices, which are referred to as virtual devices. ILOM Remote Console can also be used to boot the remote server from a local device. A virtual device can be a local physical device or an image file. Several types of devices can be redirected as virtual devices by ILOM Remote Console: CD/DVD-ROM Floppy flash disk drives CD/DVD-ROM image (.iso files) Floppy image (.img files) Intelligent platform management interface Intelligent Platform Management Interface (IPMI) platform management refers to the autonomous monitoring, logging, recovery, and inventory control features implemented in hardware and firmware. The key differentiation of Intelligent Platform Management is that these functions are independent of the main CPU, BIOS, and OS. There are two major components of platform management: the Baseboard Management Controller (BMC) and System Management Software (SMS). Intelligent Platform Management offers key capabilities for providing enterprise-class management for high-availability systems. The ILOM service processor provides autonomous sensor monitoring and event logging. Typical sensor-related events are an out-of-range temperature or voltage and fan failures. When an event occurs, it is noted in the system event log and made available to the system management controller. The system management controller is powered by power supply stand-by voltage and will function even when the server is powered down or the operating system has crashed. As a result, platform status can be obtained and recovery initiated even under situations in which in-band delivery mechanisms are unavailable. In modern systems, the Intelligent Platform Management Interface (IPMI) provides a hardware-level interface specification for monitoring and control functions. It defines a standard, abstract, message-based interface between the BMC and SMS and a common set of commands for operations such as accessing sensor values, setting thresholds, logging events, and controlling a watchdog timer. IPMI messages can be used to communicate with the BMC over serial and LAN interfaces, so software designed for in-
43 39 ILOM Service Processor and System Management Sun Microsystems, Inc. band (local) management can be re-used for out-of-band (remote) management simply by changing the low-level communications layer. IPMItool IPMItool is a simple command-line interface to systems that support the IPMI v2.0 specification. IPMItool provides the ability to remotely read sensor data and print sensor values, display the contents of the system event log, print field-replaceable unit information, read and set LAN configuration parameters, and perform remote chassis power control. IPMItool was originally written to take advantage of IPMI-over-LAN interfaces. This tool is also capable of interfacing with the system through a Linux kernel device driver such as OpenIPMI or the Solaris BMC driver within the Solaris 10 OS. IPMItool is available under a BSD-compatible license. System Management Software (SMS) is generally complex and is only part of a much larger management picture. However, system administrators and developers can use command-line scripting to manage these complex systems. IPMItool takes a different approach to SMS and provides a completely command-line oriented tool. IPMItool is not designed to replace the OpenIPMI library. Where possible, IPMItool supports printing comma-separated values for output to facilitate parsing by other scripts or programs. IPMItool is designed to run quick command-response functions that can be as simple as turning the system on or off, or as complex as reading in sensor data records and extracting and printing detailed sensor information for each record. New features in ILOM3.0 Since ILOM system management functionality is implemented in firmware, it can be easily upgraded even after a server is deployed. Shortly after the initial product release of the Sun Fire X4170, X4270, and X4275 servers, ILOM 3.0 will be available as a nocharge upgrade, offering enhancements over the current ILOM 2.0 functionality. ILOM 3.0 provides many new features and capabilities, including improved security, improved usability, and easier integration into the datacenter environment. Table 10 lists examples of new features for ILOM 3.0.
44 40 ILOM Service Processor and System Management Sun Microsystems, Inc. Table 10. Examples of ILOM 3.0 new features Category General Feature DNS support Timezone support Configuration backup and restore Restore to factory defaults Enhanced LDAP and LDAP/SSL support Java-based remote storage CLI Power management capabilities Ability to generate new SSH keys Scalability and Usability User-configurable filtering of hardware monitoring information in CLI and Web interface Use host name to access other services by name, such as LDAP, Active Directory, LDAP/SSL Security More granular user roles Predefined root and default accounts User SSH key authentication Ability to disable the network management port when you are using only the serial port Ability to disable individual services, such as IPMI, SSH, and KVMS, so that the port is closed Serviceability Data collection utility to diagnose system problems More information about ILOM 2.0 and 3.0 features is available in the documentation sets, which are available on docs.sun.com. SNMP The Simple Network Management Protocol (SNMP) provides remote access to monitor and control network devices and to manage configurations, statistics collection, performance, and security on a network. SNMP is a network management protocol used almost exclusively in TCP/IP networks. The Sun Fire X4170, X4270, and X4275 servers provide SNMP MIBs (Management Information Bases) to manage and monitor the servers using any SNMP-capable network management system, such as HP OpenView Network Node Manager (NNM), Tivoli, CA Unicenter, or IBM Director. The MIB data describes the information being managed, reflects current and recent server status, and provides server statistics. The ILOM service processor supports SNMP v1, v2c, and v3. SNMP v3 is enabled by default; v1 and v2c are disabled by default. SNMP sets may be enabled and disabled and are disabled by default. SNMP traps can be generated from within the service processor. An IPMI-specific trap, called a Platform Event Trap (PET), may also be generated. The following SNMP MIBs are supported: The system group and SNMP group from the RFC1213 MIB SNMP-FRAMEWORK-MIB SNMP-USER-BASED-SM-MIB SNMP-MPD-MIB ENTITY-MIB SUN-PLATFORM-MIB
45 41 ILOM Service Processor and System Management Sun Microsystems, Inc. Sun xvm Ops Center Sun xvm Ops Center software is a highly-scalable datacenter management platform that provides organizations with a fluid systems lifecycle management and automation process. The capabilities of Sun xvm Ops Center can help organizations simplify management of datacenter requirements such as server consolidation, compliance reporting, and rapid provisioning. This management platform helps provision and administer both physical and virtual datacenter assets in environments that include Sun Fire X4170, X4270, and X4275 servers as well as other Sun and non-sun hardware running Windows and Linux operating systems and the Solaris OS. Sun xvm Ops Center provides a single console to facilitate the following key capabilities within globally dispersed heterogeneous IT environments: Server discovery and inventory management Automatically scans and identifies servers across the network, even when powered off, allowing faster deployment and management of IT assets. Firmware and bare metal server provisioning Delivers automatic and hands off installation of bare-metal operating systems, RPMs and firmware, bringing new efficiencies to IT departments. Patch management and updating Provides up-to-date patch management tools for Red Hat, SUSE, and the Solaris OS, offering organizations greater control over datacenter plans and minimizing downtime. In addition, unique patch simulation capabilities remove uncertainty from the software update process. Managing and monitoring Securely and remotely manages users and heterogeneous datacenter assets, and proactively resolves problems by monitoring critical parameters, improving the security and stability of systems. Compliance reporting Provides an up-to-date view into the system state, patch status, and software portfolio, helping improve the speed and accuracy of report and compliance validation. These automation capabilities can be used in conjunction with configuration management investments to achieve knowledge-based change management. Taking advantage of Sun xvm Ops Center software can help organizations create a more compliant Solaris OS environment that requires less maintenance and recovery down time and can lead to considerable cost savings.
46 42 Enterprise-Class Software Support Sun Microsystems, Inc. Chapter 5 Enterprise-Class Software Support To provide both flexibility and investment protection, the Sun Fire X4170, X4270, and X4275 servers support multiple 32-bit and 64-bit operating systems, including the Solaris and OpenSolaris Operating Systems, Linux, Microsoft Windows, and VMware environments. Sun s support for multiple operating systems enables organizations to deploy a choice of application environments without having to shift hardware platforms when software requirements change. This added flexibility enables enterprises to reduce cost and complexity when supporting and managing solutions from multiple vendors, helping organizations to reduce risk and increase ROI. The Sun Fire X4170, X4270, and X4275 servers are certified to run the following operating system versions (subsequent releases of these operating systems are also expected to be supported and Sun-qualified): Solaris 10 10/08 Operating System (OS) OpenSolaris Operating System Red Hat Enterprise Linux 4.7 (32-bit or 64-bit) or Red Hat Enterprise Linux 5.3 (64-bit) SUSE Linux Enterprise Server 10 SP2 (64-bit) VMware ESX 3.5 U4 and VMware ESXi 3.5 U4 Windows Server 2003, Standard and Enterprise Editions (32-bit or 64-bit) Windows Server 2008, Standard, Enterprise, and Datacenter Editions, 32 and 64-bit Additional patches and drivers required to complete the installation of these operating systems are available from the Web site sun.com/download/ or on the Tools and Drivers CD-ROM provided with every Sun Fire X4170, X4270, and X4275 server. The drivers and installation scripts on the Tools and Drivers CD-ROM help to reduce the complexity of installing supported operating system distributions (since additional device drivers are included on the CD-ROM). Note that the Solaris 10 OS, Red Hat Enterprise Linux 5, SUSE Linux Enterprise Server 10, Windows Server 2008, and VMware ESX are available directly from Sun along with support contracts. In addition, the Sun Fire X4170, X4270, and X4275 servers come with the Solaris 10 OS pre-installed, or can be ordered with Windows Server 2003 or 2008 media. The Solaris Operating System Sun and Intel, as part of a strategic alliance, have been working together from design and architecture through implementation to ensure that the Solaris OS is optimized to unleash the power and capabilities of current and future Intel Xeon processors at the time of launch. Since 2007, engineering teams from the two companies have delivered a range of enhancements for Solaris on Xeon processors. They collaborated on optimizing how the Solaris platform and the New Intel Core
47 43 Enterprise-Class Software Support Sun Microsystems, Inc. Microarchitecture work together on the Intel Xeon processor 5500 series, with compelling results: Improved performance The Solaris OS takes advantage of the Intel Xeon Processor 5500 Series, including Intel Hyper-Threading Technology, Intel Turbo Boost Technology and the new Intel QuickPath Technology, resulting in significant performance improvements. Automated power efficiency and utilization The Solaris OS has been optimized to leverage Intel s power management functions, improving energy efficiency and performance-per-watt through Integrated Power Gates and Automated Power States. Increased reliability, availability, and serviceability (RAS) The Solaris Fault Management Architecture (FMA) infrastructure is enhanced to take advantage of the Intel Xeon processor 5500 series RAS features to provide an even stronger enterprise computing solution. Virtualization enhancements The Solaris OS delivers cost-effective virtualization through Intel Virtualization Technology features. Distributed under a commercial and open source licensing model, the Solaris 10 OS offers many innovative technologies that change the equation for organizations needing to reduce costs, minimize complexity, and eliminate risk. The Solaris 10 OS is optimized for Sun systems and supported on over one thousand third-party x86 systems. In addition, the Solaris 10 OS is free for download without requirement to purchase a support contract, offering an economic advantage over other communitybased operating system offerings. The Solaris 10 OS also includes more than 180 applications from the free and open source software (F/OSS) community, and thousands of others are freely available for download over the Internet. The Solaris OS includes features not found in any other operating system, including: Solaris Dynamic Tracing (DTrace) is a powerful tool that provides a true, system level view of application and kernel activities, even those running in a Java Virtual Machine. System administrators, integrators, and developers can use this dynamic instrumentation to reduce the time to diagnose problems from days and weeks to minutes and hours, providing faster data-driven fixes. Solaris Containers technology provides a powerful approach to virtualization and software partitioning, yielding many private execution environments within a single instance of the Solaris OS. Using this technology, organizations can improve resource utilization, reduce downtime, and lower solution costs. Sun Predictive Self Healing technology automatically diagnoses, isolates, and recovers from many hardware and application faults. As a result, business-critical applications and essential system services can continue uninterrupted in the event of
48 44 Enterprise-Class Software Support Sun Microsystems, Inc. software failures, major hardware component breakdowns, and software misconfiguration problems. Resource management facilities built into the Solaris 10 OS allow computing resources to be allocated among individual tasks and users in a structured, policy driven fashion. Using the Solaris OS resource management facilities to proactively allocate, control, and monitor systems. Resources such as CPU time, processes, virtual memory, connect time, and logins can be managed on a fine-grained basis to help organizations obtain more predictable service levels. Linux environments Sun offers and supports the leading Linux variants on the Sun Fire X2270 server, including Red Hat Enterprise Linux and Novell SUSE Linux Enterprise Server. As the leader in enterprise services for UNIX software, Sun brings decades of expertise to Linux environments. Sun support contracts for Linux provide all front-line support and transparent access to back-line support from Red Hat and Novell. Sun is one of the largest contributors to the open-source community. Areas of contribution include OpenOffice.org, Mozilla, GNOME, and X.org. In addition, Sun provides key software offerings for Linux including the following: Lustre parallel file system Sun Ray Server Software Sun xvm software StarOffice productivity suite Java Desktop Powered Program Sun Studio, Sun Java Studio Creator, and NetBeans IDE software MySQL database Microsoft Windows environments Organizations strive to reduce variety of platforms in the data center, even when a wide range of workloads are present. To help this effort, the Sun Fire X4170, X4270, and X4275 servers can run the Microsoft Windows operating environment. Indeed, these servers have passed stringent Microsoft compatibility test suites. Support contracts for Microsoft Windows are also available from Sun. This certification and support demonstrates Sun s commitment to providing the best platforms to run not only the Solaris OS and Linux, but Windows as well. VMware support Virtualization solutions from VMware help improve asset utilization, operational efficiency, and business agility. Sun offers the VMware Infrastructure product suite on Sun hardware systems with full support from Sun. VMware virtualization technology
49 45 Enterprise-Class Software Support Sun Microsystems, Inc. also combines with key Solaris 10 OS features such as, DTrace, Solaris Containers, and Solaris Predictive Self Healing software. As a result, organizations can create powerful IT solutions through virtualization. In fact, utilizing VMware virtual infrastructure software with the Solaris 10 OS for consolidation projects can increase system utilization by up to ten times. By taking advantage of technology from VMware, enterprises can further capitalize on the high-performance, scalability, and energy efficiency of the Sun Fire X4170, X4270, and X4275 servers.
50 46 Summary Sun Microsystems, Inc. Chapter 6 Summary IT departments face increasing pressure to deliver new services and satisfy escalating resource demands for new applications and users. The Sun Fire X4170, X4270, and X4275 servers offer exceptional system density, with compute, memory, networking, storage, and I/O expansion capabilities in compact 1U and 2U form factors. Leveraging a new generation of Intel Xeon processor technology and Sun s Open Network System approach in systems design, these platforms deliver new levels of performance and new levels of performance-per-watt in a rack-mountable chassis. Deploying these servers can create a more agile infrastructure that can scale to meet new business challenges while maintaining a small space and energy footprint, delivering new levels of efficiency and datacenter value. The Sun Fire X4170, X4270, and X4275 servers provide expandable, high-capacity resources needed for demanding HPC grid computing, Web infrastructure, database, and server consolidation and virtualization initiatives. These systems are ideal for a variety of industries, especially those installations where performance, density, and energy conservation are paramount. Given the speed and energy efficiency of these servers, IT departments can easily consolidate workloads and improve utilization at the same time preserving investments in x86 and x64 applications. Sun offers professional services, training, and integrated support to optimize server implementations and speed time-to-deployment. Experienced Sun specialists can assist with datacenter capacity planning, and consolidation and virtualization strategies. To experience the density and power of the Sun Fire X4170, X4270, and X4275 servers firsthand, contact your Sun account representative or visit For more information For more information on Sun Fire X4170, X4270, and X4275 servers and associated Intel chipsets, visit the Web sites: sun.com/x4170/ sun.com/x4270/ sun.com/x4275/ sun.com/servicessolutions/ sun.com/x64
51 47 Summary Sun Microsystems, Inc. This Page Intentionally Left Blank
52 Sun Fire X4170, X4270, and X4275 Server Architecture On the Web sun.com Sun Microsystems, Inc Network Circle, Santa Clara, CA USA Phone or SUN (9786) Web sun.com 2009 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, the Sun logo, Java, Lustre, MySQL, NetBeans, OpenSolaris, Solaris, StarOffice, StorageTek, Sun Fire, and Sun Ray are trademarks or registered trademarks of Sun Microsystems, Inc. or its subsidiaries in the U.S. and other countries. UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. SPEC and SPECjbb2005 are trademarks of the Standard Performance Evaluation Corporation. Information subject to change without notice. SunWIN # Printed in USA 04/09
SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE. Breakthrough Density Using Sun and Intel Technology
SUN FIRE X4150, X4250, AND X4450 SERVER ARCHITECTURE Breakthrough Density Using Sun and Intel Technology White Paper September 2008 Table of Contents Executive Summary................................................
How To Build A Sun Netra X4250 And X4270 Server With A Power Supply And Power Supply (Power Supply) For A Large Server (Power Management) (Power Control) (Netra) (Server) (Procedure
An Oracle White Paper August 2010 Oracle s Sun Netra X4250 and X4270 Server Architecture Executive Overview... 1 Introduction... 1 Managing Complexity... 3 Introducing Sun Netra X4250 and X4270... 3 Common
Server Architecture. The Sun Fire X2270. Solve greater computational challenges faster. White Paper March 2009. Abstract
The Sun Fire X2270 Server Architecture Solve greater computational challenges faster White Paper March 2009 Abstract Offering a compact form factor, the powerful performance of Intel Xeon Processor 5500
An Oracle White Paper. Oracle s Sun Server X4-2 and Sun Server X4-2L System Architecture
An Oracle White Paper Oracle s Sun Server X4-2 and Sun Server X4-2L System Architecture Introduction...3 Sun Server X4-2...4 Sun Server X4-2L...5 Comparing the Sun Server X4-2 and Sun Server X4-2L...6
SUN FIRE X4170 SERVER
SUN FIRE X4170 SERVER KEY FEATURES AND BENEFITS ULTIMATE IN ENTERPRISE PERFORMANCE FOR DATABASE MANAGEMENT OR WEB APPLICATIONS FEATURES Your business is under increasing pressure to deliver more services
FUJITSU Enterprise Product & Solution Facts
FUJITSU Enterprise Product & Solution Facts shaping tomorrow with you Business-Centric Data Center The way ICT delivers value is fundamentally changing. Mobile, Big Data, cloud and social media are driving
HUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
A Quantum Leap in Enterprise Computing
A Quantum Leap in Enterprise Computing Unprecedented Reliability and Scalability in a Multi-Processor Server Product Brief Intel Xeon Processor 7500 Series Whether you ve got data-demanding applications,
IBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers
Sun Microsystems Special Promotions for Education and Research January 9, 2007
Sun Microsystems Special Promotions for Education and Research Solve big problems on a small budget with Sun-Education s trusted partner for cutting-edge technology solutions. Sun solutions help your campus
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server HUAWEI FusionServer X6800 Data Center Server Data Center Cloud Internet App Big Data HPC As the IT infrastructure changes with
Intel Xeon Processor E5-2600
Intel Xeon Processor E5-2600 Best combination of performance, power efficiency, and cost. Platform Microarchitecture Processor Socket Chipset Intel Xeon E5 Series Processors and the Intel C600 Chipset
Tipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis
High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding
High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling
High Performance 1U Server The ASUS RS700-E7/RS8 1U server is based on dual Intel Socket R series processors (135W), designed with 24 DIMM slots to support up to 512GB memory. It features an optimized
SUN SERVER X4-2L SYSTEM
SUN SERVER X4-2L SYSTEM KEY FEATURES 2U enterprise-class server with flexible storage options Intel Xeon processor E5-2600 v2 product family CPUs Sixteen DIMM slots Six PCIe 3.0 slots Four 10GBase-T ports
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
Oracle Server X5-2. Product Overview
Oracle Server X5-2 Oracle Server X5-2 is designed from the ground up to be the best two-socket server for running Oracle Database in a clustered configuration and also for high-density virtualization environments
SUN SERVER X3-2L. Sun Server X3-2L server is the perfect integration of compute and storage in a single 2U enclosure for clustered
SUN SERVER X3-2L KEY FEATURES 2U enterprise-class server with flexible storage options Two Intel Xeon processor E5-2600 product family CPUs Sixteen dual inline memory module (DIMM) slots supporting two
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal
Oracle Sun Server X2-4 System Architecture: Virtualization Platform for Mission-Critical Applications
An Oracle White Paper June 2011; Revised July 2012 Oracle Sun Server X2-4 System Architecture: Virtualization Platform for Mission-Critical Applications Introduction... 1 Sun Server X2-4 system... 2 The
Cisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Cisco Unified Computing System Hardware
Cisco Unified Computing System Hardware C22 M3 C24 M3 C220 M3 C220 M4 Form Factor 1RU 2RU 1RU 1RU Number of Sockets 2 2 2 2 Intel Xeon Processor Family E5-2400 and E5-2400 v2 E5-2600 E5-2600 v3 Processor
SUN SERVER X4-2 SYSTEM
SUN SERVER X4-2 SYSTEM KEY FEATURES Compact and energy-efficient 1U enterprise-class server Two Intel Xeon processor E5-2600 v2 product family CPUs Sixteen DIMM slots Four PCIe 3.0 slots Four 10GBase-T
A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
U.S. Product Specifications Reference PSREF. Version 483, December 2015. ThinkServer Servers. Visit www.lenovo.com/psref for the latest version
U.S. Product Specifications Reference PSREF Version 483, December 2015 ThinkServer Servers Visit www.lenovo.com/psref for the latest version Contents Summary of Changes...1 ThinkServer Servers...4 ThinkServer
Intel Xeon Processor 3400 Series-based Platforms
Product Brief Intel Xeon Processor 3400 Series Intel Xeon Processor 3400 Series-based Platforms A new generation of intelligent server processors delivering dependability, productivity, and outstanding
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for
Power Redundancy. I/O Connectivity Blade Compatibility KVM Support
1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
IBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack, BladeCenter and tower servers 2 IBM System x family brochure Highlights IBM System x and BladeCenter servers help deliver
SPARC T5-1B SERVER MODULE
SPARC T5-1B SERVER MODULE KEY FEATURES 16 cores per processor deliver a remarkable 2.3x the system throughput over the previous generation 1.2x single-thread performance increase and double the L3 cache
Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms
IT@Intel White Paper Intel IT IT Best Practices: Data Center Solutions Server Virtualization August 2010 Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms Executive
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus
Acer AR180 F1 specifications
Product overview The Acer AR180 F1 dual-socket server delivers solid performance, scale-up flexibility, and optimized storage capacity in a 2U modular form factor. Comprehensive management utilities and
Fujitsu PRIMERGY BX924 S2 Dual-Socket server
Datasheet Fujitsu PRIMERGY BX924 S2 Dual-Socket server blade Datasheet for Red Hat certification Server Blade with virtualization fitness at all levels, be it compute power or I/O throughput The PRIMERGY
Cisco UCS B440 M2 High-Performance Blade Server
Data Sheet Cisco UCS B440 M2 High-Performance Blade Server Product Overview The Cisco UCS B440 M2 High-Performance Blade Server delivers the performance, scalability and reliability to power computation-intensive,
How To Build A Cisco Ukcsob420 M3 Blade Server
Data Sheet Cisco UCS B420 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
Intel X58 Express Chipset
Product Brief Intel X58 Express Chipset Highest performing desktop platform for extreme gamers and demanding enthusiasts Desktop PC platforms based on the Intel X58 Express Chipset and Intel Core i7 processor
HUAWEI Tecal E9000 Converged Infrastructure Blade Server
E9000 Converged Infrastructure Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The E9000 is a new-generation blade server that integrates computing, storage, switching,
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System An Ideal Solution for SMB Server Consolidation White Paper January 2011, Revision 1.0 Contents Cisco UCS C250 M2 Extended-Memory Rack-Mount
CONFIGURATION CONCEPTS SUN SPARC ENTERPRISE M-SERIES SERVERS. James Hsieh, Sun Systems Group. Sun BluePrints Online
SUN SPARC ENTERPRISE M-SERIES SERVERS CONFIGURATION CONCEPTS James Hsieh, Sun Systems Group Sun BluePrints Online Part No 820-7132-10 Revision 1.0, 12/17/08 Sun Microsystems, Inc. Table of Contents Introduction........................................................1
NEC Express5800/R120f-2M System Configuration Guide
NEC Express5800/R120f-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and
Intel Xeon Processor 5500 Series. An Intelligent Approach to IT Challenges
Intel Xeon Processor 5500 Series An Intelligent Approach to IT Challenges A Giant Leap for IT and Business Capabilities In many organizations, IT infrastructure has begun to constrain business efficiency
Cisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
Data Sheet Fujitsu PRIMERGY BX922 S2 Dual-Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX922 S2 Dual-Socket Server Blade Future-oriented Server Blade with all the prerequisites for virtualization environments The PRIMERGY BX Blade Servers are the ideal choice
Fujitsu PRIMERGY BX920 S2 Dual-Socket Server
Datasheet Fujitsu PRIMERGY BX920 S2 Dual-Socket Server Blade Datasheet for Red Hat certification Universal Dual-Sockel Server Blade with high computing and I/O performance in a small form factor The PRIMERGY
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
Cisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
Cisco UCS B-Series M2 Blade Servers
Cisco UCS B-Series M2 Blade Servers Cisco Unified Computing System Overview The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and
Oracle Database Reliability, Performance and scalability on Intel Xeon platforms Mitch Shults, Intel Corporation October 2011
Oracle Database Reliability, Performance and scalability on Intel platforms Mitch Shults, Intel Corporation October 2011 1 Intel Processor E7-8800/4800/2800 Product Families Up to 10 s and 20 Threads 30MB
Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis
White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document
HUAWEI E9000 Converged Infrastructure Blade Server
HUAWEI E9000 Converged Infrastructure Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The E9000 is a new-generation blade server that integrates computing, storage, switching,
Cisco UCS C24 M3 Server
Data Sheet Cisco UCS C24 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Table Of Contents. Page 2 of 26. *Other brands and names may be claimed as property of others.
Technical White Paper Revision 1.1 4/28/10 Subject: Optimizing Memory Configurations for the Intel Xeon processor 5500 & 5600 series Author: Scott Huck; Intel DCG Competitive Architect Target Audience:
SUN SERVER X3-2 SYSTEM
SUN SERVER X3-2 SYSTEM KEY FEATURES Compact and energy-efficient 1U enterprise-class server for mission-critical business workloads Intel Xeon processor E5-2600 product family CPUs Sixteen dual inline
HPC Update: Engagement Model
HPC Update: Engagement Model MIKE VILDIBILL Director, Strategic Engagements Sun Microsystems [email protected] Our Strategy Building a Comprehensive HPC Portfolio that Delivers Differentiated Customer Value
Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I
Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable
See BeYonD the LiMitS
SuN S full LINE of INTEGRATED SERVERS, SToRAGE, AND NETWoRKING SYSTEMS See BeYonD the LiMitS Highlights Sun offers a complete portfolio of products that converge servers, storage, software, and networking
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS)
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters from One Stop Systems (OSS) PCIe Over Cable PCIe provides greater performance 8 7 6 5 GBytes/s 4
How System Settings Impact PCIe SSD Performance
How System Settings Impact PCIe SSD Performance Suzanne Ferreira R&D Engineer Micron Technology, Inc. July, 2012 As solid state drives (SSDs) continue to gain ground in the enterprise server and storage
Copyright 2013, Oracle and/or its affiliates. All rights reserved.
1 Oracle SPARC Server for Enterprise Computing Dr. Heiner Bauch Senior Account Architect 19. April 2013 2 The following is intended to outline our general product direction. It is intended for information
HP Cloudline Overview
HP Cloudline Overview Infrastructure for Cloud Service Providers Dave Peterson Hewlett-Packard Company Copyright 2015 2012 Hewlett-Packard Development Company, L.P. The information contained herein is
Cisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
UCS M-Series Modular Servers
UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend
System Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced energy efficiency The PRIMERGY CX400 Cloud extension servers are Fujitsu
How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
Acer AT350 F1 specifications
Product overview The Acer AT350 F1 is a dual-socket tower or 4U rack mountable server for flexible environment delivering blazing performance and exceptional expansion capability. Offering high reliability,
Personal Systems Reference Lenovo ThinkServer Servers
Personal Systems Reference Lenovo ThinkServer Servers March 2011 - Version 396 New Lenovo ThinkServer 200 Series Family TS200v/TD230/RD240 Visit www.lenovo.com/psref for the latest version Lenovo ThinkServer
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.19 MAY 29, 2015 WWW.CISCO.COM
SUN ORACLE EXADATA STORAGE SERVER
SUN ORACLE EXADATA STORAGE SERVER KEY FEATURES AND BENEFITS FEATURES 12 x 3.5 inch SAS or SATA disks 384 GB of Exadata Smart Flash Cache 2 Intel 2.53 Ghz quad-core processors 24 GB memory Dual InfiniBand
SUN STORAGE F5100 FLASH ARRAY
SUN STORAGE F5100 FLASH ARRAY KEY FEATURES ACCELERATING DATABASE PERFORMANCE WITH THE WORLD S FASTEST SOLID- STATE FLASH ARRAY Unprecedented performance, power, and space efficiency World s first flash
An Oracle White Paper
An Oracle White Paper Oracle Server X5-2L System Architecture Introduction... 2 Product Overview... 2 Best for Oracle Software... 2 Oracle Solaris and ZFS Acceleration with Flash... 3 Oracle-Unique NVMe
PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation
PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS
APACHE HADOOP PLATFORM BIG DATA HARDWARE INFRASTRUCTURE SOLUTIONS 1 BIG DATA. BIG CHALLENGES. BIG OPPORTUNITY. How do you manage the VOLUME, VELOCITY & VARIABILITY of complex data streams in order to find
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with Internal PCIe SSD Storage
Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with This Dell Technical White Paper discusses the OLTP performance benefit achieved on a SQL Server database using a
NEC EXPRESS5800/R320c-E4 Configuration Guide
NEC EXPRESS5800/R320c-E4 Configuration Guide VMware model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure
Optimized dual-use server and high-end workstation performance
Optimized dual-use server and high-end workstation performance The ATX-sized(EEB mounting hole locations) Z9PA-U8 supports the latest Intel Xeon processor E5-2600 and E5-1600 product family, featuring
Boost Database Performance with the Cisco UCS Storage Accelerator
Boost Database Performance with the Cisco UCS Storage Accelerator Performance Brief February 213 Highlights Industry-leading Performance and Scalability Offloading full or partial database structures to
Power and Cooling Innovations in Dell PowerEdge Servers
Power and Cooling Innovations in Dell PowerEdge Servers This technical white paper describes the Dell Energy Smart Architecture and the new and enhanced features designed into Dell PowerEdge 12 th generation
How To Use Poweredge R520 (Poweredge) With Poweredge (Power Edge) And Poweredge V2 (Powertower) (Powerenerge) (Dell) (For A Poweredge) (Windows) (Amd) (
PowerEdge R520 Technical Guide The Dell PowerEdge R520 2-socket, 2U rack server delivers balanced performance and storage expandability for data-intensive applications. This document is for informational
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220
MESOS CB220 Cluster-in-a-Box Network Storage Appliance A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 A Simple and Smart Way to Converged Storage Tailored for SMB storage
Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U
Twin Servers Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U New Generation TwinPro Systems SAS 3.0 (12Gbps) Up to 12 HDDs/Node FDR(56Gbps)/QDR InfiniBand 1TB DDR3 up to 1866 MHz in 16 DIMMs Redundant
New levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U
New levels of efficiency and optimized design As always, ASUS makes servers that deliver superior performance. In this generation, the ASUS RS300-E8-RS4 supports the latest Intel Xeon E3-1200 v3 processor
1. Specifiers may alternately wish to include this specification in the following sections:
GUIDE SPECIFICATION Seneca is a leading US designer and manufacturer of xvault security and surveillance solutions. The xvault product line combines our IP expertise and solution partnerships with certified
SAS Business Analytics. Base SAS for SAS 9.2
Performance & Scalability of SAS Business Analytics on an NEC Express5800/A1080a (Intel Xeon 7500 series-based Platform) using Red Hat Enterprise Linux 5 SAS Business Analytics Base SAS for SAS 9.2 Red
HUAWEI E9000 Converged Infrastructure Blade Server
HUAWEI E9000 Converged Infrastructure Blade Server HUAWEI TECHNOLOGIES CO., LTD. The E9000 is a new-generation blade server that integrates computing, storage, switching, and management subsystems to form