Aspirating Smoke Detectors 420 Series Special environments require very early detection



Similar documents
Local SecurityNetwork We know what it s all about

Smoke detector 500 Series The art of invisible fire detection

Premium fire protection for a luxury-class hotel. "Kempinski Hotel The Dome" in Turkey installs a complete fire alarm system from Bosch.

Guarded community solutions Easy Series for villa and apartment projects

System off. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

FAAST. Fire Alarm Aspiration Sensing Technology

System off. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Fire detection equipment

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork

The Modular Alarm Platform 5000 A security system can be this flexible today and in the future

Yaşamları kurtarır, Değerlerinizi korur, İş süreçlerini güvence altına alır. Saving lives, protecting valuables, securing process cycles

Analogue addressable devices

HART HSSD High Sensitivity Smoke Detection

Buys Time. Air Sampling Smoke Detection

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

MINERVA MX MX Virtual Multi-Sensor Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Fire Detection Systems

FIRE DETECTION AND ALARM SYSTEMS

SPECIAL APPLICATIONS

Fire Alarm system Installation Guide

E-PDD Duct Smoke Detector Installation Sheet

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

SECTION DETECTION AND ALARM

EVALUATION OF THE PERFORMANCE OF FIRE DETECTION SYSTEM IN AN INSTITUTIONAL BUILDING

Solution Ultima ICP-CC488 Home security you can rely on

AlarmSense 2-wire detection and alarm system. Product Guide

radio fire alarm system Installed with minimum disruption Provides maximum protection

Flexible Aspirating Smoke Detection

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

Relative Sensitivity based Fire Detection Systems used in High Density Computer Rooms with In-Row Air Conditioning Units

Conventional Fire Detection and Extinguishant Control System Specification

All tested. Easy Series Intrusion Control Panel Making security easy featuring RADION wireless peripherals

How To Make A Commercial Detector

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Maximum uptime and optimum fire safety for your data center

D287/D288/D292/D293A/D293E

Building Integration System Your platform for customized security and safety management

720r Addendum: Siting the 720r

Building Integration System Your platform for customized security and safety management

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Using your LED Plus keypad

NX-10-V3 wireless system. To wire or not to wire?

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Voice alarm system E100 the new standard for safe evacuation

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

The World's No. 1 Brand of Air-sampling Smoke Detector

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Overview of Fire Alarm Systems and Maintenance

JAWAHARLAL NEHRU UNIVERSITY

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

CalMod Design-Build Electrification Services

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Product Information Fire alarm panel 8000 C

CBD-233. Fire Alarm and Detection Systems

Scalability is the best solution. The new Social Alarm Management System 7 Professional.

Maximum uptime and optimum fire safety for your data center

Perimeter Security System

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

COMITÉ EUROPÉEN DES ASSURANCES

Fire protection in archives and storage vaults

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Empirical Validation of Detection Systems Equivalency for Coincidence Suppression Actuation

INTREPID Perimeter Intrusion Detection System

Solution Ultima ICP-CC488 Home security you can rely on

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW

Expansion Modules & Accessories

wireless alarm system reliable protection for small-size buildings

Professional fire alarm panel for small and medium-sized objects. Compact

The supplier and installer of the system should be approved by the local civil defence authority.

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

I.S :2013 Fire Detection & Alarm Systems

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FSD Circular Letter No. 7/95 Automatic Fire Detection System - Design and Maintenance Considerations

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

Protection for everything you ve worked so hard to build.

DATA CENTER FIRE PROTECTION

I.S :2013 Fire Detection & Alarm Systems

Keys to understanding your alarm system

nr 28 nr 68 nr 4 nr 1

Flame detection across the spectrum. Range Brochure

SMART SENSOR COLLECTION

How can I protect valuable assets from fire and ensure business continuity?

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Product and Application Description

Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution

Transcription:

Aspirating Smoke Detectors 420 Series Special environments require very early detection

2 Aspirating Smoke Detectors: A sure-fire investment Actively protect your investments with a smoke aspiration system from Bosch Investing in a fire alarm system is the most effective way to safeguard your company. Protect your company, your employees and your assets with technology from Bosch. The solution to an underestimated problem Statistics show that in some countries, a fire breaks out every two seconds. The consequences can be devastating - and even being well-insured is of little help. The only solution is to detect fires as early as possible so action can be taken before they spread and cause damage. Conventional alarms aren t triggered until the fire has begun smoldering or even broken out into open flame. At that stage, fighting it can be difficult. This is the big advantage of smoke aspiration systems: they detect incipient fires and provide very early warning. Smoke density Detection range without smoke aspiration system Detection range smoke aspiration system Time Pyrolysis phase Smoke barely perceptible to humans Smoldering phase Smoke spreads slowly Open fire Smoke and heat spread excessively Early warning of fires with smoke aspiration systems How smoke aspiration systems work Smoke aspiration systems are modular, which makes it easy to tailor them to individual building conditions and potential fire risks. The two main components are: sampling pipes in the monitored area and a detector unit that can be located elsewhere. The detector generates a vacuum in the sampling pipes to ensure continuous air intake from the monitored areas. These actively obtained air samples are channeled through a sensitive optical sensor in a detection chamber to check for smoke particles. An intelligent signal processor then analyzes the measured data and decides whether there are any typical fire patterns. Evirnonmental effects that might cause false alarms are suppressed.

3 The advantages of smoke aspiration systems Highly reliable detection for early warning: Fires are detected when they are just beginning (in the pyrolysis phase). Highly sensitive sensors detect the presence of a fire before visible smoke is released, thus reliably preventing major damage in most cases. Minimization of false alarms: In smoke aspiration systems, intelligent signal processing largely suppress environmental factors that typically cause false alarms, such as dust, drafts and electrical interference. This enables higher sensitivity and ensures reliable operation even in challenging situations with high ceilings, extreme temperatures, dirt or moisture. Flexible placement and maintenance: The detection units can also be installed externally for monitoring double floors and cable conduits, so maintenance personnel can easily access them. Smoke aspiration systems can be unobtrusively integrated into buildings. System description Pipe system Patented aspiration reducing sheets with graduated hole diameters Air samples are continually drawn in from protected areas via defined sampling points. Detection unit State-of-the-art detector technology Reliable and extremely early warning with smoke sensitivities as fine as 0.05% Intelligent signal processing ensures highly reliable fire detection Innovative air flow sensors Monitoring of the pipe system for breakage and obstruction Settable to single-hole monitoring Robust, self-cleaning sensors

4 Technological highlights for reliable detection 1 Extremely high sensitivity with High-Power Light Source (HPLS) 2 A high-power light source makes the detection modules much more sensitive than common point type detectors. The air is led through a special measurement chamber that was specially developed for applications of this kind. High-power light source 1 Guided air stream to prevent deposition of particles 2 Light source (sender) 3 Photodiode (receiver) 3 In the detection chamber, extremely sensitive sensors provide very early warning to ensure enough time to extinguish a fire or take other action as required. The light source has a favorable spectrum to ensure consistent responses to all types of fires. Fire localization with ROOM-IDENT ROOM-IDENT enables both very early detection and localization of fires. A single detection unit can monitor up to five rooms. ROOM-IDENT tracks down the fire source in four phases, displaying the result both on the unit and in the affected room (optional). Phase 1 Phase 1 (normal mode): The pipes running accross to various rooms are used to obtain and evaluate air samples. 10 9 8 7 6 5 4 3 2 1 Phase 2 (very early fire detection): Any smoke is suctioned in and evaluated. The presence of smoke immediately triggers an alarm to enable an early response. Phase 2 Phase 3 (back flush): The intake fan is switched off when an alarm is given, and a second fan switches on to blow all smoke particles out of the pipes in the reverse direction. Phase 3 D C B Phase 4 5 4 3 2 1 Phase 4 (localization): After the pipe system is blown free, the direction of air flow is reversed again. Based on the amount of time that aspirated smoke takes to reach the detection module, the system determines which of the monitored rooms contains the fire.

5 The intelligent pipe system The air flow is constantly and intelligently monitored for breakage and obstruction. The sensitivity can be freely set, all the way to singlehole monitoring. This function is also temperature-compensated and can be programmed to take atmospheric pressure into account. 1 2 3 1 2 4 Example pipe layouts for use of one detector module 1 I configuration 2 U configuration 3 M configuration 4 Double-U configuration Example pipe layouts for a two-detector setup 1 Room protection 2 Protection of facilities or small rooms 2.0 2.0 Aspiration-reducing film Graduated aspiration-reducing sheets achieve balanced air samples across all sampling points and prevent annoying whistling (scale of drawing 1:1). Accessories (selection) Freezer clips Manual and automatic blow-out devices to eliminate ice and dust Detonation fuse for areas with risk of explosions Filters for extremely dusty areas Steam trap Local SecurityNetwork functionality The aspirating smoke detectors of the 420 series work with Bosch s Local SecurityNetwork (LSN) bus system. LSN is a freely configurable security bus system that offers a wide choice of fire, intrusion and malfunction detectors, operator units and aiming devices from multiple manufacturers. The bus uses the master-slave principle, with all smoke detectors, remote indicators, fire alarm devices, intrusion detectors, keypads, arming devices and sounders connected to it. The network can be flexibly structured with loop, stub or tee-off configurations; the possibilities are additionally extended by interfaces with inputs and outputs and zone expanders. Power and data are transmitted over two wires. A wide range of LSN components is available, including over 70 different sensors from six manufacturers and various panel types from eight manufacturers. The system complies with EN 54, EN 50131 Grade 4 and VdS Class C. LSN improved technology and modules accommodate currents up to 1500 ma over up to 3000 meters. The voltage on the LSN bus is 30 V at the bus driver module.

6 FAS-420-TM Series This affordable, compact solution is ideal for protecting areas of up to 400 square meters, even under challenging environment conditions. This affordable, compact solution individually monitors up to five rooms including small ones and determines the locations of any detected fires. Featuring innovative air flow sensors, it supports up to eight aspiration openings with a single 40-meter pipe or two 25-meter pipes. It is suitable for areas as large as 400 square meters; the possible applications include hotel rooms, small server rooms, small high-rise warehouses, etc.

7 FAS-420-TP Series This universal solution can be configured so that two detectors must confirm a fire before an alarm is triggered (two-detector dependency). Although, the use of only one detector is also possible. Up to 48 aspiration openings are supported per system, with a maximum pipe length of 360 meters. The system can be optionally networked. The applications include production plants, clean rooms and large server rooms, depending on the size of the area requiring protection.

8 FAS-420-TT Series This universal solution features a 10-stage alarm display with up to three alarm levels (information, pre-alarm, main alarm). It also provides a ten-digit bar graph for monitoring smoke pollution (also available in a MicroSens version). Two modules can be deployed to double the surveyed area; they can also be linked to that two detectors must confirm a fire before an alarm is triggered. Up to 48 aspiration openings are supported per system, with a maximum pipe length of 360 meters. The range of applications includes manufacturing facilities, clean rooms and large server rooms.

9 Product features TM TP TT Suitable for use under difficult conditions Practical installation tools VdS and EN 54-certified Suitable for deep-freeze applications Up to three alarm levels, with pre-alarm and main alarm Intelligent signal processing Sensitivity settable to 0.05%/m of light obscuration for main alarm Display sensitivity down to 0.005%/m of light obscuration 10-level alarm display for smoke density Two-zone dependency Two-detector dependency Up to 48 aspiration openings per system, max. pipe length 360 meters ROOM-IDENT Extensive range of accessories Innovative air flow sensor technology Relay contacts connectable with the fire alarm system via plug & play Infrared diagnosis tool

10 A wide range of applications Thanks to their outstanding features, the smoke aspiration systems from Bosch can be used almost anywhere. Their many applications include clean rooms, high-rise warehouses, factories, conveyor belts, paper mills, recycling plants, data centers, false floors, cable conduits, switch cabinets, telecommunications equipment, high-voltage facilities, EMC testing areas, glazed buildings, elevator shafts, escalators, car parks, modern and historic buildings, libraries, saunas, hotel rooms and prison cells. The 420 Series smoke aspiration systems can also be customized. Just talk to us! Example 1: High-rise warehouse The pipe system is easy to integrate into the warehouse design. Active air sampling over the entire height ensures early detection. The system s parts are easy to access, which reduces maintenance and servicing costs. Regular operations can continue while maintenance is being done. Example 2: Factory The pipe system is easy to install in a production building s supporting elements. This ensures reliable detection in areas with high levels of dust and contamination. The detector unit is installed at eye level. Maintenance and servicing are straightforward, also in high buildings and when there are complex ceiling conveyors.

11 Example 3: Library The system s highly sensitive detection technology with a high-power light source (HPLS) ensures extremely early warning of fire to protect archived books and documents. The pipes can be installed right on the shelves. A multistage alarm approach can be implemented to protect irreplaceable items. Anything is possible 420 Series aspirating smoke detectors from Bosch meet the highest standards in terms of safety, reliability and flexibility. Their highly sensitive sensors detect fire at the earliest possible stage. Intelligent signal processing efficiently eliminates extraneous factors that could otherwise trigger a false alarm. These systems also save you time and money for maintenance and servicing.

A Tradition of Quality and Innovation For over 100 years, the Bosch name has stood for quality and reliability. Bosch is the global supplier of choice for innovative technology, backed by the highest standards for service and support. Bosch Security Systems proudly offers a wide range of security, safety, communications and sound solutions that are relied upon every day in applications around the world, from government facilities and public venues to businesses, schools and homes. Bosch Security Systems To learn more about our product offering, please visit www.boschsecurity.com or send an e-mail to emea.securitysystems@bosch.com Bosch Sicherheitssysteme GmbH, 2008 Modifications reserved Printed in Germany 09/08 Printer FS-OT-en-01_4998144264_09