Control and Indicating Equipment



Similar documents
Additional Requirements

Conventional Fire Detection and Extinguishant Control System Specification

VdS 5473en : (01) Video Surveillance Systems (CCTV)

Metal Pressfitting Pipe Systems

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

BS 7 SIS Safety Information System Green Light for Your Production

ABUS WIRELESS ALARM SYSTEM

Panel Controller MPC-xxxx-B FPA-1200-MPC. Operation guide

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

VdS Guidelines for the Certification of quality management systems

Notes on the certification and surveillance of management systems for companies with subsidiaries

Fax: Telephone Number of your Alarm System. Get the list of commands sent to your phone

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Invitation to Bid FIRE ALARM & DETECTION SYSTEM

ICP-CP500. User's Guide ICP-CP500 Codepads

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

How To Comply With The Loss Prevention Certification Board

COMITÉ EUROPÉEN DES ASSURANCES

SECON-X. Technical Documentation. SECON-Vap user manual. Version: 1 Edition: Article no.:

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

VR8. User Guide Intruder Alarm System

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network

CONSOLIDATED VERSION IEC Medical device software Software life cycle processes. colour inside. Edition

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression Systems

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Risk Engineering Guideline

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

AMAX 2100 / 3000 / en User Guide

BS5839 Part 1:2002 Overview

C e r t i f i c a t e of Conformity

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

500r+ Installation and User Guide

9452/9453 Installation and User Guide

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

How To Set A Timer On A Gg System

COMITÉ EUROPÉEN DES ASSURANCES

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

VEGA Analogue Addressable Control Panels

Advanced Intelligent Modules. Overview. Description

C e r t i f i c a t e

Overview of Fire Alarm Systems and Maintenance

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

astec Integrated Alarm System USER GUIDE

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

IGNIS 1240 FIRE DETECTION AND ALARM CONTROL PANEL

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

Information Bulletin. Sprinkler System Component Fault Monitoring. Version 1.1 Approved for release September 2013

ViZion Installation Guide

Compliance Schedules and Building Warrant of Fitness

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS

WIRELESS MAGNETIC CONTACT

INTERNATIONAL TELECOMMUNICATION UNION

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

Shunt lock function 3066 Operator Instructions

Product Information Fire alarm panel 8000 C

System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork

MINIMUM TECHNICAL AND EXPLOITATION REQUIREMENTS FOR DIGITAL SOUND BROADCASTING DAB+ RECEIVER DESIGNED FOR POLAND

How can I protect valuable assets from fire and ensure business continuity?

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

S4000TH HART. HART Communication Manual

Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals

AlarmSense 2-wire detection and alarm system. Product Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

NetworX NX-6V2. LED Keypad User Manual

conventional system operation

Manual for Fire Suppression & Methane Detection System

NATIONAL FIRE ALARM AND SIGNALING CODE

INFORMATION ON STANDARDS FOR ELECTRONIC SECURITY SYSTEMS

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

SECURITY SYSTEM NOTES

Begin using tomorrow s security features today.

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

PRODUCT CATALOGUE.

Greater Manchester Fire and Rescue Service

Guidance for accreditation of EN 15224:2012 Health care services Quality management systems Requirements based on EN ISO 9001:2008

FIRE DETECTION SYSTEMS ALARM STRATEGIES 2.0. New Version

ICP-CC488. Installation Guide ICP-CC488 Control Panel

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU Rev 1

Electronic Power Control

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

ACTIVE 5 ENGINEERING MANUAL

WIND TURBINE DAMAGE PREVENTION 2014

Safety signs and symbols

Quality Management of Software and Systems: DIN ISO 9000-Standards

Iphone & Android App Smart GSM Home Alarm System

DESTINY 1/19/96 # A

fulfils all requirements for extended protection of the criteria catalogue The appendix is part of the certificate and consists of 4 pages.

Transcription:

VdS Guidelines for Fire Detection and Fire Alarm Systems VdS 2540en Control and Indicating Equipment Requirements and Test Methods VdS 2540en : 2010-12 (02)

Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln, Germany Phone: +49 221 77 66 0; Fax: +49 221 77 66 341 Copyright by VdS Schadenverhütung GmbH. All rights reserved.

VdS 2540en : 2010-12 (02) Fire Detection and Fire Alarm Systems, Control and Indicating Equipment VdS Guidelines for Fire Detection and Fire Alarm Systems Control and Indicating Equipment Requirements and Test Methods Contents 1 General... 4 1.1 Scope... 4 1.2 Validity... 4 2 Normative references... 4 3 Definitions... 4 4 Requirements and test methods... 5 4.1 General... 5 4.2 Requirements and test methods of DIN EN 54-2... 5 4.3 Additional functions... 7 3

Fire Detection and Fire Alarm Systems, Control and Indicating Equipment VdS 2540en : 2010-12 (02) 1 General Tests in accordance with these Guidelines shall be carried out by a testing body accredited in accordance with DIN EN ISO/IEC 17025. 1.1 Scope These Guidelines specify requirements, test methods and performance characteristics for control and indicating equipment for the use in automatic fire detection and fire alarm systems installed in buildings, applicable in accordance with the relevant Guidelines for planning and installation VdS 2095. These Guidelines are relevant in addition to European standard EN 54-2 harmonised in accordance with the Construction Products Directive of the European Union. They are mandatory only if their application is agreed on an individual basis. Otherwise they are not binding; an agreement on the application of these Guidelines is purely optional. 1.2 Validity These Guidelines are valid as of their date of publishing. 2 Normative references These Guidelines incorporate, by dated or undated references, provisions from other publications (e.g. European standards EN), as specified below. For dated references to other publications amendments to or revisions of any of these publications apply to these Guidelines only when incorporated in them by amendment or revision. For undated references the latest edition of the publication referred to applies. DIN EN 54-1 Fire detection and fire alarm systems Part 1 : Introduction DIN EN 54-2 Fire detection and fire alarm systems Part 2 : Control and indicating equipment DIN 14675 Fire detection and fire alarm systems Configuration and operation DIN 14661 Firefighting equipment Fire brigade control panel for fire detection and fire alarm systems DIN 14662 Firefighting equipment Fire brigade indicator panel for fire detection and fire alarm systems VdS 2496 Triggering of fire extinguishing systems 3 Definitions For an application of these Guidelines the definitions specified in the a.m. regulations apply. 4

VdS 2540en : 2010-12 (02) Fire Detection and Fire Alarm Systems, Control and Indicating Equipment 4 Requirements and test methods For compliance with these Guidelines, control and indicating equipment shall fulfil the following requirements: the relevant requirements of product standard DIN EN 54-2; and the requirements of these Guidelines. 4.1 General The general test and connection conditions of DIN EN 54-2 apply. 4.2 Requirements and test methods of DIN EN 54-2 4.2.1 Requirements On principle, the requirements of DIN EN 54-2 apply. In addition, the following options with requirements of DIN EN 54-2 shall be implemented as specified below: Option with requirements of DIN EN 54-2 DIN EN 54-2, Cl. Option Note Controls: Delays to outputs Output C 7.11.1 may be provided Output E 7.11.1 may be provided Output G 7.11.1 not permitted Provision to switch on/off delays 7.11.2 shall be provided Dependencies on more than one alarm signal Type A dependency 7.12.1 may be provided Type B dependency 7.12.2 Confirmation alarm signal from the same fire detector may be provided Confirmation alarm signal from another fire detector in the shall be provided same zone Confirmation alarm signal from another fire detector in another may be provided zone Type C dependency 7.12.3 not permitted Disablement of addressable points 9.5 may be provided Test condition 10 shall be provided 2) 2) 1) 1), 2) 2), 3) 2), 3) 5

Fire Detection and Fire Alarm Systems, Control and Indicating Equipment VdS 2540en : 2010-12 (02) Option with requirements of DIN EN 54-2 DIN EN 54-2, Cl. Option Note Inputs/Outputs: Output to fire alarm devices 7.8 shall be provided Control of fire alarm routing equipment Output to fire alarm routing equipment Alarm confirmation input from fire alarm routing equipment Outputs to fire protection equipment 7.9.1 shall be provided 7.9.2 shall be provided Output type A 7.10.1 may be provided Output type B 7.10.2 may be provided Output type C 7.10.3 shall be provided Fault monitoring of fire protection equipment 7.10.4 shall be provided Output to fault warning routing equipment 8.9 shall be provided Standardised input/output interface 11 may be provided Indications: Alarm counter 7.13 shall be provided Fault signals from points 8.3 may be provided Total loss of the power supply 8.4 may be provided 4) 4) 4) 4) Notes: 1) strictly not permitted for the triggering of fire extinguishing systems in accordance with VdS 2496 2) not permitted in combination with a manual call point 3) A confirmation alarm signal from another fire detector in another zone shall be required, if a confirmation signal from another fire detector in the same zone is technically impossible. 4) The interfaces for the triggering of fire alarm routing equipment and of control and alarm devices not incorporated in the fire detection system shall comply with DIN 14675 Annex B, Table B.1. These requirements do not apply to interfaces for the triggering of fixed fire extinguishing systems. 4.2.2 Test methods Testing for compliance with the requirements specified in 4.2.1 of DIN EN 54-2, Cl. 4 to 14 by visual inspections and functional tests and check of the documentation. DIN EN 54-2, Cl. 15, Test for environmental stability as specified. Exception: In the test according to DIN EN 54-2, Cl. 15.8.1 d) Radiated electromagnetic fields the field strength is increased to 30 V/m in the range (890-960) MHz at increments of 3 MHz. Testing of inputs/outputs acc. DIN EN 54-2, Cl. 7.8, 7.9, 7.10 and testing of interfaces for compliance with the requirements of DIN 14675 Annex B, Table B.1. 6

VdS 2540en : 2010-12 (02) Fire Detection and Fire Alarm Systems, Control and Indicating Equipment 4.3 Additional functions 4.3.1 Triggering of fire extinguishing systems On principle, the control and indicating equipment shall have provision for a standardised interface for extinguishing systems in accordance with VdS 2496 for the triggering of fire extinguishing systems. Note 1: The standardised interface for extinguishing systems may be omitted, provided that the fire detection and fire extinguishing systems are tested as one system and their compatibility is thus verified. Note 2: The standardised interface for extinguishing systems may comprise an output in accordance with 7.10.3 and an input in accordance with 7.10.4 of DIN EN 54-2. 4.3.1.1 Requirements Designation of terminals in the control and indicating equipment The terminals of the interface for the triggering of an extinguishing system in or at the control and indicating equipment shall be marked Extinguishing System. Indications The indications for Extinguishing System released and Fault Extinguishing System shall be by means of separate light emitting indicators and/or an alphanumeric display. At least one common indication each for Extinguishing System Released and Fault Extinguishing System is required; they shall not be suppressed during the fire alarm condition. It shall be possible to interrogate suppressed indications for Extinguishing System Released and Fault Extinguishing System at access level 1. 7

Fire Detection and Fire Alarm Systems, Control and Indicating Equipment VdS 2540en : 2010-12 (02) The indications for Transmission Path Fault shall be by means of separate light emitting indicators and/or an alphanumeric display. These indications may be suppressed during the fire alarm condition. The indications Transmission Path Fault and Fault Extinguishing System shall be yellow. The indication Extinguishing System Released shall be red. For alphanumeric displays no colour differentiation of the indications is required. 4.3.1.2 Test method Testing for compliance with the requirements of 4.3.1.1 with regard to connection, function and indications by functional test and visual inspection. 4.3.2 Fire brigade control panel 4.3.2.1 Requirements The control and indicating equipment shall have provision for an interface in accordance with DIN 14675 Annex D for the connection of a fire brigade control panel in accordance with DIN 14661. 4.3.2.2 Test method Testing of the interface for compliance with the requirements of DIN 14675 Annex D by measurement of the parameters and functional test, and testing for compliance with the required indicating and control functions specified in DIN 14661 in interaction with the control and indicating equipment by functional test and visual inspection. 4.3.3 Fire brigade indicator panel 4.3.3.1 Requirements If a fire brigade indicator panel is to be connected to the control and indicating equipment, the control and indicating equipment shall have provision for an interface for the connection of a fire brigade indicator panel in accordance with DIN 14662. 4.3.3.2 Test method Testing for compliance with the indicating and control functions specified in DIN 14662 in interaction with the control and indicating equipment by functional test and visual inspection. 8

VdS 2540en : 2010-12 (02) Fire Detection and Fire Alarm Systems, Control and Indicating Equipment 9

10 Fire Detection and Fire Alarm Systems, Control and Indicating Equipment VdS 2540en : 2010-12 (02)