AlarmLine Addressable Linear Heat Detector



Similar documents
Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

ALARMLINE ANALOGUE Linear Heat Detection System

LHD LINEAR HEAT D ETECTIONN

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Intersection Preassembled 19-inch Rack

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Advantium 2 Plus Alarm

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Fire Alarm System Accessories

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Instrumentation Cable Power Cable Assembly Solutions...32

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Generator DoCKInG StatIonS

Standard Buccaneer - Ethernet

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ACS-30-EU-EMDR-10-MOD

Color Mark Sensor with Red or Green LED E3S-VS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

TrueAlarm Fire Alarm Systems

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

289 SERIES FLOW METER TRANSMITTERS

400 Series - Mini USB Buccaneer

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Interface Level And Point Level Analyzers & Sensors

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

NGC-30-CR -CRM -CRMS -CTM -CVM

Passive Infrared Motion Detector 5420/90. Installation Instructions

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

DTW Works Master Specification Version 2006

DuroSite TM High Bay Lighting

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Distributed Temperature Sensing - DTS

Manual for Fire Suppression & Methane Detection System

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

RAY-MAX Integrated Solar Power Strip

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Fire Pump Controllers Remote Alarm Panels

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

DUCT SMOKE DETECTOR D4120

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Ethernet Cat 5e & Cat 6 Patch Panels

How To Read A Pipe From A Sensor

Triple Waveband Infra-Red Flame Detection

Standard Buccaneer - USB

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Fire detection equipment

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

SMART SENSOR COLLECTION

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

User s Manual Before using the inverter, you need to read and save the safety instructions.

INFRARED QUARTZ WALL HEATER

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

D287/D288/D292/D293A/D293E

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Fire & Security DETECTORS

Electronic Control Devices The European Product Catalogue 2007

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Problem / Solution. The problem:

Y7230A CO 2 Alarm System

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

E-PDD Duct Smoke Detector Installation Sheet

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Smoke Detector PSD 2 & 4 Wire Units

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

CITY OF LOS ANGELES CALIFORNIA

Emergency lighting units EM powerled

3DLevelScanner II TECHNICAL DATA SHEET

6000 Series Buccaneer

IEC Connectors. Introduction

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

How To Use A Ds340 (Dsp)

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Absolute Rotary Encoder E6CP

DuroSite TM Series LED High Bay. for Industrial & Commercial Applications.

LIEBERT VNSA Installation Sheet

HARTING Ethernet Cabling 4-poles Overview

Transcription:

Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting SmartOne addressable devices Up to 2 Addressable Line Modules (AAM) per addressable loop Real-time monitoring Software adjustable alarm set point Optional pre-alarm and overheat output configuration selections Three cable styles (standard, nylon, bronze braided) cable restorable up to 27 F Full supervision for short and open circuits Two-color status-led display for alarm and trouble conditions Intrinsically safe option Flexibility in zoning Enhanced response time DESCRIPTION The Line Addressable Linear Heat Detector provides early detection of fire or overheat condition in protected areas or equipment. It is especially suited for confined areas or environments where adverse ambient conditions cause other detection devices to be unreliable or difficult to use. The detector consists of two major components: A sensor cable and an Addressable Line Module (AAM). The AAM is used with any intelligent control panel that accepts SmartOne devices. APPLICATIONS Open-area protection Cable trays Rack storage Freezer warehouses Belt conveyers Floating roof fuel tanks Cooling towers Dust collectors Waste fuel drum storage Power distribution apparatus Escalators Tunnels Mines Hangars

BENEFITS Application Flexibility: Allows installation at point of risk. Programmable pre-alarm, alarm, and overheat levels for differing ambient conditions. Durability: Extrusion and braiding options to satisfy environmental conditions and project risks. Reliability: Fault signaling of open and short circuit conditions, pre-alarm, alarm, and overheat reporting. Recoverability: Cable does not need to be replaced after an alarm event as high as 27º F (12º C). Sensitivity: Proven superiority over point-type measurement. ANALOG HEAT SENSING Line s analog heat sensing characteristics offer several distinct advantages: Field Adjustability of pre-alarm, alarm, and overheat setpoints: Pre-alarm, alarm, and overheat thresholds may be programmed to meet specific system requirements. Integrating: It is not necessary to reduce sensor spacing with increased ceiling height per NFPA 72-2007 Section.6...1, Exception (1). System sensitivity remains constant as ceiling height increases without reducing spacing. Short Circuit Discrimination: The system will produce a trouble condition instead of a false alarm in the event of a conductor to conductor short due to damage or electrical faults. SENSOR CABLE The Line sensor cable consists of four 26 AWG copper conductors, each color-coded in an insulated sheath containing a negative temperature coefficient polymer (where an increase in temperature decreases the resistance of the sensor). Two of the conductors are enameled and provide loop continuity supervision, but not temperature sensing. The conductors are twisted at thirty turns per foot (90 turns per meter) and protected by a flame-retardant outer extrusion or metallic braid (See Figure 1). The color coding of the four inner conductors is repetitively marked on the outer coating every three feet as an aid installation. Cable is sold in standard coils of 66 feet (200 meters) and 280 ft. (00 m). Note: The maximum length of sensor cable per zone depends on the maximum ambient temperature defined on the nomogram(s) (See Figures 2 and ). Regardless of ambient temperature, however, the maximum length of cable is 280 feet (00 meters) per zone for Type T cable. CABLE SENSOR Figure 1. Standard Cable NEGATIVE TEMPERATURE COEFFICIENT MATERIAL SENSOR CONDUCTOR WIRE PROTECTIVE INSULATION HIGH TEMPERATURE PVC PART NUMBERS cable is available with the following part numbers: Standard Cable 7-117068-0 (66 ft./200 m) 7-117068-1 (280 ft./00 m) Recommended for environments ranging from clean and dry to moderate dust and moisture. Nylon Coated Cable 7-117068-016 (66 ft./200 m) 7-117068-116 (280 ft./00 m) Recommended for use in wet, oily, or corrosive environments or outdoors. Use in freezer warehouses. Phosphor Bronze Braided 7-117068-019 (66 ft./200 m) 7-117068-119 (280 ft./00 m) Recommended for applications requiring superior abrasion protection and/or increased tensile strength. ADDRESSABLE ALARMLINE MODULE (AAM) The AAM permits an Line sensor cable to be directly interfaced to any control panel that accepts SmartOne addressable loop devices. This interface will allow for pre-alarm, alarm, and trouble conditions to be transmitted to the control panel via the Signaling Line Circuit (SLC). The AAM monitors the resistance of the sensor cable and generates a pre-alarm (if enabled), alarm, or overheat output (if enabled) when the resistance drops below the programmed threshold. The module also supervises the Line cable for opens and shorts, which will generate a fault condition. All of the pre-alarm, alarm, overheat, and trouble conditions will be displayed on the control panel. Up to 2 AAM modules can be connected to a single SLC loop. Use of multiple AAMs allows flexibility in zoning larger installations for location of alarm and zone output control; the control panel acts as a central display and control interface. The AAM receives power directly from the SLC loop which eliminates the need for additional wiring and external power supplies. - 2 -

For further information on installation and configuration of the AAM, please refer to the Line Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-2820-00. The Addressable Line Module is available using the following part numbers: 7-0001-00 Module with operating temperature range of -40º Fº to º F (-40º C to 60º C). Mounted on a 4-inch square faceplate. AAM mounts in a 4-inch square backbox, 2-1/8-inches deep. Description Standard Service Life Up to 212ºF (0ºC) = 0 years @ 27ºF (12ºC) = 24 hours. Self Restores below 27ºF (12ºC) Above 74ºF (190ºC) is the destructive temperature. Nylon Coated Up to 212ºF (0ºC) = 0 years @ 27ºF (12ºC) = 24 hours. Self Restores below 27ºF (12ºC) Above 74ºF (190ºC) is the destructive temperature. Bronze Braided Up to 212ºF (0ºC) = 0 years @ 27ºF (12ºC) = 24 hours. Self Restores below 27ºF (12ºC) Above 74ºF (190ºC) is the destructive temperature. 7-000-001 NEMA-4 sealed, protective polycarbonate enclosure used to mount AAM in wet or dusty environments. Approved Spacing (between parallel runs) 0 ft. (9 m) 0 ft. (9 m) 0 ft. (9 m) CABLE SPECIFICATIONS Description Part Number : Length: Weight: Part Number : Length: Weight: Jacket Construction External Diameter Standard 7-117068-0 66 ft. (200 m) 7 lbs. (.2 kg) 7-117068-1 280 ft. (00 m) lbs. (14. kg) Blue PVC 0.117 in. ( mm) Nylon Coated 7-117068-016 66 ft. (200 m) 7 lbs. (.2 kg) 7-117068-116 280 ft. (00 m) lbs. (14. kg) Black nylon extrusion over blue PVC 0.1 in. (.9 mm) Bronze Braided 7-117068-019 66 ft. (200 m) 7 lbs. (.2 kg) 7-117068-119 280 ft. (00 m) lbs. (14. kg) Phosphor bronze braid over blue PVC 0.1 in. (.9 mm) SENSOR MOUNTING HARDWARE Three types of standard mounting hardware (master clamp, flange clamp, nylon cable tie) for Line permit safe, secure sensor cable installation in most applications. Other mounting means may be used as required by the specific application. The sensor should be supported at a minimum of ten foot intervals on straight runs when under tension, and more as conditions dictate at corners and transition points to provide suitable strain relief. Local codes or conditions may also require the sensor to be supported at closer intervals. Refer to the Line Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-2820-00 for specific mounting information. Tensile Strength 0 N 0 N 00N Insulation Costs 1 = Orange 2 = White = Red 4 = Blue 1 = Orange 2 = White = Red 4 = Blue 1 = Orange 2 = White = Red 4 = Blue Material 26 AWG Solid Copper 26 AWG Solid Copper 26 AWG Solid Copper Diameter 0.018 in. (0.460 mm) 0.018 in. (0.460 mm) 0.018 in. (0.460 mm) Twist of Inner s 0 per ft. (90 per m) 0 per ft. (90 per m) 0 per ft. (90 per m) Dielectric Material Specially Doped Polymer Specially Doped Polymer Specially Doped Polymer Standard Outer Jacket Material High Temperature PVC High Temperature PVC High Temperature PVC Voltage Proof Between PVC Jacket and a KV KV KV - -

AAM SPECIFICATIONS Specification Value Part Number 7-0001-00 Supply Voltage Current Consumption, Standby Current Consumption, Current Consumption,Fault Noise Performance LED Pulse Modes Operating Temperature Range P.C. Line, 16. to 27. Vdc 42 µamps 440 µamps 42 µamps Withstands % RMS 60 Hz supply noise or 1 Vrms 60 Hz sensor noise with negligible performance range. RFI immunity at V/meter field strength over the band of 20 to 900 MHz Normal: Slow flash GREEN every nine (9) seconds Pre-: Slow flash RED every nine (9) seconds : Fast flash RED every two (2) seconds Trouble: Off -40 F to F (-40 C to 60 C) INTRINSIC SAFETY BARRIERS In classified hazardous areas where potentially explosive vapors, dust, or fibers exist, Line cable must installed using an intrinsic safety barrier. The barrier (P/N 7-117068-01) is a shunt diode safety barrier which limits the current and voltage in the sensor cable to safe levels. Each barrier handles two conductors, so two barriers are needed for each sensor cable. The barriers are designed to mount in separate weathertight enclosures. The intrinsic safety barrier s specifications are as follows: UL Listed and FM Approvals Operating Temperature Range Class I, Division I, Groups A, B, C, D Class II, Division I, Groups E, F, G: Class III, Division I -4ºF (-20ºC) to ºF (60ºC) Humidity -% R.H. Terminals Will accept up to #12 AWG Working Voltage 6V Maximum Voltage 7.V Fuse Rating 0 ma Leakage Current 1 ma maximum at 6V End-To-End Resistance Enclosures 14 ohm maximum 90 ohm minimum 7-117068-72 holds 2 barriers 7-117068-7 holds barriers 7-117068-74 holds 12 barriers 7-117068-7 holds 24 barriers SETTING THE ALARM TEMPERATURE When determining the alarm temperature setting, the designer must take into account environmental factors that may affect the overall response of the system. By accounting for these factors, the designer minimizes unwanted alarms. Below is a step by step procedure which instructs the designer in selection of the proper alarm trip points. The required alarm temperature and the correct alarm configuration setting for the AAM are determined using the Line nomogram(s). Measurements are in feet/fahrenheit or meters/ centigrade. The use of the nomogram requires two known factors: Maximum ambient temperature of the alarm zone. (Scale A). The total length of the sensor cable to be used. (Scale L). The resistance change required to create an alarm can be a result of either a predetermined minimal increase in temperature over the entire length of the sensor, or a significant increase on a shorter section of cable. The alarm temperature in either case is determined only after the alarm trip switch position for the entire sensor length is known. A shorter section of sensor cable exposed to an overheat condition will require a higher temperature to achieve an alarm than a longer length of sensor cable exposed to the same overheat condition. The maximum length of sensor cable per zone depends on the maximum ambient temperature defined on the nomogram. Regardless of ambient, however, the maximum length of cable connected to a single AAM is 280 ft. (00 m). If cable length exceeds 280 ft., the - 4 -

alarm condition could be reached at room temperature (70º F (20º C)) for most switch settings. Refer to the Line Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-2820-00 for more information. KIDDE-FENWAL, INC. 400 MAIN ST. ASHLAND, MA 01721 ADDRESSABLE ALARMLINE MODULE CAT NO. 7-0001-00 FM PRODUCT MUST BE INSTALLED AND OPERATED APPROVED IN ACCORDANCE WITH KIDDE-FENWAL INSTALLATION MANUAL 7.04 AND JURISDICTION OF LOCALAUTHORITY. UR L S A T L Configuration Setting Maximum Ambient Specified Cable Length (Ft.) DATE OF MANUFACTURE: ALL TERMINALS ARE POWER LIMITED TB1 P.C. LINE A B A B 4 2 1 DEVICE ADDRESS # SENSOR CABLE BLU RED WHT ORN 4 2 1 TB2 1 2 4 6 7 8 9 11 12 14 1 16 7 8 10 17 18 1 10 17 18 1 20 2 220 20 240 20 27 200 2900 2600 200 2000 0 00 82 00 26 20 200 0 80 6 Figure 2. Example for Type T Cable (Feet/Fahrenheit) 1 2 4 6 7 8 9 11 12 14 1 16 S A T L Configuration Settng Maximum Ambient 7 8 10 17 18 1 Specified Figure. Example for Type T Cable (Feet/Fahrenheit) 10 17 18 1 20 2 220 20 240 20 27 Cable Length (Ft.) 200 2900 2600 200 2000 0 0 00 82 60 00 00 26 20 200 0 80 6 0 2 20 0 60 00 0 2 20 EARTH GROUND P.C.LINE OUT P.C.LINE IN WEATHERPROOF JUNCTION BOX (IF REQUIRED) BLUE RED WHITE ORANGE 4 2 1 4 2 1 Figure 4. Wiring the AAM to a Panel INTERCONNECT CABLE 16 AWG, 4 CONNECTOR (IF REQUIRED) SENSOR CABLE ADDRESSABLE ALARMLINE MODULE WIRING The Addressable Line Module (P/N 7-0001- 00) may connected to any fire control panel that accepts SmartOne addressable devices. The module is wired directly to the SLC loop of the panel as shown in Figure 4. Refer to the Line Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-2820-00 for complete wiring information. NEMA-4 ENCLOSURE The NEMA-4 polycarbonate enclosure (P/N 7-000- 001) is designed to mount the Addressable Line Module in areas requiring additional protection from wet and/or dusty environments. This enclosure is rated as follows: UL 08 Type 4, Type 4X, Type 6, Type 12, and Type NEMA Type 4, Type 4X, Type 6, Type 12, and Type CSA Type 4, Type 4X, Type 6, Type 12, and Type Flammability rating UL94-V IEC 29, IP66 The enclosure is equipped with a clear cover so that the AAM alarm/trouble status indicator LED can be viewed. The cover also provides a molded-in wire-lead hole for tamper resistant installation. Mounting holes for the enclosure are molded directly under the cover screws. A cover gasket assures watertight and dust-tight seals. - -

The impact-resistant, glass-filled, polycarbonate enclosure material is easily punched, drilled, or sawed to provide access for field wiring. For further installation information, refer to the Line Addressable Linear Heat Detector Installation, Operation, and Maintenance Manual, P/N 06-2820-00. 4.0 ENCLOSURE BRACKET 4.0 AAM COVER MOUNTING HOLE FOR #8 SCREW (TYP.) Line SELF-TAPPING SCREWS SmartOne TINNERMAN CLIPS #8-2 SCREWS Figure. NEMA-4 Enclosure with AAM CROSS-POINT, CAPTIVE COVER SCREWS This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (08) 881-2000. K-7-02 Rev BB 2008 Kidde-Fenwal Inc. Printed in USA KIDDE-FENWAL INC. 400 MAIN STREET, ASHLAND, MA 01721 TEL: (08) 881-2000 FAX: (08) 881-8920 www.kidde-fenwal.com