LIEBERT CORPORATION Air Products. Model Number Reference Guide. Revision: April 2004



Similar documents
Liebert DS Thermal Management Unit

In Row Cooling Options for High Density IT Applications

Liebert Deluxe System/3

Local Dealer:

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

MAC-120HE-01 Air-Cooled Chiller

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Liebert Mini-Mate2 1 & 1.5 Ton (3.5 & 5kW) Capacity

Defining Quality. Building Comfort. Precision. Air Conditioning

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Mechanical Rooftop Custom Capabilities

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Nordic Heat Pump Product Guide

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

york air-conditioning products Residential & VRF News 2015

State of the Art Energy Efficient Data Centre Air Conditioning

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 ton Dual Circuits R-410A R-410A 1 R-410A

The Different Types of Air Conditioning Equipment for IT Environments

ARMSTRONG AIR HEAT PUMPS

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Defining Quality. Building Comfort. Heating and Cooling Coils

Element D Services Heating, Ventilating, and Air Conditioning

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

CRAC Precision climate control units for data centres

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Innovent LASER Packaged Fresh Air Conditioning Units

5-60kW. EasiCool Range. - 60kW. Typical Applications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Failure code manual. content

MINI-MATE 2 HEAT REMOVAL ENGINEERING MANUAL

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

STULZ Solutions and Services

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

marine/bespoke split applications

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

PMI-IF-H High Efficiency Gas Heat Units

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Chilled Water Precision Air Conditioner For Critical Application

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Why Do I Need Precision Air Conditioning?

ECOCIAT. Domestic hot water heat recovery unit

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

Air-Cooled Condensers

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

EasiCool. 6-64kW DX AIR. Precision Air Conditioning

Cool Design for Homes and Offices

HVAC INDOOR MAKE-UP AIR HANDLERS

Lesson 36 Selection Of Air Conditioning Systems

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Glossary of Heating, Ventilation and Air Conditioning Terms

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

SMM. Installation Operation Maintenance

RPV - RP - RA air handling units

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Chilled Water HVAC Systems

DATA CENTER HVAC (LIEBERT) PROCUREMENT AND RELOCATION, REDESIGN AND INSTALLATION OF EXISTING COOLING SYSTEM

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

Tech Byte 27: Small Computer Room and IT Closet Cooling

Cooling kw Heating kw

HVAC Systems: Overview

1.2 Refrigerant Equipment. General

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Commercial Gas Furnace Upflow

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

HEAVY DUTY STORAGE GAS

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Split System Cooling Product Data

HVAC Processes. Lecture 7

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

LOBOY 16 AIR CONDITIONERS

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

STULZ Water-Side Economizer Solutions

AIR-COOLED CONDENSERS Technical Guide

SustainE(Sustainable Energy)

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

Transcription:

LIEBERT CORPORATION Air Products Model Number erence Guide Revision: April 2004

MODEL NUMBER INDEX BEGINNING MODEL PRODUCT PAGE FD, UD Deluxe System 2 1 FH, FE, UH, UE Deluxe System 3 1 DH, DE, VH, VE, FH, UH Deluxe System 3 2 DS, DD, CS,, CT Chiller CSU3000 3 PS Process Chiller 3 UP Industrial Cooling System 4 CU, CF, CE, CK Challenger 2 or Challenger 3 4-5 BF, BE, BU, BK Challenger 3000 6 HMU, HMF HiMod 6 SD, SE, SU, SK Modular Plus 7 DCSF, DF, CSF, F Air Condenser 8 DDNT, DNT, DNF Drycooler 8 D0NT150, D0NS150, DGNT120, DGNS120 10 Fan Drycooler 9 MM MiniMate 9-10 MMD, MM0 MiniMate 2 11 M, MC0 MiniMate 2 Condenser 12 DM DataMate 13-14 PFC, PFH Prop Fan Condenser 14 ET Intelecool 15 XD Extreme Density 16-17

Parts Manuals do not include Special Feature Applications (SFA). They do include standard features and options for the respective products. If the equipment has a SFA, it is usually signified in the complete model number. It is usually best to contact the factory for replacement parts on equipment with SFA s due to the wide variety. Below is an example of a standard configured model and a SFA configured model for a Deluxe System 3. Standard Model DH199A-AAEI 5754 Special Feature Model DH199A-AAEI S165 Model number and options Model number and options Standard Configure Number (Determined by serial number) SFA Configure number (Determined by serial Number)

1. LARGE FLOOR SYSTEMS DELUXE SYSTEM 2 Models FD/UD Production 1973 to January 1983 FD 116 G FD = Down-flow UD = Up-flow A = Air W= Deluxe System 2 Parts Manual See chart below G = Glycol C = Chilled Many of the electronic controls are no longer available. Require upgrade kits for electronics. Check with factory. Deluxe System 2 Tonnage Chart Tonnage 6 8 10 15 20 22 Air 075A 114A 125A 199A 245A 290A 086W 127W 138W 219W 267W 315W Glycol 072G 110G 116G 192G 240G 265G Chilled 139C, 173C 190C, 237C, 280C 305C 386C 411C 422C 529C DELUXE SYSTEM 3 Models FH/UH & FE/UE Production 1983 to January 1999 FH 199 A U A 01 FH = Down-flow UH= Up-flow FE = Down- flow w/econ-o-coil UE = Up-flow w/econ-o-coil See chart below A = Air W= G = Glycol C = Chilled - = 2 Step DX or Std CW U = 4 Step DX V = Variable Speed Drive (VSD) CW A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 01 = Level 01 02 = Level 02 03 = Level 03 00 = Level 00 10 = Level 10 15 = Level 15 Deluxe System 3 Level 1,2,3 Deluxe System 3 Level 1,2,3 Deluxe System 3 Level 1,2,3 Deluxe System 3 Level 0,10 Deluxe System 3 Level 0,1 Not Available Many controls for the 01, 02, 03, 10 & 15 are no longer available. Require upgrade kits for electronics. Check with factory. Page 1

DELUXE SYSTEM 3 Models DH/VH & DE/VE (CW SYSTEMS FH&UH) Production February 1999 to Present DH 138 W U A A E S DH = Downflow DX VH= Up-flow DX DE = Downflow w/econo-coil VE = Up-flow w/econ-o-coil FH = Downflow CW UH = Up-flow CW See chart below A = Air W= G = Glycol C = Chilled - = 2 Step DX or Std CW U = 4 Step DX V = Variable Speed Drive (VSD) CW H = DX w/hot Gas Bypass A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 F = 380/3/50 G = 415/3/50 H = 230/3/50 J = 200/3/50 U = 400/3/50 S = Standard A = Advanced G = Advanced Graphics 0 = No E = Electric H = Hot G = Hot Gas T = Steam 0 = No I = Infrared G = Steam Grid S = Steam Generating See notes below DH & DE Manuals are located on the web at www.liebert.com/products/parts_manual.asp others - contact the factory. Deluxe Systems Tonnage Chart Tonnage 6 8 10 15 20 22 30 40 50 Air 075 114 125 199 245 290 380 086 127 138 219 267 315 412 Glycol 072 110 116 192 240 265 363 Chilled 147 200 248 302 376 422 529 600 740 Page 2

CHILLER CSU Models CS//CT & DS/DD Production 1979 to Present 182 A - A DS = Single Module, 2 ½ or 5 Ton DD = Dual Module, 2 ½ or 5 ton A = Air W= G = Glycol A = 460/3/60 B = 575/3/60 C = 208/3/60 Chiller CSU3000 CS = Single Module, 7 ½, 10, 12 or 15 Ton = Dual Module, 7 ½, 10, 12 or 15 Ton CT = Triple Module, 20, 30 or 37-1/2 Ton L = Glycool D = 230/3/60 PROCESS FLUID CHILLER Models PS Production 1996 - Present PS 036 A P B 3 0 PS = Process Chiller Capacity in 1 Ton = 018 2 Ton = 024 3 Ton = 036 A = Air A = 460/3/60 Y = 208/230-1-60 S = Stainless Steel Pump B = Gauge/Heater/SS Pump M = Multi-Stage Pump (8/10 Ton Only) 3 = Revision Level 4 = Revision Level for 8/10 Models 0 = No Tank T = 100 Gallon Tank Web Process Fluid Chiller 4 Ton = 048 5 Ton = 060 8 Ton = 096 R = Gauge/Heater/Mult i-stage Pump (8/10 Ton Only) 10 Ton = 120 Page 3

INDUSTRIAL COOLING SYSTEM (ICS) Models UP Production 1990 to Present UP 126 A U A 10 UP = Up-flow A = Air W= G = Glycol - = 2 Step DX or Std CW U = 4 Step DX A = 460/3/60 B = 575/3/60 C = 208/3/60 00 = Level 00 10 = Level 10 See Notes Below C = Chilled D = 230/3/60 15 = Level 15 SM = Standard AM = Advanced AG = Advanced Graphics No published parts manual for ICS Systems, contact factory. Level 10 controls not available. Require upgrade kits for electronics. Check with factory. CHALLENGER 2 Models CF & CU Production 1978 to 1986 CU 066 A CF = Down-flow CU = Up-flow Capacity in A = Air W= Challenger 2 Parts Manual See chart below G = Glycol C = Chilled Most controls are no longer available. Require upgrade kits for electronics. Check with factory. Page 4

CHALLENGER 2 LEVEL 00 Models CF & CU Production 1986 to 1994 CU 047 A - A 00 CF = Down-flow CU = Up-flow See chart below A = Air W= G = Glycol - = Std DX or Std CW A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 00 = Level 00 Challenger 2 Level 00 Parts Manual C = Chilled Challenger 2 Systems Tonnage Chart Tonnage 3 Ton 5 Ton Air 043 066 047 069 Glycol 041 060 Chilled 091 CHALLENGER 3 LEVEL 00 Models CF/CU & CE/CK Production 1986 to 1994 CU 046 WG - A 00 CF = Down-flow CU = Up-flow CE = Down-flow w/econ-o-coil CK = Up-flow w/econ-o-coil See chart below A = Air W= G = Glycol C = Chilled - = Std DX or Std CW A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 00 = Level 00 Challenger 3 Parts Manual Challenger 3 Systems Tonnage Chart Tonnage 3 Ton 5 Ton Air 042 067 046 071 Glycol 061 Chilled 068 102 Page 5

CHALLENGER 3000 Models CF & CU Production 1986 to 1994 BF 042 A - A A E I BF = Down-flow BE = Down-flow w/econ-o-coil BU = Up-flow BK = Up-flow w/econ-o-coil See chart below A = Air W/G= /Glycol C = Chilled E = Evaporator - = Std DX or Std CW A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 S = Standard A = Advanced G = Advanced 0 = No reheat E = Electric H = Hot G = Hot Gas S = SCR 0 = No I = Infrared S = Steam Generating Challenger 3000 Parts Manual Challenger 3000 Systems Tonnage Chart Tonnage 3 Ton 5 Ton Air 042A 067A 046WG 071WG Glycol 061G Chilled 068C 102C Fan Coil 036E 060E HIMOD Models HM Production 2001 - Present HM F 028 A I A A E S HM U = Up-flow F = Downflow Capacity (KW) 28 34 40 A= Air G Glycol K = Glycool D = Dual Cool w/air I = 407C 0 = R22 A = 460/3/60 C = 208/3/60 D = 230/3/60 S = Standard A = Advanced G = Advanced 0 = No reheat E = Electric 0 = No S = Steam Generating Himod Parts Manual - Preliminary H = Dual Cool w/glycol Page 6

MODULAR PLUS Models SD/SU & SE/SK Production 1988 to 1991 SD 096 A - A 00 SD = Down-flow SE = Down-flow w/ Econ-o-coil SU = Up-flow SK = Up-flow w/econ-o-coil A = Air W = G = Glycol - = Std DX or Std CW U = 4 Step DX 6 = 6 Step DX A = 460/3/60 B = 575/3/60 C = 208/3/60 D = 230/3/60 00 = Level 00 10 = Level 10 Modular Plus Modular Plus Systems Tonnage Chart Tonnage 7.5 Ton 10 Ton 12 Ton Air 096A 124A 149A 107W 140W 165W Glycol 093G 120G 143G 6 step configurations have been modified. Contact factory regarding replacement compressors. Page 7

2. HEAT REJECTION AIR COOLED CONDENSERS & DRYCOOLERS Models CSF/F & DS*/ DD* Production 1973 Present Variations of models through the years CONDENSERS D C D F 104 A D = Optional Disconnect Switch C = Air Condenser S = Single rigerant Circuit F = Fan Speed Control Model Size Y = 208/230-3-60 See Notes Below D = Dual rigerant Circuit L = Main Control / Lee Temp C = No Control / Chiller Lee Temp T = Ambient Fan Cycle S = Special A = 460-3-60 B = 575-3-60 Z = 460-1-60 V = 575-1-60 erence books for product built prior to 1990 s see Condenser Parts Manual. For product built 1990 s and later, see Condenser-Drycooler, Lee Temp. DRYCOOLERS D D N T 1 3 9 A D D N T 139 A D = Optional Disconnect Switch D = Drycooler N = No Pump S = Single Pump C = No Control L = Main Control Model Size Y = 208/230-3-60 A = 460-3-60 Optional circuiting (per catalog) See Notes Below D = Dual Pump T = Ambient Fan Cycle O = Fan Cycle & Pump Control S = Special F = Fan Speed Control G = Glycool Chiller B = 575-3-60 Z = 460-1-60 V = 575-1-60 erence books for product built prior to 1990 s see Condenser Parts Manual. For product built 1990 s and later, see Condenser-Drycooler, Lee Temp. Page 8

10 Fan Drycooler Models DTNT Production 1999-2002 D 0 N T 1 5 0 A N 1 3 6 A 0 0 D 0 N T 150 A N 136 A 0 0 D = Drycooler 0 = Std 10 Fan G = Quiet Line 10 Fan T = TEAO 10 Fan N = 0 Pumps T = Fan Cycling X = Fan Cycling w/current Sensing S = No Control W = No Control w/ Current Sensing Relays Capacity: 150 = 150 Tons (60 & 50 Hz) 120 = 120 Tons (60 Hz) Quiet Line A= 460-3-60 B = 575-3-60 C = 208-3-60 D = 230-3-60 M = 380/415-3-50 Guards: N = None G = Wire A = Aluminum This model was produced by Dunham-Bush. Parts Manuals are located on the web. # of Coil Circuits: 068 = Half 136 = Full 272 = Double Coil Type: A = Aluminum C = Phenolic Coated Coil P = Precoated Fin U = Cu/Cu 0 = Std S = SFA 0 = Std S = SFA 3. SMALL SYSTEMS MINIMATE Models MM18A, MM20W, MM23C Production 1980 S MM 18 A - B 208 MM = MiniMate 18A 20W A = Air W = C = Chilled - B =Basic R = (Electric) 208 = 208 Volt 230 = 230 Volt 277 = 277 Volt MiniMate Parts Manual Rev 8-90 Page 9

MINIMATE & MINIMATE PLUS SOLID STATE CONTROLS Models MME, DMC MME 018 E - P H 0 MME = Mini- Mate Ceiling Unit DMC = Outdoor Condensing Unit E = Evaporator Only A = Air W/G = /Glycol Condenser C = Chilled /Glycol Condensers WG = 2-Way 150 PSI WH = 2-Way 300 PSI W3 = 3-Way 150 PSI WT = 3-Way 300 PSI - = Standard X = 277-1-60 H = With and 0 = Cooling Only L = Lee- Temp (Condensing Unit Only) 0 = Revision Level No book available MINIMATE PLUS MICROPROCESSOR CONTROLS Models MME, MMC, DMC MME 018 E - A 0 1 MME = Mini- Mate Ceiling Unit MMC = Mini- Mate Plus Condensing Section DMC = Outdoor Condensing Unit Capacity in E = Evaporator Only A = Air WG = /Glycol Condenser C = Chilled W = G = Glycol AC = DMC with Coated Coil A = 460-3-60 B = 575-3-60 X = 277-1-60 Y = 208/230-3-60 H = With O = No C = Cooling Only L = Lee-Temp (Condensing Unit Only) or Glycol O = 2-Way 150 PSI H = 2-Way 300PSI 3 = 3-Way 150 PSI T = 3-Way 300 PSI 1 = Revision Level MiniMate Plus Parts Manual Rev 3-91 Page 10

MINIMATE2 Models 1,1-1/2, 2, 3 & 2 5-8Ton Models Produced 1997 - Present MM D 12 A - P H E D 0 MM D = Disconnect O = No Disconnect Capacity in Thousan d (See Chart Below) A = Air W = C= Chilled E = Split Evaporat or F = Air w/ Free Cooling G = /Gl ycol w/ Free Cooling K = Evaporat or w/free Cooling - = DX 2 = 2-Way Chilled Valve 3 = 3-Way Chilled Valve X = 277-1-60 S = 220/240-1-50 A = 460-3-60 Y = 208230-3-60 M = 380/400-3-50 H = Canister 0 = No R = Remote Contact J = Canister & Remote Contact Manuals are located on the web at www.liebert.com/products/parts_manual.asp. 0 = No E = Electric S = SCR H = Hot 0 = No Hot Gas Bypass (1 & 1-1/2 Ton Models Only) H = Hot Gas Bypass (1 & 1-1/2 Ton Models Only) D = Direct Drive Blower (2 & 3 Ton Models Only) B = Belt Drive Blower (2 & 3 Ton Models Only) L = Low Speed Drive (5 & 8 Ton Only) H = High Speed Drive (5 & 8 Ton Only) Options: 0 = None A = Filter Clog B = Smoke Detector C = Firestat D = Filter Clog & Smoke Detector E = Filter Clog & Firestat F = Smoke Detector & Firestat G = Filter Clog, Smoke Detector, & Firestat Page 11

MINIMATE2 Models 2-3 & 5-8 Ton Condenser Models Produced 1997 - Present M C D 24 A - P H 3 M =MiniMate2 C = Condensing Unit D = Disconnect 0 = No Disconnect (See Chart Below) A = Air W = - Standard L = 95F Ambient Lee Temp 2 = 2-Way Std Press Valve X = 277-1-60 S = 220/240-1-50 A = 460-3-60 H = Hot Gas Bypass Revision Level 3 = 3-Way Std Press Valve D = 2-Way High Pressure Valve Y = 208230-3-60 M = 380/400-3-50 T = 3-way High Pressure Valve Manuals are located on the web at www.liebert.com/products/parts_manual.asp and are part of the MiniMate2 2-3 Ton Systems Manual. MiniMate2 System Tonnage Chart Tonnage 1 1-1/2 2 3 5 8 Self Contained Air 12A 18A 24A 36A Split System 12E 18E 24E 36E 60E 96E Evaporator Self Contained 14W 20W 26W 38W /Glycol Chilled 23C 40C 92C 8TC Page 12

DATAMATE Models DME, DMC Produced 1986-2000 Variations of models through the years DME 020 E - P H 0 DME = DataMate Evaporator Section DMC = DataMate Condensing Section E - = Evaporator Only A - = Air W/G = /Glycol Condenser C - = Chilled W - = G - = Glycol X = 277-1-60 A = 460-3-60 Y = 208230-3-60 H = With O = No C = Cooling Only L = Lee-Temp (Condensing Unit Only) or Glycol O = 2-Way 150 PSI H = 2-Way 300PSI 3 = 3-Way 150 PSI T = 3-Way 300 PSI 0 = Revision Level DataMate Parts Manual Rev 1992 (Covers Product built in Europe as well as generation 2 product). Note: Many of the DataMate European parts are not available. This product was built prior to 1988. Consult Factory. Page 13

DATAMATE Models DME, DMC Produced 2000-Present Variations of models through the years DME 020 E - P H 3 DME = DataMate Evaporator Section DMC = DataMate Condensing Section E - = Evaporator Only A - = Air W/G = /Glycol Condenser C - = Chilled W - = G - = Glycol X = 277-1-60 A = 460-3-60 Y = 208230-3-60 H = With O = No C = Cooling Only L = Lee-Temp (Condensing Unit Only) or Glycol O = 2-Way 150 PSI H = 2-Way 300PSI 3 = 3-Way 150 PSI T = 3-Way 300 PSI 3 = Revision Level DataMate European Parts Manual (for product built prior to 1988) DataMate Parts Manual Rev 1992 (Also includes European Product) Note: Parts Manual for the current DataMate are not available. Please contact the factory. PROP FAN CONDENSER Models PFC Produced 1997 Present PFC 0 37 A - P L 0 PFC = Prop Fan Condensing Unit PFH = Prop Fan Condensing Unit w/hot Gas Bypass 0 = Standard Sound Level Z = Quiet Line Capacity in Thousan d A = Air - = Standard Coil C = Coated Coil Y = 208230-3-60 2 = 380-3-60 A = 460-3-60 B = 575-3-60 L =95F Ambient Lee Temp H = 105F Ambient Lee Temp 0 = Revision Number Web Prop Fan Condenser Page 14

4. TELECOMMUNICATION SYSTEMS INTELECOOL 1 Models ET ET 036 A - P 0 0 ET = External Telecomm 2 Ton =24 3 Ton = 36 A = Air - = Standard S = 220/240-1-50 A = 460-3-60 Y = 208/230-3-60 N = 200/230-3-50 M = 380/420-3-50 0 = Standard F = Fixed Outside Air Damper E = Economizer 0 = No Heat A = 5KW Heat B = 10KW Heat C = 15KW Heat Intelecool 1 INTELECOOL 2 Models ET Produced 1998 - Present ET 036 H R P F B T ET = External Telecomm Capacity in Thousan d H = Hermetic Compressor S = Scroll Compressor R = Right Compressor L = Left Compressor M = 380/420-3-50 0 = Standard F = Fixed Air Damper E = Economizer 0 = No Heat A = 5KW Heat B = 10KW Heat C = 15KW Heat T = Tan Painted Steel Panels C = Custom Color A = Aluminum Intelecool 2 Page 15

5. EXTREME DENSITY SYSTEMS EXTREME DENSITY Models XDA Produced 2003 - Present XD A 5 B K XD = Liebert Extreme Density System A = Air Flow Enhancer 5 = 5 Fans B = Basic Unit K = 120-1-60 T = 230-1-60 See Notes Below Parts Manual for the XD Products are not available. Please contact the factory. EXTREME DENSITY Models XDO Produced 2003 - Present XD O 32 B C XD = Liebert Extreme Density System O = Overhead Cooling Module 32 = Capacity B = Basic Unit D = Condensate Detection C = 208-3-60 D = 230-3-60 See Notes Below Parts Manual for the XD Products are not available. Please contact the factory. EXTREME DENSITY Models XDV Produced 2003 - Present XD V 8 B T XD = Liebert Extreme Density System V = Vertical Top Cooler 8 = 8KW Capacity B = Basic Unit D = Condensate Detection K = 120-1-60 T = 230-1-60 See Notes Below Parts Manual for the XD Products are not available. Please contact the factory. Page 16

EXTREME DENSITY Models XDP Produced 2003 - Present XD P 160 B A XD = Liebert Extreme Density System P = Pumping Unit 160 = 160 KW B = Basic Unit R = Pump Redundancy C = 208-3-60 A = 460-3-60 See Notes Below Parts Manual for the XD Products are not available. Please contact the factory. EXTREME DENSITY Models XDR Produced 2003 - Present RC 08 C - K 0 RC = RackCooler 08 = 8KW Capacity C = Chilled - = Standard K = 120-1-60 S = 230-160 0 = Revision Level See Notes Below Parts Manual for the XD Products are not available. Please contact the factory. Page 17