LG Multi Type Air Conditioner



Similar documents
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

ROOM AIR CONDITIONER INSTALLATION MANUAL

Split Type Room Air Conditioner. KSWM units

Portable Air Conditioner

LG Floor Standing Type Air Conditioner INSTALLATION MANUAL

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

AIR CONDITIONER INSTALLATION MANUAL

Room Air Conditioner SERVICE MANUAL. website CAUTION

Room Air Conditioner SVC MANUAL(General)

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

Operating Instructions Split System Air Conditioner

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

AIR-CONDITIONER SPLIT TYPE

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

LG Multi Type Air Conditioner

Operating Instructions Air Conditioner

AIR CONDITIONER INSTALLATION MANUAL

WINDOW ROOM AIR CONDITIONER

Wall Mounted Mini Split Heat Pump Air Conditioner

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

OPTIONAL SLENDER REMOTE CONTROL

Room Air Conditioners

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

USER S MANUAL HSC-24A

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

SPLIT -TYPE ROOM AIR CONDITIONER

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Operating Instructions Air Conditioner

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

14. Troubleshooting Guide

Dehumidifier Users manual. For Models: DH45S DH65S

SWIMMING POOL HEAT PUMP

9ASNA-A SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Inverter Single Zone Ductless Mini Split Heat Pump

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

CEILING CASSETTE TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Split Air Conditioner

Instruction manual for Firstline FCS12000CH

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

INDOOR UNIT/OUTDOOR UNIT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Wall Mounted Mini-Split System Air Conditioning/Heat Pump Service Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

LG Room Air Conditioner OWNER'S MANUAL

LG Room Air Conditioner OWNER'S MANUAL

PORTABLE AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

CS-CE9NKE CS-CE12NKE CU-CE9NKE CU-CE12NKE TABLE OF CONTENTS WARNING

Room Air Conditioner SVC MANUAL(General)

Split Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Room Air Conditioner SERVICE MANUAL MODELS: LAN181CNW(ASNC183VML3) LAU181CNW(ASUC183VML3) website CAUTION

Use and Care Manual. Model CPA12KH AIR CONDITIONER

AIR CONDITIONER (SPLIT TYPE)

Reverse Cycle Inverter Split System Air Conditioner

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

INSTALLATION INSTRUCTIONS

R410A SPLIT SERIES DC INVERTER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER (J Series)

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

PORTABLE AIR CONDITIONER

TECHNICAL SERVICE MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

CEILING DUCT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

TABLE OF CONTENTS. Air Conditioner. Indoor Unit Outdoor Unit CS-NE9MKE CU-NE9MKE CS-NE12MKE CU-NE12MKE CS-XE9MKE-5 CU-NE9MKE CS-XE12MKE-5 CU-NE12MKE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Wall Mounted Mini-Split System Air Conditioning/Heat Pump

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E

Room Air Conditioner SVC MANUAL(Exploded View)

Hi Wall Split Air Conditioners

DUCT TYPE AIR CONDITIONER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

CS-HE9NKE CS-HE12NKE CS-AE9NKE CU-HE9NKE CU-HE12NKE CU-AE9NKE TABLE OF CONTENTS WARNING

Important Safeguards

DUCTED SPLIT TYPE AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Service manual. Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

Ductless Split Air Conditioner

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS SINGLE SPLIT WALL MOUNTED AIR CONDITIONER

Transcription:

website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Multi Type Air Conditioner SERVICE MANUAL LG MODEL: L3-C363LA0 L3-C363MA0 L3-C363NA0 L3-H363LA0 L3-H363MA0 L3-H363NA0 CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. ONLY FOR AUTHORIZED SERVICE PERSONNEL.

Multi Air Conditioner Service Manual TABLE OF CONTENTS Safety Precautions...3 About MPS...7 Product Specifications...8 Dimensions...10 Refrigeration Cycle Diagram...12 Wiring Diagram...13 Electronic Control Device...14 Schematic Diagram...17 Functions...20 Operation Details...23 2-way, 3-way Valve...30 Cycle Troubleshooting Guide...34 Electronic Parts Troubleshooting Guide...42 Operation...56 Disassembly of the parts (Indoor unit)...58 Exploded View and Replacement Parts List...60 2 MPS Multi Air Conditioner

Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. Meanings of symbol used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. There is risk of fire or electric shock. WARNING Do not let the air conditioner runforalongtimewhenthe humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture. Always ground the product. There is risk of fire or electric shock. Install the panel and the cover of control box securely. Thereisriskoffireorelectricshock. Always install a dedicated circuit and breaker. Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse. There is risk of fire or electric shock. Service Manual 3

Safety Precautions Do not modify or extend the power cable. There is risk of fire or electric shock. Do not install, remove, or reinstall the unit by yourself (customer). There is risk of fire, electric shock, explosion, or injury. Be cautious when unpacking and installing the product. Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator. For installation, always contact the dealer or an Authorized Service Center. There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. Operational Do not touch(operate) the product with wet hands. Donotplaceaheaterorother appliances near the power cable. Do not allow water to run into electric parts. There is risk of fire or electrical shock. There is risk of fire and electric shock. It may cause There is risk of fire, failure of the product, or electric shock. 4 MPS Multi Air Conditioner

Safety Precautions Do not store or use flammable gas or combustibles near the product. There is risk of fire or failure of product. If strange sounds, or smell or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire. Gasolin Do not open the inlet grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure. Be cautious that water could not enter the product. There is risk of fire, electric shock, or product damage. Service Manual 5

Safety Precautions Installation check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product. CAUTION Install the drain hose to ensure that water is drained away properly. A bad connection may cause water leakage. Keep level even when installing the product. To avoid vibration or water leakage. 90 Operational Use two or more people to lift and transport the product. Avoid personal injury. Useasoftclothtoclean.Do not use harsh detergents, solvents, etc. There is risk of fire, electric shock, or damage to the plastic parts of the product. Do not touch the metal parts of the product when removing the air filter. They are very sharp! There is risk of personal injury. Wax Thinner Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and failure of product. Do not insert hands or other objects through the air inlet or outlet while the product is operated. There are sharp and moving parts that could cause personal injury. 6 MPS Multi Air Conditioner

About MPS About MPS MPS (Multi Power System) Conventional (On/Off Operation) Indoor Temp ( C) 27 25 23 21 19 0 ON OFF ON OFF 0:05 0:10 0:15 0:20 Operation time (min) During a Conventional Air Conditioning Cycle, the Compressor must turn on and off to reach desired Temperature setting. A large portion of power is used during Restart. This causes unnecessary power consumption. MPS Indoor Temp ( C) 27 25 23 21 19 0 100% operation 40% operation 0:05 0:10 0:15 0:20 Operation time (min) MPS(Multi Power System) is a power saving system With Two rotary compressors of different capacity (60% & 40%) Operating an A/C at high power until it reaches desired temperature. And when it reaches the temperature, only the 40% Capacity rotary compressor operates. Service Manual 7

Product Specifications Product Specifications 1. L3-C363LA0, L3-C363MA0, L3-C363NA0 Item Operation Unit 3-Unit On 2-Unit On 1-Unit On Remarks Cooling Capacity Heating Capacity Btu/h(kcal/h) Moisture Removal /h Power Source ø, V,Hz Air Circulation /min Noise Level db(a) ( Hi / Med / Low ) Input Cooling W Heating Runnig Cooling Current Heating A E.E.R. Cooling Btu/h. w C.O.P. Heating - Dimensions(WxHxD) mm Net. Weight kg Service Valve mm(inch) Refrigerant(R-22) g Airflow Direction Control(Up & Down) Remote Controller Type Sleeping Operation Drain Hose 34,200/36,000 22,800/24,000 11,400/12,000 208/230V - - - - 3.6 2.4 1.2 at 230V 1Ø, 208/230V, 60Hz Indoor 8 Outdoor 63 Indoor 40/38/36 Outdoor 54 at 230V 4,020/4,020 2,530/2,530 1,340/1,340 17.9/17.9 11.6/11.6 5.9/5.9 208/230V 8.5/8.9 9.0/9.5 8.5/8.9 Indoor 888x287x170 Outdoor 870 x 1060 x 320 Indoor 9 Outdoor 78 Liquid 6.35(1/4) Gas 12.7(1/2) 2,500 at 7.5m O L.C.D Wireless O O 8 MPS Multi Air Conditioner

Product Specifications 2. L3-H363LA0, L3-H363MA0, L3-H363NA0 Item Operation Unit 3-Unit On 2-Unit On 1-Unit On Remarks Cooling Capacity Heating Capacity Btu/h(kcal/h) Moisture Removal /h Power Source ø, V, Hz Air Circulation /min Noise Level db(a) ( Hi / Med / Low ) Input Cooling W Heating Runnig Cooling Current Heating A E.E.R. Cooling Btu/h. w C.O.P. Heating - Dimensions(W x H x D) mm Net. Weight kg Service Valve mm(inch) Refrigerant(R-22) g Airflow Direction Control(Up & Down) Remote Controller Type Sleeping Operation Drain Hose 34,600/36,000 23,040/24,000 11,500/12,000 208/230V 3.6 2.4 1.2 at 230V 1Ø, 208/230V, 60Hz Indoor 8 Outdoor 63 Indoor 40/38/36 Outdoor 54 at 230V 3,920/3,920 2,660/2,660 1,500/1,500 17.5/17.5 12.2/12.2 6.7/6.7 208/230V 8.8/9.2 8.7/9.0 7.7/8 Indoor 888 x 287 x 170 Outdoor 870 x 1060 x 320 Indoor 9 Outdoor 78 Liquid 6.35(1/4) Gas 12.7(1/2) 2,500 780 780 at 7.5m O L.C.D Wireless O O Service Manual 9

Dimensions Dimensions 1. Indoor Unit D H W Tubing hole cover Installation plate Left rear piping Right rear piping Center A A Center A A ø70mm ø70mm DIM MODEL L3-C363LA0, L3-C363MA0, L3-C363NA0 L3-H363LA0, L3-H363MA0, L3-H363NA0 W mm 888 H mm 287 D mm 170 10 MPS Multi Air Conditioner

Dimensions 2. Outdoor Unit W H L4 L3 L10 L11 L11 L11 L11 L11 L2 D L1 Gas side 3-way valve Liquid side 2-way valve L5 L7 L6 L8 L9 MODEL L3-C363LA0, L3-C363MA0, L3-C363NA0 DIM L3-H363LA0, L3-H363MA0, L3-H363NA0 W mm 870 H mm 1038 D mm 320 L1 mm 360 L2 mm 340 L3 mm 25 L4 mm 1035 L5 mm 25 L6 mm 546 L7 mm 160 L8 mm 160 L9 mm 44 L10 mm 64.5 L11 mm 50 Service Manual 11

Refrigeration Cycle Diagram Refrigeration Cycle Diagram 1. L3UH363LA0, L3UH363MA0, L3UH363NA0 Indoor Side Outdoor Side 4- WAY Valve C B A Accum. COMP A COMP B 2. L3UC363LA0, L3UC363MA0, L3UC363NA0 Indoor Side Outdoor Side C B A Accum. COMP A COMP B ex) Capillary Solenoid Valve L.E.V 3-Way Valve 2-Way Valve 12 MPS Multi Air Conditioner

Wiring Diagram Wiring Diagram Indoor Unit L3-C363LA0, L3-C363MA0, L3-C363NA0 L3-H363LA0, L3-H363MA0, L3-H363NA0 MAIN PCB ASSY MOTOR CN-MOTOR SW01F FORCED OPERATION AUTO RESTART REMOTE CONTROL CN-POWER CN-U/D CN-TH1 CN-TH2 THERMISTOR (OUT PIPE) THERMISTOR (IN PIPE/AIR) STEP MOTOR CN-DISP1 RD BK BR BL C G V S PILLAR TERMINAL DISPLAY PCB ASSY TO OUTDOOR UNIT INDOOR WIRING DIAGRAM 3854A24002C Outdoor Unit L3-C363LA0, L3-C363MA0, L3-C363NA0 L3-H363LA0, L3-H363MA0, L3-H363NA0 Service Manual 13

Electronic Control Device Electronic Control Device Indoor Unit MAIN P.C.B DC ASM 14 MPS Multi Air Conditioner

Electronic Control Device Outdoor Unit MAIN P.C.B DC ASM Service Manual 15

Electronic Control Device Display P.C.B ASM 16 MPS Multi Air Conditioner

Schematic Diagram Schematic Diagram Indoor Unit Service Manual 17

Schematic Diagram Outdoor Unit 18 MPS Multi Air Conditioner

Service Manual 19 Schematic Diagram

Functions Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature sensor. (THERMISTOR) Room temperature control Maintains the room temperature in accordance with the Setting Temp. Starting Current Control Indoor fan is delayed for 5 seconds at the starting. Time Delay Safety Control Restarting is inhibited for approx. 3 minutes. Indoor Fan Speed Control High, Med, Low, Chaos Operation indication Lamps (LED) OUT DOOR --- Lights up in operation --- Lights up in Sleep Mode --- Lights up in Timer Mode --- Lights up in Deice Mode(for Heat pump model) --- Lights up in Compressor operation(for Cooling model) Health Dehumidification Operation Intermittent operation of fan at low speed. Sleep Mode Auto Control The fan is switched to low(cooling), med(heating) speed. The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours. Natural Air Control by CHAOS Logic The fan is switched to intermittent or irregular operation The fan speed is automatically switched from high to low speed. Airflow Direction Control The louver can be set at the desired position or swing up and down automatically. Deice (defrost) control (Heating) Both the indoor and outdoor fan stops during deicing. Hot start after deice ends. Hot-start Control (Heating) The indoor fan stops until the evaporator piping temperature will be reached at 28 C. 20 MPS Multi Air Conditioner

Functions Remote Controller Operation ON/OFF Operation Mode Selection (Cooling model only) (Heating model only) Cooling Operation Mode.( ) Healthy Dehumidification Operation Mode.( ) Auto Operation Mode.( ) Heating Operation Mode.( ) Fan Speed Selection (Low) (Med) (High) (CHAOS) Room, Temperature Display : High: 39 C(102 F) LOW : 11 C(52 F) Temperature Setting TEMPERATURE HIGH LOW Cooling Down to 18 C(64 F) Up to 30 C(86 F) Heating Down to 16 C(60 F) Up to 30 C(86 F) JET COOL Setting the Time or Timer Timer Selection ON OFF : OFF, ON, OFF ON Timer Setting SET Timer Cancel CANCEL : Cancel Sleep Mode, Timer ON or Timer OFF Sleep Operation : 1, 2, 3, 4, 5, 6, 7, Off Timer Airflow Direction Control C To F Swtiching Button C / F Fan Operation Mode Reset : Fan Operates without cooling or heating. Service Manual 21

Display Function Display Function 1. Heating Model 2. Cooling Model Operation Indicator Cooling, Soft Dry, Fan, Heating Sleep Timer Indicator Sleep Mode Timer Indicator Timer Mode Defrost Indicator Hot-start, Defrost Operation Indicator Cooling, Soft Dry, Fan Sleep Timer Indicator Sleep Mode Timer Indicator Timer Mode Compressor on Indicator OUT DOOR Self-diagnosis Function Error Indicator The function is to self-diagnosis air conditioner and express the troubles if there is any trouble. Error mark is displayed on display window of indoor units and wired-remote controller, and LED of outdoor unit control board. If more than two troubles occur simultaneously, lower number of error code is first displayed. After error occurs, if error is released, error LED is also released simultaneously. 1 digit (Operation LED) 10 digit (Sleep LED) Indoor Error Error code 01 02 05 06 Contents Air sensor (open/short) Inlet pipe sensor Communication(Indoor Outdoor) Outlet pipe sensor Case of error Open / Short Open / Short Communication Poorly Open / Short Operation Led 1 time 2 time 5 time 6 time Indoor Status Sleep Indoor Led Fan off off off off On or stop On or stop Off On or stop Vane Open Open Close Open Outdoor Status Comp & LEV Fan Open On or stop or Close On or stop Open or Close Off On or stop Close Open or Close 07 Different mode operation Different mode operation 7 time off Off Close Off Close Outdoor Error 44 45 51 Outdoor Air sensor Cond. Pipe sensor Capacity over Error Open / Short Open / Short Total Indoor capacity over 4 time 5 time 1 time 4 time 4 time 5 time Off Off Off Close Close Close Off Off Off Close Close Close 22 MPS Multi Air Conditioner

Operation Details Operation Details Main Unit Function 1) C/O Model Operation Indicator On while in appliance operation, off while in appliance pause Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on) Sleep Timer Indicator On while in sleep timer mode, off when sleep timer cancel or appliance operation pause Timer Indicator On while in timer mode (on/off), off when timer mode is completed or canceled. Comp. Running Incidator While in appliance operation, on while in outdoor unit compressor running, off while in compressor off 2) H/P Model Operation Indicator On while in appliance operation, off while in appliance pause Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on) Sleep Timer Indicator On while in sleep timer mode, off when sleep timer cancel or appliance operation pause Timer Indicator On while in timer mode (on/off), off when timer mode is completed or canceled Defrost Indicator Off except when hot start during heating mode operation or while in defrost control Cooling Mode Operation When the intake air temperature reaches 0.5 C below the setting temp, the compressor and the outdoor fan stop. When it reaches 0.5 C above the setting temp, they start to operate again. Compressor ON Temp Setting Temp+0.5 C Compressor OFF Temp Setting Temp-0.5 C While in compressor running, operating with the airflow speed set by the remote control. While in compressor not running, operating with the low airflow speed regardless of the setting. Healthy Dehumidification Mode When the dehumidification operation input by the remote control is received, the intake air temperature is detected and the setting temp is automatically set according to the intake air temperature. 26 C Intake Air Temp 25 C 24 C Intake Intake Air Temp<26 C Intake Air Temp-1 C 18 C Intake Intake Air Temp<24 C Intake Air Temp-0.5 C Intake Air Temp<18 C 18 C Service Manual 23

Operation Details While in compressor off, the indoor fan repeats low airflow speed and pause. While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification operation and 4-min compressor off repeat. Compressor ON Temp. Setting Temp+0.5 C Compressor OFF Temp. Setting Temp-0.5 C In 10-min dehumidification operation, the indoor fan operates with the low airflow speed. Heating Mode Operation(H/P model) When the intake air temp reaches +3 above the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on. Compressor ON Temp. Setting Temp. Compressor OFF Temp. Setting Temp.+3 C While in compressor on, the indoor fan is off when the indoor pipe temp. is below 20 C, when above 28 C,it operates with the low or setting airflow speed. When the indoor pipe temp is between 20 C and 28 C, it operates with Super-Low(while in sleep mode, with the medium airflow speed). While in compressor off, the indoor fan is off when the indoor pipe temp is below 33 C, when above 35 C,it operates with the low airflow speed. If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the outdoor fan is turned on/off according to the indoor pipe temp. While in defrost control, both of the indoor and outdoor fans are turned off. Defrost Control(H/P model) Defrost operation is controlled by timer and sensing temperature of outdoor pipe. The first defrost starts only when the outdoor pipe temperature falls below -6 C after 45 minutes passed from starting of heating operation and more than 10 minutes operation of compressor. Defrost ends after 9/6 minutes passed from starting of defrost operation or after the outdoor fan operates within max. 2 minutes 30 seconds when the outdoor pipe temperature rises over 12 C even it before 12 minutes. The second defrost starts only when the outdoor pipe temperature falls below -6 C after 45 minutes passed from ending of the first defrost and more than 10 minutes operation of compressor. Heating overload(h/p models) Outdoor fan ON/OFF by sensing outdoor pipe temperature. Outdoor fan is OFF if pipe temperature is over 6.5 C and outdoor fan is ON if pipe temperature is below 0 C. Outdoor fan is off if any one part is heating overload condition. 24 MPS Multi Air Conditioner

Fuzzy Operation (C/O Model) Operation Details According to the temperature set by Fuzzy rule, when the intake air temp is 0.5 C or more below the setting temp, the compressor is turned off. When 0.5 C or more above the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp + 0.5 C Compressor OFF Temp Setting Temp + 0.5 C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 C Intake Air Temp 25 C 24 C Intake Air Temp < 26 C Intake Air Temp + 1 C 22 C Intake Air Temp < 24 C Intake Air Temp + 0.5 C 18 C Intake Air Temp < 22 C Intake Air Temp Intake Air Temp<18 C 18 C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature. Fuzzy Operation (H/P Model) When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since the operation off, the operation mode is selected. When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air temp at that moment as follows. 24 C Inatake Air Temp Fuzzy Operation for Cooling 21 C Inatake Air Temp<24 C Fuzzy Operation for Dehumidification Inatake Air Temp<21 C Fuzzy Operation for Heating If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10 sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated. 1) Fuzzy Operation for Cooling According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5 C or more below the setting temp, the compressor is turned off. When 0.5 C or more above the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp +0.5 C Compressor OFF Temp Setting Temp + 0.5 C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 C Intake Air Temp 25 C 24 C Intake Air Temp<26 C Intake Air Temp + 1 C 22 C Intake Air Temp<24 C Intake Air Temp + 0.5 C 18 C Intake Air Temp<22 C Intake Air Temp Intake Air Temp<18 C 18 C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature. Service Manual 25

Operation Details 2) Fuzzy Operation for Dehumidification According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5 C or more below the setting temp, the compressor is turned off. When 0.5 C or more above the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp + 0.5 C Compressor OFF Temp Setting Temp+0.5 C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 C Intake Air Temp 25 C 24 C Intake Air Temp<26 C Intake Air Temp+1 C 22 C Intake Air Temp<24 C Intake Air Temp+0.5 C 18 C Intake Air Temp<22 C Intake Air Temp Intake Air Temp<18 C 18 C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in dehumidification operation. 3) Fuzzy Operation for Heating According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3 C or more above the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on. Compressor ON Temp Setting Temp Compressor OFF Temp Setting Temp + 3 C At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 20 C Intake Air Temp Intake Air Temp + 0.5 C Intake Air Temp<20 C 20 C When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature automatically according to the Fuzzy rule. While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the intake air temperature and the setting temperature. Airflow Speed Selection The airflow speed of the indoor fan is set to high, medium, low, or chaos (auto) by the input of the airflow speed selection key on the remote control. On-Timer Operation When the set time is reached after the time is input by the remote control, the appliance starts to operate. The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached. If the appliance is operating at the time set by the timer, the operation continues. 26 MPS Multi Air Conditioner

Off-Timer Operation Operation Details When the set time is reached after the time is input by the remote control, the appliance stops operating. The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached. If the appliance is on pause at the time set by the timer, the pause continues. Off-Timer <=> On-Timer Operation When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is carried out according to the set time. Sleep Timer Operation When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appliance operation, the operation of the appliance stops. While the appliance is on pause, the sleep timer mode cannot be input. While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increases by 1 C. After another 30 min elapse, it increases by 1 C again. When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the low. When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the medium. Chaos Swing Mode By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are fixed to the desired direction. While in Chaos Swing mode, the angles of cooling and heating cycle operations are different. Chaos Natural Wind Mode When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the airflow mode is operated for 2~15 sec. randomly by the Chaos Simulation. Jet Cool Mode Operation (C/O Model) If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates. In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation. In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18 C When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority. When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further. Jet Cool Mode Operation (H/P Model) While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated. In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation. In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18 C. When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority. When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then operated in order that the air outflow could reach further. Service Manual 27

Operation Details Auto Restarting Operation When the power is restored after a sudden power failure while in appliance operation, the mode before the power failure is kept on the memory and the appliance automatically operates in the mode on the memory. The slide switch on the main unit of the appliance should be on the Auto Restarting position in order that the Auto Restarting operation is available. Operation Mode that is kept on the memory - State of Operation ON/OFF - Operation Mode/Setting Temp/Selected Airflow Speed - Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour) Forced Operation (C/O Model) FORCED OPERATION AUTO RESTART REMOTE CONTROL Slide Switch To operate the appliance by force in case that the remote control is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions. When the power is supplied while the slide switch is on the forced operation position, or when the slide switch position is switched to the Auto Restarting position (or test operation) or switched from the remote control position to the forced operation position while the power is on, the forced operation is carried out. When the slide switch position is switched from the forced operation position to the Auto Restarting position or the remote control position, the forced operation is canceled and the appliance stops operating. The forced operation is carried out in cooling mode with the setting temperature 22 C and the high speed of airflow. While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to indicate the forced operation. Forced Operation (H/P Model) To operate the appliance by force in case that the remote control is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions. When the power is supplied while the slide switch is on the forced operation position, or when the slide switch position is switched to the Auto Restarting (or test operation) position or switched from the remote control position to the forced operation position while the power is on, the forced operation is carried out. When the slide switch position is switched from the forced operation position to the Auto Restarting position or the remote control position, the forced operation is canceled and the appliance stops operating. The forced operation is carried out in cooling mode with the setting temperature 22 C and the high speed of airflow. In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the operation condition is set according to the intake air temperature as follows. 24 C Intake Air Temp Cooling Mode Operation, 22 C, High Speed 21 C Intake Air Temp<24 C Dehumidification Operation, 23 C, High Speed Intake Air Temp<21 C Heating Mode Operation, 24 C, High Speed While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to indicate the forced operation. 28 MPS Multi Air Conditioner

Operation Details Remote Control Operation Mode When the remote control is selected by the slide switch on the main unit, the appliance operates according to the input by the remote control. Protection of the evaporator pipe from frosting If the indoor pipe temp is below 0 C in 7 min. after the compressor operates without any pause while in cooling cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor evaporator pipe from frosting. When the indoor pipe temp is 7 C or higher after 3 min. pause of the compressor, the compressor and the outdoor fan is turned on according to the condition of the room temperature. Buzzer Sounding Operation When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds. When the appliance-pause key is input by the remote control, the long "beep " sounds. When a key is input by the remote control while the slide switch on the main unit of the appliance is on the forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the remote control signal cannot be received. Service Manual 29

2-way, 3-way Valve 2-way, 3-way Valve 2-way Valve (Liguid Side) 3-way Valve (Gas Side) Flare nut Hexagonal wrench (4mm) Open position Closed position Flare nut Valve cap Open position Closed position Pin To piping connection To outdoor unit To piping connection Service port cap To outdoor unit Service port Works Shaft position Shaft position Service port Shipping Closed Closed Closed (with valve cap) (with valve cap) (with cap) 1. Air purging Open Closed Open (Installation) (counter-clockwise) (clockwise) (push-pin or with vacuum pump) Operation Open Open Closed (with valve cap) (with valve cap) (with cap) 2. 3. 4. 5. 6. Pumping down Closed Open Open (Transfering) (clockwise) (counter-clockwise) (connected manifold gauge) Evacuation Open Open Open (Servicing) (with charging cylinder) Gas charging Open Open Open (Servicing) (with charging cylinder) Pressure check Open Open Open (Servicing) (with charging cylinder) Gas releasing Open Open Open (Servicing) (with charging cylinder) 30 MPS Multi Air Conditioner

2-way, 3-way Valve (1) Pumping down Indoor unit Liquid side 2-Way valve Close Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Close Gas side 3-Way valve Open manifold gauge Lowhandle (CLOSE) Hi- handle (CLOSE) Procedure 1. Confirm that both the gas side and liquid side valves are set to the open position. - Remove the valve stem caps and confirm that the valve stems are in the raised position. - Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the manifold gauge to the service port of the gas side valve. - Connect the hose of the gauge with the push pin to the service port. 4. Air purging of the charge hose. - Open the Low-handle valve on the gauge slightly to air purge from the hose. 5. Set the liquid side valve to the closed position. 6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 1kg/cm 2 g. 7. Immediately set the gas side valve to the closed position. - Do this quickly so that the gauge ends up indicating 1kg/ g. 8. Disconnect the charge set, and mount the liquid side and gas side valve caps and the service port nut. - Use torque wrench to tighten the service port nut to a torque of 1.8kg.m.(4.2kg*m/5.5kg*m) - Be sure to check for gas leakage. Service Manual 31

2-way, 3-way Valve (2) Evacuation (All amount of refrigerant leaked) Indoor unit Liquid side 2-Way valve Open Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Open Gas side 3-Way valve Open manifold gauge Vacuum pump Lowhandle (OPEN) Hi- handle (OPEN) Procedure 1. Confirm that both the liguid side valve and gas side valve are set to the opened position. 2. Connect the vaccum pump to the center hose of the manifold gauge. 3. Connect the service port of the gas side valve to the low side of the gauge. 4. Connect power supply to outdoor unit. 5. Evacuation for approximately one hour. - Confirm that the gauge needle has moved toward-76 cmhg (vacuum of 4 mmhg or less). 6. Close the Low handle of the gauge turn off the vacuum pump, and confirm that the gauge needle does not move(approximately 5 minutes after turning off the vacuum pump). 7. Disconnect the charge hose from the vacuum pump. - Vacuum pump oil. If the vacuum pump oil becomes dirty or depleted,replenish as needed. 8. Mount the valve caps and the service port caps. 32 MPS Multi Air Conditioner

2-way, 3-way Valve (3) Gas Charging (After Evacuation) Indoor unit Liquid side 2-Way valve Open Outdoor unit Gas side 3-Way valve Open Indoor unit Liquid side 2-Way valve Open Gas side 3-Way valve Open Charging cylinder manifold gauge Low-handle (OPEN) Check valve Hi- handle (OPEN) Procedure 1. Connect the gauge to the charging cylinder. - Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. - If you are using a gas cylinder, also use a scale and reverse the cylinder so that the system can be charged with liquid. 2. Purge the air from the charge hose. - Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air. (Be careful of the liquid refrigerant). The procedure is the same if using a gas cylinder. 3. Open the low handle on the gauge and charge the system with liquid refrigerant. - If the system can not be charged with the specified amount of refrigerant, it can be charged with a little at a time (approximately 150g each time) while operating the air conditioner in the cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then repeat the procedure(pumping down-pin). 4. Immediately disconnect the charge hose from the gas side valve's service port. This is different from previous procedures. Because you are charging with liquid refrigerant from the gas side, absolutely do not attempt to charge with larger amounts of liquid refrigerant while operating the air conditioner. - Stopping partway will allow the gas to be discharged. - If the system has been charged with liquid refrigerant while operating the air conditioner turn off the air conditioner before disconnecting the hose. 5. Mount the valve stem nuts and the service port nut. - Use torque wrench to tighten the service port nut to a torque of 1.8 kg.m.(4.2kg.m/5.5kg.m.) - Be sure to check for gas leakage. Service Manual 33

Cycle Troubleshooting Guide Cycle Troubleshooting Guide Trouble analysis 1. Check temperature difference between intake and discharge air and operating current. Temp. Difference Operating Current Temp. difference : approx. 0 C Current : less than 80% of rated current Temp. difference : approx. 8 C Current : less than 80% of rated current Temp. difference : less than 8 C Current : over the rated current All amount of refrigerant leaked out. Check refrigeration cycle. Refrigerant leakage Clog of refrigeration cycle Defective compressor Excessive amount of refrigerant Temp. difference : over 8 C Normal Notice: Temperature difference between intake and discharge air depends on room air humidity. When the room air humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower temperature difference is larger. 2. Check temperature and pressure of refrigeration cycle. Suction pressure Temperature (Compared with (Compared with Cause of Trouble Description the normal value) the normal value) Higher High Defective compressor Current is low. Defective 4-way reverse valve Normal Excessive amount of High pressure does not quickly refrigerant rise at the beginning of operation. Insufficient amount of Lower Higher refrigerant(leakage) Clogging Current is low. Current is low. Notice: 1. The suction pressure is usually 4.5~6.0 kg/cm 2 G at normal condition. 2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with putty. 34 MPS Multi Air Conditioner

Electronic Parts Troubleshooting Guide Electronic Parts Troubleshooting Guide 1. The Outdoor Unit does not operate at all (* Refer to Electronic Control Device drawing and Schematic diagram.) Turn off Main Power (After 10 seconds) Turn on Main Power Does "beeping" sound is made from the Indoor Unit? Check the voltage of power(about AC 220V/AC240V, 60Hz) Main power's voltage Voltage applied to the unit Connecting method of Indoor/Outdoor connecting cable Check Fuse (Outdoor PCB Ass'y) Check Varistor ZNRØ1J(Outdoor PCB Ass'y) NO YES Primarily, the operating condition of Micom is OK. Check each load(indoor/outdoor Fan Motor, Compressor, Stepping Motor etc.) and contacting condition of related connector Check the connection housing for contacting Connector related to CN-DC/AC Display PWB Ass'y Check Items Power Transformer (Outdoor unit) - Input Voltage - Output Voltage IC01D(7812) Output (Indoor/Outdoor unit) IC02D(7805) Output (Indoor/Outdoor unit) IC01A(KIA7036, Reset IC) X01(8MHz) PCB Board Operation Check - About AC220V/240V±10% - Check the power voltage - About AC14±3V DC +12V DC +5V Content Voltage of Micom No. 2, (DC +4.5V over) and Soldering condition. Remedy Replace Trans Replace IC01D Replace IC02D Replace faulty parts Service Manual 35

Electronic Parts Troubleshooting Guide 2. The product is not operate with the remote controller. Turn on Main Power While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped. When the compressor stopped Indoor Fan is driven by a low speed. At this point the wind speed is not controlled by the remote controller. (When operated in the Sleeping Mode, the wind speed is set to the low speed by force.) Cause by the remote control Caused by other parts except the remote control When the mark( battery. ) is displayed in LCD screen, replace Check the contact of CN-DISPI connector. When the detect switch(double key) inside the remote controller door is fault, it is impossible to operate temperature regulating( / ) and wind speed selecting. Check DISP PWB Ass'y - Voltage between CN DISP1 - : DC +5V Check the connecting circuit between the remote controller MICOM (No. )-R17(2Ω)-IRLED-Q1- R16(2.2KΩ). Check point Check the connecting circuit between PIN - R01L(1K) - C01L(680PF) - MICOM PIN Check Receiver Ass'y 36 MPS Multi Air Conditioner

Electronic Parts Troubleshooting Guide 3. When cooling does not operate Turn on Main Power Operate "Cooling Mode( )" by setting the desired temperature of the remote controller is less than one of the indoor temperature by 1 C at least. When in Air Circulation Mode, Compressor/Outdoor Fan is stopped. Check the sensor for indoor temperature is attached as close as to be effected by the temperature of Heat Exchanger(EVA). When the sensor circuit for indoor temperature and connector are in bad connection or are not engaged, Compressor/Outdoor Fan is stopped. Check the related circuit of R02H(12.1K), R01H(1.0K), R04H(6.2K), R03H(1.0K) (Indoor unit). Check the indoor temperature sensor is disconnected or not(about 10kΩ /at 25 C). Check if connection line (Indoor/Outdoor) is complied with Wiring Diagram. Check Outdoor Unit (PCB Ass'y) Good connection Bad connection Correct connection line Service Manual 37

Electronic Parts Troubleshooting Guide 4. When indoor Fan does not operate.(or "ON/OFF" led of display blinks 8 times) Turn off Main power Check it (Indoor/Outdoor)the connection line is complied with Wiring Diagram Bad connection Good connection Correct connection line Check the line fuse in the outdoor unit Check the connection of CN-MOTOR check the operation of blower by manual Check POLY S/W in indoor PCB Ass'y If it is opened If it is shorted Exchange Indoor PCB Ass'y Check the outdoor PCB Ass'y 38 MPS Multi Air Conditioner

Electronic Parts Troubleshooting Guide 5. When Vertical Louver does not operate. Confirm that the Vertical Louver is normally geared with the shaft of Stepping Motor. If the regular torque is detected when rotating the Vertical Louver with hands Normal Check the connecting condition of CN-U/D Connector Check the soldering condition(on PWB) of CN-U/D Connector Check the operating circuit of the Vertical Louver Confirm that there is DC +12V between pin GND. (RED) of CN-U/D and If there are no problems after above checks Confirm the assembly conditions that are catching and interfering parts in the rotation radial of the Vertical Louver Service Manual 39

Electronic Parts Troubleshooting Guide 6. When Heating does not operate Turn ON Main Power Operate Heating Mode( ) by setting the desired temperature of the remote control is higher than one of the indoor temperature by 2 C at least. In heating Mode, the indoor fan operates in case the pipe temperature is higher than 28 C. Check the connector of intake and pipe sensor(thermistors) Check the related circuit of R02H(12.1K), R01H(1.0K), R04H(6.2K), R03H(1.0K). Check the indoor room temperature is disconnected or not (about 10KΩ/at 25 C). Check the indoor pipe temperature is disconnected or not (about 5KΩ/at 25 C). Check if connection line (Indoor/Outdoor) is complied with Wiring Diagram. Check Outdoor Unit (PCB Ass'y) Good connection Bad connection Correct connection line 40 MPS Multi Air Conditioner

Electronic Parts Troubleshooting Guide 7. Outdoor unit does not operate at all. Check Outdoor Unit PCB Board Operation Check in Outdoor Items Power Transformer (Outdoor unit) - Input Voltage - Output Voltage IC01D(7812) Output (Indoor/Outdoor unit) IC02D(7805) Output (Indoor/Outdoor unit) IC01A(KIA7036, Reset IC) X01(8MHz) - About AC220V/240V±10% - Check the power voltage - About AC14±3V DC +12V DC +5V Content Remedy Replace Trans Replace IC01D Replace IC02D Replace faulty parts Turn off Main Power Check the electrical wiring diagram of outdoor side. Check the abnormal condition for the component of Compressor/Outdoor Fan Motor/4-way. Check the open or short of connecting wires between indoor and outdoor. 8. Communication error The control data can be transmitted or received between indoor and outdoor unit with one signal cable. If the data be disturbed by any noise level and misconnection, the unit will be operated incorrectly. In this case, the indoor unit blinks the operation and operation LED on display and indoor fan, outdoor fan, COMP are not operated. The unit can be reoperated by On/Off control of Remocon. Service Manual 41

Installation Installation (1) Installation of Indoor, Outdoor unit 1) Selection of the best location 1. Indoor unit There should not be any heat source or steam near the unit. There should not be any obstacles to prevent the air circulation. A place where air circulation in the room will be good. A place where drainage can be easily obtained. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles. Right More than 5 cm Front Left Rear left Down right Rear right More than 5 cm 2. Outdoor unit If an awning is built over the unit to prevent direct sunlight or rain exposure, be careful that heat radiation from the condenser is not restricted. There should not be any animals or plants which could be affected by hot air discharged. Ensure the spaces indicated by arrows from the wall, ceiling, fence, or other obstacles. More than eye-level more than 30cm (11.8 inch) more than 30cm (11.8 inch) More than 5 cm more than 70cm (27.6 inch) 3. Piping length and the elevation Indoor unit GAS Pipe Size LIQUID Max. piping length A(m) Max. Elevation B(m) A 1/2"(3/8") 1/4" 15 7.5 B Outdoor unit 42 MPS Multi Air Conditioner

Installation 2) Indoor Unit Installation The mounting wall should be strong and solid enough to protect it from the vibration. Installation Plate 1. Mount the installation plate on the wall with four Type "A" screws. (If mounting the unit on the concrete wall, consider using anchor bolts.) Always mount the Installation plate horizontally by aligning the marking-off line by means of the thread and a level. Type "A" screw Weight marking-off line Thread 2. Drill the piping hole with 70mm dia. holecore drill. Line according to the arrows marked on lower the left and the rght side of the Installation Plate. The meeting point of the extended line is the center of the hole. Drill the piping hole at either the right or the left and the hole should be slightly slant to the outdoor side. The lower left and the right side of Installation Plate Left rear piping A A A A Right rear piping ø70mm Indoor Wall ø70mm Outdoor 5~7mm Service Manual 43

Installation (2) Piping and Drainage of Indoor Unit 1) Preparation of pipings 1. Cut the pipes and the cable. Use the accessory piping kit or the pipes purchased locally. Measure the distance between the indoor and the outdoor unit. Cut the pipes a little longer than the measured distance. Cut the cable 1.5m longer than the length of the pipe. Pipe cutter 90 Slanted Rough 2. Remove burrs. Remove burrs from cut edges of pipes. Turn the pipe end toward down to avoid the metal powder entering the pipe. Pipe Reamer Caution: If burrs are not removed, they may cause a gas leakage. Point down 3. Flaring the pipes. Insert the flare nuts, mounted on the connection ports of both indoor and outdoor unit, onto the copper pipes. Some refrgerant gas may leak, when the flare nuts are removed from the indoor unit, as some gas is charged to prevent the inside of the pipe from rusting. Fit the copper pipe end into the Bar of flare tool about 0~0.5mm higher. (See illustration) Flare the pipe ends. 4. Tape the flaring portion to protect it from the dust or damages. "A"; ø12.7 mm (1/2") 0~0.5 mm ø9.52 mm (3/8") 0~0.5 mm ø6.35 mm (1/4") 0~0.5 mm Bar "A" Bar Handle Yoke Cone Copper pipe Clamp handle Red arrow mark = Improper flaring = Inclined Surface Cracked Uneven damaged thickness When properly flared, the internal surface flare will evenly shine and be of even thickness. Since the flare part comes into contact with the connectors, carefully check the flare finish. 44 MPS Multi Air Conditioner

Installation 2) Connection of Pipings 1. Remove the installation plate Pull the two ' ' marked portion of bottom of the chassis and pull the installation plate out of chassis. Installation plate Pull 2. Route the drain hose and the indoor tubing. Pull For left rear piping 3. Route the tubing and the drain hose straight backwards(see figure). 4. Insert the connecting cable into the indoor unit through the piping hole. Do not connect the cable to the indoor unit. Make a small loop with the cable for easy connection later. Tubing holder To remove the holder, press the bottom of the chassis near the holder upwards and the tab is clear of its hole. Turn it clockwise approx. 90 and remove it. Press 5. Tape the tubing, drain hose and the connecting cable. Be sure that drain hose locates at the lowest side of the bundle. Locating at the upper side can be a reason that drain water overflows drain pan inside the unit. Gas side piping Connecting cable Liquid side piping Drain hose Service Manual 45

Installation 6. Indoor unit installation. Hook the indoor unit onto the upper position of the installation plate. (Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure the hooks are properly seated on the installation plate by moving it in left and right. Connecting cable Drain hose Press the lower left and right side of the unit against the Installation Plate until the hooks engage with their slots (sound click). 7. Connecting the pipings to the indoor unit. Align the center of the pipings and sufficiently tighten the flare nut with fingers. Finally, tighten the flare nut with torque wrench until the wrench clicks. Wrench tightening the flare nut with forque wrench, ensure the direction for tightening follows the arrows on the wrench. Indoor unit tubing Flare nut Pipings Pipe Size Torque Liquid Side (1/4") 1.8kg m Gas Side (3/8") Gas Side (1/2") 4.2kg m 5.5kg m Spanner Torque wrench 8. Wrap the insulation material around the connecting portion. CAUTION: Take care to arrange the pipings, drain hose and cables as the right upper picture for inserting it into the indoor unit and refixing the tubing holder easily. Plastic bands Insulation material Wrap the insulation material around the connecting portion. 46 MPS Multi Air Conditioner

Installation 9. Set the pipings and the connecting cable to the back of the chassis with the tubing holder. Hook the edge of tubing holder to tap on chassis and push the bottom of tubing holder to be engaged in the bottom of chassis. Piping Taping Drain hose Tubing holder 1 Hook 2 Push 10. Indoor unit installation. Hook the indoor unit onto the upper portion of installation plate. (Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.) Ensure the hooks are properly seated on the installation plate by moving it in left and right. Connecting cable Drain hose Press the lower left and right side of the unit against the Installation Plate until the hooks engages with their slots (sound click). Service Manual 47

Installation (3) Connecting Pipings and the cable to Outdoor unit 1) Connecting the pipings to the Outdoor unit 1. Align the center of the pipings and sufficiently tighten the flare nut with fingers. 2. Finally, tighten the flare nut with torque wrench until the wrench clicks. When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Pipe Size Liquid Side (1/4") Gas Side (3/8") Gas Side (1/2") Torque 1.8kg.m 4.2kg.m 5.5kg.m Outdoor unit A A-UNIT Gas side piping B-UNIT Evaporator side piping B C Torque wrench C-UNIT Gas side piping Evaporator side piping 48 MPS Multi Air Conditioner

Installation Connection of the cable 1. Remove the cover control from the unit by loosening the screw. Outdoor unit Terminal block Over 5mm L1 L2 C A-UNIT G V S C B-UNIT G V S C C-UNIT G V S Holder for power supply cord Power Source 208/230V AC (High voltage) Connecting cable(low voltage) Power supply cable C G V S Terminal BLOCK Indoor A-UNIT C G V S Terminal BLOCK Indoor B-UNIT C G V S Terminal BLOCK Indoor C-UNIT Cover control Connecting cable 2. Dismount caps on the conduit panel. 3. Temporarily mount the conduit tubes on the conduit panel. 4. Connect the wires to the terminals on the control board individually as the following. 5. Secure the cable onto the control board with the holder (clamper). 6. Ground the unit in accordance with local codes. 7. Refix the cover control to the original position with the screw. 8. Use lock nuts to secure the conduit tubes. CAUTION The power cable connected to the outdoor unit should be complied with the following specifications. (UL recognized and CSA certified) AWG 12 NOTE 1. Separately wire the high and low voltage line. 2. Use heat-proof electrical wiring capable of withstanding temperature up to 167 F. 3. Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit. (For example, Type SJO-WA) GN/YL 20mm The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications. (UL recognized and CSA certified) WARNING Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size of wire and wiring method, etc). Every wire must be connected firmly. No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts. GN/YL AWG 18 20mm Service Manual 49

Installation Connection method of the connecting cable(example) (1) Dismount two-caps on the conduit panel. (2) Make a hole appropriate for the passage of connection cable through on cap by tool. (for low voltage line) (3) Pass the connecting cable through the hole. (4) Properly connect the cable on the terminal block. (5) Fix the connection cable with clamp cord provided on the unit not to have strain at the terminal when the connection cable is pulled outside up to a 35 pound weight. (6) Wind the vinyl tape round the connecting cable for sealing between the surface of the connection cable and cap. (7) Mount the taped part of cable on the cap. (8) Finally, mount the holed cap with the wound cable on the conduit panel. Lock nut Power supply line (1ø, 230/208V) G Conduit panel High voltage Terminal block Clamp cord Cap(Reuse) Hole (for low voltage line) Cap(Remove) Taping (for sealing) Low voltage line (connecting cable) WARNING Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow instructions "How to connect wiring to the terminals" and fasten the wire tightly with the fixing screw of the terminal plate. How to connect wiring to the terminals For solid core wiring (or F-cable) (1) Cut the wire end with a wire cutter of wire-cutting pliers, then strip the insulation to expose the solid wire about 25mm(15/16") (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using pliers, bend the solid wire to from a loop suitable for the terminal screw. (4) Shape the loop wire properly, place it on the terminal plater and tighten securely with the terminal screw using a screwdriver. For strand wiring (1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation to expose the strand wiring about 10mm(3/8"). (2) Using a screwdriver, remove the terminal screw(s) on the terminal plate. (3) Using a round terminal fastener or pliers, securely clamp each stripped wire end with a round terminal. (4) Position the round terminal wire, and replace and tighten the terminal screw using a screwdriver. Strip 25mm(15/16") Strip 10mm(3/8") Loosening the terminal block screw Connecting cable Solid wire Insulation Strand wire Low voltage Fastening the wire tightly Loop Round terminal 50 MPS Multi Air Conditioner

Installation CAUTION If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below. Main power source Air Conditioner Circuit Breaker Use a circuit breaker or time delay fuse. Model Power source Fuse or breaker Capacity 18k 1ø,230/208V 15A 24k 1ø,230/208V 20A 36k 1ø,230/208V 30A Connect the cable to the indoor unit 1. Connect the wires to the terminals on the control board individually according to the outdoor unit connection. Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively. (Refer to Wiring diagram on page11.) WARNING Be sure to refer to the wiring diagram label inside the cover control and carry out the correct field wiring. Wrong wiring can cause the unit to misoperate to result in a fire hazard. Check local electrical codes and any specified wiring instructions or limitations. Connecting cable 2. Attach the Grille onto the cabinet. Grasp lower the left and right side of the Grille and engage four tabs on the top inside edge of the chassis. Press the Grille toward the chassis until it will be back into place. Service Manual 51

Installation (4) Checking the drainage (5) Form the piping 1. To remove the front panel from the indoor unit, remove the front panel from the indoor unit cabinet. Set the air direction louvers up-and-down to the position(horizontally) by hand. Remove the securing screws that retain the front panel. Pull the lower left and right sides of the grille toward you and lift it off. (9K Btu models: 2EA, 12K Btu models: 3EA) Pull the right and the left side. Screw 2. To check the drainage. Pour a glass of water on the evaporator. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. 1. Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. 2. In cases where the outdoor unit is installed below the indoor unit perform the following. Tape the piping, drain hose and connecting cable from down to up. Secure the tapped piping along the exterior wall using saddle or equivalent Seal a small opening around the pipings with gum type sealer. Taping Drain hose Plastic band Pipings Connecting cable Power supply cord Trap is required to prevent water from entering into electrical parts. 3. Drain piping The drain hose should point downward for easy drain flow. Do not make drain piping. Downward slope 3. In cases where the Outdoor unit is installed above the Indoor unit perform the following. Tape the piping and connecting cable from down to up. Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room. Fix the piping onto the wall by saddle or equivalent. Seal a small opening around the pipings with gum type sealer. Trap Do not raise Accumulated drain water Air Tip of drain hose dipped in water Less than 50mm gap Water leakage Water leakage Waving Water leakage Ditch Trap 52 MPS Multi Air Conditioner

Installation (6) Air Purging of the Pipings and indoor unit The air which contains moisture remaining in the is refrigeration cycle may cause a malfunction on the compressor. 1. Confirm that both the liquid side valve and the gas side valve are set to the closed position. 2. After connecting the piping, check the joints for gas leakage with gas leak detector. 3. Remove the service port nut, and connect the gauge manifold and the vacuum pump to the service port by the charge hose. 4. Vacuum the indoor unit and the connecting pipes until the pressure in them lowers to below-76cmhg. 5. Disconnect the charge hose and fit the nut to the service port. (Tightening torque: 1.8kg.m) 6. Remove the valve stem nuts, and fully open the stems of the 2-way and 3-way valves with a hexagon wrench. 7. Tighten the valve stem nuts of the 2-way valve and 3-way valve. Indoor unit Liquid side 2-Way valve Closed Outdoor unit Gas side 3-Way valve Closed Indoor unit Liquid side 2-Way valve Closed Gas side 3-Way valve Closed manifold gauge Vacuum pump Lowhandle (OPEN) Hi- handle (OPEN) Service Manual 53

Installation (7) Maximum Length of Pipe and Freon Extra Charge Multi Piping Type Capacity(Btu/h) 36k Indoor Capacity (Btu/h) Max total length of all pipes (A+B+C) Max length of each pipe (A/B/C) Min length of each pipe (A/B/C) Max Elevation between each indoor unit and Max elevation between indoor units (h2) outdoor unit (h1) 45m 15m 3m 7.5m 7.5m (150ft) (50ft) (10ft) (25ft) (25ft) 12K 1/2" 1/4" Pipe Size Gas Liquid Standard Length Additional Refrigerant 7.5m 30g/m (25ft) (0.32oz/ft) A h2 h1 h1 h2 h1 Oil trap B C CAUTION: Capacity is based on standard length and maximum allowance length is on the basis of reliability. Oil trap should be installed every 5~7 meters (16.4~23.0ft). 54 MPS Multi Air Conditioner

Installation (8) Test running 1) Connection of power supply 1. Connect the power supply cord to the independent power supply. 2. Prepare the remote control. Insert two batteries provided. Remove the battery cover from the remote controller. Slide the cover according to the arrow direction. Insert the two batteries. (Two "R03" or "AAA" dry-cell batteries or equivalent.) Be sure that the (+) and (-) directions are correct. Be sure that both batteries are new. Re-attach the cover. Slide it back into position. 3. Operate the unit at cooling operation mode for fifteen minutes or more. Battery Cover Settlement of Outdoor Unit Bolt Anchor the outdoor unit with a bolt and nut (ø10cm) tightly and horizontally on a concrete or rigid mount. When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. In the case when the vibration of the unit is conveyed to the house, settle the unit with an antivibration rubber. Tubing connection 2) Evaluation of the performance 1. Measure the temperature of the intake and discharge air. 2. Ensure the difference between the intake temperature and the discharge one is more than 8 C. NOTICE : Heating capacity decreases as outdoor temperature decreases. The unit can work below to 14F without unit out or system shut down. Discharge air Service Manual 55

Operation Operation (1) Name and Function-Remote Control (Door Closed) REMOTE CONTROL Signal transmitter Transmits the signals to the room air conditioner. Signal transmitter 1 START/STOP BUTTON Operationstartswhenthisbuttonispressedandstops when the button is pressed again. 2 OPERATION MODE SELECTION BUTTON Used to select the operation mode. 5 4 6 1 3 3 4 ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high, or CHAOS. 2 Flip-up door (closed) 5 JET COOL Used to start or stop the speed cooling. (Speed cooling operates super high fan speed in cooling mode.) 6 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. 56 MPS Multi Air Conditioner

Operation (2) Name and Function-Remote Control (Door Opened) REMOTE CONTROL Signal transmitter Transmits the signals to the room air conditioner. Signal transmitter 1 2 3 ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. TIME SETTING BUTTONS Used to adjust the time. TIMER SET/CANCEL BUTTONS Used to set the timer when the desired time is obtained and to cancel the Timer operation. 4 SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. 1 2 3 ON SET OFF CANCEL C/ F 4 5 6 7 8 5 6 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating (turns indoor fan on/off). ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 7 C TO F SWITCHING BUTTON 8 RESET BUTTON Used prior to resetting time or after replacing batteries. Service Manual 57

Disassembly of the parts (Indoor unit) Disassembly of the parts (Indoor unit) Warning : Disconnect the unit from power supply before making any checks. Be sure the power switch is set to OFF. To remove the Grille from the Chassis. Set the up-and-down air discharge louver to open position (horizontally) by finger pressure. Remove the securing screws To remove the Grille, pull the lower left and right side of the grille toward you (slightly tilted) and lift it straight upward. Screw 1. To remove the sensor, housing connect, step motor conductor with sensor holder, Motor, Evaporator & P.C.B. Motor Conductor Sensor Conductor Step Motor Conductor 58 MPS Multi Air Conditioner

Disassembly of the parts (Indoor unit) 2. To remove the Control Box. Remove securing screws. Pull the control box out from the chassis carefully. 3. To remove the Discharge Grille. Pull the discharge grille out from the chassis carefully. 4. To remove the Evaporator. Remove screws securing the evaporator and the holder eva. Unhook the tab on the right inside of the chassis at the same time, slightly pull the evaporator toward you until the tab is clear of the slot. 5. To remove the Cross-Flow Fan Loosen the screw securing the cross-flow fan to the fan motor (do not remove). Lift up the right side of the cross-flow fan and the fan motor, separate the fan motor from the cross-flow fan. Remove the left end of the cross-flow fan from the self-aligning bearing. Service Manual 59

Exploded View and Replacement Parts List Exploded View and Replacement Parts List 1. Indoor Unit L3-C363LA0/C363MA0/C363NA0, L3-H363LA0/H363MA0/H363NA0 268711-1 267110 135311 135316 135314 152302 152313 354210 147581 135500 359011 342800 146811 249951 131410 733010 35211B 346810 352150 567480-1 268711-2 567480-2 60 MPS Multi Air Conditioner

Exploded View and Replacement Parts List PartsList-IndoorUnit LOCATION PART No. SVC DESCRIPTION No. L3-C363LA0 L3-C363MA0 L3-C363NA0 L3-H363LA0 L3-H363MA0 L3-H363NA0 CODE 131410 CHASSIS ASSEMBLY 3141A20003D 3141A20003D 3141A20003D 3141A20003D 3141A20003D 3141A20003D R 135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR)3531A10023X 3531A10023X 3531A10023X 3531A10023X 3531A10023X 3531A10023X R 135312 GRILLE ASSEMBLY, FRONT 3531A10098B 3531A10098B 3531A10098B 3531A10098A 3531A10098A 3531A10098A R 135500 COVER 3550A10107A 3550A10107A 3550A10107A 3550A10107A 3550A10107A 3550A10107A R 146811 MOTOR ASSEMBLY, STEP 4681AR2727H 4681AR2727H 4681AR2727H 4681AR2727H 4681AR2727H 4681AR2727H R 152302 FILTER(MECH), A/C 5230A20004A 5230A20004A 5230A20004A 5230A20004A 5230A20004A 5230A20004A R 152313 DEODORIZER 5231AR2412T - - 5231AR2412T - - Only in CND/Not in RMC 159901 VANE,HORIZONTAL 5990A30007A 5990A30007A 5990A30007A 5990A30007A 5990A30007A 5990A30007A R 249951 CONTROL BOX ASSEMBLY, INDOOR 4995A00003A 4995A00003A 4995A00003A 4995A00003A 4995A00003A 4995A00003A R 263230-1 THERMISTOR ASSEMBLY 6323A20003A 6323A20003A 6323A20003A 6323A20003A 6323A20003A 6323A20003A R 263230-2 THERMISTOR ASSEMBLY 6323A20024A 6323A20024A 6323A20024A 6323A20024A 6323A20024A 6323A20024A R 267110 REMOTE CONTROLLER ASSEMBLY 6711A20025N 6711A20025N 6711A20025N 6711A20026U 6711A20026U 6711A20026U R 268712 PWB(PCB) ASSEMBLY, DISPLAY 6871A30009Q 6871A30009Q 6871A30009Q 6871A30009Q 6871A30009Q 6871A30009Q R 268714 PWB(PCB) ASSEMBLY, MAIN 6871A20502B 6871A20502B 6871A20502B 6871A20502A 6871A20502A 6871A20502A R 342800 BEARING 3H02821B 3H02821B 3H02821B 3H02821B 3H02821B 3H02821B R 346812 MOTOR ASSEMBLY, DC 4681AR2295H 4681AR2295H 4681AR2295H 4681AR2295H 4681AR2295H 4681AR2295H R 35211B TUBE ASSEMBLY, TUBING 2H02449J 2H02449J 2H02449J 2H02449J 2H02449J 2H02449J R 352150 HOSE ASSEMBLY, DRAIN 5251AR2575H 5251AR2575H 5251AR2575H 5251AR2575H 5251AR2575H 5251AR2575H R 354210 EVAPORATOR ASSEMBLY, FIRST 5421A20032D 5421A20032D 5421A20032D 5421A20032D 5421A20032D 5421A20032D R 359011 FAN ASSEMBLY, CROSS FLOW 5901AR6141C 5901AR6141C 5901AR6141C 5901AR6141C 5901AR6141C 5901AR6141C R 733010 PLATE ASSEMBLY, INSTALL 1H00843A 1H00843A 1H00843A 1H00843A 1H00843A 1H00843A R 135314 GRILLE ASSY,INLET SUB 3531A10054R 3531A10054R 3531A10054R 3531A10054Q 3531A10054Q 3531A10054Q R Service Manual 61

Exploded View and Replacement Parts List 2. Outdoor Unit L3UC363LA0, L3UC363MA0, L3UC363NA0 437211 435301 552117 435512 548490 552112 559010 552113 546810 447910 430410 649950 567480-4 W0CZZ-1 554160-1 554031 137213-1 135314 567480-5 W0CZZ-2 268711-3 268711-6 567502 661400 661400 661400 554160-2 137213-2 435511 552203-1 552203-2 62 MPS Multi Air Conditioner

Exploded View and Replacement Parts List Parts List - Outdoor Unit(L3UC363LA0, L3UC363MA0, L3UC363NA0) LOCATION No. DESCRIPTION PART No. L3-C363LA0 L3-C363MA0 L3-C363NA0 135301 GRILLE,DISCHARGE 3530A20006B 3530A20006B 3530A20006B R 435300 GRILLE,REAR 3530A10176B 3530A10176B 3530A10176B R 263230-1 THERMISTOR ASSEMBLY 6323A20028A 6323A20028A 6323A20028A R 263230-2 THERMISTOR ASSEMBLY 6323A20026A 6323A20026A 6323A20026A R 430410 BASE ASSEMBLY, OUTDOOR 3041AP7177D 3041AP7177D 3041AP7177D R 435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 3551A10044B 3551A10044B 3551A10044B R 435512 COVER ASSEMBLY,TOP(OUTDOOR) 3H03266H 3H03266H 3H03266H R 437211 PANEL ASSEMBLY,FRONT(OUTDOOR) 3721A10109A 3721A10109A 3721A10109A R 447910 BARRIER ASSEMBLY,OUTDOOR 4791A10019B 4791A10019B 4791A10019B R 546810 MOTOR ASSEMBLY,OUTDOOR 4681AR1392X 4681AR1392X 4681AR1392X R 548490 ACCUMULATOR ASSEMBLY(MECH) 5211A21233B 5211A21233B 5211A21233B R 552112 TUBE ASSEMBLY,CONDENSER IN 5211A11010C 5211A11010C 5211A11010C R 552113 TUBE ASSEMBLY, CONDENSER OUT 5211A12001C 5211A12001C 5211A12001C R 552116 TUBE ASSEMBLY, REVERSING - - - R 552117 TUBE ASSEMBLY, SUCTION(OUTDOOR) 5211A10446C 5211A10446C 5211A10446C R 554031 CONDENSER ASSEMBLY, BENT 5403A20168C 5403A20168C 5403A20168C R 559010 FAN ASSEMBLY, PROPELLER 5901A10033A 5901A10033A 5901A10033A R 561410-1 COIL ASSEMBLY, REVERSING VALVE - - - R 561410-2 COIL ASSEMBLY, SOLENOID - - - R 649950 CONTROL BOX ASSEMBLY,OUTDOOR 4995A00002B 4995A00002B 4995A00002B R 668711-1 PWB(PCB) ASSEMBLY,MAIN(AC) 6871A20500B 6871A20500B 6871A20500B R 668711-2 PWB(PCB) ASSEMBLY,MAIN(OUTDOOR) 6871A20479B 6871A20479B 6871A20479B R 137213-1 PANEL ASSEMBLY, SIDE 3721A10110A 3721A10110A 3721A10110A R 137213-2 PANEL ASSEMBLY, SIDE 3721A10111C 3721A10111C 3721A10111C R 552203-1 VALVE,SERVICE 2H01890U 2H01890U 2H01890U R 552203-2 VALVE,SERVICE 2H02479R 2H02479R 2H02479R R 554160-1 COMPRESSOR 2520UHGK2EA 2520UHGK2EA 2520UHGK2EA R 554160-2 COMPRESSOR 2520UMMK2BA 2520UMMK2BA 2520UMMK2BA R 561411-1 COIL ASSEMBLY,EXPANSION 6141A20018D 6141A20018D 6141A20018D R 561411-2 COIL ASSEMBLY,EXPANSION 6141A20018E 6141A20018E 6141A20018E R 561411-3 COIL ASSEMBLY,EXPANSION 6141A20018F 6141A20018F 6141A20018F R W0CZZ-1 CAPACITOR,DRAWING 0CZZA20007Q 0CZZA20007Q 0CZZA20007Q R W0CZZ-2 CAPACITOR,DRAWING 2H01451S 2H01451S 2H01451S R 567502 O.L.P 2H00599W 2H00599W 2H00599W R SVC CODE Service Manual 63

Exploded View and Replacement Parts List L3UH363LA0, L3UH363MA0, L3UH363NA0 135301 552116 435512 55211F 548490 552112 559010 437211 552113 546810 447910 430410 649950 263230-2 W0CZZ-1 554160-1 554031 137213-1 135314 263230-1 W0CZZ-2 668711-2 668711-1 567502 554160-2 137213-2 435511 561410-1 561410-2 561411-1 561411-2 561411-3 552203-1 552203-2 64 MPS Multi Air Conditioner

Exploded View and Replacement Parts List Parts List - Outdoor Unit(L3UH363LA0, L3UH363MA0, L3UH363NA0) LOCATION PART No. SVC DESCRIPTION No. L3-H363LA0 L3-H363MA0 L3-H363NA0 CODE 135301 GRILLE,DISCHARGE 3530A20006B 3530A20006B 3530A20006B R 135314 GRILLE,REAR 3530A10176B 3530A10176B 3530A10176B R 263230-1 THERMISTOR ASSEMBLY 6323A20028A 6323A20028A 6323A20028A R 263230-2 THERMISTOR ASSEMBLY 6323A20026A 6323A20026A 6323A20026A R 430410 BASE ASSEMBLY, OUTDOOR 3041AP7177D 3041AP7177D 3041AP7177D R 435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 3551A10044A 3551A10044A 3551A10044A R 435512 COVER ASSEMBLY,TOP(OUTDOOR) 3H03266H 3H03266H 3H03266H R 437211 PANEL ASSEMBLY,FRONT(OUTDOOR) 3721A10109A 3721A10109A 3721A10109A R 447910 BARRIER ASSEMBLY,OUTDOOR 4791A10019B 4791A10019B 4791A10019B R 546810 MOTOR ASSEMBLY,OUTDOOR 4681AR1392X 4681AR1392X 4681AR1392X R 548490 ACCUMULATOR ASSEMBLY(MECH) 5211A21233A 5211A21233A 5211A21233A R 552112 TUBE ASSEMBLY,CONDENSER IN 5211A11010C 5211A11010C 5211A11010C R 552113 TUBE ASSEMBLY, CONDENSER OUT 5211A12001C 5211A12001C 5211A12001C R 552116 TUBE ASSEMBLY, REVERSING 5211A10448A 5211A10448A 5211A10448A R 552117 TUBE ASSEMBLY, SUCTION(OUTDOOR) - - - R 554031 CONDENSER ASSEMBLY, BENT 5403A20168A 5403A20168A 5403A20168A R 559010 FAN ASSEMBLY, PROPELLER 5901A10033A 5901A10033A 5901A10033A R 561410-1 COIL ASSEMBLY, REVERSING VALVE 6141A20021A 6141A20021A 6141A20021A R 561410-2 COIL ASSEMBLY, SOLENOID 6141A20022A 6141A20022A 6141A20022A R 649950 CONTROL BOX ASSEMBLY,OUTDOOR 4995A00002A 4995A00002A 4995A00002A R 668711-1 PWB(PCB) ASSEMBLY,MAIN(AC) 6871A20500B 6871A20500B 6871A20500B R 668711-2 PWB(PCB) ASSEMBLY,MAIN(OUTDOOR) 6871A20479A 6871A20479A 6871A20479A R 137213-1 PANEL ASSEMBLY, SIDE 3721A10110A 3721A10110A 3721A10110A R 137213-2 PANEL ASSEMBLY, SIDE 3721A10111C 3721A10111C 3721A10111C R 552203-1 VALVE,SERVICE 2H01890U 2H01890U 2H01890U R 552203-2 VALVE,SERVICE 2H02479R 2H02479R 2H02479R R 554160-1 COMPRESSOR 2520UHGK2EA 2520UHGK2EA 2520UHGK2EA R 554160-2 COMPRESSOR 2520UMMK2BA 2520UMMK2BA 2520UMMK2BA R 561411-1 COIL ASSEMBLY,EXPANSION 6141A20018D 6141A20018D 6141A20018D R 561411-2 COIL ASSEMBLY,EXPANSION 6141A20018E 6141A20018E 6141A20018E R 561411-3 COIL ASSEMBLY,EXPANSION 6141A20018F 6141A20018F 6141A20018F R W0CZZ-1 CAPACITOR,DRAWING 0CZZA20007Q 0CZZA20007Q 0CZZA20007Q R W0CZZ-2 CAPACITOR,DRAWING 2H01451S 2H01451S 2H01451S R 567502 O.L.P 2H00599W 2H00599W 2H00599W R 55211F TUBE ASSEMBLY, SOLENOIDE 5211A00007A 5211A00007A 5211A00007A R Service Manual 65

P/No.: 3828A20466A August, 2004 Printed in Korea