RFQ # PR5006805 Replace Kitchen Equipment in the CGR



Similar documents
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Schedule of Maintenance Fees

city of edmonds development information

Irvinton Village Apartments 2901 Fulton Houston, Texas Houston Housing Authority J. Allen Management Managing Agent

You can do it all yourself. But you don t have to.

Cooktop Low-Profile Ventilation Hoods

SECTION GENERAL PROVISIONS FOR HVAC WORK

SECTION MORTUARY REFRIGERATORS

Self-Home Inspection Checklist

Gramercy Place Condo Association, Inc.

IH E Sigma Island 90

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Kitchen & Bath Measurements Guide

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Orlando Home Inspection Services

Summit Series Single Section and Double Section Homes

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

All bidders shall indicate in their bid/proposal that this Addendum has been received and considered in their bid proposal.

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

A.C.E. Home Inspection Service St. Peters, MO (636)

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

COMPREHENSIVE PROPERTY INSPECTIONS

IMPROVEMENT COST ESTIMATE powered by HomeFixers

HOMEOWNER MAINTENANCE MANUAL

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

HOMEOWNER S PERMIT GUIDE

Cleaning Guidelines Range Refrigerators Dishwasher Kitchen Exhaust Fans Cabinets and Drawers Plumbing Fixtures Light Fixtures

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

Home Maintenance Checklist

Base Cabinet with Self-storing Folding Doors and Floor

GenStore Archive Cabinet

Home Inspection Report

The UPLANDS at ORO VALLEY Sterling Features

FINAL December 2012 SECTION DUCTWORK

Element D Services Heating, Ventilating, and Air Conditioning

CONDITION OF QUALITY ITEMS

Inspecton Report. Property Address:

KITCHEN HOODS GUIDELINES

Does Wall Township require an inspection by the building department on resale of a home?

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Safe Method: Gas Safety in Catering Establishments

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

SUMMARY OF WORK FOR GENERAL CONTRACTOR

8629 S. Kimbark, Chicago, IL PROJECT SPECIFIC SCOPE:

Cuyahoga County Urban Mold & Moisture Project

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Inspection Item COMMENTS

*PLEASE RETURN THIS FORM TO THE RENTAL OFFICE*

I NI NP R Inspected Items

Inspection Tech. (330) Inspected By: Aaron Westerburg

220.5" Basic Features. Electrical Features

Rehab Inspection Report Page 1

ADDENDUM NO. 1. DATE: February 10, 2015 INVITATION FOR BID: IFB K Commerce Road Renovations Project DATED: February 9, 2015

TruexCullins Architecture Fairfield Center School Bid Documents Kitchen and Bathroom Renovation March 1, 2015

What I will cover: Cuyahoga County Urban Mold & Moisture Project. Mold & moisture problems. Mold and moisture problems. Mold & moisture problems

OPEN ITEMS LIST - CONSTRUCTION Project Name: East Central Middle School - Jackson County CLA#: 11003

PLAN SUBMITTAL INFORMATION

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Preventing Ice Dams on Roofs

Hartsfield-Jackson Atlanta International Airport s

Building Condition Assessment Report

Total Home Inspection Checklist

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

South Carolina Home Inspector Standards of Practice

New Home Walk-Through Package

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

Estimating Database Checklist

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

Fire Damage. To Help Prevent. a Guide

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

HOUSING QUALITY STANDARDS (HQS)

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Commercial Kitchen Fire Safety

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Home Inspection Report

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Crawford Inspection Services C.C.B. #

HomeTech Kitchen & Bath Cost Estimator

Transcription:

RFQ # PR5006805 Replace Kitchen Equipment in the CGR GENERAL The Consulate General of the United States of America has a requirement to furnish and install new kitchen equipment at the Consul General s Residence, located on 18 Agron Road, per the below scope of work. Direct any questions regarding this RFQ to Procurement by email at Procurement@state.gov. STATEMENT OF WORK The US Consulate General seeks contractors to furnish and install new kitchen equipment in the CGR on Agron Road in. The Contractor will perform the following work: Remove the existing kitchen hood, fan, & exhaust ductwork Remove 2 gas kitchen ovens/stoves Remove 2 dishwashers Install new kitchen hood, exhaust fan, supply/return duct, makeup hood Install 1 new commercial gas stove and electrical oven Install 2 new commercial dishwasher Demo 1. The Contractor will remove the kitchen hood, fan, exhaust duct, 2 stoves, and 2 dishwashers. All items should be removed from the site the same day. Demo ed items are not to be stored on site. 2. The Contractor must coordinate equipment demo with GSO Warehouse. Some equipment may need to be delivered to the GSO Warehouse in Talpiot for demo. 3. The Contractor is responsible for the demo of all electrical, plumbing, gas, etc 4. If any walls, floor, countertops, doors, etc are damaged during the demo the Contractor must repair those items to the original condition. 5. The Contractor must fully sweep and wipe down the kitchen after the demo. Equipment Specs 1. Kitchen Hood (exhaust only) Stainless steel construction Wall mounted / canopy type Stainless steel removable filters, grease trough, grease capture cup Stainless steel backsplash fully covering the exposed wall behind the stove. Integrated light fixture Integrated on/off switch for the light and an integrated on/off switch for the exhaust fan

2. Wall Mounted Exhaust fan Wall sleeve & factory curb Grease drain pointed down at installation Factory gravity damper Electrical disconnect switch 3. Exhaust duct Double wall, stainless steel Super Wool 607 Plus insulation or local equivalent in between the metal layers Duct should be sloped to prevent grease accumulation in the ductwork. 4. Range Stainless steel construction Minimum 8 gas burners with lift off heads Two electric stoves with at least 4 rack positions (racks included) All knobs and controls to be front mounted Range should be wheel mounted 5. Dishwasher Stainless steel construction Removable rack system (provide 8 racks) Installation Notes 1. Kitchen Hood (exhaust only) The contractor must provide a fully dimensioned shop drawing (plan and section view) of all equipment in this contract. The drawing must also show coordination with the countertops, walls, ceiling, and the new stove. The Contractor must show the appropriate hood overhang and mounting height with documentation from the equipment vendor that the mounting height and overhang are appropriate. The Contractor is responsible for all electrical, gas piping, gas regulator, valves, drains, gas train, wall cutting and patching, paint touch up, and blocking the existing chimney. 2. Wall Mounted Exhaust fan The Contractor is responsible for all wall cutting and patching, electrical, drains, etc Wall penetrations must be sealed for water and must be done neatly and professionally. 3. Exhaust duct Ductwork must be sloped to prevent grease buildup in the duct The duct penetration must be sealed and protected as required by local codes for grease duct. 4. Range The Contractor is responsible for all electrical, gas, regulators, plumbing, mounting, cutting, patching required for a professional installation.

The range should fit into the height, width, and depth of the existing range as closely as possible. The Consulate has the right to reject a range that sticks out too far or requires modification of the countertops. If the approved range requires the countertops or cabinets to be modified, the Contractor must include that modification in their price. Cutting the counters or cabinets must be done professionally and neatly with new or replacement trim as needed or as determined by the US Consulate. Any wall penetrations must be appropriately sealed to prevent moisture infiltration and meet local codes. 5. Dishwasher The Contractor is responsible for all electrical, plumbing, drains, mounting, cutting, patching required for a professional installation. The dishwasher should fit into the height, width, and depth of the existing range as closely as possible. The Consulate has the right to reject a range that sticks out too far or requires modification of the countertops or cabinets. If the approved dishwasher requires the countertops or cabinets to be modified, the Contractor must include that modification in their price. Cutting the counters or cabinets must be done professionally and neatly with new or replacement trim as needed or as determined by the US Consulate. Any wall penetrations must be appropriately sealed to prevent moisture infiltration and meet local codes. NOTES The Contractor must sweep up all debris and dust and remove from the site each day. Work is to take place 5 day per week 9am 4pm. Work must be completed within 1 month of the notice to proceed. The Contractor is responsible for all ladders, tools, materials. Contractors must use proper PPE and hold a permit for working from heights and electrical. Bids are due XXX The Contractor must list the cost of each piece of equipment with separate installation pricing. The USG will not provide any tools, paint, materials, etc... for this project. The Contractor must provide the following submittals within 10 days of receipt of the NTP: Equipment submittals and fully dimensioned shop drawings.

#END OF SOW#