Refrigeration and Air Conditioning with Reduced Environmental Impact



Similar documents
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

7. COST AND EMISSION REDUCTION ANALYSIS OF HFC EMISSIONS FROM REFRIGERATION AND AIR-CONDITIONING IN THE UNITED STATES INTRODUCTION...

The phase out of R22. Phase out of HCFCs

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

Part A: Fluid properties

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume Refrigerant History

It s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

GEOTHERMAL HEAT PUMP SYSTEMS ARE RED HOT BUT ARE THEY REALLY GREEN?

RS-24 (R426A): Q & A

Chapter 3.4: HVAC & Refrigeration System

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Mohan Chandrasekharan #1

Optimization of Water - Cooled Chiller Cooling Tower Combinations

THE F-GAS REGULATION AND ITS IMPLICATIONS IN FIRE SUPPRESSION APPLICATIONS

Industry insight. Refrigerant gases: an industry in transition.

HCFC phase-out has started.

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Refrigerants for Residential and Commercial Air Conditioning Applications

USC CFC Leak Repair and Recordkeeping Procedures

DECISION TIME? A REPAIR OR REPLACEMENT GUIDE FOR HVAC EQUIPMENT

RS-44 (R424A) : Q & A

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

R-32. The next generation refrigerant for air conditioners and heat pumps

Fujitsu General New Zealand Ltd

CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

EU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps

DECISION TIME? A REPAIR OR REPLACEMENT GUIDE FOR HVAC EQUIPMENT REPAIR OR REPLACEMENT GUIDE

How To Know If Cfc 12 Is Still Needed

Federal Clean Air Act Section 609 Training Manual & Exam

REFRIGERANT REFERENCE GUIDE

History of Chlorofluorocarbons

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

THE HIGH COST OF COOL THE ECONOMIC IMPACT OF THE CFC PHASEOUT IN THE UNITED STATES

AHRTI Report No LIFE CYCLE CLIMATE PERFORMANCE MODEL FOR RESIDENTIAL HEAT PUMP SYSTEMS. Final Report. October 2011

Calculating HFC and PFC Emissions from the Manufacturing, Installation, Operation and Disposal of Refrigeration & Airconditioning

Tim Facius Baltimore Aircoil

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Creating Efficient HVAC Systems

Guidance for Stationary Refrigeration & Air- Conditioning

Environmental perspective in intelligent products and processes

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

Environmental Guideline for Ozone Depleting Substances (ODS s) and Halocarbon Alternatives

Refrigerant Compliance Policy

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Low GWP Replacements for R404A in Commercial Refrigeration Applications

SINTEF Energy Research Life Cycle Climate Performance (LCCP) of Mobile Air-Conditioning Systems

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Refrigerant Update and Beyond. Stephen Niles Refrigeration/Commercial Sales Manager

Automobile Air Conditioning Primer

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Elements Elements describe the essential outcomes.

HVAC Systems: Overview

The Importance of Mobile Air Conditioning to Climate Protection. Stephen O. Andersen US EPA

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

High Pressure Ammonia Systems New Opportunities

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

Certification Training Manual

Analysis of Alternative Refrigerants to HCFC-22

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

R-152a Refrigeration System for Mobile Air Conditioning

Guide to good leak testing

Energy and Global Warming Impacts of HFC Refrigerants and Emerging Technologies

Planning for the ban on R22 in building air conditioning

Glossary of Heating, Ventilation and Air Conditioning Terms

AHRI Begins Second Phase of Low-GWP AREP Testing AHRI Completes Four Research Projects in 2014

Heat Recovery In Retail Refrigeration

Refrigeration, Air-conditioning and Heat Pump Sector. The Environmental Protection Agency

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

Guidance for Mobile Air Conditioning (MAC) Sectors. Guidance: F Gas and Ozone Regulations Information Sheet MAC 3: Key Obligations

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Extracts from the FINAL REPORT. Denis CLODIC, Stephanie BARRAULT, Sabine SABA. tonnes. CO2 Eq. Emissions. CFC HCFC HFC Others 1 200

Guidance for Stationary Refrigeration & Air-Conditioning

JFK High School, Environmental Science, Mr. Kent Name : Period: Date: 3. Why is ozone important to us and other organisms?

Production of R-134a

EU F-Gas Regulation Guidance Information Sheet 14: Refrigeration, Air-Conditioning and Heat Pump Contractors

EPA 608 Certification. Study Guide. 1 P a g e

Certification Training Manual

Federal Wage System Job Grading Standard for Air Conditioning Equipment Mechanic, Table of Contents

EXECUTIVE ORDER (Amended) On August 7, 2007, Mayor Ross C. Anderson signed an Executive Order

Background. Page 1. Table 1. Environmental impacts of MVAC refrigerants. Global warming potential

SEE INSTRUCTIONS FOR TAKING TEST AND OTHER INFORMATION ON INSIDE FRONT COVER

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Refrigeration and Air Conditioning with Reduced Environmental Impact D. B. Bivens DuPont Fluoroproducts Follow this and additional works at: http://docs.lib.purdue.edu/iracc Bivens, D. B., "Refrigeration and Air Conditioning with Reduced Environmental Impact" (2000). International Refrigeration and Air Conditioning Conference. Paper 521. http://docs.lib.purdue.edu/iracc/521 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

REFRIGERATION AND AIR CONDITIONING WITH REDUCED ENVIRONMENTAL IMPACT Donald B. Bivens DuPont Fluoroproducts Wilmington, Delaware ABSTRACT Manufacturers of refrigerants and refrigeration and air conditioning equipment, governmental agencies, and environmental groups continue working together toward the goal of reduced environmental impact via reduced emissions and improved energy efficiency. Examples of progress are presented for several sectors of refrigeration and air conditioning, followed by projections for further significant reductions. Working fluid selection for the myriad of refrigeration and air conditioning applications is based on three factors: safety (toxicity and flammability), environmental impact (stratospheric ozone and climate change), and performance (cooling and heating with required capacity, energy efficiency, reliability, and cost effectiveness). Although this paper will emphasize environmental impact for fluid selection, all of the factors must be evaluated to determine the most appropriate fluid for each application. INTRODUCTION Hydrofluorocarbon (HFC) working fluids have been mainly chosen to replace chlorofluorocarbons (CFCs) in refrigeration and air conditioning due to high merits in safety, performance, and no effect on ozone depletion. HFC compounds generally have lower global warming potential values than CFCs, but these values are higher than for fluids such as ammonia, hydrocarbons, and carbon dioxide. To minimize the impact of HFCs on climate change, it is important for industry to continue improving stewardship-inuse practices. This includes selection of HFCs for applications with high societal value, and cradle-tograve management of emissions during HFC production, transportation, use, equipment servicing, and final recovery. Refrigeration and air conditioning equipment is being designed and operated for reduced HFC emissions, and with improved energy efficiency for reduced carbon dioxide emissions. ENERGY EFFICIENCY AND EMISSIONS Unlike the situation with stratospheric ozone depletion in which chlorine containing compounds are being phased out to protect the ozone layer, climate change discussions are appropriately focused on emissions. The Kyoto Protocol is based on a "basket of gases" so no single class of gases must be targeted for phase out. HFC compounds have a range of global warming potential values and are included in the basket. For the high societal value refrigeration and air conditioning applications, 1-IFCs are prime candidates for reducing net emissions within the basket of gases. Very specifically, at equivalent costs of other options, climate change impact from minimal refrigerant emissions can be more than offset by improved energy efficiency (thereby reducing C0 2 emissions), while meeting reliability and safety requirements. As one example, with a typical North American split system heat pump having a 5% annualized refrigerant loss, the refrigerant climate change impact can be offset by a 5% increase in energy efficiency. This well-known approach has been described in many publications (examples being 1,2). The following sections describe a progression of energy efficiency improvements and refrigerant emission reductions, demonstrating industry capability and commitment to produce and operate refrigeration and air conditioning systems with a continuing reduction in environmental impact. ENERGY EFFICIENCY IMPROVEMENTS Refrigeration and air conditioning system energy efficiency has been steadily improved by manufacturers due to several driving forces: environmental group actions to increase awareness of Eighth International Refrigeration Conference at 505 Purdue University, West Lafayette, IN, USA- July 25-28,2000

concerns about climate change, increasing focus on reducing energy costs, governmental regulations, and market opportunities for product differentiation. These forces were important factors before the Montreal Protocol, and now have become even more critical due to global climate change. Several examples of energy efficiency improvements in the United States refrigeration and air conditioning markets follow. It is essential to note that energy efficiency improvements have continued through the time of the transition from CFCs, proving that HFCs provide the same or better energy efficiency than CFCs. Supporting references can be found in several publications (3,4). Domestic Refrigerator-freezer Domestic refrigerator-freezer energy consumption in the United States has decreased from 1750 kwh/year in 1972 to 700 kwh/year in 1993, a decrease of 60% (5) (Figure 1). These values are for a typical size unit of20 fe (570 liter). Governmental standards in 1990 and 1993 assisted in continuance of the downward trends. One manufacturer of refrigerator-freezers introduced a unit in 1995 that meets the projected 2001 energy efficiency standards: a reduction of 30% in energy consumption. The energy consumption for this appliance is equivalent to that of a 60 watt light bulb. Unitary Air Conditioning Similar improvements in energy efficiency have occurred in unitary air conditioning products (6). Figure 2 illustrates the (shipment weighted) energy efficiency ratings of unitary air conditioners in the United States, with improvement from 7 to 10.8 SEER (energy efficiency ratio) from 1975 to 1995. This represents a reduction in energy consumption of 35%. Again, governmental regulations and market competition were major reasons for the improvement. Increased energy efficiency standards of about 20% are expected to be announced in 2001, becoming effective in 2006. Centrifugal Chillers Centrifugal chiller manufacturers have made significant improvements in chiller efficiency as shown in Figure 3 (7). Data for the highest efficiency chillers show a 33% reduction in energy consumption from 1978 to 1998. The highest energy efficiency chillers operate with the low pressure refrigerants CFC-11 and now HCFC-123. The reasons for high energy efficiency are based on refrigerant thermodynamic properties and equipment design features such as the use of multiple stage, direct drive compressors. Further reductions in power consumption from the present 0.48 kw/ton to 0.45 kw/ton are expected by 2005 (8). Auto Air Conditioning There has been minor concern for auto air conditioning energy efficiency over the years, as system run time and fuel to operate the air conditioning systems are relatively low values. Estimates of system operating times are 67 hours/year in Japan to 107 hours/year in North America (9), and gasoline to operate the air conditioning systems is about 3.3% of yearly vehicle gasoline consumption in the United States (10). However, with current research underway on potential use ofhydrocarbons or carbon dioxide in auto air conditioning, attention is being given to total environmental impact of systems operating with HFC-134a refrigerant (refrigerant emissions and energy consumption). A recent publication (10) contains an analysis of options to reduce auto air conditioning environmental impact, concluding that energy efficiency of systems operating with HFC-134a can be realistically increased by 53% under idle conditions and by 38% under down the road conditions. The realistic improvements included increased compressor efficiency, heat exchanger design changes, and lubricant containment in the compressor. Combining these improvements with reduced refrigerant emissions and operation with 50% recirculated air, the climate change impact of the HFC-134a system is somewhat lower than that of carbon dioxide systems. There are other considerations in the debate between auto air conditioning systems based on HFC-134a and carbon dioxide (system reliability, first cost, maintenance costs), but these are beyond the scope of this paper. Eighth International Refrigeration Conference at 506 Purdue University, West Lafayette, IN, USA- July 25-28, 2000

REDUCED REFRIGERANT EMISSIONS Emphasis in this section will be directed to refrigerant emissions from auto air conditioning and supermarket refrigeration systems, as they have had the highest amounts of leakage; however, low emission rates from other systems are briefly described. The projected long term reductions in emission rates for all the applications are based on industry commitment to low emission goals through equipment design, operating and maintenance procedures, refrigerant recovery, and appropriate governmental regulations. Domestic Refrigerator-freezer Domestic refrigerator-freezers are built with hermetic systems having refrigerant emissions mainly in the case of system damage. Calculations of climate change impact are often based on the small refrigerant charge not being recovered at the end of the useful life of the unit. For a typical North American refrigerator, this loss amounts to 2.4% of the total equivalent carbon dioxide emissions (11). This is similar to the 3% value of equivalent carbon dioxide emissions reported in a study of European refrigerators (12). Mandatory government requirements for refrigerant recovery will reduce refrigerant emissions by 75% such that the above loss rates will become 0.6% and 0.75%, respectively. Centrifugal Chillers Centrifugal chiller refrigerant emission rates have been dramatically reduced. Calm (13) reported historical emission rates (1980's) of 8% of total charge annually, with 10% additional loss when equipment was retired. At the time of Calm's report (1993) the emission rates had been reduced to 4% and 5%, respectively. A study (14) of HCFC-123 centrifugal chiller operation revealed annual loss rates of0.46%, which is in agreement with an estimate of0.5% (15) for a well-maintained chiller. With further technology changes the possibility exists for this total loss rate to be reduced to less than 0.1 %, or a five fold improvement (16). It is important to note this is a total loss rate, which includes typical service and maintenance leakage but also accidental losses. Leak rates are dependent on system pressure, so refrigerants with lower boiling points (higher pressures) than HCFC-123 will require more attention to achieve these low emission rates. Unitary Air Conditioning Unitary air conditioning equipment ( ducted residential unit with compressor and heat exchanger remotely located from the evaporator coil) historical emission rates have also been 8% of total charge annually (13), with disposal venting loss of 40%. United States governmental regulations for refrigerant recovery had reduced 1993 estimates to 4% for annual losses and 5-10% for disposal losses. A 1997 report (17) estimated year 2005 annual loss rates reduced to 2%. These reductions are possible through continuing industry efforts improving fitting integrity, service procedures, and systems designed with smaller charge sizes. Auto Air Conditioning Auto air conditioning refrigerant loss rates were estimated to be 35% of charge annually in the 1970's and 80's (18) due to service procedures followed with no awareness of potential environmental impact. This included procedures such as venting refrigerant during system repair, and top-off of leaking systems instead of leak repair. With the Montreal Protocol ratification, the United States Clean Air Act Amendments taking effect November 15, 1991, and follow-on regulations by the United States Environmental Protection Agency, auto air conditioning service organizations were required to recover refrigerant during equipment servicing. This included training and certification of repair personnel, use of approved recovery equipment, and record keeping. It was estimated in 1991 that refrigerant losses would be reduced 67% by improved refrigerant handling procedures (requirements) and better system containment. Eighth International Refrigeration Conference at 507 Purdue University, West Lafayette, IN, USA- July 25-28,2000

Better system containment is being accomplished through attention to many details in systems using HFC-134a. Examples are use of hoses having lower permeation rates, improved fitting designs (gaskets, 0-rings ), and highly sensitive leak detection procedures used in checking components such as heat exchangers during manufacturing. Estimates of auto air conditioning refrigerant emissions depend on the number of refrigerant recharges over the 12 year equipment lifetime, losses during servicing and at end of life recovery (19). Current estimates are a recharge of 40% of the charge at four year intervals, 6% service loss at each recharge, and 25% loss at end oflife. This is calculated to be an annualized loss of 12% of the refrigerant charge. Improvements are expected in refrigerant containment to one recharge of 40% at an eight year interval. With the other above assumptions in losses, this is calculated to be an annualized loss of 7.2% of the refrigerant charge. Future trends toward electric vehicles will permit hermetic air conditioning systems which will be nearly free of emissions. Supermarket Refrigeration- Direct Expansion Supermarket refrigeration systems have a similar history of refrigerant emissions: 30 to 50% loss of charge per year (20) in large systems having display cases located remotely from the compressor/condensing units. In addition to historical practices that did not require refrigerant recovery, a mid-sized supermarket in the United States is estimated to have 18 miles (29 km) of refrigerant piping and 16,000 connections, representing many opportunities for leaks {21). The same regulations described in the section on Auto Air Conditioning were applied to supermarket refrigeration systems. A provision that particularly impacted the supermarket industry was requirement for leak repair of systems with refrigerant charge sizes over 50 pounds. In working to reduce refrigerant losses, supermarket engineers identified and quantified leak sources. One study (21) described a series of leak reduction technologies and procedures that could be used by supermarket facilities personnel. Applying these technology and procedure changes resulted in refrigerant loss reductions of 50 to 80% versus previous operation for these types of supermarkets, which would calculate to be annual loss rates of7 to 17% (if35% previous). These lower loss rates are similar to data from other sources (22) reporting 1996 ranges of 12 to 15%, with lowest possible future rates estimated to be 4 to 8%. Supermarket Refrigeration-Distributed Systems These systems normally have the compressors located near the evaporator in the display case, distributed throughout the supermarket. These systems can use a water loop to connect all the compressors with a remote cooling unit to reject waste heat. Without the long lines from the compressor room to the display cases, refrigerant charge for distributed systems can be reduced by 75 to 80%. The reduction in piping connections and valves also means lower refrigerant losses; 1996 estimate of distributed system refrigerant emissions was 5% per year, eventually dropping to 2% per year (23). Supermarket Refrigeration- Secondary Loop Systems Secondary loop systems (heat transfer fluid circulated through display case cooling coils) should have similar reduction in refrigerant charge, refrigerant piping connections and valves, as distributed systems. Refrigerant emission estimates are 4% per year, dropping to 2% per year (23). Secondary loop systems have had higher installation costs than direct expansion systems, and cost effectiveness analysis should be part of system selection criteria. Summary of Refrigerant Emission Reductions Trends of refrigerant emission reductions (North American equipment) from the 1980's to the present and to the future are presented in Figure 4. Refrigerant emissions are described in terms of percent Eighth International Refrigeration Conference at 508 Purdue University, West Lafayette, IN, USA- July 25-28,2000

of refrigerant charge lost per year. Included are all the types of losses such as system leaks, losses during servicing, and during final refrigerant recovery. CONCLUSIONS 1. Industry, environmental groups, and governmental agencies have cooperated over the last two decades to bring about dramatic reductions in refrigeration and air conditioning systems energy consumption and refrigerant emissions. The reductions have been possible through a combination of factors: increased environmental impact awareness, commitment of industry personnel, improved systems technology and operating/service procedures, and governmental regulations. 2. These successes give us great confidence in continuing efforts for reduction of climate change impact of refrigeration and air conditioning system. 3. HFC refrigerants have high societal value in providing safe and reliable refrigeration and air conditioning. At equivalent costs of other options, climate change impact from minimal refrigerant emissions can be more than offset by improved energy efficiency. REFERENCES 1. March Consulting Group, 1998. Opportunities to Minimise Emissions ofhydrojluorocarbons (HFCs) from the European Union, European Commission DGITI-C-4, United Kingdom. 2. Sand, J.R., Fischer, S.K and Baxter, V.D. 1997. Energy and Global Warming Impacts of HFC Refrigerants and Emerging Technologies. US Dept. of Energy and Alternative Fluorocarbons Environmental Acceptability Study (AFEAS), Washington DC and Oak Ridge, TN, USA. 3. Riemer, A., and Hansen, P.E. 1996. Analysis of R-134a Cabinets from the First Series Production in 1990, Proceedings ofthe 1996 International International Refrigeration Conference at Purdue, West Lafayette, IN, p. 501. 4. Fischer, S.K., Hughes. P.J., Fairchild, P.D., Kusik, C.L., Dieckmann, J.T., McMahon, E.M., and Hobday, N. 1991. Energy and Global Warming Impacts ofcfc Alternative Technologies, Oak Ridge National Laboratory, AFEAS, U.S. DOE, Oak Ridge, TN, p. 8.5. 5. Sand, et.al.. 1997, p. 22. 6. ARI. 1999. Statistical Profile of the Air-Conditioning, Refrigeration, and Heating Industry, 4301 North Fairfax Drive, Arlington, VA, USA, p. 28. 7. American Standard Inc. 1999. Earth Wise Today, Vol. 24, January 1999, La Crosse, WI, p. 3. 8. Smithart, E. 1999. Private Communication from E. Smithart oftrane Company, La Crosse, WI. 9. Fischer, S.K, Tomlinson, J.J., Hughes, P.J. 1994. Energy and Global Warming Impacts of Not-in Kind and Next Generation CFC and HCFC Alternatives, Oak Ridge National Laboratory, AFEAS, U.S. DOE, Oak Ridge, TN, p. 96. 10. Bhatti, M.S. 1999. Enhancement of R-134a Automotive Air Conditioning System, SAE Technical Paper 1999-01-0870, SAE International, Warrendale, PA. 11. Fischer, et.al. 1991, p. 4.11. 12. March Consulting Group, p. 37. 13. Calm, J.M. 1993. Comparative Global Warming Impacts of Electric Vapor Compression and Direct Fired Absorption Equipment, report TR-103297, Electric Power Research Institute, Palo Alto, CA. 14. American Standard Inc. 1999, p. 6. 15. Hourahan, G. 1996. Private Communication from G. Hourahan of the Air Conditioning and Refrigeration Institute to J. R. Sand of Oak Ridge National Laboratory, Oak Ridge, TN, reported in Sand, et.al. 1997 (above reference #2). 16. Smithart, E. 1999. Privatae Communication from E. Smithart oftrane Company, La Crosse, WI. 17. Sand, et.al. 1997, p. 43. 18. Fischer, et.al. 1991, p. 8.1. 19. Baker, J.A. 1997. Mobile Air Conditioning Alternative Systems and the Global Climate, oral presentation at International Conference on Ozone Protection Technologies, Washington, DC. Eighth International Refrigeration Conference at Purdue University, West Lafayette, IN, USA- July 25-28,2000 509

20. Gage, C. 1998. Reducing Refrigerant Emissions from Supermarket Systems, ASHRAE Journal, Atlanta, Georgia, November 1998, p. 32. 21. Troy, E.F. 1997. Options for Reducing Refrigerant Emissions from Supermarket Systems, EPA- 600/R-97-039, Washington, DC. 22. Sand, et.al. 1997, p. 77. 23. Sand, et.al. 1997, p. 78. Dorrestic Refrigerator-Freezer electricity use (kv\ih/year) 2000 -~--------------------. I l_ -1-9-i?O- ~~ c--- ---------------- - --- I o~~--~--~--~--~ I ---19-i75 1_980~Year~1-985~~ ~-990------ --1~ I Figure 1. Domestic Refrigerator-Freezer Electricity Use Data Unit with 570 liter internal volume (United States, Reference 5). Unitary Air Conditioners Energy Efficiency Ratio 11.-----------------------------------~-. a: 10 +-------- w 9t-------------:;;:::.~...--- ~ a: 8 +-------=-'-~--------- w 7 6+---------~--------~--------.---------.-~ 1975 1980 1985 --------------- Year 1990 1995 Figure 2. Unitary Air Conditioner Energy Efficiency Ratio for United States shipments. Data from ARI (Reference 6). Eighth International Refrigeration Conference at Purdue University, West Lafayette, IN, USA- July 25-28, 2000 510

,---------- ----------~-- ----------------- Chiller Energy ConsurJ1ltion 0.9 --.----------------------. 0.8 average I 0.5 I o.4 +-----:-----r-------r------;------l I _ 1975 1980 1985 1990 1995 2000 Year Figure 3. Centrifugal Chiller Energy Consumption Data United States shipments, Reference 7. Annual Emission Rates -+-chiller -auto a/._superm -unitary ---- - 1980's current Time Period future Figure 4. Trends in Refrigerant Emission Reductions Data and estimates from equipment in United States References 13-23. Eighth International Refrigeration Conference at Purdue University, West Lafayette, IN, USA- July 25-28, 2000 511

Eighth International Refrigeration Conference at 512 Purdue University, West Lafayette, IN, USA- July 25-28, 2000