Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the



Similar documents
Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

APPENDIX J GAS DISTRIBUTION

Where life interacts with infrastructure.

Corrosivity of Water Supplies

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING REPORT HOLDER: CURAFLO IP LLC 4035 E. OASIS STREET MESA, AZ 85215

Lead and Copper Corrosion Control in New Construction [Project #4164]

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

HERNDON/MUNCEY, INC. Office: (281) INVESTIGATIVE PLUMBING

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

BELCO PIPE RESTORATION

Open Channel Diffusers

STRONG FLEXIBLE. HyperPure PURE

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

SUMMARY OF DISTRIBUTION INTEGRITY MANAGEMENT PROGRAM

ANSI / ISEA Z Compliance Checklist

Households Preferences for Plumbing Materials

Water System Disinfection

COMMON MYTHS ABOUT FIRE SPRINKLER PROTECTION

Program Design and Engineering Key to Infrastructure Replacement and Cost Containment

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS


LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Shingle Installation Guide

Executive Summary. Introduction

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Engineering Specifications

Technical Losses in Natural Gas Transportation, Distribution, and Storage. Paul Metro Pennsylvania Public Utility Commission

Service Line Warranties of America (SLWA) is the Preferred Service Line Warranty Partner of the City of San Diego

Amendments to the 2012 International Plumbing Code

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

Meeting the Challenge of Pipeline Emergency Repair

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

PROTECT WHAT YOU VALUE MOST

Trade Standard of Town Construction in PRC

S Y S T E M M O D E R N I Z A T I O N

Restoration Services Company

Condition Assessment of a 48 PCCP Water Main Within an Abandon Subway Tunnel

PLBG/GAS SAFETY Information Bulletin

Corrosion Control & Cathodic Protection for Water & Wastewater Systems

LEAK DETECTION IN UNDERGROUND PIPELINES OF MUNICIPAL WATER DISTRIBUTION

Design Criteria & Service Goals

WHAT YOU NEED TO KNOW ABOUT INSURING A HOME WITH FIRE SPRINKLERS

Water Quality Contingency Planning Standard EPB 540B

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Reticulation sewers in basements Technical guidelines

Plumbing Identification and Damage Assessment Guide

The Underground Infrastructure Crisis: Rebuilding Water and Sewer Systems without a Flood of Red Ink

Get Ahead of Rising Alberta Insurance Rates

Force Main Condition Assessment: New Technologies & Case Studies

Presented By: Fred J. Sánchez Water Quality Operations Supervisor

Getting More Out of the Water We Have

Corrosion Inhibition of Dry and Pre-Action Fire Suppression Systems Using Nitrogen Gas

Summary Of The Reduction Of Lead In Drinking Water Act And Frequently Asked Questions

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

UNITED STATES DISTRICT COURT MIDDLE DISTRICT OF FLORIDA TAMPA DIVISION COMPLAINT. COMES NOW, the Plaintiff, JOSEPH DELFRATE, and sues the Defendant,

Water Loss and Leak Detection. Gary Armentrout, Project Associate Environmental Finance Center Wichita State University

SECTION 3 SANITARY SEWER DESIGN

FOLLOWING UP Basic Home Maintenance Tips Maintenance Costs

THE STATE OF THE NATIONAL PIPELINE INFRASTRUCTURE

Canada Pipe Lining Technology.

PLUMBING ROUGH IN INSPECTION

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Social Costs of Accidents in Sweden

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

01 - Plastic Pipe Cements and Primers

To many people, a home s plumbing system is perceived as being extremely

Water Storage Tanks. (Cisterns) Drinking water and your health. Water Hauling. Rainwater Collection. Construction Material

Emergency Replacement of Substandard Water Services Policy Review

BULK WATER HAULING GUIDELINES

Les Produits MURPHCO Ltée

TREE ROOTS & SEWER LINE INTRUSION

WASTEWATER MANAGEMENT SYSTEM

Guaranteed Solutions for Solving Sewer Backups

SANITARY SEWER SPECIFICATIONS

4 Steps for Quality Sewer Performance in Perpetuity

Flood disaster preparedness and resilience

Water Pressure Reducing Valves

COWENS RISK SOLUTIONS WATER DAMAGE PREVENTION

What is water main cleaning & lining

Estimating Stormwater System Annual Maintenance and Repair Costs - A GIS Approach

Personal Insurance Underwriting

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos

While all losses can be devastating, TLC Water and Fire Restoration will work diligently from the initial call to the close of the loss to get the

Report on Urban Household Water Use Pilot Survey in Beijing and Tianjin

Structural Pipe Lining Technology

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER. Dear: Human Resources

C I T Y O F S E L M A F I R E D E P A R T M E N T

Facility Operations Physical Safety Guidance Document

PEX Pipes for Plumbing Applications

Response to Standard Exceedances of Lead in Drinking Water Supplies under O.Reg.170/03

Rehabilitation Scenarios for Sustainable Water Mains. University, Montreal, Quebec, Canada, PH (514) ext. 8779; FAX (514) ;

Transcription:

CHAPTER 1 - INTRODUCTION 1. 1 Motivation Recent outbreaks of pinhole leaks nationally are a significant issue. Figure 1.1 shows the national distribution of pinhole leaks based on the data gathered by the Copper Development Association and Plumber s Survey conducted by Dr. Edwards (2004). In the major water distribution system managed by municipalities and water utilities the costs are distributed among all subscribers. However, home plumbing repair/replacement cost and possible water damage cost must be addressed by the homeowner. When a pipe has a corrosion hole, the homeowner is typically faced with the following issues: water damage cost, repair cost, service disruption, lowering of home value, home insurance premium increase, and health consequences such as resulting from brown mold growth and mental stress from both concentrated nature of individual repair damage costs and health effects. Home owners near the hot spot areas are considering additional treatment to water in terms of corrosion inhibition, different plumbing materials such as plastics and stainless steel, and coating the interior of the pipe. Homeowners are also seeking advice on whether to continue to repair or replace the plumbing system. A repairable asset is considered to be in continued use but can be restored to a new state, better, about the same, or worse for a cost at the time of repair. Assume W 0 be the initial value of the home plumbing system and W 1 is its value after a corrosion incident with a repair/ replacement cost of R. The loss is therefore due to repair and the value lost [R+ (W 0 -W 1 )]. Now, the same construct is repeated for N repairs accounting for proper discounting. At the N th repair a decision has to be made whether to replace the system with an alternative or continue to repair it. This decision is obtained by minimizing the total discounted loss over N times. At each repair, the available alternatives are examined in place of retaining the old pipe. (Loganathan, MUSES proposal, 2002) 1

Also a decision on using other pipe material such as plastic, stainless steel, and copper with increased wall thickness has to be made. These different materials have to be considered for cost, consumer preference from the point of view of selling the house, corrosion susceptibility, strength, behavior in the case of a fire, and health effects. Different materials show different leak behaviors. These considerations are shown in Figure 1.2. Figure 1.1 National distribution of pinhole leaks Figure 1.2 Decision making process 2

1. 2 Major System and Minor System considerations Water distribution system is composed of a major system and a minor system. The major system brings treated water to the street level of homes and the minor system carries the water from street level mains into homes (Figure 1.3). Table 1.1 lists the major differences between the major and the minor systems. Figure 1.3 Major and Minor distribution system 3

Table 1.1 Characteristics of Major and Minor distribution system (Loganathan, 2002 MUSES proposal) Characteristic Major System Minor System Pipe diameter 4in 14 in ½ in 1 in Pipe material Ductile iron, Plastic, Cast iron Copper, Plastic, Galvanized iron Pipe length In miles (10s to several 100s) In feet (several 100s) Pipe wall Copper: K 1.25 1.7 mm; L 1.02 1.3 Ductile iron 6.6 mm and above thickness mm; M 0.71 0.89 mm Corrosion Both internal and external Internal Velocity 3 to 6 ft/sec ~ 4 ft/sec Life expectancy Ductile iron ~ 80 years Copper ~ 80 years; Galvanized iron 40 50 years Ownership Utility End user (Homeowner, companies, industries) Regulation Government Cost Distributed by water rate Individual/insurance; Replace piping $4,000 - $6,000 Property damage Distributed few 100s to several 1000s in dollars Few 100s to few 1000s in dollars Service response Immediate Delayed Customer Dissatisfaction Marginal to serious Serious Availability of the data Records kept computerized May not have records In decision making process, consumers are influenced by various factors. First, the regulations and standards of the federal, state, and local governments have major impacts. These regulations influence plumbers, material producers, insurance companies, and water utility companies; consequently, consumers are influenced by all of the above service providers. Figure 1.4 shows these overall relationships. 4

-Federal Regulations -State Regulations -Local Regulations Plumbers and Insurance companies Water Material (CLUE Report, difficult utility Producers to be covered ) companies Households/ Consumers Figure 1.4 Relations on Consumer decisions Insurance companies have access to CLUE reports (Comprehensive Loss Underwriting Report) which form a comprehensive database of personal property information relating to insurance claims on private property. It is managed by ChoicePoint Asset Co. located in Alepharetta, GA. It contains personal information on the insured, the name of the insurance company involved, the policy number, the claim number, the accident, as well as the amount paid out to the customer. Finally, it lists the customer s claim history report. If a customer calls the insurance company just for an inquiry of home plumbing issues, their call history is recorded on the CLUE report. Therefore, customers may have difficulty in purchasing home insurance (www.franscona.com/resource/jag403clue.htm). The cost of corrosion to public infrastructure is estimated to be in billions of dollars without including loss of about 15% of treated water through leaks. Estimates are that in the USA alone 10~32% of the drinking water is lost due to corrosion at a cost of $22 billion per year. The cost related to corrosion in private drinking water infrastructure, or plumbing in residential, commercial, and school buildings, is nearly twice that of the public infrastructure 5

(Edwards, 2003). A survey in 1999 revealed that copper was selected in 90% of new homes, followed by PEX at 7%, and PVC at 4%. The length of private plumbing in homes, residential facilities, schools, and commercial buildings is 10 times longer than that of the public infrastructure. Copper pipes can result in copper concentration change in drinking water significantly. World Health Organization recommends copper concentration not to exceed 2.0mg/L and USEPA established an action level of 1.3 mg/l for drinking water (Dietrich, 2003). Regarding alternative drinking water sources, developing a well introduces its own water quality related issues and costs. Bottled water is typically expensive and does not address the issue of home use of water for bathing, cleaning, and other domestic activities. The quality of the bottled water has been brought into question regarding the source of that water and the shelf life from processing to consumption. Dual systems supplying potable and non-potable water require the maintenance of two networks and are clearly expensive. Point of use treatment alternatives require separate installation and maintenance costs. Pipe layout can influence the flow patterns that may have impact on corrosion. These alternatives have different life times, impacts and risks (Loganathan, 2002 MUSES proposal). The public s perception of risk and reaction to hazards while hard to measure, play a fundamental role in this problem. Risk is an estimator of uncertainty defined as the probability of failure, which potentially affects consumer s well-being. Objective risks are based on relative frequencies of occurrence obtained from historical or experimental studies. Perceived or subjective risk involves personal or subjective judgment and is a function of confidence. Information should be provided on the implications of risks for consumers as individuals rather than as a group. Incorporation of consumers preferences for water quality improvements in modeling can be performed by contingent valuation, conjoint analysis and decision analysis. Consumer risk averseness and proneness play a dominant role in developing a preference or utility function (Loganathan, Dietrich, 2002 MUSES proposal). 6

1.3 Objectives The objectives of this thesis are to: 1) Develop a detailed description of life cycle assessment procedure and its application to copper plumbing pipe 2) Provide a comprehensive synthesis of aqueous corrosion in plumbing pipes. 3) Develop a decision support tool for repair/replacement of plumbing systems The plumbing system deterioration has emerged as a critical issue for a significant number of home owners throughout the country. The home owners are looking for sound advice on plumbing system repair and replacement. The repair issue involves installing a new pipe along with an older pipe without aggravating the problem. For example, it has been pointed out, copper pipes should never be installed upstream of galvanized iron pipes as it can cause corrosion in galvanized iron pipes. Therefore in hot water recirculation systems, copper galvanized iron combination should be avoided. Protective interior coating of copper pipes and use of plastic pipes are being considered to prolong the life of a plumbing system. In this thesis, the focus is towards the replacement issue rather than the alternative methods of repairing. 1.4 Organization of the thesis In chapter 2, a detailed description of life cycle assessment procedure is given along with details pertaining to copper pipe manufacturing. In chapter 3, a comprehensive synthesis of aqueous corrosion theory is given. Chapter 4 contains a preliminary analysis of observed plumbing pipe leak data. It is found that locations close to water treatment plant suffer the greatest number of leak incidents. It is conjectured that high pressure and relatively high concentration of chlorine might be the causal factors. The leak rates are also calculated 7

corresponding to the various periods in which the houses were built. These leak rates display a late stage behavior and serve as the basis for model development in chapter 5. A decision support tool for finding optimal replacement time for plumbing systems is developed in chapter 5. In this chapter an optimization model that minimizes absolute deviations between theoretical and observed leak rates is given. Also a neural network model for leak rates is developed. These leak rates display age dependence. A non-homogeneous poisson process that accounts for time dependent leak rate is developed to generate leak arrival times. These leak arrival times in turn are used within an economically sustainable replacement scheme for determining the optimal replacement time. Chapter 6 summarizes key contributions of this thesis. 8