VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES



Similar documents
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY

VU53S; VU54S; VU443A; VU444A; VU843A; VU844A Fan Coil Valves and Actuators

Oil and Coolant Circulating Heating System. Model - OCSM

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Operators manual Basic water heater

Assisted lift operated 2/2-way solenoid valves Type EV250B

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

T7079A,B Solid State Remote Temperature Controllers

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Butterfly Valves PN 6/10/16 for flanged connection

Cooling system components, removing and installing

T7560A,B,C Digital Wall Module

Automatic control equipment for HVAC systems

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

stainless steel pre-assembled manifolds

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Cooling system components, removing and installing

HERZ-Thermal Actuators

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Why and How we Use Capacity Control

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

3/2-way Solenoid Valve, direct-acting, NC or NO

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

STC 3S A Series Solenoid Valves

Stainless Steel Single and Dual Circulation Kits

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

AMX300 DirectConnect Mixing Valve Kits

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

TMS TANK MANAGEMENT SYSTEM

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

PRESSURE REDUCING CONTROL VALVE

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Select Radiators Installation Guide

PNEUMATIC CONTROLS Selection and Description

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Data sheet ECC 12 and 22

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

E2 Series Electric Furnaces

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

2- and 3-port valves with flanged connections, PN 10

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Installation, Maintenance, & Repair Series 4000B/LF4000B

G670 Intermittent Pilot Ignition Controls

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

PBX Series Quick Fit Connector Bimetallic Steam Traps

Solid-State Timer H3G

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Isotemp Basic, Slim/B & Slim Square

WD-AMX Water Detection Controllers

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Proportional pressure regulators VPPE

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Aquamax Australia Pty Ltd ABN

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

CEILING CASSETTE FAN COIL UNIT

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Single sub-base valve

3 Port Solenoid Valve

Laddomat Charging unit

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Unit 24: Applications of Pneumatics and Hydraulics

STABITHERM INSTALLATION & SERVICE BOOKLET

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Cooling system components, removing and installing

PLBG/GAS SAFETY Information Bulletin

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Air Conditioning Sign-Off Sheet

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

V94 BULK TAPE DEGAUSSER

Transcription:

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge assembly Actuator with cable or Molex socket Pipe fittings (most versions) Materials 2-way VC valve body VC actuator 3-way VC valve body Valve housing made of bronze Spindle made of stainless steel Cartridge made of Ryton (polyphenylene sulphide) and Noryl (polyphenylene oxide) O-ring seals made of EPDM rubber Actuator cover made of Noryl (94V-0) Actuator base made of Ryton (94V-0) Application Honeywell VC Series balanced 2-position hydronic valves are used in domestic and small commercial heating and cooling applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly 2-way valves are designed for on-off zone control of domestic systems. 3-way valves can be piped for either diverting or mixing valve applications in domestic central heating and/or cooling systems. Both versions can be used to control individual fan coil, radiator, space heater or convector applications. Depending on the model selected they can be controlled by a low or line voltage SPST or SPDT controller such as a room thermostat, aquastat or flow switch. VC Series hydronic valves are designed to take advantage of sinusoidal valve actuator travel, and therefore operate silently and reduce water hammer. Through internal logic the actuator only takes power while driving the valve to the commanded position. The actuator head is removable without affecting the integrity of the water system. All actuator versions are interchangeable with any valve body, offering the highest flexibility for boiler production line assembly, and maintenance. The valve piston construction allows for port sealing that is independent of the differential pressure across the valve. Flow through the 2-way valve can be in either direction, so the ports are not designated. 3-way valves are suitable for both diverting water from AB to A or B, and from A or B to AB. Features Rugged design Control by a low or line voltage SPST or SPDT controller Minimal actuator power consumption Pressure differential up to 4 bar Double insulated actuator Quick connect electrical connections Quick and easy replacement of moving parts Actuator head installation does not require draining of the system High flow rate capacity Honeywell All rights reserved

Specifications Medium Water or water-glycol mixture (max. 50% glycol content), quality to VDI 2035 ph-value 8...9.5 Operating temperature Ambient temperature Operating pressure Differential pressure kvs (cv)-values Flow 1...95 C (34...203 F) 120 C (248 F) short duration peak max. 65 C (149 F) max. 20 bar (290 psi) static max. 100 bar (1,450 psi) burst max. 4 bar (58 psi) see chapter Dimensions below 2-way: flow can be in either direction. When actuator is not mounted valve is in closed position 3-way: bottom port is marked AB. End ports are marked A and B. When actuator is not mounted port A is closed. Voltage Power consumption Auxiliary switch rating Nominal timing Electrical termination Shipping temperature Humidity rating Atmosphere 24 V, 50-60 Hz (blue label) 200-240 V, 50-60 Hz (red label) 4 VA (when valve position changes) 1.0 A @ 250 V, 50-60 Hz (minimum 0.05 A @ 24 Vdc) Valve opens in 7 seconds (20% faster for 60 Hz) 1. Molex socket: requires mating connector, alternatively 2. With integral 1 m leadwire -40 65 C (-40 149 F) 5 95% RH (non-condensing) non-corrosive, non-explosive Function VC Series 2-position hydronic valves are used in domestic and small commercial applications to control the flow of hot and/or cold water. They consist of an actuator, valve and a cartridge assembly.all moving and sealing parts of the valve are constructed in the cartridge assembly. The ports are sealed with O-rings on the outer surface of the piston. When the valve stem is driven down to open port A the water will flow through the hollow piston to the other port. In case of a 3-way valve with the piston driven down port B is sealed, allowing flow between port AB and port A. With the stem up the flow is between port AB and port B. The valve family offers a variety of versions of pipe connections to suit the different applications. The valve pressure loss characteristic is dependent on the pipe connections/ dimensions. For the actual valve rating please refer to the specification section. 2-way valve With an SPDT (3-wire) actuator On a call for heat, the NO controller contacts close and the valve opens. When the valve is fully open, the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied the NC controller contacts close, energising the valve through SW1 and closing the valve. When the valve is fully closed, the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. With an SPST (2-wire and common) actuator On a call for heat, the controller contacts close, RLY1 is e- nergized making the NO contacts in switch SW3 causing the valve to open. When the valve reaches the fully open position the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied, the controller contacts open, RLY1 is de-energized and the valve motor is driven through SW1 and the NC contacts of SW3. When the valve reaches the fully closed position, the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. For both types of actuator a power failure will leave the valve at the position it was when interrupted. When power is restored, the valve will respond to controller demand. Fig. 1. Fluid flow through 2-way VC valve 2 Honeywell All rights reserved

3-way diverter valve With an SPDT (3-wire) actuator On a call for heat, the NO controller contacts close, the valve closes port B and opens port A. When port A is in the fully open position the cam closes limit switch SW1 and opens limit switch SW2. When the need for heat is satisfied the NC controller contacts close, energising the valve through SW1, causing port A to close. When port A is fully closed the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. With an SPST (2-wire and common) actuator On a call for heat the controller contacts close, RLY1 is energized making the NO contacts in switch SW3, causing port B to close and port A to open. When port A reaches the fully open position the cam closes switch SW1 and opens switch SW2. When the need for heat is satisfied, the controller contacts open. RLY1 is de-energized making the NC contacts in SW3 and port A is driven closed through SW1 and the NC contacts of SW3. When port A is in the fully closed position the cam closes SW2 and opens SW1. The valve is ready for the next call for heat. For both types of actuator a power failure will leave the valve at the position it was in when interrupted. When power is restored, the valve will respond to controller demand. Fig. 2. Fluid flow through 3-way VC valve Wiring Figures 3 and 4 show wiring connections for 2-way and 3-way valves. Port A open and closed denotes valve open and closed for 2-way, and AB-A open and AB-B open for 3-way valves respectively. A means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring. On Molex connector models, actuator and auxiliary switch voltages must be the same to meet the approval requirement. For mixed voltages, the cable assembly version is recommended. Fig. 3. Logic sequence diagram with 3-wire actuator for SPDT contoller Fig. 4. Logic sequence diagram with 2-wire + common actuator for SPST contoller Honeywell All rights reserved

Dimensions Fig. 5. 2-way VC valve Fig. 6. 3-way VC valve Table 1. Dimensions and kvs-value Body 2-way VC valve 3-way VC valve C kvs-value C D kvs-value 15mm compression 98 3.4 98 136 4.3 22mm compression* 112 6.8 112 140 8.6 28mm compression* 112 7.7 112 140 8.6 1/2 BSPP (external) 98 3.4 98 136 4.3 3/4 BSPP 94 6.8 94 130 7.7 1 BSPP 94 7.7 94 136 8.6 1/2 sweat 98 3.4 98 136 4.3 3/4 sweat 94 6.8 94 132 8.6 1 sweat 94 8.6 94 136 8.6 NOTE: All dimensions in mm * Includes compression nuts and olives Ordering Information Use the Valve Selection Chart to find the right version. The Valve Selection Chart provides the necessary information to put together the OS-No. (OS=Ordering System). Example with OS-No. VC6012MP6000E: VC6012MP6000E Product family. Always VC Accessories and packing specifier see Valve Selection Chart column E Actuator specifier see Valve Selection Chart column A Body specifier see Valve Selection Chart column B Customisation specifier see Valve Selection Chart column D Cartridge specifier see Valve Selection Chart column C 4 Honeywell All rights reserved

Valve Selection Chart Honeywell All rights reserved

Installation WARNING Installer must be a trained, experienced service person. When installing this product: Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure it is suitable for your application. Always conduct a thorough checkout after installation. CAUTION Disconnect power supply before wire connection to prevent electrical shock and equipment damage. It is advisable to remove the actuator head from the valve body for ease of installation. Fit the actuator head in the most convenient position for wiring. On sweat fitted valves, the cartridge is shipped loose or is removed to avoid being damaged during the solder operation. On 24 V systems, never short circuit the valve coil terminals. This may burn out the heat anticipator in the thermostat. To remove the actuator head 25 mm clearance is needed above the actuator. Plumbing The valve may be plumbed in any angle but preferably not with the actuator head below the horizontal level of the valve body. Make sure there is enough room around the actuator head for servicing or replacement. When used to form part of a central heating system, do not locate it where it will block the system vent, cold feed or any bypass when the valve is closed. Mount the valve directly in the tube or pipe. Do not grip actuator head while making and tightening plumbing connections. Either hold valve body in your hand or attach adjustable spanner across the hexagonal or flat faces on the valve body. Compression models For compression fitted models, tighten the compression nuts enough to make a watertight seal. Take care not to overtighten. Fig. 7. Plumbing To install a replacement actuator head Fig. 8. Latch mechanism Important Installation of a new actuator head does not require draining the system providing the valve body and cartridge assembly remain in the pipeline. 1. Disconnect power supply before servicing to avoid electrical shock or equipment damage. 2. Disconnect leadwires to actuator head, or depress tab on Molex connector and remove. Where appropriate, label wires for rewiring. 3. The actuator head is automatically latched to valve (see figure 8). To remove, lift up on the latch mechanism located directly below the red manual open lever. Press the actuator head down towards the body with moderate hand force and turn counter-clockwise by 1/8 turn (45 degrees) simultaneously. Lift the actuator head off the valve body. NOTE: Actuator can also be installed at right angles to valve body but in this position latch mechanism is not engaged. 4. Install the new actuator head by reversing process in (3). 5. Reconnect leadwires or Molex connector. 6. Restore power. 6 Honeywell All rights reserved

Adjustment and Testing Manual Opener The manual opener can be manipulated when in the up position. The motorized valve can be opened by firmly pushing the red manual lever down to midway and in (only possible if the actuator is in the upper position). This holds all ports in the open position, and with auxiliary switch models the NO switch is closed. Ports A and B of 3-way valves are opened. This 'manual open' position may be used for filling, venting or draining the system, or for opening the valve in case of power failure. The valve can be restored manually to the closed position by depressing the red manual lever lightly and then pulling it out. The valve actuator returns to the automatic position when power is restored. Checkout 1. Raise the set point of the thermostat above room temperature to initiate a call for heat. Valve position indicator should move downward to the open position. 2. For all auxiliary switch models, monitor the control devices. 2-way valve: check that the valve opens, the auxiliary switch (if present) closes, and at the end of the opening stroke the circuit to the circulator or another valve is made. 3-way valve: check that port A opens, port B closes, the auxiliary switch (if present) operates, and at the end of the opening stroke the circuit to the circulator or another valve is made. 3. Lower the set point of the thermostat below room temperature. 4. Observe the control devices. 2-way valve: check that the valve closes and all auxiliary equipment stops. 3-way valve: check that port A closes and all auxiliary equipment stops. Service WARNING This valve should be serviced by a trained, experienced service person. 1. If the valve is leaking, drain system or isolate valve from the system. 2. Check to see if the cartridge needs to be replaced. 3. If the gear train or the motor is damaged, replace the actuator assembly. NOTE: Honeywell hydronic valves are designed and tested for silent operation in properly designed and installed systems. However, water noises may occur as a result of excessive water velocity. Piping noises may occur in high temperature (over 100 C) systems with insufficient water pressure. Honeywell All rights reserved

Flow Diagrams Fig. 9. Valve pressure loss characteristic Port flow (%) Travel (%) Fig. 10. Typical 3-way valve diverting characteristic at constant pressure on port AB ACS Control Products Honeywell GmbH Möhnestraße 55 59755 Arnsberg, Germany Phone: +49 (2932) 9880 Fax: +49 (2932) 988324 www.honeywell.com February 2006 2005 Honeywell International Inc. Subject to change All rights reserved Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland or by its Authorized Representative.