Monitoring of Power Transmission through Cables



Similar documents
ARTIFICIAL NEURAL NETWORK FOR OVERHEAD TRANSMISSION LINE MONITORING

Study on Differential Protection of Transmission Line Using Wireless Communication

International Journal of Computer Engineering Science (IJCES)

Network Enabled Battery Health Monitoring System

Wireless power meter monitoring with power theft detection and intimation system using GSM and Zigbee networks

Wireless Sensor Network Based Low Power Embedded System Design For Automated Irrigation System Using MSP430

Intelligent Home Automation and Security System

Design of Wireless Home automation and security system using PIC Microcontroller

DEVELOPMENT OF VIBRATION REMOTE MONITORING SYSTEM BASED ON WIRELESS SENSOR NETWORK

Design of WSN-Based Remote Monitoring System for Environmental Parameters in Substation

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

FaultAnalysisandElectricalProtectionofDistributionTransformers

Online Communication of Critical Parameters in Powerplant Using ZIGBEE

Design of Fuzzy Drip Irrigation Control System Based on ZigBee Wireless Sensor Network

SCADA and Monitoring for Solar Energy Plant

A Study of Low Cost Meteorological Monitoring System Based on Wireless Sensor Networks

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Respecting the environment

Using NTC Temperature Sensors Integrated into Power Modules

Plc Based Monitoring and Controlling System Using Wi-Fi Device

Open Access The Wireless Environment Monitoring Alarm System Based on Selforganizing

Design and Implementation of Remote/Short-range Smart Home Monitoring System Based on ZigBee and STM32

Electrical Resistance Resistance (R)

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2

emobility WAGO Leading the Charge

DEVELOPMENT OF INDIVIDUAL HOME SECURITY SYSTEM USING CAN AND ZIGBEE PROTOCOL

Wireless Sensor Network for Electric Meter Handling

Monitoring and Controlling Power using Zigbee Communications

Distributed Temperature Sensing - DTS

ABB. Gene Zhang, PPMV Service/Power World 2014, Smart Switchgear & Cloud Service Remote, but close

ends of transmission line are used for relay operation [70]. Another type of

EFFECTS OF CORONA RING DESIGN ON ELECTRIC FIELD INTENSITY AND POTENTIAL DISTRIBUTION ALONG AN INSULATOR STRING

Design of UPS Battery Remote Monitoring System

DESIGN FOR MONITORING AND OPTIMIZATION OF POWER DEMAND FOR WIRELESSLY COMMUNICATING ELECTRIC LOADS

Stellaris Based Integrating Web Servers in Embedded Applications

Terminal and Dimension

Automobile Speed Violation Detection System using RFID and GSM Technologies

VEHICLE TRACKING SYSTEM USING GPS. 1 Student, ME (IT) Pursuing, SCOE, Vadgaon, Pune. 2 Asst. Professor, SCOE, Vadgaon, Pune

Table of Contents. TransformerIQ FAQs 1

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Water Quality Monitoring System Using Zigbee Based Wireless Sensor Network

Fault location on power cables. Fault location on power cables

A Wireless Sensor Network for Weather and Disaster Alarm Systems

Bus Data Acquisition and Remote Monitoring System Using Gsm & Can

Insulation Resistance Testing of Low Voltage Cables in the Field

Documentation. M-Bus 130-mbx

Application of Wireless Sensor Network and GSM Technology: A Remote Home Security System

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

Tamura Closed Loop Hall Effect Current Sensors

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

Vehicle Scrutinizing using GPS & GSM Technologies Implemented with Ardunio controller

How To Track A Vehicle With A Smart Vehicle Tracking System

Open Access Smart Home System Based on ZigBee Network and STM32F407 Microprocessor. Yongliang Zhang 1,* and Ling Li 2. China

White Paper. Fiber Optics in Solar Energy Applications. By Alek Indra. Introduction. Solar Power Generation

ADM1TE 5/30A DIN rail single phase two wire energy meter

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

ZIGBEE BASED MINE SAFETY MONITORING SYSTEM WITH GSM

Use your troubleshooting superpowers for good Application Note

Chip Diode Application Note

AUTOMATIC ACCIDENT DETECTION AND AMBULANCE RESCUE WITH INTELLIGENT TRAFFIC LIGHT SYSTEM

Market Growth and New Regulations Demand Network Modernization

A Review of Security System for Smart Home Applications

DESIGN OF SMART HOME SECURITY SURVEILLANCE SYSTEM USING GSM

Troubleshooting accelerometer installations

Delta Transportation Automation Solution.

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Quick Connect. quick - simple - efficient.

Unit 4: Electricity (Part 2)

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

Part 1 System Modeling & Studies for Existing Systems

Founded in 1988, Beijing Creative Distribution Automation Co., Ltd (CREAT) is a share holding hightech enterprise based on China Electric Power

Design and Development of a Remote Monitoring and Maintenance of Solar Plant Supervisory System

N4385A / N4386A Distributed Temperature System (DTS)

Design of Self-service Car Washing Machine Control System Based on ARM Zhengmin Cui a, Peng Sun b

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

The design and implementation of the environment monitoring system of smart home based on EnOcean technology

Real Time Water Quality Monitoring System

Remote Monitoring and Controlling System Based on ZigBee Networks

Original Research Articles

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Coal Mine Security System

Terminal and Dimension

Gsm Based Controlled Switching Circuit Between Supply Mains and Captive Power Plant

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

GroundRod AC Substation Earthing Tutorial

AMSC s Superconductor Cable Technologies for Electric Utilities

environment briefing02

DEVELOPMENT OF A WEB-BASED WIRELESS TELEMONITORING SYSTEM FOR AGRO- ENVIRONMENT

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Design of Remote Security System Using Embedded Linux Based Video Streaming

Internet of Things for Smart Crime Detection

Unified requirements for systems with voltages above 1 kv up to 15 kv

ADACSNET USB Control Module

Appendix A - Cost Estimate Spreadsheet

3G Wireless-N Smart Energy Gateway

Cable Size Selection for Energy Efficiency

Wireless monitoring system for temperature and humidity based on ZigBee

Transcription:

Monitoring of Power Transmission through Cables Sahad A M.Tech Student, TKM College of Engineering, Kollam, Kerala, India Abstract: Power transmission overhead line online monitoring [8] was implemented in some countries. This paper mostly discussed about the monitoring of power transmission cables. In densely populated cities overhead transmission has a limit. More over faults are more in overhead transmission due to damage in conductors, birds, temperature, wind and so on. These drawbacks can be avoided to a large extend through underground cables. If it is monitored real time its power transmission capability and reliability can also be increased. Even though this is a costliest type of transmission cables, are adopted in cities. In addition to the underground cables, power cables are used in industry to carry the power from control station to the site. Cable trenches and cable trays are used for this. Key words: Power Transmission, Insulation Resistance, Lightning Arrester, Infrared Sensor, Cable trench, Cable tray. I. INTRODUCTION Power transmission is tedious task.generating stations are far located from cities. The generating voltage in India (standard 11kV) cannot be transmitted as it is. It has to be stepped up for long distance transmission. The factor which is considered are voltage and distance during transmission. Current is a factor since by Joules law (I) H= RT.. (I) Where H is the heat produced, I is the current through the conductor, Resistance of the conductor and T is the time taken through which power is transmitted. By analyzing the law (I) heat loss is directly proportional to the square of the current. So current cannot be increased. By the equation (II) power to be transmitted can be increased by increasing the voltage. P=3VI (for three phase).(ii) Where P is the power, V is the voltage, I is the current and is the power factor of the alternating current system. This power can be increased with more reliability through power transmission cables.3 core and 3 and half core are more common. Racoon is also one type of cable used in India. Its different parameters can be measured using the techniques discussed below. The measured parameters (using Power Transducers) can be transmitted using GPRS techniques. These are interfaced to a Personal Computer for Monitoring. Copyright to IJAREEIE www.ijareeie.com 270

DATA LOGGER Figure I. Monitoring parameters of power cables. Section I(This section) gives the introduction of power transmission. Section II describes about the different parameters to be considered during power transmission through cables. Section III mainly points about the way for transmission of the sensed parameters. Sections IV finally concludes the overview of the paper. II. PARAMETER MEASUREMENTS The different parameters can be measured using sensor technology. Figure I show the block diagram of monitoring parameters of power cable. A.Current Measurements. Current is an important parameter. Each cable is designed for a specific current. This current will raise beyond a limit when fault occurs. The high current produces heat in cable and sometimes damages the insulation. Insulation Resistance measurement is discussed in the coming section.abb High current sensors can be used to measure the current. These types of sensors can measure from 10A to around 1000A (CS 500, CS 1000). The characteristics of ABB sensors are - A model of reliability. - A perfect efficiency in every environment. - Excellent measuring accuracy. - High reliability. - High overload capacity. - Small size: 124 (L) x 100 (W) x 44 or 81 (H) mm. B.Temperature Measurement. [4] Temperature is a parameter which limits the transmission capacity of cables. So temperature has to be measured. In hot countries underground cable and cable in the tray get affected by temperature. Different cable have different temperature withstanding capacity based on insulation(xlpe,epr etc).if the temperature exceeds the limit prescribed the FT series infrared sensor will detect it and send via GPRS. When the temperature is sensed by the sensor it produce an electrical signal. C.Insulator Fault Monitoring. At load centers the cable has to be terminated and are stepped up or stepped down according to the customer needs. The insulator has infinite resistance. But during flash over insulation break down [8].This cannot be identified unless and under system fails. The Copyright to IJAREEIE www.ijareeie.com 271

breakdown occurred in its internal. The insulator flashover discharge between iron cap and iron pin ceramic, the trace cannot be seen, but the insulation has been lost, and it may be completely destroyed due to arcing. For breakdown, the discharge traces of iron legs and burnt situation should be paid great attention. Transmission line insulator flashover [2] in operation can cause blackout accidents, to affect seriously the power grid stability and reliability. All insulators are affected to some extent by impact, thermal and mechanical cycling, ablation from weathering and electro-thermal causes, flexure and torsion. ETCR 085K sensors can be used here. The increase temperature causes the insulation to break down. This produce leakage current which is sensed using sensor module The insulation resistance can be formulated as follows. The cable has a sheath of inside radius R. = ln ohms.. (III) Where is the insulation resistance of the cable, resistivity of the insulating material of the cable, l length of cable and r radius of the conductor. Average value of or impregnated paper varies from 5 X to 8 X ohm meters at 15 This sensor embedded in sensor module transmits the data through GPRS network. D.Lightning Arrester Monitoring Transformer is important equipment in power transmission system. It is also the costliest ac machines. It is very sensitive to lightning. So it has to be protected. Also the cables exposed in Cable trenches in various industries are subjected to lightning. In country like China and Bangladesh it is severe. Thyrite lightning arresters are mostly used in India. The lightning arresters act as insulators for normal current but act as conducting material during surges. When severe lightning occurs it breakdown and does not work effectively. During this time it conducts for normal current also. The current sensor(etcr 080) implemented can also measure this value. The measured values are send to the servers through GPRS technology [5]. E.Power Cable Visual Monitoring Substation and Control station are located away from the site equipments. When insulation failed the conductor may get in touch with cable trench/tray. This will cause damage to the whole system and system gets tripped. The spliced cables also cause problems if not connected properly. So high sensitive CCD camera (SAA71, FPGA Series) are installed. The digital signal is digitized and sends through GPRS technology to the control station. III.PARAMETER TRANSMISSION Smart system for the meteorological monitoring of transmission line based on ZigBee and General Packet Radio Service (GPRS)[6][7] technology was developed in order to overcome the shortcomings of the present system, such as the totally dependence on the limited coverage of communication network, the single monitoring parameters and the poor extensibility, etc. SHT10 integrates the sensing element and signal processing circuit in a micro-circuit board. It has output of standardized digital signal, small size and low power consumption. The system in this paper has the advantages of low power consumption, low node cost, large network capacity, long cycle life and strong extensibility. Figure II shows the block diagram of sensor module. RS-232 are interfaced with the GPRS Module and use wireless communication Technology [3]. The standard provides the Physical layer (PHY) and Network Layer (NWK) for the wireless communication.rs-232 layer has seven layers as OSI Reference Model. Zigbee working on the topper performs as the Network layer (NWK) and Application layer (APL). The PHY, MAC and NWK Copyright to IJAREEIE www.ijareeie.com 272

layers handle the data transmission and the APL layer handles the tasks of each device. CC2430 made by TI (Texas Instruments) was used as MCU and RF module. The chip is chosen to implement the chip system on embedded ZigBee applications. GPRS is a GSM-based wireless packet technology. It provides wide-area wireless IP connection by a kind of point to point way. GPRS is a high-speed data-processing technology, for which data are transmitted in the form of "group"[3]. It has the following characteristics: first, it will remain online as long as GPRS is applied; second, GPRS only charges when it generates communication flow; third, the current GPRS can support the peak rate of 53.6Kbps while theoretical transferring peak reaches more than 100 Kbps.Figure III gives the block diagram representation of GPRS Module. Data Logger[9] is a microcontroller unit (LP 3500) embedded with cell modem and power module. Figure II. Sensor Module Block Diagram Figure III.GPRS Module Block Diagram. IV.CONCLUSIONS Power transmission is through cables in cities and industries. The sensor technology incorporated with the data logger and GPRS technology provide high reliability of the system. The data received from the module are processed and instant remedial measures can be taken. The most vulnerable fault is the breakdown of insulation resistance. The early detection cause the system more attractive to electricity boards and industry. Copyright to IJAREEIE www.ijareeie.com 273

ACKNOWLEDGEMENTS ISSN: 2278-8875 I am highly indebted to Dr.J.Abdul Jaleel, Mrs. Jubairiyath Beevi and all other Faculty members in Electrical and Electronics department of TKM College of Engineering, Kollam, India for their valuable support. REFERENCES [1] J.S.T. Looms, Insulators for High Voltages, Peter Peregrinus Ltd, 1988. [2]R.K. Aggarwal, A.T. Johns, J.A.S.B. Jayasinghe, W. Su An overview of the condition monitoring of overhead lines Electric Power Systems Research 53 (2000) 15 22 1988. [3]Yang Yang, Guangzhong Xie, Xiangdong Xu, Yadong Jiang A Monitoring System Design in Transmission Lines based on Wireless Sensor Networks Procedia 00 (2011) 000 000192 199 ICSGCE 2011: 27 30 September 2011, Chengdu, China. [4] Zhang Gang, Study on Electrical Switching Device Junction Temperature Monitoring System Based on ZigBee Technology, 2010 International Conference on Computer Application and System Modeling (ICCASM 2010) [5] Christos Xenakis, Danae Apostolopoulou, Angeliki Panou, Ioannis Stavrakakis, A Qualitative Risk Analysis for the GPRS Technology, 2008 IEEE/IFIP International Conference on Embedded and Ubiquitous Computing [6] Aryadevi Remanidevi Devidas, Maneesha Vinodini Ramesh, Wireless Smart Grid Design for Monitoring and Optimizing Electric Transmission in India, 2010 Fourth International Conference on Sensor Technologies and Applications [7] Degang Gan, Fan Liu, Lin Du, Yuming Liu, Research and Implementation of On-line Monitoring Techniques for High Voltage Equipments in Smart Grid, High Voltage Engineering and Application (ICHVE), 2010 International Conference on 11-14 Oct. 2010 [8] YANG Qi-ping, XU Dan-feng Li Meng-qun Development of an Power Transmission Line Online Monitoring System IEEE 2011. [9] Rezaei, H.F.; Sitter, N.; Kruger, A. Next generation system for realtime monitoring of rainfall,soil moisture and soil temperature IEEE Symposium on sensors.publication Year: 2011, Page(s): 70-75 BIOGRAPHY Sahad A received the B.Tech Degree (Electrical and Electronics) from Muslim Association College of Engineering, Trivandrum on 2007.He worked as Electrical Engineer in Saudi Arabia from January 2008 to October 2009.Later he joined Mohandas College of Engineering,Trivandrum and worked as Lecturer in Electrical Engineering till Aug 2011.Currently he is doing M.Tech (Electrical and Electronics-Industrial Instrumentation and Control) in TKM College of Engineering,Kollam. Copyright to IJAREEIE www.ijareeie.com 274