TDMoEthernet. Description



Similar documents
Loop-IP6700 TDMoEthernet

Loop-IP6702 TDMoEthernet

Loop-IP6700 TDMoEthernet

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-IP6510 Multiple WAN Router/Bridge

IPmux-1E TDM Pseudowire Access Gateway

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Optimux-134, Optimux-125

Optimux-134, Optimux-125

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

DXC Family. Multiservice Access Node FEATURES

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Loop-IP6416 IP-IMUX. Description

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

DataSMART 681, 696 and 698

Optimux-34, Optimux-25

FCD-E1E Managed E1 and Fractional E1 Access Device

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

TDM-over-IP Improving Backhaul efficiency

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

VALIANT COMMUNICATIONS LIMITED

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

F2400 FOM II Series Fiber Optic Modem Technical Manual

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET

ORION TELECOM NETWORKS INC. T1

WEB RANger-II Internet Access Router

FlexPoint T1/E1 Copper to Fiber Line Driver

Product Overview. Features CHAPTER

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

1Industrial Ethernet Switch

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

HARTING mcon 1000 Introduction and features

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

AM3440-A/B/C Access Mux. Description. Features

MPX100 Intelligent Ethernet Test Probe

Chapter 4 T1 Interface Card

24-Port Channelized E1/T1 Line Card Overview

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

Cisco Channelized T1/E1 and ISDN PRI Modules

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

CHRONOS. Ethernet Demarcation. Smart Access Network Device. Features. Introduction

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

Appendix A QUICK Specifications

Rack mounted telephone- and leased line modem for industrial applications

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

10/100/1000 Base-T to Gigabit Fiber Media Converter

TrueAlarm Fire Alarm Systems

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

IKS PoE Series. 24+4G-port Gigabit modular managed PoE+ Ethernet switches. Introduction. Industrial Ethernet Solutions. Features and Benefits

Long Range Ethernet Extender

EUSM - Ethernet Universal Service Module

IPmux-16L Hub-Site Pseudowire Access Gateway

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

T200, PTP/IEEE 1588 Grandmaster Clock and

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

INTRODUCTION TO MEDIA CONVERSION

PacketBand-V.35/X.21. Technical Specification 1. Connectivity Overview

LOOP-H 3300 MULTI RATE G.SHDSL DATA TRANSPORT USER'S MANUAL (Stand Alone - E1/ T1)

Dialogic I-Gate 4000 SIP Gateway

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

VePAL MX300. Platform Highlights. Key Features. 10GbE LAN/WAN and Gigabit Ethernet and Fast Ethernet Test Set. Metro Expert

SOLUTIONS FOR AN EVOLVING WORLD IMUX 2000 T1/E1 MDACS. Cross-Connect Switch IMUX 2000 T1/E1 1

CTP Series Circuit to Packet Platforms

Configuring E1 and T1 Interfaces

Cisco 24-Port Channelized T1/E1/J1 Circuit Emulation Over Packet and Channelized ATM Shared Port Adapter

HES-3106-RF Series Managed CPE Switch

These highly flexible interface cards facilitate several important applications:

T3 Mux M13 Multiplexer

Ethernet Link SGI-2424

Updated March 2013 UCC Ensuring the Reliability of the Electric Power Grid. T1/E1 Multiplexer with Common Logic Redundancy

P-Series: Purpose Built Business and Mobile Backhaul ONTs

DXC-8R/10A/30 Multiservice Access Nodes

NO SPECIFICATION SPECIFICATION COMPLIANCE RESPOND PROPOSED BY VENDOR

HDO700 P FIBRE OPTIC TRANSMITTER

FarSync TE1R. A Universal PCI adapter for E1 and T1 (G.703 / G.704) connections for Linux and Windows

Transcription:

Loop-IP6700 TDMoEthernet Description Loop-IP6700 TDMoEthernet is used to transport TDM traffic over IP network, in addition to Ethernet traffic. As the core communications network migrates from TDM to IP, the Loop-IP6700 provides a flexible and Feature 1U height WAN port One electric Ethernet (10/100 BaseT) or optical Ethernet (10/100 Base-FX) Tributary ports TDM interfaces low speed, up to 4 E1/T1 low speed, up to 2 DTE high speed, 1 E3/DS3 LAN interface: two 10/100 BaseT Ethernet/SNMP Power Single AC or DC power AC (100 to 240 Vac) DC (-20 to -72 Vdc) Inband management: through one time slot (64K bps) Bridging & Switching VLAN Max. 255 VLAN Q-in-Q Packet transparency (up to 1916 bytes) QoS User configurable CoS User configurable ToS in outgoing IP frame Max. 340ms Packet Delay Variation Jitter buffer size: 3 ms to 512 ms Min. packetization (pseudowire) latency < 2 ms Supports SNTP Built-in BERT for E1/T1 Jitter & Wander PPM: per G.823 Traffic PPB: per G.823 Synchronous Multi-color LED indicators Alarm relay Management port and interface LCD and keypad Console port with VT100 menu SNMP port: Embedded SNMP Telnet LoopView GUI cost effective choice for the transport of legacy TDM signals. On the WAN side, the Ethernet interface can be 10/100M electric or optical Ethernet. On the tributary side, the TDM ports can be multiple E1, T1, and DTE, or single E3/DS3, each with timing preserved. The Ethernet port can be 10/100 BaseT. The Loop-IP6700 has built-in AC or DC power. Management choices include console port, Ethernet port, and SNMP port, in addition to Inband management for communication with remote management centers. For transport of TDM signals E1, T1, E3, DS3, Jitter and Wander adheres to G.823 Traffic and G.823 Synchronous. 1

Ordering Information To specify options, choose from list below: Note: RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code. Model (non RoHS compliant) Loop-IP6700-S-EH- PPM-pp-add Loop-IP6700-S-EL- PPM-aa-bb-cc-dd-ppadd-G Loop-IP6700-S-OH- PPM-pp-add Loop-IP6700-S-OL- PPM-aa-bb-cc-dd-ppadd-G Loop-IP6700-S-EH- PPB-pp-add Loop-IP6700-S-EL- PPB-aa-bb-cc-dd-ppadd-G Loop-IP6700-S-OH- PPB-pp-add Accessories User s Manual Model (RoHS compliant) Loop-IP6700-S-EH- PPM-pp-add-G Loop-IP6700-S-EL- PPM-aa-bb-cc-dd-ppadd Loop-IP6700-S-OH- PPM-pp-add-G Loop-IP6700-S-OL- PPM-aa-bb-cc-dd-ppadd Loop-IP6700-S-EH- PPB-pp-add-G Loop-IP6700-S-EL- PPB-aa-bb-cc-dd-ppadd Loop-IP6700-S-OH- PPB-pp-add-G Loop-IP6700-S-OL- PPB-aa-bb-cc-dd-ppadd Loop-IP6700-S-OL- PPB-aa-bb-cc-dd-ppadd-G Description IP6700 with G.823 traffic, an electric Ethernet WAN port, a SNMP port, one E3/DS3 high speed interface and one LAN interface IP6700 with G.823 traffic, an electric Ethernet WAN port, a SNMP port, low speed interfaces described below and one LAN interface IP6700 with G.823 traffic, an optical Ethernet WAN port, a SNMP port, one E3/DS3 high speed interface and one LAN interface. SFP optical module is not included. IP6700 with G.823 traffic, an optical Ethernet WAN port, a SNMP port, low speed interfaces described below and one LAN interface. SFP optical module is not included. IP6700 with G.823 synchronous, an electric Ethernet WAN port, a SNMP port, one E3/DS3 high speed interface and one LAN interface IP6700 with G.823 synchronous, an electric Ethernet WAN port, a SNMP port, low speed interfaces described below and one LAN interface IP6700 with G.823 synchronous, an optical Ethernet WAN port, a SNMP port, one E3/DS3 high speed interface and one LAN interface. SFP optical module is not included. IP6700 with G.823 synchronous, an optical Ethernet WAN port, a SNMP port, low speed interfaces described below and one LAN interface. SFP optical module is not included. Loop-IP6700-UM Loop-IP6700-UM User s Manual (paper hard copy-optional). A CD version of the manual is already included as standard equipment. Power Cord (All power cords are RoHS compliant) Loop-ACC-PC-USA Loop-ACC-PC-USA AC power cord for Taiwan/America Loop-ACC-PC-EU Loop-ACC-PC-EU AC power cord for Europe Loop-ACC-PC-UK Loop-ACC-PC-UK AC power cord for UK Loop-ACC-PC-AUS Loop-ACC-PC-AUS AC power cord for Australia Loop-ACC-PC-CH Loop-ACC-PC-CH AC power cord for China SFP Optical Module (All SFP Optical Modules are RoHS compliant) Multimode optical module with dual uni-directional MHBTW MHBTW fiber, 155M, 1310 nm, LC optical connector, 2km reach (11dBm) PHB3W PHB3W 155M, 1310 nm, LC optical connector, 30 km reach (19dBm) PHB5W PHB5W 155M, 1310 nm, LC optical connector, 50 km reach PHCUW PHCXW PHB3D PHCUW PHCXW PHB3D (30dBm) 155M, 1550 nm, LC optical connector, 100 km reach (30dBm) 155M, 1550 nm, LC optical connector, 120 km reach (35dBm) 155M, 1310 nm, LC optical connector with Digital Diagnostic Monitoring, 30 km reach (19dBm) Note - Use 2 fibers for all SFP Optical Modules 2

PHB5D PHB5D 155M, 1310 nm, LC optical connector with Digital Diagnostic Monitoring, 50 km reach (30dBm) PHC8D PHC8D 155M, 1550 nm, LC optical connector with Digital Diagnostic Monitoring, 80 km reach (0dBm) PHCUD PHCUD 155M, 1550 nm, LC optical connector with Digital Diagnostic Monitoring, 100 km reach (30dBm) PHCXD PHCXD 155M, 1550 nm, LC optical connector with Digital Diagnostic Monitoring, 120 km reach (35dBm) NOTE: 1. For other special optical modules, please contact your nearest Loop sales representative. 2. * High Speed for E3/DS3 only (E3/DS3 software programmable) * Low Speed for T1, E1 and DTE 3. PPM = G.823 Traffic, PPB = G.823 Synchronous Where aa, bb = select from list below or leave this area blank E75 for 75 ohm BNC E1 interface port E120 for 120 ohm Twisted Pair RJ48C E1 interface port T1 for T1 interface port Where cc and dd are optional = select from list below or leave this area blank E75 for 75 ohm BNC E1 interface port E120 for 120 ohm Twisted Pair RJ48C E1 interface port T1 for T1 interface port 22 for V.35 DTE interface with DB25 connector 33 for EIA530 DTE interface with DB25 connector 44 for X.21 DTE interface via DB25P to DB15S (1-feet) conversion cable 66 for V.36 / RS449 DTE interface via DB25P to DB37S (1-feet) conversion cable 77 for RS422 / V.11 DTE interface with DB25 connector pp = DC for -20 to -72 Vdc power source AC for 100 to 240 Vac power sources (For AC choose an appropriate power cord) add= Front panel with LCD and keypad Examples: Loop-IP6700-S-EH-PPM-AC-LCD) A high speed unit with G.823 traffic, electric Ethernet WAN port, one E3/DS3, 100 to 240 Vac power and LCD. Loop-IP6700-S-EL-PPM-E75-E75-22-22-AC-LCD A low speed unit with G.823 traffic, electric Ethernet WAN port, two E75 ports, two V.35 DTE ports, 100 to 240 Vac power and LCD Loop-IP6700-S-OH-PPB-AC A high speed unit with G.823 synchronous, an optical Ethernet WAN port, one E3/DS3 and 100 to 240 Vac power. Loop-IP6700-S-OL-PPB-E120-E120-22-22-AC A low speed unit with G.823 synchronous, an optical Ethernet WAN port, two E120 ports, two V.35 DTE ports and 100 to 240 Vac power. 3

Loop-IP6700 TDMoEthernet Product Specifications SFP Optical Module Specification SFP Optical Fiber Direction Module Wavelength (nm) 4 Distance (km) Power (dbm) MHBTW Dual uni-directional 1310 LC without DDM 2 11 PHB3W Dual uni-directional 1310 LC without DDM 30 19 PHB5W Dual uni-directional 1310 LC without DDM 50 30 PHCUW Dual uni-directional 1550 LC without DDM 100 30 PHCXW Dual uni-directional 1550 LC without DDM 120 35 PHB3D Dual uni-directional 1310 LC with DDM 30 19 PHB5D Dual uni-directional 1310 LC with DDM 50 30 PHC8D Dual uni-directional 1550 LC with DDM 80 0 PHCUD Dual uni-directional 1550 LC with DDM 100 30 PHCXD Dual uni-directional 1550 LC with DDM 120 35 NOTE: For other special optical modules, please contact your nearest Loop sales representative. Electric Ethernet WAN Interface Interface 10/100 BaseT RJ45 Optical Ethernet WAN Interface Speed 100 Base-FX SFP 3.3V E1 Tributary Interface Line Rate 2.048M bps ± 50 ppm Input Signal ITU G.703 Framing ITU G.704 (CRC: on/off, CAS: on/off, Output Signal ITU G.703 unframed) Jitter ITU G.823 Line Code AMI/HDB3 Electrical 75 ohm coax/120 ohm twisted pair BNC and RJ48C T1 Tributary Interface Line Rate 1.544M bps ± 32 ppm Input Signal DS-1 from 0 db to -26 db w/albo Framing D4/ ESF/ ESF&T1.403/ NONE (clear Output Signal DSX-1, DS-1 channel) Surge Protection FCC Part 68 Sub-Part D Line Code AMI / B8ZS Pulse Template Per AT&T TR 62411 RJ48C NOTE: E1/T1 (jumper selectable) DTE (V.35/EIA530/X.21/V.36/RS449/RS422/V.11) Tributary Interface Data Rate n x 56K bps (n= 1 to 31) or n x 64K bps (n= 1 to 32) DB25S for V.35 DB25S for EIA530 DB15S for X.21 via DB25P to DB15S conversion cable DB37S for V.36/RS449 via DB25P to DB37S conversion cable DB25S for RS422/V.11 E3 Tributary Interface Data Rate 34.368M bps ± 4.6 ppm Framing Unframed Line Code HDB3 Output Mask ETS 300 689 Sec.4.2.1.2 ITU G.703 BNC connector Total Ports 1 Impedance 75 ohm coax Jitter I ITU G.824 DS3 Tributary Interface Data Rate 44.736M bps ± 4.6 ppm Framing Unframed Line Code B3ZS Output Mask Bellcore GR-499-core BNC connector Total Ports 1 Impedance 75 ohm coax Jitter ITU G.824 NOTE: E3/DS3 (software selectable) Ethernet Switch VLAN packet transparency (up to 1916 bytes) Max. 255 VLAN Supports Q-in-Q User configurable CoS User configurable ToS in outgoing IP frame

LAN Tributary Interface Number of Ports 2 Speed 10/100 BaseT RJ45 Packet Delay Variation For E1: up to 256 ms For Framed T1: up to 256 ms For Unframed T1: up to 340 ms For Framed T1 with CAS: up to 192 ms For E3: up to 60 ms For DS3: up to 45 ms SNTP SNTP client support Sync with up to 2 time servers Clock Source Primary Clock Secondary Clock External Clock Input Signal Alarm Relay Alarm Relay Internal, tributary port (A, B, C or D), WAN port, external (for low speed tributary port E1/T1/DTE only, manufacture option) Internal, tributary port (A, B, C or D), WAN port, external (for low speed tributary port E1/T1/DTE only, manufacture option) E1 (2.048M bps), 2M bps, 120 ohm BNC Fuse alarm, performance alarm 3 pin terminal block Network Management Console Port SNMP Port Electrical RS232 interface Protocol Telnet (VT100) and Embedded SNMP Protocol Menu driven VT-100 terminal RJ45 at front panel DB9, female, DCE Inband Management Through any one time slot (64K bps) for low speed ports (E1/T1) with frame mode only HDLC management protocol Performance monitors (T1, E1) Performance Store The last 24 hours performance in 15-minute intervals Monitor Registers Line, user and remote site Performance Reports Date &Time, Error second, Unavailable second, Bursty error second, severe error second, controlled slip second, and loss of frame count Alarm History Date & time, alarm type(i.e. master clock loss, RAI, AIS, LOS, BPV, ES, CSS) ursty seconds, Threshold severely errored Second Diagnostics test (T1, E1) Loopback Line loopback, payload loopback and local loopback Remote Loopback Payload loopback Front Panel LCD and Keypad LEDs Power Single AC power or DC power. AC: 100 to 240 Vac, 50/60 Hz DC: -20 to -72 Vdc Power Consumption: 10W Max Physical and Environmental Dimensions 212.6 x 44 x 197 mm. (W x H x D) Temperature 0-50 C Humidity 0-95% RH (NON-CONDENSING) Mounting Desk-top stackable, wall mount Certification EMC Safety EN55022 Class A, EN50024, EN300 386, FCC Part 15 Subpart B Class A IEC60950-1(CB), EN60950-1(CE) 5

Standard Compliance ITU G.703, G.704, G.706, G.823, G.824, G.826, V.11, PWE3 IETF TDMoIP, SAToP, CESoPSN, 802.1p/Q Application Illustration 6

IP6700 Clock Option NOTE: If independent clocks are used with T1 signals and the WAN port is transported over a wireless network, a possibility of occasional 1 second pattern loss exists IP6700 Extension Phone System 7

IP6700 on VPN Network Data Comm for Business, Inc. 2949 CR 1000 E Dewey, IL 61840 Voice 8004DCBNET (800.432.2638) Fax 217.897.1331 Info www.dcbnet.com/contact.html Web www.dcbnet.com 8