OTICON RIA pro OTICON RIA

Similar documents
PRODUCT INFORMATION oticon ALtA PRo oticon ALtA

Essential hearing technology, shaped for life

Experience hearing the way you prefer

Hearing Solutions. Feature Chart 4 Feature Summary 6. Feature Chart 14 Feature Summary 16

Savia ArtTM. Product Line. Product information

Phonak Naída Q. Product information

360 Programming Guide

Technical Manual Oria Opera Plus ITC Beltone Oria O35/ Oria Opera Plus ITC Beltone Oria O35 HPG / Oria Opera Plus HPG ITC

Pricing Modifier. Informational Modifier

Hearcentres Guide to Hearing Aid Terminology

Prescriptive Fitting Algorithms: New and Improved! Michelle Mattingly, Au.D. and Lisa Perhacs, Au.D.

Wisconsin Department of Health & Family Services Division of Disability and Elder Services Bureau of Aging & Long Term Care Resources

The advantage in the ear. A Phonak, customized

Everybody has the right to

How To Fit A Super Power Hearing Instrument

instruction guide Version 2.2 Table of contents

A Hearing Aid Primer

Bone Conduction Implants Recent Changes in Surgical Techniques, Hearing Technology & Implant Options

Testing FM Systems on the FP35 Hearing Aid Analyzer -1-

Step-by-Step RECD Guide

Pediatric Fitting Guide

USER INSTRUCTIONAL BROCHURE

FM-CI Cochlear Implant Adaptor Instructions for Use

Hearing Aid FAQs from the American Academy of Audiology 2006 American Academy of Audiology

Safe Listening! How I Enjoy My Music and Avoid a Silent Future (ITU and WHO) Brian Copsey

Widex Dex FAQ. General

Magnitude of Hearing Loss and Open Ear Fittings

Enjoy the sound of life. Life sounds brilliant. Pure & Carat. usa.siemens.com/binax

ReSound Aventa 3.7 fitting software supports all ReSound instruments built on the ReSound Range, Range II and Smart Range chips.

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

Learning Objective. To learn about current technological interventions that allow children with hearing loss to access auditory information

The E-Scope Electronic Stethoscope Catalog of Products April 25, 2012

5th Congress of Alps-Adria Acoustics Association NOISE-INDUCED HEARING LOSS

Cisco compatibility. Sennheiser Communications solutions overview

Fitting guide.

Generic - Hearing Loop - (AFILS) U.S. System Specification

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Factors to consider when choosing a hearing aid

Integrating best practice in hearing care

Ponto Freedom of choice in bone anchored hearing care. Product Catalog 2010/2011

Hearing Aid Styles. Siemens Phonak Widex Starkey. Sonic Oticon Unitron. Resound

HCPCS CODING REFERENCE CHART

DIAGNOSTIC TESTING GUIDELINES for Audiology

4.2. Desktop Fitting Guide. Content. August 2015

By Michael Block, PhD

The Role of the Educational Audiologist Introduction:

InSTrUcTIonS FOR USE. designrite

Edited by Victor de Andrade Page 1

EVOline Multimedia Modules

TecEar s Top Ten ALD Picks

Stream Boost: All About That Bass

#

USER GUIDE PRO-EQ PLATINUM

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Audiology. Hearing Aids

ReSound Vea Mini, standard and power

Custom Hearing Aids. In-The-Ear, In-The-Canal, Completely-In-Canal. Operations Manual

USER GUIDE ELLIPSE AURA RETAIL

Hearing Aid Compatibility With Digital Wireless Cell Phones:

Say hello to the world's smartest hearing aids

Generating Element. Frequency Response. Polar Pattern. Impedance. Output Level

Contents. Document information

Infant Hearing Program. A parent s guide to hearing aids

GUIDELINES FOR HEARING AID FITTING FOR ADULTS

Mesa Arista Cierra Sequel Endeavour

User Guide SmartAid and SmartAid Digital BTE Hearing Aids

As each aid is set specifically for either the right or the left ear you should make sure not to mix them up, so we have marked:

Counseling parents for the use of hearing aids

Ponto The bone anchored hearing system from Oticon Medical. Audiological Manual. Ponto, Ponto Pro & Ponto Pro Power

Hear The Future...Now! SIEM-2T/SIEM-2R

Pediatric Audiological Mission. A better future for every child with hearing loss

Instruction manual EAR SET 1 EAR SET 4

Hearing Aids. What Is a Hearing Aid? How Common Is Hearing Loss and What Causes It? How Do We Hear?

6/18/2015. Bone Conduction Implants Recent Changes in Technology, Implant Options and Surgical Techniques Rebecca Cihocki AuD Clinical Trainer

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

3M E-A-RTONE 3A and 5A Audiometric Insert Earphones

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

Phonak Wireless Communication Portfolio

Reader ExSilent Q - v.2.0. ExSilent Q - Reader

MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

How To Buy A Call Center Headset

ASU Speech & Hearing Clinic Hearing Aid Services

Cochlear Implant and Associated Technologies for Hearing

Hearing Aid Service Provider. General Guidelines

Wireless. with Personal Mix Control and EP3 Dynamic Earphones

Full workday of talk time 8 hours wideband and 12 hours narrowband Two years warranty for peace of mind

Samuel R. Atcherson, Ph.D.

Moxi behind-the-ear (BTE) hearing aid guide

H203D 中文 GB Version 1

Technical Note Series

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

TV & Assistive Listening Devices

evolution wireless G3 evolution wireless Wireless Microphone Systems evolution wireless G3 Sets:

USER GUIDE. Thank you for choosing Ovation Hearing and congratulations on taking control of your hearing health.

User Manual. For additional help please send a detailed to Support@phnxaudio.com. - 1 Phoenix Audio Technologies

Getting Started STEP 1

Transcription:

product information Oticon Ria is built on the new Inium platform and is our best performing hearing solution in the essential category. The audiological features in Ria provide users essential listening performance in several situations and factor in individual listening preferences and patient needs. The Ria family of instruments range from compact in-the-ear styles, including the Invisible-In-the-Canal (IIC) design for users looking for ultimate discretion, and ITE for severe hearing losses, to a broad palette of BTE and RITE styles. RITE instruments use Oticon s minifit receivers and the BTE instruments use the new Corda minifit thin tubes. Both of these use the minifit soft domes and custom ear pieces. FITTING RANGE HL - 125 2 1k Ria solutions are appropriate for users with mild to severe-to-profound hearing losses. YouMatic Essential YouMatic is a personal automatic system programmed to the patient s individual needs and sound preferences. YouMatic Essential makes it easy to adjust the instrument s reaction and response performance to better match patients preferences for comfort, support and clarity in sound. Free Focus Essential Free Focus Essential switches seamlessly between two modes Optimized and Split directionality with the possibility to manually switch to Full directionality in very difficult listening situations. Optimized is a new mode of directionality specifically developed to improve speech understanding by mimicking the natural front focus of the pinna to provide the desired access to the speech signal. Inium feedback shield Inium feedback shield is an effective feedback protection system implemented on the new Oticon Inium platform. Inium feedback shield is a hybrid system combining two anti-feedback principles designed to both prevent and suppress feedback without superimposing artifacts onto the signal or sacrificing audibility. Inium feedback shield deploys the best combination of real time phase inversion and frequency shifting to deliver great sound quality at all times. Family Features YouMatic Essential Binaural Synchronization Binaural PB Coordination Fitting Bandwidth 8 khz Inium feedback shield Free Focus Essential Activity Analyzer T-coil AutoPhone Program Modulation-based Noise Management Single Band ectionality NAL-NL1, NAL-NL2 and DSL v5.a m[i/o] Flexible minifit receiver system ConnectLine enabled DAI input and FM option In-situ audiometry (Genie) INIUM WIRELESS

PRODUCT OVERVIEW r ite styles c u stom styles - HL 125 2 1k - HL 125 2 1k - HL 125 2 1k - HL 125 2 1k - HL 125 2 1k - HL 125 2 1k Custom mold Bass & Power dome OSPL (peak) (peak) bte styles - HL 125 2 1k - HL 125 2 1k Open dome - Custom mold HL 125 2 1k Corda minifit Ear simulator 119 126 1 135 115 127 132 131 126 135 2cc coupler 9 117 121 127 5 118 124 121 117 126 Ear simulator 49 59 64 71 46 65 66 62 61 68 2cc coupler 38 54 62 35 55 57 53 51 IIC CIC ITC ITE - Half Shell ITE - Full Shell Battery size minirite RITE minibte BTE13 312 13 312 312 312 13 75-135 1-2 - - 115-1 85-1 Fitting levels Battery life (h)* Wireless ectional Volume control Telecoil AutoPhone Connectline compatible FlexConnect Mini FlexConnect Mini FlexConnect Programming shoe Cable #3 directly Programming shoe Program control FM compatible Programming interface, cable #3 FlexConnect Mini Default Option c u stom styles Wax protection Receiver in all instruments ProWax Microphone in battery instruments. T-Cap Microphone in 312 and 13 battery instruments. O-Cap Instruments with 312 battery may be produced with horizontal b attery drawer depending on ear geometry. Four receiver sizes are available for custom products corresponding to fitting levels. The receiver is selected at Oticon based on the audiogram. Power options are indicated on the order form. * Real usage battery life is shown as an estimated interval based on measurements with variable amplification settings and variable input levels. gene r al info B T E / R I T E styles Tamper resistant battery drawer Available in 7 colors for all BTE and RITE styles. DAI adaptor AP (available for BTE13 and RITE styles). Dedicated FM receiver Amigo R12 (available for BTE13 and RITE styles). FM adaptor FM 9 (available for BTE13 styles) Compatible with Amigo R1, R2 and other universal r eceivers (not recommended for instruments using 312 batteries). FITTING LEVELS Custom RITE BTE 2 3

PRODUCT OVERVIEW Oticon Ria instruments are programmed using the Genie 14.1 fitting software or higher compatible with NOAH 3 or higher. They can be programmed using either programming cables #3 or wirelessly using nearcom (TM#1). general fitting Wireless fitting - nearcom nearcom provides a wireless link between NOAHlink and one or two wireless-enabled hearing instruments. In addition, nearcom provides a pass-through connection to accommodate programming cables and replaces the existing NOAHlink neck loop (not availble for non-wireless products; consult order form for options). MODEL FEATURES Oticon Ria Pro Oticon Ria Fitting formulas NAL, DSL NAL, DSL YouMatic Essential Essential Binaural Synchronization (automatics) Yes No Binaural Coordination (PB operations) Yes Yes Fitting Bandwidth* 8 khz 8 khz Free Focus Essential Essential Inium feedback shield Yes Yes Fitting Bands 6 4 * Bandwidth accessible for gain adjustments during fitting RITE STYLES Receiver unit Receiver wire Receiver connector to instrument Must use minifit receivers. Select between three receiver types with different output performance, labeled according to fitting capabilities:, 85 and. and 85 available in lengths from size 5. available in lengths from size 1 5. Separate wires connect Power Receiver molds () to RITE instruments, available in lengths from size 1 5. Type C1 (marked on packaging). Ear Pieces Wax protection Must use minifit ear pieces. Open domes in size 6, 8 and mm. Bass domes, single vent in size 6, 8, and 12 mm. Bass domes, double vent in size 6, 8, and 12 mm. Power domes in size 6, 8, and 12 mm. Custom ear pieces are available as LiteTip and Micro Mold (requires taking an impression). ProWax minifit in all minifit receivers. ProWax in Power Receiver Mold, LiteTip and Micro Mold. rite & bte styles Chroma Beige 94 Terracotta COLOR SELECTION 93 Chestnut Brown 44 Silver 91 Silver Grey 92 Steel Grey 63 Diamond Black custom styles BTE STYLES 1 Pink 2 Tan 3 Medium Brown 4 Dark Brown 5 Black (IIC faceplate only) Sound hook Interchangeable standard and child hook Damper Damping plug available for BTE13 85 Thin tubes Corda minifit (.9 mm tubes) for minibte 85 and BTE13 85. Corda minifit Power (1.3 mm tubes) for BTE13. Thin tubes are available in lengths from size -1 to 4. Style specific adapters must be used when connecting thin tubes. Ear pieces Wax Protection Must use minifit ear pieces for Corda minifit. Open domes in size 6, 8 and mm. Bass domes, single vent in size 6, 8, and 12 mm. Bass domes, double vent in size 6, 8, and 12 mm. Power domes in size 6, 8, and 12 mm. Custom ear pieces are available as a Corda Mold (requires taking an impression). ProWax for Corda Mold. power Receiver mold 6 Clear 4 5

minirite minirite 85 IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL directional mode is used unless Nera_mRiteS_FOG_711 13 3 13 str_lo 16:4:4 Nera_mRiteS_MPO_711 13 3 13 str_lo 16:5:49 Nera_mRiteS_FOG_2cc 13 3 13 str_lo 16:3:35 Nera_mRiteS_MPO_2cc 13 3 13 str_lo 16:5:13 directional mode is used unless Nera_mRiteM_FOG_711 13 3 13 str_lo 15:53:39 Nera_mRiteM_MPO_711 13 3 13 str_lo 15:54:47 Nera_mRiteM_FOG_2cc 13 3 13 str_lo 15:53:15 Nera_mRiteM_MPO_2cc 13 3 13 str_lo 15:54:26 Nera_mRiteS_RTG_711 13 3 13 str_lo 16:7:29 Nera_mRiteS_RTG_2cc 13 3 13 str_lo 16:7:5 Nera_mRiteM_RTG_711 13 3 13 str_lo 15:57:11 Nera_mRiteM_RTG_2cc 13 3 13 str_lo 15:56:39 OSPL Telecoil output () (Input ) ma/m field Hz Hz 115 5 1 8 3 46 35 37 29 34 26-7 Hz - Hz 21 16 29 24 1.1 ma 1.3 ma OSPL Telecoil output () (Input ) ma/m field Hz Hz 127 118 123 114 119 114 65 55 51 43 52 47 44 38 - Hz -7 Hz 2.4 % <2 % 25 18 33 25 1.1 ma 1.2 ma IRIL (IEC 118-13-11) 1 // MHz: 43/26/<18 IRIL (IEC 118-13-11) 1 // MHz: 45//25 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 6 7

minirite rite IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL 1 1 directional mode is used unless Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. Nera_mRiteP_RTG_711 13 3 13 str_lo 16:1:57 Nera_mRiteP_FOG_711 13 3 13 str_lo 15:59: Nera_mRiteP_MPO_711 13 3 13 str_lo 16::15 Nera_mRiteP_RTG_2cc 13 3 13 str_lo 16:1:7 Nera_mRiteP_FOG_2cc 13 3 13 str_lo 15:58:28 Nera_mRiteP_MPO_2cc 13 3 13 str_lo 15:59:53 directional mode is used unless Acoustic input: Nera_mRiteS_MPO_711 13 3 13 str_lo 16:5:49 Nera_mRiteS_FOG_711 13 3 13 str_lo 16:4:4 Nera_RiteS_MT_711 13 3 13 str_lo 16:13:52 Acoustic input: Nera_mRiteS_MPO_2cc 13 3 13 str_lo 16:5:13 Nera_mRiteS_FOG_2cc 13 3 13 str_lo 16:3:35 Nera_RiteS_MT_2cc 13 3 13 str_lo 16:13:19 OSPL Telecoil output () (Input ) ma/m field Hz Hz 132 124 131 124 126 121 66 57 56 49 58 52 44 - Hz -7 Hz 2.5 % <2 % 22 16 25 1.1 ma 1.3 ma OSPL Telecoil output () (Input ) ma/m field Hz Hz 115 5 1 8 3 46 35 37 29 34 26-7 Hz - Hz 65-85 - - 82/82 21 16 29 24 1.1 ma 1.3 ma IRIL (IEC 118-13-11) 1 // MHz: 46/28/23 IRIL (IEC 118-13-11) 1 // MHz: 27/46/51 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 8 9

rite 85 rite IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL 1 1 directional mode is used unless Acoustic input: Nera_mRiteM_MPO_711 13 3 13 str_lo 15:54:47 Nera_mRiteM_FOG_711 13 3 13 str_lo 15:53:39 Nera_RiteM_MT_711 13 3 13 str_lo 16::25 Acoustic input: Nera_mRiteM_MPO_2cc 13 3 13 str_lo 15:54:26 Nera_mRiteM_FOG_2cc 13 3 13 str_lo 15:53:15 Nera_RiteM_MT_2cc 13 3 13 str_lo 16:9:52 directional mode is used unless Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. Acoustic input: Nera_mRiteP_MPO_711 13 3 13 str_lo 16::15 Nera_mRiteP_FOG_711 13 3 13 str_lo 15:59: Nera_RiteP_MT_711 13 3 13 str_lo 16:12:11 Acoustic input: Nera_mRiteP_MPO_2cc 13 3 13 str_lo 15:59:53 Nera_mRiteP_FOG_2cc 13 3 13 str_lo 15:58:28 Nera_RiteP_MT_2cc 13 3 13 str_lo 16:11:39 OSPL Telecoil output () (Input ) ma/m field Hz Hz 127 118 123 114 119 114 65 55 51 43 52 47 44 38 - Hz -7 Hz 79-99 - - 95/95 2.4 % <2 % 25 18 33 25 1.1 ma 1.2 ma OSPL Telecoil output () (Input ) ma/m field Hz Hz 132 124 131 124 126 121 66 57 56 49 58 52 44 - Hz -7 Hz 85-5 - - 1/1 2.5 % <2 % 22 16 25 1.1 ma 1.3 ma IRIL (IEC 118-13-11) 1 // MHz: 19/41/36 IRIL (IEC 118-13-11) 1 // MHz: <17/49/39 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 11

minibte 85 BTE13 85 IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL directional mode is used unless 1 Thin tube (size 1/.9) Nera_mBTE_711_MPO_update_1 12 11 13 3 13 str_lo 15:44:48 Nera_mBTE_711_gain_update_1 12 11 13 3 13 str_lo 15:47: 1 Thin tube (size 1/.9) Nera_mBTE_2cc_MPO_update_1 12 11 13 3 13 str_lo 15:45:27 Nera_mBTE_2cc_gain_update_1 12 11 13 3 13 str_lo 15:47:45 directional mode is used unless Thin tube (size 1/.9) Nera_BTE13_MPO_711 13 3 13 str_lo 15:26:14 Nera_BTE13_gain_711 13 3 13 str_lo 15:24:21 Thin tube (size 1/.9) Nera_BTE13_MPO_2cc 13 3 13 str_lo 15:22:49 Nera_BTE13_gain_2cc 13 3 13 str_lo 15:23:53 Nera_711_frq_response 13 3 13 str_lo 15:42:51 Nera_2cc_frq_response 13 3 13 str_lo 15:42:24 Acoustic input: Nera_BTE13_MT_711 13 3 13 str_lo 15:29:49 Acoustic input: Nera_BTE13_MT_2cc 13 3 13 str_lo 15:28:48 OSPL Telecoil output () (Input ) ma/m field Hz Hz 131 (122*) 121 (117*) 126 (114*) (5*) 119 (116*) 118 (9*) 62 (61*) 53 (57*) (39*) 44 (*) (52*) 46 (*) 43 41-7 Hz -6 Hz 22 17 29 25 1.1 ma 1.2 ma OSPL Telecoil output () (Input ) ma/m field Hz Hz 126 (126*) 117 (123*) 121 (8*) 114 (*) 116 (116*) 113 (6*) 61 (63*) 51 (59*) (36*) 43 (28*) 49 (52*) 44 (41*) 43 36-7 Hz - Hz 79-99 - - 94/94 23 18 32 27 1.1 ma 1.1 ma 1.1 ma 1.1 ma 12 * IRIL (IEC 118-13-11) 1 // MHz: <18/24/36 * For instruments fitted with Corda minifit ** Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment * Size 13 (IEC PR48) IRIL (IEC 118-13-11) 2 // MHz: 24/48/45 * For instruments fitted with Corda minifit ** Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 13

BTE13 Custom 75 (iic only) IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL directional mode is used unless Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. 1 Thin tube (size 1/1.3) Acoustic input: Nera_BTE13P_MPO_711 13 3 13 str_lo 15:32:34 Nera_BTEP_gain_updateCorda_711 13 3 13 str_lo 15:36:39 Nera_BTE13P_MT_711 13 3 13 str_lo 15:34:9 1 Thin tube (size 1/1.3) Acoustic input: Nera_BTE13P_MPO_2cc 13 3 13 str_lo 15:31:55 Nera_BTEP_gain_updateCorda_2cc 13 3 13 str_lo 15:35:54 Nera_BTE13P_MT_2cc 13 3 13 str_lo 15:34:48 All measurements are made on instruments with ProWax receiver and T-Cap microphone protection. Acoustic input: P84_Intiga i_8_711_ospl 21 11 11 str_lo 13:25:13 Nera Ria_Pro_IIC_FOG_711_S 14 13 kbn_tjn 16:29:51 Nera Ria_Pro_IIC_Freqdb_711_S 14 13 kbn_tjn 16:31:18 Acoustic input: P84_Intiga i_8_2cc_ospl 21 11 11 str_lo 13:24:55 P84_Intiga i_8_2cc_fog 2 1 12 str_lo 11:1:35 P84_Intiga i_8_2cc_fresp 2 1 12 str_lo 11:4:22 OSPL Telecoil output () (Input ) ma/m field Hz Hz 135 (132*) 126 (128*) 128 (116*) (8*) 122 (121*) (115*) 68 (66*) (62*) (44*) 52 (36*) 57 (56*) 53 (49*) 53 43-7 Hz - Hz 89-9 - - / 19 16 29 26 1.1 ma 1.1 ma 1.1 ma 1.1 ma OSPL Telecoil output () (Input ) ma/m field Hz Hz 121 9 111 3 9 3 45 35 41 33 34 - Hz -7 Hz <2 % 2 % 21 18.7 ma.7 ma.7 ma.7 ma 14 * Size 13 (IEC PR48) IRIL (IEC 118-13-11) 2 // MHz: 24/48/45 * For instruments fitted with Corda minifit Power ** Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment (Size, IEC PR) IRIL (IEC 118-13-11) 135 // MHz: 14/19/< * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: Custom instruments may be built with a reduced maximum gain to optimize size and performance for the individual. 15

Custom 75 Custom 85 IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL All measurements are made on instruments with ProWax and T-Cap or O-Cap protection. directional mode is used unless otherwise stated. Nera ITC75_FOG_711 15 3 13 str_lo 15:14:22 Nera ITC75_MPO_711 15 3 13 str_lo 15:15:41 Nera ITC75_FOG_2cc 15 3 13 str_lo 15:13:11 Nera ITC75_MPO_2cc 15 3 13 str_lo 15:15:18 All measurements are made on instruments with ProWax and T-Cap or O-Cap protection. directional mode is used unless otherwise stated. Nera ITC85_FOG_711 15 3 13 str_lo 15::34 Nera ITC85_MPO_711 15 3 13 str_lo 15:22:36 Nera ITC85_FOG_2cc 15 3 13 str_lo 15:19:41 Nera ITC85_MPO_2cc 15 3 13 str_lo 15:22: Acoustic input: Nera ITC75_MT_711 15 3 13 str_lo 15:17:38 Acoustic input: Nera ITC75_MT_2cc 15 3 13 str_lo 15:16:45 Acoustic input: Nera ITC85_MT_711 15 3 13 str_lo 15:23:59 Acoustic input: Nera ITC85_MT_2cc 15 3 13 str_lo 15:23:28 OSPL Telecoil output () (Input ) ma/m field Hz Hz 119 9 112 4 5 49 38 43 35 41 35 36 27-7 Hz -7 Hz 73-93 - - 82/82 2. % <2 % 2. % <2 % 3. % 2. % 22 31 29 OSPL Telecoil output () (Input ) ma/m field SPLITS L / R Hz Hz 126 117 119 111 117 113 59 51 43 45 44 37-72 Hz - Hz 81-1 - - / 2. % <2 % 2. % <2 % 3. % 2. % 22 19 32 29 Size: (IEC PR) / 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 118-13-11) 135/1/2 // MHz: 28/44/37 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: Custom instruments may be built with a reduced maximum gain to optimize size and performance for the individual. Size: (IEC PR) / 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 118-13-11) 125/1/2 // MHz: 21/39/<14 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: Custom instruments may be built with a reduced maximum gain to optimize size and performance for the individual. 16 17

Custom Custom IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). IEC 118- (1983) and 711 (1981) and DIN 455. ANSI S3.22 (3) and S3.7 (1995), IEC 118-7 (5) and IEC 318-5 (6). OSPL OSPL OSPL OSPL All measurements are made on instruments with ProWax and O-Cap protection. directional mode is used unless otherwise stated. 1 Acoustic input: Nera ITC_MPO_711 15 3 13 str_lo 15:27:34 Nera ITC_FOG_711 15 3 13 str_lo 15:26:14 Nera ITC_MT_711 15 3 13 str_lo 15:28:49 1 Acoustic input: Nera ITC_MPO_2cc 15 3 13 str_lo 15:27: Nera ITC_FOG_2cc 15 3 13 str_lo 15:25: Nera ITC_MT_2cc 15 3 13 str_lo 15:28:19 All measurements are made on instruments with ProWax and O-Cap protection. directional mode is used unless Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. 1 Acoustic input: Nera_Ria_ITE_MPO 711 3 9 13 kbn_tjn 13:33:27 Nera_Ria_ITE FOG_711 4 9 13 kbn_tjn 14:8: Nera_Ria_ITE_MT_711 3 9 13 kbn_tjn 13:36:32 1 Acoustic input: Nera_Ria_ITE _MPO_2cc 3 9 13 kbn_tjn 13:34:15 Nera_Ria_ITE FOG_2cc 3 9 13 kbn_tjn 13:21:47 Nera_Ria_ITE _MT 2cc 3 9 13 kbn_tjn 13:37:16 OSPL Telecoil output () (Input ) ma/m field Hz Hz 1 121 123 115 121 116 64 54 56 47 54 49 48-71 Hz -69 Hz 85-5 - - 93/93 3. % 2. % 23 19 34 29 OSPL Telecoil output () (Input ) ma/m field SPLITS L / R Hz Hz 135 127 135 127 1 123 71 62 67 59 65 58 48-29 Hz -6896 Hz 95-115 - - 5/5 2. % <2 % 17 15 27 26.9 ma.9 ma.9 ma.9 ma Size: 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 118-13-11) 1/2 // MHz: 26/55/41 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: Custom instruments may be built with a reduced maximum gain to optimize size and performance for the individual. Size: 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 118-13-11) 155/2 // MHz: 15/45/28 * Based on the standardized battery consumption measurement (IIC 118-.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: Custom instruments may be built with a reduced maximum gain to optimize size and performance for the individual. 18 19

People First People First is our promise to empower people to communicate freely, interact naturally and participate actively 1385US / 12.13 Printed on % recycled paper www.oticonusa.com