Guide to ecodesign requirements for computers and computer servers. Are you a manufacturer or importer of computers and/or computer servers?

Similar documents
Guide to ecodesign requirement for networked products and household coffee machines

COMMISSION REGULATION (EU)

Notebook Computer (including Slates and Tablets) Hewlett Packard Company 3000 Hanover Street Palo Alto, CA United States of America

Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013

Annex 2. Working Document on Ecodesign Requirements for Computers and for Servers

Nordsyn ecodesign and energy labelling requirements for hot water storage tanks

ENERGY STAR Program Requirements for Computers. Version 5.0. Table of Contents

INFO. Legally binding regulations on relating to energy efficiency and environmental protection. Eco-Design Directive and EC-Commission Regulation

ENERGY STAR Qualification Activity: Version 5 (through January 2011)

Table of Contents Purpose of the guidelines and disclaimer... 3 Introduction... 4 Scope of the amended Regulation (EC) No 1275/

White Paper Energy Consumption ESPRIMO E5731 E85+

How To Use Softxpand (A Thin Client) On A Pc Or Laptop Or Mac Or Macbook Or Ipad (For A Powerbook)

Code of Conduct on Energy Efficiency of External Power Supplies

Desktop Virtualization Technologies and Implementation

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

OJ L 191, , p. 26. OJ L 2, , p. 1.

The Danish Energy Agency will carry out inspections in October We will check the CE marking of the smoke alarms you sell or use.

Emerging IT and Energy Star PC Specification Version 4.0: Opportunities and Risks. ITI/EPA Energy Star Workshop June 21, 2005 Donna Sadowy, AMD

Using GIGABYTE Notebook for the First Time

TheraDoc v4.6.1 Hardware and Software Requirements

Medical 360 Network Edition and Citrix

PLATO Learning Environment System and Configuration Requirements for workstations. October 27th, 2008

System Requirements - filesmart

Datasheet. The cost-optimized all-rounder

The hassle-free high-volume colour laser printer

Lecture 2: Computer Hardware and Ports.

Priority Pro v17: Hardware and Supporting Systems

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

Powerline 1200 User Manual

31 Jan, 2014, (EU) No 65/2014 and (EU) No 66/2014 were published on Official Journal of the European Union and entered into force on 20 Feb

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

newenergylabel.eu The new European energy label: the success story continues

Intel Management Engine BIOS Extension (Intel MEBX) User s Guide

CONSUMER INTERESTS IN ECO-DESIGN OF COMPLEX SET TOP BOXES

ENERGY STAR Program Requirements for Computer Servers DRAFT 4

PLATO Learning Environment 2.0 System and Configuration Requirements. Dec 1, 2009

Re: Notice of Proposed Determination of Computer Servers as a Covered Consumer Product, Docket # EERE-2013-BT-DET-0034

VMWARE WHITE PAPER 1

Understanding Task Scheduler FIGURE Task Scheduler. The error reporting screen.

About Parallels Desktop 7 for Mac

White Paper A Case Study Comparing Data Access Methods Using Remote Graphics Software and Siemens PLM Software, Teamcenter 2007 and NX 5

Intertek Testing Services 70 Codman Hill Road Boxborough, MA WORLD LAB

Axis Technologies Computer Hardware and Electronics Portfolio Categories

1. Desktop Systems: Given below is the clarification and suggested changes.

Recording. Smart recording (depending on the camera models)

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

DISCUSSION PAPER ECODESIGN FOR ENERGY RELATED PRODUCTS INTEGRATED INTO OTHER ENERGY RELATED PRODUCTS

Capabilities Statement

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

1000-Channel IP System Architecture for DSS

LogMeIn Network Console Version 8 Getting Started Guide

Energy Consumption of New Generation Game Consoles - Key Findings

UNDERSTANDING BATTERY LIFE IN PORTABLE COMPUTERS. Gary Verdun, Technology Strategist, Office of the Chief Technology Officer

2009 Ing. Punzenberger COPA-DATA GmbH. All rights reserved.

AXIS Camera Station Quick Installation Guide

System Environment Specifications Network, PC, Peripheral & Server Requirements

Web:

Using AORUS Notebook for the First Time

Dell Client Energy Savings Calculator. General description of energy consumption in computer systems:

2 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The standard system is shipped without HDD. 2. For the HDD compatibility list, please

Dell Wyse Cloud Connect

1 PERSONAL COMPUTERS

The Desktop Sharing Handbook. Brad Hards

Compliance Response Edition 07/2009. SIMATIC WinCC V7.0 Compliance Response Electronic Records / Electronic Signatures. simatic wincc DOKUMENTATION

BlackHawk for MAC Software User Guide

Data Sheet FUJITSU Thin Client FUTRO A300

System Requirements and Prerequisites

Seagate NAS OS 4 Reviewers Guide: NAS / NAS Pro / Business Storage Rackmounts

PLATO Learning Environment System and Configuration Requirements. for workstations. April 14, 2008

Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build

VS-4112U-RP Pro+ Hardware Spec.

SAP Business One Hardware Requirements Guide

USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p

Priority Zoom v17: Hardware and Supporting Systems

Dragon NaturallySpeaking and citrix. A White Paper from Nuance Communications March 2009

Pano Device. Data Sheet. How It Works: Key Benefits:

REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL. on the voluntary ecodesign scheme for games consoles

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

Data Sheet Fujitsu FUTRO A300 Thin Client

Remote Desktop solutions. CAS genesisworld with Remote Desktop solutions

Installer guide. Release 2.2

lesson 1 An Overview of the Computer System

Scout 1U Rackmount Computer

Systemverwaltung 2009 AIX / LPAR

Install Guide for JunosV Wireless LAN Controller

Cisco 7816-I5 Media Convergence Server

Thin Client & Virtual Desktop White Paper

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

ATV310B User Manual. V1.1

CONSUMER INTERESTS IN ECO-DESIGN OF GAME CONSOLES

Setting Up Control Rooms With Modern IT Solutions

Specifications for the Gateway M1300 Tablet PC

Android Box SNNPB73B

Cisco UCS B-Series M2 Blade Servers

Seagate Business Storage 8-bay Rackmount NAS Reviewer s Guide

Getting Started. Version 3.1 Last updated 2014/3/10. Orbweb ME: Getting Started

LDCDP GdW. L force Controls. Ä.GdWä. Software Manual. Industrial PC. WindowsR CE Thin Client. Operating system

ImproMed Hardware/Software Specifications

REVIEW STUDY ON COMMISSION REGULATION (EC) NO. 278/2009 EXTERNAL POWER SUPPLIES

2014 Teradici Corporation.

Transcription:

Guide to ecodesign requirements for computers and computer servers Contents Overview 1 Which products must comply with the requirements? 3 What are the requirements? 4 What are requirements for documentation? 9 Where can I find information? 10 Are you a manufacturer or importer of computers and/or computer servers? Please be aware. There are requirements for power management and energy efficiency Computers and computer servers must meet ecodesign requirements. This means that the products must be designed to provide power management and meet requirements for energy efficiency and maximum allowed energy consumption. Which products? The requirements apply to computers (including desktops, notebooks, tablets etc.), thin clients, workstations, small-scale servers and computer servers. When? The ecodesign requirements are introduced in three steps from respectively 17 th July 2013, 1 st July 2014 and 1 st January 2016. For desktop computers and notebooks the requirements include: Maximum allowed power consumption in lowest power states (from 17 th July 2013) Provision of low power state (from 17 th July 2013) Power management (from 17 th July 2013, and tightened from 1 st July 2014) Maximum allowed annual total energy consumption (from the 1 st July 2014, and tightened from 1 st January 2016) Maximum allowed sleep and off mode energy consumption (from 1 st July 2014) Provision of sleep mode or similar condition (from 1 st July 2014) Efficiency of internal power supply (from 1 st July 2014) Product information requirements (from 1 st July 2014) For computer servers, desktop thin clients, workstations, and small-scale servers the requirements include: Efficiency of internal power supply (from 1 st July 2014) Product information requirements (from 1 st July 2014) 1

Who? You have the responsibility of ensuring and documenting compliance with the requirements, if you are: a manufacturer in the EEA that produces electrical and electronic household and office equipment etc. to be placed on the market in the EEA an importer of electrical and electronic household and office equipment etc. from a country outside of EEA to be placed on the market in the EEA an authorised representative in the EEA for a manufacturer that is situated in a country outside of EEA The above mentioned responsible parties are hereafter referred to as suppliers. The EEA (European Economic Area) includes the EU member states and the EFTA counties. Why? Computers and computer servers account for a large share of the energy consumption in European households and offices. In 2020 the saving potential is estimated to be approximately 12.5 to 16.3 TWh. Consequently, EU has decided to establish ecodesign requirements for these products. Where can I find more information? Find relevant regulations on the last page of this guide, or read more about ecodesign and energy labelling on www.ens.dk/energikrav Disclaimer This guide presents the contents of the Regulation and is addressed to manufacturers, importers and others interested. The guide is not a substitution for the Regulation, in any case of doubt, the Regulation is applicable. This guide is not legally binding as a binding interpretation can only be made by the EU court. Acknowledgement This guide is financed by the Norwegian Water Resource and Energy Directorate (NVE). 2

Which products must comply with the requirements? The requirements apply to computers and servers, which can be powered directly from the mains alternating current including via an external or internal power supply. Table 1 shows products which are covered by the requirements and to avoid doubt, products that are exempted. Table 1 Products covered and exempted from the requirements The requirements apply to: Desktop computers Integrated desktop computers Notebook computers, including tablet computers, slate computers and mobile thin clients Desktop thin clients Workstations Mobile workstation Small-scale servers Computer servers The requirements do NOT apply to: Blade system and components Server appliances Multi-node servers Computer servers with more than four processor sockets Game consoles Docking stations Notebook computers with idle state power demand less than 6 W Desktop computers and integrated desktop computers are hereafter referred to as desktop computers. Definitions of covered products: Please see more detailed definitions in Article 1 of Regulation 617/2013/EU Desktop computer: Computer designed for use with an external display, keyboard and mouse, and not designed for portability. Integrated desktop computer: Computer where the display and computer itself function as one single unit either physically or via a power cord, and not designed for portability. Notebook computer: Computer designed for portability and operating in extended periods without direct connection to AC power source. Desktop thin clients: Computer that relies on a connection to remote computing resources to obtain primary functionality and has no integrated rotational storage. Workstation: High-performance, single-user computer primarily used for graphics, CAD, financial and scientific applications among other compute intensive tasks. Mobile workstation: Workstation which is designed specifically for portability and to be operated for extended periods of time either with or without a direct connection to an AC power source. Mobile workstations have integrated display and are capable of operation on an integrated battery. Small-scale server: Computer that typically uses desktop computer components (stored within one box) but is designed primarily to be a storage host for other computers and to perform functions such as providing network infrastructure services and hosting data/ media. Computer server: Computer designed to support computer server operating systems (OS) and/or hypervisors, and targeted to run user-installed enterprise applications. It is placed on the market with one or more AC-DC power supplies. 3

What are the requirements? From 17 th July 2013 desktop computers and notebooks are covered by ecodesign requirements. Additional requirements apply from 1 st July 2014, and 1 st July 2016. For other products than desktop computers and notebooks mentioned in table 1 ecodesign requirements apply from 1 st July 2014, and additional requirement from 1 st July 2016. The requirements include maximum allowed annual total energy consumption, maximum allowed sleep mode power consumption, lowest power state and off mode power consumption, internal power supply efficiency, provision of power management as well as product information requirements. From 17 th July 2013 Low power states and power management The requirements for desktop computers and notebooks include: Power consumption in the lowest power state 0.50 W (1.0 W in case of information or status display) Provision of a power state or mode, which power consumption does not exceed the above mentioned limit Provision of power management that automatically, when the computer is not providing a main function, switches the computer into a power mode that has a lower power that the applicable power demand for sleep mode Please be aware of requirements for power management enabling mentioned below. From 1 st July 2014 Annual total energy consumption (E TEC ) From 1 st July 2014 desktop computers and notebooks must comply with requirements regarding maximum allowed annual total energy consumption (E TEC ). The requirements are tightened from 1 st July 2016. Annual total energy consumption (E TEC in kwh/year) is calculated using power consumption in off, sleep and idle mode, and hours in a year the computer spend in that mode. The usage profile varies between the types of computers. E TEC is determined using the following formula: ( ) For computers that lack a sleep mode, but have idle state power demand less or equal to 10 W, the formula is replaced by: ( ) The allowed E TEC is higher for the desktop computers than for notebooks. It also depends highly on the category of the computer (A to D) and additional functionalities. Please see definitions of computer categories in table 2, requirements for desktop computers in table 3 and requirements for notebooks en table 4. 4

Table 2 Definitions of computer categories Type Category A Desktop computers A desktop computer that does not meet the definition of category B, C or D desktop computers. Category B A desktop computer with 2 physical cores within the CPU and a minimum of 2 GB of system memory. Category C A desktop computer with 3 or more physical cores within the CPU and either a minimum of 2 GB of system memory or a discrete graphics card, or both. Category D A desktop computer with 4 or more physical cores within the CPU, and either a minimum of 4 GB system memory or a discrete graphics card in the category G3 (with frame buffer data width > 128 bit), G4, G5, G6, or G7, or both. Integrated desktop computers An integrated desktop computer that does not meet the definition of category B, C or D integrated desktop computers. An integrated desktop computer with 2 physical cores within CPU and a minimum of 2 GB of system memory. An integrated desktop computer with 3 or more physical cores within the CPU and either a minimum of 2 GB of system memory or a discrete graphics card, or both. An integrated desktop computer with a minimum of 4 physical cores in the CPU, and either a minimum of 4 GB system memory or a discrete graphics card in the category G3 (with frame buffer data width > 128 bit), G4, G5, G6, or G7, or both. Notebook computers A notebook computer that does not meet the definition of category B, or C notebook computers. A note book computer with at least one discrete graphics card. A notebook computer with at least the following: A minimum of 2 physical cores in the CPU, a minimum of 2 GB of system memory, and a discrete graphics card in the category G3 (with frame buffer data width > 128 bit), G4, G5, G6 or G7. Discrete graphic cards categories: G1: Frame buffer bandwidth 16 G2: 16 < Frame buffer bandwidth 32 G3: 32 < Frame buffer bandwidth 64 G4: 64 < Frame buffer bandwidth 96 G5: 96 < Frame buffer bandwidth 128 G6: Frame buffer bandwidth > 128 (with frame buffer data width < 192) G7: Frame buffer bandwidth > 128 (with frame buffer data width 192) 5

Table 3 Maximum annual total energy consumption for desktop computers Category E TEC kwh/year From 1 st July 2014 From 1 st July 2016 Category A 133 94 Category B 158 112 Category C 188 134 Category D 211 150 Additional allowances Additional allowances for extra memory, internal storage, discrete tuner and audio cards, and discrete graphics cards. The allowance for graphic cards depends on its category*. *Note: See the full list of additional allowances in Annex II of Regulation 617/2013/EU Table 4 Maximum annual total energy consumption for notebooks Category E TEC kwh/year From 1 st July 2014 From 1 st July 2016 Category A 36 27 Category B 48 36 Category C 80.5 60.5 *Note: See the full list of additional allowances in Annex II of Regulation 617/2013/EU Additional allowances Additional allowances for extra memory, internal storage, discrete tuner and audio cards, and discrete graphics cards. The allowance for graphic cards depends on its category*. Sleep and off modes requirements From 1 st July 2014 requirements regarding maximum allowed power consumption in sleep and off mode apply to desktop computers and notebooks. Furthermore desktop computers and notebooks must provide sleep mode or a similar condition, which power consumption does not exceed the maximum allowed value for sleep mode. Desktop computers are allowed a higher consumption in sleep mode than notebooks. For computers with enabled WOL (Wake On Lan) functionality in sleep mode or off mode an additional allowance of 0.7 W can be applied. Please see the requirements in table 5. Table 5 Maximum allowed power consumption for sleep and off mode from 1 st July 2014 Computer type Sleep mode* Off mode* Desktop computer Notebook Extra allowance for enabled WOL functionality 5.00 W 3.00 W 1.00 W + 0.7 W + 0.7 W 6

Internal power supply efficiency From 1 st July 2014 desktop computers, desktop thin clients, workstations, small-scale servers, and computer servers must comply with requirements concerning internal power supply efficiency and power factor (PF). The requirements depend on the type of power supply and for single output AC-DC power supplies for computer servers of the rated input. Please see the requirements in table 6. Table 6 Requirements for efficiency of internal power supply and power factor (PF) from 1 st July 2014 Product groups At 10 % of rated output At 20 % of rated output At 50 % of rated output At 100 % of rated output Desktop computers, desktop thin client, workstation and small-scale server* All internal power supplies Computer server - Efficiency 82 % Efficiency 85 % Efficiency 82 % PF = 0.9* All multi output AC-DC power supplies - Efficiency 82 % PF 0.8 Efficiency 85 % PF 0.9 Efficiency 82 % PF 0.95 Single output AC-DC rated input 500 W Efficiency 70 % Efficiency 82 % PF 0.8 Efficiency 89 % PF 0.9 Efficiency 85 % PF 0.95 Single output AC-DC 500 < rated input 1000 W Efficiency 75 % PF 0.65 Efficiency 85 % PF 0.8 Efficiency 89 % PF 0.9 Efficiency 85 % PF 0.95 Single output AC-DC rated input > 1000 W Efficiency 80 % PF 0.8 Efficiency 88 % PF 0.9 Efficiency 92 % PF 0.9 Efficiency 88 % PF 0.95 *Internal power supplies for desktop computer, integrated desktop computer, desktop thin client, workstation and small-scale server with a maximum rated output power of less than 75 W are exempt from the power factor requirement. Power management enabling From the 1 st July 2014 a set of more specific requirement for power management apply to desktop computer, integrated desktop computer and notebooks. The requirements include: Reduction of the speed of any active 1 Gigabit per second (Gb/s) Ethernet network links when transitioning to sleep or off-with-wol mode Wake up time from sleep mode to the system becoming fully usable should happen with a latency of maximum 5 seconds Display sleep mode set to activate within 10 minutes of user inactivity (as default) Ability to enable and disable WOL functions for sleep mode and off-mode (if WOL function is available and supported) Sleep mode or another condition that provides sleep mode functionality should activate within 30 minutes of user inactivity (as default). Possibility for the users to easily activate and deactivate any wireless network connections and provision of a clear indication with a symbol, light or equivalent, when wireless network connections have been activated or deactivated Please see more details in Regulation 617/2013/EU Annex II point 6. 7

Product information From 1 st July 2014 product information must be shown on a freely accessible website of the manufacturer. The website must among others include information about: Power consumption in various modes E TEC value and capability adjustment applied when all discrete graphic card are enabled and disabled* Internal power supply efficiency Noise levels Minimum number of loading cycles for battery** Description of various sequence and steps with regard to power management* Length of time before display sleep mode is set to activate* Duration of idle state before the computer automatically reaches sleep mode* Length of time before the computer automatically reaches a power mode with lower consumption than sleep mode* User information about energy saving potential of power management and on how to enable power management* For products with display containing mercury the content of mercury as x,x mg* Information about test parameters and measurement methodology *The requirement does not apply to workstations, desktop thin clients, small-scale servers and computer servers. **The requirement does only apply to notebooks. If a product model is placed on the market in multiple configurations the product information required should be reported once per product category, for the highest power-demanding configuration available within the category. Furthermore a list of all model configurations should be provided. More details appear from Regulation 617/2013/EU Annex II point 7. Additionally for notebooks If a notebook computer is operated by batteries that cannot be accessed and replaced by a nonprofessional user, the manufacturer s website and the packaging of the notebook must include the following information: The battery(ies) in this product cannot be easily replaced by users themselves. The information provided on the packaging must be clearly visible and legible and be provided in all the official languages of the country where the product is marketed. 8

What are the requirements for documentation? CE marking and EC declaration of conformity Products covered by ecodesign requirements must be CE marked when they are placed on the EEA market. Furthermore an EC declaration of conformity must be available by the suppliers. In the EC declaration of conformity, the manufacturer or its authorised representative in the EEA must document and guarantee that their products fulfil all relevant EU regulations, i.e. the following reference numbers of Ecodesign Regulations should be mentioned: (EU) No 617/2013 for computers and computer servers (EC) No 278/2009 for external power supplies Find requirement for the contents of EC declaration of conformity in the Ecodesign Directive 2009/125/EC Annex VI. Technical documentation The supplier is responsible for making sure the product has a technical documentation when placing it on the EEA market. The technical documentation should show that the product is constructed in conformity with the requirements in all relevant ecodesign regulations. The technical documentation must be compiled by the manufacturer. For computers and computer servers, you can see the requirement for technical documentation in Regulation (EU) No 617/2013 Annex II point 7. The information in the technical documentation is similar to the information that must be provided on the website of the manufacturer. The market surveillance authorities of EEA countries may request the technical documentation, and you must provide it within a maximum of ten days after receiving the request. The documentation must be stored for ten years after the last examples of the model are produced. Measurement and calculation methods The power consumption of computers and computer servers must be measured by a reliable, accurate and reproducible measurement procedure, which takes into account the generally recognised state of the art. A reproducible measurement procedure means that the measurement can be repeated and produce the same results. Measurements must always be carried out in accordance with guidelines of the Regulation. 9

Where can I find information? Danish Energy Agency s homepage www.ens.dk/energikrav contains more information about policies, new requirements in regulations, guidance, contact information and links to relevant legislation. Legislations Commission Regulation (EU) No 617/2013 with regard to ecodesign requirements for computers and computer servers: http://eur-lex.europa.eu/lexuriserv/lexuriserv.do?uri=oj:l:2013:175:0013:0033:en:pdf Directive 2009/125/EC of the European parliament and of the council establishing a framework for the setting of ecodesign requirements for energy-related products: http://eur-lex.europa.eu/lexuriserv/lexuriserv.do?uri=oj:l:2009:285:0010:0035:en:pdf Danish legislations with regard to ecodesign The ecodesign directive is implemented by the following Danish legislations: Lovbekendtgørelse om miljøvenligt design af energirelaterede produkter, nr. 1068 af 15. september 2010 Bekendtgørelse om miljøvenligt design af energirelaterede produkter, nr. 1274 af 19. november 2010 (only available in Danish) Where can I find help and guidance? You can have your questions answered and help to comply with the requirements by contacting the Secretariat for Ecodesign and Energy Labelling of Products Telephone: +45 43 30 50 20 Monday to Thursday 9:00 16:00 Friday 9:00 15:30 E-mail: sekretariat@eco energimaerke.dk Danish Energy Agency Amaliegade 44 DK 1256 Copenhagen K www.ens.dk Telephone: +45 33 92 67 00 E-mail: ens@ens.dk More about ecodesign and energy labelling: www.ens.dk/energikrav E-mail: ecodesign@ens.dk 10