MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter



Similar documents
Thermal Mass Flow Meter (Series MST)

Thermatel Model TA1 Mass Flow Transmitter

Immersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon

FCI ST75 Series Flow Meters

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

For Multi-Parameter Meters see mvx

Typical Aluminum GFM Mass Flow Meter

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

The Unique Accelabar Flow Meter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electronic Flow Switches

Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.

Laminar Flow Elements

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

How To Use A Ds340 (Dsp)

Sanitary Type Electronic Flow Switches

COMBIMASS. Technical Data COMBIMASS eco-bio +

Turbine Flowmeters for Gas Applications

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

QuadraTherm 640i/780i HIGH ACCURACY : FOUR-SENSOR : MASS FLOW METER

How To Use A Flowmeter

In-Line Electronic Flow Switches

Regulator Options and Accessories

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

Model 111 Mass Flow Instruments

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TELEDYNE HASTINGS INSTRUMENTS

Centro-Matic Automatic Lubrication Systems System Controls

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Mass Flow Meters & Controllers

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

T U R B I N E G A S M E T E R

Electromagnetic Flow Meter

Analytical Instruments Smart Analyzer 90 Type SMA

IMVIB. Online vibration monitoring for Ariel compressors

Thermal Mass Flow Meters

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Gas Mass Flow Control Products

Digital inductive conductivity transmitter

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

User s Manual Laminar Flow Elements

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

S300 Series Dust Monitors

Heating Cable. Construction

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Thermal Dispersion Mass Flow

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

F-5100 Inline Thermal Mass Flow Meter Installation and Operation Guide

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Plastic tube flowmeters Series PT/PS

API Marine. BMS Presentation. Ballast Measurement Systems

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

AYSIX-SAGE GAS MASS FLOW METERS FOR INDUSTRY

Duct Humidity Transmitter

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

SITRANS F flowmeters SITRANS F M

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Toroidal Conductivity Sensor

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

Micro Motion Model D and DL Coriolis Flow and Density Meters

Liquid Level Limit Switch liquiphant T FTL 20

O C M III. Open Channel Flow Monitor

The L&J Engineering Model MCG 1500SFI Servo Gauge

4 Posiflow Proportional Solenoid Valves

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

Open channel & partially filled pipe Ultrasonic flow meters

OEM-EP Pressure Controllers

Heating, air-conditioning, cooling

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

PIEZOMETER AIRFLOW MEASURING RING

Instruction Manual. T3111 T3111L T3111P T3111Ex

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Models SFP33 & SFP32 Pressure Transmitters

PRODUCT REVIEW. Flowmeters and Controllers. Vacuum Instrumentation

Micro Motion 3098 Gas Specific Gravity Meter

OPTIMASS 6000 Technical Datasheet

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

SAGE GAS MASS FLOW METERS

Electronic Control Devices The European Product Catalogue 2007

Mobrey Hydrastep and Hydratect

Buckeye Detection Systems Fixed Detection Systems Application Survey

Pressure Switch for gas and air

Transcription:

Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases using constant temperature differential sensing for fast response and low flow accuracy. Constant temperature differential is achieved by changing the power to the sensor. The amount of power applied to the sensor is proportional to the mass flow rate of the gas being measured. The MTI10/MTL10 is virtually immune to changes in temperature and pressure over a wide range of flow. The unique Cal-V feature allows for in-situ testing of the meter s accuracy by testing the functionality of the sensor and the processing circuitry. MTI10_MTL10 View software allows the user to adjust the meter configuration, monitor alarm conditions, log data and view data from your PC. The MTI10_MTL10 View software connects the flowmeter to a PC using an USB mini connection. The MTI10/MTL10 electronics are ideal in environments where high vibration or dirty power may affect meter performance. The transmitter provides a wide range of user outputs including two 4-20mA, pulse or alarm, and Modbus RTU. Feature Calibrated in actual gas Higher power than competitor sensors Temperature differential sensing Cal-V MTI10_MTL10 View Immune to changes in temperature and pressure Benefit Better accuracy, surrogate gases are not always linear across entire flow range Faster response time, wider turndown Better low flow accuracy In-situ validation of sensor and circuitry, no need to return meter to factory Ability to log data, adjust meter configuration and monitor alarm conditions from a PC Delivers repeatable, accurate flow measurement under varying flows Performance Specifications Specification Product Performance Accuracy MTL10 In-line MTI10 Insertion ±1.0% of rate ±0.2% full scale ±1.0% of rate ±0.4% full scale Repeatability MTI10/MTL10 ±0.2% full scale Straight run requirements MTL10 In-line MTI10 Insertion 8 diameters upstream, 4 diameters down 15 diameters upstream, 10 diameters down response time MTI10/MTL10 0.9 seconds Temperature accuracy Standard sensor High temp sensor ±1.0 C (±1.8 F) ±2.0 C (±3.6 F) Calibration MTI10/MTL10 NIST standards using actual application gas 216 Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification.

Thermal Mass meter and Temperature Transmitter Operating Specifications Fluid Type Dry and clean gas or air Line Size MTL10 in-line: 8mm to 150mm (0.25 to 6 ) MTI10 insertion: 40mm (1.5 ) and larger Process Temperature Limit Standard sensor: -40 to 121 C (-40 to 250 F) High temperature sensor: 0 to 343 C (32 to 650 F) Process Pressure MTI10 insertion Compression fitting: 34.5 bar (500 psig) Retractor assembly : 8.6 bar (125 psig) High pressure retractor (with crank) NPT: 41.4 bar (600 psig) ANSI Class 150 and 300; No valve supplied MTL10 in-line NPT: 34.5 bar (500 psig) ANSI Class 150: 16 bar (230 psig) Note: Pressure ratings stated for temperatures of 38 C (100 F) Input Power DC: 22-26VDC, 24VDC nominal, 0.75 amp. standard AC: 85 to 264VAC, 47-63Hz, 20 watts optional Ambient Relative Humidity 0 to 90% RH, non-condensing Ambient Temperature Limit DC power: -40 to 70 C (-40 to 158 F) AC power: -20 to 70 C (-4 to 158 F) Remote sensor box: -40 to 100 C (-40 to 212 F) Cable Conduit connection ANSI 3/4 NPT M20 x 1.5mm (optional) Signal cable 5 conductor, 18 AWG, twisted, shielded. Maximum length 100 feet. range 15 to 60,000 SFPM (0.07 to 280 NMPS) Turndown: up to 1,000:1; typical 100:1 Typical Range for MTI10 Insertion Nominal Size SCFM NM³/hr 40mm (1.5 ) 0-840 0-1,320 50mm (2.0 ) 0-1,400 0-2,200 80mm (3.0 ) 0-3,080 0-4,860 100mm (4.0 ) 0-5,300 0-8,360 150mm (6.0 ) 0-12,000 0-18,900 200mm (8.0 ) 0-20,800 0-32,800 300mm (12.0 ) 0-46,600 0-73,500 Full Scale Range for MTL10 In-line Nominal Size SCFM NM³/hr 8 (0.25) 0-20 0-32 15 (0.50) 0-90 0-140 20 (0.75) 0-180 0-280 25 (1.00) 0-320 0-500 32 (1.25) 0-580 0-910 40 (1.50) 0-840 0-1,320 50 (2.00) 0-1,400 0-2,200 65 (2.50) 0-2,000 0-3,150 80 (3.00) 0-3,080 0-4,860 100 (4.00) 0-5,300 0-8,360 150 (6.00) 0-12,000 0-18,900 Note: Standard conditions of air at 70 F and one atmosphere. Consult Spirax Sarco for other gases and flow ranges. Outputs Analog Two isolated 4-20mA output (one for flow rate, second programmable for flow rate or temperature); fault indication per NAMUR NE43 Pulse Isolated pulse output 0 100HZ, 5 24 volts p/p for flow. 10 amps max. Communications USB - Connect to PC using MTI10_MTL10 View software provides configuration capability, remote process monitoring, and data logging. Modbus RTU RS 485 Physical Specifications Sensor Material 316 stainless steel, Hastelloy C276 (optional) Probe 316 stainless steel Compression Fitting 316 stainless steel Enclosure NEMA 4X (IP68), aluminum Agency Approvals CE Approved - MTI10, 24 VDC power only FM and FMc: Approved Class I, Div. 1, Groups B, C, D; Class II, Div.1, Groups E, F, G; Class III, Div. 1; T3C 217

Thermal Mass meter and Temperature Transmitter Dimensions MTI10 Insertion with retractor, local and remote 6.5 (165.1) 3.9 (99.1) (205.7) 3.9 (99.1) (205.7) REMOTE CABLE, 5 CONDUCTOR, SHIELDED, 100ft (30.48m) MAX CONDUIT, 3/4, METAL ø3.6 (ø91.4) 4.4 (111.8) 2.0 (50.8) 2X 3/4 NPT, FEMALE 5.9 (149.9) 2X 3/4 NPT, FEMALE (205.7) 3.9 (99.1) LL 6.5 (165.1) 10.3±0.3 (261.6±7.6) Fig. 1 2X 3/4 NPT, FEMALE 3.9 (99.1) LL (205.7) 10.3±0.3 (261.6±7.6) REMOTE CABLE, 5 CONDUCTOR, SHIELDED, 100ft (30.48m) MAX CONDUIT, 3/4, METAL 0.87 (22.1) LL 10.3±0.3 (261.6±7.6) 2X 3/4 NPT, FEMALE 0.87 (22.1) Fig. 2 0.87 (22.1) MTI10 Insertion Meter With Retractor Probe Size Probe Size Dimension LL ±.01 Model Code mm (inches) mm (inches) 375R 375 (15) 375 (15) 450R 450 (18) 450 (18) 600R 600 (24) 600 (24) 750R 750 (30) 750 (30) 900R 900 (36) 900 (36) 218

Thermal Mass meter and Temperature Transmitter MTI10 Insertion with stainless steel probe, local and remote 4.3 (109.2) (205.7) Input Power 2x 3/4 inch NPT Female Signal Wiring Fig. 3 HH LL L C 3.6 (91.4) 4.4 (111.8) 2.0 (50.8) Input Power 2x 3/4 inch NPT Female Remote Cable, 5 Conductor, Shielded, 100ft (30.48m) Max. 4.5 HH LL MTI10 Insertion Meter Probe Size Probe Size Dimension LL ±.01 Dimension HH ±.01 L C Model Code mm (inches) mm (inches) mm (inches) 150I 150 (6) 150 (6) 315 (12.5) 225I 225 (9) 225 (9) 390 (15.5) 300I 300 (12) 300 (12) 470 (18.5) 375I 375 (15) 375 (15) 550 (21.5) 450I 450 (18) 450 (18) 620 (24.5) Fig. 4 600I 600 (24) 600 (24) 770 (30.5) 750I 750 (30) 750 (30) 930 (36.5) 900I 900 (36) 900 (36) 1080 (42.5) 219

Thermal Mass meter and Temperature Transmitter MTL10 In-line with NPT connections, local and remote 3.6 (91.4) 4.4 (111.8) 2.0 (50.8) Input Power 2.0 Remote Cable, 5 Conductor, Shielded, 100FT Max. HH 2x NPT Male Thread 4.3 (109.2) (205.7) LC Input Power 2x 3/4 inch NPT Female H Signal Wiring L Fig. 6 2x NPT Male Thread LC L Fig. 5 In-line Meter With NPT Connections Body Size Body Size Dimension L Dimension H Model Code mm (inches) mm (inches) mm (inches) 8 8 (0.25) 145 (5.8) 265 (10.5) 15 15 (0.50) 300 (12) 265 (10.5) 20 20 (0.75) 300 (12) 265 (10.5) 25 25 (1.00) 300 (12) 265 (10.5) 32 32 (1.25) 300 (12) 265 (10.5) 40 40 (1.50) 300 (12) 265 (10.5) 50 50 (2.00) 300 (12) 265 (10.5) 65 65 (2.50) 450 (18) 270 (10.6) 80 80 (3.00) 450 (18) 270 (10.6) 100 100 (4.00) 450 (18) 280 (11.1) 220

Thermal Mass meter and Temperature Transmitter MTL10 In-line with ANSI 150# RF flange connections, local and remote 3.6 (91.4) 4.4 (111.8) 2.0 (50.8) 2X 3/4 " NPT, Female Remote Cable, 5 Conductor, Shielded, 100FT Max. 4.5 HH (205.7) C L 4.3 (109.2) H 2x 3/4 inch NPT Female L Fig.8 LC L 2X Flange, Raised Face, ANSI B16.5, 316 SST Fig. 7 In-line Meter With Flange Connections Body Size Body Size Dimension L Dimension H Model Code mm (inches) mm (inches) mm (inches) 15 15 (0.50) 300 (12) 265 (10.5) 20 20 (0.75) 300 (12) 265 (10.5) 25 25 (1.00) 300 (12) 265 (10.5) 32 32 (1.25) 300 (12) 265 (10.5) 40 40 (1.50) 300 (12) 265 (10.5) 50 50 (2.00) 300 (12) 265 (10.5) 65 65 (2.50) 450 (18) 270 (10.6) 80 80 (3.00) 450 (18) 270 (10.6) 100 100 (4.00) 450 (18) 280 (11.1) 150 150 (6.00) 600 (24) 310 (12.2) 221

Thermal Mass meter and Temperature Transmitter Ordering Information MTI10 Insertion Category Description Suffix Code Model Mass Thermal Insertion & Temperature Transmitter MTI10 Probe 150mm (6 ) Sensor 150I 300mm (12 ) Sensor 300I 375mm (15 ) Sensor 375I 450mm (18 ) Sensor 450I 600mm (24 ) Sensor 600I 750mm (30 ) Sensor 750I 900mm (36 ) Sensor 900I 375mm (15 ) Sensor, 125 psig retractor with 3/4 NPT full port valve 375R 450mm (18 ) Sensor, 125 psig retractor with 3/4 NPT full port valve 450R 600mm (24 ) Sensor, 125 psig retractor with 3/4 NPT full port valve 600R 750mm (30 ) Sensor, 125 psig retractor with 3/4 NPT full port valve 750R 900mm (36 ) Sensor, 125 psig retractor with 3/4 NPT full port valve 900R Sensor Material 316 SS wetted parts: temperature sens\or, probe, compression fitting SS Hastelloy C-276 sensor & probe, 316 SS compression fitting SH Hastelloy C-276 sensor & probe, Monel compression fitting SJ Hastelloy C-276 sensor & probe, Hastelloy C-276 compression fitting SL Temperature Standard Transmitter Type -40 to 120 C (-40 to 250 F) ST High Temperature 0 to 343 C (32 to 650 F) 1 HT Enclosure Local Enclosure, NEMA 4X, 24 VDC E1 Local Enclosure, NEMA 4X, 85 to 250 VAC E2 Remote sensor J-box, 24 VDC, 100 ft max cable, order separately, requires option E3 board 2 Remote sensor J-box, 85 to 250 VAC, 100 ft max cable, order separately, requires option E4 board 2 Display 7 Rate/Total Display & Configuration Panel DD Option Boards Blank Option Board 3 B0 Isolated 24VDC power & terminal block for remote sensor 4 B1 Modbus RS485, Isolated 24VDC power & terminal block for remote sensor 4 B2 222

Thermal Mass meter and Temperature Transmitter Calibration 5, 6 Air, Nitrogen, mass flow < than 2040 NM3M (1200 SCFM) G1 Air, Nitrogen, mass flow > than 2040 NM3M (1200 SCFM) G2 Argon, Carbon Dioxide, Hydrogen, Natural Gas, Oxygen mass flow < 1700 NM3M G3 (1000 SCFM) Argon, Carbon Dioxide, Hydrogen, Natural Gas, Oxygen mass flow > 1700 NM3M G4 (1000 SCFM) Carbon Monoxide, Helium, Ammonia, Propane <1190 NM3M (700 SCFM) G5 Carbon Monoxide, Helium, Ammonia, Propane >1190 NM3M (700 SCFM) G6 Biogas, Digester Gas, Flare Gas, Flash Gas, Vent Gas, and all other gases G7 Example MTI10 100I SS ST E1 DD B2 G3 1 Remote electronics recommended for all high temperature applications. 2 Cable not included, it must be ordered separately. 3 Do not select when ordering remote sensor 4 Option boards needed for power, communications, and remote display options. 5 Calibration prices are for new flowmeters only. Contact SSI for recalibration prices. 6 Above 4,250 NM3M (2,500 SCFM) contact SSI for calibration charge. 7 Use Display Configuration Code to specify the display orientation based on the flow direction. Note: Insertion meters can be installed on pipes 40mm (1.5 ) and larger. Use the inline meters for pipes smaller than 40mm (1.5 ). Calculating probe length (probe needs to be installed in the middle of the pipe): Insertion length = 1/2 the pipe diameter + 80mm (3 ) + insulation + retractor (codes 15R through 36R use 250mm (10 )). Round up to the next largest probe. 223

Thermal Mass meter and Temperature Transmitter MTL10 In-line Line size, pipe material/connection matrix Standard ASME Rating NPT 150 Line size Material SST CS SST CS 8mm (0.25 ) Avail 15mm (0.5 ) Avail Avail 20mm (0.75 ) Avail Avail 25mm (1.0 ) Avail Avail 32mm (1.25 ) Avail Avail 40mm (1.5 ) Avail Avail 50mm (2.0 ) Avail Avail Avail Avail 65mm (2.5 ) Avail Avail Avail Avail 80mm (3.0 ) Avail Avail Avail Avail 100mm (4.0 ) Avail Avail 150mm (6.0 ) Avail MTL10 In-line Model Code Category Description Suffix Code Model 7 Mass Thermal Inline & Temperature Transmitter MTL10 Line Size 8mm (0.25 ) 008 15mm (0.5 ) 015 20mm (0.75 ) 020 25mm (1.0 ) 025 32mm (1.25 ) 032 40mm (1.5 ) 040 50mm (2.0 ) 050 65mm (2.5 ) 065 80mm (3.0 ) 080 100mm (4.0 ) 100 150mm (6.0 ) 150 Connection NPT Male 1NB ASME 150 3AB Tube 316 SS 6C A106B Grade B Carbon steel 4D Sensor Material 316 SS wetted parts: temperature sens\or, probe, compression fitting Hastelloy C-276 sensor & probe, 316 SS compression fitting Temperature Standard Transmitter Type -40 to 120 C (-40 to 250 F) High Temperature 0 to 343 C (32 to 650 F)¹ Enclosure Local Enclosure, NEMA 4X, 24 VDC Local Enclosure, NEMA 4X, 85 to 250 VAC Remote sensor J-box, 24 VDC, 100 ft max cable, order separately, requires option board² Remote sensor J-box, 85 to 250 VAC, 100 ft max cable, order separately, requires option board² SS SH ST HT E1 E2 E3 E4 224

Thermal Mass meter and Temperature Transmitter Display 8 Rate/Total Display & Configuration Panel DD Option Boards Blank Option Board 3 B0 Isolated 24VDC power & terminal block for remote sensor 4 B1 Modbus RS485, Isolated 24VDC power & terminal block for remote B2 sensor4 Calibration 5, 6 Air, Nitrogen, mass flow < than 2040 NM3M (1200 SCFM) G1 Air, Nitrogen, mass flow > than 2040 NM3M (1200 SCFM) G2 Argon, Carbon Dioxide, Hydrogen, Natural Gas, Oxygen mass flow G3 < 1700 NM3M (1000 SCFM) Argon, Carbon Dioxide, Hydrogen, Natural Gas, Oxygen mass flow G4 > 1700 NM3M (1000 SCFM) Carbon Monoxide, Helium, Ammonia, Propane <1190 NM3M G5 (700 SCFM) Carbon Monoxide, Helium, Ammonia, Propane >1190 NM3M G6 (700 SCFM) Biogas, Digester Gas, Flare Gas, Flash Gas, Vent Gas, and all other G7 gases Example MTL10 008 1NB 6C SS ST E1 DD B1 G1 1 Remote electronics recommended for all high temperature applications. 2 Cable not included, it must be ordered separately. 3 Do not select when ordering remote sensor 4 Option boards needed for power, communications, and remote display options. 5 Calibration prices are for new flowmeters only. Contact SSI for recalibration prices. 6 Above 4,250 NM3M (2,500 SCFM) contact SSI for calibration charge. 7 MTL10 does not have CE approval 8 Use Display Configuration Code to specify the display orientation based on the flow direction. Accessories Part Number Description 100657 Stainless Steel Tags EM000677 Chamber of Commerce Certificate of Origin 101570 5 conductor, 18 AWG PVC shielded cable for remote, specify feet (100' maximum) SCA00010 Remoted Enclosure Mounting Kit 890000 meter cleaned and bagged for Oxygen service 102878 Teflon Ferrule Kit (MTI10 only) 225

MTI10 Insertion and MTL10 In-line Thermal Mass meter and Temperature Transmitter Display Configuration Codes (D1) Display Position (D2) Display Position (D3) Display Position (D4) Display Position (D5) Display Position (D6) Display Position DISPLAY DISPLAY (D7) Display Position (D8) Display Position 226