Technical Bulletin. Fountain Solutions, ph and Conductivity



Similar documents
Water, ph and Conductivity for printers

ph and CONDUCTIVITY ph and conductivity in fountain solution are necessary for plate humidification.

Fountain Solution in Offset Printing INK ACADEMY

Wastewater Reuse. Typical treated wastewater is:

The Relationship between ph and Deionized Water

Paper interaction with fountain solution during multi-color offset printing

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

Some 24 years ago, U.S. printers

The Basics of Fertilizer Calculations for Greenhouse Crops Joyce G. Latimer, Extension Specialist, Greenhouse Crops; Virginia Tech

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

Removing Heavy Metals from Wastewater

Corrosion Inhibitors in Antifreeze Coolants

Understanding ph management and plant nutrition Part 5: Choosing the best fertilizer

Chemistry Slide 1 of 50

This value, called the ionic product of water, Kw, is related to the equilibrium constant of water

Chem101: General Chemistry Lecture 9 Acids and Bases

Neutralizing an Acid and a Base

CHM 130LL: ph, Buffers, and Indicators

Acid Base Titrations

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

Nickel Free Room Temperature Seal: an innovative and ecological process

ph. Weak acids. A. Introduction

Acids, Bases, and ph

Pure Water. Isn t Hard to Find

WATER CHEMISTRY AND POOL WATER BALANCE

ph: Measurement and Uses

Chemistry 122 Mines, Spring 2014

Ion Exchange Softening

MAINTAINING YOUR SPA WATER

Question Bank Electrolysis

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

Equilibria Involving Acids & Bases

A PRIMER ON ph. A Presentation for ASTA Conference September 30-October 1, 2008

Chemistry 201. Practical aspects of buffers. NC State University. Lecture 15

Coating and Extraction of Honeycomb Denuders

Note: (H 3 O + = hydronium ion = H + = proton) Example: HS - + H 2 O H 3 O + + S 2-

RBS detergents for laboratories

Trusted Brands - Perfect Synergy Products for Heatset Web Printers

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

Inferred ph in Steam Plant Water Chemistry Monitoring

Separation of Amino Acids by Paper Chromatography

Of Cabbages and Kings

Laboratory Glassware Cleaning

Chemical equilibria Buffer solutions

Adhesive Bonding of Natural Stone

Offset Printing Technology Questions and Answer

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

WATER-SOLUBLE METALWORKING FLUIDS

FIVE SIMPLE STEPS TO BREWING GREAT COFFEE

Chapter 3 Student Reading

5s Solubility & Conductivity

Saturated NaCl solution rubber tubing (2) Glass adaptor (2) thermometer adaptor heating mantle

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

6.8 Measuring the Acidity of Solutions Page 160

Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that

The Chemical Adjustment Reference Cheat Sheet

ph Measurements of Common Substances

EXPERIMENT 20: Determination of ph of Common Substances

Chemists use the ph value to measure how acidic or basic a solution is. The ph scale runs from 0 to 14:

ENE 806, Project Report 3 CHEMICAL PRECIPITATION: WATER SOFTENING. Grégoire Seyrig Wenqian Shan

Titrations. Acid-Base Indicators and Titration Curves. Shapes of Titration Curves. A titration curve is a graphical history of a titration

Acids and Bases. AND a widemouth container of the following solids:

CHEMICAL PRECIPITATION: WATER SOFTENING

Q.1 Classify the following according to Lewis theory and Brønsted-Lowry theory.

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Irrigation Water Quality for Greenhouse Production

Describing Acids and Bases

Jet Press 720. B2 sheet-fed inkjet digital press

Introducing an All New Line of Cleaning Chemicals

4.2 Bias, Standards and Standardization

IMPORTANT: Spa Owner, save this manual. Installer, leave this manual with the spa owner.

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Review and apply Investigation 5. Let s review Pages

List the 3 main types of subatomic particles and indicate the mass and electrical charge of each.

Chemical Calculations: The Mole Concept and Chemical Formulas. AW Atomic weight (mass of the atom of an element) was determined by relative weights.

Profiles for floors of same height Cerfix Projoint

Estimation of Hardness of Water by EDTA Method

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

Company Profile p.3. Product Coding System p.4. Saturated carboxylated polyesters for TGIC systems

3 The Preparation of Buffers at Desired ph

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Chapter 9 Lecture Notes: Acids, Bases and Equilibrium

AMR and GMR Heads Increase Hard Drive Capacity in Western Digital Drives

3.4 BRØNSTED LOWRY ACIDS AND BASES

SNEAK PEAK inside ACTIVITY. ADVANCE PREPARATION see next page for more details Dilute alcohol with water Set out plastic cups, etc.

Test Bank - Chapter 3 Multiple Choice

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Metal Rescue Rust Remover Technical Data

Acids & Bases Around the House Use a ph indicator to find acids and bases

Hot Tub Start-up Guide

Dissolved Mineral Radioactivity in Drinking Water

Use of Carbon Nanoparticles for the Flexible Circuits Industry

More inside :: Tackle even the toughest water treatment piping challenges with

DRUG TESTING The Analysis of Some Over-the-Counter Drugs 2004 by David A. Katz. All rights reserved.

Transcription:

Issue 2005 1 Technical Bulletin Fountain Solutions, and Conductivity BCKGROUND People with only a passing familiarity with the offset printing process have probably heard the phrase, ink and water, often in the context of a pressroom problem. When Senefelder discovered the lithographic process in 1798, he found that the secret of keeping ink in the image area of the printing plate, or in his day the lithographic stone, was to have a thin film of water in those areas where ink was not wanted. The presence of a very thin film of water in these so-called non-image areas was sufficient to prevent ink from being transferred to the plate from the inking rollers. How we create image and non-image areas is not the purpose of this bulletin. Rather we want to discuss the water used in the process, for it is not pure water but a dilute chemical solution that makes the process work as well as it does. The chemical solution, usually called the dampening or fountain solution, or fount in Europe, historically was a dilute solution containing phosphoric acid and gum arabic. In fact, it was Senefelder who discovered the benefits of the components and to this day very few, if any, superior replacements have been found in spite of all the changes and improvements made in the lithographic process itself. FOUNTIN SOLUTION COMPOSITION Modern fountain solutions generally consist of a concentrated solution of chemicals that are diluted, in the pressroom, to the working concentration. Typically, we might add one to six ounces of concentrate to a gallon of water. The extent of the dilution varies depending on the actual concentration of the chemicals in the concentrated solution. While we most often encounter acid-based fountain solutions, there are also neutral and alkaline-based solutions used in certain industry segments, specifically the non-heat web offset markets such as newspaper printing. Our discussion here will concentrate on the acid systems. Table 1 shows the typical acid fountain solution composition. Phosphoric acid has always had a unique role in fountain solution chemistry, but it has also been cited as a possible cause of catalyst poisoning in the afterburners of web offset press ovens. For that reason, alternatives such as citric acid are used. What keeps the non-image area water receptive is the presence of a chemical known as a desensitizer gum arabic has proven to be the best over time. It works best in an acidic environment, hence the reason for having the phosphoric, or other acid present. Buffering agents are materials that help keep the acidity, as measured by the of the solution, at a fixed value, regardless of its concentration. We ll come to this important concept in just a moment. Corrosion inhibitors are necessary because the dampening solution can be very aggressive toward metal parts on the press and supporting equipment. Likewise, bactericides are necessary in order to prevent unwanted bacterial and algae growth in the dampening system. This is especially critical in solutions that are neutral or alkaline in. The wetting agent is a rather recent addition to the mix. t one time, it was found necessary to add

Technical Bulletin alcohol, typically isopropyl alcohol (isopropanol), to the diluted solution such that the resultant mix contained anywhere from 5%-25% alcohol. The purpose in doing this was to improve the ability of the solution to wet out the dampening rollers and nonimage areas of the printing plates. Because of insurance concerns (the alcohol is very flammable), alcohol is rarely used in North merica, at least at the high concentrations formerly used. Other chemicals, known as wetting agents, are now used and may be present either in the fountain solution concentrate itself, or added to the diluted solution at press-side. Some wetting agents have been known to create foam problems in the circulation system, hence defoamers might also be found in the fountain solution concentrate. In many pressrooms, all the dilutions and additions generally take place automatically. Figure 1 depicts the process. The amount of concentrate to use (typically between 1 6 ounces/gallon) is determined by the composition of the fountain solution. When alcohol was being used it was always added separately because so much was required that it could not be packed into the fountain solution concentrate. Since there were two additions or steps required, this was called a Two Step fountain solution. When alcohol substitutes or replacements were introduced, it was often found that lesser amounts were needed, and it was possible to squeeze it into the concentrate itself. These solutions became known as One Step solutions. Everything was in one container, which simplified the mixing equipment, but more of the concentrate was required. One Step or Two, it doesn t matter. What is important, and is often overlooked, is that the concentration of all the active ingredients must be maintained at the proper level. Overdosing, particularly with a One Step solution, to correct one problem, will likely create additional problems because the other components will then be present at elevated concentrations. We mentioned earlier that the main desensitizing agent, gum arabic, is most effective at maintaining acidic values. What is? To a chemist, is the negative logarithm of the hydrogen ion Table 1. Typical components in an acid fountain solution cid Desensitizer Buffering agents Corrosion inhibitors Bactericides Wetting agents Defoamers - the basis for most fountain solutions and one that provides the best environment for the desensitizer (often gum arabic) to work; often phosphoric acid but others, such as citric, are also used - to keep the non-image area water receptive (gum arabic is still the desensitizer of choice) - to help stabilize the of the solution - to prevent corrosion of metal components on the press - to prevent the growth of bacteria and algae in the dampening system - to help the solution wet the non-image area of the plate - to minimize/eliminate foam in the circulating system 2

Glatfelter 2005 Figure 1. utomatic fountain solution mix Concentrate 1 oz. 6 oz./gallon " " " lcohol or alcohol substitute Fresh water supply Press-ready solution To Press # concentration. To the non-chemist, however, it is an indicator of how acidic a solution is. Figure 2 shows how the scale works. Water contains positively charged hydrogen ions (H + ) and negatively charged hydroxyl ions (OH - ). Ions are simply atoms or molecules that are electrically charged. When the = 7, there is an equal number of each, and we say that the water has a neutral. However, if there are more hydrogen ions than hydroxyl ions, H + > OH -, then the water is considered acidic (if OH - > H +, then the water is alkaline). The greater the ratio, the more acidic (or alkaline) the water. Note that on the scale a solution with = 4 is 10 times more acidic (it has 10x the concentration of hydrogen ions) than a solution with = 5, and so on, thus the logarithmic function in the definition. Figure 3 shows how the of a hypothetical fountain solution would change as its concentration is increased. In the graphic arts, it is customary to refer to the concentration in terms of ounces of concentrate per gallon of diluted solution (ounces/ gallon). The region where gum arabic is most effective is around = 4 4.5. By increasing the Figure 2. Concentration, in moles/liter of hydrogen and hydroxyl ions, and their relationship to Concentration and OH - H + 0.1 0.000000001 ~0 14 7 1 ~0 0.000000001 0.1 3

Technical Bulletin Figure 3. Differences between regular and buffered fountain solutions Buffered Unbuffered Concentration, ounces/gallon concentration we not only increase the gum arabic concentration, we also cause the to decrease, perhaps to an excessively low level. s the becomes too low, we can dissolve carbonate in the paper s coating. This is where the concept of buffered solutions comes into play. By adjusting the chemistry of the solution, it is possible to ensure that the of the solution stays fairly constant, regardless of the concentration of the fountain solution concentrate. This effect is also depicted in Figure 3. Buffering agents keep the constant, in spite of contamination by materials from both the ink and paper that would alter the of an unbuffered solution. lthough buffered fountain solutions offered the advantage of a controlled, they created a new problem. Historically, a pressman would check the of the solution and, by knowing the could be fairly confident that the proper numbers of ounces per gallon of etch (also known as fountain solution concentrate) were present. With buffered solutions, was no longer a reliable measure of concentration. To overcome this, an alternative methodology was sought, and in 1976, the use of conductivity measurements was introduced 1. Conductivity refers to the electrical conductivity (the opposite of electrical resistance) of the solution. Solutions that contain dissolved ions conduct electricity the more ions the higher the conductivity. These ions come not only from the hydrogen ions, but other materials present in the fountain solution. Figure 4 depicts the general relationship between etch concentration, and electrical conductivity. s can be seen, the change in conductivity with etch concentration is linear, thus making it an ideal tool for checking the concentration of etch. The of the 4

Glatfelter 2005 Figure 4. Typical changes in and conductivity for an acid etch Figure 5. Typical changes in / conductivity with concentration, two different solutions Conductivity, Solution and B Conductivity, Solution Conductivity, Solution B Conductivity Conductivity Concentration, ounces/gallon Concentration, ounces/gallon solution is still important, however, and needs to be checked as well. Fountain solution manufacturers have many materials at their disposal when it comes to formulating their products. Each of these components may contribute to the overall electrical conductivity of the solution in its own way, thus it is important to remember that the conductivity of the solution is only important insofar as it relates to the concentration of the etch. There is no magic value for conductivity as there is for. s shown in Figure 5, it is quite possible to formulate two fountain solutions having similar -concentration characteristics but different conductivity-concentration curves. Understanding how all the pieces fit together will make clear why both the and the conductivity of the fountain solution are important. 1 Bates, J. B., and Blom, B. E., ccurately monitoring concentration of alkaline fountain solutions, Newspaper Production, 5(7), 20-25 (1976). 5

Technical Bulletin Frequently sked uestions 1. Is it true they still use alcohol (isopropyl alcohol) at fairly high levels in European pressrooms? The answer is yes but this is changing. Environmental, health and safety regulations forced North merican pressrooms to find alternatives to alcohol many years ago. Europe has been slow in adopting these changes primarily because the use of alcohol in the fountain solution was extremely helpful, and the regulatory climate did not discourage its use. gain, this is changing. 2. I ve been told to make sure the conductivity of my etch stays between 1500 2000. Is this correct? No. s explained earlier, there is no magic value for the conductivity reading. Different etches, being used at their proper levels, can give different conductivity readings. The conductivity reading is only to be used to ensure that the proper concentration of etch is present. In order to do this, you need to have a calibration curve, showing the conductivity versus concentration, prepared for each etch and dilution water combination. The is still important, however. 3. What happens if the of the fountain solution is too low? In the case of sheetfed printing inks that undergo a chemical reaction as they dry, an excessively low (< 3.5) can interfere with the chemical reaction and prevent ink drying. Below = 4, calcium carbonate, used in many of our paper coatings, can dissolve. The problem is aggravated as the gets lower and can be worsened by certain fountain solution components. 4. If calcium carbonate were dissolved into the fountain solution, would the begin to rise? Yes, if the fountain solution were not buffered. On the other hand, if the fountain solution were buffered, the calcium carbonate contamination would not increase the of the solution unless the absorption capacity of the buffer were reached. s discussed earlier, the buffering agent serves to keep the fairly constant in the presence of contaminants. 5. I haven t heard that there are any problems in Europe, where they have been running high carbonate coating for many years. Why is this? European fountain solutions tend to run around = 5, as opposed to North merican fountain solutions which run closer to, and sometimes below, = 4. Why the difference? Most often cited is the use of alcohol in European pressrooms, but this explanation is not universally agreed upon. For example, hard water is often found in Europe and even recommended by some authorities. The same concentration of etch in hard water will have a higher than in deionized water. 6

Glatfelter 2005 Frequently sked uestions (continued) 6. You mentioned there were other fountain solutions that were not acidic. Can you tell me more about them? In the late 1960s, early 1970s, it was discovered that alkaline fountain solutions, similar in chemical composition to detergents, worked well in nonheat web operations, primarily newspapers. They were much more cost-effective than conventional acidic solutions and had the added benefit that the printing plates did not need to be wiped with a gum arabic solution during press shutdowns. They were used much like their acid counterparts. Evolutions in their formulation also allowed them to be sold in dry form. The user could add the dry form to a predetermined amount of water and in super concentrate form, dilute 10 gallons to make 55 gallons of the standard concentrate. These latter versions afforded appreciable freight savings to the user. neutral solutions also appeared and enjoyed limited success in the newspaper production industry. The popularity of neutral solutions grew so that today they are extensively used in newspaper production whereas alkaline solution usage has diminished. However, there appears to be renewed interest in alkaline solutions because of their resistance to bacteria growth compared to their neutral counterparts. 7. Does it matter what the and conductivity of the water is that I m using to make my pressready fountain solution? Yes and no. Conductivity readings are pretty much additive. For example, suppose a particular fountain solution, mixed at the ratio of one ounce per gallon with deionized water, which has a conductivity of zero, gives a reading of 2,000. If the same dilution had taken place with water that itself had a conductivity reading of 500, then this solution would read 2,500 on our meter. Thus, when making a calibration curve (conductivity versus ounces/gallon), be sure to read the conductivity of the diluting water. Water quality, and potentially conductivity readings, can change during the course of the year, depending on local water supply systems. Be sure to check the conductivity/ of the water periodically to ensure that the calibration curve remains accurate. The of the diluting water is usually not too important. If it is between = 6 to 8, then the chemistry of the fountain solution tends to overwhelm and dominate the properties of the solution. However, it is good practice to measure the and conductivity of the solution when preparing the calibration curve, just in case. 7

Technical Bulletin Frequently sked uestions (continued) 8. Should I be using tap water or treated water to mix my fountain solution? Not surprisingly, it depends. The water chemistry of most urban water systems is sufficiently stable that it can be used as is. Other areas of the country experience fluctuations, sometimes daily, often seasonally, in water quality, and this could upset the chemistry of the fountain solution and perhaps the ink-water balance on press. Keep in mind that these variations in water chemistry can also have an impact on plate processing. 9. If I need to treat my water, what method should I use? softener, a deionizer, or a reverse osmosis unit? softener removes the hardness minerals, calcium and magnesium, from the water and replaces them with common salt. This is considered only a partial solution to water problems and is not generally recommended or found in the majority of press/plate rooms. Deionizers and reverse osmosis units remove all minerals, but the reverse osmosis (RO) units have the advantage of removing some organic contaminants as well. Maintenance of RO units is generally simpler although their initial cost is often higher than deionizers. RO appears to be the method of choice in most plate/press rooms. For more information, contact: Glatfelter 353 South Paint Street Chillicothe, Ohio 45601 TFS_Carbonless@glatfelter.com Technical Bulletin Issue 2005-1 First published May 2002. Revised February 2004. Glatfelter 2005 NP034 Rev. 05/05 8