University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008



Similar documents
DATA CENTRE DESIGN AND

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Your partner of choice for integrated energy solutions

Fact Sheet on China s energy sector and Danish solutions

Annual Electricity and Heat Questionnaire

Sustainable Data Centre

Metrics for Data Centre Efficiency

WHITE PAPER. How To Build A Real Green Data Centre. Contents. Part 1: Drivers for Data Centre energy efficiency. February 2008

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

How To Evaluate Cogeneration

COFELY DISTRICT ENERGY DELIVERING LOW CARBON SUSTAINABLE ENERGY SOLUTIONS

ICT and the Green Data Centre

Personal Power Stations: The Australian Market for Micro-Combined Heat and Power to 2021

Half the cost Half the carbon

ABSTRACT DCMCCT PROJECT OVERVIEW

World s Greenest High Performance Data Center

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Low Carbon Data Centres without compromise

CHP Strategies and Options / Stored Energy ENERGY SYMPOSIUM April8, 2014 Reading Country Club

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Energy from digester gas. Optimised biogas utilisation

UNDERSTANDING ENERGY BILLS & TARRIFS

VISIT 2010 Fujitsu Forum Europe 0

New business segments for the energy saving industry Energy efficiency and decentralised energy systems in the building & housing sector

Top Technology for Industry, Agriculture, Business and Communities

HEATING, VENTILATION & AIR CONDITIONING

PEAK DISTRICT NATIONAL PARK AUTHORITY ENVIRONMENTAL MANAGEMENT ANNUAL PERFORMANCE REPORT 2013/2014

Green Development of Infrastructure and Campus: Modern Practice and Approach in District Heating and Cooling System

Siemens turbine solutions for urban cogeneration

Our financing of the energy sector in 2013

Micro cogeneration. Affordable, efficient and innovative

ENERGY SAVINGS ACTION PLAN

Carbon Management Plan

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Eco Server Park The Responsible Power Ready Location

THE NEXT GREEN THING. How Teliti International will help clean up our information and shape the future of green data centres in Malaysia

Best Practice Guide BPGCS007

Energy Distribution: District Heating and Cooling - DHC M6_ ENERGY DISTRIBUTION: DISTRICT HEATING AND COOLING

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.

Good Practice Form

Table of Contents. 2 Why IT Organizations Everywhere Need to go Green. 3 Greening the Data Center

Combined Heat & Power. Discussion with Connecticut Energy Advisory Board. February 23, 2010

Capgemini UK Infrastructure Outsourcing

Big Buildings lead to big savings

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

Open Data Center Alliance - Sustain andustain

DC Pro Assessment Tools. November 14, 2010

Energy Efficiency Opportunities Report Continuing our sustainability journey

CENIC 2009 Conference

Further electricity cost increases with the introduction of the Carbon Pollution Reduction Scheme

ALWAYS ON GLOBALSWITCH.COM

Cool Carpet - Clean Up the Emissions Around Us

Energy saving technology to deliver the fastest returns. Top 10 energy saving options

CITY OF SYDNEY DECENTRALISED ENERGY MASTER PLAN RENEWABLE ENERGY DECEMBER 2013

Energy Management Strategy

Generating Current Electricity: Complete the following summary table for each way that electrical energy is generated. Pros:

Efficiency Metrics for CHP Systems: Total System and Effective Electric Efficiencies

Preparatory Paper on Focal Areas to Support a Sustainable Energy System in the Electricity Sector

Columbia University Master Planning & Optimization

Analysis of data centre cooling energy efficiency

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

CHP - The Business Case

Green Data Centers. Jay Taylor Director Global Standards, Codes and Environment (512)

NEW JERSEY CENTER OF EXCELLENCE

Combined Heat and Power Central Area

Renewable Energy LORD Green Real Estate Strategies, Inc.

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Applicability of Trigeneration Systems in the Hotel Buildings: The North Cyprus Case

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Saving Energy For Your Organisation. Top 10 energy saving tips

UTILITIES AND ENERGY MANAGEMENT

Stationary Energy Storage Solutions 3. Stationary Energy Storage Solutions

Growing your greenhouse business faster with gas engines.

Category 3: Fuel- and Energy-Related Activities Not Included in Scope 1 or Scope 2

3 ENERGY USE IN THE HEALTHCARE INDUSTRY

Strategies for Local Sustainable Economic Development

The solution for your business

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

Building Energy Systems. - HVAC: Heating, Distribution -

ELECTRICAL ENERGY REDUCTION IN REFRIGERATION AND AIR CONDITIONING Ken Landymore, Director of Operations, Smartcool Systems Inc.

ENERGY MANAGEMENT. for INDUSTRY AND BUSINESS

GAS HEATING IN COMMERCIAL PREMISES

GERMAN ENERGY TRANSITION: BEST PRACTICES IN SECURING A RELIABLE AND EFFICIENT ENERGY SUPPLY AND SEIZING NEW MARKET OPPORTUNITIES

Office of the Government Chief Information Officer. Green Data Centre Practices

EVALUATION OF GEOTHERMAL ENERGY AS HEAT SOURCE OF DISTRICT HEATING SYSTEMS IN TIANJIN, CHINA

Benefits of Geothermal Energy By Dr. Silas Simiyu

From today s systems to the future renewable energy systems. Iva Ridjan US-DK summer school AAU Copenhagen 17 August 2015

Living Green in the Data Center. Dominick Regina Associate Director, Infrastructure Services

RECOVERING RESOURCES FOR ALL. Integra South East Energy Recovery Facility

Princeton University Microgrid

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

Sustainable Performance for Data Centres. DCEM-Plus

Energy Saving by ESCO (Energy Service Company) Project in Hospital

Controlling Micro-CHP Generators as a Virtual Power Plant

Transcription:

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study Conclusions Questions

Introduction

Galileo Connect is a data centre product, development and services company providing mission critical solutions to multinational corporations and system integrators on a global basis. Technical Real Estate is a property development and investment company based in Asia Pacific.

Galileo Connect Asia Pacific projects CTC (Canberra Technology City) Canberra, Australia 14,000 m 2 data halls Norwest Sydney, Australia 3,000 m 2 data halls Pioneer Park Jurong, Singapore 22,800 m 2 data halls Tokyo Tokyo, Japan 4,000 m 2 data halls

Chapter 1: Data Centre Energy Recap

ICT Industry The worldwide ICT industry contributed 2% to global CO 2 emissions in 2007 (830 Mt CO 2 -e per annum 1 ) Data centres are represent a significant portion of the ICT industry Global demand for data centres continues to rise year-on-year Data centre sustainability challenges Significant exposure to energy price changes Carbon footprint reduction Location considerations (water consumption, flora, fauna, etc.) International green benchmarking Centralisation vs Decentralisation Emissions Trading Source 1. Smart2020: Enabling the low carbon economy in the information age, The Climate Group, 2008

Current industry metrics PUE (Power Usage Effectiveness) is an industry accepted ratio for the measurement of the effective usage of electrical power in a data centre. It is represented by the quotient: PUE = Total Facility Power IT Equipment Power The reciprocal of PUE expressed as a percentage is known as the Data Centre infrastructure Efficiency DCiE and is represented by the quotient: DCiE = 1 PUE x 100 %

Where does the energy go? Operational energy model of a data centre over 15 years Component IT equipment Cooling & ventilation Power system losses (UPS, transformers, etc) Utility T&D losses to site Misc (lighting, BMS, security, etc) Total Energy consumed 197 GWh 177.4 GWh 26.3 GWh 32.7 GWh 11.2 GWh 444.6 GWh Percentage 44.3% 39.9% 5.9% 7.3% 2.5% Basis of energy model: 1000 m 2 data hall @ 1500 W/m 2 Tier 3 PUE = 2.1 (average) Excludes embodied energy

Data centre energy split (over 15 years)

Strategies for increasing data centre efficiency Cogeneration High efficiency cooling systems Use of outside air Raised floor pressure management High efficiency UPS systems Variable speed drives on pumps and fans High frequency lighting ballasts with T5 lamps Programmable lighting control and zoning Heat recovery systems on ventilation air Low energy transmission façade Reduced building leakage (infiltration rate) Sub-metering for all major equipment On-site renewable energy sources (limited potential) Green Power contracts

Carbon Footprint Electricity Sources Source: ActewAGL

New metric - CO 2 per kw of IT Example 1 Australian Grid Electricity, PUE 2.1 1kW of IT = 8.76 MWh p.a. Carbon footprint = IT Load x PUE x Energy source emission factor = 8.76 x 2.1 x 1.0 = 18.4 Tonnes CO 2 -e p.a. Example 2 Natural Gas Cogeneration, PUE 1.47 1kW of IT = 8.76 MWh p.a. Carbon footprint = IT Load x PUE x Energy source emission factor = 8.76 x 1.47 x 0.45 = 5.8 Tonnes CO 2 -e p.a. Notes: Operational CO 2 only, excludes embodied energy Demonstrates the importance of data centre facility efficiency and the source of energy

Chapter 2: Cogeneration

What is cogeneration? Cogeneration is the simultaneous production of electricity and heat from a single process (combustion of a fuel). Electricity generation (by fossil fuel combustion) is by nature a very inefficient process. Typical efficiency of 30-40%. Cogeneration systems capture the waste heat which would otherwise be discharged to atmosphere and put it to work. Typical use of captured heat energy: Hot water Steam Drying air Steam turbine (combined cycle power generation) Chilled water Cogeneration systems are not new. Industry has been utilising the technology for many years. District heating systems Industrial processes (brewery, minerals processing, glass manufacturing, etc) Hospitals Swimming pools

Traditional Cogeneration Source: SDA Engineering Coopers Brewery Adelaide

Cogeneration in data centres Cogeneration systems have traditionally been deployed in situations where there is simultaneous demand for power and heat. Cogeneration can be equally applied to situations where there is a requirement for simultaneous power and cooling (a.k.a. tri-generation) by deploying absorption chillers. This innovative use of cogeneration technology opens up opportunities for enormous CO 2 reduction

Combined Power and Cooling Explained Traditional Electricity Generation Fuel in (coal or gas) 100% Heat 65% Waste heat to atmosphere Gas 100% Gas Fired Co-generation Waste heat 15% Captured heat 50% Chilled Water Electricity 35% Electricity 35% Data Centre Data Centre Utilise waste heat from electricity generation to produce chilled water Traditional electricity generation: 1 Tonne CO 2 per MWh Co-generation: 0.45 Tonnes CO 2 per MWh

Combined Power and Cooling Details Extent of CCP Plant Heat rejection VCC Chillers C E Plate Heat Exchanger Hot Gas Heat Recovery Data Halls Sub station CHW from absorption chillers Hot Water Heat Recovery Gas Utility Electricity Supply HV electricity from CHP feed into Substation

Cogeneration benefits for data centres Environmental benefits Electricity generation on-site, hence eliminate T&D losses. Utilise a cleaner source of fuel (i.e. natural gas) Harness waste heat and provide 100% of data centre cooling requirements without electric chillers. Hence, significantly reduced PUE. Significant reduction in CO 2 emissions Economic benefits Significantly reduced PUE = significantly lower energy costs Protection against increasing electricity prices Protection against implications of ETS

Chapter 3: CTC Case Study

Canberra Technology City 14 x 1000 m 2 data halls, 1500kW IT capacity per hall Purpose built data centre campus PUE = 1.31 On-site gas fired cogeneration

Basic power and cooling demands Electrical demand Data centre PUE = 1.31 Total site electrical load = 28 MW-e Cooling demand Total site heat load = 33.6 MW-r

CTC Cogeneration Solution 3 x 14 MW-e gas turbines with double effect absorption chillers (N+1) as a central energy plant for the site. Primary source of power and chilled water from cogeneration plant Underground reticulation of HV and chilled water throughout the campus Backup power from 132kV electricity grid Backup cooling from air cooled packaged chillers (each building) No export capability (full power demand used on site) 65% carbon footprint reduction per kw of IT when compared to industry average data centres

Embodied Energy Embodied energy in the context of a data centre includes emissions and energy use associated with: Extraction of raw materials Manufacture of building elements and engineering equipment Manufacture of IT equipment Transportation of raw materials and assembled equipment Fuel and energy use during construction Construction waste disposal and wastewater treatment CTC embodied energy is approximately 49,000 tonnes CO 2 -e. 1 2.33 tco2-e per kw (peak) of IT capacity 3.5 tco2-e per m2 of data hall Over the 25 year lifetime of the development, the embodied energy equates to just over 1% of total carbon emissions Source 1. Canberra Technology City Environmental Impact Statement, GHD, November 2008

Conclusions

Conclusions Data centre energy costs are already significant, and are set to rise further. Data centre facility efficiency is equally as important as IT efficiency Data centres are a good match for cogeneration systems (constant electrical and cooling load) Cogeneration significantly reduces energy costs and CO 2 emissions by: Eliminating utility T&D losses Natural gas fuel source rather than coal electricity grid Cooling energy is provided free from absorption chillers Reduced PUE = reduced energy costs Items for further work: International efficiency rating system for data centres Metrics for measuring efficiency of ICT productivity (e.g. CO 2 per instruction) Comparison data for embodied energy in data centres

Questions / Contacts Asia Pacific Level 12 301 George Street Sydney NSW 2000 Tel: +61 (0) 2 9272 8888 Fax: +61 (0) 2 9272 8771 Questions.. Dan Pointon 0449 903 299 dpointon@technicalrealestate.com Websites www.galileoconnect.com www.technicalrealestate.com.au