N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes



Similar documents
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E5063A ENA Series Network Analyzer

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Make Better RMS Measurements with Your DMM

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent FieldFox Remote Viewer

Evaluating Oscilloscope Bandwidths for Your Application

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

N6171A MATLAB Data Analysis Software for Agilent Instruments

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent VEE Pro Data Sheet

DDR Memory Overview, Development Cycle, and Challenges

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Variable Frequency Drive Troubleshooting with U1610A/U1620A

The Next Generation in Automated Oscilloscope Test

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

802.11ac Power Measurement and Timing Analysis

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

PXI and AXIe Modular Instrumentation

Agilent U2000 Series USB Power Sensors

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes

Agilent U2000 Series USB Power Sensors

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

PXI and AXIe Modular Instrumentation

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Agilent 4339B/4349B High Resistance Meters

Agilent U2000 Series USB Power Sensors

Agilent 87421A/87422A Power Supply

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

Agilent Automotive Power Window Regulator Testing. Application Note

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Agilent Network Monitoring Content Intercept Manager

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Agilent 4338B Milliohm Meter

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

PCI Express 1.0 (2.5 GT/s) Protocol Test

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent U4301A PCI Express 3.0 Analyzer Module. Data Sheet. Agilent solutions for PCIe Gen1 to Gen3 analysis and emulation.

High-Speed Inter Connect (HSIC) Solution

LAN extensions for Instrumentation

Keysight N6854A Geolocation System. Configuration Guide

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Keysight E5063A ENA Series PCB Analyzer

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent Television Power Consumption Testing. Application Note

WD Hard Drive Interface Guide

Computer Specifications

APPLICATION NOTE. Easily Create Custom Waveform Plug-Ins With Waveform Creator Application Software

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

Building Hybrid Test Systems, Part 1

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent VEE Refine your design sooner. Change your work, change your world

Release Notes: PowerChute plus for Windows 95 and Windows 98

Agilent GPIB, USB and Instrument Control Products

TekSmartLab TBX3000A, TSL3000B Datasheet

1.5 GHz Active Probe TAP1500 Datasheet

Keysight Technologies Solutions for WLAN ac Manufacturing Test

The Real Total Cost of Ownership of Your Test Equipment

Updating the QIAcube operating software

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

USBSQ USB 2.0 Signal Quality Analysis Application. Electrical Testing Notes

Agilent Test Solutions for Multiport and Balanced Devices

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Agilent E6832A W-CDMA Calibration Application

Agilent Modular Products Connecting and Configuring JMR RAID to Work with the Agilent M9392A Vector Signal Analyzer System

Agilent OSS access7 Signaling Meter

Agilent P940xA/C Solid State PIN Diode Switches

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Cisco Secure Access Control Server Solution Engine

Agilent Model Quality Assurance (MQA) Industry Standard SPICE Model Signoff and Acceptance Software

NI USB-6008/6009 OEM USER GUIDE

CISCO PIX SECURITY APPLIANCE LICENSING

E5092A Configurable Multiport Test Set

Agilent IMS-SIP Network Emulator Software (E6966A)

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Universal Serial Bus Implementers Forum EHCI and xhci High-speed Electrical Test Tool Setup Instruction

Application Notes for VTech 1-Line and 2-Line Analog Hotel Phones with Avaya IP Office 8.1 and Voic Pro 8.1 Issue 1.0

COMPLIANCE 3 SOFTWARE SUITE

M24LRxx/CR95HF application software installation guide

Transcription:

N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical specification compliance for your USB.0 devices, hosts and hubs. The software executes the official USB-IF MATLAB scripts with MATLAB s runtime engine embedded in the oscilloscope. Easy-to-use interface for fast setup, configuration and automated test Recognized by the USB-IF for USB compliance testing Additional features: support for USB OTG (on-the-go) and multi-trial testing USB-IF MATLAB script execution inside the Infiniium oscilloscope Award-winning Infiniium ease of use Test fixtures for USB. (low- and full-speed), USB.0 (high-speed) and USB OTG compliance

Easily verify USB electrical parameters With USB compliance test software, you can take the Infiniium oscilloscope you use for everyday debugging and use it to verify USB electrical parameters with the same testing scripts the USB-IF created for official compliance testing at designated workshops. The USB compliance test software has a new setup wizard that allows you to quickly and easily test all facets of electrical compliance of your device, host or hub. The setup wizard menu structure of the N546A USB test option provides a level of simplicity not found with other vendors multi-tiered menu structures for executing tests and documenting results. Figure. The Infiniium USB compliance tests are incorporated directly into the oscilloscopeís menu structure as a submenu under the Analyze menu Figure. You can configure and launch the Infiniium USB compliance tests through a single window

Easily verify USB electrical parameters Low-, full- and high-speed tests require compliance with signal quality, inrush current, droop, drop, and backdrive voltage tests. Hi-speed USB requires compliance with an additional suite of tests. These tests are provided by the USB compliance test software, along with USB OTG (on-the-go) test capability (with the automated USB OTG electrical test fixture). Tests can be executed directly from the scope interface under the Analyze menu. Figure 3. You can select individual tests or the entire list of compliance tests from a single window page 3

Benefits In the past, pre-compliance testing in a lab environment involved capturing data with an oscilloscope, transferring it to a PC and post-processing it with a software program. Agilent has simplified the process by installing a run-time version of MATLAB software in the scope and integrating the USB test option into the Infiniium oscilloscope s menu structure. Once the test is executed, the test results appear on the Infiniium display in an HTML-formatted window. Figure 4. Test instructions and diagrams are included to help you configure your equipment Figure 5. Infiniium scopes automatically display test results in an html window immediately after test execution 4

Benefits Each test also automatically saves the PNG, HTML, and TSV files required by the USB-IF. The higher data rates associated with hi-speed USB.0 demand a measurement system that will not interfere with your device/ host/hub operation by loading the system. The award-winning InfiniiMax probing system, which is compatible with Infiniium oscilloscopes, provides unmatched signal fidelity ensuring your measurement system does not load the signals under test so it does not compromise the specification margins for passing the electrical signal quality tests. The InfiniiMax probing system has been approved by the USB-IF for compliance testing. The set of six high-speed test fixtures are highly manageable in a test environment due to their small size. The six fixtures allow you the flexibility to run different tests concurrently when you have more than one host, hub, or device to verify for compliance. The OTG fixture available is the only automated OTG test fixture for USB OTG compliance testing. Figure 6. The results are stored in a printable HTML report Figure 7. USB OTG test instructions 5

Extensibility You may add additional custom tests or steps to your application using the N5467A User-Defined Application (UDA) development tool (www.agilent.com/find/uda). Use UDA to develop functional Add-Ins that you can plug into your application. Add-ins may be designed as: Complete custom tests (with configuration variables and connection prompts) Any custom steps such as pre or post processing scripts, external instrument control and your own device control Figure 8. Importing a UDA Add-In into your test application Figure 9. UDA Add-In tests and utilities in your test application 6

Automation You can completely automate execution of your application s tests and Add-Ins from a separate PC using the included N545A Remote Interface feature (download free toolkit from www.agilent.com/find/scope-apps-sw). You can even create and execute automation scripts right inside the application using a convenient built-in client. The commands required for each task may be created using a command wizard or from remote hints accessible throughout the user interface. Using automation, you can accelerate complex testing scenarios and even automate manual tasks such as: Opening projects, executing tests and saving results Executing tests repeatedly while changing configurations Sending commands to external instruments Executing tests out of order Combine the power of built-in automation and extensibility to transform your application into a complete test suite executive: Interact with your device controller to place it into desired states or test modes before test execution. Configure additional instruments used in your test suite such as a pattern generator and probe switch matrix. Export data generated by your tests and post-process it using your favorite environment, such as MATLAB, Python, LabVIEW, C, C++, Visual Basic etc. Sequence or repeat the tests and Add-In custom steps execution in any order for complete test coverage of the test plan. Figure 0. Remote programming script in the Automation tab Figure. Combine the power of built-in automation and extensibility to transform your application into a complete test suite executive 7

Recommended Test Equipment The N546A USB test option requires an Infiniium 4-channel or 4+6 channel oscilloscope. To run hi-speed USB compliance tests, you will need E649A/E649B fixtures. For low/ full-speed tests, you will need a E646B SQuIDD test fixture. For USB OTG tests, in addition to the Infiniium oscilloscope, you will need an N547A USB OTG test fixture and an E363A power supply and 3440A digital multimeter. No fixtures are supplied with the N546A software. One SQuIDD test fixture must be ordered separately as part number E646B (for low- and fullspeed testing). A set of six high-speed test fixtures for signal quality, receiver sensitivity, TDR, and host disconnect must be ordered separately as part number E649B. For USB OTG (on-thego) test, USB OTG electrical fixture must be ordered separately as part number N547A. Figure. USB OTG test selections Figure 3. E649B test fixture 8

Recommended Test Equipment (continued) Recommended high-speed test equipment [] Infiniium Series oscilloscope (recommended bandwidth: GHz or higher) Model or part number Description Quantity N546A USB.0 low-/full-/high-speed test option for Infiniium oscilloscopes [] E649B Hi-speed USB.0 test fixture set consists of: E649-6640 Device TDR/signal quality test fixture E649-6640 Host TDR/signal quality test fixture E649-66403 Device receiver sensitivity fixture E649-66404 Host disconnect test fixture E649-66405 Droop and drop test fixture 3A/3A/34A InfiniiMax probe amplifier (qty required for hub testing) N544A InfiniiMax III 3.5mm to precision BNC adapter (required for the 90000 X-Series) 3 E678A Differential socketed probe head for InfiniiMax probe amplifiers (qty required for hub testing) Digital signal generator [3] 830A Pulse data generator with options: -MB SRAM memory card (UFJ) 83A 660-MHz option 8493C 006 6-dB attenuator Male SMA cable Or 834A pulse generator 5433B 500 ps transition time converter (for use with the 834A) Male SMA cable 8357B* USB-to-GPIB interface converter TDR [4] 8600A/B/C 54754A Male SMA cable 3440A Digital multimeter Hi-speed USB Hardware configuration: 85EEA motherboard, Pentium III 700 MHz Test bed computer 56 MB RAM, 40-GB HD, CD (CD-RW), FD, IOGear (or ATEN) USB.0 PCI card (5-port) Software configuration: Windows XP USB cable.5-meter cable [5] -meter cable USB-IF tool on host system HS electrical test tool available from www.usb.org (USBHSET.exe) [] High-speed devices must support the full-speed mode. Consult the Recommended low/full-speed test equipment table for the required test equipment. [] Option 8, enhanced bandwidth, is recommended for the 54855A. Option 5, noise reduction, is recommend for the 80000, 90000 and 90000 X-Series oscilloscopes. [3] A digital signal generator is required when testing receiver sensitivity for devices/hubs. * 8357A (USB.) is obsolete and replaced by 8357B (USB.0) [4] The TDR test was deleted from the Hi-speed Test Procedure (Rev..0), but it is still recommended during development. [5] Not available from Agilent. Refer to www.usb.org for lists of qualified vendors. (Note that four damped adapters are included with the E649A) (The damped adapter part number is 030-630) 9

Recommended Test Equipment (continued) Recommended low-/full-speed test equipment [] With Agilent Infiniium Series or 54830B/D, 5483A/D oscilloscopes Model or part number Description Quantity N546A USB.0 low-/full-/high-speed test option for Infiniium oscilloscopes E646B One SQuIDD (signal quality inrush, drop/droop) test fixture for low-/full-speed USB.0 testing 65A Miniature passive probe for the 5483x Series oscilloscopes 3 N873A Passive probe for the 9000 Series oscilloscopes 3 E697A High-impedance adapter with one 0073C passive probe (for the 90000A Series oscilloscopes) 3 0075A Clip adapter (for each E697A) 3 870-063 Dual lead adapters 3 47B 50-MHz current probe (for 8000, 5483B/D or 3B/D only) N78A and N779A* 50-MHz 30 A current probe and 3-channel power supply USB host system Refer to http://compliance.usb.org/interoperability USB cable 5-meter cable -meter cable USB-IF tool on HS electrical test tool available from www.usb.org (USBHSET.exe) 6 * N774A and N775A are obsolete and replaced with N779A and N78A. USB OTG recommended test equipment Using Agilent Infiniium Series or 54830B/D, 5483A/D Model or part number Description Quantity N547A USB OTG (on-the-go) electrical test fixture N873A Passive probe for the 9000 Series oscilloscopes E697A High-impedance adapter with one 0073C passive probe (for the 90000A Series oscilloscopes) E363 Power supply unit 3440 Digital multimeter (DMM) 8357B* USB/GPIB interface cable 0833A GPIB cable * 8357A is obsolete and replaced by 8357B 0

Ordering Information Infiniium oscilloscope Operating system Software revision USB test option Tests 90000A Series 0.0 or higher N546A or opt. 9 on new scope purchases 9000 Series 0.00 or higher N546A or opt. 9 on new scope purchases 9000 H-Series Windows 7 04.0 or higher N546A or opt. 9 on new scope purchases 90000 X-Series Windows XP Pro 03.00 or higher N546A or opt. 9 on new scope purchases Low-/full-/high-speed Low-/full-/high-speed Low-/full-/high-speed Low-/full-/high-speed Note that free upgrade media for Infiniium oscilloscopes is available for order online at http://www.agilent.com/find/infiniium_software. Agilent Technologies Oscilloscopes Multiple form factors from 0 MHz to > 90 GHz Industry leading specs Powerful applications

www.agilent.com myagilent myagilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. MATLAB is a U.S. registered trademark of The MathWorks, Inc. Pentium is a U.S. registered trademark of Intel Corporation. Three-Year Warranty www.agilent.com/find/threeyearwarranty Agilent s combination of product reliability and three-year warranty coverage is another way we help you achieve your business goals: increased confidence in uptime, reduced cost of ownership and greater convenience. Agilent Advantage Services www.agilent.com/find/advantageservices Accurate measurements throughout the life of your instruments. Agilent Electronic Measurement Group DEKRA Certified ISO 900:008 Quality Management System www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 444 Brazil () 497 3600 Mexico 0800 5064 800 United States (800) 89 4444 Asia Pacific Australia 800 69 485 China 800 80 089 Hong Kong 800 938 693 India 800 99 Japan 00 (4) 345 Korea 080 769 0800 Malaysia 800 888 848 Singapore 800 375 800 Taiwan 0800 047 866 Other AP Countries (65) 375 800 Europe & Middle East Belgium 3 (0) 404 93 40 Denmark 45 45 80 5 Finland 358 (0) 0 855 00 France 085 00 700* *0.5 /minute Germany 49 (0) 703 464 6333 Ireland 890 94 04 Israel 97-3-988-504/544 Italy 39 0 9 60 8484 Netherlands 3 (0) 0 547 Spain 34 (9) 63 3300 Sweden 000-88 55 United Kingdom 44 (0) 8 97 60 For other unlisted countries: www.agilent.com/find/contactus (BP-9-3) Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 0-03 Published in USA, April 30, 03 5989-4044EN